This document provides details on a federal contract opportunity to renovate Building 1 at a Veterans Affairs medical center. The solicitation number is 36C24823R0199 and is being issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8. It seeks to convert five floors of the building from general medical/surgical beds to private patient rooms as part of Project 673-21-148. Interested parties should respond with pricing and qualification information by the specified due date to be considered for the award, which is expected to be granted in the following fiscal year for the renovation work. Key requirements include converting existing bed space and support areas to modernized private inpatient rooms while maintaining compliance with VA design guidelines.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos AHERA Survey Report
Performed at:
Building 1
James A. Haley VA Medical Center 13000 Bruce B. Downs Blvd
Tampa, FL 33612
Report Prepared For:
Biosphere International 13139 W. Linebaugh Ave
Tampa, Florida 33626
Report Prepared By:
OHC Environmental Engineering, Inc.
101 South Hoover Blvd., Suite 101 Tampa, Florida 33609
OHC Project #170161-AS
May 28, 2018
James A. Haley VA Medical Center Asbestos AHERA Survey
OHC Project No. 170161-AS i
May 28, 2017
Ronnie King Biosphere International 13139 W. Linebaugh Ave., Tampa, FL 33626
Re: Asbestos AHERA Survey
James A. Haley VA Medical Center 13000 Bruce B. Downs Blvd., Dear Mr. King, OHC Environmental Engineering, Inc. (OHC) is pleased to present the report for the Asbestos NESHAP Survey performed from November 27, 2017 to April 9, 2018. These services were conducted in Building 1 at the James A. Haley VA Medical Center located at 13000 Bruce B.
Downs Boulevard in Tampa, Florida.
If we can be of further assistance or if you should have any questions, please do not hesitate to contact us at your convenience.
Sincerely, Report Prepared by:
Kirill Smirnov Industrial Hygienist
Report Reviewed by:
Cristina Jones Project Manager
James A. Haley VA Medical Center ii
ASBESTOS NESHAP SURVEY
OHC PROJECT NO. 170161-AS
CLIENT NAME: Biosphere International
PROJECT NAME: JAHVA Building 1
PROJECT ADDRESS: James A. Haley VA Medical Center 13000 Bruce B. Downs Blvd., DATE OF SURVEY: November 2017-April 2018
CONSULTING FIRM: OHC Environmental Engineering, Inc.
101 South Hoover Blvd., Suite 101 Tampa, Florida 33609
SURVEYOR: Kirill Sminov
OHC PROJECT MANAGER: Cristina Jones
FLAC:
James F. Rizk
FLAC #ZA0000060
James A. Haley VA Medical Center iii
TABLE OF CONTENTS
1.0 INTRODUCTION
2.0 SCOPE OF WORK
3.0 EXECUTIVE SUMMARY
4.0 ASBESTOS SURVEY
4.1 Asbestos Survey Results
4.2 Asbestos Sampling Methods
4.3 Regulatory Requirements
4.4 Statutory Requirements
5.0 OBSERVATIONS
6.0 LIMITATIONS
7.0 DOCUMENT CONTENT
APPENDIX A: Photographs – Basement, Floors 3-7, and Penthouse
APPENDIX B: Photographs – Ground, First & Second Floors
APPENDIX C: Sampling Locations
APPENDIX D: Analytical Results – Basement, Floors 3-7, and Penthouse
APPENDIX E: Analytical Results – Ground, First & Second Floors
APPENDIX F: Consultant & Laboratory Credentials
James A. Haley VA Medical Center
1.0 INTRODUCTION
OHC Environmental Engineering, Inc., (OHC), was contracted by Ronnie King of Biosphere International to perform an Asbestos Survey in compliance with the National Emission Standard for Hazardous Air Pollutants (NESHAP) regulation for asbestos (40 CFR 61 Subpart M). The survey was performed throughout Building 1 at the James A.
Haley VA Medical Center in Tampa, Florida. A representative from OHC, Mr. Kirill Smirnov, visited the area from November 27th of 2017 to April 9th of 2018, to perform these services. This survey is limited to the identification and collection of Asbestos Containing Material (ACM) throughout all levels of Building 1 only.
2.0 SCOPE OF WORK
The scope of work for this survey included the following:
• A site visit and thorough NESHAP inspection by an Asbestos Hazard Emergency Response Act (AHERA) accredited asbestos building inspector working under the supervision of a Florida Licensed Asbestos Consultant (LAC) to identify suspect Asbestos Containing Material (ACM)
• Sampling, labeling and analyzing of accessible suspect ACM to be disturbed
• Preparation of a comprehensive report documenting the location and content of all materials sampled and analyzed, which includes suspect ACM and the category and assessment of identified hazardous materials
3.0 EXECUTIVE SUMMARY
Based on the results of the Polarized Light Microscopy (PLM), Asbestos Containing Materials (ACM) does exist within the scope of this survey, as indicated in Tables 1 and 2 below.
James A. Haley VA Medical Center
TABLE 1: ASBESTOS SURVEY RESULTS
BASEMENT, FLOORS 3-7, AND PENTHOUSE
JAMES A. HALEY VAMC – BUILDING 1
HSA Sample
ID
Sample Location
Material Description
Approx.
Quantity Result Category
10A Penthouse
White wrap on pipes and insulation 500 LF 15% Chrysotile – mastic
NF-II
(TSI) 10B Penthouse
10C Penthouse
40A Basement
Brown baseboard with tan mastic 300 LF 2% Chrysotile – texture
NF-II
(Misc) 40B Basement
40C Basement
76A
9x9 cream floor tile with olive streaks and black mastic. By
Elevator 3 left corner.
9x9 cream floor tile with olive streaks and black mastic
50,000 SF
3% Chrysotile – tile
8% Chrysotile – mastic
NF-I
(Misc)
76B In 7B-721B 76C By 7B-728 76D 5th floor lobby 76E 3rd floor lobby
80A 7B-721B Red 9x9 tile with black mastic in front of fire apparatus closets
1,000 SF
NF-I
(Misc)
80B 7A-718B
80C 7B-721B
82A Inside 7B-721B
Drywall with joint compound 40,000 SF 2% Chrysotile – joint compound
NF-II
(Misc)
82B Inside
82C Location above ceiling tile.
82D In 6B-624
82E Above ceiling on
82F 5A-502A
82G Above ceiling on
82H Inside 4B-421
82I Above ceiling on 4th floor
82J Behind chair left of 3B-305, inside damaged wall.
82K Above ceiling on 3rd
James A. Haley VA Medical Center
83A
Across from employee restroom by nurses station, next to water fountain
12x12 tile with gray-blue pattern and yellow mastic
20,000 SF
<1% Chrysotile −
Black/Yellow Mastic
OSHA Rules Apply
83B By stairwell door next to 7A-747B
83C By 7A-736 entrance to the right.
84A By South wing entrance on 7th floor
12x12 gray tile with gray and beige streaks and yellow and black mastics
15,000 SF 5% Chrysotile −
NF-I
(Misc)
84B By 7A-723 entrance.
84C Inside 7A-702A fire apparatus.
84D Across from 6A-
84E Left of 6A-648C.
By stairwell door.
85A 7A-722B
12x12 faded red tile in front of fire apparatus closet 1,000 SF 5% Chrysotile − mastic
NF-I
(Misc)
85B By 7A-702A 85C By 7A-702A 85D Inside 6A-648C 85E Inside 6A-625C
88A 7A-736
12x12 white tile with gray streaks 200 SF 4% Chrysotile − mastic
NF-I
(Misc) 88B 7A-736 88C 7A-736
89A By 7A-733
Gray fire proofing 30000 SF 4% Chrysotile RACM (Surfacing)
89B By 7A-733 89C By 7A-722D 89D By 7A-722D 89E By 7A-735
96A In front of elevators 10 and 11.
12x12 blue tile with black mastic 700 SF 6% Chrysotile − mastic
NF-I
(Misc) 96B In front of elevators 10 and 11.
96C In front of elevators 10 and 11.
James A. Haley VA Medical Center
96D Behind chairs left of elevator 10 on 3rd floor
96E Behind chairs right of elevator 11 on 3rd floor
97A Outside of doorway 7B- 705C
12x12 tan floor tile with white and beige streaks. Black/yellow mastic.
60,000 SF 8% Chrysotile − mastic
NF-I
(Misc)
97B In 7B-705. Left side by cubicles.
97C In 7B-705. 2ft from doorway.
97D
6th floor elevator 10 lobby, left corner by the chairs when facing elevators.
97E To the right of
6th floor elevator 11.
97F To the right of
5th floor elevator
97G Left of doorway 5B-539
99 99A Across from 7B- 704B
12x12 pink tile with brown streaks and yellow with black mastic
500 SF 3% Chrysotile – black mastic
NF-I
(Misc)
101A By 7B-725 Gold mastic on metal ductwork 3,000 SF 5% Chrysotile − mastic
NF-II
(Misc) 101B By elevator 3 on
5th floor 101C By 4A-459
114A
Left of the 6th floor elevator 5 if facing the doors 9x9 tan floor tile with white and brown streaks and black mastic
50,000 SF
15% Chrysotile –
NF-I
(Misc) 114B By 6B-625 door.
114C
Wall opposite 6A-634, corner before elevator lobby.
James A. Haley VA Medical Center
116A
Left of the 6th floor elevator 10 if facing the doors, by the corner. 12x12 tan floor tile with large beige and gray streaks.
Tan/black mastic
20,000 SF 7% Chrysotile − mastic
NF-I
(Misc) 116B By 6B-603 doorway.
116C Inside 6B-624
116D Left of Elevator 10 on 4th floor
116E Inside 4B-421
120A By 6A-625C 12x12 white tile with gray speckles and black mastic
10,000 SF 4% Chrysotile –
NF-I
(Misc) 120B
Across from 6A- 619, by clean linen closet.
120C By 6A-602A
125A Left of elevator 5 on 6th floor. Brown fire proofing in the middle of 6th floor
2,000 SF 7% Chrysotile RACM (Surfacing) 125B Left of elevator 5 on 6th floor.
125C By elevator 3 on 6th floor.
144A 4B-415
Black mastic on fire closet pipes 400 SF 2% Chrysotile – mastic
NF-II
(Misc)
144B 7A-718B 144C 6th fire closet 144D 5th fire closet 144E 3A-348C
147A Left of elevator 5, on 3rd floor 9x9 tan floor tile with brown streaks and black mastic
30,000 SF
10% Chrysotile –
NF-I
(Misc) 147B By 3B-301
147C In 3B-312B
150A 3rd floor
Gray tile with dark yellow mastic 250 SF 3% Chrysotile − mastic
NF-I
(Misc)
150B 3rd floor
150C 3rd floor
James A. Haley VA Medical Center
TABLE 2: ASBESTOS SURVEY RESULTS
GROUND, FIRST AND SECOND FLOORS
JAMES A. HALEY VAMC – BUILDING 1
HSA Sample
ID
Sample Location
Material Description
Approx.
Quantity Result Category
2A Inside 2D-217A
9x9 tile with brown streak and black mastic
50,000 SF
4% Chrysotile −
10% Chrysotile −
NF-I
(Misc)
2B Left of elevator 3 on 2nd floor
2C By 2D-255C, left of exit sign
2D 1B-156B, behind right double door
2E 1C-101B fire closet
3A Inside 2D-217A
Drywall with joint compound 45,000 SF 2% Chrysotile – joint compound
NF-II
(Misc)
3B Inside 2A-239 3C Inside 2B-207C
3D Above ceiling on 1st
3E Above ceiling on 1st
3F Above ceiling on ground floor
3G Above ceiling on ground floor
4A Inside 2D-217A
Red 9x9 tile with black mastic 1,000 SF
8% Chrysotile -
NF-I
(Misc)
4B Inside 2A-213B 4C Inside 2B-203B
4D In 1D-158 fire closet
4E In 1C-101B
6A Right of 2A- 215C
Dark tan vinyl tile with black accent tiles, two layers of tile underneath, and yellow and black mastic
400 SF 4% Chrysotile – black mastic
NF-I
(Misc) 6B In 2A-215 behind left wall
6C Right of stage, by exit door
8A By entrance to 2A-213B
9x9 tan tile with white streaks, black mastic
40,000 SF
4% Chrysotile –
5% Chrysotile –
NF-I
(Misc)
8B Left of 2A-221
8C Right of 2B- 201D
8D 1D-158 fire closet
8E Across from 1C- 101A
James A. Haley VA Medical Center
9A In 2B-203B 9x9 cream tile with olive streaks and black mastic
40,000 SF
2% Chrysotile –
NF-I
(Misc) 9B
By 2C-213, behind double door 9C In 2C-260A
10A Across from 2B-
9x9 black tile with white streaks and black mastic
1,500 SF
6% Chrysotile –
NF-I
(Misc)
10B Behind left hemodialysis door
10C Behind left ambulatory door
10D Right double door by 1C-102
10E Left double door by 1B-104
12A Right of elevator 11, behind chairs
12x12 white tile with beige splatters and yellow mastic 25,000 SF 2% Chrysotile – mastic
NF-I
(Misc)
12B Left of elevator
12C Right of 11, behind chairs
12D Ground floor by elevators
13A By elevator 10, 11 lobby, 2nd floor 12x12 blue tile with light blue speckles and black mastic
500 SF 3% Chrysotile – mastic
NF-I
(Misc) 13B
By vending machines, pharmacy pickup, 1st floor
13C By Elevator 3 on ground floor
15A By stair exit, next to 2A-228
12x12 cream tile with apricot streaks and yellow mastic
10,000 SF
NF-I
(Misc)
15B Inside GD-018A 15C Inside GD-010B
15D GA-024A
15E Inside GA-009A
18A Intersection by 2A-218
Gray fire proofing 80,000 SF 8% Chrysotile RACM (Surfacing)
18B By 2C-276D 18C By 2C-230 18D Cafeteria dining
18E Auditorium – by
TV
James A. Haley VA Medical Center
18F 1st floor by elevator lobby
18G 1st floor by elevator lobby
18H 1st floor
18I Ground floor by police entrance
18J Ground floor by walkway to garage
21A By 2C-222D Beige duct joint filling mastic 1,000 SF 6% Chrysotile – mastic
NF-II
(Misc) 21B Ground floor
22A IN 2C-222A
12x12 pink tile with black mastic 3,000 SF 15% Chrysotile – black mastic
NF-I
(Misc) 22B Left of 2c-222 entrance
22C By double doors next to ward entrance
23A By the exit to crosswalk 12x12 orange-tan tile with beige speckles and yellow mastic
500 SF 10% Chrysotile – black mastic
NF-I
(Misc) 23B By the exit-left side
23C By exit no smoking sign
27A By 2C-258
Gold mastic on ductwork 3,000 SF 4% Chrysotile – mastic
NF-II
(Misc)
27B By 2C-248 27C In 2D-204 27D 1st
32A In 2A-213B
Gray hard mastic on black pipe joints 500 SF 2% Chrysotile – mastic
NF-II
(Misc)
32B In 2D- 255A 32C In 2C-201B 32D 1st floor 32E Ground floor
33A 2C-222 by door
12x12 tan tile with beige and gray splatters, gray mastic 2,000 SF 6% Chrysotile – black mastic
NF-I
(Misc)
33B Right of TV, by chairs
33C Right of coffee machine
33D Dental waiting – behind chairs
33E By 1A-157 behind chairs
37 37A By entrance SICU hallway
12x12 blue tile with orange and blue streaks 4,000 SF 8% Chrysotile – black mastic
NF-I
(Misc)
James A. Haley VA Medical Center
38A By 2B-216
Silver wrap with pink insulation 5,000 LF 8% Chrysotile – wrap
NF-II
(TSI) 38B 1st floor
38C Ground floor
57A Chapel on 2nd floor, by entrance
White popcorn ceiling 400 SF 5% Chrysotile RACM
(Surfacing) 57B
Chapel on 2nd floor, by entrance
57C
Chapel on 2nd floor, by entrance
58A In 1B-109A 12x12 red tile on top of beige tile with yellow and black mastics
700 SF
NF-I
(Misc)
58B In 1B-122A
58C BY GA-024A
58D By GD-018A
59A In 1B-109A 12x12 White tile with gray and tan speckles, yellow mastic
5,000 SF
NF-I
(Misc)
59B In 1B-155A 59C Ground floor 59D Ground floor
62A In waiting lobby by windows 12x12 light pink tile with orange and blue speckles on beige tile with yellow and black mastic
400 SF
NF-I
(Misc) 62B In waiting lobby by windows
62C In waiting lobby by windows
63A Dental office suites – by entrance door 12x12 Gray tile with gray speckles. Yellow with dark beige mastic
200 SF 7% Chrysotile – black mastic
NF-I
(Misc) 63B
Dental office suites – by equipment cart
63C Dental office suites – by the hallway corner
69A ER lobby Green tile on top of beige tile. Yellow mastic.
500 SF
beige tile
7% Chrysotile –
NF-I
(Misc)
69B ER lobby
69C ER lobby
70 70A
In the basement, on the outside of ground floor pool
Brown pool mastic covering 1,500 SF 3% Chrysotile – mastic
NF-II
(Misc)
James A. Haley VA Medical Center
70B
In the basement, on the outside of ground floor pool
70C
In the basement, on the outside of ground floor pool
72A Safety office Gray vinyl panels on tile, yellow mastic 400 SF beige tile
7% Chrysotile –
NF-I
(Misc)
72B Safety office
72C Safety office
73A Ground floor Hard black-brown mastic inside fire closets on walls
300 SF 4% Chrysotile – mastic
NF-II
(Misc) 73B Ground floor
NF-I = Category I Non-friable ACM NF-II = Category II Non-Friable ACM RACM = Regulated Asbestos-Containing Materials
4.0 ASBESTOS SURVEY
The Environmental Protection Agency defines Asbestos Containing Material (ACM) as any material or product that contains more than one percent (1%) asbestos. Based on the observations and the laboratory analysis of the samples collected from the site, ACM does exist within the scope of this survey.
4.1 Asbestos Survey Results
Tables 3 and 4 below summarize the samples of suspect ACM collected. Note that samples in RED are considered asbestos-containing materials (ACM). Please refer to Appendix A of this report for photos of the materials sampled, Appendix B for asbestos sampling locations, and Appendix C for complete laboratory analytical results.
List of Abbreviations:
F Friable HSA Homogenous Sampling Area LF Linear Feet Mod Moderate NAD No asbestos Detected NF Non-Friable SF Square Feet
James A. Haley VA Medical Center
TABLE 3: ASBESTOS SAMPLING RESULTS
JAMES A. HALEY VA MEDICAL CENTER – TAMPA, FL
BUILDING 1
HSA Sample ID Location Color Material Description Asbestos Content Quantity Cond. PFD Friable or NF
1A 1B 1C
Penthouse White
Cloth wrap and pink insulation between large round ducts
NAD 500 LF Fair High NF
2A 2B 2C
Penthouse Pink Pink wrap with black insulation and mastic NAD 500 LF Fair High F
3A 3B 3C
Penthouse Blue Blue wrap with black insulation and mastic NAD 500 LF Fair High F
4A 4B 4C
Penthouse White Mastic on pipe ends and junctions
NAD 400 SF Fair High NF
5A 5B 5C
Penthouse Yellow
Yellow wrap with yellow insulation on pipes
NAD 500 LF Fair High NF
6 6A Penthouse Black Black gaskets on valves NAD 50 SF Fair Mod. NF
7A 7B 7C 7D 7E
Penthouse Gray Gray fire proofing NAD 5000 SF Good High F
James A. Haley VA Medical Center
8A 8B 8C
Penthouse Gray Gray Mastic on
HVAC unit doors
NAD 100 SF Fair Mod. NF
9A 9B 9C
Penthouse White
White wrap and insulation on large rectangular HVAC ducts
NAD 500 SF Fair High NF
10A 10B 10C
Penthouse White
White wrap on pipes and insulation with mastic
15% Chrysotile -mastic 500 LF Fair Mod. NF
11A 11B 11C
Penthouse Silver Silver wrap with yellow insulation.
NAD 500 LF Fair Mod. NF
12A 12B 12C
Penthouse Black Black foam insulation on pipes
NAD 200 LF Fair Mod. NF
13A 13B 13C
Penthouse Yellow Yellow paper wrap with yellow insulation.
NAD 500 LF Fair Mod. NF
14A 14B 14C
Penthouse Gray Gray mastic on metal ducts NAD 100 SF Fair Mod. NF
15 15A Penthouse Off-white Hard packing material on pipe elbows
NAD 100 SF Fair Mod. F
16 16A Penthouse White White mastic on metal ducts NAD 50 SF Fair Mod. NF
17 17A Penthouse Brown and silver
Brown and silver pipe joint mastic NAD 50 SF Fair Mod. NF
James A. Haley VA Medical Center
18 18A Penthouse White White mastic between HVAC unit metal seams
NAD 50 SF Fair Mod. NF
19 19A Penthouse Gray
Gray Wrap with silver and white wrap backing and insulation on HVAC units
NAD 800 SF Fair Mod. NF
20 20A Penthouse White White mastic on silver wrap with Brown insulation
NAD 100 SF Fair Mod. NF
21A 21B 21C
Penthouse Orange Orange gasket NAD 5 SF Good Mod. F
22A 22B 22C
Penthouse Black Black foam insulation NAD 200 LF Fair Mod. NF
23A 23B 23C
Penthouse Yellow Yellow insulation in metal pipes
NAD 500 LF Fair Mod. NF
24A 24B 24C
Penthouse Red Red fire proofing (caulking) NAD 50 SF Good Mod. NF
25 25A Penthouse Black Black foam insulation NAD 200 LF Fair Mod. NF
26 26A Penthouse White White mastic on red pipes NAD 50 SF Good Mod. NF
27 27A Penthouse Green Green mastic NAD 50 SF Fair Mod. NF 28 28A Penthouse Gray Gray mastic NAD 50 SF Good. Mod. NF
James A. Haley VA Medical Center
29A 29B 29C
Inside double door area in the basement by the office area
Pink Pink on top of gray fire proofing
NAD 100 SF Good High F
30A 30B 30C 30D 30E
Basement Gray Gray fire proofing NAD 30000 SF Good High F
31A 31B 31C
Next to entrance to the pipe area in basement Blue
Blue fire proofing on top of gray NAD 100 SF Good High F
32A 32B 32C
By unloading ramp in the basement
Dark gray Darker gray fire proofing NAD 100 SF Good High F
33A 33B 33C
Basement White
Large chilled water return pipes; Paper wrap and yellow insulation
NAD 2000 LF Fair Mod. NF
34 34A Basement White
Large chilled water return pipes inside main pipe area. Paper wrap with black insulation and mastic.
NAD 2000 LF Fair Mod. F
35 34A Basement White
GO PSI UP
paper pipe wrap and yellow insulation with
NAD 2000 LF Fair Mod. NF
James A. Haley VA Medical Center
36 36A Basement White
30 LBS MP RET
and 30 PSI GO STEAM pipe paper wrap and yellow insulation
NAD 2000 LF Fair Mod. NF
37A 37B 37C
Basement White
Chilled water return pipes with paper wrap and black insulation with mastic
NAD 2000 LF Fair Mod. F
38 38A Basement White
Chilled water return pipes with paper wrap and yellow insulation
NAD 2000 LF Fair Mod. NF
39 39A Basement White-gray
Hard gray surfacing material on 12 inch pipe
NAD 200 LF Good Low F
40A 40B 40C
Basement offices area Brown Brown baseboard with tan mastic 2% Chrysotile -texture 300 LF Good Mod. NF
41 41A Basement Gray Gray baseboard with tan mastic NAD 300 LF Good Mod. NF
42A 42B 42C
Basement White Drywall with joint compound NAD 15000 SF Fair Mod. F
43A 43B 43C
Basement Beige and brown
Beige and Brown tile with streaks and gray and black mastics.
NAD 400 SF Good Mod. NF
James A. Haley VA Medical Center
44A 44B 44C
Basement White 2x4 with 2x2 random squiggly line ceiling tile
NAD 700 SF Good Mod. F
45A 45B 45C
Basement Red Red fire stop NAD 200 SF Good Low NF
46A 46B 46C
Basement Gray Linoleum stone pattern tile on top of HSA43
NAD 300 SF Good Mod. NF
47A 47B 47C
Basement White White mastic on ductwork NAD 100 SF Good Low NF
48A 48B 48C
Basement Silver Silver duct wrap with yellow insulation
NAD 400 LF Fair Mod. NF
49 49A Basement Silver Silver duct wrap with pink insulation
NAD 200 LF Good Mod. NF
50A 50B 50C
Basement Orange Orange gaskets on blue pipe valves
NAD 25 SF Good Low NF
51A 51B 51C
Basement Gray Gray mastic on metal ducts NAD 250 SF Good Low NF
52A 52B 52C
Basement Silver Silver duct wrap with white insulation
NAD 200 LF Good Mod. NF
53A 53B 53C
Basement Gray with white streaks
12x12 gray Tile with white streaks and
NAD 300 SF Good Mod. NF
James A. Haley VA Medical Center
54A 54B 54C
Basement Black Black foam wrap on pipes NAD 200 LF Fair Mod. NF
55A 55B 55C
Basement White Wrap with mastic and green insulation
NAD 250 LF Good Low NF
56A 56B 56C
Basement Silver
Silver wrap on large rectangular HVAC duct with yellow insulation
NAD 100 LF Good Low NF
57A 57B 57C
Basement White
White cloth wrap and yellow insulation on large HVAC duct
NAD 400 LF Good Mod. NF
58A 58B 58C
Basement Gray Gray fire proofing inside DB-xx Area
NAD 1000 SF Good Mod. F
59A 59B 59C
Basement Gray
Gray compacted fire proofing on columns and ceiling
NAD 10000 SF Good High F
60A 60B 60C 60D 60E
Basement Green/gra y
Green on gray fire proofing NAD 1000 SF Good Mod. F
Basement Dark green
Dark green wrap and yellow insulation on condensate pipe.
NAD 400 LF Good Low NF
James A. Haley VA Medical Center
Basement Yellow Yellow wrap and yellow insulation on steam pipes
NAD 400 LF Good Low NF
Basement Gray Gray mastic on metal ducts NAD 150 SF Good Low NF
Basement Red Red fire caulking NAD 100 SF Good Low NF
65 65A Basement White
White insulation material beneath metal sheet wrap on steam tank
NAD 400 SF Good Low NF
66 66A Basement Yellow Yellow mastic on round metal pipes
NAD 100 SF Good Low NF
67A 67B 67C
Basement White
Wrap with yellow insulation on large round pipes
NAD 2000 LF Good Mod. NF
68A 68B 68C
Basement White
Wrap with yellow insulation on small round pipes
NAD 2000 LF Good Mod. NF
69A 69B 69C
Basement White
White cloth wrap with yellow insulation on Rectangular HVAC ducts
NAD 500 LF Good Mod. NF
James A. Haley VA Medical Center
70A 70B 70C
Basement Silver
Silver duct wrap with yellow insulation and mastic
NAD 500 LF Good Mod. NF
71A 71B 71C
Basement Red Gasket on steam tank NAD 25 SF Good Low NF
72A 72B 72C
Basement Blue Blue wrap on pipe with yellow insulation
NAD 300 LF Fair Mod. NF
73A 73B 73C
Basement White Water line white wrap with yellow insulation NAD 300 LF Fair Mod. NF
74A 74B 74C
Basement White White wrap with black insulation NAD 500 LF Good Mod. F
75A 75B 75C
Basement Black Black wall covering material NAD 2000 SF Fair Mod. NF
76A 76B 76C 76D 76E
Present in hallways and rooms
Cream with olive streaks
9x9 cream floor tile with olive streaks and black mastic
3% Chrysotile - tile;
8% Chrysotile -
50000 SF Good High NF
James A. Haley VA Medical Center
77A 77B 77C 77D 77E 77F 77G 77H 77I
Rooms and hallways Blue
4 inch blue baseboard with yellow mastic
NAD 5000 LF Good Mod. NF
78A 78B 78C 78D 78E 78F 78G 78H 78I 78J 78K
Rooms and hallways Gray
4 inch gray baseboard with yellow mastic
NAD 10000 LF Fair Mod. NF
79A 79B 79C 79D 79E 79F 79G 79H 79I 79J 79K
Rooms and hallways Gray
6-inch gray baseboard with
NAD 5000 LF Good Mod. NF
James A. Haley VA Medical Center
80A 80B 80C
Hallways Red
Red 9x9 tile with black mastic in front of fire apparatus closets
3% Chrysotile - tile;
8% Chrysotile -mastic 1000 SF Good Low NF
81A 81B 81C 81D 81E
Above ceiling in hallways and rooms, and in fire closets
Red Red fire caulking NAD 700 SF Good Low NF
82A 82B 82C 82D 82E 82F 82G 82H 82I 82J 82K
Hallways and rooms White Drywall with joint compound 2% Chrysotile 40000 SF Good Low F
83A 83B 83C
7A hallways Gray-blue
12x12 tile with gray-blue pattern and yellow mastic
<1% Chrysotile 2000 SF Good High NF
84A 84B 84C 84D 84E
In hallways Gray
12x12 gray tile with gray and beige streaks and yellow and black mastics
5% Chrysotile -mastic 15000 SF Good Mod. NF
James A. Haley VA Medical Center
85A 85B 85C 85D 85E
In front of fire apparatus closets Red
12x12 faded red tile in front of fire apparatus closet
5% Chrysotile -mastic 1000 SF Good Low NF
86 86A Inside 7A-718B White
White mastic on black pipe inside fire apparatus closets
NAD 10 SF Fair Low NF
87A 87B 87C
In 7A-736 Brown Brown 4 inch baseboard with yellow mastic
NAD 200 LF Fair Mod. NF
88A 88B 88C
In 7A-736 White 12x12 white tile with gray streaks
4% Chrysotile -mastic 200 SF Good Mod. NF
89A 89B 89C 89D 89E
7th Floor Gray Gray fire proofing 4% Chrysotile 30000 SF Good Mod. F
90A 90B 90C
7th Floor White Paper wrap with yellow insulation and mastic NAD 10000 LF Fair Low NF
91A 91B 91C 91D 91E 91F 91G
Above ceiling in rooms and hallways
Silver Silver duct wrap with mastic and pink insulation
NAD 10000 LF Good Low NF
James A. Haley VA Medical Center
92A 92B 92C 92D 92E
Above ceiling in rooms and hallways
Silver
Silver duct wrap with yellow insulation and mastic
NAD 50000 LF Fair Low NF
93A 93B 93C
7th floor hallways and rooms White
2x4 ceiling tile with large squiggly holes and pinholes
NAD 30000 SF Fair Mod. F
95A 95B 95C 95D 94E
In hallways and rooms White
2x4 ceiling tile with small squiggly lines and pinholes
NAD 50000 SF Fair Mod. F
95A 95B 95C
In hallways and rooms White
Ceiling tile with long squiggly lines and varying size pinholes
NAD 20000 SF Fair Mod. F
96A 96B 96C 96D 96E
Patches in hallways Blue 12x12 blue tile with black mastic 6% Chrysotile -mastic 700 SF Good High. NF
97A 97B 97C 97D 97E 97F 97G
In hallways and rooms
Tan with white and beige streaks
12x12 tan floor tile with white and beige streaks. Yellow mastic
8% Chrysotile -mastic 60000 SF Good High NF
James A. Haley VA Medical Center
98A 98B 98C
7B-715
Blue with a multicolor ed pattern
Blue carpet with multicolored pattern with mastic and vapor barrier
NAD 300 SF Good Mod NF
99 99A Across from 7B- 704B Pink
12x12 pink tile with brown streaks and yellow with black mastic
3% Chrysotile – black mastic 500 SF Good High NF
100A 100B 100C
7th Floor – 7A Light green
12x12 light green tile with mastic NAD 2000 SF Good Mod NF
101A 101B 101C
On metal ducts above the ceiling
Gold on the outside, silver metallic on the inside
Gold mastic on metal ductwork
5% Chrysotile -mastic 3000 SF Good Low NF
102A 102B 102C 102D 102E 102F 102G
Hallways and rooms
White with blue gray streaks
White tile with blue-gray streaks and yellow mastic. Unclear ON what type of tile.
NAD 20000 SF Good Mod. NF
103A 103B 103C 103D 103E
Rooms Gray-blue 4-inch gray-blue baseboard with
NAD 5000 LF Fair Mod. NF
James A. Haley VA Medical Center
104A 104B 104C
In 7B-714 Faded green
4-inch faded green baseboard with yellow mastic
NAD 400 LF Good Mod. NF
105A 105B 105C 105D 105E
Stairwells Blue
Blue with black and white speckles stairwell covering with yellow mastic
NAD 5000 SF Good High NF
106A 106B 106C
In rooms - 7B-
White with blue and brown speckles
White tile with blue and brown speckles and yellow mastic and black mastic
NAD 1000 SF Good Mod NF
107A 107B 107C
In rooms - 7B- 703 Beige
Beige baseboard with yellow mastic NAD 500 LF Good Mod NF
108A 108B 108C
In rooms - 7A-
Beige with blue and red speckles
12x12 beige tile with blue and red speckles and yellow mastic
NAD 1000 SF Good Mod. NF
109A 109B 109C
In rooms - 7A- 717 Brown
4-inch brown baseboard with beige mastic NAD 400 LF Good Mod. NF
110A 110B 110C
In rooms - 7A- 717 Brown
4-inch brown baseboard with beige mastic (same as HSA
109)
NAD 400 LF Good Mod. NF
James A. Haley VA Medical Center
111A 111B 111C 111D 111E 111F 111G 111H 111I 111J 111K
Electric closets Beige Beige fire proofing in electric closets
NAD 7000 SF Good Mod. F
112A 112B 112C 112D 112E 112F 112G 112H 112I 112J 112K
Electric closets Gray Gray fire proofing in electric closets
NAD 7000 SF Good Mod. F
113A 113B 113C
On ducts above ceiling Gray Gray mastic on ducts NAD 5000 SF Good Low NF
114A 114B 114C
In hallways
Tan with white and brown streaks
9x9 tan floor tile with white and brown streaks and black mastic
3% Chrysotile – tile;
15% Chrysotile –
50000 SF Good High NF
James A. Haley VA Medical Center
115A 115B 115C 115D 115E
Above rooms – 7A Gray
Gray fire proofing above patient rooms
NAD 5000 SF Good Mod. F
116A 116B 116C 116D 116E
Hallways and rooms
Tan with large beige and gray streaks
12x12 tan floor tile with large beige and gray streaks
7% Chrysotile -mastic 20000 SF Good High NF
117A 117B 117C 117D 117E
Above rooms on 6th floor Pale green
Pale green fire proofing above rooms on 6th floor
NAD 5000 SF Good Mod. F
118 118A In 6B-616G Beige Beige mastic on ducts on 6th floor NAD 300 SF Good Low NF
119A 119B 119C
6B-616G and 6B- 616M Cream
Cream mastic on ducts and on attached to fire proofing at seams on 6th floor
NAD 400 SF Good Mod. NF
120A 120B 120C
Hallways – 6A White with gray speckles
12x12 white tile with gray speckles and black mastic
4% Chrysotile – black mastic 10000 SF Good High NF
121A 121B 121C
Hallways 6ht floor – 6B Purple Purple baseboard with beige mastic NAD 1000 LF Good Mod. NF
James A. Haley VA Medical Center
122A 122B 122C 122D 122E
In rooms Gray Gray door caulking NAD 3000 LF Good Low NF
123 123A By elevators 10 and 11 on 6th floor Blue Blue wallpaper with mastic NAD 500 SF Fair Low NF
124 124A By elevators 10 and 11 on 7th floor Cream Cream wallpaper with beige mastic NAD 500 SF Fair Low NF
125A 125B 125C
6th Floor Brown
Brown fire proofing in the middle of 6th floor
7% Chrysotile 2000 SF Good Mod. F
126A 126B 126C
Hallways and rooms White
2x2 ceiling tile with squiggly lines and pinholes
NAD 5000 SF Fair Mod. F
127A 127B 127C 127D 127E
6th Floor White
2x2 ceiling tile with long squiggly lines and pinholes
NAD 5000 SF Fair Mod. F
128A 128B 128C
6th Floor Gray Gray fire proofing NAD 25000 SF Good Mod. F
129A 129B 129C
6th Floor Silver Mastic on silver duct wrap with yellow insulation NAD 2000 SF Good Low NF
James A. Haley VA Medical Center
130A 130B 130C
6th Floor White
Paper wrap on pipe with mastic and yellow insulation
NAD 7000 LF Fair Mod. NF
131A 131B 131C
6th Floor Yellow
Yellow insulation on ducts with no wrap
NAD 4000 LF Good Mod. NF
132A 132B 132C
5B rooms Black Black sink undercoating NAD 2000 SF Good Low F
133 133A In 5B-524 Gray Gray sink undercoating NAD 2000 SF Good Low F
134A 134B 134C
5B hallways White White baseboard with beige mastic NAD 500 LF Good Mod. NF
135A 135B 135C
5B Hallways Cream Cream wallpaper with mastic and vapor barrier NAD 20000 SF Fair Mod. NF
135A 135B 135C
5B Above ceiling Silver Silver wrap with white mastic and white insulation
NAD 1000 LF Good Low NF
137A 137B 137C 137D 137E
Above ceiling in hallways and rooms White
Paper wrap with silver backing and yellow insulation
NAD 5000 LF Fair Mod. NF
James A. Haley VA Medical Center
138A 138B 138C 138D 138E 138F 138G
Above ceiling in hallways and rooms
Gray with green
Gray with green fire proofing NAD 10000 SF Good Mod. F
139A 139B 139C
5B Hallways White 2x2 white ceiling tile with dark specks
NAD 2000 SF Fair Mod. NF
140 140A Elevators 10 and 11 on 4th floor White
White caulking around elevator doors NAD 500 LF Fair Low NF
141A 141B 141C
4B Hallways and rooms
Pale light green
Pale light green baseboard with beige mastic NAD 500 LF Good Mod. NF
142A 142B 142C
In electrical closets Gray
Gray wall material in electric closets NAD 5000 SF Good Low F
143A 143B 143C
In 4B-417i Pink Pink insulation beneath black plastic covering NAD 700 LF Good Low NF
144A 144B 144C 144D 144E
Fire apparatus closets Black Black mastic on fire closet pipes 2% Chrysotile 400 SF Fair Low NF
145 145A 4A-448B Pale red Pale red fire proofing (caulking)
NAD 5000 SF Good Low NF
James A. Haley VA Medical Center
146A 146B 146C 146D
Hallways Cream Wallpaper in hallways NAD 20000 SF Good Low NF
147A 147B 147C
Hallways Tan
9x9 tan floor tile with brown streaks and black mastic
3% Chrysotile – tile;
10% Chrysotile – mastic 30000 SF Good High NF
148A 148B 148C
In 3 North Gray and purple
Wallpaper with gray and purple pattern in 3 North
NAD 5000 SF Good Low NF
149A 149B 149C
3rd Floor pipe room Silver Silver wrap with brown insulation NAD 700 LF Fair Mod. NF
150A 150B 150C
3rd Floor pipe room Gray
Gray tile with dark yellow mastic
3% Chrysotile -mastic 250 SF Fair High NF
151A 151B 151C
3rd Floor pipe room White Paper wrap with black insulation NAD 1000 LF Fair Mod. NF
152A 152B 152C
3rd Floor pipe room White Elbow wrap with black insulation NAD 800 SF Good Low F
153A 153B 153C
3rd Floor pipe room Gray
Hard packing material on blue pipe elbows NAD 500 SF Good Low F
154A 154B 154C
3rd Floor pipe room Blue
Blue paper wrap with black
NAD 1000 LF Fair Mod. NF
James A. Haley VA Medical Center
155A 155B 155C
3rd Floor pipe room Blue Blue wrap with black insulation NAD 1000 LF Fair Mod. F
156A 156B 156C
3rd Floor pipe room White
White paper wrap with yellow insulation NAD 1200 LF Fair Mod. NF
157A 157B 157C
3rd Floor pipe room White
Smooth white paper wrap with yellow insulation
NAD 800 LF Fair Mod. NF
158A 158B 158C
3rd Floor pipe room White
White paper wrap with yellow insulation on 1-inch pipe
NAD 300 LF Good Mod. NF
159A 159B 159C
3rd Floor pipe room White Cloth wrap with black insulation NAD 3000 SF Good Mod. F
160A 160B 160C
3rd Floor pipe room White Cloth wrap with yellow insulation NAD 500 LF Good Mod. NF
161A 161B 161C
3rd Floor pipe room Yellow
Smooth yellow wrap with yellow insulation NAD 800 LF Fair Mod. NF
162A 162B 162C
3rd Floor pipe room Silver Silver wrap with yellow insulation NAD 1000 LF Fair Mod. NF
163A 163B 163C 163D 163E
3rd Floor pipe room Gray Gray fireproofing NAD 5000 SF Good Mod. F
James A. Haley VA Medical Center
TABLE 4: ASBESTOS SAMPLING RESULTS
JAMES A. HALEY VA MEDICAL CENTER – TAMPA, FL
BUILDING 1 – GROUND, 2ND, AND 3RD FLOORS
HSA Sample ID Location Color Material Description Asbestos Content Quantity Cond. PFD Friable or NF
1A 1B 1C 1D 1E 1F 1G
Hallways and rooms Gray
4-inch gray baseboard with beige mastic with yellow tint
NAD 15000 LF Good High NF
2A 2B 2C 2D 2E
Hallways and rooms Tan
9x9 tile with brown streak and black mastic
4% Chrysotile - tile;
10% Chrysotile -mastic 50000 SF Good High NF
3A 3B 3C 3D 3E 3F 3G
Hallways and rooms White Drywall with joint compound 2% Chrysotile 45000 SF Good Mod. F
4A 4B 4C 4D 4E
In front of fire apparatus closets Red Red 9x9 tile with black mastic
3% Chrysotile - tile;
8% Chrysotile -
1000 SF Good Mod. NF
James A. Haley VA Medical Center
5A 5B 5C 5D 5E 5F 5G
Above the ceiling in hallways and rooms, and in fire closets
Red Red fire stop NAD 1200 SF Good Low NF
6A 6B 6C
In the auditorium on 2nd floor
Dark tan with black accents
Dark tan vinyl tile with black accent tiles, two layers of tile underneath, and yellow and black mastic
4% Chrysotile - black mastic 400 SF Good High NF
7A 7B 7C 7D 7E
In the auditorium on 2nd floor Black
Black decorative baseboard with beige mastic NAD 400 LF Good Low NF
8A 8B 8C
In hallways and rooms
Tan with white streaks
9x9 tan tile with white streaks, black mastic
4% Chrysotile - tile;
5% Chrysotile -mastic 40000 SF Good High NF
9A 9B 9C
In hallways and rooms
Cream with olive streaks
9x9 cream tile with olive streaks and black mastic
2% Chrysotile - tile;
8% Chrysotile -mastic 40000 SF Good High NF
10A 10B 10C
In hallway junctions
Black with white streaks
9x9 black tile with white streaks and black mastic
4% Chrysotile - tile;
6% Chrysotile -mastic 1500 SF Good High NF
11A 11B 11C
In hallways and rooms Gray
6-inch baseboard with yellow-beige mastic
NAD 2500 LF Good Mod. NF
James A. Haley VA Medical Center
12A 12B 12C
In hallways White with beige splatters
12x12 white tile with beige splatters and yellow mastic
2% Chrysotile – mastic 25000 SF Good High NF
13A 13B 13C
Patches in hallways
Blue with light blue speckles
12x12 blue tile with light blue speckles and black mastic
3% Chrysotile -mastic 500 SF Good High NF
14A 14B 14C
In fire closets Gray Gray plaster inside fire closets NAD 700 SF Good Mod. F
15A 15B 15C 15D 15E
In hallways and rooms
Cream with apricot streaks
12x12 cream tile with apricot streaks and yellow mastic
2% Chrysotile - tile;
4% Chrysotile -mastic Good High NF
16A 16B 16C 16D 16E
In hallways and rooms White
2x4 ceiling tile with squiggly holes and pinholes
NAD Fair Mod. F
17A 17B 17C 17D 17E
Above ceiling in hallways and rooms Silver
Round duct wrap with mastic and yellow insulation NAD 10000 LF Good Mod. NF
James A. Haley VA Medical Center
18A 18B 18C 18D 18E 18F 18G 18H 18I 18J
Above ceiling in hallways and rooms Gray Gray fire proofing 8% Chrysotile 80000 SF Good Mod. F
19A 19B 19C
Above ceiling in hallways and rooms White
Paper pipe wrap with silver backing and yellow insulation
NAD 10000 LF Fair Mod. NF
20A 20B 20C 20D
Above ceiling in hallways and rooms White Pipe elbow mastic NAD 3000 SF Fair Mod. NF
21A 21B 21C
Above ceiling in hallways and rooms Beige Beige duct joint filling mastic 6% Chrysotile 1000 SF Good Low NF
22A 22B 22C
In hallways and rooms Pink 12x12 pink tile with black mastic 15% Chrysotile – black mastic 3000 SF Good High NF
23A 23B 23C
By crosswalk to USF exit
Orange-tan with beige speckles
12x12 orange-tan tile with beige speckles and yellow mastic
10% Chrysotile – black mastic 500 SF Good High NF
24 24A By crosswalk to USF exit Yellow
12x12 yellow tile with yellow
NAD 50 SF Good Mod. NF
James A. Haley VA Medical Center
25A 25B 25C
In hallways and rooms
Dark green
4-inch dark green baseboard with yellow mastic
NAD 500 LF Good Mod. NF
26A 26B 26C 26D 26E 26F 26G
Above ceiling in hallways and rooms Silver
Silver wrap with mastic and yellow insulation square/rectangula r ducts
NAD 10000 LF Good Mod. NF
27A 27B 27C 27D
Above ceiling in hallways and rooms Gold Gold mastic on ductwork 4% Chrysotile 3000 SF Good Low NF
28A 28B 28C
In hallways and rooms Cream
Cream seamless floor with leveler and mastic NAD 500 SF Good High NF
29 29A Entrance to 2D- 219B hallway Gray
12x12 gray tile with yellow mastic on HSA8 NAD 150 SF Good High NF
30A 30B 30C
In hallways and rooms
Tan with brown streaks
9x9 tan tile with brown streaks.
Black mastic.
NAD 10000 SF Good High NF
31 31A In 2C-242A Wood pattern
Vinyl wood pattern with yellow mastic NAD 500 SF Good Mod. NF
32A 32B 32C
In fire closets Gray Gray hard mastic on black pipe joints
2% Chrysotile 500 SF Good Low NF
James A. Haley VA Medical Center
33A 33B 33C
In hallways and rooms
Tan with beige and gray splatters
12x12 tan tile with beige and gray splatters, gray mastic
6% Chrysotile – black mastic 2000 SF Good High NF
34 34A 2C-424 Beige
Beige vinyl floor tile with beige, blue, red dot pattern with beige mastic
NAD 300 SF Good Mod. NF
35 35A In stairwells Blue Blue vinyl stair covering NAD 3000 SF Good High NF
36 36A Cafeteria on 2nd floor Wood
Vinyl wood pattern flooring with gray mastic
NAD 300 SF Good High NF
37 37A By entrance to SICU hallway
Blue with orange and blue streak
12x12 blue tile with orange and blue streaks
8% Chrysotile – black mastic 4000 SF Good High NF
38A 38B 38C
Above ceiling in hallways and rooms Silver Silver wrap with pink insulation 8% Chrysotile – wrap 5000 LF Good Low NF
39A 39B 39C
Above ceiling in hallways and rooms
Gray with green
Gray with green fireproofing NAD 10000 SF Good Mod. F
40A 40B 40C
Hallways and rooms White
Ceiling tile with small and large pinholes NAD 80000 SF Fair Mod. F
41A 41B 41C
In hallways and rooms Cream Cream baseboard with beige mastic NAD 2000 LF Good Mod. NF
James A. Haley VA Medical Center
42A 42B 42C
In hallways Beige Wallpaper with gray mastic NAD 10000 SF Good Mod. NF
43A 43B 43C
In hallways Yellow Yellow mastic behind white wall panels
NAD 10000 SF Good Low NF
44A 44B 44C
Cafeteria on 2nd floor Black Black baseboard with beige mastic NAD 150 LF Good Mod. NF
45A 45B 45C
In hallways Beige Textured, beige wallpaper NAD 5000 SF Good Mod. NF
46 46A In 2B-225A Gray and white
20x20 vinyl gray and white tile.
Black mastic
NAD 400 SF Good High NF
47A 47B 47C
Library Beige and gray/blue
Beige and gray/ blue vinyl tile in library w/ beige mastic
NAD 400 SF Good Mod. NF
48A 48B 48C
Electrical closets Beige Beige fireproofing in electrical closets
NAD 10000 SF Good Mod. F
49A 49B 49C
Electrical closets Painted gray
Painted gray fireproofing in electrical closets NAD 10000 SF Good Mod. F
50A 50B 50C
Electrical closets White with gray speckles
12x12 white with gray speckles tile in electric closets
NAD 5000 SF Good Mod. NF
51A 51B 51C
Electrical closets and rooms and hallways Dark blue
Dark blue baseboard with
NAD 3000 LF Good Low NF
James A. Haley VA Medical Center
52A 52B 52C
Patient library Dark brown
Dark brown baseboard with beige mastic NAD 500 LF Good Mod NF
53A 53B 53C
2C-242 Light gray Light gray baseboard with beige mastic
NAD 400 LF Good Mod NF
54 54A In FDb-2A-237-1
Blue with red and orange speckles
Blue carpet with red and orange speckles. Green mastic.
NAD 300 SF Good Mod. NF
55A 55B 55C 55D 56E
Hallways Clear Clear mastic behind gray wall panels
NAD 1000 SF Good Low NF
56 56A Corner across from 2D-220 White White baseboard with clear mastic NAD 200 LF Good Mod. NF
57A 57B 57C
Chapel on 1st floor White White popcorn ceiling 5% Chrysotile 400 SF Good Low F
58A 58B 58C
Hallways by fire closets Red
12x12 red tile on top of beige tile with yellow and black mastics
4% Chrysotile – beige tile; 10% Chrysotile – mastic 700 SF Good Mod. NF
59A 59B 59C 59D
Hallways and rooms
White with gray and tan speckles
12x12 White tile with gray and tan speckles, yellow mastic
3% Chrysotile – tile;
10% Chrysotile – mastic 5000 SF Good High NF
60A 60B 60C
Hallways Pale orange
Pale orange baseboard with
NAD 600 LF Good Mod. NF
James A. Haley VA Medical Center
61A 61B 61C
Lab area White White sink undercoating NAD 300 SF Good Low NF
62A 62B 62C
Waiting lobby on 1st floor Light pink
12x12 light pink tile with orange and blue speckles on beige tile with yellow and black mastic
4% Chrysotile – beige tile; 8% Chrysotile – mastic 400 SF Good High NF
63A 63B 63C
By dental office suites Gray
12x12 gray tile with gray speckles, yellow and beige/black mastics
7% Chrysotile – black mastic 200 SF Fair Mod. NF
64 64A 64B In fire closets Soft yellow Soft yellow mastic on pipes NAD 100 SF Fair Low NF
65 65A 1st floor reception area
Gray with pearl speckles
Gray terrazzo flooring with pearl speckles and yellow mastic
NAD 500 SF Good High NF
66 66A Dining room on ground floor Black
Black baseboard in dining area on ground floor.
Beige mastic.
NAD 150 LF Fair Mod. NF
67A 67B 67C
In hallways Brown Brown baseboard with beige mastic NAD 700 LF Fair Mod. NF
68A 68B 68C
In mail room Beige with gray streaks
Beige tile with gray streaks in mail room.
Yellow mastic
NAD 300 SF Fair High NF
James A. Haley VA Medical Center
69A 69B 69C
ER Lobby Green Green tile on top of beige tile.
Yellow mastic.
3% Chrysotile – beige tile; 7% Chrysotile -mastic 500 SF Fair High NF
70A 70B 70C
Pool in the basement Brown Brown pool mastic covering 3% Chrysotile – mastic 1500 SF Fair Low NF
71A 71B 71C
SPD office
Beige with blue and pink splatters
12x12 beige tile with blue and pink splatters.
Yellow mastic.
NAD 400 SF Fair High NF
72A 72B 72C
Safety office Gray Gray vinyl panels on tile, yellow mastic
2% Chrysotile – beige tile; 7% Chrysotile -mastic 400 SF Good Mod. NF
73A 73B 73C
Fire closets Black
Hard black-brown mastic inside fire closets on walls
4% Chrysotile 300 SF Fair Low F
74A 74B 74C
Safety office Pink-beige Pink-beige baseboard with yellow mastic
NAD 250 LF Good Mod. NF
75A 75B 75C
First floor lab Light blue
Light blue fireproofing above lab area on first floor
NAD 1000 SF Good Mod. F
James A. Haley VA Medical Center
4.2 Asbestos Sampling Methods
The surveyor conducted a visual inspection of every safe and reasonably accessible room and space of the building and identified homogeneous areas based on the texture, appearance, and use of suspect ACM. Bulk samples of all friable and non-friable suspect ACM were collected, as well as a representative number of samples from each homogeneous area following the EPA's simplified random sampling method (EPA560/585-030a). Good Industrial Hygiene practices were followed when collecting bulk samples in order to minimize fiber release. Every precaution was taken to prevent asbestos exposure to the surveyor, the building occupants, and the public.
All sample locations were logged with an appropriate description and the locations were marked on any available drawings. A unique sequential numbering system was used to identify each area. Each bulk sample was placed in a labeled bag, which was immediately marked with its sample number. A chain of custody form was submitted with each sample group for analysis and signed by the receiving laboratory personnel who handled the samples. The samples were analyzed by EMSL Analytical, a National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory, for asbestos content.
4.3 Regulatory Requirements
Demolition: According to NESHAP, 40CFR61 Subpart M, demolition is defined as the wrecking or taking out of any load-supporting structural member of a facility together with any related handling operations or the intentional burning of any facility.
The final NESHAP Rule provides classification for regulated asbestos containing material as follows:
• Friable asbestos material;
• Category I non-friable ACM that has become friable;
• Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading; or
• Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by forces expected to act upon the material in the course of demolition or renovation operations.
If the total asbestos content is determined to be trace to 10%, the owner must either assume that the material contains greater than 1% asbestos and treat the material as regulated asbestos-containing material (RACM) or have the material verified/quantified by point counting. If after point counting, the material is quantified as 1% or less, it is not regulated by the NESHAP.
The Occupational Safety and Health Administration (OSHA) considers material that contains any amount of asbestos as asbestos-containing and requires compliance with OSHA regulations. The demolition of a structure with materials present that contain any amount of asbestos is considered by OSHA as an asbestos
James A. Haley VA Medical Center abatement, and all applicable OSHA rules must be complied with during the demolition.
Notification: Notification is required to the local regulatory agency:
1. Ten (10) working days prior to a demolition.
2. Ten (10) working days prior to a renovation operation, if the amount of asbestos material removed or impacted is greater than 160 SF on all building components (i.e. floor tile, mastic, GWBS, etc.) or 260 LF on pipes.
3. One (1) day prior to demolition, if the building has been condemned and is structurally unsound as determined by the appropriate agency.
Notification must be sent by certified mail with return receipt or hand delivered to the Georgia Environmental Protection Division. The demolition contractor must wait ten (10) working days (Monday – Friday) from the postmarked date of mailing or the date of hand delivery to commencement of demolition. Any change to the start date of the demolition requires notification to the agency by phone, followed by a written revision to the Notification Form.
4.4 Statutory Requirements
The regulatory agency responsible for the oversight of the rules pertaining to asbestos-containing building materials (ACBM) is the Environmental Protection Agency (EPA). The regulations state that prior to demolition or renovation, a facility survey must be conducted in accordance to section 40 CFR 61-M National Emission Standards for Hazardous Air Pollutants; Asbestos NESHAP Revisions, Final Rule.
Enforcement of these rules was passed on to the states. In the State of Georgia they are enforced by the Environmental Protection Division. Some counties have developed an enforcement division to carry out the responsibilities and have developed environmental and asbestos ordinances with which compliance is required.
5.0 OBSERVATIONS
• Loose fireproofing observed on top of most ceiling tiles and HVAC ducts on all floors.
James A. Haley VA Medical Center
6.0 LIMITATIONS
The materials sampled in this survey were subject to accessibility. This survey is limited to the Building 1 only located at the James A. Haley VA Medical Center in Tampa, Florida.
OHC warrants that the investigations and methodology reflect the prevailing standard of work practices in the environmental consulting field. If it is expected that materials outside the scope of this survey are to be disturbed, they must be presumed ACM until the materials can be analyzed by an accredited asbestos building inspector.
• Elevator shafts were not sampled due to confined space restrictions
• AC units were active during the time of the survey, therefore, any insulation within in these units was not sampled.
• Tile of different colors in the middle of hallways were not sampled due to trip hazards as per discussion with James Watson, CIH, in the Safety Department of the James A. Haley VAMC.
• Some confined areas were not accessible above the ceiling due to size restrictions of the mobile containment unit.
• Time limitations were encountered when checking areas where patients were constantly present.
• Some materials, including terrazzo flooring on the 1st floor and white panels on walls, could not be sampled without significantly damaging these materials. The materials were sampled where already damaged or broken.
7.0 DOCUMENT CONTENT
This document has been prepared for the exclusive use by Biosphere International and the Veterans Health Administration. The knowledge of the consultant is based upon current information and research. If local knowledge indicates error, omissions, or inaccuracy, please notify the consultant.
James A. Haley VA Medical Center
APPENDIX A:
PHOTOGRAPHS
BASEMENT, FLOORS 3-7,
AND PENTHOUSE
James A. Haley VA Medical Center
[HSA-1] No Asbestos Detected Cloth wrap and pink insulation between large round ducts
[HSA-2] No Asbestos Detected Pink wrap with black insulation and mastic
James A. Haley VA Medical Center
[HSA-3] No Asbestos Detected Blue wrap with black insulation and mastic
[HSA-4] No Asbestos Detected Mastic on pipe ends and junctions
James A. Haley VA Medical Center
[HSA-5] No Asbestos Detected Yellow wrap with yellow insulation on pipes
[HSA-6] No Asbestos Detected Black gaskets on valves
James A. Haley VA Medical Center
[HSA-7] No Asbestos Detected Gray fire proofing
[HSA-8] No Asbestos Detected Gray Mastic on HVAC unit doors
James A. Haley VA Medical Center
[HSA-9] No Asbestos Detected White wrap and insulation on large rectangular HVAC ducts
[HSA-10] 15% Chrysotile - mastic White wrap on pipes and insulation with mastic
James A. Haley VA Medical Center
[HSA-11] No Asbestos Detected Silver wrap with yellow insulation.
[HSA-12] No Asbestos Detected Black foam insulation on pipes
James A. Haley VA Medical Center
[HSA-13] No Asbestos Detected Yellow paper wrap with yellow insulation.
[HSA-14] No Asbestos Detected Gray mastic on metal ducts
James A. Haley VA Medical Center
[HSA-15] No Asbestos Detected Hard packing material on pipe elbows
[HSA-16] No Asbestos Detected White mastic on metal ducts.
James A. Haley VA Medical Center
[HSA-17] No Asbestos Detected Brown and silver pipe joint mastic
[HSA-18] No Asbestos Detected White mastic between HVAC unit metal seams
James A. Haley VA Medical Center
[HSA-19] No Asbestos Detected Gray Wrap with silver and white wrap backing and…