36C25019B0044-007.pdf
PDF 4 MB Posted
- Solicitation number
- 36C25019B0044
About this file
36C25019B0044 Drawings - Vol 4.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25019C0265-000.docx | DOCX document | |
| 36C25019B0044-0003001.pdf | ||
| 36C25019B0044-0003000.docx | DOCX document | |
| 36C25019B0044-0002001.pdf | ||
| 36C25019B0044-0002002.pdf | ||
| 36C25019B0044-0002004.xlsx | XLSX spreadsheet | |
| 36C25019B0044-0002005.pdf | ||
| 36C25019B0044-0002000.docx | DOCX document | |
| 36C25019B0044-0002006.pdf | ||
| 36C25019B0044-0002003.pdf | ||
| 36C25019B0044-0001001.pdf | ||
| 36C25019B0044-0001000.docx | DOCX document | |
| 36C25019B0044-002.pdf | ||
| 36C25019B0044-008.pdf | ||
| 36C25019B0044-006.pdf | ||
| 36C25019B0044-004.pdf | ||
| 36C25019B0044-001.docx | DOCX document | |
| 36C25019B0044-005.pdf | ||
| 36C25019B0044-003.pdf | ||
| 36C25019B0044-000.docx | DOCX document | |
| 36C25019B0044-000.docx | DOCX document |
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Drawing Title
Approved: Service Chief Location
Building Number
Project Title
Checked Drawn
Date
Project No.
Drawing Number
Dwg. of on e-ei gh th i nc h o ne f oo t on e-qu ar te r in ch o ne f oo t th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne f oo t th re e-qu ar te rs i nc h on e in ch o ne f oo t on e an d on e-ha lf in ch es th re e in ch es o ne f oo t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
FULLY SUPPRESSED
Professional Seal
Approved: Project Manager
RENOVATE BUILDING 411
06/25/2019
CONTROLS AND AUTOMATION
411M701
PCWPCW
552-19-502
VA MEDICAL CENTER DAYTON, OHIO
B411
Revisions Date
Corridor C-G-2
Mechanical
28x28
411-AHU3
411-AHU4
30x30
24x36
411AFM9
40x22
30x30
26x26
30x3026x26
BOD:7' - 2"
40x22 x3
30x30
24x28
24x28
38x18
44x16
411AFM6
Drawing Title
Approved: Service Chief Location
Building Number
Project Title
Checked Drawn
Date
Project No.
Drawing Number
Dwg. of on e-ei gh th i nc h o ne f oo t on e-qu ar te r in ch o ne f oo t th re e-ei gh th s in ch on e-ha lf in ch o ne f oo t th re e-qu ar te rs i nc h on e in ch o ne f oo t on e an d on e-ha lf in ch es th re e in ch es o ne f oo t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
FULLY SUPPRESSED
Professional Seal
Approved: Project Manager
RENOVATE BUILDING 411
06/25/2019
LOWER LEVEL PLAN -
DUCTWORK
411MH100
PCWPCW
552-19-502
VA MEDICAL CENTER DAYTON, OHIO
B411
N Scale: 1/2" = 1'-0"
LOWER LEVEL PLAN - DUCTWORK
NOTES
1 EXISTING DUCTWORK TO REMAIN.
2 EXISTING AIR HANDLING UNIT TO REMAIN.
3 REWORK EXISTING SPRINKLER LINE BLOCKING ACCESS TO DUCT CONNECTION.
4 TRANSITION DUCTWORK TO FULL SIZE OF EQUIPMENT CONNECTION.
5 DUCT UP THRU FLOOR. REFER TO SHEET 411MH101 FOR CONTINUATION.
6 5" HIGH CONCRETE PAD.
7 RELOCATE 411-AHU4 SUPPLY FAN POWER FEED TO ALLOW DUCT CONNECTION.
8 UTILIZE PANELS IN THIS AREA (411-2-3B, 411-2-3B-D AND 411E-3-1-5A) FOR SOURCES TO
ELECTRICAL ITEMS ASSOCIATED WITH THE INSTALLATION OF 411-AHU3 INCLUDING: 411-
SF3, 411-RF3, 411-HWCP3, 120V CONNECTOIN TO AHU LIGHTS/RECPRACLES, ETC.
PROVIDE MAGNETIC MOTOR STARTER FOR 411-HWCP3 AND VFDS FOR 411-SF3 AND 411-
RF3. PROVIDE ALL WIRING, CONDUIT, DISCONNECT MEANS, CIRCUIT BREAKERS AS
REQUIRED.
GENERAL NOTES
A REFER TO SHEET 411M001 FOR LEGEND, ABBREVIATIONS AND ADDITIONAL GENERAL
NOTES.
Vestibule
Vestibule
126A
Women's Locker Room
Office
CLASSROOM
Men's Locker Room 116A
Corridor C-1-6
Staff Comp.
4-5
6ø
CD1
4-2
4-6
D
8ø
CD1
8ø
CD1
6ø
CD1
10ø
CD1
10ø
CD1
6ø
CD1
x1
16x12
36x20
8x
12x12
12x10
14x8
411HWFT1
411HWFT1
411HWFT1
411HWFT1
411HWPR2
411-CUH1
4-9
4-6
24x12
CG1
24x24
CG1
Kitchen Staff Break Room
R
24x12
CG1
Vestibule 118A
HAC
Tech. Closet
8ø
CD1
8ø
CD1
R
28x14
TR2
18x12
TR2
x2
20x18
24x12
CG114x8
TR1
4-20
4-20
4-3
36x36
411VRF1
R 66"x31"
411VRFHD1
24x12
CR3
411EF5
411-EF4
R
8ø
CD3
10x8
8ø
CD3
x8
12ø
CD3
12ø
CD3
6ø
12ø
CD3
14x8 14x8 x1
D
D
8ø
CORRIDOR
Elec. Cl.
Mech.
Women's Restroom 126B
Corridor C-1-5
Men's Restroom 116B
CONSULT ROOM
OFFICE
RECEPTION
TOILET ROOM
122 ELECT.
ENTRY
30x30 x1 ø
28x20
22x1218x1216x12
6ø
CD1
x1
18x12
14x12
10x12
10x8 8x8
6ø
28x20
26x18 x1
22x10 x2
10ø
CD1
10ø
CD3
10ø
CD3
10ø
CD3
10ø
CD1
10ø
CD1
10ø
CD1
12ø
CD3
24x12
CG1
3-4
3-1
3-2
3-3
24x24
CG1
24x24
CG1
x1
8x
22x10
24x12
CG124x12
CG1
18x10
8ø
CD1
8ø
CD1
6ø
CD1
6ø
CD1
6ø
CD1
6ø
CD1
24x12
CG1
36x20
411AFM4
411AFM5
6 6
3 8
3 8
3 8
SP
SP
Drawing Title
Approved: Service Chief Location
Building Number
Project Title
Checked Drawn
Date
Project No.
Drawing Number
Dwg. of on e-ei gh th i nc h o ne f oo t on e-qu ar te r in ch o ne f oo t th re e-ei gh th s in ch on e-ha lf in ch o ne f oo t th re e-qu ar te rs i nc h on e in ch o ne f oo t on e an d on e-ha lf in ch es th re e in ch es o ne f oo t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
FULLY SUPPRESSED
Professional Seal
Approved: Project Manager
RENOVATE BUILDING 411
06/25/2019
FIRST FLOOR PLAN - DUCTWORK
411MH101
PCWPCW
552-19-502
VA MEDICAL CENTER DAYTON, OHIO
B411
N Scale: 1/4" = 1'-0"
FIRST FLOOR PLAN - DUCTWORK
NOTES
1 EXISTING DUCTWORK TO REMAIN.
2 EXISTING EXHAUST FAN TO REMAIN.
3 EXISTING HEATING HOT WATER RADIATOR TO REMAIN.
4 EXISTING INDOOR FAN COIL UNIT TO REMAIN.
5 EXISTING CONDENSING UNIT TO REMAIN.
6 EXISTING AIR DEVICE TO REMAIN.
7 DUCT THRU FLOOR WITH TYPE 'B' STATIC FIRE DAMPER. ACCESS FROM THIS FLOOR.
REFER TO SHEET 411MH100 FOR CONTINUATION.
8 INTEGRATE CONTROL OF HOT WATER RADIATOR INTO THE ASSOCIATED AIR TERMINAL
UNIT CONTROL. REFER TO CONTROL DIAGRAM/SEQUENCE ON SHEET 411M701 FOR
ADDITIONAL INFORMATION.
9 DUCT UP TO EXHAUST FAN ABOVE. TRANSITION DUCT TO FULL SIZE OF EQUIPMENT
CONNECTION. REUSE EXISTING ROOF PENETRATION.
10 CAP DUCT FOR FURURE EXTENSION. SEAL AIR TIGHT.
11 PROVIDE DUCT STATIC PRESSURE SENSOR (2 TOTAL) FOR CONTROL OF 411-SF3.
GENERAL NOTES
A REFER TO SHEET 411M001 FOR LEGEND, ABBREVIATIONS AND ADDITIONAL GENERAL
NOTES.
| Sheet - 411M701 - CONTROLS AND AUTOMATION |
| Sheets |
| 411M001 - LEGEND, INDEX AND GENERAL NOTES |
| 411M501 - DETAILS |
| 411M502 - DETAILS |
| 411M601 - SCHEDULES |
| 411M701 - CONTROLS AND AUTOMATION |
| 411MH100 - LOWER LEVEL PLAN - DUCTWORK |
| 411MH101 - FIRST FLOOR PLAN - DUCTWORK |
| 411MP100 - LOWER LEVEL PLAN - PIPING |
| 411MP101 - FIRST FLOOR PLAN - PIPING |
| Sheet - 411MH100 - LOWER LEVEL PLAN - DUCTWORK |
| Sheets |
| 411M001 - LEGEND, INDEX AND GENERAL NOTES |
| 411M501 - DETAILS |
| 411M502 - DETAILS |
| 411M601 - SCHEDULES |
| 411M701 - CONTROLS AND AUTOMATION |
| 411MH100 - LOWER LEVEL PLAN - DUCTWORK |
| 411MH101 - FIRST FLOOR PLAN - DUCTWORK |
| 411MP100 - LOWER LEVEL PLAN - PIPING |
| 411MP101 - FIRST FLOOR PLAN - PIPING |
| Sheet - 411MH101 - FIRST FLOOR PLAN - DUCTWORK |
| Sheets |
| 411M001 - LEGEND, INDEX AND GENERAL NOTES |
| 411M501 - DETAILS |
| 411M502 - DETAILS |
| 411M601 - SCHEDULES |
| 411M701 - CONTROLS AND AUTOMATION |
| 411MH100 - LOWER LEVEL PLAN - DUCTWORK |
| 411MH101 - FIRST FLOOR PLAN - DUCTWORK |
| 411MP100 - LOWER LEVEL PLAN - PIPING |
| 411MP101 - FIRST FLOOR PLAN - PIPING |
File details come from the government source that posted it.