Attachment 8 508-26-102 Drawings Revised 4-10-2026.pdf
PDF 3 MB Posted
- Solicitation number
- 36C24726R0078
About this file
This file consists of construction documents for the U.S. Department of Veterans Affairs Building 1 Exterior Repairs and Coating Phase 1 project (Project Number 508-26-102) at the Atlanta VAMC facility. The documents include a General sheet (G001), an Overall Plan (A101), and multiple photo documentation sheets (A501 and A502) showing existing conditions as of March 5, 2026.
The project scope encompasses exterior repair and protective coating work on Building 1 at the Atlanta Veterans Affairs Medical Center. Key work areas include: cleaning, repairing, and weather sealing stucco surfaces to receive elastomeric 100% acrylic coating; applying clear waterproofing sealant to brick and concrete surfaces; and cleaning exterior metal panel faces. The documents specify that the full height of each wall is in scope unless otherwise noted. Louvers at multiple locations require carbon fiber filter coverage if work is performed or materials are stored within 100 feet. The construction documents note that all surfaces must be cleaned prior to repair or coating application. The contractor is encouraged to conduct a prebid site visit with the Contracting Officer's Representative to fully determine existing conditions, as the documents acknowledge that site conditions shown in the photos are not all-inclusive. The photos document existing cracking, mortar joint deterioration, staining, and coating conditions across various building facades that require remediation under this phase of work.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD
A/E:
STAMPCONSULTANT
7 8 9 10321 4 5 6
S F
M S
P ro je c ts
\0
-N R
M P ro je c ts
\F Y
\5
-2
-1
B u ild in g
E x te ri o r R e p a ir s P h a s e
\0
-D e s ig n \5
-2
-1
B u ild in g
E x te ri o r
F ile
.r v t
/1
/2
:4
:1
A
M
G001
GENERAL BUILDING 1 EXTERIOR REPAIRS
AND COATING PHASE 1
508-26-102
Building 1
Revisions: Date:
Construction Documents
BUILDING 1 EXTERIOR REPAIR AND COATING PHASE 1
508-26-102
Sheet List Sheet Number Sheet Name
G001 GENERAL
A101 OVERALL PLAN
A501 PHOTOS - EXISTING CONDITIONS
A502 PHOTOS - EXISTING CONDITIONS
03/05/2026
A501
A501
A501
A501
A501
NOTE 1
A
A
A
A
A
A501
A501
NOTE 1
AA
A502
A502
A502
A502
NOTE 5
NOTE 5
NOTES:
1. DENOTES PERIMETER TO BE CLEANED, REPAIRED IF NECESSARY, AND WEATHER SEALED WITH PROPER PRODUCT AS DESCRIBED BELOW AND IN THE PER THE PERFORMANCE WORK STATEMENT.
THE HIGHLIGHTED PERIMETER IS WITHIN SCOPE OF THIS PROJECT. FULL HEIGHT OF EACH WALL IS IN SCOPE, UNLESS NOTED OTHERWISE.
A. STUCCO SURFACED TO RECEIVE ELASTOMERIC 100% ACRYLIC COATING.
B. BRICK AND CONCRETE SURFACES, TO RECEIVE CLEAR WATERPROOFING SEALER
C. METAL PANELS EXTERIOR FACES TO BE CLEANED.
2. DENOTES LOCATION OF LOUVERS. LOCATIONS WITH 'X' HAVE LOUVERS ON X NUMBER OF FLOORS AT THAT LOCATION.
3. LOUVERS SHALL BE COVERED WITH CARBON FIBER FILTERS IF WORK IS BEING PERFORMED, OR MATERIALS ARE STORED WITHIN 100 FEET OF LOUVERS.
A X
4. THIS PLAN IS NOT ALL INCLUSIVE OF EXISTING CONDITIONS. CONTRACTOR IS ENCOURAGED TO MAKE A PREBID SITE VISIT WITH THE CONTRACTING OFFICER'S REPRESENTATIVE
TO FULLY DETERMINE EXISTING CONDITIONS. SEE SPECIFICATIONS FOR MORE INFORMATION.
5. DENOTES CEILING AND VERTICAL SUPPORTS OF OUTLINED SPACE IS IN SCOPE TO BE REPAIRED WITHIN SCOPE OF THIS PROJECT.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD
A/E:
STAMPCONSULTANT
7 8 9 10321 4 5 6
S F
M S
P ro je c ts
\0
-N R
M P ro je c ts
\F Y
\5
-2
-1
B u ild in g
E x te ri o r R e p a ir s P h a s e
\0
-D e s ig n \5
-2
-1
B u ild in g
E x te ri o r
F ile
.r v t
/1
/2
:4
:1
A
M
A101
OVERALL PLAN BUILDING 1 EXTERIOR REPAIRS
AND COATING PHASE 1
508-26-102
Building 1
Revisions: Date:
Construction Documents
NO SCALE
SITE PLAN ATLANTA VAMC
GENERAL NOTES
1. PHOTOS ARE MEANT TO BE A REPRESENTATION OF CONDITIONS CURRENTLY
ALONG THE EXTERIOR AS OF THE ORIGINAL DATE OF THIS SHEET.
2. PHOTOS ARE NOT ALL INCLUSIVE OF EXISTING CONDITIONS. CONTRACTOR
MAY ATTEND A PREBID SITE VISIT WITH THE CONTRACTING OFFICER
REPRESENTATIVE TO FULLY DETERMINE EXISTING CONDITONS.
3. ALL SURFACES SHALL BE CLEANED PRIOR TO REPAIR OR ELASTOMERIC
COATING OR WATERPROOFING SEALER BEING APPLIED.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD
A/E:
STAMPCONSULTANT
7 8 9 10321 4 5 6
S F
M S
P ro je c ts
\0
-N R
M P ro je c ts
\F Y
\5
-2
-1
B u ild in g
E x te ri o r R e p a ir s P h a s e
\0
-D e s ig n \5
-2
-1
B u ild in g
E x te ri o r
F ile
.r v t
/1
/2
:4
:1
A
M
A501
PHOTOS - EXISTING CONDITIONS BUILDING 1 EXTERIOR REPAIRS
AND COATING PHASE 1
508-26-102
Building 1
Revisions: Date:
NO SCALE
EXTERIOR PHOTO 1
NO SCALE
EXTERIOR PHOTO 2
NO SCALE
EXTERIOR PHOTO 3
NO SCALE
EXTERIOR PHOTO 4
NO SCALE
EXTERIOR PHOTO 5
NO SCALE
TYPICAL MORTAR JOINT CRACKING
NO SCALE
EXTERIOR PHOTO 6
NO SCALE
EXTERIOR PHOTO 7
NO SCALE
EXTERIOR PHOTO 8
NO SCALE
CRACKING SEALANT
NO SCALE
EXTERIOR PHOTO 9
NO SCALE
EXTERIOR PHOTO 10
GENERAL NOTES
1. PHOTOS ARE MEANT TO BE A REPRESENTATION OF CONDITIONS CURRENTLY
ALONG THE EXTERIOR AS OF THE ORIGINAL DATE OF THIS SHEET.
2. PHOTOS ARE NOT ALL INCLUSIVE OF EXISTING CONDITIONS. CONTRACTOR
MAY ATTEND A PREBID SITE VISIT WITH THE CONTRACTING OFFICER
REPRESENTATIVE TO FULLY DETERMINE EXISTING CONDITONS.
3. ALL SURFACES SHALL BE CLEANED PRIOR TO REPAIR OR ELASTOMERIC
COATING OR WATERPROOFING SEALER BEING APPLIED.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD
A/E:
STAMPCONSULTANT
7 8 9 10321 4 5 6
S F
M S
P ro je c ts
\0
-N R
M P ro je c ts
\F Y
\5
-2
-1
B u ild in g
E x te ri o r R e p a ir s P h a s e
\0
-D e s ig n \5
-2
-1
B u ild in g
E x te ri o r
F ile
.r v t
/1
/2
:4
:1
A
M
A502
PHOTOS - EXISTING CONDITIONS BUILDING 1 EXTERIOR REPAIRS
AND COATING PHASE 1
508-26-102
Building 1
Revisions: Date:
NO SCALE
EXTERIOR PHOTO 11
NO SCALE
EXTERIOR PHOTO 12
NO SCALE
EXTERIOR PHOTO 14
NO SCALE
EXTERIOR PHOTO 13
| Sheets |
| A101 - OVERALL PLAN |
| A501 - PHOTOS - EXISTING CONDITIONS |
| A502 - PHOTOS - EXISTING CONDITIONS |
| G001 - GENERAL |
File details come from the government source that posted it. Updated .