36C25518R0539-0001015.pdf
PDF 1 MB Posted
- Attached to
- 589-334, CO EXPAND PHARMACY AND LOBBY
- Solicitation number
- 36C25518R0539
About this file
36C25518R0539 0001 Drawings Renovate Lobby-Vol 5.pdf
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABBREVIATIONS
OA OUTSIDE AIR
OAG OUTSIDE AIR GRILLE
OAI OUTSIDE AIR INTAKE
OD OUTSIDE DIAMETER
OFM OIL FLOWMETER
OR OPERATING ROOM
NA NOT APPLICABLE
NC NOISE CRITERIA
NC NORMALLY CLOSED
NG NATURAL GAS
NGFM NATURAL GAS FLOWMETER
NO NORMALLY OPEN
NOAA NATIONAL OCEANIC & ATMOSPHERIC
ADMINISTRATION
NOM NOMINAL
NPLV NON-STANDARD PART LOAD VALUE
NPSH NET POSITIVE SUCTION HEAD
NTS NOT TO SCALE
M METER, SI UNIT
M/s METERS PER SECOND
(OR METERS/SECOND)
MA MIXED AIR
MAT MIXED AIR TEMPERATURE
MAU MAKE-UP AIR UNIT
MAV MANUAL AIR VENT
MAX MAXIMUM
MB MIXING BOX
MBH 1000 BTUH
MCA MINIMUM BRANCH CIRCUIT AMPACITY
MER MECHANICAL EQUIPMENT ROOM
MERV MINIMUM EFFICIENCY REPORTING
VALUE
MH MANHOLE
MHP MOTOR HORSEPOWER
MIN MINIMUM
MM MILLIMETER
MOV MOTOR OPERATED VALVE
MPR MEDIUM PRESSURE RETURN
(STEAM CONDENSATE)
MPS MEDIUM PRESSURE STEAM
MRI MAGNETIC RESONANCE IMAGING
MTD MEAN TEMPERATURE DIFFERENCE
MVD MANUAL VOLUME DAMPER
MZ MULTI-ZONE
L LITER
L/h LITERS PER HOUR (OR LITERS/HOUR)
L/m LITERS PER MINUTE (OR
LITERS/MINUTE)
L/s LITERS PER SECOND (OR
LITERS/SECOND)
LAT LEAVING AIR TEMPERATURE
LBS/HR POUNDS PER HOUR
LF LINEAR FOOT (FEET)
LGT LEAVING GLYCOL TEMPERATURE
LH LATENT HEAT
LPG LIQUID PROPANE GAS
LPR LOW PRESSURE RETURN (STEAM
CONDENSATE)
LPRC LOW PRESSURE STEAM RETURN
(CLEAN)
LLHX LIQUID TO LIQUID HEAT EXCHANGER
LPS LOW PRESSURE STEAM
LPSC LOW PRESSURE STEAM (CLEAN)
LSD LINEAR SLOT DIFFUSER
LTCP LOCAL TEMPERATURE CONTROL PANEL
LVG LEAVING
LVR LOUVER
LWT LEAVING WATER TEMPERATURE
kg KILOGRAM kg/HR KILOGRAM PER HOUR kPa KILOPASCAL kW KILOWATT kWh KILOWATT HOUR
J INTENTIALLY LEFT BLANK
I/O INPUT/OUTPUT
IAQ INDOOR AIR QUALITY
IBT INVERTED BUCKET TRAP
ICF IN-LINE CENTRIFUGAL FAN
ICU INTENSIVE CARE UNIT
ID INSIDE DIAMETER
IFB INTEGRAL FACE AND BYPASS
IN INCHES
IN HG INCHES OF MERCURY
IN WC INCH WATER COLUMN
IN WG INCH WATER GAUGE
IN-LB INCH-POUND
IPLV INTERGRATED PART LOAD VALUE
IRH INTRARED HEATER
IS INSECT SCREEN
IU INDUCTION UNIT
IV INLET VANES
ABBREVIATIONS
E EXISTING
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EC EVAPORATIVE COOLER
ECC ENGINEERING CONTROL CENTER
ECU EVAPORATIVE CONDENSER UNIT
EDH ELECTRIC DUCT HEATER
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
EG EXHAUST GRILLE
EGS EMERGENCY GAS SHUTOFF
EGT ENTERING GLYCOL TEMPERATURE
EH EXHAUST HOOD
EJ EXPANSION JOINT
EMD END OF MAIN DRIP (STEAM)
ENT ENTERING
ER EXHAUST REGISTER
ERC ELECTRIC REHEAT COIL
ERP ELECTRIC RADIANT PANEL
ESP EXTERNAL STATIC PRESSURE
ET EXPANSION TANK
ETO ETHYLENE OXIDE
EUH ELECTRIC UNIT HEATER
EWC EVAPORATIVE WATER COOLER
EWT ENTERING WATER TEMPERATURE
EX. EXISTING
F FAHRENHEIT
F&T FLOAT AND THERMOSTATIC
F/SDPR COMBINATION FIRE SMOKE
DAMPER
FA FREE AREA
FC FLEXIBLE CONNECTION
FCU FAN COIL UNIT (4 PIPE)
FCUC FAN COIL UNIT COOLING ONLY
FCUH FAN COIL UNIT HEATING ONLY
FCW FORWARD CURVED WHEEL (FAN)
FD FLOOR DRAIN
FD FIRE DAMPER
FF FINAL FILTER
FHX FLUE GAS/FEEDWATER HEAT
EXCHANGER
FM FLOW METER
FOP FUEL OIL PUMP
FOT FUEL OIL TANK
FOHX FUEL OIL HEAT EXCHANGER
FPM FEET PER MINUTE
FPS FEET PER SECOND
FPTU FAN POWERED TERMINAL UNIT
FR FLOOR REGISTER
FRP FIBER REINFORCED POLYESTER
FS FLOW SWITCH
FSTAT FREEZESTAT
GA GAUGE
GAL GALLONS
GH GRAVITY HOOD
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GS GALVANIZED STEEL
H HUMIDIFER
H&CW HOT & COLD WATER
HAC HOUSEKEEPING AID CLOSET
HB HOSE BIBB
HC HEATING COIL
HD HEAD
HD HOOD
HOA HAND/OFF/AUTOMATIC
HP HEAT PUMP
HP HORSEPOWER
HPDT HIGH PRESSURE DRIP TRAP
HPR HIGH PRESSURE RETURN
(STEAM CONDENSATE)
HPS HIGH PRESSURE SUPPLY
(STEAM)
HRC HEAT RECOVERY COIL
HRD HEAT RECOVERY DEVICE
HRP HYDRONIC RADIANT (CEILING)
PANEL
HRW HEAT RECOVERY WHEEL
HSTAT HUMIDISTAT
HTM HUMIDIFIER TERMINAL
HUM HUMIDIFIER UNIT MOUNTED
HVU HEATING AND VENTILATING UNIT
HW HOT WATER
HWC HOT WATER COIL
HWHC HOT WATER HEATING COIL
HWP HEATING HOT WATER PUMP
HWR HEATING HOT WATER RETURN
HWS HEATING HOT WATER SUPPLY
HWUH HOT WATER UNIT HEATER
HVD HOISTWAY VENT DAMPER
HX HEAT EXCHANGER
HZ HERTZ
FT FEET
FT-LB FOOT-POUND
FTR FIN TUBE RADIATION
FV FACE VELOCITY
ABBREVIATIONS
T & PCV TEMPERATURE AND PRESSURE
CONTROL VALVE
TAB TESTING, ADJUSTING, BALANCE
TD TEMPERATURE DIFFERENCE
TDH TOTAL DYNAMIC HEAD
TDS TOTAL DISSOLVED SOLIDS
TG TRANSFER GRILLE
TP TRAP
TR TOP REGISTER
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
TU TERMINAL UNIT
TWU THRU-WALL UNIT
SA SUPPLY AIR
SAD SOUND ATTENUATING DEVICE
SAT SUPPLY AIR TEMPERATURE
SC SHADING COEFFICIENT
SCFM STANDARD CUBIC FEET PER
MINUTE
SCI SPINAL CODE INJURY
SCR SILICON CONTROLLER RECTIFIER
SCV STEAM CONDENSATE VENT
SD SMOKE DETECTOR
SD SUPPLY AIR DIFFUSER
SD-1 SCHEMATIC DESIGN (SUBMISSION1)
SD-2 SCHEMATIC DESIGN (SUBMISSION2)
SDPR SMOKE DAMPER
SDR SMOKE DAMPER (RETURN)
SDS SMOKE DAMPER (SUPPLY)
SEN SENSIBLE HEAT
SF SUPPLY FAN
SG SUPPLY AIR GRILLE
SH STEAM HUMIDIFIER
SHC STEAM HEATING COIL
SI SQUARE INCHES
SP STATIC PRESSURE
SP GR SPECIFIC GRAVITY
SPD SUPPLY PROCESS AND
DISTRIBUTION
SPRV STEAM PRESSURE REDUCING VALVE
SPS STATIC PRESSURE SENSOR
SQ FT SQUARE FOOT (FEET)
SR SUPPLY AIR REGISTER
SS STAINLESS STEEL
SSHX STEAM TO STEAM HEAT
EXCHANGER
SSR SOLID SEPARATOR
ST STEAM TRAP
SUH STEAM UNIT HEATER
SV STEAM PRESSURE REDUCING
VALVE
SVS STEAM VENT SILENCER
SWHX STEAM TO WATER HEAT
EXCHANGER
R/E RETURN OR EXHAUST
RA RETURN AIR
RAD REFRIGERANT AIR DRYER
RAF RADIO FREQUENCY
RAHX ROTARY AIR HEAT EXCHANGER
RAT RETURN AIR TEMPERATURE
RCCH REMOTE CONDENSER CHILLER
RCU RECIPROCATING CHILLER UNIT
RD REFRIGERANT DISCHARGE
RDS ROOM DATA SHEETS
REA RELIEF AIR
RF RETURN FAN
RG RETURN GRILLE
RH RELATIVE HUMIDITY
RHC REHEAT COIL
RHG REFRIGERANT HOT GAS
RL REFRIGERANT LIQUID LINE
RLA RUN LOAD AMPERE
RO REVERSE OSMOSIS
RPM REVOLUTIONS PER MINUTE
RR RETURN REGISTER
RS REFRIGERANT SUCTION
RTU ROOF TOP UNIT
RV RELIEF VALVE
P PUMP
PA PASCAL
PC PUMPED CONDENSATE
PCF POUNDS PER CUBIC FOOT (FEET)
PD PRESSURE DROP
PEF PROPELLER (TYPE) EXHAUST FAN
PF PRE-FILTER
PG PRESSURE GAGE
PGW PROPYLENE GLYCOL-WATER
(SOLUTION)
PHC PREHEAT COIL
PPM PARTS PER MILLION
PRS PRESSURE REGULATING (VALVE)
STATION
PRV PRESSURE REGULATING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH –
ABSOLUTE
PSIG POUNDS PER SQUARE INCH –
GAGE
PSS PRIMARY SECONDARY SYSTEM
PSV PRESSURE SAFETY VALVE
PTAC PACKAGED TERMINAL AIR
CONDITIONER
ABBREVIATIONS
YR YEAR
W WATTS
WAG WASTE ANETHESIA GAS
Wb WET-BULB (TEMPERATURE)
WC WATER COOLED
WCCH WATER COOLED CHILLER
WCCU WATER COOLED CONDENSING UNIT
WCHP WATER COOLED HEAT PUMPS
WCPU WATER COOLED PACKAGED UNIT
WEF WALL EXHAUST FAN
WF WATER FILTER
WFCV WATER FLOW CONTROL VALVE
WFM WATER FLOWMETER
WFMD WATER FLOW MEASURING DEVICE
WG WATER GAGE
WPD WATER SIDE PRESSURE DROP
V VALVE
VAF VANE-AXIAL FAN
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER (MANUAL
OPPOSED BLADE)
VFD VARIABLE FREQUENCY DRIVE
VHA VETERANS HEALTH ADMINISTRATION
VI VIBRATION ISOLATOR
VIV VARIABLE INLET VANES
VP VACUUM PUMP
VPS VARIABLE PRIMARY SYSTEM
VR VACUUM (STEAM CONDENSATE)
RETURN
VSD VARIABLE SPEED DRIVE
VUH VERTICAL UNIT HEATER
UC UNDER CUT
UC UNIT COOLER
UH UNIT HEATER
UL UNDERWRITERS LABORATORY
URV UPBLAST UNIT VENTILATOR
ABBREVIATIONS
D DAMPER - AUTOMATIC
D-1 OUTDOOR AIR DAMPER
D-2 RETURN AIR DAMPER
D-3 RELIEF AIR DAMPER
DB DECIBELS
Db DRY-BULB TEMPERATURE
DD-1 DESIGN DEVELOPMENT
(SUBMISSION1)
DD-2 DESIGN DEVELOPMENT
(SUBMISSION2)
DDC DIRECT DIGITAL CONTROLS
DEG DEGREE
DF DIFFUSER
DIA DIAMETER
DIW DEIONIZED WATER
DP DEW POINT TEMPERATURE
DP DIFFUSER PLATE
DPA DIFFERENTIAL PRESSURE ASSEMBLY
DPS DIFFERENTIAL PRESSURE SENSOR
DX DIRECT EXPANSION
DXCC DIRECT EXPANSION COOLING COIL
CD-2 CONSTRUCTION DOCUMENTS
(SUBMISSION2)
CENT CENTRIFICAL
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CFT CUBIC FEET
CFP CHEMICAL FEED PUMP
CG CEILING GRILLE
CH CHILLER
CHP CHILLED WATER PUMP
CHW CHILLER WATER
CI CAST IRON
CM CARBON MONOXIDE
CM CUBIC METER
CM/S CUBIC METER PER SECOND
CO CLEAN OUT
CO2 CARBON DIOXODE
COMP COMPRESSOR UNIT
COP COEFFICIENT OF PERFORMANCE
CP CONDENSATE PUMP
CR CEILING REGISTER
CS CONDENSATE STORAGE TANK
CSG CLEAN STEAM GENERATOR
CT COOLING TOWER
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CV CONSTANT VOLUME
CW COLD WATER (POTABLE)
CWCC CHILLED WATER COOLING COIL
CWP CONDENSER WATER PUMP
CWR CHILLED WATER RETURN
CWS CHILLED WATER SUPPLY
B BOILER
BD BUTTERFLY DAMPER
BDD BACKDRAFT DAMPER
BDR BASE BOARD RADIATOR
BFP BACKFLOW PREVENTER
BFT BOILER PLANT FIRE TUBE
BG BOTTOM GRILLE
BHP BRAKE HORSEPOWER
BHW HOT WATER HEATING BOILER
BHX BOILER BLOWDOWN HEAT EXCHANGER
BIW BACKWARD INCLINED WHEEL (FAN)
BMT BONE MARROW TRANSPLANT
BR BOTTOM REGISTER
BSC BIOLOGICAL SAFETY CABINETS
BT BLOWOFF TANK
BTC BLOWOFF TANK CONTROL VALVE
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
BWT BOILER PLANT WATER TUBE
A/E ARCHITECT / ENGINEER
AAHX AIR TO AIR HEAT EXCHANGER
AB AIR BLENDER
AAV AUTOMATIC AIR VENT
ACC AIR COOLED CONDENSER
ACCH AIR COOLED CHILLER
ACCU AIR-COOLED CONDENSING UNIT
ACU AIR CONDITIONING UNIT
ACD AUTOMATIC CONTROL
DAMPER,MODULATING
ACD-TP AUTOMATIC CONTROL
DAMPER,TWO POSITION
AD ACCESS DOOR
AF AFTER FILTER
AFCV AIR FLOW CONTROL VALVE
AFF ABOVE FINISHED FLOOR
AFMD AIR FLOW MEASURING DEVICE
AFW AIR FOIL WHEEL (FAN)
AHU AIR-HANDLING UNIT
AMP AMPERGE
AP ACCESS PANEL
APD AIR PRESSURE DROP
ARI AIR CONDITIONING AND
REFRIGERATION INSTITUTE
AS AIR SEPARATOR
ASME AMERICAN SOCIETY OF MECHANICAL
ENGINEERS
AW AIR WASHER
AXF AXIAL FLOW
C CENTIGRADE (CELCIUS)
CC COOLING COIL
CCD COOLING COIL CONDENSATE
DRAIN
CD CEILING DIFFUSER
CD-1 CONSTRUCTION DOCUMENTS
(SUBMISSION1)
GENERAL NOTES
1. ALL PIPING IN FINISHED ROOMS OR SPACES SHALL BE
CONCEALED IN A FURRED CHASE OR ABOVE THE HARD
SUSPENDED CEILING.
2. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION
OF FACE SHOWN OR INDICATED. DUCT SIZES ARE NET
INSIDE DIMENSIONS.
3. ACCESS PANELS IN HARD SUSPENDED CEILINGS ARE
REQUIRED FOR ALL VALVES, TRAPS, DAMPERS,
CLEANOUTS, CONTROLS, ETC. ACCESS PANELS SHALL
BE FURNISHED AND INSTALLED UNDER THE
ARCHITECTURAL SPECIFICATIONS.
4. TOTAL STATIC PRESSURE NOTED IN THE SCHEDULES
INCLUDES DUCT SYSTEM, TERMINAL UNITS, FILTERS,
COILS, ETC.
5. FOR TYPICAL STEAM AND WATER PIPING CONNECTIONS
TO EQUIPMENT, SEE STANDARD EQUIPMENT DETAILS.
6. DIFFUSER, REGISTER, AND GRILLE SIZES SHOWN ON
FLOOR PLANS ARE NECK SIZES.
7. WATER PIPE CONNECTIONS TO AIR HEATING AND
COOLING COILS SHALL BE MADE TO PROVIDE COUNTER
FLOW BETWEEN WATER AND AIR.
8. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS
FOR EXACT LOCATIONS OF CEILING DIFFUSERS,
REGISTERS, AND GRILLES.
9. SEISMIC PROVISIONS - SEE SPECS. ALL PRESSURES
LISTED ARE GAGE PRESSURE UNLESS OTHERWISE
NOTED.
10.SIZES OF ALL HWS & HWR RUNOUTS TO TERMINAL UNITS
CAN BE FOUND ON THE EQUIPMENT SCHEDULES.
11.THIS CONTRACTOR IS RESPONSIBLE FOR SUBMITTING
FULL COORDINATION AND LAYOUT DRAWINGS PER
SPECIFICATIONS SECTION 230511, 1.4 (G). COORDINATION
SHOULD BE COMPLETED WITH ALL TRADES INCLUDED.
CONSTRUCTION SHALL NOT BEGIN UNTIL COORDINATION
DRAWINGS HAVE BEEN REVIEWED BY THE ENGINEER
AND COR.
12.TAB CONTRACTOR SHALL BALANCE EXISTING GRILLES
USING AIRFLOWS DETERMINED IN TAB PRE-BALANCE
REPORT (SEE DEMO DRAWINGS).
SEISMIC BRACING NOTES
SOME MECHANICAL AND PLUMBING COMPONENTS OF THIS
BUILDING REQUIRE SEISMIC BRACING. IT IS THE
RESPONSIBILITY OF THIS CONTRACTOR AND THE GC TO
ENGAGE A SEISMIC DESIGN ENGINEER TO DETERMINE AND
DESIGN THE REQUIRED BRACING FOR EACH SYSTEM.
SYSTEMS REQUIRING BRACING INCLUDE, BUT ARE NOT
LIMITED TO, THE FOLLOWING:
1. ALL LIFE-SAFETY COMPONENTS INCLUDING FIRE
PROTECTION SYSTEMS.
2. COMPONENTS WEIGHING MORE THAN 400 POUNDS.
3. COMPONENTS WITH A CENTER OF MASS GREATER
THAN 4 FEET ABOVE FLOOR LEVEL AND WEIGHING
MORE THAN 20 POUNDS. (E.G. TERMINAL UNITS).
4. DISTRIBUTION SYSTEMS WEIGHING MORE THAN 5
POUNDS PER FOOT. (E.G. 12x12, 22 GAUGE, SHEET
STEEL DUCTWORK AND CHILLED, HEATING,
DOMESTIC HOT, AND DOMESTIC COLD WATER PIPING
LARGER THAN 1 1/2".
FLEXIBLE CONNECTIONS ARE REQUIRED BETWEEN ALL
COMPONENTS AND ASSOCIATED DUCTWORK, PIPING, AND
CONDUITS.
THE FOLLOWING COMPONENTS ARE NOT REQUIRED TO BE
BRACED:
1. PLUMBING FIXTURES
THE CONTRACTOR SHALL PROVIDE ALL COMPONENT
SUBMITTALS WITH COMPONENT WEIGHTS TO SEISMIC
DESIGN ENGINEER FOR USE IN BRACING DESIGN.
BRACING SHALL BE DESIGNED TO MEET ASCE7 AND NFPA
13 BRACING REQUIREMENTS. REFER TO ASCE7 CHAPTER
13 FOR MORE INFORMATION ON SYSTEMS REQUIRED TO BE
BRACED.
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
MM001
MECHANICAL COVER SHEET
RENOVATE MAIN LOBBY 589-334
04/03/2018 BOH AR
MECHANICAL SHEET INDEX
MM001 MECHANICAL COVER SHEET
MM002 MECHANICAL COVER SHEET
MD101 HVAC DEMOLITION PLAN - FIRST FLOOR
MH101 HVAC FLOOR PLANS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-511 MECHANICAL CONTROL DIAGRAMS
M-601 MECHANICAL SCHEDULES
OVERFLOW
RH
SCH
SH
TH
PS
RC
WB
CSH
SS
LC
M
PIPING SYMBOLS
VACUUM CONDENSATE RETURN
CONDENSATE TRANSFER PUMP SUCTION
CONDENSATE TRANSFER PUMP DISCHARGE
FEEDWATER PUMP DISCHARGE
FEEDWATER PUMP SUCTION
VR
CTPS
CTPD
FWPS
FWPD
FEEDWATER SAMPLE (FROM DEAERATOR)
BOILER WATER SAMPLE
CONTINUOUS BLOWDOWN
CF
FWS
BWS
CBD
BO
CHEMICAL FEED
BOILER BLOWOFF
TUBE CLEANER WATER SUPPLYTC
A
OFL
COMPRESSED AIR
COLD WATER (CITY WATER)
LIQUEFIED PETROLEUM GAS IGNITER FUEL
NATURAL GAS IGNITER FUEL
NATURAL GAS MAIN FUEL
HW
SW
CW
FOR
FOS
LPG(I)
G(I)
G
HOT WATER
SOFTENED WATER
FUEL OIL RETURN
FUEL OIL SUPPLY
RISER CLAMP (TYPE 42)*
FLOOR-SUPPORTED PIPE STAND
CLEVIS-TYPE HANGER
VARIABLE SPRING-TYPE HANGER (TYPE 51)*
ROLLER-TYPE HANGER
TO TRAPEZE EXCEPT WHERE RH ARE INDICATED)
TRAPEZE HANGER (PROVIDE U-BOLT PIPE ATTACHMENT
SPRING CUSHION-TYPE HANGER (TYPE 48 OR 49)*
STANDARD PRACTICE SP-58
SLIDING SUPPORTS (TYPE 35)*
CONSTANT SUPPORT HANGER (TYPE 54, 55, 56)*
WALL BRACKET (TYPE 31, 32, 33)*
* TYPE NUMBERS REFER TO MANUFACTURER'S STANDARDIZATION SOCIETY
DRAWING SYMBOLS
26-SF 3
26-TU-I-I
DETAIL NUMBER
DRAWING NUMBER WHERE SHOWN
SECTION LETTER
TYPICAL UNIT NO.
BUILDING NO. WHERE EQUIPMENT IS LOCATED.
SUPPLY FAN NO. 3 IN BUILDING NO. 26
EQUIPMENT ABBREVIATION (SUPPLY FAN)
ITEM NUMBER (TERMINAL UNIT NO. 1)
ITEM (TERMINAL UNIT SHOWN)
SERVED BY AIR HANDLER UNIT NO. 1
DRAWING NUMBER WHERE DRAWN
BUILDING NO. WHERE EQUIPMENT IS LOCATED
AIR TERMINAL SYMBOLS
FAN POWERED VARIABLE VOLUME
TERMINAL UNIT WITH HEATING COIL.
MB
DOUBLE DUCT MIXING BOX.
TERMINAL UNIT WITH REHEAT COIL
PIPING SYMBOLS
HIGH PRESSURE STEAM CONDENSATE RETURN
HIGH PRESSURE STEAM (60 PSIG AND ABOVE)
HOT WATER HEATING SUPPLY
CONDENSATE PUMP DISCHARGE
LOW PRESSURE STEAM CONDENSATE RETURN
LOW PRESSURE STEAM (15 PSIG AND BELOW)
MEDIUM PRESSURE STEAM CONDENSATE RETURN
MEDIUM PRESSURE STEAM (16 PSIG THRU 59 PSIG)
VENT LINE
SOLAR WATER RETURN
SOLAR WATER SUPPLY
GLYCOL-WATER HEATING RETURN
GLYCOL-WATER HEATING SUPPLY
REFRIGERANT SUCTION
REFRIGERANT HOT GAS
REFRIGERANT LIQUID
CHILLED WATER SUPPLY
CHILLED WATER RETURN
DRAIN LINE
MAKE-UP WATER
CONDENSER WATER RETURN (TO TOWER)
CHILLED GLYCOL-WATER RETURN
CHILLED GLYCOL-WATER SUPPLY
CONDENSER WATER SUPPLY (FROM TOWER)
HOT WATER HEATING RETURN
HPS
HPR
MPS
MPR
LPS
LPR
PC
HWS
HWR
GHS
GHR
V
SWS
SWR
CWR
CHR
GCR
RL
RS
RHG
CWS
CHS
GCS
MW
D
GLYCOL-WATER RUN AROUND SUPPLY
GLYCOL-WATER RUN AROUND RETURNGRR
GRS
X EXISTING PIPE TO BE REMOVED
GENERAL PIPING SYMBOLS
ANCHOR
REDUCER OR INCREASER
DIRECTION OF FLOW
SIDE CONNECTION
ECCENTRIC REDUCER
BOTTOM CONNECTION, 45° OR 90°
TOP CONNECTION, 45° OR 90°
DIRECTION OF PIPE PITCH (DOWN)
UNION
RISE OR DROP IN PIPE
CAPPED OUTLET
PRESSURE GAGE
THERMOMETER
FLOW ELEMENT
FLOAT & THERMOSTATIC TRAP SET INCLUDING
PIPING ACCESSORIES SEE DETAIL
PIPING ACCESSORIES SEE DETAIL
INVERTED BUCKET TRAP SET INCLUDING
FE
PIPE UP
PIPE DOWN
REFRIGERANT SIGHT GLASS
TEST PLUG (PRESSURE/TEMPERATURE)
AUTOMATIC AIR VENT
AV
MANUAL AIR VENT
MV
THERMOSTATIC TRAP SET INCLUDING
PIPING ACCESSORIES SEE DETAIL
QUICK-COUPLE HOSE CONNECTOR
VALVE SYMBOLS
BALL VALVE
GATE VALVE WITH 3/4" HOSE ADAPTER
CHECK VALVE
ANGLE GLOBE VALVE
BUTTERFLY VALVE
MODULATING CONTROL VALVE
TWO POSITION CONTROL VALVE
THREE-WAY MODULATING CONTROL VALVE
AUTOMATIC BALANCING CONTROL VALVE
PRESSURE SAFETY VALVE
GATE VALVE - THREADED/FLANGED
GLOBE VALVE - THREADED/FLANGED
PRESSURE REGULATING VALVE
THREE-WAY TWO POSITION CONTROL VALVE
WYE STRAINER (WITH BALL VALVE & HOSE CONNECTION)
FLEXIBLE CONNECTION
WATER BALANCE DEVICE
MODULATING CONTROL BUTTERFLY VALVE
CIRCUIT SETTER VALVE
GATE VALVE WITH GLOBE-VALVED BYPASS
PLUG VALVE
CONTROL VALVE (CV) - FLOAT-OPERATED
PRESSURE REDUCING VALVE (PRV)
HOSE CONNECTOR
WYE STRAINER WITH VALVED DRAIN AND QUICK-COUPLE
WATER LEVEL CONTROLLER
FLOW METER
DUCTWORK SYMBOLS
LIMIT OF DEMOLITION
(WALL TYPE)
(WALL TYPE)
DN
DN
UP
UP
SUPPLY DUCT (UP & DOWN)
EXHAUST DUCT (UP & DOWN)
ROUND AND SQUARE 4-WAY CEILING DIFFUSERS
SUPPLY TOP REGISTER OR GRILLE (WALL TYPE)
EXHAUST OR RETURN CEILING REGISTER OR GRILLE
EXHAUST OR RETURN BOTTOM REGISTER OR GRILLE
EXHAUST OR RETURN REGISTER OR TOP GRILLE
VANED ELBOW & AIR SPLIT TYPE DUCT TAKE-OFF
CONNECT NEW DUCT TO EXISTING DUCT
D
INCLINED RISE, IN DIRECTION OF AIR FLOW
INCLINED DROP, IN DIRECTION OF AIR FLOW
R
DNUP RETURN DUCT (UP & DOWN)
SQUARE 3-WAY CEILING DIFFUSERS
SQUARE 2-WAY CEILING DIFFUSERS
LINEAR SLOT DIFFUSER
SQUARE 1-WAY CEILING DIFFUSERS
DUCTWORK SYMBOLS
BACK DRAFT DAMPER
BDD
SECTION.)
FC
10x8
FLEXIBLE CONNECTION, EQUIPMENT,
VANED ELBOW (PROVIDE ALL SQUARE OR
RECTANGULAR ELBOWS WITH VANES EVEN IF
SYMBOL IS MISSING)
VANED ELBOW (SHORT RADIUS)
STANDARD RADIUS ELBOW (LONG RADIUS)
NEW DUCT (INSIDE DIMENSIONS: WIDTH x DEPTH)
EXISTING DUCT TO REMAIN
LOUVER (LOUVER SPECIFIED IN ARCHITECTURAL
FIRE DAMPER
FD
VD
DUCT WITH SOUND LINING
FLEXIBLE DUCTWORK (INSULATED)
MANUAL VOLUME DAMPER
EXISTING DUCT TO BE REMOVED
VIBRATION, OR SEISMIC
DUCTWORK SYMBOLS
DUCT MOUNTED COIL
DUCT MOUNTED COIL (HOT WATER OR STEAM COIL)
SUPPLY
RETURN45°
RETURN, NO SPLITTER (45° TAP)
STANDARD BRANCH SUPPLY OR
MANUAL SPLITTER DAMPER
45°
N
2 1
POINT OF CHANGE IN DUCT CONSTRUCTION BY
STATIC PRESSURE CLASS. THE NUMBER ASSIGNS
PRESSURE CLASS (IN. OF WATER) WHICH WILL
ACCOMMODATE MAXIMUM OPERATING PRESSURE
COMBINATION FIRE/SMOKE DAMPER
1/24 IN THE DUCT SUBSECTION. THE SYMBOL CONTINUES
THE ASSIGNMENT UNTIL THE DUCT TERMINATES OR
ANOTHER SYMBOL APPEARS. A "N" SUPERSCRIPT
INDICATES NEGATIVE PRESSURE.
STAINLESS STEEL DUCT
(ELECTRIC)
F/S DPR
AUTOMATIC CONTROL DAMPER MODULATING
AUTOMATIC CONTROL DAMPER TWO POSITION
TERMINAL UNIT SYMBOLS
2'x4' RADIANT CEILING PANEL
2'x2' RADIANT CEILING PANEL
AIR CURTAIN
A
PTAC
A TWU
THRU WALL AIR CONDITIONING UNIT.
UNIT. LETTER INDICATES UNIT SIZE.
WINDOW TYPE AIR CONDITIONING
LETTER INDICATES UNIT SIZE.
UNIT HEATER (VERTICAL)
UNIT HEATER (HORIZONTAL)
CONVECTOR OR RADIATOR (RECESSED)
LETTER INDICATES UNIT SIZE.
FLOOR MOUNTED VERTICAL CABINET FAN COIL UNIT.
FLOOR MOUNTED VERTICAL RECESSED FAN COIL UNIT.
LETTER INDICATES UNIT SIZE.
CONVECTOR OR RADIATOR (WALL HUNG)
A
FCU
FCU
A
INDICATES UNIT SIZE.
FLOOR MOUNTED HEAT PUMP. LETTER
PTACA
(E)10x8
FIRE PROTECTION RISER LOCATION
H4
H7
A
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
MM002
MECHANICAL COVER SHEET
RENOVATE MAIN LOBBY 589-334
04/03/2018 BOH AR
ACA
ACA
(EX)10x10
(E X
)1 x
(E)-130
(EX)10x10
(E)-130
(E)-130(E)-130
(EX)8"ø(EX)8"ø
(EX)12x10
(E)-255 (E)-255 (E)-255
(EX)10x12
(E)-130
(E X
)1 x
(EX)8"ø
(E X
)8 "ø
(E X
)1 "ø
(E X
)1 x
(EX)12x12
(E)-130(E)-130
(EX)10x10
(EX)12x8(E)-130
(E)-130
(EX)8x8
(EX)22x12
(EX)18x12
(E)-130 (E)-130 (E)-130 (E)-130
(E)-255 (E)-255
(E)-255
(E)-255
(E)-255
(E)-255
(E)-255
(E)-130
(E)-130 (E)-130
(E)-130 (EX)8"ø
(EX)8"ø(EX)8"ø
(E X
)8 "ø
(EX)8"ø
(EX)10x10
(EX)14x12
(E X
)2 x
(E)-130
(E)-130
(E)-130
(E)-130
(EX)8x8
2 2
(E)-130
1 1
1 1
1 22
EXISTING TO REMAIN
REMODEL AREA
DEMOLITION PLAN NOTES
1. REMOVE EXISTING DIFFUSERS/GRILLES.
2. REMOVE EXISTING DUCTWORK.
3. REMOVE EXISTING TERMINAL UNIT. DISCONNECT EXISTING
HWS/HWR PIPING FROM TERMINAL BOX BEING REMOVED.
LEAVE FOR CONNECTION TO NEW BOX. REMOVE EXISTING
THERMOSTAT AND CONTROL WIRING ASSOCIATED WITH
TERMINAL UNIT TO BE REMOVED.
4. REMOVE EXISTING DUCT BACK TO EXISTING BRANCH/MAIN
CONNECTION.
GENERAL NOTES
1. TAB CONTRACTOR TO PROVIDE TAB PRE-BALANCE REPORT
FOR ALL EXISTING VAV BOXES, AIR HANDLER UNITS,
EXHAUST FANS OR OTHER AIR MOVING SYSTEM(S)
AFFECTED IN REMODEL AREA. PRE-BALANCE REPORT TO
INCLUDE AIRFLOW FROM ALL TERMINAL UNITS, SUPPLY
DIFFUSERS, RETURN GRILLES AND EXHAUST GRILLES.
2. ALL PIPING IN FINISHED ROOMS OR SPACES SHALL BE
CONCEALED IN A FURRED CHASE OR ABOVE THE HARD
SUSPENDED CEILING.
3. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF
FACE SHOWN OR INDICATED. DUCT SIZES ARE NET INSIDE
DIMENSIONS.
4. ACCESS PANELS IN HARD SUSPENDED CEILINGS ARE
REQUIRED FOR ALL VALVES, TRAPS, DAMPERS,
CLEANOUTS, CONTROLS, ETC. ACCESS PANELS SHALL BE
FURNISHED AND INSTALLED UNDER THE ARCHITECTURAL
SPECIFICATIONS.
5. TOTAL STATIC PRESSURE NOTED IN THE SCHEDULES
INCLUDES DUCT SYSTEM, TERMINAL UNITS, FILTERS, COILS,
ETC.
6. FOR TYPICAL STEAM AND WATER PIPING CONNECTIONS TO
EQUIPMENT, SEE STANDARD EQUIPMENT DETAILS.
7. DIFFUSER, REGISTER, AND GRILLE SIZES SHOWN ON
FLOOR PLANS ARE NECK SIZES.
8. WATER PIPE CONNECTIONS TO AIR HEATING AND COOLING
COILS SHALL BE MADE TO PROVIDE COUNTER FLOW
BETWEEN WATER AND AIR.
9. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS
FOR EXACT LOCATIONS OF CEILING DIFFUSERS,
REGISTERS, AND GRILLES.
10.SEISMIC PROVISIONS - SEE SPECS. ALL PRESSURES LISTED
ARE GAGE PRESSURE UNLESS OTHERWISE NOTED.
11.SIZES OF ALL HWS & HWR RUNOUTS TO TERMINAL UNITS
CAN BE FOUND ON THE EQUIPMENT SCHEDULES.
12.KEEP RETURN AIR GRILLES IN LOBBY ARE COVERED WITH
FILTERS WHILE SPACES ARE UNDER CONSTRUCTION.
REMOVE FILTERS AFTER ALL CONSTRUCTION HAS BEEN
PERFORMED.
13.THIS CONTRACTOR IS RESPONSIBLE FOR SUBMITTING FULL
COORDINATION AND LAYOUT DRAWINGS PER
SPECIFICATIONS SECTION 230511, 1.4 (G). COORDINATION
SHOULD BE COMPLETED WITH ALL TRADES INCLUDED.
CONSTRUCTION SHALL NOT BEGIN UNTIL COORDINATION
DRAWINGS HAVE BEEN REVIEWED BY THE ENGINEER AND
COR.
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
MD101
HVAC DEMOLITION PLAN - FIRST
FLOOR
RENOVATE MAIN LOBBY 589-334
04/03/2018 BOH AR
1/8" = 1'-0"
HVAC DEMOLITION PLAN - FIRST FLOOR
4' 8' 16'
1/8" = 1'-0"
0'
N
1" = 80'-0"
KEY PLAN LEVEL 1
N
GENERAL NOTES
1. ALL PIPING IN FINISHED ROOMS OR SPACES SHALL BE
CONCEALED IN A FURRED CHASE OR ABOVE THE HARD
SUSPENDED CEILING.
2. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION
OF FACE SHOWN OR INDICATED. DUCT SIZES ARE NET
INSIDE DIMENSIONS.
3. ACCESS PANELS IN HARD SUSPENDED CEILINGS ARE
REQUIRED FOR ALL VALVES, TRAPS, DAMPERS,
CLEANOUTS, CONTROLS, ETC. ACCESS PANELS SHALL
BE FURNISHED AND INSTALLED UNDER THE
ARCHITECTURAL SPECIFICATIONS.
4. TOTAL STATIC PRESSURE NOTED IN THE SCHEDULES
INCLUDES DUCT SYSTEM, TERMINAL UNITS, FILTERS,
COILS, ETC.
5. FOR TYPICAL STEAM AND WATER PIPING CONNECTIONS
TO EQUIPMENT, SEE STANDARD EQUIPMENT DETAILS.
6. DIFFUSER, REGISTER, AND GRILLE SIZES SHOWN ON
FLOOR PLANS ARE NECK SIZES.
7. WATER PIPE CONNECTIONS TO AIR HEATING AND
COOLING COILS SHALL BE MADE TO PROVIDE COUNTER
FLOW BETWEEN WATER AND AIR.
8. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS
FOR EXACT LOCATIONS OF CEILING DIFFUSERS,
REGISTERS, AND GRILLES.
9. SEISMIC PROVISIONS - SEE SPECS. ALL PRESSURES
LISTED ARE GAGE PRESSURE UNLESS OTHERWISE
NOTED.
10.SIZES OF ALL HWS & HWR RUNOUTS TO TERMINAL UNITS
CAN BE FOUND ON THE EQUIPMENT SCHEDULES.
11.THIS CONTRACTOR IS RESPONSIBLE FOR SUBMITTING
FULL COORDINATION AND LAYOUT DRAWINGS PER
SPECIFICATIONS SECTION 230511, 1.4 (G). COORDINATION
SHOULD BE COMPLETED WITH ALL TRADES INCLUDED.
CONSTRUCTION SHALL NOT BEGIN UNTIL COORDINATION
DRAWINGS HAVE BEEN REVIEWED BY THE ENGINEER
AND COR.
12.TAB CONTRACTOR SHALL BALANCE EXISTING GRILLES
USING AIRFLOWS DETERMINED IN TAB PRE-BALANCE
REPORT (SEE DEMO DRAWINGS).
EXISTING TO REMAIN
REMODEL AREA
WAITING
EXAM
A125
EXAM
A123
EXAM
A121
PHARM. CARE SVC.
A119A
SILVER TEAM CHECK IN
A119
ELEC/TELE/MECH
A129B
ELEC/TELE/MECH
A129A
(E X
)1 "ø
(EX)10x10
(EX)8"ø
(EX)8"ø
(E X
)1 x
(E X
)8 "ø
(E X
)1 "ø
(EX)10x10(EX)12x10(E X
)2 x
(EX)10x10
(EX)12x12
(E X
)1 "ø
(E X
)8 "ø
(E X
)6 "ø
(EX)8"ø(EX)8"ø
(E X
)8 "ø
(EX)10x10
(E X
)1 x
(EX)16"ø
(EX)14"ø
(EX)8"ø
(EX)8"ø
(E X
)1 x
(E X
)8 "ø
(E X
)6 "ø
(E X
)8 "ø
(E X
)2 x
(EX)8"ø
(EX)8"ø
(EX)10x12
(E X
)1 x
(EX)12x12
(E X
)6 "ø
(EX)8"ø
(E X
)8 "ø
(EX)10x12(EX)10x12
E 1
ACA
B
ACA
B.2
ACA
C
ACA
ACA
11.5
ACA
ACA
10.6
ACA
ACA
ACA
ACA
ACA
6.3
ACA
ACA
5.6
D.1
0.8
LOBBY
C1E3
VALET
C1E34
INFO. DESK
C1E35
VESTIBULE
C1E32
W.C. STOR
E101
LOBBY
C1E3
ENTR. VEST.
E1100
SD-11
"ø
SD-12
SD-12
SD-12
SD-12
RG-23
RG-21
RG-21100
RG-21
RG-21
x
"ø
12"ø 10"ø
8"ø
8"ø
10"ø
"ø
1-T1.19
575 CFM
1-FD-01
1-FD-01
ROI LEGAL
E102E
HBA
E102D
HBA
E102C
HBA
E102C
PRE-REG
E102A
KIOSK
E101
(EX)22x12
(EX)14x12 (E)-255 (E)-255
(E)-255
(E)-255
(E)-255
(E)-255
(E)-255
(E)-130
(E)-130
(E)-130
(E)-130
(E)-130
(E)-130 (E)-130
(EX)18x12
(EX)10x10
(E)-130
(E X
)2 x
(E X
)2 x
10"ø x
MH101
RR-52
RR-52
RR-52
RR-52
RR-52
SD-12
SD-12
SD-11
SD-14
12x12 UP
SD-12
RR-52
RR-52
12x1210x1010x8
"ø
"ø
8x88x8
"ø
8"ø
8"ø 8"ø 8"ø
8"ø
(EX)8x10
(EX)8x8
(EX)13"ø (EX)13"ø
1-A-1
AREA NOT IN SCOPE
AREA NOT IN SCOPE
ADMISSIONS SUPERVISOR
E102H
ADMISSIONS LEAD
E102I
SUPPLY
E102J
HBA
E102F
HBA
E102B
WORK
E102G
PERSONAL EFFECTS
E102K
HALL
E102
CORR
C1A1
CORR
C1E6
CORR.
B116
ADMIN.
B134
OFFICE
B138
OFFICE
B137
JAN
LKR.
B144B
ST. LNGE.
B144
MEN TLT
E108
PAT. REP.
E108B DETAILS CLERK
E108C
FAMILY TLT
E107
WOMEN TLT
E106
CL.
E103
CL.
E104
CL.
E105
TREAT. 4
PT. TLT/SHR.
CORR.
CORR.
TRIAGE
RECEP.
CORR.
112 TRIAGE
SOILED UTIL.
111CLEAN
VERT RM. 2
VERT RM. 3
VERT RM. 1
B.H. EXAM
B.H. TLT.
CHART
112A
OFFICE
E147B
CORR.
C1E8
TRANSCRIPTION OFF.
E144
VEST.
OI&T CLOSET
B144A
ST. TLT
B143
NOURISH.
109A
CORR.
CHECK-IN
A119
PHARM. CARE SVC.
A119A
N. STN./ PHYS. WK.
ENTR. VEST.
Room
EXAM
EXAM
EXAM
CASHIER WINDOWS
TREAT. 3
PAT. INTERVIEW.
B133
PAT. TLT.
B130
HALL
CORR.
CORR.
CORR.
CAP
T
E 1
ACA
B x
EF-57
MH101
750 CFM
736 -0 FIN. FLOOR
0' - 0"
E 1
ACA
A
749-9 1/4 SECOND
FLOOR
13' - 9 1/4"
E 1
ACA
A
736'-0" FIRST FLOOR
736' - 0"
E 10.8
12x12
EF-57
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
MH101
HVAC FLOOR PLANS
RENOVATE MAIN LOBBY 589-334
04/03/2018 BOH AR
N 4' 8' 16'
1/8" = 1'-0"
0'
N
1" = 80'-0"
KEY PLAN LEVEL 1
1/8" = 1'-0"
HVAC PLAN - FIRST FLOOR
1/8" = 1'-0"
HVAC PLAN - ROOF
4' 8' 16'
1/8" = 1'-0"
0'
N
1/4" = 1'-0"
RESTROOM EXHAUST LOOKING EAST
2' 4' 8'0'
1/4" = 1'-0"
W
R
R
2/3W
/3
W
W W
1/2W
/3
W
1/6W
R
W
1/2" 1/2" 1 1/2"
S E
E N
O T
E
SEE NOTE 3
SEE NOTE 2
SEE NOTE 1
W
90°
NTS
DUCTWORK RADIUS ELBOWS
VANE
VANE
NOTE:
1.
2.
THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND.
ALL STANDARD RADIUS ELBOWS CAN BE SUBSTITUTED WITH SHORT RADIUS ELBOWS. ALL
SHORT RADIUS ELBOWS SHALL HAVE VANES. VANES SHALL BE CONSTRUCTED,
SUPPORTED AND FASTENED AS RECOMMENDED BY SMACNA.
R SHALL
EQUAL
OR BE
GREATER
THAN W.
R SHALL
EQUAL
OR BE
GREATER
THAN
1/3W.
R SHALL
EQUAL
OR BE
GREATER
THAN
1/6W.
STANDARD RADIUS OR
LONG RADIUS ELBOW
SHORT RADIUS ELBOW
WITH ONE VANE
SHORT RADIUS ELBOW
WITH TWO VANES
NTS
SUPPLY DUCTWORK TAKE-OFFS
DESIGNER'S NOTES:
1. THE SUPPLY REGISTER TAKE-OFF MAY BE USED FOR UP UP TO 25% OF THE MAIN DUCT CFM.
THE BRANCH DUCT TAKE-OFF MAY BE USED FOR UP TO 15% OF THE MAIN DUCT CFM
ANYTIME AND UP TO 40% WHEN THE MAIN DUCT VELOCITY IS 1000 FPM [5.1 M/S] OR LESS. THE
AIR SPLIT DUCT TAKE-OFF SHALL BE USED IN ALL OTHER CASES AND MAY BE USED AT
ANYTIME.
2. SHOW ALL VOLUME DAMPERS ON FLOOR PLANS.
AIR SPLIT DUCT TAKE-OFF PLAN
VIEW
BRANCH DUCT TAKE-OFF PLAN VIEW
SUPPLY REGISTER TAKE-OFF
PLAN VIEW
AIR
FLOW
AIR
FLOW
A
IR
F L O
W
SUPPLY REGISTER
OR BRANCH DUCT
TURNING VANES
MAIN
SUPPLY
DUCT
SEE FLOOR PLAN FOR
SPLIT DIMENSION
PROVIDE VOLUME
DAMPER
PROVIDE VOLUME
DAMPER
ADJUSTABLE
METAL ROD
OR LINKAGE
TOP REGISTER
MAIN
SUPPLY
DUCT
VOLUME EXTRACTOR; ADJUSTABLE FROM
FULLY CLOSED POSITION TO CFM NOTED
ON FLOOR PLANS
AIR
FLOW
AIR
FLOW
1/4 W OR 4" [100mm] MIN.
AIR
FLOW
MAIN SUPPLY
DUCT
A
IR
F L O
W
NTS
FLEXIBLE DUCT CONNECTIONS
ROUND FLEXIBLE CONNECTION
RECTANGULAR FLEXIBLE CONNECTION
FLANGED
CONNECTION ON FAN
SIDE
WASHER 1-1/2" [40mm] MIN. TO 3" [75mm] MAX.
INSTALLED. 6" [150mm] NOMINAL WITH
MATERIAL TAUT
FLEXIBLE
MATERIAL AS
SPECIFIED
1"x1/8" [25x3mm] DRAW BAND
1"x1/8" [25x3mm] BAND IRON
BOLT ON 4" [100mm] CENTERS
5/16" [8mm] FLANGE
DUCT
SHEET METAL SCREWS ON
12" [300mm] CENTERS
RIVET ON 4"
[100mm] CENTERS
SHEET METAL AS
SPECIFIED FOR
DUCTWORK.
1"x1/8" [25x3mm] BAND IRON
BOLT ON 4" [100mm] CENTERS
1" [25mm] FLANGE & HEMALTERNATE
POSITION
OF BOLT 1 1/2" [40mm]
POCKET SLIP
DUCT
SHEET METAL AS
SPECIFIED FOR
DUCTWORK.
[15mm] [15mm] [40mm]
1 1/2" [40mm] MIN. TO 3" [75mm] MAX.
INSTALLED. 6" [150mm] NOMINAL WITH
MATERIAL TAUT
FLANGED
CONNECTION
ON FAN SIDE
WASHER
FLEXIBLE MATERIAL
AS SPECIFIED
NTS
DUCT CONNECTIONS - AIR TERMINAL UNITS
NOTE:
1.
2.
3.
4.
5.
6.
RIGID STRAIGHT TERMINAL UNIT INLET LENGTH SHALL BE A
MINIMUM OF 3 TIMES THE DIAMETER OF INLET
A FLEXIBLE AIR DUCT CONNECTOR IS NOT MANDATORY FOR INLET TO THIS
BOX, BUT ALLOWED TO ACCOMMODATE MINOR OFFSETS. MAXIMUM LENGTH
3'-0" [900mm].
A BRANCH DUCT SERVING AN INDIVIDUAL BOX MAY BE THE SAME SIZE AS THE
BOX INLET, PROVIDED THE EQUIVALENT LENGTH OF THE BRANCH DUCT, AS
SHOWN, DOES NOT EXCEED 10 FEET (3 METERS). FOR LONGER LENGTHS,
INCREASE THE DUCT SIZE AND PROVIDE A DUCT TRANSITION TO MAINTAIN
THE DUCT STATIC PRESSURE DROP AT OR BELOW 0.2"/100' [1.64Pa/m].
FLEXIBLE AIR DUCT CONNECTORS, WHEN USED FROM TERMINAL UNIT SUPPLY
AIR DUCT TO DIFFUSER, SHALL NOT EXCEED 5'-0" [1500mm]. USE RIGID
ELBOWS FOR CHANGE OF DIRECTION GREATER THAN 45°.
COMPONENT ARRANGEMENT MAY VARY BY MANUFACTURER. PROVIDE
INSULATION W/VAPOR BARRIER FOR CONNECTING DUCT SECTIONS.
USE OF THE FLEXIBLE AIR DUCT CONNECTORS ARE NOT PERMITTED FOR THE
DEDICATED AHU SERVING THE SURGICAL SUITE.
AIR TERMINAL UNIT
(CV OR VAV)
REHEAT COIL
SOUND
ATTENUATOR SEE
EQUIPMENT
SCHEDULE
FLEXIBLE AIR DUCT
CONNECTOR. SEE DETAIL
DIFFUSER (TYP.)
SEE SPECIFICATIONS FOR
CLAMPS AND SEALANT (TYP.)
SEE NOTE 5
NTS
VOLUME DAMPER DETAIL
NOTE:
1.
2.
DELETE INSULATION STAND-OFF ON DUCTWORK WITHOUT EXTERIOR INSULATION.
DETAIL SHOWS SINGLE BLADE DAMPER. DAMPER INSTALLATION SHALL BE SIMILAR FOR
MULTI-BLADE DAMPERS & ROUND DAMPERS.
INSULATION SEE
SPECIFICATION
DAMPER BLADE
1/8" [6mm]
CLEARANCE
ALL AROUND
OUTSIDE END BEARING
INSIDE END BEARING
HANDLE WITH
LOCKING
QUADRANT
INSULATION STAND-OFF
1/2" [15mm] ROUND
ROD PIN
DUCT
STIFFEN BLADE
AS REQUIRED
SIDE ELEVATION SECTION
SECTION "A-A"
"B" "B"
ACCESS PANEL AND DOOR DETAIL
NTS
NOTES:
1. LATCHES SHALL BE OF THE WEDGE TYPE TO CLOSE DOORS TIGHTLY.
2. HINGES ON THE ACCESS DOORS SHALL HAVE NON-CORROSIVE PINS.
3. SEE SMACNA 2005, FIGURE 9-15
ACCESS PANEL
ACCESS DOOR
CASING
GASKET
HANDLE INSIDE
FLEXIBLE
WASHER
FACTORY
FABRICATED
LATCH
SECTION "B-B"
INSULATION
DUCT
GASKET
INSULATION
INSULATION
"A"
"A"
NTS
FIRE DAMPER INSTALLATION
SECTION THRU
NOTE:
1.
2.
3.
4.
A VERTICAL DAMPER IS SHOWN. HORIZONTAL DAMPER INSTALLATION, 1S SIMILAR. FOLLOW
DAMPER MANUFACTURER'S INSTRUCTIONS, INCLUDING FASTENER OPTIONS AND GAGES FOR
SLEEVE AND PERIMETER ANGLES. FIRE DAMPERS MUST BE INSTALLED IN THE PARTITION OR
FLOOR AND NOT OUTSIDE THE PENETRATION.
GALVANIZED SLEEVE: GAGE NOT LESS THAN CONNECTING DUCT. FASTEN SLEEVE TO DAMPER
FRAME AND TO PERIMETER ANGLES.
PERIMETER ANGELS: GALVANIZED STEEL, NOT LESS THAN 1 1/2"x1 1/2" [40x40mm], 14 GAGE, TO
PROVIDE 1" [25mm] MINIMUM OVERLAP OF OPENING ON ALL 4 SIDES.
BREAKAWAY DUCT CONNECTION: CONTRACTOR'S OPTION OF TYPES SHOWN IN SMACNA.
ACCESS PANELS: SIZE AND LOCATION TO PERMIT SERVICING THE FUSIBLE LINK OR LINKS.
SLEEVE, NOTE 2
DUCT
CONNECTION
NOTE 4
DAMPER,
NOTE 1
DAMPER COLLAR
EXTENSION INTEGRAL
PART OF SLEEVE
SLEEVE, NOTE 2
NOTE 6FIRE BARRIER
PARTITION OR CHASE
TYPICAL DUCT
INSULATION
PERIMETER ANGLE, NOTE 3 (NOTE
FASTENED TO PARTITION)
ACCESS
PANEL
NOTE 5
[2 m m
PITOT TEST CONNECTIONS
NTS
NOTE:
1.
2.
PROVIDE IN CHILLED WATER MAIN AND IN CONDENSER WATER MAIN.
LOCATE PILOT TUBE TAPS 20 PIPE DIAMETERS DOWNSTREAM AND 10 PIPE
DIAMETERS UPSTREAM FROM THE NEAREST PIPE FITTING.
EITHER TOP OR SIDE LOCATION. BOTH ARE NOT REQUIRED AT SAME
LOCATION.
PLUG
1 1/2" [40mm]
FULL PORT BALL
VALVE
1 1/2" DIAMETER x 2" LONG [40x50mm] PIPE
1 1/2" [40mm] FULL
PORT BALL VALVE
PLUG
WELD (TYP)
NTS
EXHAUST OR RETURN BRANCH DUCTWORK
MAIN EXHAUST OR RETURN
PLAN VIEW
AIR
FLOW AIR
FLOW
PROVIDE VOLUME DAMPER
AT EACH BRANCH DUCT
1/4W OR 4" [100mm]
MIN.
BRANCH DUCT
VD
NTS
FROM STRUCTURE
SAME AS DIFFUSER
INLET: 5'-0" MAX
FLEXIBLE DUCT SIZE
LENGTH.
12"
CEILING
SUPPORT SADDLE
VOLUME DAMPER W/
LOCKING QUADSADDLE
SHEET METAL
CONICAL OUTLET
BRANCH DUCT
FOR CHANGE OF
DIRECTION GREATER
USE RIGID ELBOWS
THAN 45°
[300mm]
FLEXIBLE AIR DUCT CONNECTOR
SEE SPECIFICATIONS FOR CLAMPS
AND SEALANT (TYP.)
TYPICAL
DIFFUSER OR
REGISTER IN
LAY-IN CLG.
THERMAL INSULATION
SEE SPECIFICATIONS
NTS
STEEL EXPANSION SHIELD FOR EXISTING
CONSTRUCTION AND INSERTS FOR NEW
CONSTRICTION THIS TYPE SHALL BE USED
ONLY IN SLABS OR BEAMS OF 4" [100mm]
MIN DEPTH
3/8" [10mm] MIN DIA EXPANSION BOLTS FOR
EXISTING CONSTRUCTION AND INSERTS
FOR NEW CONSTRUCTION
CONCRETE
FLOOR SLAB
CLIP
ANGLE
NUTS & WASHERS
3/8" [10mm] MIN DIA
HANGER RODS
FOR PIPES UNDER 2" [50mm] IN SIZE USE 1 1/2"x1 1/2"x1/4" [40x40x6.4mm] ANGLE. ALL PIPES 2" [50mm] & LARGER USE 3"x3"x1/4" [75x75x6.4mm]
ANGLE
TURNBUCKLE
3/8" [10mm] MIN DIA
HANGER RODS
3/8" [10mm] MIN DIA
INSERTS NEW
CONSTRUCTION ONLY.
SECURING HANGER RODS IN CONCRETE
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
M-501
MECHANICAL DETAILS
W
W1
"D"
45°M A
X
NTS
NOTE:
NOT REQUIRED FOR AIR
TERMINAL UNITS.
EQUIPMENT WEIGHT 250 LBS.
[114KG] OR LESS
SEISMIC BRACING FOR LIGHT SUSPENDED
EQUIPMENT
FLOOR MOUNT EQUIPMENT RESTRAINED BY
RESILIENT PADS (TYPE DS)
FLOOR
EQUIPMENT BASE ANCHOR BOLT
NEOPRENE WASHER &
SLEEVE
BONDED STEEL
PLATE
RESILIENT PAD
HANGER
ROD (TYP)
CROSS BRACING RODS ALL
FOUR SIDES
LOCK NUTS
(TYP)
CLAMP
SEISMIC BRACING FOR EQUIPMENT
NTS
COIL
TEST PLUG (TYP.)
REDUCER, IF REQUIRED
WATER RETURN
MANUAL AIR VENT
UNION CONNECTIONS (TYP.)
WATER SUPPLY
TERMINAL UNIT WATER COILS - PIPING CONNECTIONS
SHUT OFF VALVE
DRAIN WITH HOSE
CONNECTION
MV
MODULATION CONTROL VALVE
NTS
DUCTWORK SQUARE VANE ELBOWS
NOTE:
1.
2.
3.
4.
ALL VANE ELBOWS SHALL BE CONSTRUCTED AND INSTALLED AS DETAILED BY SMACNA.
WHEN W1 DOES NOT EQUAL W2, VANE SHALL BE SINGLE THICKNESS VANE TYPE REGARDLESS OF W
DIMENSION.
ALL SINGLE THICKNESS VANES SHALL HAVE A 2" [50mm] RADIUS, 1 1/2" [40mm] MAXIMUM SPACE BETWEEN
VANES AND A 3/4" [20mm] TRAILING EDGE.
WHEN W EQUALS W2 AND W1 IS GREATER THAN 20" [500mm] VANES SHALL BE DOUBLE VANE TYPE.
NTS
SUPPLY DUCT TAKEOFF - AIR TERMINAL UNIT
RIGID DUCT TO AIR TERMINAL UNIT.
ROUND SHEET METAL DUCT.
MAIN SUPPLY
PLAN VIEW
NTS
ROUND DUCT HANGERS
2500 [1133]
1320 [598]
420 [190]ONE 1 [25] x 18 GA STRAP36 [900]
TWO 1/2 [13]∅ RODS
TWO 3/8 [10]∅. RODS
ONE 1 [25] x 16 GA STRAP
84 [2100]
60 [1500]
50 [1250] 700 [317]
ONE 1 [25] x 22 GA STRAP
QUANTITY/SIZEMAX. DUCT ∅
26 [650]
HANGER STRAPS OR RODS
MAX. LOAD
LBS. [kg]
260 [119]
MAX.
144 [3600]
IN. [mm]
SPACING
IN. [mm] IN. [mm]
144 [3600]
144 [3600]
144 [3600]
144 [3600]
NOTE:
TABULATED DATA FROM SMACNA ALLOWS FOR
DUCT REINFORCING AND INSULATION, BUT NO
EXTERNAL LOAD.
BAND
OVER 50"
[1250mm]∅
HANGER RODS
BAND OF SAME SIZE
AS HANGER STRAP
LOAD RATED
FASTENERS
50" [1250mm]∅ &
UNDER
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
M-502
MECHANICAL DETAILS
CONTROLS SYMBOLS
T ROOM THERMOSTAT/TRANSMITTER - WALL MOUNT
TT TEMPERATURE TRANSMITTER
M ROOM HUMIDISTAT (MOISTURE)/TRANSMITTER - WALL MOUNT
MT MOISTURE (HUMIDITY) TRANSMITTER
PT PRESSURE TRANSMITTER
TT TEMPERATURE TRANSMITTER, AVERAGING ELEMENT
FT FLOW TRANSMITTER
IT CURRENT TRANSMITTER
CT CONDUCTIVITY TRANSMITTER
SPS STATIC PRESSURE SENSOR
SD SMOKE DETECTOR
PDT PRESSURE DIFFERENTIAL TRANSMITTER
KR LOCAL RECORDING TIME CLOCK (RUNTIME)
TSL TEMPERATURE SWITCH, LOW (FREEZESTAT)
HS HAND SWITCH (HAND-OFF-AUTO SWITCH)
ZC VALVE OR DAMPER POSITION CONTROLLER
LC LEVEL CONTROLLER
LT LEVEL TRANSMITTER
PDS PRESSURE DIFFERENTIAL SWITCH
TSH TEMPERATURE SWITCH, HIGH (FREEZESTAT)
CONTROLS SYMBOLS
LENGTH IN DUCT WHEN SPACE PERMITS.)
A
TEMPERATURE SENSING ELEMENT FOR
TRANSMITTING TEMPERATURE TO EMCS
(PROVIDE 12 INCHES [200mm] MINIMUM
SENSOR WITH AVERAGING ELEMENT TO TRANSMIT
TEMPERATURE TO EMCS
MOTOR STARTER
M ELECTRIC OPERATED CONTROL DAMPER/OR VALVE
CONTROLS SYMBOLS
EPT ELECTRONIC TO PNEUMATIC TRANSDUCER
AT CARBON DIOXIDE TRANSMITTER
CARBON MONOXIDE TRANSMITTER
CO2
AT
CO
OCCUPANCY SENSORAT
OC
LTCP LOCAL TEMPERATURE CONTROL PANEL
HVAC HVAC CONTROL PANEL
ECC
INTEGRATE CONTROL POINT ON REMOTE GRAPHICS
WORKSTATION AT ENERGY CONTROL CENTER
TC TEMPERATURE CONTROLLER. SEE SEQUENCE OF OPERATION
VSMC VARIABLE SPEED MOTOR CONTROLLER
PC PRESSURE CONTROLLER. SEE SEQUENCE OF OPERATION
SC SPEED CONTROLLER. SEE SEQUENCE OF OPERATION
FC FLOW CONTROLLER. SEE SEQUENCE OF OPERATION
PSH PRESSURE SWITCH HIGH
FSH FLOW SWITCH HIGH
PSL PRESSURE SWITCH LOW
KC TIME CLOCK CONTROLLING EQUIPMENT ON A SCHEDULE
FSL FLOW SWITCH LOW
MC MOTOR CONTROLLER
TRIDIUM\ AX
EXISTING
OPERATOR
TERMINAL
EXISTING BACNET
ENGINEERING CONTROL
CENTER
ECC
EXISTING
NTS
BACNET SYSTEM ARCHITECTURE
NETWORK
BACNET
BUILDING
CONTROLLER
(B-BC)
B-ASC
ETHERNET COMMUNICATION
B-ASC B-ASC
B-ASC
B-ASC
B-ASC
B-ASC
B-ASC
B-ASC
B-AACB-AAC B-AAC
BACNET
BUILDING
CONTROLLER
(B-BC)
BACNET
BUILDING
CONTROLLER
(B-BC)
MSTP COMMUNICATION
(TYPICAL)
EXISTING CONTROLLER PROTOCOL
INSTALL NEW GATEWAY
FOR COMMUNICATION
WITH EXISTING CONTROL
SYSTEM.
B-ASC
EXIST.
GLOBAL
EXIST.
CONTROLLER
B-ASC
EXIST.
B-ASC
EXIST.
B-ASC
EXIST.
B-ASC
EXIST.
BACNET
GATEWAY
NOTES:
1. EXISTING CONTROLLERS TO REMAIN.
2. INSTALL NEW BACNET GATEWAY OR PANEL WITH FULL COMMUNICATION TO
EXISTING
CONTROLLERS.
3. INSTALL NEW BACNET COMMUNICATION NETWORK.
4. INSTALL NEW CONTROLLERS (B-AAC/B-ASC) AS REQUIRED.
5. NEW CONTROL PANEL TO BE LOCATED IN CLOSET B340. COORDINATE POWER
AND DATA REQUIREMENTS WITH EC.
NTS
HWS
HWR
V-2ROOM THERMOSTAT/SENSOR
WALL MOUNTED
48" [1200mm] AFF.
ROOM THERMOSTAT/SENSOR
WALL MOUNTED
48" [1200mm] AFF.
VARIABLE VOLUME AIR TERMINAL UNIT CONTROL DIAGRAM
NO SUPPLEMENTAL HEATING WITH SUPPLEMENTAL HEATING
A
IR
F
LO
W (C
F M
ROOM TEMPERATURE (°F)
HEATING
MINIMUM
VAV BOX CONTROL SEQUENCE
SP
TU
RHCHWS
HWR
V-1
REHEAT
COIL
AIR
TERMINAL
UNIT
AIR FLOW
TE
ATU
CONTROLLERPC
TE
TU
RHCHWS
HWR
V-1
REHEAT
COIL
AIR
TERMINAL
UNIT
AIR FLOW
TE
ATU
CONTROLLER
PC
TE
A
IR
F
LO
W (C
F M
ROOM TEMPERATURE (°F)
HEATING
MINIMUM
SP
A
IR
F
LO
W (C
F M
ROOM TEMPERATURE (°F)
HEATING
MINIMUM
SP
A
IR
F
LO
W (C
F M
ROOM TEMPERATURE (°F)
HEATING
MINIMUM
NO DEADBAND
VAV BOX CONTROL SEQUENCE
W/DEADBAND
VAV BOX CONTROL SEQUENCE
NO DEADBAND
VAV BOX CONTROL SEQUENCE
W/DEADBAND
SUPPLEMENTAL
HEAT
SP
FE
100% 100%
100% 100%
REHEAT FLOW
VAV A
IR
F
LO
W
VA
V
AI
R
FL
O
W
VAV A
IR
F
LO
W
VA
V
AI
R
FL
O
W
REHEAT FLO
W
REHEAT FLOW
SUPP FLOW
REHEAT FLO
W
SUPP FLO
W
A. UPON FALL IN SPACE TEMPERATURE THE
VAV DAMPER WILL MODULATE TO MINIMUM
POSITION.
B. UPON FURTHER DROP IN SPACE
TEMPERATURE VALVE V-1 WILL MODULATE
TO MAINTAIN SET POINT + .5° F. THE
ADJUSTABLE TOLERANCE OF + .5° F HAS
BEEN SELECTED TO PREVENT VALVE
HUNTING
C. THE REVERSE SHALL OCCUR ON THE RISE
IN SPACE TEMPERATURE.
A. SET POINTS SHALL BE SET AS FOLLOWS:
COOLING 75°F (ADJ)
HEATING 70°F(ADJ)
DEADBAND OF 5° F BETWEEN HEATING AND
COOLING SET POINTS WILL BE MAINTAINED.
B. UPON FALL IN SPACE TEMPERATURE THE
VAV DAMPER WILL MODULATE TO MINIMUM
POSITION.
C. UPON FURTHER DROP IN SPACE
TEMPERATURE VALVE V-1 WILL MODULATE
TO MAINTAIN SET POINT + .5° F. THE
ADJUSTABLE TOLERANCE OF + .5° F HAS
BEEN SELECTED TO PREVENT VALVE
HUNTING
D. THE REVERSE SHALL OCCUR ON THE RISE
IN SPACE TEMPERATURE.
A. UPON FALL IN SPACE TEMPERATURE THE
VAV DAMPER WILL MODULATE TO MINIMUM
POSITION.
B. UPON FURTHER DROP IN SPACE
TEMPERATURE VALVE V-1 WILL MODULATE
TO MAINTAIN SET POINT + .5° F. THE
ADJUSTABLE TOLERANCE OF + .5° F HAS
BEEN SELECTED TO PREVENT VALVE
HUNTING
C. VALVE V-2 SHALL BE ENABLED WHEN
OUTSIDE AIR FALLS BELOW 40° F (ADJ)
AND VALVE V-1 HAS BEEN MODULATED
OPEN ABOVE 30% (ADJ). VALVE V-2
SHALL MAINTAIN SET POINT + .5° F. THE
ADJUSTABLE TOLERANCE OF + .5°F HAS
BEEN SELECTED TO PREVENT VALVE
HUNTING. THE REVERSE SHALL OCCUR ON
A RISE IN SPACE TEMPERATURE.
A. SET POINTS SHALL BE SET AS FOLLOWS:
COOLING 75°F (ADJ)
HEATING 70°F(ADJ)
DEADBAND OF 5° F BETWEEN HEATING AND
COOLING SET POINTS WILL BE MAINTAINED.
B. UPON FALL IN SPACE TEMPERATURE THE
VAV DAMPER WILL MODULATE TO MINIMUM
POSITION.
C. UPON FURTHER DROP IN SPACE
TEMPERATURE VALVE V-1 WILL MODULATE
TO MAINTAIN SET POINT + .5° F. THE
ADJUSTABLE TOLERANCE OF + .5° F HAS
BEEN SELECTED TO PREVENT VALVE
HUNTING
D. VALVE V-2 SHALL BE ENABLED WHEN
OUTSIDE AIR FALLS BELOW 40° F (ADJ)
AND VALVE V-1 HAS BEEN MODULATED
OPEN ABOVE 30% (ADJ). VALVE V-2
SHALL MAINTAIN SET POINT + .5° F. THE
ADJUSTABLE TOLERANCE OF + .5°F HAS
BEEN SELECTED TO PREVENT VALVE
HUNTING.
E. THE REVERSE SHALL OCCUR ON THE RISE
IN SPACE TEMPERATURE.
FE
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
M-511
MECHANICAL CONTROL DIAGRAMS
AIR DEVICE SCHEDULE (RETURN/EXHAUST)
MARK TYPE
AIR FLOW
MAX APD
MOUNTING
PANEL/FRAME SIZE NECK SIZE
NC DAMPER FINISH REMARKSMIN MAX
CFM [L/s] CFM [L/s] IN WG [Pa] IN x IN [mm x mm] IN x IN [mm x mm]
RG-21 PERFORATED 60 28 100 47 0.088 22.000 CEILING 24 X 24 [ 600 x 600 ] 6 DIAM [ 152 DIAM ] 13 NONE WHITE -----
NOTE
PROVIDE SQUARE TO ROUND ADAPTER.
RG-23 PERFORATED 170 80 250 120 0.088 22.000 CEILING 24 X 24 [ 600 x 600 ] 10 DIAM [ 254 DIAM ] 14 NONE WHITE -----
RR-52 RETURN REGISTER 125 59 330 160 0.078 20.000 CEILING 12 X 12 [ 305 x 305 ] 10 X 10 [ 254 X 254 ] 15 NONE WHITE -----
FAN SCHEDULE
MARK LOCATION
AREA AND/OR
BLDG SERVED
SYSTEM AND/OR
SERVICE
AIR FLOW TSP
FAN MOTOR ELECTRICAL
CONTROL
SEQUENCE
REMARKS
TYPE WHEEL CLASS
ARRANGEMENT, ROTATION, AND
DISCHARGE
DIAMETER MIN % EFF
DRIVE
FAN MAX
RPM
NOMINAL POWER
VOLT PHASE RPM
SPEED CONTROL
CFM [L/s] IN [Pa] IN [mm] BHP HP [kW]
EF-57 ROOF LOBBY RR'S EXHAUST 750 [354] 0.25 [63] CENTRIFIGUAL - UPBLAST, SIDE INLET VENT SET 7.67" [ 195 ] 30% DIRECT 1140 0.30 0.5 [0.37] 120 1 1140 1- # 1
REMARKS
1. PROVIDE UNIT WITH ROOF CURB, BIRD SCREEN & BACK DRAFT DAMPER.
A. EXHAUST FAN SHALL CONTINUOUSLY OPERATE AND SHALL TIE INTO EXISTING BMS SYSTEM.
NOTE:
ALL SELECTIONS ARE BASED ON AN ALTITUDE OF 758 FT.
A
HVAC DESIGN DATA
DESIGN CONDITIONS
SUMMER WINTER
LOWEST AVERAGE
ANNUAL DEWPOINT
TEMP WET BULB TEMP
% HUMIDITY
TEMP DEWPOINT TEMP
% HUMIDITY
°F [°C] °F [°C] °F [°C] °F [°C] °F [°C]
OUTDOOR DESIGN CONDITIONS
91.6 33.1 75.9 24.4 49 1.3 -17.1 0 -17.8 NA -5.8 -21
INDOOR AREA DESIGN CONDITIONS
CORRIDOR 75 23.9 62 16.7 50 70 21.1 53.9 12.2 30
TOILETS - INTERIOR NA NA NA NA NA NA NA NA NA NA
LOUNGE 75 23.9 62 16.7 50 70 21.1 52.9 11.6 30
AIR DEVICE SCHEDULE (SUPPLY)
MARK TYPE
AIR FLOW
MAX APD
MOUNTING
PANEL/FRAME SIZE NECK SIZE
NC DAMPER FINISH REMARKSMIN MAX
IN x IN [mm x mm] IN [mm ]
CFM [L/s] CFM [L/s] IN WG [Pa]
SD-11 LOUVERED FACE 40 19 100 76 0.080 20 CEILING 24 x 24 [ 600 x 600 ] 6 ø [152 ø] 25 NONE WHITE ----
SD-12 LOUVERED FACE 70 33 280 130 0.100 25 CEILING 24 x 24 [ 600 x 600 ] 8 ø [203 ø] 25 NONE WHITE -----
SD-14 LOUVERED FACE 160 76 470 220 0.080 20 CEILING 24 x 24 [ 600 x 600 ] 12 ø [305 ø ] 22 NONE WHITE -----
NOTES
1. SEE FLOOR PLAN FOR THROW PATTERN. 4-WAY TYPICAL UNLESS OTHERWISE NOTED.
2. SEE DETAIL FOR DAMPER IN BRANCH DUCT SERVING EACH DIFFUSER.
3. PROVIDE SQUARE TO ROUND ADAPTER.
SD-63 GRILLE 125 71 300 140 .090 23 DUCT MOUNTED 10 x 10 [254 x 254] 18 NONE WHITE -----12 x 12 [305 x 305]
FIRE DAMPER SCHEDULE
MARK LOCATION
SYSTEM
AND/OR
SERVICE
FAN SYSTEM
DUCT SIZE
DUCT PRESSURE
CLASS REMARKS
IN [mm] IN WG [Pa]
1-FD-01 CORR. EXIST. 12" x 10" 304 x 254 2" 498 1-1/2 HR. RATING
AIR TERMINAL UNIT SIZING SCHEDULE
SIZE
MIN ALLOWABLE AIR
FLOW
MAX ALLOWABLE AIR
FLOW
DUCT INLET SIZE
MAX APD
MAXIMUM SOUND POWER LEVEL (Re: 10 -12 WATTS) FOR BOX
DISCHARGE AT MAXIMUM INLET DUCT STATIC HOT WATER HEATING COIL
REMARKS
OCTAVE BANDS EAT EWT FLOW MAX WPD
PIPE RUNOUT SIZE TO
COIL
CFM [L/s] CFM [L/s] IN [mm] IN WG [Pa] 2 3 4 5 6 7 °F [°C] °F [°C] GPM [L/m] FT [kPa] IN [mm]
A 60 28 170 80 4 100 0.4 100 69 65 58 52 51 47 55 13 140 60 0.5 1.9 3 9 0.75 19 ----
B 90 42 260 120 5 130 0.4 100 69 63 59 52 51 47 55 13 140 60 0.5 1.9 3 9 0.75 19 ----
C 130 61 380 180 6 150 0.4 100 69 67 61 55 52 49 55 13 140 60 0.7 2.7 4 12 0.75 19 ----
D 160 76 490 230 7 180 0.4 100 70 68 63 57 53 49 55 13 140 60 0.7 2.7 4 12 0.75 19 ----
E 230 110 680 320 8 200 0.4 100 71 68 59 53 51 47 55 13 140 60 1 3.8 3 9 0.75 19 ----
F 270 130 790 370 9 230 0.4 100 71 69 60 54 51 47 55 13 140 60 1.5 5.7 4 12 0.75 19 ----
G 350 170 1050 500 10 250 0.4 100 74 68 61 57 54 52 55 13 140 60 1.5 5.7 4 12 0.75 19 ----
H 500 240 1500 710 12 300 0.4 100 73 69 64 59 57 53 55 13 140 60 2.5 9.5 3 9 0.75 19 ----
I 750 350 2250 1100 14 350 0.4 100 73 68 65 61 61 59 55 13 140 60 3.5 13 4 12 0.75 19 ----
J 1000 470 3000 1400 16 400 0.4 100 73 68 66 60 58 55 55 13 140 60 4.5 17 4 12 1 25 ----
NOTES
1. INLET STATIC BASED ON ARI 885-98.
2. THIS SCHEDULE IS USED WITH THE TERMINAL UNIT SCHEDULE.
3. CONTROL SEQUENCE SHALL BE AS INDICATED ON THE AIR TERMINAL UNIT SCHEDULE.
4. PROVIDE SOUND ATTENUATION AFTER-SECTION AS REQUIRED TO MEET ROOM NC LEVEL.
SINGLE DUCT AIR TERMINAL UNIT SCHEDULE
MARK LOCATION
AREA AND/OR
ROOM SERVED SYSTEM AIR
HANDLING
SIZE
AIR FLOW ADDITIONAL SOUND
ATTENUATION REQUIRED CONTROL TYPE CONTROL SEQUENCE REHEAT PERIMETER SUPPLEMENTAL
HEAT LINK REMARKSMAX MIN
CFM [L/s] CFM [L/s] HW ELEC NONE
1-T1.19 G 575 271 300 142 NONE VAV 5 DEGREE DEADBAND XS LOBBY
S LOBBY
OFFICES
(EX) 1-AHU-1 RECONNECT TO (EX) HYDRONIC RUNOUTS------ --
AIR CURTAIN SCHEDULE
MARK LOCATION NOZZLE WIDTH
MAX FPM AT
NOZZLE
FLA ELEC REF
1-A-1 ER VEST. 60" 3750 2217 480/3 32.0 115.0 1,2,3 --
1. CEILING RECESSED
2. NO HEATING OR COOLING
3. MOTOR CONTROL PANEL WITH DOOR LIMIT SWITCH
REMARKS
CFM AT
NOZZLE
HEATER kW MOTOR HP VOLTAGE WEIGHT REMARKS
(2) 1/2
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Columbia, Missouri
M-601
MECHANICAL SCHEDULES
File details come from the government source that posted it.