1-AE115 - PHASE B1 NEW WORK PLAN R1.pdf

PDF 3 MB Posted

Attached to
4110--Equipment - Walk-in Coolers/Freezers - Ann Arbor
Solicitation number
36C25025Q0398
Issued by

About this file

This document is an architectural drawing (1-AE115) for a Phase B1 New Work Plan at the Ann Arbor VA Medical Center in Michigan, detailing basement upgrade and renovation work. The plan includes specific modifications to various spaces such as storage areas, freezers, coolers, mechanical rooms, and corridors, with key elements including new walk-in freezer and cooler installations with insulated panel floors and ramps, installation of emergency management carts, free-standing racks, stainless steel work surfaces, and various equipment placement details. The drawing provides precise room measurements, equipment locations, and notes for work to be performed by equipment manufacturers and other contractors, with the project phase focused on upgrading the basement of Building 1 West at the medical center.

View the file

Other files

File Type Posted
28-AE111 - PHASE A2 NEW WORK PLAN.pdf PDF
36C25025Q0398 0002.docx DOCX document
1-AE116 - PHASE B2 NEW WORK PLAN.pdf PDF
36C25025Q0398 0001.docx DOCX document
36C25025Q0398.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

A

M

N P Q R

4 4

UP

UP

/4

N&FS

STORAGE

BB09A

BB13B

BB13

BIO MED

BB09B

N&FS

FREEZER

BB09A

CANTEEN

FREEZER

VESTIBULE

BB09

CANTEEN

COOLER

PATRIOT CAFE

STORAGE

7' - 0"

927 SF

N&FS DRY

BB18

293 SF

MECHANICAL

AB21A

RADIATION

SAFETY

STORAGE

AB31

RADIATION

SAFETY

STORAGE

AB33

ELEC.

AB35

CORRIDOR

C1

STAIR #5

STORAGE

AB39

FLAMMABLE

WASTE

A37C

EXIT STAIR

MECHANICAL

AB37A

AB37B

AB37

FLAMMABLE

WASTE

FLAMMABLE

WASTE

STORAGE

CLOSET

495 SF

N&FS FREEZER

BB18A

TYP.

TYP.

TYP.

TYP.

18' - 0"

TYP.

TYP.

DOCK CORRIDOR

C3.5

T8

254 SF

N&FS COOLER

BB18C

/2

/4

18' - 4"

19' - 4"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

/2

/2

:0

:0

A

M

1-AE115

PHASE B1 NEW WORK PLAN

01/13/2023

UPGRADE BASEMENT,

BUILDING 1 WEST

506-20-102

ANN ARBOR, MICHIGAN

BID DOCUMENTS

1W

ANN ARBOR VA

MEDICAL

CENTER

Approved: Veteran's Affairs Medical Center

1/4" = 1'-0"

ENLARGED NEW WORK PLAN - PHASE B1

KEYPLAN

D R A W I N G N O T E S -

FOR WORK PROVIDED BY EQUIPMENT MANUFACTURER

1 NO NEW WORK IN THIS AREA.

2 NEW FLUSH MOUNTED FLOOR ACCESS DOOR FOR EXISTING 24" X 24" FLOOR OPENING TO SUB-BASEMENT.

3 ALIGN NEW WALL FLUSH WITH ADJACENT WALL

4 DASHED LINE OF FUTURE OPENING

5 NEW COOLER / FREEZER CONDENSER UNITS

11 15" X 10" SCALE (VV).

STANDARDS FOR SHELF MOUNTING AT 3'-8" TO 6'-8" A.F.F. - PROVIDE THREE SHELVES STACKED (CC)."

20 METAL COVER CLIP.

21 PROVIDE PREFABRICATED TEMPORARY CONSTRUCTION SMOKE PARTITION WALL TO TERMINATE

EXISTING CEILING. EXISTING CEILING TO REMAIN. IF ADJACENT SURFACES ARE DISTURBED, CONTRACTOR

TO PATCH AND REPAIR.

22 PROVIDE TEMPORARY CONSTRUCTION SIGNAGE - SEE DETAIL 4/GI003. INSTALL SIGNAGE TEMPORARILY SECURED TO DOOR AT

5'-0" A.F.F. REMOVE AT CONCLUSION OF CONSTRUCTION PHASE.

23 INFILL OPENING WITH CMU. MATCH EXISTING INTERIOR FINISH.

24 (DELETED)

27 FULLY RECESSED FIRE EXTINGUISHER CABINET WITH 10LBS ABC FIRE EXTINGUISHER.

28 HALF HEIGHT 6" CMU WALL AT 4'-0" HIGH.

No. Revisions: Date:

BID DOCUMENTS 01/13/2023

1 BULLETIN 01 07/12/2024

6 3'-0" X 4'-0" EMERGENCY MANAGEMENT CART (VV).

7 5'-4" X 2'-4" FREE STANDING RACK (VV).

8 24" DEEP STAINLESS STEEL WORK SURFACE.

9 CLEARANCE SPACE FOR (2) PALLETS (VV).

10 WALL MOUNTED PHONE - TOP AT 48" AFF.

12 CARD READER AUTO-OPERATOR

13 TOUCHLESS AUTO-OPERATOR

14 EXISTING COOLER / FREEZER CONDENSER UNITS TO REMAIN.

15 SOAP DISPENSER (VC).

16 WALL MOUNTED LAVATORY

17 PAPER TOWEL DISPENSER (VC).

18 INFILL EXISTING OPENING AT THE CONCLUSION OF PHASE

19 12" DEEP ADJUSTABLE STAINLESS STEEL SHELVES ON BRACKETS AND VERTICAL STANDARDS . INSTALL

SEE MECHANICAL DRAWINGS.

BY OHERS

EDITED FOR EQUIPMENT PROCUREMENT 10/7/2024

D R A W I N G N O T E S - FOR WORK PROVIDED BY

OTHERS

25 NEW WALK-IN FREEZER WITH INSULATED PANEL FLOOR AND RAMP - CLEARANCES PER MANUFACTURER -

26 NEW WALK-IN COOLER WITH INSULATED PANEL FLOOR AND RAMP - CLEARANCES PER MANUFACTURER -

SEE MECHANICAL DRAWINGS.

Sheets
1-AE115 - PHASE B1 NEW WORK PLAN

File details come from the government source that posted it. Updated .