Bldg 4 2nd Floor Plan.pdf
PDF 262 KB Posted
- Solicitation number
- 36C24622B0035
About this file
This solicitation seeks to replace an obsolete police security camera system at the FNCVAMC facility. The contractor shall develop a complete plan to replace all existing system components, including up to 1000 feet of CAT6 cable, 200 feet of new A conduit, and 20 four by four junction boxes. The replacement system must include a rack mounted UPS to support the system for a minimum of one hour. It must meet all VA requirements and offer at least two viable alternatives with descriptions of features, warranty coverage, and overall functions. The existing system consists of 156 interior and exterior cameras, three network video recorders, 27 PoE switches, two core switches, and various operator workstations and display monitors. The contractor must have pre-work photographs and replace any damaged ceiling tiles.
View the file
Other files
Show 40 more
Latest 50 of 51 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
9'-1034"
'-5
1 4"
2'-11"
DN
8'-81 2"
6'- 71 2"
9'-1178"9'-934"
'-1
13 4"
9'-1134"
3'- 17 8"
8'-678"9'-111 8"
3'- 17 8"
3'-1"
4'-
5 8"
3'- 1"
6'- 21 2"
6'- 4"
9'-7 7 16"
ROOFROOF
6'-334"
3'-01 2"
3'
7'-3"
3'-1"
3'-5"
3'- 5"
9'-91 2"
'-1
11 2"
4'
4"
3'- 61 4"
3'-51 2"
4" 9"
3'- 13 4"
3'-3" 3'-
6"
9'-10"
'-1
11 4"
2'-9"
3'- 2"
4'-1"
1'
10"
3'- 61 2"
9'-2"
5'- 7"
'-2
1 2"
4'-8"
3'- 91 2"6"
1'-534"
4'- 43 8"
3'-101 2" 1' 3'-6"
2" 7"
8'-31 4"
8'-61 2"
3'- 2"
2'-10" 1'-4"
3'- 21 4"
2"
7'-9"
'-7
7'-11" 2'-10" 1'
1' 3'-9"
6"4" 7'-101
4"
'-1
11 4"
3'-11 2"
3'- 51 2"
3'- 1"
2'-9"
2'-81 2"4"
4'
2"
834"
3'- 53 4"
6'- 83 4"
3'- 31 4"
3'
1'-7"
3'-1"
3'
3'-1"
3'- 03 4"3'-1"
3'- 21 4"
934" 3'-6 9
16"
3'- 73 4"
3'- 3"
3'-2"
9" 3" 9'-10"
'-1
11 2"
4'
2"
'-1
11 2"
8"
4"9'-101
2"
3'- 61 4"
3'-51 2"
3'-1"
3'- 13 4"
2" 2"3'-
1"
3'-1"3'- 51 2"
3'-6"2"
4'
5" 4"
1'-111 4"
934"
3'-2"
3'- 31 2"
2'-
9'-101 4"
6'- 71 8"
2'-
3'-21 4"
1'-81 2"
3'- 31 2"
7'-3"3'- 11 4"
9"
2'-11"31 2"
9'-111 4"
'-1
13 4"
16'-41 2"
'-1
13 4"
2'-10"
5'
1'-21 4" 2'-61
2" 2'-
1 2"7'-334"
3'-9" 3'-9"
3'- 51 2"
3'- 51 2"
9'- 9"
2'-91 4" 41
2" 9'-978"
1'
3'- 5"
6" 81 2"
20'-10 9 16"
1134"
'-2
1 4"
20'-5 7 16"
1134"
68'-8"
1134" 20'-10 9
16"
'-2
1 4"
20'-058" 1134"
69'-013 16"
CLOSET
206A
STORAGE
207A
STORAGE
208A
HAC
209 STORAGE
213A
STORAGE
215A
STORAGE
216A
STORAGE
217A
CLOSET
202A
CLOSET
203A
CLOSET
205A
CORRIDOR
OFFICE
OFFICE
OFFICE
WOMEN'S
TOILET
MEN'S
TOILET
KITCHEN
STAIR
OFFICE
UNISEX
TOILET
213B
UNISEX
TOILET
215B
OFFICE
OFFICE
OFFICE
LOGISTICS
OFFICE
217UNISEX
TOILET
219B
UNISEX
TOILET
218B
OFFICE
LIVING
APPLICATIONS
201UNISEX
TOILET
202B
CLOSET
201A
OFFICE
202OFFICE
UNISEX
TOILET
205B
UNISEX
TOILET
203B
INSPECTOR
GENERAL
OFFICE
File details come from the government source that posted it. Updated .