This document contains a justification and approval for other than full and open competition for a federal contract opportunity. The Department of Veterans Affairs Cincinnati VAMC intends to release an invitation for bid for project number 539-20-211 entitled Correct FCA Deficiencies FTD Interior Deficiencies on or about August 10, 2020. The project will be posted on beta.sam.gov and involves improving exhaust systems at the Cincinnati VAMC. The contract value is between $500,000 and $1,000,000 and has a NAICS code of 238220 with a small business size standard of $16.5 million. The solicitation will be set aside as a 100% small business opportunity with an SDVOSB preference. Offerors must be registered in the Vendor Information Pages and SAM databases and have no more than three serious or one repeat or willful OSHA or EPA violations in the past three years, along with an EMR of 1.0 or less. The duration shall not exceed 180 days from notice to proceed and bonds will be required.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 539-18-101 ADDENDUM 3 WRITE UP.pdf | ||
| 36C25020B0068 0003.docx | DOCX document | |
| 539-18-101 Addendum 3 Dwgs.pdf | ||
| Addendum 2 Drawings Revisions are clouded.pdf | ||
| 36C25020B0068 0002.docx | DOCX document | |
| Location of temporary door storage.pdf | ||
| S04 Site Visit Sign in Sheet.pdf | ||
| 01 00 00 ADDENDUM 2.pdf | ||
| Revise Bid Schedule Statement of Bid Items.docx | DOCX document | |
| Addendum 2 Specifictions Revisons write up.pdf | ||
| 36C25020B0068 0001.docx | DOCX document | |
| 36C25020B0068.docx | DOCX document | |
| 539-18-101 CD Bid Specifications (8-21-2020).pdf | ||
| Wage Determination OH20200082.pdf | ||
| S02 RFI Form.docx | DOCX document | |
| 539-18-101 CD Bid Drawings (8-21-2020).pdf | ||
| S02 Contractor EMR Certification Form.docx | DOCX document |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Page 1 of
DEPARTMENT OF VETERANS AFFAIRS
Justification and Approval
For
Other Than Full and Open Competition
Acquisition Plan Action ID: VA250-20-AP-3967
1. Contracting Activity: Department of Veterans Affairs, Network Contracting Office (NCO) 10, 260 E. University Avenue, Cincinnati, OH 45219.
The Requesting Agency is VISN 10, VAMC Medical Center, Engineering Service (138), 3200 Vine Street, Cincinnati, OH 45220.
2. Nature and/or Description of the Action Being Processed:
Engineering Service is requesting approval to use other than full and open competition to solicit a Brand Name Only for the Corbin Russwin core cylinders, for use on Project No.
539-18-101, Improve Exhaust System. This project will be awarded as a new Firm- Fixed Price contract. This Justification and Approval (J&A) is submitted pursuant to the authority of 10 U.S.C 2304 (c) (1) or 41 U.S.C. 253 (c) (1), which provides that full and open competition need not be obtained where there is “only one responsible source and no other supplies or services will satisfy agency requirements.” Federal Acquisition Regulation (FAR) Part 6.302-1(c) “Only one responsible source and no other supplies or services will satisfy agency requirements.”
3. Description of Supplies/Services Required to Meet the Agency’s Needs:
The subject project will address various FCA gaps throughout building #1 at the main hospital by modifying various door hardware & seals and modifying the existing ventilation system to provide proper exhaust ventilation needed to suit room pressurization requirements. Each door will have installed a uncombinated removable core cylinder. Cylinders are removable with a special key or tool without disassembly of knob or lockset. Core meets the medical center policy for key locks. One grand master key is available to open all doors by authorized individuals. The Estimated Value of the Corwin Russwin Lock Sets is. The estimated value of the Improve Exhaust System project is.
4. Statutory Authority Permitting Other than Full and Open Competition:
(X) (1) Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements per FAR 6.302-1;
( ) (2) Unusual and Compelling Urgency per FAR 6.302-2;
( ) (3) Industrial Mobilization, Engineering, Developmental or Research Capability
Expert Services per FAR 6.302-3;
( ) (4) International Agreement per FAR 6.302-4 ( ) (5) Authorized or Required by Statute FAR 6.302-5;
( ) (6) National Security per FAR 6.302-6;
( ) (7) Public Interest per FAR 6.302-7;
Page 2 of
5. Demonstration that the Contractor’s Unique Qualifications or Nature of the Acquisition Requires the Use of the Authority Cited Above (applicability of authority):
To meet needs stated above the medical center currently utilizes a “Corbin-Russwin HO Keyway Great Grand Master Key System”, single master key system is essential to the Governments requirements, thereby precluding consideration of a product manufactured by another company. In addition, the core system is a requirement of VA engineering policy MP–3. As the Cincinnati VA medical center continues to move toward consolidation, patient and staff safety concerns remain at the forefront of design decisions when selecting systems. Accordingly, Corbin-Russwin is the only manufacture capable of providing the lock cylinders described in section 3 above without the Veteran’s Health Administration experiencing substantial duplication of cost that could not be expected to be recovered through competition. To change to a different locking system would require numerous master keys potentially causing delays in accessing all area of the campus in event of emergencies. The lock set requested allows the facility to expand and renovate as required and maintain the ability to meet patient and staff safety requirements.
6. Description of Efforts Made to ensure that offers are solicited from as many potential sources as deemed practicable:
The A/E Contractor Levin Porter Architects plans specifically mentions the continued use of Corbin Russwin Door Lock Sets. Efforts were not made to solicit from other lock lift manufacturers, because it is Levin Porter Architects expert opinion that utilizing other lock manufacturer’s locksets would decrease the consistency and reliability of the facility’s operations. This in turn would cause the patient care provided to our veterans to suffer. This solicitation will be publicized via Beta.SAM.gov. The approved Justification and Approval (J&A) for Corbin Russwin lock sets will be posted with the solicitation.
7. Determination by the Contracting Officer that the Anticipated Cost to the Government will be Fair and Reasonable:
Determination of fair and reasonableness of cost will be based upon a complete price analysis and Independent Government Cost Estimate. The anticipated cost will be considered fair and reasonable. This project will be issued as an Invitation for Bid (IFB).
Tradeoffs and Evaluation Factors are not applicable for this project. Furthermore, because Corbin Russwin is being purchased at prices consistent with their GSA contract, their prices have been determined to be fair and reasonable.
8. Description of the Market Research Conducted and the Results, or a Statement of the Reasons Market Research Was Not Conducted:
Market research has been previously conducted for prior projects, concerning this subject.
The master key system has been established here at the Cincinnati VAMC and the system for thousands of doors and needs to maintain this standardization in order to maintain efficiency and maintainability of the system.
Page 3 of
9. Any Other Facts Supporting the Use of Other than Full and Open Competition:
All door lock manufacturers have proprietary keyways on their lock cylinders, which by their very nature are designed to be operable only by a key of the same cut and shape.
Because the keyways are proprietary, only that manufacturer can create a key which will fit its own lock cylinder. The reason(s) for proprietary keyways is the very same reason door locks are needed – it’s one of security. Also for reasons of security, it is not desirable to have multiple lock manufacturers for multiple doors – not only is it inefficient to try and keep track of lock is manufactured by which manufacturer, it is also critical for the Police Service to have a master key at its disposal which can operate any lockset at the facility.
The presence of multiple manufactured keyways would not allow this critical need to happen. The Cincinnati VA Medical Center currently has locksets manufactured by Corbin Russwin and any/all additional locksets must match the Corbin Russwin keyway. The locksets manufactured by Corbin Russwin are a critical role in maintaining the security of the facility. In addition, the necessity of providing a lock set which has a cylinder that can be operated by the facility master key allows the VA locksmith shop to respond to all key request and maintenance issues quickly and efficiently. A single source manufacturer also allows for prompt technical support whenever problems are encountered.
10. Listing of Sources that Expressed, in Writing, an Interest in the Acquisition:
See Section VI above.
11. A Statement of the Actions, if any, the Agency May Take to Remove or Overcome any Barriers to Competition before Making subsequent acquisitions for the supplies or services required:
Solicitations for future requirements will utilize “brand name or equal” language, if it is in the Government’s best interest to do so. The current requirement must be solicited using a brand name description because the Government needs to create an exact copy of a system/item that is currently in use.
12. Requirements Certification: I certify the supporting data, including the statement of the
Government’s minimum needs and other rationale for other than full and open competition is complete and accurate to the best of my knowledge. (FAR Subpart 6.303-1(b))
Joshua Schneider Date Project Engineer, Engineering Service VAMC – Cincinnati, OH
Page 4 of
13. Approvals in accordance the VHAPM Part 806.3 OFOC SOP:
a. Contracting Officer's Certification (required): I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.
Ronald T. Heidemann Date Contracting Officer Network Contracting Office (NCO) 10 http://vaww.pclo.infoshare.va.gov/PMWeb/VHAPM_Part_806.3.aspx
| 2. Nature and/or Description of the Action Being Processed: |
| 3. Description of Supplies/Services Required to Meet the Agency’s Needs: |
| 4. Statutory Authority Permitting Other than Full and Open Competition: |
| 5. Demonstration that the Contractor’s Unique Qualifications or Nature of the Acquisition Requires the Use of the Authority Cited Above (applicability of authority): |
| 6. Description of Efforts Made to ensure that offers are solicited from as many potential sources as deemed practicable: |
| 7. Determination by the Contracting Officer that the Anticipated Cost to the Government will be Fair and Reasonable: |
| 8. Description of the Market Research Conducted and the Results, or a Statement of the Reasons Market Research Was Not Conducted: |
| 9. Any Other Facts Supporting the Use of Other than Full and Open Competition: |
| 10. Listing of Sources that Expressed, in Writing, an Interest in the Acquisition: |
| 11. A Statement of the Actions, if any, the Agency May Take to Remove or Overcome any Barriers to Competition before Making subsequent acquisitions for the supplies or services required: |
| 12. Requirements Certification: I certify the supporting data, including the statement of the Government’s minimum needs and other rationale for other than full and open competition is complete and accurate to the best of my knowledge. (FAR Subpart 6.... |
| 13. Approvals in accordance the VHAPM Part 806.3 OFOC SOP: |
| Joshua Schneider: | |
| Date: 09/24/2020 | |
| Ronald T Heidemann: | |
| Date_2: 09-24-2020 | |
| 2020-09-24T08:06:53-0400 | |
| Joshua S. Schneider 3481246 |
| 2020-09-24T08:11:46-0400 | |
| RONALD T. HEIDEMANN 119107 |
File details come from the government source that posted it. Updated .