CAD_Drawings_Overall_Floor_Plan_Level_02.pdf
PDF 2 MB Posted
- Attached to
- Supply: Drawings, Designs, Plans, patient lifts, booms, modular headwalls equipment and installation
- Solicitation number
- 36C24819Q0115
About this file
36C24819Q0115 CAD Drawings Overall Floor Plan Level 02.pdf
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M A
O
B M
A C D E F H J K L
G
4.2
F.3
5.3
6.3
7.8
E.8
5.8
7.4
8.5
9.3
9.7
L.5K.5J.5H.5
F.8
1.5
2.5
F.5E.5D.5C.5B.6B.3A.5
5.5
4.5
3.2
STAIR
LEVEL
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
6, NEG
ISOLATION
ANTEROOM
ANTEROOMSICU
PATIENT
ROOM
5, NEG
ISOLATION
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
CORRIDOR
PATIENT
ELEV
EMPL
WELLNESS
TOILET,
STAFF
CONSULTATION
ROOM CONSULTATION
ROOM
VENDING
MACHINE
AREA
CORRIDOR
WAITING/
LOUNGE
CO
RR
ID
OR
TOILET,
PUBLIC
TOILET,
FAMILY
ASSIST
TOILET,
FAMILY
ASSIST
TOILET,
PUBLIC
STORAGE,
EQUIPMENT
DISPOSAL
CHUTE
ROOM,
LINEN
BLOOD
GAS
LAB
DISPOSAL
CHUTE
ROOM,
TRASH
WC
ALCOVE
FS
CART
STORAGE
STORAGE,
MEDICAL
GAS
HACNOURISHMENT
STATION
UTILITY
ROOM,
CLEAN,
LINEN
MEDICATION
ROOM
WARD
CLERK
NURSE
STATION,
ICU
CONFERENCE/
REPORT
ROOM
CC
ALCOVE
NU
RS
E
SU
B-
ST
AT
IO
N
NU
RS
E
SU
B-
ST
AT
IO
N
NU
RS
E
SU
B-
ST
AT
IO
N
TEAM
ROOM
UTILITY,
SOILED
STORAGE,
EMS
SERVICE
ELEV
OI&T SIGNAL ELEC
LOCKER
ROOM
STAFF
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
NURSE
SUB-STATION
NURSE
SUB-STATION
NURSE
SUB-STATION
NURSE
SUB-STATION
CORRIDOR
NU
RS
E
SU
B-
ST
AT
IO
N
CO
RR
ID
OR
CORRIDOR
STORAGE,
EQUIPMENT
LOUNGE,
STAFF
TOILET,
STAFF
CORRIDOR
OFFICEOFFICE
OFFICE
OFFICE
CONFERENCE
PUBLIC
ELEV
TOILET,
FAMILY
ASSIST
TOILET,
STAFF
PATIENT
SHOWER ANTEROOM
ANTEROOM
STAIR
LEVEL
AN
TE
RO
OM
AN
TE
RO
OM
NURSE
SUB-STATION
NURSE
SUB-STATION
NURSE
SUB-STATION
NU
RS
E
SU
B-
ST
AT
IO
N
NU
RS
E
SU
B-
ST
AT
IO
N
UTILITY
ROOM,
CLEAN,
LINEN
BLOOD
GAS
LAB
NOURISHMENT
STATION
TOILET,
STAFF
TOILET,
STAFF
MEDICATION
ROOMELECSIGNALOI&T
TEAM
ROOM
OFFICE
OFFICE
TOILET,
PUBLIC
STORAGE,
MEDICAL
GAS
HAC
TOILET,
STAFF
NOURISHMENT
STATION
FS
CART
STORAGE
MEDICATION
ROOM
TOUCHDOWN
SPACE
CORRIDOR
NURSE
STATION,
ICU
WARD
CLERK
CONFERENCE/
REPORT
ROOMUTILITY,
SOILED
NURSE
STATION,
ICU
CORRIDOR
FS
CART
STORAGE
LOUNGE,
STAFF
CONSULTATION
ROOM
CONSULTATION
ROOM
GREETER
CORRIDOR
W
AI
TI
NG
LO
UN
GE
KIOSK,
PATIENT
EDUC/
RESRC
KIOSK,
PATIENT
EDUC/
RESRC
VI
SI
TO
R
KI
TC
HE
NE
TT
E
TEAM
ROOM
CORRIDOR
NURSE
SUB-STATION
NURSE
SUB-STATION
NURSE
SUB-STATION
NURSE
SUB-STATION NURSE
SUB-STATION
STORAGE,
EQUIPMENT
EXISTING
CHAPEL
3.5
3.7
F.7
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
EL
EV
AT
OR
EL
EV
AT
OR
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
10, NEG
ISOLATION
CICU
PATIENT
ROOM
11, NEG
ISOLATION
CICU
PATIENT
ROOM
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
CONFERENCE/
REPORT
ROOM
MICU
PATIENT
ROOM
4, NEG
ISOLATION
MICU
PATIENT
ROOM
5, NEG
ISOLATION
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
ALCOVE
ELEVATOR
ELEVATOR
6.1
7.1
7.5 7.6
8.4
NURSE
SUB-STATION
NURSE
SUB-STATION
CORRIDOR
CO
RR
ID
OR
CORRIDOR
CO
RR
ID
OR
CO
RR
ID
OR
CO
RR
ID
OR
WAITING/
LOUNGE
CORRIDOR
ALCOVE
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
NU
RS
E
SU
B-
ST
AT
IO
N
NURSE
WORKROOM
EXISTING
CHAPEL
EXISTING
ICU
MOBILE
X-RAY
ALCOVE
STAIR
LEVEL
2 CC
ALCOVE
CC
ALCOVE
WARD
CLERK
KIOSK,
PATIENT
EDUC/
RESRC
ALCOVE
NURSE
WORKROOM
NURSE
WORKROOM
BATHROOM,
PATIENT
CO
RR
ID
OR
CORRIDOR
CORRIDOR
CO
RR
ID
OR
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
CORRIDOR
CORRIDOR
ALCOVE
CO
RR
ID
OR
AA M.2
M.4 N
6.5
ABACAD
104' - 6"
112' - 5"
19'-0" 20'-6" 10'-8" 10'-0" 9'-10" 10'-2" 11'-6" 11'-8" 11'-8" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 9'-6" 5'-6" 6'-1" 8'-9" 9'-8" 15'-0" 15'-0" 15'-0" 15'-0" 11'-6" 11'-6" 13'-0" 12'-10" 2'-11" 7'-11 1/4" 16'-1 3/4"
'-6
'-0
'-4
'-0
4'- 9" 8'-
5" 1'-
" 7'-
9" 5'-
8"
1'- 7"
5'-
/2
"3'-
1/ 2" 6'- 0"
3'- 0"
4'-
1/ 2"4'-
1/
2" 4'- 0"
'-0
5'-
0"
'-0
'-1
0" 4'-
2" 9'-
0" 7'-
0" 6'-
0"
'-0
'-0
'-1 0"
9'- 0"
9'- 0"
M
AT
CH
LI
NE
RE
F
F1
0.
A-
2-
M
AT
CH
LI
NE
RE
F
F1
0.
A-
2-
M
AT
CH
LI
NE
RE
F
F3
0.
A-
2-
MATCHLINE
SEE /F1 100.A-102-1
MATCHLINE
SEE /F1 100.A-102-6
M
AT
CH
LI
NE
RE
F
F1
0.
A-
2-
M
AT
CH
LI
NE
RE
F
F1
0.
A-
2-
M
AT
CH
LI
NE
RE
F / 1
0.
A-
2-
MATCHLINE
SEE /F1 100.A-102-4
MATCHLINE
SEE /F1 100.A-102-5
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
PRINTER
SICU
PATIENT
ROOM
FLOOR PLAN GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
ALL UNMARKED PARTITIONS ARE TYPE A3. ALL COLUMN FURRING TO BE PARTITION
TYPE F2 UNLESS NOTED OTHERWISE.
ALL WINDOW & DOOR PLAN OPENINGS ARE DIMENSIONED ON AREA PLANS.
FOR FIRE AND LIFE SAFETY PLANS, REFER TO G1 DRAWINGS.
ROOF PLAN SHOWN FOR REFERENCE ONLY. REFER TO ROOF PLAN FOR NOTES AND
DIMENSIONS.
REFER TO A2 SERIES DRAWINGS, EXTERIOR ELEVATIONS, A3 BUILDING AND WALL
SECTIONS.
REFER TO A6 SERIES FOR ALL PARTITIONS, DOORS, WINDOWS, AND ACCESSORIES.
INSTALL APPROPRIATE MANUFACTURED EXPANSION JOINT COVERS AT ALL VISIBLE
BUILDING EXPANSION JOINTS. TOP OF COVER OF FLOOR EXPANSION JOINT
COVERS TO BE FLUSH WITH TOP OF FINISHED FLOOR.
ALL PLAN DIMENSIONS ARE TAKEN TO THE CENTERLINE OF COLUMNS AND TO THE
OUTERMOST SURFACE OF THE WALL (INCLUDING TILE, STONE, PLASTER, ETC.
EXCLUDING TRIM) UNLESS NOTED OTHERWISE.
INSTALL BLOCKING AS REQUIRED TO SUPPORT WALL MOUNTED DEVICES.
AT ALL SPANDREL GLASS LOCATIONS, FACE OF INTERIOR WALL TO BE CONTINUOUS
WITH ADJACENT WALL.
REFER TO A-551 FOR INTERIOR EXPANSION JOINT DETAILS.
GENERAL DIMENSIONS PROVIDED ON FLOOR PLANS AND AREA PLANS DO NOT
REFLECT THE ROUGH OPENING DIMENSIONS REQUIRED FOR COORDINATION WITH
MASONRY JOINT COURSING. CONTRACTOR IS TO PROVIDE ROUGH OPENING
FRAMING DIMENSIONS CONSISTENT WITH ENLARGED ARCHITECTURAL
PLAN/SECTION DETAILS (A5 SERIES SHEETS), AND WINDOW SCHEDULE/DETAILS (A6
SERIES). CONTRACTOR TO SUBMIT RFI FOR ANY ROUGH OPENING DIMENSIONS NOT
GIVEN IN DETAILING FOR CLARIFICATION REQUIRED.
13. ALL COLUMN FURRING TO STOP AT 6" ABOVE CEILINGS. ( TYP.)
FLOOR PLAN LEGEND
MATCH LINE
PARTITION TAG
REFER TO PARTITION SCHEDULE
BUILDING SECTION TAG
WALL SECTION TAG
EXTERIOR ELEVATION TAG
PLAN REFERENCE TAG
ROOM NAME
COLUMN GRID
DESIGNATIONS
KEYED NOTE
KEYED NOTES ONLY APPLY TO THIS SHEET
SHEET REFERENCE
H4 A-211 INTERIOR ELEVATION TAG
ROOM NUMBER
NEW DOOR
WITH DOOR TAG
REF DOOR SCHED
NEW WINDOW
WITH WINDOW MARK
REF GLAZING ELEVATIONS
A-431 A6
MATCHLINE
SEE /XX A101
A1 X
ROOM NAME
02A
1002a 28
SMOKE PARTITION
1-HOUR FIRE BARRIER
SMOKE BARRIER
2-HOUR FIRE BARRIER
3-HOUR FIRE BARRIER
A-201 A6
A-301 A6
NURSE
TRAVEL
DISTANCE
NURSE
SIGHT
LINES
100'
KEYED NOTES
NUMBER DESCRIPTION
M A
O
B M
A C D E F H J K L
G
4.2
F.3
5.3
6.3
7.8
E.8
5.8
7.4
8.5
9.3
9.7
L.5K.5J.5H.5
F.8
1.5
2.5
F.5E.5D.5C.5B.6B.3A.5
5.5
4.5
3.2
STAIR
LEVEL
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
6, NEG
ISOLATION
ANTEROOM
ANTEROOMSICU
PATIENT
ROOM
5, NEG
ISOLATION
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
CORRIDOR
PATIENT
ELEV
EMPL
WELLNESS
TOILET,
STAFF
CONSULTATION
ROOM CONSULTATION
ROOM
VENDING
MACHINE
AREA
CORRIDOR
WAITING/
LOUNGE
CO
RR
ID
OR
TOILET,
PUBLIC
TOILET,
FAMILY
ASSIST
TOILET,
FAMILY
ASSIST
TOILET,
PUBLIC
STORAGE,
EQUIPMENT
DISPOSAL
CHUTE
ROOM,
LINEN
BLOOD
GAS
LAB
DISPOSAL
CHUTE
ROOM,
TRASH
WC
ALCOVE
FS
CART
STORAGE
STORAGE,
MEDICAL
GAS
HACNOURISHMENT
STATION
UTILITY
ROOM,
CLEAN,
LINEN
MEDICATION
ROOM
WARD
CLERK
NURSE
STATION,
ICU
CONFERENCE/
REPORT
ROOM
CC
ALCOVE
NU
RS
E
SU
B-
ST
AT
IO
N
NU
RS
E
SU
B-
ST
AT
IO
N
NU
RS
E
SU
B-
ST
AT
IO
N
TEAM
ROOM
UTILITY,
SOILED
STORAGE,
EMS
SERVICE
ELEV
OI&T SIGNAL ELEC
LOCKER
ROOM
STAFF
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
SICU
PATIENT
ROOM
NURSE
SUB-STATION
NURSE
SUB-STATION
NURSE
SUB-STATION
NURSE
SUB-STATION
CORRIDOR
NU
RS
E
SU
B-
ST
AT
IO
N
CO
RR
ID
OR
CORRIDOR
STORAGE,
EQUIPMENT
LOUNGE,
STAFF
TOILET,
STAFF
CORRIDOR
OFFICEOFFICE
OFFICE
OFFICE
CONFERENCE
PUBLIC
ELEV
TOILET,
FAMILY
ASSIST
TOILET,
STAFF
PATIENT
SHOWER ANTEROOM
ANTEROOM
STAIR
LEVEL
AN
TE
RO
OM
AN
TE
RO
OM
NURSE
SUB-STATION
NURSE
SUB-STATION
NURSE
SUB-STATION
NU
RS
E
SU
B-
ST
AT
IO
N
NU
RS
E
SU
B-
ST
AT
IO
N
UTILITY
ROOM,
CLEAN,
LINEN
BLOOD
GAS
LAB
NOURISHMENT
STATION
TOILET,
STAFF
TOILET,
STAFF
MEDICATION
ROOMELECSIGNALOI&T
TEAM
ROOM
OFFICE
OFFICE
TOILET,
PUBLIC
STORAGE,
MEDICAL
GAS
HAC
TOILET,
STAFF
NOURISHMENT
STATION
FS
CART
STORAGE
MEDICATION
ROOM
TOUCHDOWN
SPACE
CORRIDOR
NURSE
STATION,
ICU
WARD
CLERK
CONFERENCE/
REPORT
ROOMUTILITY,
SOILED
NURSE
STATION,
ICU
CORRIDOR
FS
CART
STORAGE
LOUNGE,
STAFF
CONSULTATION
ROOM
CONSULTATION
ROOM
GREETER
CORRIDOR
W
AI
TI
NG
LO
UN
GE
KIOSK,
PATIENT
EDUC/
RESRC
KIOSK,
PATIENT
EDUC/
RESRC
VI
SI
TO
R
KI
TC
HE
NE
TT
E
TEAM
ROOM
CORRIDOR
NURSE
SUB-STATION
NURSE
SUB-STATION
NURSE
SUB-STATION
NURSE
SUB-STATION NURSE
SUB-STATION
STORAGE,
EQUIPMENT
EXISTING
CHAPEL
3.5
3.7
F.7
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
EL
EV
AT
OR
EL
EV
AT
OR
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
CICU
PATIENT
ROOM
10, NEG
ISOLATION
CICU
PATIENT
ROOM
11, NEG
ISOLATION
CICU
PATIENT
ROOM
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
CONFERENCE/
REPORT
ROOM
MICU
PATIENT
ROOM
4, NEG
ISOLATION
MICU
PATIENT
ROOM
5, NEG
ISOLATION
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
MICU
PATIENT
ROOM
ALCOVE
ELEVATOR
ELEVATOR
6.1
7.1
7.5 7.6
8.4
NURSE
SUB-STATION
NURSE
SUB-STATION
CORRIDOR
CO
RR
ID
OR
CORRIDOR
CO
RR
ID
OR
CO
RR
ID
OR
CO
RR
ID
OR
WAITING/
LOUNGE
CORRIDOR
ALCOVE
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
NU
RS
E
SU
B-
ST
AT
IO
N
NURSE
WORKROOM
EXISTING
CHAPEL
EXISTING
ICU
MOBILE
X-RAY
ALCOVE
STAIR
LEVEL
2 CC
ALCOVE
CC
ALCOVE
WARD
CLERK
KIOSK,
PATIENT
EDUC/
RESRC
ALCOVE
NURSE
WORKROOM
NURSE
WORKROOM
BATHROOM,
PATIENT
CO
RR
ID
OR
CORRIDOR
CORRIDOR
CO
RR
ID
OR
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
BATHROOM,
PATIENT
CORRIDOR
CORRIDOR
ALCOVE
CO
RR
ID
OR
AA M.2
M.4 N
6.5
ABACAD
104' - 6"
112' - 5"
19'-0" 20'-6" 10'-8" 10'-0" 9'-10" 10'-2" 11'-6" 11'-8" 11'-8" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 9'-6" 5'-6" 6'-1" 8'-9" 9'-8" 15'-0" 15'-0" 15'-0" 15'-0" 11'-6" 11'-6" 13'-0" 12'-10" 2'-11" 7'-11 1/4" 16'-1 3/4"
'-6
'-0
'-4
'-0
4'- 9" 8'-
5" 1'-
" 7'-
9" 5'-
8"
1'- 7"
5'-
/2
"3'-
1/ 2" 6'- 0"
3'- 0"
4'-
1/ 2"4'-
1/
2" 4'- 0"
'-0
5'-
0"
'-0
'-1
0" 4'-
2" 9'-
0" 7'-
0" 6'-
0"
'-0
'-0
'-1 0"
9'- 0"
9'- 0"
M
AT
CH
LI
NE
RE
F
F1
0.
A-
2-
M
AT
CH
LI
NE
RE
F
F1
0.
A-
2-
M
AT
CH
LI
NE
RE
F
F3
0.
A-
2-
MATCHLINE
SEE /F1 100.A-102-1
MATCHLINE
SEE /F1 100.A-102-6
M
AT
CH
LI
NE
RE
F
F1
0.
A-
2-
M
AT
CH
LI
NE
RE
F
F1
0.
A-
2-
M
AT
CH
LI
NE
RE
F / 1
0.
A-
2-
MATCHLINE
SEE /F1 100.A-102-4
MATCHLINE
SEE /F1 100.A-102-5
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
PRINTER
SICU
PATIENT
ROOM
FLOOR PLAN GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
ALL UNMARKED PARTITIONS ARE TYPE A3. ALL COLUMN FURRING TO BE PARTITION
TYPE F2 UNLESS NOTED OTHERWISE.
ALL WINDOW & DOOR PLAN OPENINGS ARE DIMENSIONED ON AREA PLANS.
FOR FIRE AND LIFE SAFETY PLANS, REFER TO G1 DRAWINGS.
ROOF PLAN SHOWN FOR REFERENCE ONLY. REFER TO ROOF PLAN FOR NOTES AND
DIMENSIONS.
REFER TO A2 SERIES DRAWINGS, EXTERIOR ELEVATIONS, A3 BUILDING AND WALL
SECTIONS.
REFER TO A6 SERIES FOR ALL PARTITIONS, DOORS, WINDOWS, AND ACCESSORIES.
INSTALL APPROPRIATE MANUFACTURED EXPANSION JOINT COVERS AT ALL VISIBLE
BUILDING EXPANSION JOINTS. TOP OF COVER OF FLOOR EXPANSION JOINT
COVERS TO BE FLUSH WITH TOP OF FINISHED FLOOR.
ALL PLAN DIMENSIONS ARE TAKEN TO THE CENTERLINE OF COLUMNS AND TO THE
OUTERMOST SURFACE OF THE WALL (INCLUDING TILE, STONE, PLASTER, ETC.
EXCLUDING TRIM) UNLESS NOTED OTHERWISE.
INSTALL BLOCKING AS REQUIRED TO SUPPORT WALL MOUNTED DEVICES.
AT ALL SPANDREL GLASS LOCATIONS, FACE OF INTERIOR WALL TO BE CONTINUOUS
WITH ADJACENT WALL.
REFER TO A-551 FOR INTERIOR EXPANSION JOINT DETAILS.
GENERAL DIMENSIONS PROVIDED ON FLOOR PLANS AND AREA PLANS DO NOT
REFLECT THE ROUGH OPENING DIMENSIONS REQUIRED FOR COORDINATION WITH
MASONRY JOINT COURSING. CONTRACTOR IS TO PROVIDE ROUGH OPENING
FRAMING DIMENSIONS CONSISTENT WITH ENLARGED ARCHITECTURAL
PLAN/SECTION DETAILS (A5 SERIES SHEETS), AND WINDOW SCHEDULE/DETAILS (A6
SERIES). CONTRACTOR TO SUBMIT RFI FOR ANY ROUGH OPENING DIMENSIONS NOT
GIVEN IN DETAILING FOR CLARIFICATION REQUIRED.
13. ALL COLUMN FURRING TO STOP AT 6" ABOVE CEILINGS. ( TYP.)
FLOOR PLAN LEGEND
MATCH LINE
PARTITION TAG
REFER TO PARTITION SCHEDULE
BUILDING SECTION TAG
WALL SECTION TAG
EXTERIOR ELEVATION TAG
PLAN REFERENCE TAG
ROOM NAME
COLUMN GRID
DESIGNATIONS
KEYED NOTE
KEYED NOTES ONLY APPLY TO THIS SHEET
SHEET REFERENCE
H4 A-211 INTERIOR ELEVATION TAG
ROOM NUMBER
NEW DOOR
WITH DOOR TAG
REF DOOR SCHED
NEW WINDOW
WITH WINDOW MARK
REF GLAZING ELEVATIONS
A-431 A6
MATCHLINE
SEE /XX A101
A1 X
ROOM NAME
02A
1002a 28
SMOKE PARTITION
1-HOUR FIRE BARRIER
SMOKE BARRIER
2-HOUR FIRE BARRIER
3-HOUR FIRE BARRIER
A-201 A6
A-301 A6
NURSE
TRAVEL
DISTANCE
NURSE
SIGHT
LINES
100'
KEYED NOTES
NUMBER DESCRIPTION
C:\Users\tmaddy\Desktop\TEMP\117265B100A-INTERIOR-R17-CENTRAL_tmaddy-USACE_logo_USACE_RW_line-15979813.png
C:\Users\tmaddy\Desktop\TEMP\117265B100A-INTERIOR-R17-CENTRAL_tmaddy-MABPA-Turner-Construction-15979811.jpg
C:\Users\tmaddy\Desktop\TEMP\117265B100A-INTERIOR-R17-CENTRAL_tmaddy-Page_Primary_FullColor_RGB_white_background-15979809.jpg
MATTIA FLABIANO, ARCHITECT
FLORIDA REG. NO. AR0012805
THIS DOCUMENT IS RELEASED
FOR THE PURPOSE OF INTERIM
REVIEW UNDER THE AUTHORITY OF
IT IS NOT TO BE USED FOR
REGULATORY APPROVAL,
BIDDING, PERMIT, OR
CONSTRUCTION PURPOSES.
INTERIM REVIEW
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved Project Director:
VA FORM 08 - 6231
A
FULLY SPRINKLEREDU.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseDESIGN BUILD TEAM
321 4 5 6 7 8 9 10
Key Plan
Page Southerland Page, Inc.
pagethink.com
TEL
ARCHITECTURE / ENGINEERING / INTERIORS / PLANNING / CONSULTING
Austin / Dallas / Denver / Houston / San Francisco / Washington DC / International Affiliate Offices
400 W. Cesar Chavez Street Fifth Floor Austin, TX 78701 512 472 6721
512 477 3211
VA-0007-2016JAMES A. HALEY VETERANS'
HOSPITAL - NEW BED TOWER
Project Abbreviation:
13000 BRUCE B DOWNS BLVD, TAMPA, FL 33612
US ARMY CORPS OF ENGINEERS
STAMP
JAHVHNBT
135 W Central Blvd. Suite 950 Orlando, FL 32801
Turner Construction turnerconstruction.com
TEL
FAX
407 210 2500
TC 180221 | PSP 117265
CONTRACTOR:
DESIGNER:
B A
C :\U se rs
\in iti al it\
D oc um en ts \1
5B
0A
-IN
TE
R
IO
R
-R
-C E
N
TR
A L_ tm ad dy .rv t
/1 /2
:3
4:
A M
100.A-102
OVERALL FLOOR PLAN - LEVEL 02
09 OCT 2018 JC TM
65% INTERIM DESIGN
DEVELOPMENT
SCALE: 1/16" = 1'-0"F1 OVERALL PLAN LEVEL 02
16' 32'8'0-8'
Revisions: Date:
| Model |
| Layout1 |
File details come from the government source that posted it.