Revised Door_Frame_Hardware Schedule 2025 03 27.pdf
PDF 63 KB Posted
- Solicitation number
- 36C24725R0051
About this file
The document is a Door, Frame, and Hardware Schedule for a bathroom renovation project at a Veterans Affairs facility. The schedule details specific door specifications for multiple door types, including door numbers AD2-183, AD2-184, 1B188, and existing doors in rooms 7C103 and 7C106. Technical details include door width (1 3/4"), size (3'-0" x 7'-0"), material type (WD for wood), and hardware set configurations (H1 J1 S1).
The schedule includes notable remarks indicating that existing doors, frames, and hardware are to be removed, salvaged, and reinstalled between the women's and men's bathrooms (7C103 and 7C106). This aligns with the renovation project's goal of improving patient safety by reconfiguring bathroom door assemblies. The document references additional details in drawings AD107 and AE107, suggesting a comprehensive renovation plan for the bathroom spaces within the Veterans Health Administration facility.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFI 509-23-101 Plumbing questions and clarifications .docx | DOCX document | |
| 02 82 13.19 Asbestos Floor Tile and Mastic Abatement_Revised 2025 04 29.pdf | ||
| 36C24725R0051 0004.docx | DOCX document | |
| WMC Contractor Request.pdf | ||
| WMC-Form-2 Finger Printing.pdf | ||
| 36C24725R0051 0003.docx | DOCX document | |
| Amendment 001 Drawing_Bathrooms 7C - 103_06 2025 03 27.pdf | ||
| Amendment 001 2025 03 27.docx | DOCX document | |
| Amendment 001 2025 03 27_bound.pdf | ||
| RFI _ Bid Questions and Design Responses 2025 03 26 with highlighted change.docx | DOCX document | |
| 36C24725R0051 0002 1.pdf | ||
| Pictures of restrooms.pdf | ||
| 509-23-101 Bid sheet .pdf | ||
| Site Visit Sign in 4 March 2025.pdf | ||
| 36C24725R0051 0001.docx | DOCX document | |
| 36C24725R0051_1.docx | DOCX document | |
| 509-23-101 - Specifications.pdf | ||
| DD Site Plan 11x17 -082022.pdf | ||
| 509-23-101 - Drawings.pdf |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
THK WIDTH HEIGHT HEAD JAMB SILL
AD2-183 1 3/4" 3'-0" x 7'-0" 1 3/4" A WD 1 HM H1 J1 S1 N/A N/A N/A 4B AD2-184 1 3/4" 3'-0" x 7'-0" 1 3/4" A WD 1 HM H1 J1 S1 N/A N/A N/A 4B
1B188 1 3/4" 3'-0" x 7'-0" 1 3/4" A WD 1 HM H1 J1 S1 N/A N/A N/A 2 7C103 EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING H1 J1 S1 N/A N/A N/A EXISTING 1, 2 7C106 EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING H1 J1 S1 N/A N/A N/A EXISTING 1, 2
REMARKS
1 EXISTING DOORS, DOOR FRAMES AND HARDWARE TO BE REMOVED, SALAVAGED AND REINSTALLED. REFER TO DRAWINGS AD107 AND AE107.
NOTE: ALL EXISTING DOORS, FRAMES AND HARDWARE NOT SCHEDULED ARE TO REMAIN.
DOOR
EXISTING DOOR ASSEMBLIES ARE TO BE REMOVED, SALVAGE AND REINSTALLED FROM WOMEN'S BATH 7C 103 AND MEN'S BATH 7C 106 TO MEN'S BATH 7C 106 AND WOMEN'S BATH 7C 103, RESPECTIVELY. REFER TO DRAWINGS AD107 AND AE107.
TYPE MATL TYPE MATL
DETAILSSIZE
DOOR, FRAME, AND HARDWARE SCHEDULE
DOOR
NO.
FRAME
GLAZING
TYPE
FIRE
RATING
SOUND
RATING
HARDWARE
SET
REMARKS