This document contains the results of a pre-renovation asbestos inspection and an accompanying federal contract opportunity notice. The inspection report identifies asbestos-containing materials found in various rooms on the third floor of the B-Wing at the William S. Middleton Memorial Veterans Hospital in Madison, Wisconsin, including pipe insulation, floor tiles, mastic, fire doors, and panel adhesives. The federal contract opportunity is to renovate approximately 10,000 square feet of space on the third floor B-Wing. The solicitation number is 36C25220B0010 for Project 607-15-101 to renovate the 3B Inpatient Unit. Work includes demolition, hazardous material removal and disposal, interior finishes, windows, doors, mechanical and electrical systems. The opportunity is set aside for Service-Disabled Veteran-Owned Small Businesses. The solicitation will be issued on January 17, 2020 with bids due February 19, 2020. The project value is estimated between $2-5 million under NAICS 236220. The completion period is 365 calendar days after notice to proceed.
36C25220B0010 0001 S06 - Pre-Renovation Asbestos Inspection-VA Hospital Third Floor B-Wing Revised 10_10_17.pdf
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS PRE-RENOVATION INSPECTION
VA HOSPITAL – MADISON
MADISON, WISCONSIN
THIRD FLOOR RENOVATION
INSPECTION DATE: OCTOBER 4, 2013
REPORT DATE: NOVEMBER 1, 2013
REVISED: OCTOBER 10, 2017
EMC PROJECT NUMBER: 130381-01
PREPARED FOR:
NAGEL ARCHITECTS
13100 WATERTOWN PLANK ROAD
SUITE 200
ELM GROVE, WI 53122
PREPARED BY:
ENVIRONMENTAL MANAGEMENT CONSULTING, INC.
W7748 COUNTY HIGHWAY V
LAKE MILLS, WI 53551
"ACCOMPANYING AMENDMENT – 36C25220B0010 – 0001"
ASBESTOS PRE-RENOVATION INSPECTION
VA-Madison Third Floor Renovation B – Wing Third Floor
Environmental Management Consulting, Inc. (EMC) was contacted by Nagel Architects to conduct a pre-renovation asbestos survey of an area of the VA Hospital located in Madison, WI.
Mr. Jeremy Noegel of EMC inspected the subject property on October 4, 2013. The building was inspected for the presence of asbestos containing building materials. Bulk samples were extracted for each building material found suspect to contain asbestos that has not been previously sampled in a past inspection. All samples were submitted to a NVLAP certified laboratory for analysis via Polarized Light Microscopy (PLM). This report will summarize the findings of this inspection.
The only area of the building inspected at this time was the 3rd Floor B Wing. The following is a summary of the findings of this inspection.
ASBESTOS CONTAINING MATERIALS (ACM)
The following is a summary of materials identified to contain >1% asbestos or assumed to contain asbestos.
1) Asbestos Containing Pipe Insulation (Previously Sampled)
Material Code: TA5, TC5 & TM5
The existing pipe insulation (Aircell type, cardboard type and magnesia type) have been previously tested during past inspections and determined to contain asbestos.
This material is friable and mainly found above ceilings and inside wall chases.
There is approximately 1800 LF of asbestos containing pipe insulation located throughout this area.
2) Asbestos Containing Pipe Fitting Insulation (Previously Sampled) Material Code: TF5F
The existing pipe fitting insulation located on fiberglass straight run insulation was previously tested during a past inspection and identified to contain asbestos. There are approximately 15 asbestos containing pipe fittings located in this area.
3) 9” Floor Tile & Adhesives Material Code: MF9
The 9” floor tile and adhesives found throughout this area were both found to contain asbestos. This material is located throughout much of the area, and much of the 9” floor tile is covered with a second layer of flooring. Because of this condition it is impossible to determine the approximate quantity of this material.
4) 12” Floor Tile & Adhesives Material Code: MF12
The 12” floor tile is located throughout much of this area. The 12” floor tile was found positive for asbestos, however, the yellow mastic was found negative. In many areas this 12” floor tile was applied over the 9” floor tile (ACM) or applied over the old black mastic from the 9” tile (ACM).
5) Ceramic Tile With Yellow Adhesive Material Code: MCTM(1)
This material is located inB3095 Toilet/Bath/Shower rooms. This material is covered with a second layer of ceramic tile. The yellow adhesive was found to contain asbestos.
6) Fire Doors Material Code: MFD
Fire doors are located in the corridor on the third floor. The core of these doors is assumed to contain asbestos.
7) Black Paneling Adhesives Material Codes: MPM
The material is located above the ceiling, on the wall in room B3079. (Not listed in summary below)
Summary of Asbestos Containing Materials
The following is a summary of asbestos containing materials in the third floor “B” Wing.
Much of the flooring is assumed to be present below a second layer of flooring. Most of the piping is located inside walls and chases. The quantities are approximations based on past experience in the facility.
Asbestos Containing Asbestos Containing Asbestos Containing Room Pipe Insulation Floor Tile Ceramic Tile/Mortar
B3056 34 LF 185 SF
B3056 PC 108 LF
B3057 60 LF 185 SF
B3058 30 LF 155 SF
B3059 60 LF 185 SF
B3060 34 LF
B3061 34 LF
B3062 24 LF
B3063 34 LF 150 SF
B3064 34 LF 150 SF
B3064A 24 LF
B3065 150 SF
B3066 50 SF
B3067 34 LF 150 SF
B3069 60 LF 185 SF
B3070 60 LF 185 SF
B3071 60 LF 155 SF
B3072 155 SF
B3073 24 LF
B3074 60 LF 235 SF
B3075 180 SF
B3076 180 SF
B3077 144 SF
B3078 56 LF
B3079 20 LF
B3079A 30 LF
B3079B 20 LF
B3080 18 LF 150 SF
B3081 90 LF
B3082 34 LF 150 SF
B3083 75 LF 115 SF
B3084 30 LF
B3085 48 LF 125 SF
B3086 48 LF
B3087 2 LF 55 SF
Asbestos Containing Asbestos Containing Asbestos Containing Room Pipe Insulation Floor Tile Ceramic Tile/Mortar
B3088 310 SF
B3088A 48 LF 46 SF
B3090 80 SF
B3091 25 SF
B3092 56 SF
B3093 48 LF
B3095/A/B 145 LF 376 SF
B3098 26 LF 24 SF
B3099 34 LF 180 SF
B3100 60 LF 180 SF
B3101 60 LF 90 SF
B3101A 80 SF
B3102 68 LF 360 SF
B3106 120 LF
B3152 Corridor 1,920 SF Stairs #1 60 LF
These materials must be removed by personnel certified by the Department of Health Services, if they are likely to be disturbed during the renovation project. Removal is not necessary if the materials will not be disturbed during the project.
NON-ASBESTOS MATERIALS
The following is a summary of materials, which have been sampled and found not to contain asbestos.
Third Floor Wing B
Material Material Code Description
MDW Drywall and Joint Compound MCTM(2) Ceramic Wall Tile, Grout and Adhesives MV6N 6” Vinyl Base (Brown) and Adhesives MSCT1 2’x2’ Ceiling Tile – Revealed Edge MCLKY* Duct Caulk-Gray MCLKW Sink Caulk - White MCLKT Wall Caulk – Tan
*Note – This material was sampled earlier with a positive result indicated by the laboratory. After discussion with the laboratory regarding this sample, it was determined that the sample may have been contaminated from a different source and additional sampling was recommended. Three additional samples were collected, all with negative results. Therefore, the material was determined to be negative for asbestos.
No work is necessary for these materials.
ADDITIONAL REQUIREMENTS
If this renovation will involve the removal of greater than 160 square feet or 260 linear feet of asbestos containing materials a “Notification of Demolition and/or Renovation and Application for Exemption” (Form 4500-113) must be submitted to the Wisconsin Department of Natural Resources (WDNR). Residential property as defined by the WDNR chapter 447 may be exempt from notification requirements. However, if any amount of asbestos removal is required for the project, the above stated notification will be required to be submitted to the Wisconsin Department of Health Services. The owner/operator is responsible for submitting all notifications.
If during the course of renovation, suspect materials are found, that have not been identified or sampled, work must stop, and a State of Wisconsin Certified Asbestos Building Inspector must be contacted to assess the material. There are inaccessible areas within the building that could not be accessed during the inspection, which could result in additional suspect materials discovered.
All bulk sampling information including a bulk sample chart and the laboratory results are attached to this report. Please contact the EMC office if you have any questions.
Jeremy Noegel
AII-105450
EMC
BULK SAMPLE RESULTS
EMC Project Number: 130381-01 Inspector Number: AII-1283
SAMPLE HOMO MATERIAL ROOM/ SPECIFIC LAB
NUMBER CODE DESCRIPTION AREA SAMPLE LOCATION RESULTS
9" Floor Tile with Tile: 4% Chrysotile VA3-01 MF9 Black Adhesive B307AA At Wall to B3078 Mastic: 8% Chrysotile
9" Floor Tile with Tile: 4% Chrysotile VA3-02 MF9 Black Adhesive B3080 At Doorway Mastic: 8% Chrysotile
12" Beige & Brown Tile: 3% Chrysotile VA3-03 MF12 Floor Tile with Yallow Adhesive B3080 At Doorway Mastic: Negative
12" Beige & Brown Tile: 3% Chrysotile VA3-04 MF12 Floor Tile with Yallow Adhesive B3081 Near Doorwat Mastic: Negative
VA3-05 MDW Drywall & Joint Compound B3073 Southwest Outer Corner Negative
VA3-06 MDW Drywall & Joint Compound B3071 Southeast Outer Corner Negative 6" Brown Vinyl
VA3-07 MV6N Base & Adhesive B3154 Corr Outside B3084 Negative 6" Brown Vinyl
VA3-08 MV6N Base & Adhesive B3154 Corr Outside B3081 Negative 2'x2' Ceiling Tile
VA3-09 MSCT1 Revealed Edge B3082 Center of Room Negative 2'x2' Ceiling Tile
VA3-10 MSCT1 Revealed Edge B3154 Corr Outside B3088 Negative
VA3-11 MCLKY Duct Caulk-Gray B3082 Center of Room above Ceiling *3% Chrysotile
BULK SAMPLE CHART
Sample Date: February 8, 2013 Sample Location: VA-Madison 3rd Floor Sampling Personnel: John T. Bushman
Lab Order ID: 1302157
Project: VA-Madison, 3rd Floor 130381-01
Date Received: 2/11/2013
Date Reported: 2/14/2013
Sample ID Lab Sample ID
Description Lab Notes
Asbestos Fibrous Components
Non-Fibrous Components
Attributes
Treatment
Bulk Asbestos Analysis By Polarized Light Microscopy
EPA Method: 600/R-93/116 and 600/M4-82-020
Attn: John Bushman Analysis ID: 1302157PLM
Customer: Environmental Management Consulting W7748 Cnty Hwy V Lake Mills, WI 53551
VA3-01 - A 9" FT w/blk adh tile
White Non Fibrous Heterogeneous
Dissolved1302157PLM_1
4% Chrysotile 96% Other
VA3-01 - B 9" FT w/blk adh mastic
Black Non Fibrous Homogeneous
Dissolved1302157PLM_12
8% Chrysotile 92% Other
VA3-02 - A 9" FT w/blk adh tile
White Non Fibrous Heterogeneous
Dissolved1302157PLM_2
4% Chrysotile 96% Other
VA3-02 - B 9" FT w/blk adh mastic
Black Non Fibrous Homogeneous
Dissolved1302157PLM_13
8% Chrysotile 92% Other
VA3-03 - A 12" Beige & brn FT w/yellow adh tile
Beige Non Fibrous Heterogeneous
Dissolved1302157PLM_3
3% Chrysotile 97% Other
VA3-03 - B 12" Beige & brn FT w/yellow adh mastic
Yellow Non Fibrous Homogeneous
Dissolved1302157PLM_14
100% Other
None Detected
VA3-04 - A 12" Beige & brn FT w/yellow adh tile
Beige Non Fibrous Heterogeneous
Dissolved1302157PLM_4
3% Chrysotile 97% Other
VA3-04 - B 12" Beige & brn FT w/yellow adh mastic
Yellow Non Fibrous Homogeneous
Dissolved1302157PLM_15
100% Other
None Detected
Nathaniel Durham, MS or Approved SignatoryAnalyst Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommended that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.
Sharon Donald (21)
Date Received: 2/11/2013
Date Reported: 2/14/2013
Sample ID Lab Sample ID
Description Lab Notes
Asbestos Fibrous Components
Non-Fibrous Components
Attributes
Treatment
Bulk Asbestos Analysis By Polarized Light Microscopy
EPA Method: 600/R-93/116 and 600/M4-82-020
Attn: John Bushman Analysis ID: 1302157PLM
Customer: Environmental Management Consulting W7748 Cnty Hwy V Lake Mills, WI 53551
VA3-05 - A Drywall & joint compound drywall
White, Brown Fibrous Heterogeneous
Teased1302157PLM_5
10% 5%
Cellulose Fiber Glass
85% Gypsum
None Detected
VA3-05 - B Drywall & joint compound joint compound
White Non Fibrous Homogeneous
Crushed1302157PLM_16
100% Other
None Detected
VA3-05 - C Drywall & joint compound composite
White, Brown Fibrous Heterogeneous
Crushed1302157PLM_17
10% 5%
Cellulose Fiber Glass
55% 30%
Gypsum Other
None Detected
VA3-06 - A Drywall & joint compound drywall
White, Brown Fibrous Heterogeneous
Teased1302157PLM_6
10% 5%
Cellulose Fiber Glass
85% Gypsum
None Detected
VA3-06 - B Drywall & joint compound joint compound
White Non Fibrous Homogeneous
Crushed1302157PLM_18
100% Other
None Detected
VA3-06 - C Drywall & joint compound composite
White, Brown Fibrous Heterogeneous
Teased1302157PLM_19
10% 5%
Cellulose Fiber Glass
55% 30%
Gypsum Other
None Detected
VA3-07 - A 6" Brown vinyl base & adh vinyl base
Brown Non Fibrous Homogeneous
Ashed1302157PLM_7
100% Other
None Detected
VA3-07 - B 6" Brown vinyl base & adh mastic
Cream Non Fibrous Homogeneous
Dissolved1302157PLM_20
100% Other
None Detected
Nathaniel Durham, MS or Approved SignatoryAnalyst Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommended that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.
Date Received: 2/11/2013
Date Reported: 2/14/2013
Sample ID Lab Sample ID
Description Lab Notes
Asbestos Fibrous Components
Non-Fibrous Components
Attributes
Treatment
Bulk Asbestos Analysis By Polarized Light Microscopy
EPA Method: 600/R-93/116 and 600/M4-82-020
Attn: John Bushman Analysis ID: 1302157PLM
Customer: Environmental Management Consulting W7748 Cnty Hwy V Lake Mills, WI 53551
VA3-08 - A 6" Brown vinyl base & adh vinyl base
Brown Non Fibrous Homogeneous
Ashed1302157PLM_8
100% Other
None Detected
VA3-08 - B 6" Brown vinyl base & adh mastic
Cream Non Fibrous Homogeneous
Dissolved1302157PLM_21
100% Other
None Detected
VA3-09 2'X2' ceiling tile revealed edge White, Gray Fibrous Heterogeneous
Teased1302157PLM_9
50% 30%
Cellulose Mineral Wool
10% 10%
Perlite Other
None Detected
VA3-10 2'X2' ceiling tile revealed edge White, Gray Fibrous Heterogeneous
Teased1302157PLM_10
50% 30%
Cellulose Mineral Wool
10% 10%
Perlite Other
None Detected
VA3-11 Duct caulk - grey Gray Non Fibrous Homogeneous
Dissolved1302157PLM_11
3% Chrysotile 97% Other
Nathaniel Durham, MS or Approved SignatoryAnalyst Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommended that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.
EMC Project Number: 130381-01 Inspector Number: AII-105450
SAMPLE HOMO MATERIAL ROOM/ SPECIFIC LAB
NUMBER CODE DESCRIPTION AREA SAMPLE LOCATION RESULTS
VA3-12 MPM Panel Adhesive (Black) B3079 Above Entrance 8% Chrysotile
VA3-13 MPM Panel Adhesive (Black) B3079 Above Entrance 8% Chrysotile Duct Caulk (Gray)
VA3-14 MCLKY on New Ducting B3082 Middle of Room Negative Duct Caulk (Gray)
VA3-15 MCLKY on New Ducting B3071 By Entrance Negative Duct Caulk (Gray)
VA3-16 MCLKY on New Ducting B3099 By Entrance Negative
VA3-17 MCLKW Sink Caulk (White) B3095B By Sink Negative
VA3-18 MCLKW Sink Caulk (White) B3083 Southeast Corner Negative
VA3-19 MCLKW Sink Caulk (White) B3082 By Sink Negative
VA3-20 MCLKT Wall Caulk (Tan) B3071 Southwest Corner Negative
VA3-21 MCLKT Wall Caulk (Tan) B3071 Southwest Corner Negative Tile: Negative
Ceramic Floor Tile Grout: Negative VA3-22 MCTM(1) Grout & Adhesive B3095 North-Middle Mastic: 3% Chrysotile
Ceramic Floor Tile VA3-23 MCTM(1) Grout & Adhesive B3095 South-Middle Negative
Ceramic Wall Tile VA3-24 MCTM(2) Grout & Adhesive B3095 By Entrance to B3095A Negative
Ceramic Wall Tile VA3-25 MCTM(2) Grout & Adhesive B3072 Middle-West Wall Negative
Terrazzo VA3-26 MSMKY (Black & Gray) B3071 Middle-North Negative
Terrazzo VA3-27 MSMKY (Black & Gray) B3083 Southeast Corner Negative
BULK SAMPLE CHART
Sample Date: October 3, 2013 Sample Location: VA-Madison 3rd Floor Sampling Personnel: Jeremy R. Noegel
1318097Lab Order ID:
VA Madison 3rd Floor 130381-01Project:
10/4/2013Date Received:
10/4/2013Date Reported:
Sample ID Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
By Polarized Light Microscopy EPA Method: 600/R-93/116 and 600/M4-82-020
Jeremy NoegelAttn:
1318097_PLMAnalysis ID:
Customer: Environmental Management Consulting W7748 Cnty Hwy V Lake Mills WI 53551
8% ChrysotileVA-12 Panel adhesive (black) Black Non Fibrous Heterogeneous
Dissolved1318097PLM_1
Other92%
8% ChrysotileVA-13 Panel adhesive (black) Black Non Fibrous Heterogeneous
Dissolved1318097PLM_2
Other92%
None DetectedVA-14 Duct caulk (gray) on new ducting
Gray Non Fibrous Heterogeneous
Dissolved1318097PLM_3
Other100%
None DetectedVA-15 Duct caulk (gray) on new ducting
Gray Non Fibrous Heterogeneous
Dissolved1318097PLM_4
Other100%
None DetectedVA-16 Duct caulk (gray) on new ducting
Gray Non Fibrous Heterogeneous
Dissolved1318097PLM_5
Other100%
None DetectedVA-17 Sink caulk (white) White Non Fibrous Heterogeneous
Ashed1318097PLM_6
Other100%
None DetectedVA-18 Sink caulk (white) White Non Fibrous Heterogeneous
Ashed1318097PLM_7
Other100%
None DetectedVA-19 Sink caulk (white) White Non Fibrous Heterogeneous
Ashed1318097PLM_8
Other100%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommended that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.
Approved SignatoryAnalyst Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Ired Gulley (25) plm_3.3.008
10/4/2013Date Received:
10/4/2013Date Reported:
Sample ID Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
By Polarized Light Microscopy EPA Method: 600/R-93/116 and 600/M4-82-020
Jeremy NoegelAttn:
1318097_PLMAnalysis ID:
Customer: Environmental Management Consulting W7748 Cnty Hwy V Lake Mills WI 53551
None DetectedVA-20 Wall caulk (tan) Tan Non Fibrous Heterogeneous
Dissolved1318097PLM_9
Cellulose Other3% 97%
None DetectedVA-21 Wall caulk (tan) Tan Non Fibrous Heterogeneous
Dissolved1318097PLM_10
Cellulose Other3% 97%
None DetectedVA-22 - A Ceramic floor tile grout & adhesive tile
Beige Non Fibrous Heterogeneous
Crushed1318097PLM_11
Other100%
None DetectedVA-22 - B Ceramic floor tile grout & adhesive grout
Gray Non Fibrous Heterogeneous
Crushed1318097PLM_18
Other Quartz
90% 10%
3% ChrysotileVA-22 - C Ceramic floor tile grout & adhesive mastic
Yellow Non Fibrous Heterogeneous
Dissolved1318097PLM_19
Cellulose Other5% 92%
None DetectedVA-23 - A Ceramic floor tile grout & adhesive beige tile
Beige Non Fibrous Heterogeneous
Crushed1318097PLM_12
Other100%
None DetectedVA-23 - B Ceramic floor tile grout & adhesive black tile
Blue Non Fibrous Heterogeneous
Crushed1318097PLM_20
Other100%
None DetectedVA-23 - C Ceramic floor tile grout & adhesive grout
Gray Non Fibrous Heterogeneous
Dissolved1318097PLM_21
Other100%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommended that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.
Approved SignatoryAnalyst Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Ired Gulley (25)
10/4/2013Date Received:
10/4/2013Date Reported:
Sample ID Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
By Polarized Light Microscopy EPA Method: 600/R-93/116 and 600/M4-82-020
Jeremy NoegelAttn:
1318097_PLMAnalysis ID:
Customer: Environmental Management Consulting W7748 Cnty Hwy V Lake Mills WI 53551
None DetectedVA-23 - D Ceramic floor tile grout & adhesive mastic
Yellow Non Fibrous Heterogeneous
Dissolved1318097PLM_22
Cellulose Other5% 95%
None DetectedVA-24 - A Ceramic wall tile grout & adhesive tile
Tan Non Fibrous Heterogeneous
Crushed1318097PLM_13
Other100%
None DetectedVA-24 - B Ceramic wall tile grout & adhesive grout
Gray Non Fibrous Heterogeneous
Crushed1318097PLM_23
Other100%
None DetectedVA-24 - C Ceramic wall tile grout & adhesive mastic
Yellow Non Fibrous Heterogeneous
Dissolved1318097PLM_24
Cellulose Other3% 97%
None DetectedVA-25 - A Ceramic wall tile grout & adhesive tile
Tan Non Fibrous Heterogeneous
Crushed1318097PLM_14
Other100%
None DetectedVA-25 - B Ceramic wall tile grout & adhesive mastic
Yellow Non Fibrous Heterogeneous
Dissolved1318097PLM_25
Cellulose Other5% 95%
None DetectedVA-26 Terrazzo (black & gray) Gray, Black Non Fibrous Heterogeneous
Crushed1318097PLM_15
Other100%
None DetectedVA-27 Terrazzo (black & gray) Gray, Black Non Fibrous Heterogeneous
Crushed1318097PLM_16
Other100%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommended that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.
Approved SignatoryAnalyst Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Ired Gulley (25)
10/4/2013Date Received:
10/4/2013Date Reported:
Sample ID Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
By Polarized Light Microscopy EPA Method: 600/R-93/116 and 600/M4-82-020
Jeremy NoegelAttn:
1318097_PLMAnalysis ID:
Customer: Environmental Management Consulting W7748 Cnty Hwy V Lake Mills WI 53551
None DetectedVA-28 Terrazzo (black & gray) Gray, Black Non Fibrous Heterogeneous
Crushed1318097PLM_17
Other100%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommended that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.
Approved SignatoryAnalyst Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Ired Gulley (25)
CERTIFICATIONS
| Pre-Renovation Asbestos Inspection Results.pdf |
| ASBESTOS PRE-RENOVATION INSPECTION |
| Material Material |
| Code Description |
| ADDITIONAL REQUIREMENTS |
| BULK SAMPLE RESULTS |
| Bulk Sample Chart 2-8-13.pdf |
| Sheet1 |
| Bulk Sample Chart 10-3-13.pdf |
| Sheet1 |
File details come from the government source that posted it. Updated .