36C24718R0116-00003001.pdf
PDF 21 KB Posted
- Attached to
- 509-326 Construct Community Living Center Federal contract opportunity
- Solicitation number
- 36C24718R0116
About this file
36C24718R0116 00003 087100_Amendment 00002 RFI 7 RESPONSE.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24718C0191-000.docx | DOCX document | |
| 36C24718R0116-00007000.docx | DOCX document | |
| 36C24718R0116-00006000.docx | DOCX document | |
| 36C24718R0116-00006001.pdf | ||
| 36C24718R0116-00005001.pdf | ||
| 36C24718R0116-00005000.docx | DOCX document | |
| 36C24718R0116-00004000.docx | DOCX document | |
| 36C24718R0116-00003000.docx | DOCX document | |
| 36C24718R0116-00002002.pdf | ||
| 36C24718R0116-00002000.docx | DOCX document | |
| 36C24718R0116-00002001.pdf | ||
| 36C24718R0116-00002003.pdf | ||
| 36C24718R0116-00002004.pdf | ||
| 36C24718R0116-00001000.docx | DOCX document | |
| 36C24718R0116-001.docx | DOCX document | |
| 36C24718R0116-000.docx | DOCX document |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
01-01-16
08 71 00-1
SECTION 08 71 00
RESPONSE TO RFI #7
CHARLIE NORWOOD VA, AUGUSTA, GA
20 MARCH 2018
HW-1
Each Door to Have: NON-RATED
1 Continuous Hinge
1 Door Pull w/ Plate J401 x J302
1 Push Plate J302
1 Kick Plate J102
1 Mop Plate (@ Inswing Doors) J103
1 Closer C02011/C02021
1 Floor Stop L02121 x 3 FASTENERS
3 Silencers L03011
HW-2
Each Door to Have: RATED/NON-RATED
Hinges QUANTITY & TYPE AS REQUIRED
1 Keyed Privacy Indicator Lock F13 x OCCUPANCY INDICATOR
1 Closer C02011/C02021
1 Kick Plate J102
1 Mop Plate (@ Inswing Doors) J103
1 Floor Stop L02121 x 3 FASTENERS
1 Set Self-Adhesive Seals R0Y154
STONE THRESHOLD BY OTHER TRADES.
08 71 00-2
HW-4G
Each Door to Have: RATED/NON-RATED
1 Utility Lock F09
1 Closer (@ Rated Doors) C02011/C02021
1 Kick Plate J102
1 Floor Stop L02121 x 3 FASTENERS
HW-10C
Each Pair to Have: NON-RATED
2 Continuous Hinges x INTEGRAL HINGE GUARD CHANNEL
X ADJUSTA-SCREWS
1 Set Auto Flush Bolts TYPE 25 LESS BOTTOM BOLT
1 Utility Lock F09
1 Overlapping Astragal with R0Y634 x R0Y154 x THRU-BOLTS
Self-Adhesive Seal
2 Kick Plates J102
1 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
2 Floor Stops L02121 x 3 FASTENERS
08 71 00-3
HW-10J
Each [ADO] Pair to Have: RATED/NON-RATED
1 Continuous Transfer Hinge x INTEGRAL HINGE GUARD CHANNEL
X ADJUSTA-SCREWS x 8-THRUWIRE
TRANSFER X IN-HINGE ACCESS PANEL
1 Continuous Transfer Hinge x INTEGRAL HINGE GUARD CHANNEL
X ADJUSTA-SCREWS x 4-THRUWIRE
TRANSFER X IN-HINGE ACCESS PANEL
1 Set Auto Flush Bolts TYPE 25 LESS BOTTOM BOLT
1 Classroom Hospital Lock F08 x PADDLES POINTING DOWN
1 Electric Unlatch Strike E09321 (FAIL-SECURE)
1 Power Supply REGULATED, FILTERED, 24VDC, AMPERAGE
AS REQUIRED
1 Coordinator TYPE 21A
1 Overlapping Astragal with R0Y634 x R0Y154 x THRU-BOLTS
Self-Adhesive Seal
2 Armor Plates J101 x 1.275 MM (0.050 INCH) THICKNESS
2 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
2 Overhead Stops C01541-ADJUSTABLE
1 Set Self-Adhesive Seals R0Y154
AUTOMATIC DOOR OPERATORS AND CONTROLS BY SECTION 08 71 13, AUTOMATIC DOOR
OPERATORS.
POWER TRANSFERS SHARED BY ELECTRIC STRIKE AND RE-ACTIVATION SENSOR WIRING
(RE-ACTIVATION SENSORS PROVIDED BY SECTION 08 71 13).
*AT WOOD PAIRS RATED 45-MINUTES OR MORE, PROVIDE ELECTRIC STRIKE 310-2-3/4
(FOLGER ADAM OR EQUAL) IN LIEU OF SPECIFIC UNLATCH STRIKE.
08 71 00-4
HW-12E
Each Pair to Have: RATED
2 Continuous Hinges x INTEGRAL HINGE GUARD CHANNEL
X HOSPITAL TIP X ADJUSTA-SCREWS
1 Exit Device TYPE 7 or 8 F01
1 Exit Device TYPE 7 or 8 F08 LEVER
1 Key Cylinder TYPE AS REQUIRED
1 Set Meeting Stile Astragals R0Y834
2 Closers C02011/C02021
2 Kick Plates J102
2 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
2 Floor Stops L02121 x 3 FASTENERS
2 Door Bottom R0Y434 x NYLON BRUSH INSERT
2 Set Self-Adhesive Seals R0Y154
08 71 00-5
HW-R2C
Each Door to Have: NON-RATED
1 Door Pull w/Plate J401 x J302
1 Push Plate J302
1 Kick Plate J102
1 Mop Plate (@ Inswing Doors) J103
1 Closer C02011/C02021
1 Floor Stop L02121 x 3 FASTENERS
1 Threshold J32300 x 57 MM WIDTH (2-1/4 INCHES)
1 Auto Door Bottom R0Y346 – HEAVY DUTY
2 Sets Self-Adhesive Seals R0Y154
HW-SH-3D
Each [AC, EL, REX, DPS] Door to Have: RATED
1 Continuous Hinge x INTEGRAL HINGE GUARD CHANNEL
X ADJUSTA-SCREWS X 4-THRUWIRE
TRANSFER X IN-HINGE ACCESS PANEL
1 Electrified Lock F07 (E01-REX, E06) 24VDC
1 Power Supply REGULATED, FILTERED, 24VDC, AMPERAGE
AS REQUIRED
1 Closer C02011/C02021
1 Armor Plate J101 x 1.275 MM (0.050 INCH) THICKNESS
1 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
1 Threshold J32300 x 57 MM WIDTH (2-1/4 INCHES)
1 Auto Door Bottom R0Y346 – HEAVY DUTY
2 Sets Self-Adhesive Seals R0Y154
1 Alarm Contact
120VAC POWER, CONDUIT, AND WIRING BY DIVISION 26.
CARD READER BY DIVISION 28.
08 71 00-6
HW-SH-3G
Each [AC, RR, EL, REX, DPS] Door to Have: RATED
1 Continuous Transfer Hinge x INTEGRAL HINGE GUARD CHANNEL
X ADJUSTA-SCREWS x 4-THRUWIRE TRANSFER x
IN-HINGE ACCESS PANEL
1 Electrified Lock F13-MOD x RIGID OUTSIDE LEVER X NO INSIDE
TURN X KEY RETRACTS LATCHBOLT AND
DEADBOLT (E01-REX, E06) 24VDC
1 Power Supply REGULATED, FILTERED, 24VDC, AMPERAGE
AS REQUIRED
1 Closer C02011/C02021
1 Armor Plate J101 x 1.275 MM (0.050 INCH) THICKNESS
1 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
1 Floor Stop L02121 x 3 FASTENERS
1 Threshold J32300 x 57 MM WIDTH (2-1/4 INCHES)
1 Auto Door Bottom R0Y346 – HEAVY DUTY
1 Set Self-Adhesive Seals R0Y154
1 Alarm Contact
120VAC POWER, CONDUIT, AND WIRING BY DIVISION 26.
CARD READER BY DIVISION 28.
08 71 00-7
HW-SH-9A
Each [PB] Pair to Have: RATED
2 Continuous Hinge x INTEGRAL HINGE GUARD CHANNEL
X ADJUSTA-SCREWS
1 Set Auto Flush Bolts TYPE 25
1 Dust Proof Strike L04021
1 Push-button Combination Lock N3 – A156.13 F07 G1 E06
1 Coordinator TYPE 21A
1 Overlapping Astragal with R0Y634 x R0Y154 x THRU-BOLTS
Self-Adhesive Seal
2 Closers C02011/C02021
2 Armor Plates J101 x 1.275 MM (0.050 INCH) THICKNESS
2 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
2 Floor Stops L02121 x 3 FASTENERS
- - - E N D - - -