ED-100 - ELECTRICAL - SECOND FLOOR - DEMOLITION.pdf
PDF 299 KB Posted
- Attached to
- CATH LAB Federal contract opportunity
- Solicitation number
- 36C24720B0024
About this file
This document package includes an electrical demolition drawing and details for a Cath Lab renovation project at a Veterans Affairs medical center, along with information on the related federal contract opportunity. The demolition drawing outlines the scope of work to remove existing electrical equipment, lighting, devices, and conduit in preparation for the Cath Lab upgrade. Key areas of demolition include removal of the isolated power panel, VAV unit, Liebert unit, and equipment in and serving the Cath Lab space. The federal contract opportunity is for replacement of the Cath Lab equipment with a new GE system, Stryker boom, and Cleansuite ceiling system. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration for work at the Ralph H. Johnson VA Medical Center.
View the file
Other files for this federal contract opportunity
Show all 34
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S S
S S
EP
O S
N B
WAP
EP
O
NS
NCL
PS
PS
PS
A. THE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION
PURPOSES. THE SCALE, WHEN INDICATED IS INTENDED FOR
GENERAL REFERENCE ONLY.
B. CONSTRUCTION DEBRIS SHALL BE REMOVED DAILY.
C. OPERATION OF CATH LAB 1 NOT TO BE INTERRUPTED BY
DEMOLITION. ANY ELECTRICAL CONDUIT OR WIRE SERVING
CATH LAB 2 EXISTING ABOVE CATH LAB 1 SHALL BE EXISTING
TO REMAIN.
D. ALL DEMOLITION WORK ASSOCIATED WITH EQUIPMENT
OUTSIDE OF CATH LAB 2 TO BE A PART OF PHASES 1-3.
DEMO WORK INSITE CATH LAB 2 AND DEMO OF EXISTING
ISOLATED POWER PANEL TO BE A PART OF PHASE 4
GENERAL NOTES
EXISTING FLOOR PEDESTAL TO REMAIN.
ALL LIGHTING AND CEILING DEVICES TO BE REMOVED UNLESS OTHERWISE
NOTED AS BEING RELOCATED. DEMO WIRING AS REQUIRED BACK TO
SOURCE. EXISTING WALL DEVICES TO REMAIN.
ALL EXISTING ELECTRICAL AND MECHANICAL EQUIPMENT TO BE REMOVED.
ALL ASSOCIATED WIRE AND CONDUIT IS TO BE REMOVED TO THE EXTENT
POSSIBLE. EXISTING CEILING DEVICES TO REMAIN. RELOCATED INTO NEW
CEILING AS REQUIRED. COORDINATE WITH ARCHITECTURAL DRAWINGS.
EXISTING ISO PANEL TO BE REMOVED. PULL ALL WIRES AND CONDUIT
BACK TO SOURCE AND LABEL SOURCE BREAKER AS SPARE. ALL
ASSOCIATE WIRING AND CONDUIT TO LOADS AND RECEPTACLES IN CATH
LAB TO BE DEMOLISHED. EXISTING RECEPTACLE BOXES AND JUNCTION
BOXES TO REMAIN FOR RE-USE.
EXISTING EQUIPMENT IN CONTROL ROOM TO REMAIN UNLESS OTHERWISE
NOTED.
EXISTING RECEPTACLE COVERS TO BE REPLACED WITH GFI TYPE.
NO WORK IN THIS AREA UNLESS OTHERWISE NOTED. SEE PANEL
SCHEDULES AND RISER DIAGRAM FOR ADDITIONAL INFORMATION.
ALL CONDUIT IN CATH LAB WALL TO REMAIN. REUSE AS NEEDED TO
SERVE NEW LOADS. REPLACE RECEPTACLE COVERS WITH NEW.
CONDUIT THAT EXTENDS OVER EXISTING CATH LAB 1 THAT WOULD
INTERFERE WITH FUNCTION OF THIS AREA IS TO BE ABANDONED RATHER
THAN DEMOLISHED.
EXISTING LEIBERT UNIT TO BE REMOVED, INCLUDING ALL WIRE AND
CONDUIT TO CONDENSOR UNIT ON ROOF ABOVE. COORDINATE WITH
MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
EXISTING VAV ABOVE CEILING TO BE REMOVED. WIRE AND CONDUIT BACK
TO SOURCE AND LABEL CIRCUIT AS SPARE. CONSTRUCTION CONTRACTOR
SHALL COORDINATE WITH COR FOR TRACING CIRCUITS. CONTRACTOR
SHALL TRACE CIRCUITS WHILE VA IS PRESENT.
EXISTING CONDUITS IN WALLS AND ABOVE CEILINGS IN THESE AREAS ARE
TO BE RELOCATED AS REQUIRED TO ACCOMODATE NEW WORK.
DEMOLITION KEYED NOTES
DRAWINGS. SEE SCHEDULE FOR TYPE (*).
CEILING OR WALL MOUNTED EXIT SIGN. PROVIDE NUMBER OF FACES AND CHEVRONS AS INDICATED ON
LED LIGHTING FIXTURE, CEILING OR WALL MOUNTED,
LED LIGHTING WALLWASH FIXTURE, CEILING MOUNTED.
CONNECTED TO NORMAL POWER. SEE SCHEDULE FOR TYPE (*). SEE ARCHITECTURAL RCP FOR EXACT*
LOCATION AND CEILING TYPE. SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH.
SEE SCHEDULE FOR TYPE (*).*
HALF-SHADED INDICATES CONNECTED TO LIFE SAFETY BRANCH.* * *
LUMINAIRE, CEILING MOUNTED, CONNECTED TO THE NORMAL POWER SYSTEM (UNLESS OTHERWISE NOTED).
SEE SCHEDULE FOR TYPE (*). SEE ARCHITECTURAL RCP FOR EXACT LOCATION AND CEILING TYPE.
SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH. HALF-SHADED INDICATES CONNECTED TO THE EMERGENCY OR LIFE SAFETY BRANCH; VIA EMERGENCY GENERATOR SET OR BATTERY BALLAST, SEE PLANS.
LED LIGHTING FIXTURE, WALL MOUNTED OR UNDER CABINET, CONNECTED TO NORMAL POWER.
SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH. SEE SCHEDULE FOR TYPE (*).
SINGLE POLE SWITCH, MOUNTED 42" AFF TO CENTER OF DEVICE.S
EMERGENCY LIGHTING FIXTURE, CEILING-MOUNTED OR WALL-MOUNTED AT 7'-6" AFF UNLESS NOTED
OTHERWISE. CONNECT UNSWITCHED.
DUPLEX RECEPTACLE, MOUNTED 18" AFF TO CENTER OF DEVICE. NEMA 5-20R UNLESS OTHERWISE
TWO DUPLEX RECEPTACLES IN 2-GANG BOX, MOUNTED 42" AFF TO CENTER OF OUTLET
OR 2" FROM BOTTOM OF OUTLET TO TOP OF BACKSPLASH OR COUNTERTOP. SLASH INDICATES
OUTLET TO TOP OF BACKSPLASH OR COUNTERTOP. SLASH INDICATES CONNECTED TO THE EMERGENCY
DUPLEX RECEPTACLE, MOUNTED 42" AFF TO CENTER OF OUTLET OR 2" FROM BOTTOM OF
TWO DUPLEX RECEPTACLES IN 2-GANG BOX, MOUNTED 18" AFF TO CENTER OF DEVICE. SLASH
INDICATED. SLASH INDICATES CONNECTED TO THE EMERGENCY POWER SYSTEM.
INDICATES CONNECTED TO THE EMERGENCY POWER SYSTEM.
POWER SYSTEM.
CONNECTED TO THE EMERGENCY POWER SYSTEM.
JUNCTION OR PULL BOX. W = WEATHERPROOF.J
FUSED SAFETY SWITCH. NUMERAL INDICATES FUSE RATING.15
PANELBOARD SURFACE MOUNTED.
PANELBOARD FLUSH MOUNTED.
PUSHPAD. PROVIDE BOX AND CONDUIT AS REQUIRED. COORDINATE WITH HARDWARE VENDOR.PP
CARD READER. PROVIDE BOX AND CONDUIT AS REQUIRED. COORDINATE WITH HARDWARE VENDOR.CR
EMERGENCY SYSTEM OFF PUSH BUTTONEPO
DD FIRE ALARM DUCT MOUNTED SMOKE DETECTOR.
SYMBOLS LEGEND
RL = EXISTING DEVICE TO BE RELOCATED.
DASHED SYMBOLS INDICATE EXISTING DEVICES.
RLD = RELOCATED DEVICE SHOWN IN FINAL LOCATION.
RM = EXISTING DEVICE TO REMAIN.
RM
RM
RV = EXISTING DEVICE TO BE REMOVED.
RP = EXISTING DEVICE TO BE REPLACED WITH NEW DEVICE.
EX = EXISTING DEVICE
PROJECT LOCATION:
CARDIAC CATH LAB (2ND FLOOR)
BEE STREET
MAIN HOSPITAL ENTRANCE
BEE STREET/BRAVO STREET
MENTAL HEALTH CLINIC ENTRANCE
N
KEY PLAN
14.513.512.511.510.59.57.46.1
AA
BB
CC
A
A.8
B.8
C
B
ATS LS
ATS LL
SWBD HDCC
SWBD HDLS
MDP
CRIT ISO PANEL #1
POWER LINE FILTER
SWBD 2HEDP1
ATS EE
RM
RM
RM RM
RMRM RM
RM
RM
RV
RM
RM
RM
RM
RM
RP RP RM
RMRP
RL
RL
RL
RL
RL
RL
RV RV
RV RV
RV RV
RV
RV RV
RV
RV
RV
RV
RV
RV RV
RV RV
RV
RV
RM
RM
PANEL A PANEL CCB
PANEL HA
PANEL LSA
PANEL HCCC
PANEL 2LE-AA231PANEL 2HE-AA231
CRIT ISO PANEL #2
RM
7 7
RM
SMOKE TIGHT WALL (EXISTING)
1-HR FIRE RATED WALL (EXISTING)
2-HR FIRE RATED WALL (EXISTING)
WALL RATING LEGEND
LEAD-LINED WALL (EXISTING - MAINTAIN & PATCH AS NEEDED IN RENOVATION)
5838 Monroe Road, Suite 100 Charlotte, NC 28212
704 531 3000 Firm License Number: F-0674
Project No. 4415
Charlotte Engineers, LLP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% - CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT GMK Associates, Inc.
1201 Main Street, Suite 2100 Columbia, SC 29201 803-256-0000 Megan C. Day, AIA
STAMPPROGRAM MANAGER
321 4 5 6 7 8 9 10
Odell International 129 Fast Lane, Suite 200 Mooresville, NC 28117 704-401-2040 C. Harmon Reed, Jr. AIA
CONSULTANT
Charlotte Engineers 5838 Monroe Road Charlotte, NC 28212 704-531-3000 Michael Eaves
D :\l oc al re vi t m od el s\
\4
- C
E C en tra l M od el .rv t 8/
/2
:4
5:
P M
ED-100
ELECTRICAL - SECOND FLOOR - DEMOLITION CATH LAB SITE PREP at
RALPH JOHNSON VAMC
109 BEE STREET CHARLESTON, SC
534-CSI-555
MAY 08, 2020 CLH JCE
1/8" = 1'-0"1 ELECTRICAL - FIRST FLOOR - DEMOLITION
Revisions: Date:
ADDENDUM 2 08/12/2020
| Sheets |
| ED-100 - ELECTRICAL - SECOND FLOOR - DEMOLITION |
| EP-201 - ELECTRICAL - SECOND FLOOR - POWER & SYSTEMS |
File details come from the government source that posted it. Updated .