36C25019B0044-0003001.pdf
PDF 690 KB Posted
- Solicitation number
- 36C25019B0044
About this file
36C25019B0044 0003 Sheet - 411MH100 - LOWER LEVEL PLAN - DUCTWORK.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25019C0265-000.docx | DOCX document | |
| 36C25019B0044-0003000.docx | DOCX document | |
| 36C25019B0044-0002001.pdf | ||
| 36C25019B0044-0002002.pdf | ||
| 36C25019B0044-0002004.xlsx | XLSX spreadsheet | |
| 36C25019B0044-0002005.pdf | ||
| 36C25019B0044-0002000.docx | DOCX document | |
| 36C25019B0044-0002006.pdf | ||
| 36C25019B0044-0002003.pdf | ||
| 36C25019B0044-0001001.pdf | ||
| 36C25019B0044-0001000.docx | DOCX document | |
| 36C25019B0044-002.pdf | ||
| 36C25019B0044-008.pdf | ||
| 36C25019B0044-007.pdf | ||
| 36C25019B0044-006.pdf | ||
| 36C25019B0044-004.pdf | ||
| 36C25019B0044-001.docx | DOCX document | |
| 36C25019B0044-005.pdf | ||
| 36C25019B0044-003.pdf | ||
| 36C25019B0044-000.docx | DOCX document | |
| 36C25019B0044-000.docx | DOCX document |
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Corridor C-G-2
Mechanical
28x28
411-AHU3
411-AHU4
30x30
24x36
411AFM9
40x22
30x30
26x26
26x26
BOD:7' - 2"
40x22 x3
30x30
24x28
24x28
38x18
44x16
411AFM6
36x24
30x30
411-AHU4
Drawing Title
Approved: Service Chief Location
Building Number
Project Title
Checked Drawn
Date
Project No.
Drawing Number
Dwg. of on e-ei gh th i nc h o ne f oo t on e-qu ar te r in ch o ne f oo t th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne f oo t th re e-qu ar te rs i nc h on e in ch o ne f oo t on e an d on e-ha lf in ch es th re e in ch es o ne f oo t
F E
D C
B A
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
F E
D C
B A
FULLY SUPPRESSED
Professional Seal
Approved: Project Manager
RENOVATE BUILDING 411
06/25/2019
LOWER LEVEL PLAN -
DUCTWORK
411MH100
PCWPCW
552-19-502
VA MEDICAL CENTER DAYTON, OHIO
B411
N Scale: 1/2" = 1'-0"
LOWER LEVEL PLAN - DUCTWORK
NOTES
1 EXISTING DUCTWORK TO REMAIN.
2 EXISTING AIR HANDLING UNIT TO REMAIN.
3 REWORK EXISTING SPRINKLER LINE BLOCKING ACCESS TO DUCT CONNECTION.
4 TRANSITION DUCTWORK TO FULL SIZE OF EQUIPMENT CONNECTION.
5 DUCT UP THRU FLOOR. REFER TO SHEET 411MH101 FOR CONTINUATION.
6 5" HIGH CONCRETE PAD.
7 RELOCATE 411-AHU4 SUPPLY FAN POWER FEED TO ALLOW DUCT CONNECTION.
8 UTILIZE PANELS IN THIS AREA (411-2-3B, 411-2-3B-D AND 411E-3-1-5A) FOR SOURCES TO
ELECTRICAL ITEMS ASSOCIATED WITH THE INSTALLATION OF 411-AHU3 INCLUDING: 411-
SF3, 411-RF3, 411-HWCP3, 120V CONNECTOIN TO AHU LIGHTS/RECPRACLES, ETC.
PROVIDE MAGNETIC MOTOR STARTER FOR 411-HWCP3 AND VFDS FOR 411-SF3 AND 411-
RF3. PROVIDE ALL WIRING, CONDUIT, DISCONNECT MEANS, CIRCUIT BREAKERS AS
REQUIRED.
9 PROVIDE PLENUM BOX ON TOP OF AHU4 SUPPLY AIR OUTLET APPROXIMATELY 24" TALL.
10 CONNECT SUPPLY DUCT INTO SIDE OF NEW PLENUM BOX.
11 REMOVE DUCTWORK CONNECTIONS FOR 411-AHU4 AS INDICATED.
GENERAL NOTES
A REFER TO SHEET 411M001 FOR LEGEND, ABBREVIATIONS AND ADDITIONAL GENERAL
NOTES.
Revisions Date
1 ADDENDUM #1 08/09/2019
SCALE: 1/2" = 1'-0"
LOWER LEVEL PLAN - REMOVALS2
| Sheets |
| 411MH100 - LOWER LEVEL PLAN - DUCTWORK |
File details come from the government source that posted it.