36C25518R0539-0001003.pdf

PDF 13 MB Posted

Attached to
589-334, CO EXPAND PHARMACY AND LOBBY
Solicitation number
36C25518R0539
Issued by

About this file

36C25518R0539 0001 Drawings Expand Pharmacy-Vol 3.pdf

View the file

Other files

File Type Posted
36C25518C0223-000.docx DOCX document
36C25518R0539-0005000.docx DOCX document
36C25518R0539-0004001.pdf PDF
36C25518R0539-0004000.docx DOCX document
36C25518R0539-0003001.pdf PDF
36C25518R0539-0003000.docx DOCX document
36C25518R0539-0002002.pdf PDF
36C25518R0539-0002000.docx DOCX document
36C25518R0539-0002001.docx DOCX document
36C25518R0539-0001011.pdf PDF
36C25518R0539-0001008.pdf PDF
36C25518R0539-0001009.pdf PDF
36C25518R0539-0001001.pdf PDF
36C25518R0539-0001005.pdf PDF
36C25518R0539-0001004.pdf PDF
36C25518R0539-0001014.pdf PDF
36C25518R0539-0001013.pdf PDF
36C25518R0539-0001002.pdf PDF
36C25518R0539-0001010.pdf PDF
36C25518R0539-0001015.pdf PDF
36C25518R0539-0001012.pdf PDF
36C25518R0539-0001007.pdf PDF
36C25518R0539-0001006.pdf PDF
36C25518R0539-0001016.pdf PDF
36C25518R0539-0001000.docx DOCX document
36C25518R0539-008.pdf PDF
36C25518R0539-005.pdf PDF
36C25518R0539-001.docx DOCX document
36C25518R0539-003.pdf PDF
36C25518R0539-007.pdf PDF
36C25518R0539-006.pdf PDF
36C25518R0539-004.pdf PDF
36C25518R0539-002.pdf PDF
36C25518R0539-000.docx DOCX document
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOT IN SCOPE OF

WORK

NOT IN SCOPE OF WORK

3 3 3 3

3' - 4"

AD1022

26 2728

FEC

DO NOT REMOVE

FLOORING

BEYOND THIS

POINT

18 26

DO NOT REMOVE

FLOORING BEYOND

THIS POINT

GENERAL DEMOLITION NOTES

A. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK

BEGINNING.THE CONTRACTOR IS RESPONSIBLE FOR INFORMING THE ARCHITECT OF

ANY CONDITIONS THAT DIFFER FROM INFORMATION INDICATED IN THE DRAWINGS.

B. PROTECT ALL EXISTING BUILDING COMPONENTS TO REMAIN. REPAIR ANY DAMAGE

AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.

C. VERIFY EXTENT OF DEMOLITION WORK w/ INFO SHOW IN THE DRAWINGS AND WORK

THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE THE INTENDED WORK.

D. ALL WORK SHALL COMPLY w/ REQUIRED LOCAL CODES. CONTRACTOR IS

RESPONSIBLE FOR OBTAINING REQUIRED PERMITS & INSPECTIONS FOR ALL WORK

ASSOCIATED w/ HIS CONTRACT.

E. CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH THE

ORIGINAL STATE OF ADJACENT FINISHES.

F. TYPES OF FLOOR, WALL & CEILING FINISHES INDICATED FOR REMOVAL BY

DEMOLITION NOTES IS FOR CONTRACTOR'S INFORMATION AND HAS BEEN OBTAINED

FROM EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY

MATERIAL TYPES ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN HIS BID.

G. ALL APPLIANCES, FURNITURE AND EQUIPMENT TO REMAIN THE PROPERTY OF THE

OWNER. CONTRACTOR TO COORDINATE REMOVAL, RELOCATION AND STORAGE OF

EQUIPMENT FROM DEMO AREAS WITH OWNER.

H. MISCELLANEOUS FLOOR PENETRATIONS & DEMO FOR NEW MECHANICAL &

ELECTRICAL WORK SHALL BE COORDINATED FROM ARCHITECTURAL, MECHANICAL &

ELECTRICAL PLANS.

I. REFER TO MECHANICAL, PLUMBING & ELECTRICAL DEMO PLANS FOR DEMOLITION,

SALVAGE AND REUSE OF EXISTING ITEMS.

J. PATCH FLOOR AT REMOVED WALLS & CASEWORK. PREPARE FLOOR TO RECEIVE

NEW FLOORING AS REQUIRED.

K. ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES TO RECEIVE INFILL

PER STRUCTURAL DETAILS.

L. REMOVE ALL STAINLESS STEEL CORNER GUARDS CAREFULLY AND GIVE TO THE

OWNER.

M. ALL SIGNAGE TO BE RETURNED TO THE VA IF NOT RELOCATED OR REUSED

N. SAVE ANY EXISTING DOME MIRRORS FOR USE IN REMODELED SPACE OR RETURN TO

VA

DEMOLITION PLAN INDICATES ASSUMED

ASBESTOS CONTAINING MATERIAL (ACM)

WHERE OBSERVED. REFER TO ASBESTOS

ABATEMENT SPECIFICATION SECTION FOR

FURTHER INFORMATION REGARDING REMOVAL

OF ACM AND SPECIFIC TYPES AND LOCATIONS.

ABATEMENT ACTIVITIES WILL REQUIRE TO BE

PHASED ACCORDING TO THE PHASING PLAN

FOR THE PROJECT.

ASBESTOS DEMOLITION NOTES

DEMOLITION LEGEND

DOOR & FRAME TO BE REMOVED

WALL TO BE REMOVED

WALL TO REMAIN

DOOR & FRAME TO REMAIN

AREA FOR SELECTIVE WOOD

PANEL, BASE RAIL, OR WALL

GUARD REMOVAL

R.O.I.R.O.I.

TRANSCRIPTION

OFF.

E144

OFFICE

F159

OFFICE

F160

OFFICE

F161

OFFICE

F162

OFFICE

F164

OFFICE

F165

HOME

TELEHEALTH

N.

ENVIRO.

MGT.

OFFICE

OFFICE

BLDG.

MGT.

LKR./

LNGE./

TLT. TLT.

OFFICE

EXAM

ST. LNGE.

TLT.

TLT.

CORR.

CORR.

CORR.

BLDG.

MGT.

LKR./

LNGE./

TLT.

PHARMACY

CASHIER

E142

TELEHEALTH

IMAGING

E143

TRAVEL

E140

STAIR #11

F173

F.M.S.

ENG.

F170

SIGNAL

F172

CORR.

C1F22

CASHIER

WINDOWS

C1E2

ENTR.

VEST.

TUBE

STATION

TUBE

STATION ELEV #12

PHARMACYCORR.

ADDITION

REMODEL

AREAS

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

EXPAND PHARMACY AND LOBBY

AD101

FIRST FLOOR PLAN - DEMOLITION

589-334

04/03/2018

1/8" = 1'-0" A

FIRST FLOOR PLAN - DEMOLITION

DEMO SCHEDULE

# DESCRIPTION

1 REMOVE EXISTING WALL OR PORTION OF WALL AS INDICATED - PATCH ADJ. EXIST. WALL AS REQ.

2 REMOVE EXISTING DOOR & FRAME

3 REMOVE EXISTING WINDOW

4 REMOVE EXISTING PLUMBING FIXTURE & ANY ASSOCIATED PLUMBING (REF. PLUMBING). REPAIR FLOOR/ WALL/ CEILING AS REQUIRED

5 REMOVE CASEWORK

6 REMOVE CORNER GUARD OR END GUARD; REPAIR WALL AS REQUIRED

7 REMOVE EXISTING EXTERIOR WALL OR PORTION OF WALL AS INDICATED, INCLUDING VENEER AND BACKUP

8 REMOVE EXISTING FLOORING, BASE & GLUE RESIDUE USING MECHANICAL MEANS. PREP SUB-FLOORING FOR NEW FLOOR COVERING

9 REMOVE EXISTING FIRE EXTINGUISHER CABINET

10 REMOVE EXISTING WOOD PANEL, METAL FILLER, AND METAL BASE AS REQUIRED; PATCH WALL AS REQUIRED

11 REMOVE EXISTING PASS-THROUGH DRAWER - PATCH WALL ON BOTH SIDES TO MATCH EXISTING - BASE BID ONLY

12 REF. CIVIL DRAWINGS FOR SCOPE OF SITE DEMOLITION; REVIEW ONSITE WITH COR WHICH DEMO ITEMS SHALL BE RETURNED TO OWNER

13 REMOVE ALL EXISTING METAL BASE & SAVE FOR REUSE IN REMODELED SPACE; RETURN ANY EXTRA MATERIAL TO THE VA

14 REMOVE PORTION OF WALL FOR NEW DOOR OPENING

15 REMOVE EXISTING STONE VENEER COVERING STRUCTURAL BEAM - REF. STRUCTURAL

16 REMOVE EXISTING DUMBWAITER AND ALL ASSOCIATED HARDWARE

17 REMOVE LIFT SYSTEM; RETURN TO VA

18 REMOVE WALL-ATTACHED MODULAR FURNITURE; RETURN TO VA. PATCH WALLS, PREPARE TO RECEIVE NEW FINISH

19 REMOVE WALL GUARDS AND CORNER GUARDS; REPAIR WALL AS REQ'D

20 REMOVE CHAIR RAILS; REPAIR WALL AS REQ'D

21 REMOVE CUBICLE CURTAIN AND TRACKS

22 REMOVE EXISTING BASE RAIL; REPAIR WALL AS REQ'D

23 REMOVE EXISTING OUTLET & HOSE BIB, REF. CIVIL & ELEC

24 REMOVE LIGHT FIXTURE, REF. ELEC.

25 REMOVE EXISTING KNOX BOX AND SAVE FOR USE IN REMODELED SPACE

26 REMOVE EXISTING SECURITY CAMERA AND RETURN TO OWNER, REF. ELEC.

27 REMOVE MECHANICAL UNIT, LIGHT FIXTURE & EXIT SIGNAGE, REF. ELEC & MECH.

28 REMOVE EXISTING FIRE ALARM & HUMIDITY CONTROL & RELOCATE; REF. MECH.

29 PRESERVE PNEUMATIC TUBE STATION. - RETURN TO VA

30 REMOVE EXISTING BLOCK WALL OR PORTION OF WALL AS INDICATED - PATCH ADJ. EXIST. WALL AS REQ.

31 REMOVE PHARMACY WINDOW & PHARMACY PASS-THROUGH DRAWER IN BASE BID ONLY

32 VA TO REMOVE/RELOCATE SAFE PRIOR TO CONSTRUCTION

33 RELOCATE T-STAT AS REQ'D FOR NEW CONSTRUCTION; REF. MECHANICAL

34 REMOVE EXISTING MED GAS ZONE BOX, OUTLET, OR ALARM PANEL & ANY ASSOCIATED PIPING - REF. MECH; PATCH & REPAIR

WALLS/CEILING AS REQ'D

35 REMOVE EXISTING BRICK VENEER WHERE INDICATED -REF ELEVATIONS FOR ADDITIONAL INFO

4' 8' 16'

1/8" = 1'-0"

0'

N 1" = 80'-0"

KEY PLAN FIRST FLOOR

N

3 3 3 3 3

NOT IN SCOPE OF

WORK

OPEN TO

BELOW

181818

AD1022

5' - 11"

F

IE

L D

V E

R

IF

Y E

X

IS

T

IN

G F

L O

O R

IN

G

8 8

KEEP

FLOORIN

G

3' - 10"

3' - 10"6' - 7"

EXTENT OF

FLOORING

DEMOLITION

3' - 10"

DEMOLITION LEGEND

DOOR & FRAME TO BE REMOVED

WALL TO BE REMOVED

WALL TO REMAIN

DOOR & FRAME TO REMAIN

AREA FOR SELECTIVE WOOD

PANEL, BASE RAIL, OR WALL

GUARD REMOVAL

GENERAL DEMOLITION NOTES

A. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK

BEGINNING.THE CONTRACTOR IS RESPONSIBLE FOR INFORMING THE ARCHITECT OF

ANY CONDITIONS THAT DIFFER FROM INFORMATION INDICATED IN THE DRAWINGS.

B. PROTECT ALL EXISTING BUILDING COMPONENTS TO REMAIN. REPAIR ANY DAMAGE

AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.

C. VERIFY EXTENT OF DEMOLITION WORK w/ INFO SHOW IN THE DRAWINGS AND WORK

THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE THE INTENDED WORK.

D. ALL WORK SHALL COMPLY w/ REQUIRED LOCAL CODES. CONTRACTOR IS

RESPONSIBLE FOR OBTAINING REQUIRED PERMITS & INSPECTIONS FOR ALL WORK

ASSOCIATED w/ HIS CONTRACT.

E. CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH THE

ORIGINAL STATE OF ADJACENT FINISHES.

F. TYPES OF FLOOR, WALL & CEILING FINISHES INDICATED FOR REMOVAL BY

DEMOLITION NOTES IS FOR CONTRACTOR'S INFORMATION AND HAS BEEN OBTAINED

FROM EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY

MATERIAL TYPES ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN HIS BID.

G. ALL APPLIANCES, FURNITURE AND EQUIPMENT TO REMAIN THE PROPERTY OF THE

OWNER. CONTRACTOR TO COORDINATE REMOVAL, RELOCATION AND STORAGE OF

EQUIPMENT FROM DEMO AREAS WITH OWNER.

H. MISCELLANEOUS FLOOR PENETRATIONS & DEMO FOR NEW MECHANICAL &

ELECTRICAL WORK SHALL BE COORDINATED FROM ARCHITECTURAL, MECHANICAL &

ELECTRICAL PLANS.

I. REFER TO MECHANICAL, PLUMBING & ELECTRICAL DEMO PLANS FOR DEMOLITION,

SALVAGE AND REUSE OF EXISTING ITEMS.

J. PATCH FLOOR AT REMOVED WALLS & CASEWORK. PREPARE FLOOR TO RECEIVE

NEW FLOORING AS REQUIRED.

K. ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES TO RECEIVE INFILL

PER STRUCTURAL DETAILS.

L. REMOVE ALL STAINLESS STEEL CORNER GUARDS CAREFULLY AND GIVE TO THE

OWNER.

M. ALL SIGNAGE TO BE RETURNED TO THE VA IF NOT RELOCATED OR REUSED

N. SAVE ANY EXISTING DOME MIRRORS FOR USE IN REMODELED SPACE OR RETURN TO

VA

DEMOLITION PLAN INDICATES ASSUMED

ASBESTOS CONTAINING MATERIAL (ACM)

WHERE OBSERVED. REFER TO ASBESTOS

ABATEMENT SPECIFICATION SECTION FOR

FURTHER INFORMATION REGARDING REMOVAL

OF ACM AND SPECIFIC TYPES AND LOCATIONS.

ABATEMENT ACTIVITIES WILL REQUIRE TO BE

PHASED ACCORDING TO THE PHASING PLAN

FOR THE PROJECT.

ASBESTOS DEMOLITION NOTES

STAIR #4

A250

FIRE CL.

A250A

HOOD

ROOM

CHEMO.

OFFICE

EXAM

EXAM

F240

TLT.

SOILED

UTIL.

EXAM

ALCOVE

C2F17

CORR.

EXAM

EXAM 10

F241

EXAM 11

F243

EXAM 12

F244

EXAM 16

PHYS.

OFFICE

PROCEDURE

& EXAM 1

MICROSCOPE

ROOM

ST. TLT.

EXAM 15

OFFICE

EXAM 17

EXAM 14

F248

EXAM 13

F247

EXAM 5

TLT.

E207

TLT.

E208

ELECTRICAL

E202

TELE/

DATA

E203

OFFICE

E204

OFFICE

E204A

CORR.

C2F20

FAM.

COUNSELING

E209

JAN.

E210A

SOILED

UTIL.

E210

EXAM

E211

STG.

F253

EXAM

E212

WK. RM.

E215A

CLEAN

UTIL.

E214

N. STN.

E213

CORR.

C2F18

CORR.

RECEPT.

N. STN.

DWTR.

RM.

E206

TLT.

E205

EXAM

E226

ATTENDING

OFFICE./

EXAM

E225

EXAM

E223

EXAM

E222

PROCS.

RM.

E220

CORR.

C2E3

CORR.

C2E2

CHECK

IN/OUT

E224A

WAITING

AREA

E224

CORR.

C2E4

CORR.

C2E1

ELECT.

CLOSET

F252

EXAM

E219

EXAM

E218

EXAM

E217

EXAM RM.

E216

INTERN/

RES.

SWAMP

E215

STAIR #11

F248

EXAM/

OFFICE

E221

CORR.

C2E6

CORR.

CORR.

CORR.

C2E7

OFFICE

F255

CLEAN

DISPATCH

EXAM 18

736 -0 FIN. FLOOR

0' - 0"

749-9 1/4 SECOND

FLOOR

13' - 9 1/4"

762-5 1/4 THIRD

FLOOR

26' - 5 1/4"

ACA

ACA

10.6

ACA

ACA

11.5

ACA

REMOVE EXISTING

STOREFRONT

WINDOW

REMOVE EXISTING

STONE PARAPET &

PARAPET STONE

CAP

REMOVE EXISTING

DOOR &

STOREFRONT

WINDOWS

REMOVE EXISTING BRICK

WHERE INDICATED - REF.

STRUCT.

736 -0 FIN. FLOOR

0' - 0"

749-9 1/4 SECOND

FLOOR

13' - 9 1/4"

762-5 1/4 THIRD

FLOOR

26' - 5 1/4"

ACA

H

ACA

G

ACA

E

ACA

D

ACA

E.1

ACA

F

ACA

D.8

ACA

D.7

F.2 F.9 G.5E.5 F.1

REMOVE EXISTING

STOREFRONT

WINDOW

REMOVE

EXISTING

BRICK - REF.

STRUCT.

REMOVE BRICK

& MTL STUDS -

REF. STRUCT.

ADDITION

REMODEL

AREA

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

EXPAND PHARMACY AND LOBBY

AD102

SECOND FLOOR PLAN - DEMOLITION

589-334

04/03/2018

1/8" = 1'-0" A

SECOND FLOOR PLAN - DEMO

DEMO SCHEDULE

# DESCRIPTION

1 REMOVE EXISTING WALL OR PORTION OF WALL AS INDICATED - PATCH ADJ. EXIST. WALL AS REQ.

2 REMOVE EXISTING DOOR & FRAME

3 REMOVE EXISTING WINDOW

4 REMOVE EXISTING PLUMBING FIXTURE & ANY ASSOCIATED PLUMBING (REF. PLUMBING). REPAIR FLOOR/ WALL/ CEILING AS REQUIRED

5 REMOVE CASEWORK

6 REMOVE CORNER GUARD OR END GUARD; REPAIR WALL AS REQUIRED

7 REMOVE EXISTING EXTERIOR WALL OR PORTION OF WALL AS INDICATED, INCLUDING VENEER AND BACKUP

8 REMOVE EXISTING FLOORING, BASE & GLUE RESIDUE USING MECHANICAL MEANS. PREP SUB-FLOORING FOR NEW FLOOR COVERING

9 REMOVE EXISTING FIRE EXTINGUISHER CABINET

10 REMOVE EXISTING WOOD PANEL, METAL FILLER, AND METAL BASE AS REQUIRED; PATCH WALL AS REQUIRED

11 REMOVE EXISTING PASS-THROUGH DRAWER - PATCH WALL ON BOTH SIDES TO MATCH EXISTING - BASE BID ONLY

12 REF. CIVIL DRAWINGS FOR SCOPE OF SITE DEMOLITION; REVIEW ONSITE WITH COR WHICH DEMO ITEMS SHALL BE RETURNED TO OWNER

13 REMOVE ALL EXISTING METAL BASE & SAVE FOR REUSE IN REMODELED SPACE; RETURN ANY EXTRA MATERIAL TO THE VA

14 REMOVE PORTION OF WALL FOR NEW DOOR OPENING

15 REMOVE EXISTING STONE VENEER COVERING STRUCTURAL BEAM - REF. STRUCTURAL

16 REMOVE EXISTING DUMBWAITER AND ALL ASSOCIATED HARDWARE

17 REMOVE LIFT SYSTEM; RETURN TO VA

18 REMOVE WALL-ATTACHED MODULAR FURNITURE; RETURN TO VA. PATCH WALLS, PREPARE TO RECEIVE NEW FINISH

19 REMOVE WALL GUARDS AND CORNER GUARDS; REPAIR WALL AS REQ'D

20 REMOVE CHAIR RAILS; REPAIR WALL AS REQ'D

21 REMOVE CUBICLE CURTAIN AND TRACKS

22 REMOVE EXISTING BASE RAIL; REPAIR WALL AS REQ'D

23 REMOVE EXISTING OUTLET & HOSE BIB, REF. CIVIL & ELEC

24 REMOVE LIGHT FIXTURE, REF. ELEC.

25 REMOVE EXISTING KNOX BOX AND SAVE FOR USE IN REMODELED SPACE

26 REMOVE EXISTING SECURITY CAMERA AND RETURN TO OWNER, REF. ELEC.

27 REMOVE MECHANICAL UNIT, LIGHT FIXTURE & EXIT SIGNAGE, REF. ELEC & MECH.

28 REMOVE EXISTING FIRE ALARM & HUMIDITY CONTROL & RELOCATE; REF. MECH.

29 PRESERVE PNEUMATIC TUBE STATION. - RETURN TO VA

30 REMOVE EXISTING BLOCK WALL OR PORTION OF WALL AS INDICATED - PATCH ADJ. EXIST. WALL AS REQ.

31 REMOVE PHARMACY WINDOW & PHARMACY PASS-THROUGH DRAWER IN BASE BID ONLY

32 VA TO REMOVE/RELOCATE SAFE PRIOR TO CONSTRUCTION

33 RELOCATE T-STAT AS REQ'D FOR NEW CONSTRUCTION; REF. MECHANICAL

34 REMOVE EXISTING MED GAS ZONE BOX, OUTLET, OR ALARM PANEL & ANY ASSOCIATED PIPING - REF. MECH; PATCH & REPAIR

WALLS/CEILING AS REQ'D

35 REMOVE EXISTING BRICK VENEER WHERE INDICATED -REF ELEVATIONS FOR ADDITIONAL INFO

N

4' 8' 16'

1/8" = 1'-0"

0'

3/32" = 1'-0"

NORTH DEMO ELEVATION

3/32" = 1'-0"

WEST DEMO ELEVATION

1" = 80'-0"

KEY PLAN SECOND FLOOR

1 2

1 2

1 2

1 2

1 2

NOT IN SCOPE OF

WORK

NOT IN SCOPE OF

WORK

E146E145

E144

C1F14

F159F160F161F162F164F165F166 F169

F142

F155

F156

F157

F158

F142*

F154

F153F152

F145 F144F146

F149

F148

F147

F168 F171A

F163A

F171

F150

F151

F151A

F151B

C1F17*

C1F19

C1F18

C1F17

C1F20

F1F21

F167

E141

E142

E143

E140

C1E9

E138 E139

E147A

F173

F170F172

C1F22

E137

E107

E106

C1E7

C1E2

E1100

E102C

E102D

E102E

A119A

A121

A123

E102A

E102B

E102

E102GE102F

C1E5

C1E6

C1E3

E101

E102IE102H

A125

A129B

A129B

A130

A131

E105

E104

E103

C1A1

C1E8

C1A3

A119

E102J

F150A

E141A E141B

F163

E147B

ADDITION

REMODEL

AREAS

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

EXPAND PHARMACY AND LOBBY

AD103

FIRST FLOOR - REFLECTED CEILING PLAN

- DEMOLITION

589-334

04/03/2018

1/8" = 1'-0" A

FIRST FLOOR - REFLECTED CEILING

PLAN - DEMOLITIONN

4' 8' 16'

1/8" = 1'-0"

0'

DEMO PLAN NOTES - RCP

# DESCRIPTION

1 REMOVE EXISTING CEILING

2 REMOVE EXISTING MECHANICAL AND ELECTRICAL FIXTURES, REF. MECH. & ELEC DRAWINGS

3 REMOVE EXISTING EXTERIOR LIGHT FIXTURE, REF. ELEC

4 REMOVE EXISTING PATIENT LIFT SYSTEM & RETURN TO OWNER; REF. ELEC.

5 RELOCATE EXISTING SECURITY CAMERA AS REQUIRED FOR ADDITION; REF. ELEC.

6 EXISTING CEILING TO REMAIN, SPLICE GRID AT NEW CONSTRUCTION

7 EXISTING CONCRETE STUCCO SOFFIT TO REMAIN

8 EXISTING DOME MIRROR TO REMAIN

1" = 80'-0"

KEY PLAN FIRST FLOOR

E206

1 1

2 2

NOT IN SCOPE OF

WORK

NOT IN SCOPE OF

WORK

NOT IN SCOPE OF

WORK

A250

A250A

F236

F237A

F239

F240

F238

F233

F237

C2F17

C2F16

F242

F241F243F244

F245

F230

F231 F232

F250

F246

F251

F249

F248 F247

F234

E207 E208

E202

E203

E204E204A

C2F20

E209

E210A

E210

E211

F253

E212

E215A

E214

E213

C2F18

C2F19

F228

F229

E206

E205

E226

E225

E223

E222 E220

C2E3

C2E2

E224A

E224

C2E4

C2E1

F252

E219 E218 E217 E216

E215

F248

E221

C2E6

C2F14

C2F15

C2E7

F255

F257

F256

ADDITION

REMODEL

AREA

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

EXPAND PHARMACY AND LOBBY

AD104

SECOND FLOOR - REFLECTED CEILING

PLAN - DEMOLITION

589-334

04/03/2018

1/8" = 1'-0" A

SECOND FLOOR - REFLECTED CEILING

PLAN - DEMOLITION

4' 8' 16'

1/8" = 1'-0"

0'

N

DEMO PLAN NOTES - RCP

# DESCRIPTION

1 REMOVE EXISTING CEILING

2 REMOVE EXISTING MECHANICAL AND ELECTRICAL FIXTURES, REF. MECH. & ELEC DRAWINGS

3 REMOVE EXISTING EXTERIOR LIGHT FIXTURE, REF. ELEC

4 REMOVE EXISTING PATIENT LIFT SYSTEM & RETURN TO OWNER; REF. ELEC.

5 RELOCATE EXISTING SECURITY CAMERA AS REQUIRED FOR ADDITION; REF. ELEC.

6 EXISTING CEILING TO REMAIN, SPLICE GRID AT NEW CONSTRUCTION

7 EXISTING CONCRETE STUCCO SOFFIT TO REMAIN

8 EXISTING DOME MIRROR TO REMAIN

1" = 80'-0"

KEY PLAN SECOND FLOOR

DN

ADDITION

REMODEL

AREAS

NOT IN SCOPE OF

WORK

NOT IN SCOPE OF WORK

AS301

AGENT

CASHIER

E142

TRAVEL

E140

WAITING

F174

CONSULT

F174A

CONSULT

F174B

CONSULT

F174C

STORAGE

F179

SWAMP

F176

CORRIDOR

F1F23

CORRIDOR

F1F22

STAIR #11

F173

F.M.S.

ENG.

F170

SAFE

CAROUSEL

SCRIPT PRO

PINPOINT

TRAVEL

E144

VAULT

F178

OFFICE

F175

AS401

AS401

AS401

A3

AI402

AI402

AI402 6

AI402

A2

BID DEDUCT #2

F174CF174BF174A

F176

F175

F177 F179

A1A1

F1F23

E144

OFFICE

F164

OFFICE

F162

OFFICE

F161

OFFICE

F160

OFFICE

F159

MED

ADMIN

E141

LOBBY

C1E3

AS502

CORR

F1F21

AI402

CAROUSEL

F178A

F178B

PHARMACY

WORK

F177

DISPENSING

F177A

MAIL

F177B

AS105

AS101

AS101

E142

AS601

AS105

AS105

AS105

AS105

F1F22

A2

AS105

AS105

AS105

AS105

AS101

AS105

AS105

SE140

SE142

SF177A

AI402

AI402

FEC

A3

1AS101

ELEC

F180

F180

F173

PROTECTIVE WIRE MESH

AI4025

AS502

AS601

AS601

PROTECTIV

E WIRE

MESH

AS3011

ACA

F.9

DOOR AS

SCHEDULED

NEW TUBE STATION TO

BE PURCHASED AND

INSTALLED BY

CONTRACTOR; EXISTING

TUBE STATION TO BE

RETURNED TO VA

5/8" TYPE X GYP

ON 3 5/8" MTL

STUDS

5/8" TYPE X GYP

BD. ON 3 5/8" MTL.

STUDS @ 16" O.C.

5/8" TYPE X GYP BD ON 7/8" MTL.

HAT CHANNEL @ 16" O.C. ON

CMU - REF. SPEC.

CAULK - TYP.

2HR COLUMN WRAP - UL DESIGN X528 - REF. SPECS.

WIRE MESH REINFORCING

8' CMU WALL - REF.

STRUCT.

5/8" GYP BD. ON 7/8"

HAT CHANNEL @ 16"

O.C.

5/8" TYPE "X" GYP

BD. ON 3 5/8" MTL.

STUDS @ 16" O.C.

5/8" TYPE "X" GYP BD.

ON 1 5/8" MTL. STUDS

BATT. INSUL.

MAIL

F177B

VAULT

F178

WIRE MESH REINFORCING

10.1

G.5

5/8" GYP BD. ON 7/8" MTL.

HAT CHANNEL ON CMU -

REF. SPEC.

5/8" TYPE X GYP

BD. ON 3 5/8" MTL

STUDS @ 16" 0.C.

5/8" TYPE X GYP BD.

ON 3 5/8" MTL.

STUDS @ 16" O.C.

5/8" TYPE XGYP BD.

ON 2 1/2" MTL.

STUDS

5/8" TYPE X GYP BD.

ON 7/8" MTL. HAT

CHANNEL

CAULK - TYP.

2HR COLUMN

WRAP - UL

DESIGN X528 -

REF. SPECS.

COLUMN, REF.

STRUCTURAL

WIRE MESH REINFORCING

WIRE MESH REINFORCING

6' - 6"

GYP CONTROL JOINT

@ SEAM OF

REMOVABLE WALL

PANEL - EXTEND TO

TOP OF WALL

GYP CONTROL JOINT

@ SEAM OF

REMOVABLE WALL

PANEL - EXTEND TO

TOP OF WALL

5/8" TYPE X GYP. BD. ON 3

5/8" MTL STUDS @ 16"

O.C.

MEDCAROUSEL; REF.

EQUIPMENT PLAN

WIRE MESH

REINFORCING

ACA

ACA

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

EXPAND PHARMACY AND LOBBY

AS101

FIRST FLOOR - FLOOR PLAN

589-334

04/03/2018

N

4' 8' 16'

1/8" = 1'-0"

0'

1" = 80'-0"

KEY PLAN FIRST FLOOR

PLAN NOTES - FLOOR PLAN

# DESCRIPTION

1 REMOVEABLE PORTION OF WALL FOR INSTALLATION OF MEDCAROUSEL

2 RELOCATED KNOX BOX

3 PROVIDE A RAMP AND HANDRAIL, REF. CIVIL

4 ALIGN WALLS

5 ALIGN FACE OF GYP WITH EXIST ADJ. FACE OF GYP

6 PATCH FLOOR AS REQ'D WHERE METAL BASE WAS REMOVED

1/8" = 1'-0" A

FIRST FLOOR PLAN

1 1/2" = 1'-0"

PNEUMATIC TUBE STATION PLAN

DETAIL

1 1/2" = 1'-0"

PLAN DETAIL - VAULT CONNECTION

1 1/2" = 1'-0"

COLUMN WRAP DETAIL

1 1/2" = 1'-0"

REMOVEABLE WALL PANEL DETAIL

DN

ADDITION

REMODEL

AREAS

AS301

AI402

CORRIDOR

F1F23

STORAGE

F177

ACA

ACA

ACA

ACA

10.6

ACA

ACA

11.5

ACA

ACA

H

ACA

G

ACA

E

ACA

D

ACA

C

ACA

E.1

ACA

F

ACA

B.2

ACA

D.8

ACA

D.7

BD177A BD177B

F1F23

A3

A2

AS502

ACA

10.1

11.8

F.2 F.9 G.5

12.1

E.5 F.1

BID DEDUCT #2

AS105

AS105

AS105

AS105

AS105

AS105

AS105

AS105

STAIR #11

F173

OFFICE

F159

OFFICE

F160

OFFICE

F161

OFFICE

F162

OFFICE

F164

ELEC

F180

F180

F173

NOT IN SCOPE OF

WORK

NOT IN SCOPE OF WORK

TRAVEL

E140

SAFE

PINPOINT

TRAVEL

E144

A1A1

FEC

E144

E142

F1F22

CORRIDOR

F1F22

AGENT

CASHIER

E142

F.M.S.

ENG.

F170

AS601

CORR

F1F21

AS105

SE140 SE142

AS502

AS601

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

EXPAND PHARMACY AND LOBBY

AS101.2

FIRST FLOOR - FLOOR PLAN - BID DEDUCT

#2

589-334

04/03/2018

1" = 80'-0"

KEY PLAN FIRST FLOOR

1/8" = 1'-0" A

FIRST FLOOR PLAN - BID DEDUCT #2

N

4' 8' 16'

1/8" = 1'-0"

0'

PLAN NOTES - FLOOR PLAN

# DESCRIPTION

1 REMOVEABLE PORTION OF WALL FOR INSTALLATION OF MEDCAROUSEL

2 RELOCATED KNOX BOX

3 PROVIDE A RAMP AND HANDRAIL, REF. CIVIL

4 ALIGN WALLS

5 ALIGN FACE OF GYP WITH EXIST ADJ. FACE OF GYP

6 PATCH FLOOR AS REQ'D WHERE METAL BASE WAS REMOVED

AS301

WAITING /

DILATION

E209

DIRTY

E253

ELEC

F252

SWAMP

E215

LASER

E255

TLT

F253

EXAM 1

E226

EXAM 2

E225

EXAM 3

E223

EXAM 4

E222

EXAM 5

E221

EXAM 6

E219

EXAM 7

E218

EXAM 8

E217 FUNDUS

E216

VISUAL

FIELDS

E211

VISUAL

FIELDS

E212

REFRAC

E212A

PROCEDURE

E213

EXAM 9

E220

JAN

E205

EQUIP

E205A

N.S.

E211AWORK RM.

E224A

REFRAC

E210

IMAGING

F256

EXAM 10

F273

EXAM 22

F258

EXAM 21

F259

EXAM 11

F272

EXAM 12

F271

EXAM 13

F270

EXAM 14

F269

EXAM 18

F262

EXAM 19

F261

EXAM 20

F260

EXAM 15

F267

EXAM 16

F266

EXAM 17

F265

WAITING

DILATION

F257

WAITING

E206

NOT IN SCOPE OF

WORK

OPEN TO

BELOW

CORR

C2E3

CORR

C2E2

CORR

C2E1

CORR

C2F21

STAIR #11

F248

CORR

C2F22

CORR

C2F24

PRE-

CATARACT

E214 CLEAN

E254

ADMIN

OFFICE

F255

NURSE

F264

WAITING

F268

WAITING

F263

AS102

B

AS401

AS401

AS401

C2F20

E216

E224

E205

E215

F256

C2F22 F267

F266

F265

F259 F260 F261 F262

F269F270F271F272F273

E220

F248

E211

E212

E253

E254

A4 A5

A6

A7

AI401

AI401

AI4018

A5

BID DEDUCT #1

E213 E255

F258

AS502

ADMIT

E224

HALL

C2E4

EXAM

F247

EXAM

F244

EXAM

F243

EXAM

F241

EXAM

F240

CORR

C2F20

CORR

C2F23

AI401 10

AI401 56

AI401

C2F21

INFILL FLOOR SLAB

- REF. STRUCTURAL

AI401 7

AI4019

AS102

E209

AS504

Sim

AS102

AS105

AS105

15AS105

AS105

AS105

AS105

AS105

AS105

AS105

AS105

AI401

AI401 10 AI401 10 AI401 10 AI401 10

AI40110

AI40110

AI40110AI40110

AI40110

11 11 11 11

11 11 11

AI401 20

AS3011

C2E2

AI501

AI401

19 20

AI401

19 20

AI40112

AI40112

AI40112

AI401 12

AI401

AI401 12

AI401

AI401

AI401

SIM

SIM

SIM

SIM

SIM

REV

SIM SIM

FEC

AS105

11"

AS502

AI40122

AI40122

ADDITION

REMODEL

AREA

TLT

F253

AI40115

F253

AI401 21

DIRTY

E253

E253

SPANDREL GLASS - REF. SPECS.

ANODIZED ALUM. STOREFRONT

SYSTEM W/ 1" INSUL GLAZING -

REF SPEC

5/8" GYP BD. ON 2 1/2"

MTL. STUDS @ 16"

O.C.

5/8" GYP BD. ON

3 5/8" MTL.

STUDS @ 16"

O.C.

SS SILL - REF. FINISH SCHED.

WOOD BLOCKING

SS SILL - REF. FINISH

SCHED.

A7

BATT. INSUL.

5/8" GYP BD. ON 2 1/2"

MTL. STUDS @ 16"

O.C.

CAULK TO STOREFRONT

CAULK TO STOREFRONT

BREAK MTL. WALL CAP -

FINISH TO MATCH

STOREFRONT

ANODIZED ALUM

STOREFRONT SYSTEM W/

1" INSUL GLAZING -REF.

SPECS

5/8" TYPE "X" GYP. BD.

ON 3 5/8" MTL. STUDS

@ 16" 0.C.

EXAM 17

F265

EXAM 16

F266

SS SILL - REF. FINISH

SCHEDULE

SS SILL - REF. FINISH

SCHEDULE

ACA

H

ACA

H

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

EXPAND PHARMACY AND LOBBY

AS102

SECOND FLOOR - FLOOR PLAN

589-334

04/03/2018

1/8" = 1'-0" A

SECOND FLOOR PLAN

1" = 80'-0"

KEY PLAN SECOND FLOOR

1/4" = 1'-0" B

ENLARGED PLAN - F253 TLT

N

4' 8' 16'

1/8" = 1'-0"

0'

1 1/2" = 1'-0"

PLAN DETAIL - WINDOW A7

1 1/2" = 1'-0"

PLAN DETAIL - WALL CAP

AS301

AS401

AS401

AS401

AI401

AI401

AI4018

A6

A6

BD265

STORAGE

BD265

E 1

ACA

ACA

ACA

ACA

ACA

10.6

ACA

ACA

11.5

ACA

ACA

H

ACA

G

ACA

E

ACA

D

ACA

C

ACA

B

ACA

E.1

ACA

F

ACA

B.2

ACA

D.8

ACA

D.7

AS502

ACA

10.1

11.8

F.2 F.9 G.5

12.1

AI401 10

AI401 56

AI401

E.5

AI401 7

AI4019

F.1

AS3011

NOT IN SCOPE OF

WORK

NOT IN SCOPE OF WORK

AI401

WAITING /

DILATION

E209

DIRTY

E253

ELEC

F252

SWAMP

E215LASER

E255

TLT

F253

EXAM 1

E226

EXAM 2

E225

EXAM 3

E223

EXAM 4

E222

EXAM 5

E221

EXAM 6

E219

EXAM 7

E218 EXAM 8

E217

FUNDUS

E216

VISUAL

FIELDS

E211

VISUAL

FIELDS

E212

REFRAC

E212A

PROCEDURE

E213

EXAM 9

E220

JAN

E205

EQUIP

E205A

N.S.

E211AWORK RM.

E224A

REFRAC

E210

IMAGING

F256

EXAM 10

F273

EXAM 22

F258

EXAM 21

F259

EXAM 11

F272

EXAM 12

F271

EXAM 13

F270

EXAM 14

F269

EXAM 18

F262

EXAM 19

F261

EXAM 20

F260

WAITING

DILATION

F257

WAITING

E206

CORR

C2E3

CORR

C2E2

CORR

C2E1

CORR

C2F21

STAIR #11

F248

CORR

C2F22

CORR

C2F24

CORR

C2F23

WAITING

F263

NURSE

F264

WAITING

F268

PRE-

CATARACT

E214

CLEAN

E254

ADMIN

OFFICE

F255

ADMIT

E224

HALL

C2E4

EXAM

F247

EXAM

F244

EXAM

F243

EXAM

F241

EXAM

F240

CORR

C2F20

BID DEDUCT #1

AI401 10 AI401 10 AI401 10 AI401 10

AI40110AI40110AI40110AI40110AI40110

11 11 11 11

11 11 11 11

AS105

AS105

AS105

AS105

AS105

AS105

F273 F272 F271 F270 F269

F262F261F260F259F258

AS504

A4A5

E216 F256

E215

E255E213

E220

E205

E211

E212

E254

E253

E209

C2F20

C2F21

F248

INFILL FLOOR SLAB

- REF. STRUCTURAL

AS105

AS105

AS105

AS105

AS102

B

AI40112

AS502

AI40122

AI40122

AI40112

AI40112

AI401 12

AI401

AI401 12

AI401

AI401

AI401

/2

11 1/2"

A5

AI501

E224

C2F22

AS105

ADDITION

REMODEL

AREA

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

EXPAND PHARMACY AND LOBBY

AS102.1

SECOND FLOOR - FLOOR PLAN - BID

DEDUCT #1

589-334

04/03/2018

1/8" = 1'-0" A

SECOND FLOOR PLAN - BID DEDUCT #1

1" = 80'-0"

KEY PLAN SECOND FLOORN

4' 8' 16'

1/8" = 1'-0"

0'

WALL MATERIALS

LEGEND FOR WALL TAGS

MATERIAL

WIDTH

S - STRUCTURAL METAL STUDS, 20 ga. OR

HEAVIER, (REF. STRUCT.)

L - LIGHT GAUGE METAL STUDS, 20 ga. INTERIOR, 16 ga.

EXTERIOR (REF. SPECS.)

B - CONCRETE MASONRY UNIT, STANDARD

WEIGHTS FOR EXTERIOR & INTERIOR, UNLESS

NOTED OTHERWISE (REF. STRUCT.)

WALL WIDTHS

0 - 7/8" HAT CHANNEL

1 - 1 5/8" HAT CHANNEL/ STUDS

4 - 4" METAL STUD FRAMING

6 - 6" METAL STUD FRAMING OR CONCRETE MASONRY UNIT

8 - 8" METAL STUD FRAMING OR CONCRETE MASONRY

UNIT

NOTES:

PROVIDE ACCOUSTICAL SEALANT AT TOP & BOTTOM AND ALL

PENETRATIONS OF WALLS WITH SOUND BATT.

ALL STUD FRAMING TO BE 16" O.C., TYP.

PROVIDE SEALANT AT TOP & BOTTOM AND ALL PENETRATIONS OF

SMOKE PARTITION WALLS AS REQUIRED BY CODE.

PROVIDE ALL NEW WALLS THAT GO TO STRUCTURE w/ 1 1/2"

MTL. DEFLECTION TRACK - REF STRUCT.

N - NONE

A - ACC0USTICAL

XXXX

INSULATION

WALL INSULATION

WALL HEIGHT

SHADED WALLS INDICATES WALLS

THAT EXTEND TO DECK

INSTALL 5/8" TYPE X GYP BD ON ONE SIDE OF FURRING,

TYP. INSTALL 5/8" TYPE X GYP BD ON BOTH SIDES OF

STUD FRAMING, TYP., UNLESS NOTED OTHERWISE.

EXTEND GYP BD TO 6" ABOVE CEILING UNLESS REQUIRED

OTHERWISE. PROVIDE ACCOUSTICAL SEALANT AT TOP

AND BOTTOM OF ALL PENETRATIONS OF WALL WITH

SOUND BATT.

WALLS TO RECEIVE GYPSUM BOARD PRODUCT ON BOTH

FACES OF METAL STUD AND WALLS THAT REQUIRE

ACOUSTICAL SOUND BATT INSULATION SHALL BE

CONSTRUCTED TO MEET A MINIMUM 45 STC UNLESS

OTHERWISE NOTED.

FIRE TAPE AND/OR FILL VOIDS AT TOP OF WALL - FIRE

RATED WALL AS REQUIRED BY CODE - REF. SPEC.

PROVIDE SEALANT AT TOP & BOTTOM AND ALL

PENETRATIONS ON ONE SIDE OF SMOKE PARTITION

WALLS AS REQUIRED BY CODE - REF. SPECS

INSTALL FIRE RATED SEAL/CLOSURE @ ALL OPENINGS,

GAPS AND TOP & BOTTOM OF FRAMING AS SPECIFIED.

BRACE ALL STUD WALLS TO STRUCTURE ABOVE @ 4'-0" O.C.

OR EXTEND ALL STUDS TO DECK ABOVE, TYP.

T - THERMAL

RATING

R - RATED INDICATES WALL IS RATED FOR FIRE,

OCCUPANCY, AND/ OR SMOKE - REF. LIFE SAFETY

SHEETS

RATED

INDICATES WALL THAT EXTEND 6"

ABOVE CEILING

M - WIRE MESH REINFORCEMENT (REF. SPECS.)

3 - 3 5/8" METAL STUD FRAMING

PROVIDE COATED GLASS MAT TILE BACKER BOARD AT ALL

SHOWER & WET AREAS AND AS BACKER FOR CERAMIC WALL TILE.

TOILET & SINK AREAS TO RECEIVE MOISTURE-RESISTANT GYP

BOARD. PROVIDE 20GA. STUDS AS REQUIRED IN TCNA AND GA-216.

ADDITION

REMODEL

AREAS

TRAVEL

E140 AGENT

CASHIER

E142

CORRIDOR

F1F22

WAITING

F174

C O

N S

U L T

F

A

C O

N S

U L T

F

B

C O

N S

U L T

F

C

VAULT

F178

SWAMP

F176

STORAGE

F179

CORRIDOR

F1F23

12' - 6" ±17' - 6"

L3A

L3AMR

B6N

L3A

L3AM

L3A

L3T

L1N

L1N

STAIR #11

F173

F.M.S.

ENG.

F170

PINPOINT

TRAVEL

E144

L3A

B4NR

14' - 10"9' - 4"25' - 3"5' - 11"6' - 7"6' - 10"2' - 6" ±6' - 6"

9' - 6"5' - 5"

2' - 0"

4' - 11"5' - 4"3' - 6"17' - 8"7' - 4"13' - 2"

ACA

ACA

ACA

ACA

10.6

ACA

ACA

11.5

ACA

ACA

H

ACA

G

ACA

E

ACA

D

ACA

C

ACA

E.1

ACA

F

ACA

D.8

ACA

D.7

BID DEDUCT #2

1' - 0"51' - 8"1' - 0"15' - 3"

L3A

L3A

L3N

L3A

L3N

L3AM

L3AM L3AMR

L3N

L1NL3A

L3AR

L1N L0N

L3AR L3AR L3AR

L1N

OFFICE

F175

OFFICE

F164

OFFICE

F162

OFFICE

F161

OFFICE

F160

OFFICE

F159

ACA

10.1

11.8

F.2 F.9 G.5

12.1

/2

/2

CLEAR

4' - 0"

NOT IN SCOPE OF

WORK

NOT IN SCOPE OF WORK

16' - 9" 52' - 8"

E.5

L3AR

B8N

L3AMR

/2

L3NL3N

PHARMACY

WORK

F177

L0N

4' - 6"

L3A

L3N

3' - 7" 15' - 0" 3' - 7"

L3AR

F.1

L3T

L3N L3N L3N

CLEAR

4' - 3 1/2"

L1N

L1N

B8N

B8NR

B8N

L0N

L1N

L3N

L3NL3N

5 555

L3NR

L3NR

L1N

L1N

ELEC

F180

L3NRL3NR

PROTECTIVE WIRE MESH

PROTECTIVE WIRE MESH

L3N

PROTECTIV

E WIRE

MESH

6' - 3 1/2"

L3A L3A L3A L3A

L0N L1N

L3N L3A L3AM L6A B4NR B8N

WIRE MESH

REINFORCEMEN

T

ACOUST. BATT

INSUL.ACOUST. BATT INSUL. ACOUST. BATT INSUL.

7/8" HAT CHANNEL

5/8" TYPE X GYP BD. 1 5/8" MTL. STUD

5/8" TYPE X GYP BD.

5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD.

7/8" HAT CHANNEL

6" CMU

8" CMU

3 5/8" MTL. STUD 3 5/8" MTL. STUD 3 5/8" MTL.

STUD

6" MTL. STUD

L3AR

ACOUST. BATT INSUL.

2X 5/8" TYPE X

GYP BD.

3 5/8" MTL. STUD

SUBSTRATE

T Y

P

T Y

P

T Y

P

CLG. - REF.

CLG. PLANS

CLG. - REF.

CLG. PLANS

CLG. - REF. CLG.

PLANS

CLG. - REF.

CLG. PLANS

CLG. - REF. CLG.

PLANS

CLG. - REF.

CLG. PLANS

CLG. - REF.

CLG. PLANS

B.O. DECK

FIRE RESISTIVE

JOINT SYSTEM

T Y

P

SUBSTRATE

ACOUST. SEALANT

ACOUST. SEALANT

ACOUST. SEALANT ACOUST. SEALANT

ACOUST. SEALANT

ACOUST. SEALANT

ACOUST. SEALANT

CLG. - REF.

CLG. PLANS

B.O. DECK B.O. DECK

B.O. DECKB.O. DECK

B.O. DECKB.O. DECKB.O. DECK

FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR

FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR

DEFLECTIO

N TRACK

DEFLECTION TRACK

DEFLECTION TRACKDEFLECTION TRACK

DEFLECTION TRACK

ACOUST. SEALANT

L1NR

1 5/8" MTL.

STUD

3X 5/8" TYPE

X GYP BD.

CLG. - REF. CLG.

PLANS

B.O. DECK

FINISHED FLOOR

FIRE RESISTIVE

JOINT SYSTEM

DEFLECTION TRACK

ACOUSTICAL

SEALANT

2 HOUR

UL U411

METAL SECURITY

MESH

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

EXPAND PHARMACY AND LOBBY

AS103

FIRST FLOOR - DIMENSIONS PLAN

589-334

04/03/2018

4' 8' 16'

1/8" = 1'-0"

0'

1" = 80'-0"

KEY PLAN FIRST FLOOR

1/8" = 1'-0" A

FIRST FLOOR PLAN - DIMENSIONSN

PLAN NOTES - FLOOR PLAN

# DESCRIPTION

1 REMOVEABLE PORTION OF WALL FOR INSTALLATION OF MEDCAROUSEL

2 RELOCATED KNOX BOX

3 PROVIDE A RAMP AND HANDRAIL, REF. CIVIL

4 ALIGN WALLS

5 ALIGN FACE OF GYP WITH EXIST ADJ. FACE OF GYP

6 PATCH FLOOR AS REQ'D WHERE METAL BASE WAS REMOVED

1 1/2" = 1'-0"

WALL TYPES

ACA

ACA

ACA

ACA

10.6

ACA

ACA

11.5

ACA

ACA

H

ACA

G

ACA

E

ACA

D

ACA

C

ACA

E.1

ACA

F

ACA

D.8

ACA

D.7

ACA

10.1

11.8

F.2 F.9 G.5

12.1

E.5 F.1

CORRIDOR

F1F23

STORAGE

F177

L1N

L1N

L3T

L3T

L1N

L3NR

L1N

BID DEDUCT #2

STAIR #11

F173

1' - 0"51' - 8"1' - 0"15' - 3"

16' - 9" 52' - 8"

L1NL1N

5 555

OFFICE

F164

OFFICE

F162

OFFICE

F161

OFFICE

F160

OFFICE

F159

L3AR L3AR L3AR L3AR

NOT IN SCOPE OF

WORK

NOT IN SCOPE OF WORK

CORRIDOR

F1F22

F.M.S.

ENG.

F170

AGENT

CASHIER

E142

TRAVEL

E140

PINPOINT

TRAVEL

E144

L3A

L3A

L3N

L3AR

B6N

L3A

L3NRL3NR

L3NR

L3NR

L3AR

3' - 7" 15' - 0" 3' - 7"

4' - 6"

12' - 6"17' - 6"

4' - 7" 54' - 8" 2' - 7"

2' - 1"

3' - 10"

L1NRL1NR

L1NR L1NR

L3N 6' - 3 1/2"

L3A

L3A

L3A L3A

L3A L3A

ADDITION

REMODEL

AREAS

WALL MATERIALS

LEGEND FOR WALL TAGS

MATERIAL

WIDTH

S - STRUCTURAL METAL STUDS, 20 ga. OR

HEAVIER, (REF. STRUCT.)

L - LIGHT GAUGE METAL STUDS, 20 ga. INTERIOR, 16 ga.

EXTERIOR (REF. SPECS.)

B - CONCRETE MASONRY UNIT, STANDARD

WEIGHTS FOR EXTERIOR & INTERIOR, UNLESS

NOTED OTHERWISE (REF. STRUCT.)

WALL WIDTHS

0 - 7/8" HAT CHANNEL

1 - 1 5/8" HAT CHANNEL/ STUDS

4 - 4" METAL STUD FRAMING

6 - 6" METAL STUD FRAMING OR CONCRETE MASONRY UNIT

8 - 8" METAL STUD FRAMING OR CONCRETE MASONRY

UNIT

NOTES:

PROVIDE ACCOUSTICAL SEALANT AT TOP & BOTTOM AND ALL

PENETRATIONS OF WALLS WITH SOUND BATT.

ALL STUD FRAMING TO BE 16" O.C., TYP.

PROVIDE SEALANT AT TOP & BOTTOM AND ALL PENETRATIONS OF

SMOKE PARTITION WALLS AS REQUIRED BY CODE.

PROVIDE ALL NEW WALLS THAT GO TO STRUCTURE w/ 1 1/2"

MTL. DEFLECTION TRACK - REF STRUCT.

N - NONE

A - ACC0USTICAL

XXXX

INSULATION

WALL INSULATION

WALL HEIGHT

SHADED WALLS INDICATES WALLS

THAT EXTEND TO DECK

INSTALL 5/8" TYPE X GYP BD ON ONE SIDE OF FURRING,

TYP. INSTALL 5/8" TYPE X GYP BD ON BOTH SIDES OF

STUD FRAMING, TYP., UNLESS NOTED OTHERWISE.

EXTEND GYP BD TO 6" ABOVE CEILING UNLESS REQUIRED

OTHERWISE. PROVIDE ACCOUSTICAL SEALANT AT TOP

AND BOTTOM OF ALL PENETRATIONS OF WALL WITH

SOUND BATT.

WALLS TO RECEIVE GYPSUM BOARD PRODUCT ON BOTH

FACES OF METAL STUD AND WALLS THAT REQUIRE

ACOUSTICAL SOUND BATT INSULATION SHALL BE

CONSTRUCTED TO MEET A MINIMUM 45 STC UNLESS

OTHERWISE NOTED.

FIRE TAPE AND/OR FILL VOIDS AT TOP OF WALL - FIRE

RATED WALL AS REQUIRED BY CODE - REF. SPEC.

PROVIDE SEALANT AT TOP & BOTTOM AND ALL

PENETRATIONS ON ONE SIDE OF SMOKE PARTITION

WALLS AS REQUIRED BY CODE - REF. SPECS

INSTALL FIRE RATED SEAL/CLOSURE @ ALL OPENINGS,

GAPS AND TOP & BOTTOM OF FRAMING AS SPECIFIED.

BRACE ALL STUD WALLS TO STRUCTURE ABOVE @ 4'-0" O.C.

OR EXTEND ALL STUDS TO DECK ABOVE, TYP.

T - THERMAL

RATING

R - RATED INDICATES WALL IS RATED FOR FIRE,

OCCUPANCY, AND/ OR SMOKE - REF. LIFE SAFETY

SHEETS

RATED

INDICATES WALL THAT EXTEND 6"

ABOVE CEILING

M - WIRE MESH REINFORCEMENT (REF. SPECS.)

3 - 3 5/8" METAL STUD FRAMING

PROVIDE COATED GLASS MAT TILE BACKER BOARD AT ALL

SHOWER & WET AREAS AND AS BACKER FOR CERAMIC WALL TILE.

TOILET & SINK AREAS TO RECEIVE MOISTURE-RESISTANT GYP

BOARD. PROVIDE 20GA. STUDS AS REQUIRED IN TCNA AND GA-216.

L0N L1N

L3N L3A L3AM L6A B4NR B8N

WIRE MESH

REINFORCEMEN

T

ACOUST. BATT

INSUL.ACOUST. BATT INSUL. ACOUST. BATT INSUL.

7/8" HAT CHANNEL

5/8" TYPE X GYP BD. 1 5/8" MTL. STUD

5/8" TYPE X GYP BD.

5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD.

7/8" HAT CHANNEL

6" CMU

8" CMU

3 5/8" MTL. STUD 3 5/8" MTL. STUD 3 5/8" MTL.

STUD

6" MTL. STUD

L3AR

ACOUST. BATT INSUL.

2X 5/8" TYPE X

GYP BD.

3 5/8" MTL. STUD

SUBSTRATE

T Y

P

T Y

P

T Y

P

CLG. - REF.

CLG. PLANS

CLG. - REF.

CLG. PLANS

CLG. - REF. CLG.

PLANS

CLG. - REF.

CLG. PLANS

CLG. - REF. CLG.

PLANS

CLG. - REF.

CLG. PLANS

CLG. - REF.

CLG. PLANS

B.O. DECK

FIRE RESISTIVE

JOINT SYSTEM

T Y

P

SUBSTRATE

ACOUST. SEALANT

ACOUST. SEALANT

ACOUST. SEALANT ACOUST. SEALANT

ACOUST. SEALANT

ACOUST. SEALANT

ACOUST. SEALANT

CLG. - REF.

CLG. PLANS

B.O. DECK B.O. DECK

B.O. DECKB.O. DECK

B.O. DECKB.O. DECKB.O. DECK

FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR

FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR

DEFLECTIO

N TRACK

DEFLECTION TRACK

DEFLECTION TRACKDEFLECTION TRACK

DEFLECTION TRACK

ACOUST. SEALANT

L1NR

1 5/8" MTL.

STUD

3X 5/8" TYPE

X GYP BD.

CLG. - REF. CLG.

PLANS

B.O. DECK

FINISHED FLOOR

FIRE RESISTIVE

JOINT SYSTEM

DEFLECTION TRACK

ACOUSTICAL

SEALANT

2 HOUR

UL U411

METAL SECURITY

MESH

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

EXPAND PHARMACY AND LOBBY

AS103.2

FIRST FLOOR - DIMENSIONS PLAN - BID

DEDUCT #2

589-334

04/03/2018

1/8" = 1'-0" A

FIRST FLOOR PLAN - DIMENSIONS BID

DEDUCT #2

N

4' 8' 16'

1/8" = 1'-0"

0'

1" = 80'-0"

KEY PLAN FIRST FLOOR

PLAN NOTES - FLOOR PLAN

# DESCRIPTION

1 REMOVEABLE PORTION OF WALL FOR INSTALLATION OF MEDCAROUSEL

2 RELOCATED KNOX BOX

3 PROVIDE A RAMP AND HANDRAIL, REF. CIVIL

4 ALIGN WALLS

5 ALIGN FACE OF GYP WITH EXIST ADJ. FACE OF GYP

6 PATCH FLOOR AS REQ'D WHERE METAL BASE WAS REMOVED

1 1/2" = 1'-0"

WAITING /

DILATION

E209

DIRTY

E253

ELEC

F252

SWAMP

E215

LASER

E255

TLT

F253

EXAM 1

E226

EXAM 2

E225

EXAM 3

E223

EXAM 4

E222

EXAM 5

E221

EXAM 6

E219

EXAM 7

E218 EXAM 8

E217

FUNDUS

E216

VISUAL

FIELDS

E211

VISUAL

FIELDS

E212

REFRAC

E212A

PROCEDURE

E213

EXAM 9

E220

JAN

E205

EQUIP

E205A

N.S.

E211A

WORK RM.

E224A

REFRAC

E210

IMAGING

F256

EXAM 10

F273

EXAM 22

F258

EXAM 21

F259

EXAM 11

F272

EXAM 12

F271

EXAM 13

F270

EXAM 14

F269

EXAM 18

F262

EXAM 19

F261

EXAM 20

F260

EXAM 15

F267

EXAM 16

F266

EXAM 17

F265

NOT IN SCOPE OF

WORK

OPEN TO

BELOW

3' - 1" ±2' - 5"5' - 6"1' - 11"6' - 3"6' - 3"5' - 0"6' - 4" ±

11' - 4"9' - 9"6' - 5" ±10' - 4"6"6' - 6" ±13' - 0"

CLEAR, TYP

4' - 0"

4' - 10" ±

1' - 9"

8' - 0"

L3N

L3AR

L3A

L3AR

L3A

L3AR

L3A

L3A

L3N

L3A

L3A

L3A

L3A

L3A

L3A L3N

L3A

L3A

L3A

L3N

L3A

L3A

L3N

L3A

L3N

L3N

L3N

L3N

L3A

L3A

L3A

L3N

L3A L3A

L3A

L3A

L3A

L3A

L3A

L3A L3A L3A L3A

L3A

L3A

L3A

L3AR

L

N

L0N

L1N

L3N

CORR

C2E3

CORR

C2E2

CORR

C2E1

CORR

C2F21

WAITING

DILATION

F257

CORR

C2F24

CORR

C2F22

CORR

C2F23

STAIR #11

F248

3 1/2"8' - 3 1/2"5' - 10"7' - 3"9' - 5"9' - 5"9' - 5"9' - 5"9' - 5"2"

L3A

"WAITING

F263

NURSE

F264

WAITING

F268

PRE-

CATARACT

E214

WAITING

E206

CLEAN

E254

ADMIN

OFFICE

F255

ACA

ACA

ACA

ACA

10.6

ACA

ACA

11.5

ACA

ACA

H

ACA

G

ACA

E

ACA

D

ACA

C

ACA

B

ACA

A

ACA

E.1

ACA

F

ACA

B.2

ACA

D.8

ACA

D.7

L1N

L3A L3AL3A

L3A

L3A

L1N

L3A

2' - 6"12' - 6"

L3N

L3A

L3A

L3A

1' - 6"13' - 5"15' - 11"22' - 4"1' - 0"15' - 3"

/2

ACA

10.1

11.8

F.2 F.9 G.5

12.1

52' - 8"16' - 9"

69' - 5"

L3A 3

/2

/2

CLEAR

5' - 1"

L3N L3N L3N

L3N

L3N

L3AR

L3T

L3T

L3T

E.5

HALL

C2E4 4

L3N

L3N

L3N

L3AR

L2T

L3NL3AL1N

L3A

L3A L3A

L3N

L3N

L3N

L3N

11' - 1 1/2"

L3N

F.1

L3A

L3AR

L3AR

L3N

L3AR

EXAM

F247

EXAM

F244

EXAM

F243

EXAM

F241

EXAM

F240

11' - 3" 5' - 0" 6' - 0" 10' - 0" 6' - 0" 5' - 0" 9' - 5"

L3N

1' - 2"

L3A

L3N

L3N

L3N

L3A

8' - 8" L3N L3N

L3N

L3N

BID DEDUCT #

1L1N

INFILL FLOOR SLAB

- REF. STRUCTURAL

SHEET S-102.3

L3A

ADDITION

REMODEL

AREA

WALL MATERIALS

LEGEND FOR WALL TAGS

MATERIAL

WIDTH

S - STRUCTURAL METAL STUDS, 20 ga. OR

HEAVIER, (REF. STRUCT.)

L - LIGHT GAUGE METAL STUDS, 20 ga. INTERIOR, 16 ga.

EXTERIOR (REF. SPECS.)

B - CONCRETE MASONRY UNIT, STANDARD

WEIGHTS FOR EXTERIOR & INTERIOR, UNLESS

NOTED OTHERWISE (REF. STRUCT.)

WALL WIDTHS

0 - 7/8" HAT CHANNEL

1 - 1 5/8" HAT CHANNEL/ STUDS

4 - 4" METAL STUD FRAMING

6 - 6" METAL STUD FRAMING OR CONCRETE MASONRY UNIT

8 - 8" METAL STUD FRAMING OR CONCRETE MASONRY

UNIT

NOTES:

PROVIDE ACCOUSTICAL SEALANT AT TOP & BOTTOM AND ALL

PENETRATIONS OF WALLS WITH SOUND BATT.

ALL STUD FRAMING TO BE 16" O.C., TYP.

PROVIDE SEALANT AT TOP & BOTTOM AND ALL PENETRATIONS OF

SMOKE PARTITION WALLS AS REQUIRED BY CODE.

PROVIDE ALL NEW WALLS THAT GO TO STRUCTURE w/ 1 1/2"

MTL. DEFLECTION TRACK - REF STRUCT.

N - NONE

A - ACC0USTICAL

XXXX

INSULATION

WALL INSULATION

WALL HEIGHT

SHADED WALLS INDICATES WALLS

THAT EXTEND TO DECK

INSTALL 5/8" TYPE X GYP BD ON ONE SIDE OF FURRING,

TYP. INSTALL 5/8" TYPE X GYP BD ON BOTH SIDES OF

STUD FRAMING, TYP., UNLESS NOTED OTHERWISE.

EXTEND GYP BD TO 6" ABOVE CEILING UNLESS REQUIRED

OTHERWISE. PROVIDE ACCOUSTICAL SEALANT AT TOP

AND BOTTOM OF ALL PENETRATIONS OF WALL WITH

SOUND BATT.

WALLS TO RECEIVE GYPSUM BOARD PRODUCT ON BOTH

FACES OF METAL STUD AND WALLS THAT REQUIRE

ACOUSTICAL SOUND BATT INSULATION SHALL BE

CONSTRUCTED TO MEET A MINIMUM 45 STC UNLESS

OTHERWISE NOTED.

FIRE TAPE AND/OR FILL VOIDS AT TOP OF WALL - FIRE

RATED WALL AS REQUIRED BY CODE - REF. SPEC.

PROVIDE SEALANT AT TOP & BOTTOM AND ALL

PENETRATIONS ON ONE SIDE OF SMOKE PARTITION

WALLS AS REQUIRED BY CODE - REF. SPECS

INSTALL FIRE RATED SEAL/CLOSURE @ ALL OPENINGS,

GAPS AND TOP & BOTTOM OF FRAMING AS SPECIFIED.

BRACE ALL STUD WALLS TO STRUCTURE ABOVE @ 4'-0" O.C.

OR EXTEND ALL STUDS TO DECK ABOVE, TYP.

T - THERMAL

RATING

R - RATED INDICATES WALL IS RATED FOR FIRE,

OCCUPANCY, AND/ OR SMOKE - REF. LIFE SAFETY

SHEETS

RATED

INDICATES WALL THAT EXTEND 6"

ABOVE CEILING

M - WIRE MESH REINFORCEMENT (REF. SPECS.)

3 - 3 5/8" METAL STUD FRAMING

PROVIDE COATED GLASS MAT TILE BACKER BOARD AT ALL

SHOWER & WET AREAS AND AS BACKER FOR CERAMIC WALL TILE.

TOILET & SINK AREAS TO RECEIVE MOISTURE-RESISTANT GYP

BOARD. PROVIDE 20GA. STUDS AS REQUIRED IN TCNA AND GA-216.

L0N L1N

L3N L3A L3AM L6A B4NR B8N

WIRE MESH

REINFORCEMEN

T

ACOUST. BATT

INSUL.ACOUST. BATT INSUL. ACOUST. BATT INSUL.

7/8" HAT CHANNEL

5/8" TYPE X GYP BD. 1 5/8" MTL. STUD

5/8" TYPE X GYP BD.

5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD.

7/8" HAT CHANNEL

6" CMU

8" CMU

3 5/8" MTL. STUD 3 5/8" MTL. STUD 3 5/8" MTL.

STUD

6" MTL. STUD

L3AR

ACOUST. BATT INSUL.

2X 5/8" TYPE X

GYP BD.

3 5/8" MTL. STUD

SUBSTRATE

T Y

P

T Y

P

T Y

P

CLG. - REF.

CLG. PLANS

CLG. - REF.

CLG. PLANS

CLG. - REF. CLG.

PLANS

CLG. - REF.

CLG. PLANS

CLG. - REF. CLG.

PLANS

CLG. - REF.

CLG. PLANS

CLG. - REF.

CLG. PLANS

B.O. DECK

FIRE RESISTIVE

JOINT SYSTEM

T Y

P

SUBSTRATE

ACOUST. SEALANT

ACOUST. SEALANT

ACOUST. SEALANT ACOUST. SEALANT

ACOUST. SEALANT

ACOUST. SEALANT

ACOUST. SEALANT

CLG. - REF.

CLG. PLANS

B.O. DECK B.O. DECK

B.O. DECKB.O. DECK

B.O. DECKB.O. DECKB.O. DECK

FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR

FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR

DEFLECTIO

N TRACK

DEFLECTION TRACK

DEFLECTION TRACKDEFLECTION TRACK

DEFLECTION TRACK

ACOUST. SEALANT

L1NR

1 5/8" MTL.

STUD

3X 5/8" TYPE

X GYP BD.

CLG. - REF. CLG.

PLANS

B.O. DECK

FINISHED FLOOR

FIRE RESISTIVE

JOINT SYSTEM

DEFLECTION TRACK

ACOUSTICAL

SEALANT

2 HOUR

UL U411

METAL SECURITY

MESH

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

EXPAND PHARMACY AND LOBBY

AS104

SECOND FLOOR - DIMENSIONS PLAN

589-334

04/03/2018

1/8" = 1'-0" A

SECOND FLOOR PLAN - DIMENSIONS

1" = 80'-0"

KEY PLAN SECOND FLOOR

N

4' 8' 16'

1/8" = 1'-0"

0'

1 1/2" = 1'-0"

ACA

ACA

ACA

ACA

10.6

ACA

ACA

11.5

ACA

ACA

H

ACA

G

ACA

E

ACA

D

ACA

C

ACA

B

ACA

E.1

ACA

F

ACA

B.2

ACA

D.8

ACA

D.7

ACA

10.1

11.8

F.2 F.9 G.5

12.1

E.5 F.1

L1N

NOT IN SCOPE OF WORK

BID DEDUCT #1

AS504

A4A5

INFILL FLOOR SLAB

- REF. STRUCTURAL

SHEET S-102.3

L3N

L3AR

L3A

L3AR

L3A

L3AR

L3A

L3A

L3N

L3A

L3A

L3A

L3A

L3A

L3A L3N

L3A

L3A

L3A

L3N

L3A

L3A

L3N

L3A

L3N

L3N

L3N

L3N

L3A

L3A

L3A

L3N

L3A

L3A L3NR

L3A

L3A

L3A

L3A

L3A L3A L3A L3A

L

AL3AR

L

N

L0N

L1N

L3N

L3A

L1N

L3A

L3N

L3A

L3A

L3A

L3A

L3N

L3AR

L3T

L3T

L3T

L3N

L3N

L3AR

L3NR

L1N

L3N

L3N

L3N

L3N

L3N

L3A

L3AR

L3AR

L3N

L3AR

L3A L3A L3A L3A

WAITING /

DILATION

E209

DIRTY

E253

ELEC

F252

SWAMP

E215

LASER

E255

TLT

F253

EXAM 1

E226

EXAM 2

E225

EXAM 3

E223

EXAM 4

E222

EXAM 5

E221

EXAM 6

E219

EXAM 7

E218 EXAM 8

E217

FUNDUS

E216

VISUAL

FIELDS

E211

VISUAL

FIELDS

E212

REFRAC

E212A

PROCEDURE

E213

EXAM 9

E220

JAN

E205

EQUIP

E205A

N.S.

E211A

WORK RM.

E224A

REFRAC

E210

IMAGING

F256

EXAM 10

F273

EXAM 22

F258

EXAM 21

F259

EXAM 11

F272

EXAM 12

F271

EXAM 13

F270

EXAM 14

F269

EXAM 18

F262

EXAM 19

F261

EXAM 20

F260

STORAGE

BD265

CORR

C2E3

CORR

C2E2

CORR

C2E1

CORR

C2F21

WAITING

DILATION

F257

CORR

C2F24

CORR

C2F22

CORR

C2F23

STAIR #11

F248

WAITING

F263

NURSE

F264

WAITING

F268

PRE-

CATARACT

E214

WAITING

E206

CLEAN

E254

ADMIN

OFFICE

F255

HALL

C2E4

EXAM

F247

EXAM

F244

EXAM

F243

EXAM

F241

EXAM

F240

3' - 1" ±2' - 5"5' - 6"1' - 11"6' - 3"6' - 3"5' - 0"6' - 4" ±

11' - 4"9' - 9"6' - 5" ±10' - 4"6"6' - 6"1' - 11"11' - 2"

CLEAR, TYP

4' - 0"

4' - 10" ±

1' - 9"

8' - 0"

3"8' - 4" ±5' - 10" ±7' - 3"9' - 5"9' - 5"9' - 5"9' - 5"9' - 5"2"

2' - 6"12' - 6"

1' - 5 1/2"13' - 5"15' - 11"22' - 4"1' - 0"15' - 3"

/2

52' - 8"16' - 9"

69' - 4 1/2"

/2

/2

CLEAR

5' - 1"

11' - 2 1/2" 5' - 0" 6' - 0" 10' - 0" 5' - 11 1/2" 5' - 0 1/2" 9' - 5"

L3N

L1NR

L1NR

1' - 2"

L3A

L3N L3N

L3N

AI501

L1N

L3A

L3A

ADDITION

REMODEL

AREA

WALL MATERIALS

LEGEND FOR WALL TAGS

MATERIAL

WIDTH

S - STRUCTURAL METAL STUDS, 20 ga. OR

HEAVIER, (REF. STRUCT.)

L - LIGHT GAUGE METAL STUDS, 20 ga. INTERIOR, 16 ga.

EXTERIOR (REF. SPECS.)

B - CONCRETE MASONRY UNIT, STANDARD

WEIGHTS FOR EXTERIOR & INTERIOR, UNLESS

NOTED OTHERWISE (REF. STRUCT.)

WALL WIDTHS

0 - 7/8" HAT CHANNEL

1 - 1 5/8" HAT CHANNEL/ STUDS

4 - 4" METAL STUD FRAMING

6 - 6" METAL STUD FRAMING OR CONCRETE MASONRY UNIT

8 - 8" METAL STUD FRAMING OR CONCRETE MASONRY

UNIT

NOTES:

PROVIDE ACCOUSTICAL SEALANT AT TOP & BOTTOM AND ALL

PENETRATIONS OF WALLS WITH SOUND BATT.

ALL STUD FRAMING TO BE 16" O.C., TYP.

PROVIDE SEALANT AT TOP & BOTTOM AND ALL PENETRATIONS OF

SMOKE PARTITION WALLS AS REQUIRED BY CODE.

PROVIDE ALL NEW WALLS THAT GO TO STRUCTURE w/ 1 1/2"

MTL. DEFLECTION TRACK - REF STRUCT.

N - NONE

A - ACC0USTICAL

XXXX

INSULATION

WALL INSULATION

WALL HEIGHT

SHADED WALLS INDICATES WALLS

THAT EXTEND TO DECK

INSTALL 5/8" TYPE X GYP BD ON ONE SIDE OF FURRING,

TYP. INSTALL 5/8" TYPE X GYP BD ON BOTH SIDES OF

STUD FRAMING, TYP., UNLESS NOTED OTHERWISE.

EXTEND GYP BD TO 6" ABOVE CEILING UNLESS REQUIRED

OTHERWISE. PROVIDE ACCOUSTICAL SEALANT AT TOP

AND BOTTOM OF ALL PENETRATIONS OF WALL WITH

SOUND BATT.

WALLS TO RECEIVE GYPSUM BOARD PRODUCT ON BOTH

FACES OF METAL STUD AND WALLS THAT REQUIRE

ACOUSTICAL SOUND BATT INSULATION SHALL BE

CONSTRUCTED TO MEET A MINIMUM 45 STC UNLESS

OTHERWISE NOTED.

FIRE TAPE AND/OR FILL VOIDS AT TOP OF WALL - FIRE

RATED WALL AS REQUIRED BY CODE - REF. SPEC.

PROVIDE SEALANT AT TOP & BOTTOM AND ALL

PENETRATIONS ON ONE SIDE OF SMOKE PARTITION

WALLS AS REQUIRED BY CODE - REF. SPECS

INSTALL FIRE RATED SEAL/CLOSURE @ ALL OPENINGS,

GAPS AND TOP & BOTTOM OF FRAMING AS SPECIFIED.

BRACE ALL STUD WALLS TO STRUCTURE ABOVE @ 4'-0" O.C.

OR EXTEND ALL STUDS TO DECK ABOVE, TYP.

T - THERMAL

RATING

R - RATED INDICATES WALL IS RATED FOR FIRE,

OCCUPANCY, AND/ OR SMOKE - REF. LIFE SAFETY

SHEETS

RATED

INDICATES WALL THAT EXTEND 6"

ABOVE CEILING

M - WIRE MESH REINFORCEMENT (REF. SPECS.)

3 - 3 5/8" METAL STUD FRAMING

PROVIDE COATED GLASS MAT TILE BACKER BOARD AT ALL

SHOWER & WET AREAS AND AS BACKER FOR CERAMIC WALL TILE.

TOILET & SINK AREAS TO RECEIVE MOISTURE-RESISTANT GYP

BOARD. PROVIDE 20GA. STUDS AS REQUIRED IN TCNA AND GA-216.

L0N L1N

L3N L3A L3AM L6A B4NR B8N

WIRE MESH

REINFORCEMEN

T

ACOUST. BATT

INSUL.ACOUST. BATT INSUL. ACOUST. BATT INSUL.

7/8" HAT CHANNEL

5/8" TYPE X GYP BD. 1 5/8" MTL. STUD

5/8" TYPE X GYP BD.

5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD. 5/8" TYPE X GYP BD.

7/8" HAT CHANNEL

6" CMU

8" CMU

3 5/8" MTL. STUD 3 5/8" MTL. STUD 3 5/8" MTL.

STUD

6" MTL. STUD

L3AR

ACOUST. BATT INSUL.

2X 5/8" TYPE X

GYP BD.

3 5/8" MTL. STUD

SUBSTRATE

T Y

P

T Y

P

T Y

P

CLG. - REF.

CLG. PLANS

CLG. - REF.

CLG. PLANS

CLG. - REF. CLG.

PLANS

CLG. - REF.

CLG. PLANS

CLG. - REF. CLG.

PLANS

CLG. - REF.

CLG. PLANS

CLG. - REF.

CLG. PLANS

B.O. DECK

FIRE RESISTIVE

JOINT SYSTEM

T Y

P

SUBSTRATE

ACOUST. SEALANT

ACOUST. SEALANT

ACOUST. SEALANT ACOUST. SEALANT

ACOUST. SEALANT

ACOUST. SEALANT

ACOUST. SEALANT

CLG. - REF.

CLG. PLANS

B.O. DECK B.O. DECK

B.O. DECKB.O. DECK

B.O. DECKB.O. DECKB.O. DECK

FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR

FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR

DEFLECTIO

N TRACK

DEFLECTION TRACK

DEFLECTION TRACKDEFLECTION TRACK

DEFLECTION TRACK

ACOUST. SEALANT

L1NR

1 5/8" MTL.

STUD

3X 5/8" TYPE

X GYP BD.

CLG. - REF. CLG.

PLANS

B.O. DECK

FINISHED FLOOR

FIRE RESISTIVE

JOINT SYSTEM

DEFLECTION TRACK

ACOUSTICAL

SEALANT

2 HOUR

UL U411

METAL SECURITY

MESH

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

JUAR

Columbia, Missouri

EXPAND PHARMACY AND LOBBY

AS104.1

SECOND FLOOR - DIMENSIONS PLAN - BID

DEDUCT #1

589-334

04/03/2018

1/8" = 1'-0" A

SECOND FLOOR PLAN - DIMENSIONS -

BID DEDUCT #1

N

4' 8' 16'

1/8" = 1'-0"

0'

1" = 80'-0"

KEY PLAN SECOND FLOOR

1 1/2" = 1'-0"

11.8

F.2

5/8" TYPE X GYP. BD. ON 7/8"

MTL. HAT CHANNEL

LIQUID APPLIED AIR/WATER

BARRIER - REF. SPECS.

5/8" EXT.GYP. BD.

SHEATHING

6" FOIL FACED BATT. INSUL.

5/8" GYP. BD. ON 6"

MTL. STUD @ 16" O.C.

CAST STONE - MATCH

EXIST. - REF. SPECS..

CAULK - TYP.

2HR COLUMN WRAP - UL DESIGN X528 - REF. SPECS.

COLUMN - REF. STRUCTURAL

ACA

H

11.8

LIQUID APPLIED AIR/WATER

BARRIER - REF. SPECS.

5/8" GYP. BD. SHEATHING

6" FOIL FACED BATT. INSUL.

5/8" TYPE X GYP. BD.

ON 6" MTL. STUD @ 16"

O.C.

CAST STONE - MATCH

EXIST. - REF. SPECS.

CAULK - TYP.

5/8" GYP BD. ON

BENT 1 5/8" MTL.

STUD

2HR COLUMN WRAP - UL

DESIGN X528 - REF. SPECS.

11.8

F.9

CAULK - TYP.

5/8" EXT. GYP BD. ON 6"

MTL. STUD @ 16" O.C.

LIQUID APPLIED

AIR/WATER BARRIER -

REF. SPECS.

CAST STONE - MATCH

EXIST. - REF. SPECS.

FOIL FACED 6"

BATT. INSUL.

2HR COLUMN WRAP - UL

DESIGN X528 - REF.

SPECS.

COLUMN - REF.

STRUCTURAL

5/8" GYP BD ON 1 5/8" MTL

STUD

ACA

H

10.1

5/8" TYPE X GYP BD. ON

3 5/8" MTL. STUDS @

16" O.C.

CAULK - TYP.

2HR COLUMN WRAP - UL

DESIGN X528 - REF.

SPECS. ANODIZED ALUM.

STOREFRONT SYSTEM W/ 1"

INSUL GLAZING - REF SPEC

LIQUID APPLIED AIR/WATER

BARRIER - REF. SPECS.

5/8" GYP. BD. SHEATHING

6" FOIL FACED BATT. INSUL.

CAST STONE - MATCH EXIST.

ADJ. - REF. SPECS.

COLUMN, REF. STRUCTURAL

WIRE MESH

REINFORCIN

G

5/8" TYPE X GYP BD. ON

3 5/8" MTL. STUDS @

16" O.C.

11.8

G.5

CAULK - TYP.

2HR COLUMN WRAP - UL

DESIGN X528 - REF.

SPECS.

LIQUID APPLIED AIR/WATER

BARRIER - REF. SPECS.

CAST STONE - MATCH EXIST.

ADJ. - REF. SPECS.

6" FOIL FACED BATT. INSUL.

5/8" TYPE X GYP.

BD. ON 3 5/8" MTL.

STUD @ 16" O.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.