36C25019B0044-007.pdf

PDF 4 MB Posted

Attached to
552-19-203: Building 411 Renovation (VA-19-00068610)
Solicitation number
36C25019B0044
Issued by

About this file

36C25019B0044 Drawings - Vol 4.pdf

View the file

Other files

File Type Posted
36C25019C0265-000.docx DOCX document
36C25019B0044-0003001.pdf PDF
36C25019B0044-0003000.docx DOCX document
36C25019B0044-0002001.pdf PDF
36C25019B0044-0002002.pdf PDF
36C25019B0044-0002004.xlsx XLSX spreadsheet
36C25019B0044-0002005.pdf PDF
36C25019B0044-0002000.docx DOCX document
36C25019B0044-0002006.pdf PDF
36C25019B0044-0002003.pdf PDF
36C25019B0044-0001001.pdf PDF
36C25019B0044-0001000.docx DOCX document
36C25019B0044-002.pdf PDF
36C25019B0044-008.pdf PDF
36C25019B0044-006.pdf PDF
36C25019B0044-004.pdf PDF
36C25019B0044-001.docx DOCX document
36C25019B0044-005.pdf PDF
36C25019B0044-003.pdf PDF
36C25019B0044-000.docx DOCX document
36C25019B0044-000.docx DOCX document
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Drawing Title

Approved: Service Chief Location

Building Number

Project Title

Checked Drawn

Date

Project No.

Drawing Number

Dwg. of on e-ei gh th i nc h o ne f oo t on e-qu ar te r in ch o ne f oo t th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne f oo t th re e-qu ar te rs i nc h on e in ch o ne f oo t on e an d on e-ha lf in ch es th re e in ch es o ne f oo t

F E

D C

B A

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

F E

D C

B A

FULLY SUPPRESSED

Professional Seal

Approved: Project Manager

RENOVATE BUILDING 411

06/25/2019

CONTROLS AND AUTOMATION

411M701

PCWPCW

552-19-502

VA MEDICAL CENTER DAYTON, OHIO

B411

Revisions Date

Corridor C-G-2

Mechanical

28x28

411-AHU3

411-AHU4

30x30

24x36

411AFM9

40x22

30x30

26x26

30x3026x26

BOD:7' - 2"

40x22 x3

30x30

24x28

24x28

38x18

44x16

411AFM6

Drawing Title

Approved: Service Chief Location

Building Number

Project Title

Checked Drawn

Date

Project No.

Drawing Number

Dwg. of on e-ei gh th i nc h o ne f oo t on e-qu ar te r in ch o ne f oo t th re e-ei gh th s in ch on e-ha lf in ch o ne f oo t th re e-qu ar te rs i nc h on e in ch o ne f oo t on e an d on e-ha lf in ch es th re e in ch es o ne f oo t

F E

D C

B A

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

F E

D C

B A

FULLY SUPPRESSED

Professional Seal

Approved: Project Manager

RENOVATE BUILDING 411

06/25/2019

LOWER LEVEL PLAN -

DUCTWORK

411MH100

PCWPCW

552-19-502

VA MEDICAL CENTER DAYTON, OHIO

B411

N Scale: 1/2" = 1'-0"

LOWER LEVEL PLAN - DUCTWORK

NOTES

1 EXISTING DUCTWORK TO REMAIN.

2 EXISTING AIR HANDLING UNIT TO REMAIN.

3 REWORK EXISTING SPRINKLER LINE BLOCKING ACCESS TO DUCT CONNECTION.

4 TRANSITION DUCTWORK TO FULL SIZE OF EQUIPMENT CONNECTION.

5 DUCT UP THRU FLOOR. REFER TO SHEET 411MH101 FOR CONTINUATION.

6 5" HIGH CONCRETE PAD.

7 RELOCATE 411-AHU4 SUPPLY FAN POWER FEED TO ALLOW DUCT CONNECTION.

8 UTILIZE PANELS IN THIS AREA (411-2-3B, 411-2-3B-D AND 411E-3-1-5A) FOR SOURCES TO

ELECTRICAL ITEMS ASSOCIATED WITH THE INSTALLATION OF 411-AHU3 INCLUDING: 411-

SF3, 411-RF3, 411-HWCP3, 120V CONNECTOIN TO AHU LIGHTS/RECPRACLES, ETC.

PROVIDE MAGNETIC MOTOR STARTER FOR 411-HWCP3 AND VFDS FOR 411-SF3 AND 411-

RF3. PROVIDE ALL WIRING, CONDUIT, DISCONNECT MEANS, CIRCUIT BREAKERS AS

REQUIRED.

GENERAL NOTES

A REFER TO SHEET 411M001 FOR LEGEND, ABBREVIATIONS AND ADDITIONAL GENERAL

NOTES.

Vestibule

Vestibule

126A

Women's Locker Room

Office

CLASSROOM

Men's Locker Room 116A

Corridor C-1-6

Staff Comp.

4-5

6ø

CD1

4-2

4-6

D

8ø

CD1

8ø

CD1

6ø

CD1

10ø

CD1

10ø

CD1

6ø

CD1

x1

16x12

36x20

8x

12x12

12x10

14x8

411HWFT1

411HWFT1

411HWFT1

411HWFT1

411HWPR2

411-CUH1

4-9

4-6

24x12

CG1

24x24

CG1

Kitchen Staff Break Room

R

24x12

CG1

Vestibule 118A

HAC

Tech. Closet

8ø

CD1

8ø

CD1

R

28x14

TR2

18x12

TR2

x2

20x18

24x12

CG114x8

TR1

4-20

4-20

4-3

36x36

411VRF1

R 66"x31"

411VRFHD1

24x12

CR3

411EF5

411-EF4

R

8ø

CD3

10x8

8ø

CD3

x8

12ø

CD3

12ø

CD3

6ø

12ø

CD3

14x8 14x8 x1

D

D

8ø

CORRIDOR

Elec. Cl.

Mech.

Women's Restroom 126B

Corridor C-1-5

Men's Restroom 116B

CONSULT ROOM

OFFICE

RECEPTION

TOILET ROOM

122 ELECT.

ENTRY

30x30 x1 ø

28x20

22x1218x1216x12

6ø

CD1

x1

18x12

14x12

10x12

10x8 8x8

6ø

28x20

26x18 x1

22x10 x2

10ø

CD1

10ø

CD3

10ø

CD3

10ø

CD3

10ø

CD1

10ø

CD1

10ø

CD1

12ø

CD3

24x12

CG1

3-4

3-1

3-2

3-3

24x24

CG1

24x24

CG1

x1

8x

22x10

24x12

CG124x12

CG1

18x10

8ø

CD1

8ø

CD1

6ø

CD1

6ø

CD1

6ø

CD1

6ø

CD1

24x12

CG1

36x20

411AFM4

411AFM5

6 6

3 8

3 8

3 8

SP

SP

Drawing Title

Approved: Service Chief Location

Building Number

Project Title

Checked Drawn

Date

Project No.

Drawing Number

Dwg. of on e-ei gh th i nc h o ne f oo t on e-qu ar te r in ch o ne f oo t th re e-ei gh th s in ch on e-ha lf in ch o ne f oo t th re e-qu ar te rs i nc h on e in ch o ne f oo t on e an d on e-ha lf in ch es th re e in ch es o ne f oo t

F E

D C

B A

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

F E

D C

B A

FULLY SUPPRESSED

Professional Seal

Approved: Project Manager

RENOVATE BUILDING 411

06/25/2019

FIRST FLOOR PLAN - DUCTWORK

411MH101

PCWPCW

552-19-502

VA MEDICAL CENTER DAYTON, OHIO

B411

N Scale: 1/4" = 1'-0"

FIRST FLOOR PLAN - DUCTWORK

NOTES

1 EXISTING DUCTWORK TO REMAIN.

2 EXISTING EXHAUST FAN TO REMAIN.

3 EXISTING HEATING HOT WATER RADIATOR TO REMAIN.

4 EXISTING INDOOR FAN COIL UNIT TO REMAIN.

5 EXISTING CONDENSING UNIT TO REMAIN.

6 EXISTING AIR DEVICE TO REMAIN.

7 DUCT THRU FLOOR WITH TYPE 'B' STATIC FIRE DAMPER. ACCESS FROM THIS FLOOR.

REFER TO SHEET 411MH100 FOR CONTINUATION.

8 INTEGRATE CONTROL OF HOT WATER RADIATOR INTO THE ASSOCIATED AIR TERMINAL

UNIT CONTROL. REFER TO CONTROL DIAGRAM/SEQUENCE ON SHEET 411M701 FOR

ADDITIONAL INFORMATION.

9 DUCT UP TO EXHAUST FAN ABOVE. TRANSITION DUCT TO FULL SIZE OF EQUIPMENT

CONNECTION. REUSE EXISTING ROOF PENETRATION.

10 CAP DUCT FOR FURURE EXTENSION. SEAL AIR TIGHT.

11 PROVIDE DUCT STATIC PRESSURE SENSOR (2 TOTAL) FOR CONTROL OF 411-SF3.

GENERAL NOTES

A REFER TO SHEET 411M001 FOR LEGEND, ABBREVIATIONS AND ADDITIONAL GENERAL

NOTES.

Sheet - 411M701 - CONTROLS AND AUTOMATION
Sheets
411M001 - LEGEND, INDEX AND GENERAL NOTES
411M501 - DETAILS
411M502 - DETAILS
411M601 - SCHEDULES
411M701 - CONTROLS AND AUTOMATION
411MH100 - LOWER LEVEL PLAN - DUCTWORK
411MH101 - FIRST FLOOR PLAN - DUCTWORK
411MP100 - LOWER LEVEL PLAN - PIPING
411MP101 - FIRST FLOOR PLAN - PIPING
Sheet - 411MH100 - LOWER LEVEL PLAN - DUCTWORK
Sheets
411M001 - LEGEND, INDEX AND GENERAL NOTES
411M501 - DETAILS
411M502 - DETAILS
411M601 - SCHEDULES
411M701 - CONTROLS AND AUTOMATION
411MH100 - LOWER LEVEL PLAN - DUCTWORK
411MH101 - FIRST FLOOR PLAN - DUCTWORK
411MP100 - LOWER LEVEL PLAN - PIPING
411MP101 - FIRST FLOOR PLAN - PIPING
Sheet - 411MH101 - FIRST FLOOR PLAN - DUCTWORK
Sheets
411M001 - LEGEND, INDEX AND GENERAL NOTES
411M501 - DETAILS
411M502 - DETAILS
411M601 - SCHEDULES
411M701 - CONTROLS AND AUTOMATION
411MH100 - LOWER LEVEL PLAN - DUCTWORK
411MH101 - FIRST FLOOR PLAN - DUCTWORK
411MP100 - LOWER LEVEL PLAN - PIPING
411MP101 - FIRST FLOOR PLAN - PIPING

File details come from the government source that posted it.