36C24620R0007-0006006.pdf
PDF Posted
- Attached to
- Inpatient Privacy Renovate 5B
- Solicitation number
- 36C24620R0007
About this file
This is a presolicitation notice for an inpatient privacy renovation project at the Durham VA Medical Center. The Department of Veterans Affairs is seeking a contractor to renovate approximately 8,000 square feet of space on the fifth floor into twelve new private patient rooms and ancillary spaces. The estimated construction value is between $1,000,000 and $5,000,000. The solicitation is anticipated as a total service-disabled veteran owned small business set-aside under NAICS Code 236220 with a size standard of $36.5 million. Interested vendors should register on the website as the solicitation and any amendments will be posted there. Proposals will be due approximately 45 days after issuance of the solicitation, which is targeted for November 7, 2019. Any questions must be emailed to the point of contact listed.
36C24620R0007 0006 08-TK,_FA_100_BD.1.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24620R0007-0011001.pdf | ||
| 36C24620R0007-0011002.pdf | ||
| 36C24620R0007-0011000.docx | DOCX document | |
| 36C24620R0007-0010000.docx | DOCX document | |
| 36C24620R0007-0009000.docx | DOCX document | |
| 36C24620R0007-0008001.pdf | ||
| 36C24620R0007-0008000.docx | DOCX document | |
| 36C24620R0007-0007000.docx | DOCX document | |
| 36C24620R0007-0006004.pdf | ||
| 36C24620R0007-0006000.docx | DOCX document | |
| 36C24620R0007-0006003.pdf | ||
| 36C24620R0007-0006005.pdf | ||
| 36C24620R0007-0006001.pdf | ||
| 36C24620R0007-0006002.pdf | ||
| 36C24620R0007-0005000.docx | DOCX document | |
| 36C24620R0007-0005001.pdf | ||
| 36C24620R0007-0005005.pdf | ||
| 36C24620R0007-0005004.pdf | ||
| 36C24620R0007-0005002.pdf | ||
| 36C24620R0007-0005003.pdf | ||
| 36C24620R0007-0004000.docx | DOCX document | |
| 36C24620R0007-0003000.docx | DOCX document | |
| 36C24620R0007-0003001.pdf | ||
| 36C24620R0007-0002002.pdf | ||
| 36C24620R0007-0002001.docx | DOCX document | |
| 36C24620R0007-0001001.pdf | ||
| 36C24620R0007-023.pdf | ||
| 36C24620R0007-022.docx | DOCX document |
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADO AUTOMATIC DOOR OPERATOR
AFF ABOVE FINISH FLOOR
CCTV CLOSED CIRCUIT TELEVISION
COAX COAXIAL CABLE
COMM COMMUNICATION
COR CONTRACTING OFFICER
REPRESENTATIVE
DC DOOR CONTACT SWITCH
DN DOWN
DO DOOR OPERATOR
DVR DIGITAL VIDEO RECORDER
EEB EMERGENCY EXIT BUTTON
EL ELECTRICAL STRIKE
FA FIRE ALARM
FAP FIRE ALARM PANEL
FAAP FIRE ALARM ANNUNCIATOR PANEL
FO FIBER OPTIC
IT INTERCOMMUNICATION ROOM
MATV MASTER ANTENNA TELEVISION
MM MULTI MODE FIBER
NAC NETWORK APPLIANCES CONTROL PANEL
NS NO SCALE
NTS NOT TO SCALE
NVR NETWORK VIDEO RECORDER
TECHNOLOGY ABBREVIATIONS LIST
OC ON CENTER
OIT OFFICE OF INFORMATION TECHNOLOGY
PACS PHYSICAL ACCESS CONTROL SYSTEM
PAMN PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEM
PB PUSH BUTTON
PDU RACK POWER DISTRIBUTION UNITS
POE POWER OVER ETHERNET
PR PAIR
RX REQUEST TO EXIT
SEP SERVICE ENTRANCE PROTECTION
SM SINGLE MODE FIBER
TEL TELEPHONE
TGB TELECOMM GROUND BUS BAR
TM TELEMONITORING
TMGB TELECOMM MAIN GROUND BUS BAR
TP TWISTED PAIR
TR TELECOMM ROOM
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
WM WIRE MANAGEMENT
WAP WIRELESS ACCESS POINT
UL UNDERWRITERS LABORATORY
UPS UNINTERRUPTIBLE POWER SUPPLY
UTP UNSHIELDED TWISTED PAIR
GENERAL TECHNOLOGY NOTES
1. PROVIDE COMMUNICATIONS DEVICES AND EQUIPMENT IN ACCORDANCE WITH THE CONTRACT
DOCUMENTS, MANUFACTURER'S RECOMMENDED PROCEDURES, ALL APPLICABLE LOCAL AND
STATE CODES, AMERICANS WITH DISABILITIES ACT, LATEST EDITION OF THE NATIONAL
ELECTRICAL CODE, BICSI STANDARDS, AND VA STANDARDS.
2. PROVIDE ADDITIONAL SUPPORT FOR DEVICES AND EQUIPMENT WHERE BUILDING
CONSTRUCTION IS NOT SUITABLE FOR DIRECT MOUNTING.
3. FIRESTOP, DRAFTSTOP, SMOKESTOP OR PROTECT ANNULAR SPACE AROUND PENETRATIONS
THROUGH WALLS, PARTITIONS, FLOORS, CEILINGS, AND ROOF IN ACCORDANCE WITH
REQUIREMENTS OF NFPA 70, UL LISTING REQUIREMENT AND APPLICABLE BUILDING CODES.
4. PROVIDE CABLING THAT COMPLIES WITH LATEST EDITION OF TELECOMMUNICATIONS
DISTRIBUTION METHOD MANUAL AND ANSI/TIA/EIA PUBLICATIONS.
5. COMPLY WITH LATEST EDITION OF ANSI/TIA/EIA 758 AND 607B OR 607A - GROUNDING AND
BONDING REQUIREMENTS FOR TELECOMMUNICATIONS IN COMMERCIAL BUILDING.
6. COMPLY WITH LATEST EDITION OF ANSI/TIA/EIA 568B - COMMERCIAL BUILDING
TELECOMMUNICATIONS WIRING STANDARD.
7. COMPLY WITH LATEST EDITION OF ANSI/TIA/EIA 569B - COMMERCIAL BUILDING STANDARD FOR
TELECOMMUNICATIONS PATHWAYS AND SPACES.
8. COMPLY WITH LATEST EDITION OF NFPA 70 NATIONAL ELECTRICAL CODE.
9. COMPLY WITH LATEST EDITION OF NFPA 99 HEALTHCARE FACILITIES CODE.
10. COMPLY WITH LATEST EDITION OF NFPA 101 LIFE SAFETY CODE.
11. COORDINATE WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION.
12. MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE PURPOSES, TO
INDICATE A QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A PARTICULAR
MANUFACTURER. PRODUCTS DEEMED EQUAL AND APPROVED BY THE COR WILL BE
ACCEPTABLE. COMPLY WITH "BUY AMERICAN ACT".
13. MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, BOXES, OUTLET, OR EQUIPMENT
UNLESS NOTED OTHERWISE.
14. PROVIDE RGS OR EMT CONDUIT UNLESS OTHERWISE NOTED.
15. PROVIDE MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT LABEL LISTED BY APPROVED
THIRD PARTY TESTING AGENCY.
16. NOTIFY COR REGARDING DISCREPANCY BETWEEN PLANS AND SPECIFICATIONS FOR
CLARIFICATION. THE MORE STRINGENT OF THE THEM SHALL TAKE PRECEDENCE.
17. FOR LOCATION (CORRIDOR, ROOM OR ADJACENT SPACE) WITH TWO OR MORE VISIBLE FIRE ALARM NOTIFICATION APPLIANCES WITHIN THE FIELD OF VIEW, PROGRAM VISIBLE TO FLASH IN
SYNCHRONIZATION.
18. PROVIDE TIA/EIA CAT 6 COPPER OUTLETS AND CONNECTORS.
19. ALL WORK AREA OUTLETS SHALL BE 8 PIN, CAT 6 KEYSTONE JACK WIRED PER T568A OR T568B
AS DIRECTED BY THE VA COR.
20. LABEL DEVICES IN ACCORDANCE WITH LATEST ANSI/TIA 606A OR 606B EDITION AS WELL AS THE
STANDARDS SET FORTH BY THE VA HOSPITAL OIT.
21. PROVIDE A MINIMUM OF 12" CLEARANCE ABOVE THE CABLE TRAY PER TIA/EIA 569.B PARAGRAPH 4.5.6.2.
22. VA WILL CONDUCT A WIRELESS ACCESS POINT SURVEY AND PROVIDE THE SURVEY TO THE
CONTRACTOR. INSTALL CABLING AND EQUIPMENT IN ACCORDANCE WITH THE SURVEY.
COORDINATE WITH COR/OIT.
23. ALL CABLING INSTALLED ABOVE CEILING SHALL BE PLENUM RATED.
TECHNOLOGY SYMBOL LEGEND
DATA OUTLET - 2-4 PR UTP
DATA OUTLET - 1-4 PR UTP
TELCO OUTLET - 1-4 PR UTP
SYMBOL HEIGHT DESCRIPTION
18"
18"
48"
ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.
ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.
SEE DRAWINGS FOR MORE INFORMATION.
NOTE: NOT ALL SYMBOLS ARE USED.
ELECTRONIC LOCKING MECHANISM
DOOR CONTACT
REQUEST FOR EXIT SENSOR
CARD READER
(K - KEYPAD)
48"CR
ES
DC
RX
48" EMERGENCY EXIT BUTTON TO RELEASE DOOR (EEB)
WIRELESS ACCESS POINT - 2-4 PR UTP
WALL PHONE-1-4W
N
S NURSE CALL PATIENT STATION WITH PILLOW SPEAKER (GET WELL)
(1 - SINGLE, 2 - DUAL, V - VANDAL RESISTANT)
P
NURSE CALL PATIENT BED INTERFACE RECEPTACLE
B
NURSE CALL CODE BLUE STATION
E NURSE CALL EMERGENCY STATION WITH PULL CORD AND AUDIO +40" AFF IN
RESTROOM, +72" AFF IN SHOWER (V - VANDAL RESISTANT, PB - PUSH BUTTON)
D
NURSE CALL DUTY STATION
M
NURSE CALL MASTER STATION/CONSOLE
NURSE CALL DOME LIGHT
(Z - ZONE LIGHT, V - VANDAL RESISTANT)
IC
INTERCOM WITH CAMERA
IC
INTERCOM MASTER WITH PUSH TO RELEASE DOORM
NURSE CALL WIRELESS ANTENNAS / RTLSNW
DATA OUTLET - 4-4 PR UTP18"
TV OUTLET WALL MOUNTED, 1-4 PR UTP, 1-RG6
48"
54"
DESK
CCTV DOME CAMERA FIXED
CCTV DOME CAMERA PAN/TILT/ZOOM
FOUR POST OIT EQUIPMENT RACK
OIT EQUIPMENT CABINET
NURSE CALL EQUIPMENT CABINET
MATV EQUIPMENT CABINET
CCTV EQUIPMENT CABINET
NCE
MATV
CCTV
LADDER CABLE TARY
FLOOR BOX FOR DATA
AS NOTED
DOOR
DOOR
ABOVE
DOOR
HEADWALL
18"
HEADWALL
/40"
40",72"
18"
60"
CEILING
CEILING
6' TO TOP
6' TO TOP
FLOOR
PHYSICAL ACCESS CONTROL SYSTEMPACS 6' TO TOP
ELECTRONIC PANIC HARDWAREEP
DO
DOOR OPERATOR
HANDWAVE
T
C
NURSE CALL STAFF TERMINAL
NURSE CALL PATIENT STATION WITH CALL CORD.
(1 - SINGLE, 2 - DUAL, V - VANDAL RESISTANT)
48"
HEADWALL
W WIRELESS PENDANT
L
KP PATIENT ROAM ALERT ACCESS CONTROL KEYPAD48"
PATIENT ROAM ALERT ANTENNACEILING
GROUND BUS
CEILING
DOOR
DOOR
48"
ABOVE
DOOR
NURSE CALL DOME LIGHT
FLOOR
FLOOR
FLOOR
ABOVE
CEILING
18"
4'x8'x3/4" FIRE RATED TTB8"
DATA OUTLET - 6-4 PR UTP18"6
N
M
PATIENT STATION (PB - PUSH BUTTON, M - MICROPHONE, K -KEYED)
88" MOTION DETECTOR
MD
FLOOR TWO POST OIT EQUIPMENT RACK
CEILING MOUNTED SPEAKERSCEILING
WALL MOUNTED SPEAKERS96"
S
S
AREA OF REFUGE PANEL6' TO TOP
AREA OF REFUGE ANNUNCIATION PANEL6' TO TOP
AOF
AOFA
IC AREA OF REFUGE INTERCOM48"
AREA OF REFUGE STROBE LIGHTCEILINGSL
DP
DPP
DURESS PANIC ALARM PUSH BUTTON48"
DURESS PANIC ALARM PANEL6' TO TOP
N
ANTENNA (REFERENCE SHEET KEY NOTES)CEILING
RTLS VIRTUAL WALL (BATTERY POWERED INFRARED DEVICECEILING
RTLS MONITOR (BATTERY POWERED INFRARED DEVICE)CEILING
RTLS 900 MHz SECURITY CONTROLLER (POE)CEILINGSTAR
M
VW
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:5
P
M
TK001
TECHNOLOGY GENERAL INFORMATION
1 9RSB JDM
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 06/28/2019
BID DOCUMENTS
558-18-15018-048 kgenther Model
ELEVATOR
SS S
S
S
S
S S S
4 4 4
S
LI
M
IT
O
F P
R O
JE
C
T S
C O
P E
L L
M M
N N
P P
Q Q
R R
R.1 R.1
5.1
5.1
8 9
13 14
14 15
SS
TT
# SHEET KEY NOTES:
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:5
P
M
TD101
FIFTH FLOOR TECHNOLOGY
DEMOLITION PLAN
2 9RSB JDM
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 06/28/2019
BID DOCUMENTS
558-18-15018-048
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
Scale: 1/8" = 1'-0"
FIFTH FLOOR TECHNOLOGY DEMOLITION PLAN 0 4 8 16
NORTH
TRUE
A. REMOVE ALL DEVICES, CONDUIT, AND
WIRE BACK TO SOURCE.
B. ALL EXISTING CONDITIONS, CONDUIT, AND
DEVICES ARE BASED ON BEST AVAILABLE
INFORMATION AT TIME OF ENGINEERING
SURVEY AND VISUAL INSPECTION. VERIFY
EXISTING CONDITIONS.
C. TURN ALL EQUIPMENT (CAMERAS, WAP,
ETC.) TO COR.
E
E E
E
E E
E
SS
E
EE
E
E
D
D
D
M
D
M
2 4
2 4
4 2
66"
66" 66"
66"
N 1
N 1 N 1 N 1
N 1
N 1
N 1
N 1
N 1 N 1
N 1 N 1
60"
E
E
EE
E
E E
E
E
E
E E
DD
D
DD
P P
2 2 2 2
D
4 4 4
NW
NW
NWNWNW NW NW
DD
S P S
P
S P
S P
S P S P
S P
S P
S P
S P
60"
60"
60"
60"
2 60
2 2
W W
N 2
4 4
LI
M
IT
O
F P
R O
JE
C
T S
C O
P E
PATIENT RM
B5008
CARE STATION
B5009
PATIENT RM
B5010
PATIENT RM
B5011
PATIENT RM, BARIATRIC
B5012
LOCKER
B5014
PATIENT RM
B5016
SOILED UTILITY
B5018
STAFF LOUNGE
B5015
CLEAN SUPPLY
B5019
ALCOVE
B5020
PATIENT RM
B5021
PATIENT RM
B5022 PATIENT RM
B5024
PATIENT RM
B5025
PASSAGE
B5041
NOUR
B5026
MEDS
B5027
BATH
B5007A
CORRIDOR
B5040
BATH
B5008A
BATH
B5010A
BATH
B5011A
BATH
B5016A
BATH
B5024A
BATH
B5025A
BATH
B5021A
BATH
B5022A
STAIR
B5050
STAFF TLT
B5014A
PATIENT RM, ISOLATION
B5028
BATH
B5028A
ANTE
B5028B
PATIENT RM, ISOLATION
B5029
BATH
B5029A
ANTE
B5029B
PATIENT RM, BARIATRIC
B5007
CARE STATION
B5005
EQUIP
B5004
BATH
B5012A
CARE STATION
B5013
CARE STATION
B5023
NURSE MGR OFFICE
B5030
EQUIP
B5017
TEAM WORK ROOM
B5031
ELEC
B5017A
OIT
B5003A
TK101
L L
M M
N N
P P
Q Q
R R
R.1 R.1
5.1
5.1
8 9
13 14
14 15
SS
TT
05 05
050505
0404 04 04
1 1 22
11 06
13 13 13 13 13
151415151514
BIO
B5003
M
N
P
R R
R.1 R.1
5.1
5.1
8 9
SS
TT
# SHEET KEY NOTES:
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/1
/2
:3
:2
A
M
TK101
FIFTH FLOOR TECHNOLOGY PLAN
3 9RSB JDM
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 06/28/2019
BID DOCUMENTS
558-18-15018-048
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
Scale: 1/8" = 1'-0"
FIFTH FLOOR TECHNOLOGY PLAN
01 PROVIDE 3-4" FIRE/SMOKE UL LISTED SLEEVE
ASSEMBLY.
02 PROVIDE NEW IT FLOOR HINGED EQUIPMENT
RACK.
03 PROVIDE LADDER TRAY.
04 PATIENT WIRELESS ACCESS POINT
LOCATIONS.
05 INTERFACE TV WITH PATIENT NURSE CALL AND
BED.
06 NURSE CALL EQUIPMENT.
07 PACS EQUIPMENT. MOUNT BELOW NURSE
CALL CABINET.
08 PROVIDE 3/4" FIRE RETARDANT PLYWOOD
WITH TGB.
09 SEE SHEET GC101 FOR WORK SCOPE RELATED
TO ALTERNATE 1.
10 (TYP) PROVIDE 2-4 PR UTP TO THE TELEMETRY
SYSTEM IN EACH PATIENT ROOM, TERMINATE
ON PATCH PANELS IN THE BIOMED ROOM.
TYPICAL OF ALL PATIENT ROOMS.
11 PROVIDE 2-4 PR UTP FOR THE TELEMETRY
MONITORING SYSTEM AND TERMINATE ON
PATCH PANELS IN THE BIOMED ROOM. THE
OTHER 2-4 PR UTP ARE FOR IT. TERMINATE ON
PATCH PANEL IN OIT ROOM.
12 LOCATION OF EXISTING MATV PANEL.
13 (TYP) PENDANT TELEMETRY ANTENNA.
PROVIDE 3-4 PR UTP TO EACH ANTENNA &
TERMINATE ON PATCH PANEL IN NEW BIOMED
ROOM.
14 PROVIDE 3-4 PR UTP FOR FUTURE RTLS,
TERMINAL ON PATCH PANELS IN BIO MED RM.
LABEL ETLS. CABLE COLOR TO BE
COORDINATED WITH COR/IT.
15 PROVIDE 4 PR UTP FOR MEDS TUG ROBOT
(PHARMACY) AND TERMINATE IN BIO MED
ROOM. LABEL PHARMACY. COLOR TO BE
COORDINATED WITH COR/IT.
16 PATIENT WIRELESS CABLE TO BE RUN TO THIS
LOCATION. PROVIDE 15FT. SLACK, COIL
CABLES AND SUPPORT FROM CEILING.
17 PROVIDE FLOOR HINGED EQUIPMENT RACK
FOR BIO MED QUIPMENT.
18 PROVIDE WALL MOUNTED 24 PORT FIBER
OPTIC PATCH PANEL.
19 PROVIDE NEW TGB.
Scale: 1/2" = 1'-0"
OIT B5004A ENLARGEMENT
Scale: 1/8" = 1'-0"
FIFTH FLOOR TECHNOLOGY PLAN ALTERNATE DEDUCT 1 0 4 8 16
NORTH
TRUE
0 2 4 8
NORTH
TRUE
PROVIDE (2)
4" SLEEVE
ASSEMBLIES
A. COORDINATE PATIENT HEADWALL
TECHNOLOGY CONNECTIONS WITH DEVICE
MANUFACTURER AND COR.
B. TELEMETRY ANTENNA LOCATIONS SHALL BE
FIELD VERIFIED BY THE MANUFACTURERS.
COORDINATE WITH VA VENDOR.
C. COORDINATE CABLE TRAY WITH ALL TRADES
ON THE JOB SITE.
D. PROVIDE 20 FOOT LOOP FOR WIRELES
ACCESS POINTS.
E. SEE HEADWALL DETAIL ON TK502 AND QH102.
0 4 8 16
NORTH
TRUE
AETHON ROBOT DOOR INTERCONNECTIONS REVISION 08/15/2019
N
R
A
N
046636
E
E N
I
G
H
K
I
A
W
O
N
A
T
R
F
SEAL
R
P
O
O
I
SS
O E
H
RC
A
I
L
A
N
L
E
N
C
I
M
H
E
A
L
S
CRCRCRCRCR CR
CR
CR CRDC
DC
DC
DC
DCDC
DC DC
ESES
ES
ES
ES
ES
ES ES
CR
RX RX RX
RX RX
RXRX
RX RX
ESDC
RX
ESDC
RK
RK
RK
L
L
L
ELRX DC
CR
CR
EL
RX
EL
LI
M
IT
O
F P
R O
JE
C
T S
C O
P E
PATIENT RM
B5008
CARE STATION
B5009
PATIENT RM
B5010
PATIENT RM
B5011
PATIENT RM, BARIATRIC
B5012
LOCKER
B5014
PATIENT RM
B5016
SOILED UTILITY
B5018
STAFF LOUNGE
B5015
CLEAN SUPPLY
B5019
ALCOVE
B5020
PATIENT RM
B5021
PATIENT RM
B5022 PATIENT RM
B5024
PATIENT RM
B5025
PASSAGE
B5041
NOUR
B5026
MEDS
B5027
BATH
B5007A
CORRIDOR
B5040
BATH
B5008A
BATH
B5010A
BATH
B5011A
BATH
B5016A
BATH
B5024A
BATH
B5025A
BATH
B5021A
BATH
B5022A
STAIR
B5050
STAFF TLT
B5014A
PATIENT RM, ISOLATION
B5028
BATH
B5028A
ANTE
B5028B
PATIENT RM, ISOLATION
B5029
BATH
B5029A
ANTE
B5029B
PATIENT RM, BARIATRIC
B5007
CARE STATION
B5005
EQUIP
B5004
BATH
B5012A
CARE STATION
B5013
CARE STATION
B5023
NURSE MGR OFFICE
B5030
EQUIP
B5017
TEAM WORK ROOM
B5031
OIT
B5003A k
L L
M M
N N
P P
Q Q
R R
R.1 R.1
5.1
5.1
8 9
11 12
13 14 15
S
T
0202 02
VW
VW
VW
VW
VW
VW
VW
VW
VW
VW
VW
VW
VW
VW
VW
VW
VW
VW
VW
VW
VW
VW
VW
VW
V W
V W
V W
V W
V W
V W
V W
V W
M
MM
M
M
M M
M
MM
M
M M M
M
M
VW VW
STARSTAR
STAR
K
VW VW
R R
R.1 R.1
5.1
5.1
8 9
S
T
SOILED UTILITY
B5018
CLEAN SUPPLY
B5019
ALCOVE
B5020
NOUR
B5026
MEDS
B5027 BATH
B5028A
EQUIP
B5017
N
P
9 10
ELECTRICAL CLOSET
B6011
# SHEET KEY NOTES:
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:0
P
M
TK102
FIFTH FLOOR SYSTEMS PLAN
4 9RSB JDM
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 06/28/2019
BID DOCUMENTS
558-18-15018-048
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
Scale: 1/8" = 1'-0"
FIFTH FLOOR SECURITY PLAN
0 4 8 16
NORTH
TRUE
01 SEE SHEET GC101 FOR WORK SCOPE
RELATED TO ALTERNATE DEDUCT 1.
02 (TYP) CABLE TRAY AS INDICATED ON TK101.
03 CAT 5/6 POE DROP LOCATION.
04 PHARMACY PENDANT ANTENNA. PROVIDE 1-4
PR UTP TO EACH ANTENNA & TERMINATE ON
PATCH PANEL IN NEW BIOMED ROOM.
05 PROVIDE (3)RUNS OF 4 PR UTP TO IT ROOM.
LABEL RTLS_CABLING.
06 LOCKDOWN SWITCH
07 LOCATION OF EXISITNG ROAMING DATA
SWITCH. SEE DETAIL 2 ON TK503 FOR MORE
INFO.
08 ELECTRICAL ROOM B6011 CONTAINING
EXISTING ROAMING DATA SWITCH. LOCATED
ON FLOOR ABOVE IN THIS LOCATION.
REFERENCE VIEW 3 THIS SHEET.
09 INTERLOCK AETHON ROBOT SYSTEM WITH
THE PACS DOORS. AS THIS WILL HELP THE
ROBOT OPEN THE DOORS.
A. TELEMETRY ANTENNA LOCATIONS SHALL BE
FIELD VERIFIED BY THE MANUFACTURERS.
COORDINATE WITH VA VENDOR.
B. FIELD VERIFY PHARMACY ANTENNAS WITH THE
VA VENDOR.
Scale: 1/8" = 1'-0"
FIFTH FLOOR SECURITY PLAN
0 4 8 16
NORTH
TRUE
Scale: 1/4" = 1'-0"
SIXTH FLOOR ROOM B6011 0 4 8 16
NORTH
TRUE
OFFICE
OFFICE
ORTHOPEDIC
ORTHOPEDIC
SGY SGY
OFFICE
OFFICE OFFICE
OFFICE
STORAGE
OFFICE
OFFICE
WORK RM
BIOHAZARD
SOILED UTILITY
WORKER
NURSING
SVC CO-ORDR
MEN
STORAGE
OFFICERESP CARE
CHIEFCHIEF PULM
OFFICEOFFICEOFFICEOFFICE
CLEAN SUPPLYRESP CARE OFFICE
RESP CARE PATIENT
EDUCATION EXERCISE
TESTING
RESP CARE
LOCKERS
LOCKERPULM SECYOFFICE
OFFICE
PATIENT ROOM
PATIENT RM
WOMENS
FAMILY/WAITING
CONSULTATION
CALL RM
UTILITY
SOILED
MICU
ELECTRICAL
MEDICATION
CLOSET
OFFICE HOME
STORAGE
EQUIPMENT
EXAM / TREATMENT
STAFF OFFICE
OFFICE
DUMB WAITER
SURG RISK
ASSESSMENT NURSE WORK RM
CHIEF
PLASTIC
SURGY
NEURO SURGY
ADMIN OFFICER
CHIEF SURG SVC
OFFICE
OFFICE
OFFICE CONFERENCE RM
BATH RM URODYNAMICS
CYTOSCOPY
CHECK-IN
KEEPING
EXAM
SUPPLY
WOMENS
MALE
PATIENT RM
OFFICE
ANESTHESIOLOGY
LINEN
SOILED
UTILITY
OFFICE
BATH RM
WAITING AREA
CHIEF
ANESTHESIOLOGY
ENT/CARDIOTHORACIL
PGM SUPPORT
RESIDENCY PROGR
LOCKER
MENS LOCKER
STORAGE
CHIEF
GENERAL SURGY
OFFICE
OFFICE
CHIEF
OTOLARYNGOLOGY
OFFICE
OFFICE
CHIEF UROLOGY
WOMENS
MALE
KEEPING
STORAGE
KEEPING
ELEVATOR
ELEVATOR
KEEPING
ORTHOPEDIC
PATIENT ROOM
HOUSE
HOUSE
HOUSE
STAIR-3
DUMB WAITER
CONFERENCE RM
SHAFT
FIRE PROTECTION CLOSET
FIRE PROTECTION CLOSET
STAIR-2
NEUROLOGY
HOUSE KEEPING
TELEPHONE
C5001A-1
HOUSE
KEEPING
GENERAL
STORAGE
IRM CLOSET
CLEAN LINEN
8-BED ICU
7-BED ISOLATION
6-BED ICU
1-BED ICU
STAFF LOUNGE
MICU
ROOM
MEN
FIRE PROTECTION
STORAGE
CLOSET
CLOSET FIRE
PROTECTION
CLOSET
MECH RM
STORAGE
FIRE PROTECTION CLOSET
STAIR-4
STORAGE
FIRE PROTECTION CLOSET
STAIR-5
ANEST
EDUCATION LAB
MULTI PURPOSE
RM
ANTE RM
ANTE RM
DUMB WAITER ELEVATOR ELEVATOR
ELEVATOR ELEVATOR
OFFICE
PATIENT RM
PATIENT RM
2-BED ISOLATION
ANESTHESIOLOGYANESTHESIOLOGYANESTHESIOLOGY
OFFICE OFFICE OFFICE
EQUIPMENT STORAGE
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
STORAGE
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
OFFICE CUBICLES
SURG
OFFICE
4-BED
WOMENS
STAFF
ANESTHESIOLOGY
SOCIAL
PHYSICIANS
CLOSET
PATIENT RM MICU
5-BED ICU
PATIENT RM
4-BED ICU
PATIENT RM
3-BED MICU
UTILITY
STORAGE
PULM
OXYGEN CO-ORDR
UROLOGY
OFFICE ANESTHESIOLOGY
OFFICE
ANESTHESIOLOGY
OFFICE
ANESTHESIOLOGY
OFFICE
EXAM EXAM
EXAM /
CHECK-IN
EXAM EXAM
EXAM EXAM
EXAM
GENERAL
GENERAL
CLEAN
FIRE
RM
BREAK
GENERAL
STORAGE
GENERAL
TOILET TOILET
VESTIBULE
VESTIBULE
EQUIPMENT
BEDS &
CLOSET
OIT
OFFICE
OFFICE
GENERAL
STORAGE
GENERAL
STORAGE
GENERAL
TOILET STORAGE
GENERAL
STORAGE
EQUIPMENT
UTILITY
SOILED
BED
EXAM / TREATMENT
STORAGE
EQUIPMENT
EXAM
BREAK
CLEAN
NURSES
STATION
B5029
LINEN CHUTE
D5008
B5002
A5002A
C5008
C5006
C5004
C5002
C5026
C5032
C5034
C5036
C5046
C5044
C5020
C5018
C5016
C5017
C5019
C5021
C5023
C5025
C5027
C5015 C5009
C5011
C5029 C5050
D5013
D5007
D5014
D5011
D 5028
D5024
D5021
D5019 D5017
D5020
D5018
D5015
D5022
D5005
D5003
D5001
D5012
D5010
D5002
D5000
C5001
C5003
A5018 A5010
A5020
A5017
A5015
A5009
A5005A5001
A5002 A5006 A5024 A5026 A5028 A 5030
A5021
A5016
A5014A
A5014C
A5014B
A5014D
A5023
A5032
A5040
A5027
A5029
A5025
A5035
A5037
A5039
A5050
A5052A
A5052
A5054
A5056
A5058
A5031
D5026
D A5033
A5007
A5007AC5013
D5023
D5016A
A5002B
D5015A
D5015B
A5003
D5013A
C
B A
C5010A
A5008 A5000
A5004A A5022
A5019
A5011 A5013
A5048 A5046 A5044 A5042A
A5034
A5036
A5038
A5012
C5012
D5016 D5004D5006
D5019A
C5030
C5048
A5004B
C5010
5009A
A5043
A5034A
A5042
A5058A A5058B
C5043A
C5046A
C5046A C5044A
D5017C
D5022B D5022A
D5019B D5017B D5017A
D5005A
D5003B D5001AD5001B
D5004B D5002BD5008B D5006B
D5010A
C5019A
C5022
C5014A
D5003A
D5021A
TOILET
C5046B
TOILET
C5048A
C5028
C5014
A5001A
C5000
C5009A
A5016
A5021A
A5041 A5041A
TUBE SYSTEM
LI
M
IT
O
F P
R O
JE
C
T S
C O
P E
PATIENT RM
B5008
CARE STATION
B5009
PATIENT RM
B5010
PATIENT RM
B5011
PATIENT RM, BARIATRIC
B5012
LOCKER
B5014
PATIENT RM
B5016
SOILED UTILITY
B5018
STAFF LOUNGE
B5015
CLEAN SUPPLY
B5019
ALCOVE
B5020
PATIENT RM
B5021
PATIENT RM
B5022
PATIENT RM
B5024
PATIENT RM
B5025
PASSAGE
B5041
NOUR
B5026
MEDS
B5027
BATH
B5007A
CORRIDOR
B5040
BATH
B5008A
BATH
B5010A
BATH
B5011A
BATH
B5016A
BATH
B5024A
BATH
B5025A
BATH
B5021A
BATH
B5022A
STAIR
B5050
STAFF TLT
B5014A
PATIENT RM, ISOLATION
B5028
BATH
B5028A
ANTE
B5028B
PATIENT RM, ISOLATION
B5029
BATH
B5029A
ANTE
B5029B
PATIENT RM, BARIATRIC
B5007
CARE STATION
B5005
EQUIP
B5004
BATH
B5012A
CARE STATION
B5013 ?
CARE STATION
B5023
NURSE MGR OFFICE
B5030
EQUIP
B5017
TEAM WORK ROOM
B5031
OIT
B5003A
L
M
N
P
Q
R
R.1
5.1
5.1
8 9
13 14 15
SS
TT
# SHEET KEY NOTES:
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:0
P
M
TK103
FIFTH FLOOR OVERALL SYSTEMS PLAN
5 9RSB JDM
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 06/28/2019
BID DOCUMENTS
558-18-15018-048
Scale: 1/16" = 1'-0"
FIFTH FLOOR OVERALL TECHNOLOGY PLAN
01 3-4" FIRE/SMOKE UL LISTED SLEEVE
ASSEMBLY. SEE TK101.
02 TECHNOLOGY FEEDER FOR NEW IT ROOM. 24
MM 50 MICRON TIGHT BUFFERED ARMORED
OM4 FIBER AND 25 PR TELECOM CABLE FROM
NEW 5B IT ROOM TO MAIN SERVER ROOM
FG104.
03 PROVIDE 4" FIRE/SMOKE UL LISTED SLEEVE
ASSEMBLY.
04 LOCATION OF EXISTING NURSE CALL
INTERFACE. COORDINATE CONNECTION TO
EXISTING NURSE CALL SYSTEM WITH SITE
BIOMEDICAL AND COR.
05 NURSE CALL INTERFACE CABLING. RUN 2-4PR
UTP AND 1-4 STRAND FIBER OPTIC (OM4)
CABLE. COORDINATE CONNECTION TO
EXISTING NURSE CALL SYSTEM WITH SITE
BIOMEDICAL AND COR.
06 NEW NURSE CALL EQUIPMENT CABINET.
COORDINATE WITH COR AND BIOMED.
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
0 8 16 32
NORTH
TRUE
FG144A
EG017A
GENERAL
LAB
STORAGE
TO CRAWL
SPACE
TO CRAWL
RAMP
RAMP
BG000
BG001
AG002A
AG000A
AG002
CG008
S4
S5 P3
P2
P1 P7
P6
P5
AG005
AG009
AG011AG012
AG009A
AG008
AG015A
AG015B
AG003
CG009
CG007
CG010
BG003
FG145
FG146A
EG006
EG013
EG015
EG017
EG007
EG011
EG009
EG018
EG010
EG014
EG012
EG008
EG004
EG005
EG002
EG003
FG156
FG155
FG154
FG143
FG137A
FG147FG146 FG147A
FG142
FG148
FG149
FG157
FG158
FG104
FG160
FG160A
FG159
AG017
AG015
AG010
EG005A
EG007A
EG001
FG43
FG141
FG104A
FG156A
FG151
BG001A
AG001
EG003A EG003B
EG012A
EG018A
EG017A
FG1000
CG003
ROLLING
SHUTTER
UP
DN
STAIR-1
CANTEEN STORAGE
OFFICE
MORGUE
OFFICE
FREEZER
OFFICE
VENDING RM
KEEPING
CPR EQUIP
CANTEEN CANTEEN
OFFICE
FREEZER
STAIR-12
FIRE PROTECTION
HOUSE
ELECTRICAL RM
TELEPHONE
CLOSET
ISO OFFICE
KEEPING
OFFICE
LAB
OFFICE
OFFICE
OFFICE
STORAGE
STORAGE
STORAGE
RESEARCH
AFGE
AFGE
DECEDENT
AFFAIRS OFFICE ISO OFFICE
IRM OFFICE
CLOSET TOILET
SERVER RM
TELECOM
TELECOM
OFFICE
CLOSET
ELEVATOR
ELECTRICAL
HOUSE
LAB
FIRE PROTECTION
STORAGE
IRM OFFICE
STORAGE
CANTEEN
STAIR-10
HAC
DUMB WAITER
DUMB WAITER
GREEN
ELEVATOR
GREEN
ELEVATOR
GREEN
ELEVATOR
OFFICE
DUMB WAITER
FIRE PROTECTION
FIRE
CANTEEN
STORAGE
LINEN
CHUTE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
ELEVATOR
CAFETERIA
CAFETERIA
LINEN
CHUTE LINEN
CHUTE
SHAFT
MENS TOILET
TRASH RM
FEMALE TOILET
FEMALE TOILET
CORRIDOR
CORRIDOR
CORRIDOR
RETAIL STORE
MECH
RETAIL STORE
RECORDS RM
OFFICE, PRIVACY
CANTEEN DINING
CANTEEN DINING
CANTEEN DINING
KITCHEN
CANTEEN DINING
OFFICE
CORRIDOR
OFFICE, NURSING UNION ISO OFFICE
CORRIDOR
CORRIDOR
MECH RM
CORRIDOR
CORRIDOR
ELECTRICAL
ELECTRICAL
PROTECTION
446. 3969
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
# SHEET KEY NOTES:
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:0
P
M
TK104
GROUND FLOOR TECHNOLOGY
ROUTING PLAN
6 9RSB JDM
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 06/28/2019
BID DOCUMENTS
558-18-15018-048
Scale: 3/32" = 1'-0"
GROUND FLOOR TECHNOLOGY ROUTING PLAN
01 PROVIDE 4" FIRE/SMOKE UL LISTED SLEEVE
ASSEMBLY.
02 EXISTING SERVER ROOM. PROVIDE 24 PORT
FIBER PATCH PANEL WITH COUPLERS.
COORDINATE LOCATION WITH COR.
03 NEW FIBER TO 5TH FLOOR.
04 NEW 24 MM 50 MICRON TIGHT BUFFERED
ARMORED FIBER (OM4) AND 25 PR TELECOM
CABLE FIBER FROM NEW 5B IT ROOM TO MAIN
SERVER ROOM FG104 ON GROUND FLOOR.
05 TERMINATE COPPER ON 110 BLOCK.
COORDINATE WITH COR.
1/2" THREADED
SUPPORT RODS
@ 48" O.C.
C-CLAMP TO
BLOCKING
CABLE RUNWAY SB-17
SEE PLAN FOR
LOCATION
+8'-0"
+9'-6"
1/2' THREADED
SUPPORT RODS
@ 48" O.C.
C-CLAMP TO
BLOCKING
CABLE RUNWAY
SB-17 SEE PLAN
FOR LOCATION
C-CLAMP
NUT
MIN. 3" EMBEDMENT
BOLT TO CEILING JOIST
(PROVIDE BLOCKING AS
NECESSARY)
48" MAX. CABLE TRAY WIDTH
CABLE RUNWAY
EXTENSION
CLAMP
CABLE
RUNWAY
RUNWAY END
SUPPORT (SB-163)
AUXILLARY
STRINGER TUBE OR
CABLE RUNWAY
"C" CLAMP
AND HANGER
@ 4'-0" O.C.
CORNER
BRACKET
CABLE RUNWAY
FINISHED FLOOR
CR
ES DC
RX
NOTE:
1. ELECTRICAL CONTRACTOR SHALL
PROVIDE CONDUIT, BOXES, AND
SUPPORTS. COORDINATE AND VERIFY
LOCATIONS WITH OWNER.
2. PROVIDE CABLING PER
MANUFACTURER'S RECOMMENDATION.
ELECTRONIC LOCKING
MECHANISM
3/4" C
FINISHED CEILING
8"x8"x4" HINGED
CONTROLLER BOX
MOUNTED ABOVE CEILING
1" C
TO ACCESS CONTROL
SYSTEM PANEL (PACS),
VERIFY LOCATION
CARD READER IN SINGLE
GANG BOX, OR AS REQUIRED
BY MANUFACTURER, FACING
TOWARDS UNSECURED SIDE
OF DOOR
REQUEST FOR EXIT
SENSOR(S), FACING
TOWARDS SECURED SIDE OF
DOOR
EL
1/2" C3/4" C
ELECTRONICALLY
OPERATED LATCH
STRIKE
DOOR CONTACT
3/4" C
EEB
PACS
CONTROLLER
PACS
POWER
SUPPLY
PACS
CONTROLLER
PACS
POWER
SUPPLY
J
PACS 8"x8"x6' HINGED TROUGH
8'x8'x3/4" FIRE RATED PLYWOOD
PACS 6"x6"x6'
HINGED VERTICAL
TROUGH
FIRE ALARM
ADDRESSABLE
RELAY OUTPUT
MODULE
1" CONDUIT FROM
EACH PACS DOOR
1" CONDUIT FROM
EACH PACS DOOR
NOTE:
1.CONTRACTOR SHALL COORDINATE SYSTEM
PROGRAMMING AND FINAL CONNECTION
WITH.
20A, 110V, (1) 4S-JBOX
16" AFF IN CENTER OF
PLYWOOD
TO ROAMING
SYSTEM (2/TK503)
ROBOT
INTERLOCK W/
AETHON ROBOT
TO OPEN
DOORS.
18" CABLE LADDER
CORNER SUPPORT
NOTE:
SCHEMATIC SAMPLE LADDER SYSTEM
SB-163
SB-162
3/8" x 1-1/2"
RUNWAY
STRINGER
(1) 4 PR UTP
DATA CABLE, YELOW,
GREEN OR GRAY
(1) 4 PR UTP
TELEPHONE
CABLE, WHITE
1/2" HIGH BLACK LETTERS ON
CLEAR BACKGROUND,
PANDUIT OR EQUAL ON
PERMANENT LABEL, TYPICAL.
XXX
XXX
B B
T T
BLANK
SINGLE GANG COVER
PLATE WITH 6 OUTLETS
(TYPICAL). LOCATIONS AS
SHOWN ON PLANS
TELE/DATA (TYP.) ( 4)
BLANK
(1) 4 PR UTP
TELEPHONE
CABLE, WHITE
1/2" HIGH BLACK LETTERS ON
CLEAR BACKGROUND,
PANDUIT OR EQUAL ON
PERMANENT LABEL, TYPICAL.
XXX
XXX
B B
T B
BLANK
SINGLE GANG
COVER PLATE WITH
6 OUTLETS
(TYPICAL).
LOCATIONS AS
SHOWN ON PLANS
TELE/DATA (TYP.) ( 2)
(1) 4 PR UTP
TELEPHONE
CABLE, WHITE
C C
(1) 4 PR UTP
DATA CABLE, BLUE
C C
(1) 4 PR UTP
DATA CABLE, YELLOW,
GREEN OR GRAY
(1) 4 PR UTP
DATA CABLE, YELLOW,
GREEN OR GREY
BLANK
NOTE: ALL EQUIPMENT AND INSTALLATION SHALL
BE APPROVED BY VAMC IT DEPARTMENT.
BLANK
XXX
XXX
B B
T
TELEPHONE (TYP.) ( T)
BLANK
BB
B
WHITE (TO TELEPHONE
CABINET IN IT ROOM)
BLANK
NOTES:
1. ALL CONNECTIONS TO THE TMGB AND TGB SHALL BE MADE WITH
COMPRESSION STYLE LONG BARREL CONNECTORS ON THE
CONDUCTOR AND 2-LUG BOLTED CONNECTIONS TO THE
GROUNDING BARS. CONNECTIONS TO STEEL SHALL BE WITH
SILICON BRONZE HARDWARE. CONNECTION TO SLEEVES OR
CONDUITS SHALL BE BY AN APPROVED GROUNDING BUSHING.
2. LOCATE TMGB AND TGB ON THE LEFT OF THE TTB AND 16" AFF.
3. ALL CONDUCTORS USED FOR GROUNDING SHALL BE MARKED AT
CONNECTION POINT AND EVERY TEN FEET (10') THEREAFTER
WITH A LABEL IDENTIFYING IT AS THE TELECOMMUNICATIONS
GROUNDING BACKBONE (TBB). USE PANDUIT #LTYK OR
APPROVED EQUIVALENT.
4. PROVIDE 4"H x 20"L x 1/4"W TMGB.
5. PROVIDE 2"H x 24"L x 1/4"W TGB.
6. CONTRACTOR SHALL CLEAN THE BUS BAR AND APPLY ANTI-
OXIDANT PRIOR TO FASTENING THE CONNECTORS TO THE BUS
BAR.
7. ALL COPPER BACKBONE CABLING SHALL MEET THE
REQUIREMENTS OF TIA/EIA 568-C FOR RISER CABLE.
C O
M M
E
Q U
IP
M
E N
T /R
A C
K S
M E
T A
L S
L E
E V
E S
(W
IT
H
IN
C O
M M
R
M
S T
R U
C T
U R
A L S
T E
E L
B A
S K
E T
T R
A Y
G R
O U
N D
L O
O P
MAIN
TMGB
TR-#1
TGB
COMM. EQUIPMENT/RACKS
ELECTRICAL PANEL
STRUCTURAL STEEL
CABLE TRAY
TR-#2
TGB
COMM. EQUIPMENT/RACKS
ELECTRICAL PANEL
STRUCTURAL STEEL
CABLE TRAY
PROVIDE 6 AWG
CONDUCTOR, EACH
RUN
PROVIDE 1/0 AWG CONDUCTOR
TO TGB FOR EACH TR
PROVIDE 2/0 AWG CONDUCTOR
TO GROUND RING FOR
ELECTRICAL SYSTEM
PROVIDE 1/0 AWG
CONDUCTOR TO
TGB FOR EACH TR
E L E
C T
R
IC
A L P
A N
E L
FINISHED FLOOR
MOUNTING HEIGHT AS
SHOWN IN DRAWINGS
4-11/16" SQ. BY 2-1/2"
DEEP BOX WITH SINGLE
GANG 5/8" TILE RING.
1-1/4" CONDUIT WITH
COMMUNICATIONS WIRING
WALL
CORRIDORROOM
6"
NYLON BUSHING
COORDINATE WITH DUCTWORK
EXTEND CONDUIT TO ABOVE
FINISHED ACCESSABLE
CEILING IN CORRIDOR TO
CABLE TRAY UNLESS NOTED
OTHERWISE.
SUSPENDED LAY-IN
CEILING
CABLE TRAY
(SECURE) CLINICAL PATIENT
WIRELESS ACCESS POINT
SURFACE BISCUIT, GREEN CABLE,
GREEN JACK (TO OIT). CABLE
SHALL BE RUN IN CONDUIT WITH
MINIMUM SIZE OF 3/4".
(UNSECURE) PATIENT
WIRELESS ACCESS POINT
SURFACE BISCUIT, ORANGE
CABLE, ORANGE JACK (TO BIO
MED). CABLE SHALL BE RUN
IN THE CABLE TRAY.
NOTE: CABLE COLOR SHALL BE ORANGE
10"
4"
1/4"
3/16" DIAMETER, TYP. FOR 6
1/4" DIAMETER, TYP. FOR 12
TMGB & TGB
1 TELECOM ROOM OPPER GOUND BAR, 1/4" x 4" x 10", CHATSWORTH PRODUCTS
INC. NO. 10622-010 OR APPROVED EQUAL BY ERICO OR HARGER GOUNDING
PRODUCTS. HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION.
STANDOFF BRACKET ASSEMBLY WITH INSULATORS, TYP. FOR 2.
LOCK WASHER, TYPICAL FOR 2.
ANCHOR BOLTS, TYPICAL FOR 2.
A CONTINUOUS #3/0 GREEN INSULATED CONDUCTOR SHALL BE RUN
FROM SERVICE GROUND AT MAIN SWITCHBOARD (MSB) TO MAIN TELECOM
ROOM GROUND BAR (TMGB).
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:1
P
M
TK501
TECHNOLOGY DETAILS
7 9RSB JDM
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 06/28/2019
BID DOCUMENTS
558-18-15018-048
Scale: N.T.S.
CABLE LADDER - ELEVATION
Scale: N.T.S.
CABLE LADDER - PLAN VIEW
Scale: N.T.S.
SINGLE DOOR CARD ACCESS - STANDARD HARDWARE
Scale: N.T.S.
DOOR CONTROLLER ELEVATION
Scale: N.T.S.
CABLE LADDER CORNER
Scale: N.T.S.
CABLE RUNWAY RADIUS DRIP DETAIL
Scale: N.T.S.
CABLE LADDER - VERTICAL LADDER
Scale: N.T.S.
TELECOMMUNICATIONS FACEPLATE
Scale: N.T.S.
TELECOMMUNICATIONS GROUNDING
Scale: N.T.S.
TELECOMMUNICATIONS OUTLET INSTALLATION
Scale: N.T.S.
WIRELESS ACCESS POINTS
Scale: 3/16" = 1'-0"
TELECOM & MAIN ELECTRICAL GROUND BAR
FIFTH FLOOR
NEW IT
RACK
RM B5003A
NEW 24 STRAND MULTIMODE 50
MICRON TIGHT BUFFERED
ARMORED FIBER (OM4) AND
NEW 1-25 PR CAT5E CABLE
FOURTH FLOOR
THIRD FLOOR
SECOND FLOOR
FIRST FLOOR
GROUND FLOOR
NEW 24 PORT WALL MOUNTED
FIBER OPTIC PATCH PANEL.
NEW CORE AND SLEEVE.
SEAL AFTER WORK IS DONE.
TYPICAL EACH FLOOR.
PROVIDE NEW 24 PORT
FIBER PATCH PANEL WITH
4-6 PORT COUPLERS AND
110 BLOCKS FOR NEW 25
PR TELECOM CABLE.
COORDINATE WITH COR.
SERVER ROOM
FG104
TO TELECOM
GROUNDING BUS
TO OIT ROOM, 12 STRAND MM
FIBER (OM4) 4-4 PR UTP
24 PORT P.O.E.
SWITCH(ES)
WIRE MANAGEMENT
WIRE MANAGEMENT
FIBER OPTIC
PATCH PANEL
SPACE
COPPER PATCH
PANEL(S)
WIRE MANAGEMENT
UPS/BATTERY
TO SECURITY
OFFICE (VERIFY
LOCATION)
STANDARD FIXED
WALL OR DOME
CAMERA (TYPICAL)
NOTE:
1. CCTV CABINET SHALL BE WALL MOUNTED HINGED 18 U'S,
26"Wx30"Dx36"H. FRONT GLASS DOOR. QUIET FAN WITH
FILTER. POWERSTRIP SURGE PROTECTION WITH FILTER.
GROUND BUS BAR, SHELVES.
2. ALL CABLING SHALL BE IN A MINIMUM 3/4" CONDUIT.
3. CCTV CABLE COLOR SHALL BE VIOLET.
4. 4 PR UTP IN CONDUIT (<295')
5. FIBER IN CONDUIT (>295')
20A, 120V
FINISHED FLOOR
TYPICAL DATA RACK DETAIL NOTES:
1. 24 PORT FIBER OPTIC WALL MOUNTED PATCH
PANEL WITH COUPLERS.
2. HORIZONTAL WIRE MANAGEMENT (1U).
3. 48 PORT COPPER PATCH PANEL, DATA.
4. UNINTERRUPTIBLE POWER SUPPLY (3000 VA).
5. POWER RECEPTACLE, SEE ELECTRICAL
DRAWINGS.
6. 48 PORT COPPER PATCH PANEL, DATA.
7. NEW FLOOR HINGED EQUIPMENT CABINET
WITH POWER STRIP, AC POWER LINE SURGE
PROTECTOR AND FILTER, GROUND BUS,
GROUND TERMINAL, AND VERTICAL &
HORIZONTAL WIRE MANAGEMENT.
8. VERTICAL POWER STRIP.
9. VERTICAL GROUND BUS.
10. VERTICAL WIRE MANAGEMENT, IF RACKS
ARE GANGABLE THEN PROVIDEONLY ONE
VERTICAL WIRE MANAGEMENT BETWEEN
THEM.
11. 48 PORT COPPER PATCH PANEL FOR WAP.
12. SPACE FOR VA FURNISHED EQUIPMENT.
13. FIBER OPTIC PATCH CORDS
22"
10 10
2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48
1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8
2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48
1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8
2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48
1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8
2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48
1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8
2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48
1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8
2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48
1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8
2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48
1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8
2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48
1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8
WALL MOUNTED
FIBER OPTIC PATCH
PANEL
TYPICAL NURSE CALL SYSTEM RISER NOTES:
1. NURSE CALL CABINET - RAULAND BORG RS TO MATCH EXISTING.
2. NURSE CALL CABLE, 4 PR CAT 6 PER MANUFACTURER'S
RECOMMENDATIONS.
3. NURSE CALL POWER CABLE, 2-12 AWG, 1-12 EG IN 3/4" CONDUIT OR
PER MANUFACTURER'S RECOMMENDATIONS. REQUIRED ON FIRST DOME
LIGHT OR DOMELESS CONTROLLER OF EVERY SIX CONSECUTIVE
DOME LIGHTS OR DOMELESS CONTROLLERS ON CHAIN.
4. LIGHTING CONTROL CABLE, 3-20 AWG IN 3/4" CONDUIT OR PER
MANUFACTURER'S RECOMMENDATIONS.
5. NURSE CALL MULTI-COLOR DOME LIGHT.
6. NURSE CALL PATIENT BED STATION, SINGLE OR DUAL (SEE
DRAWINGS FOR CONFIGURATION). IF CODE BLUE/CODE WHITE ARE
INTEGRATED INTO BED STATION, EXTERNAL DEVICES FOR CODE
BLUE/CODE WHITE ARE NOT REQUIRED AT THAT STATION.
7. NURSE CALL PATIENT BED INTERFACE RECEPTACLE (VERIFY BED
TYPE).
8. NURSE CALL TOILET ROOM PULL CORD STATION.
9. NURSE CALL SHOWER PULL CORD STATION.
10. NURSE CALL MASTER CONSOLE STATION (TOUCH SCREEN).
11. NURSE CALL DUTY/STAFF STATION (SEE DRAWINGS FOR MORE
INFORMATION).
12. NURSE CALL DOMELESS CONTROLLER (SEE DRAWINGS FOR MORE
INFORMATION).
13. TO NURSE CALL CABINET.
14. NURSE CALL CODE STATION (SEE DRAWINGS FOR MORE INFO). IF
CODE STATIONS ARE INTEGRATED INTO BED STATION, EXTERNAL
CODE STATION DEVICES ARE NOT REQUIRED AT THAT BED STATION.
15. NURSE CALL PILLOW SPEAKER AND CONTROLS (GET WELL TV,
LIGHTING, ETC).
16. PATIENT ROOM TV (GOVERNMENT FURNISHED AND INSTALLED).
17. PATIENT ROOM LIGHTING.
TO NEXT
DOME LIGHT
TO TELECOM
ROOM
NURSE CALL
CABINET
TYPICAL PATIENT BATHROOMTYPICAL PATIENT BED
D
TV
5 N12 N D
TO GROUNDING
BUS
GENERAL NURSE CALL SYSTEM RISER NOTES:
A. PROVIDE A COMPLETE RACEWAY SYSTEM
FOR THE NURSE CALL SYSTEM IF CABLE
TRAY IS NOT AVAILABLE.
B. CONTRACTOR SHALL VERIFY RACEWAY
REQUIREMENT WITH THE NURSE CALL
SYSTEM MANUFACTURERS.
S
B
P E E
M
DUPLEX RECEPTACLE (1 - FOR
DATA)
DATA RECEPTACLE (1 -
FOR TELEMETRY)JUNCTION BOX FOR WALL SCONCE
FLOOR ELEVATION
DATA RECEPTACLE(2)
DUPLEX RECEPTACLE
DATA RECEPTACLE (2)
DUPLEX RECEPTACLE
37-PIN CONNECTOR FOR PATIENT
BED
NURSE CALL STAFF/PATIENT
STATION
CEILING ELEVATION
DUPLEX RECEPTACLE
DATA RECEPTACLE (2)
DUPLEX RECEPTACLE
NOTES:
1. REFERENCE ARCHITECTURAL PLANS FOR MORE INFORMATION.
J J J
4 4
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:1
P
M
TK502
TECHNOLOGY DETAILS
8 9RSB JDM
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 06/28/2019
BID DOCUMENTS
558-18-15018-048
Scale: N.T.S.
LOCAL AREA NETWORK RISER
Scale: N.T.S.
CCTV SYSTEM RISER DIAGRAM
Scale: N.T.S.
DATA RACK ELEVATION - TYPICAL
Scale: N.T.S.
NURSE CALL RISER DIAGRAM
Scale: N.T.S.
TYPICAL PATIENT BED SERVICE WALL ELEVATION
1' - 0"1' - 0"
LAY-IN CEILING
NOTES:
1. BUILDING STRUCTURE.
2. UNISTRUT.
3. 3/8" THREADED ROD WITH BUSHING AND NUTS.
4. CABLE TRAY.
5. GROUND LUG.
6. GROUND CABLE TO TTG.
7. PROVIDE MINIMUM CLEARANCE PER TIA/EIA 569-B.
TO GROUNDING BUS
LOCATOR SYSTEM
NW NWNWNW
TO DATA NETWORK
4 PR UTP
CEILING INFRARED
LOCATOR SENSOR
(TYPICAL)
MONITOR
PC
LOCATOR
SYSTEM PC
NOTE:
• ELECTRICAL CONTRACTOR SHALL
PROVIDE CONDUIT, BOXES,
SUPPORTS, AND CABLING. CABLING
SHALL BE PER MANUFACTURER'S
RECOMMENDATION. CONDUITS
SHALL BE A MINIMUM DIAMETER OF
3/4".
• NEW SYSTEM TO MATCH THE
EXISTING CENTRAK SYSTEM.
4 PR UTP
(TYPICAL)
(MOUNT ON TTB
NEAR NURSE CALL
CABINET)
TO GROUNDING BUS
ROAMING SYSTEM
(WANDER GUARD)
L
CEILING RECEIVER (TYPICAL)
MONITOR
PC
LOCATOR
SYSTEM PC
NOTE:
• ELECTRICAL CONTRACTOR SHALL PROVIDE
CONDUIT, BOXES, SUPPORTS, AND CABLING.
CABLING SHALL BE PER MANUFACTURER'S
RECOMMENDATION. CONDUITS SHALL BE A
MINIMUM DIAMETER OF 3/4".
• PROVIDE CEILING RECIEVER FOR FULL 5B
COVERAGE.
• PROVIDE SPARE NECK TRANSMITTERS.
• NEW SYSTEM TO MATCH THE EXISTING
STANLEY'S SYSTEM. (BUTCH'S REPAIR
SERVICES, SIDNEY (BUTCH) FLAKE 434-568-7388)
• TIE ROAMING SYSTEM IN WITH MAGNETIC
LOCKS AT EXITS AND PROVIDE
INTERCONNECTION WITH FIRE ALARM SYSTEM
L L L
NECK OR BELT
TRANSMITTER
4 PR UTP
(TYPICAL)
RK
DOOR RESET KEYPAD
120V
4 PR UTB TO ROOM B6011 ON 6TH
FLOOR, ELECTRICAL ROOM.
TO PACS EQUIPMENT
TO FIRE ALARM
K
LOCKDOWN
SWITCH AT
NURSE
STATION
MAGLOCK
DOOR
CONTACT
NURSE CALL
INTERFACE WITH
PATIENT BED (BLUE)
(1) 4 PR UTP FOR
MATV (VIOLET)
1/2" HIGH BLACK LETTERS
ON CLEAR BACKGROUND,
PANDUIT OR EQUAL ON
PERMANENT LABEL,
TYPICAL.
XXX
XXX
C B
V
BLANK
(1) RG-6 CABLE
FOR MATV
SINGLE GANG
COVER PLATE WITH
4 OUTLETS
(TYPICAL).
LOCATIONS AS
SHOWN ON PLANS
TV/MATV (TYP.) ( )
EXISTING
CABINET
WITH MATV
EQUIPMENT
5TH FLOOR
PATIENT ROOM TV
(TYPICAL)
RG-6 AND 4 PR UTP
(TYPICAL)
NOTES:
1. ALL CONDUIT SHALL RUN TO THE CABLE TRAY.
2. MINIMUM CONDUIT SIZE IS 3/4" DIAMETER.
3. PROVIDE INTERFACE TO NURSE CALL.
TO GROUNDING BUS
SSS
RGG AND 4 PRU UTP
N.C. CAB
PACS
EQUIP
TGB
2'-0"
6"
2'-0"
2'-6"
FLOOR
CCTV
EQUIP
TELEMETRY
RTLS-EQ
ROAMING EQ.
3 KVA UPS
84"
# SHEET KEY NOTES:
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:1
P
M
TK503
TECHNOLOGY DETAILS
9 9RSB JDM
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 06/28/2019
BID DOCUMENTS
558-18-15018-048
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
Scale: N.T.S.
CABLE TRAY ELEVATION - CORRIDOR
Scale: N.T.S.
REALTIME LOCATOR SYSTEM (RTLS) RISER DIAGRAM
Scale: N.T.S.
ROAMING SYSTEM RISER DIAGRAM
Scale: N.T.S.
TV OUTLET FACEPLATE
Scale: N.T.S.
MATV SYSTEM RISER DIAGRAM
Scale: 1/2" = 1'-0"
BIO MED EAST ELEVATION
Scale: 1/2" = 1'-0"
BIO MED WEST ELEVATION
GENERAL FIRE ALARM NOTES
1. PROVIDE FIRE ALARM SYSTEM AND COMPONENTS COMPLYING WITH:
A. LATEST EDITION OF NFPA 13- STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS.
B. LATEST EDITION OF NFPA 14- STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE
SYSTEM.
C. LATEST EDITION OF NFPA 20- STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE
PROTECTION.
D. LATEST EDITION OF NFPA 70 NATIONAL ELECTRICAL CODE.
E. LATEST EDITION OF NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE.
F. LATEST EDITION OF NFPA 90A STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND
VENTILATING SYSTEMS.
G. LATEST EDITION OF NFPA 101 LIFE SAFETY CODE.
H. LATEST EDITION OF VA FIRE PROTECTION DESIGN MANUAL.
I. LATEST EDITION OF ANSI S3.41 AUDIBLE EMERGENCY EVACUATION SIGNAL.
J. LATEST EDITION OF NFPA 88A STANDARD FOR PARKING STRUCTURES.
1. FIRE ALARM SYSTEM SHALL COMPLY WITH FACTORY MUTUAL RESEARCH CORPORATION (FM).
2. PROVIDE FIRE ALARM WIRING IN CONDUIT, FACTORY PAINTED RED.
3. BEFORE STARTING WORK, TEST EXISTING FIRE ALARM SYSTEM IN WORK AREA AND ADJACENT AREAS.
4. NOTIFY COR REGARDING DEFICIENCIES AND NON-OPERATING COMPONENTS. VA WILL MAKE REPAIRS.
5. WHEN WORK IS COMPLETE, TEST EXISTING FIRE ALARM SYSTEM IN WORK AREA AND ADJACENT AREAS.
6. MAKE REPAIRS TO RESOLVE INCORRECT SYSTEM OPERATIONS AT NO ADDITIONAL COST.
7. THE FIRE ALARM SYSTEM VENDOR/CONTRACTOR SHALL TERMINATE, TEST AND PROGRAM ALL NEW FIRE
ALARM DEVICES. COORDINATE WITH COR.
8. CONNECT SPRINKLER SYSTEM SUPERVISORY DEVICES TO THE FIRE ALARM SYSTEM. COORDINATE
LOCATION WITH THE SPRINKLER CONTRACTOR.
9. CONNECT ALL ELECTROMAGNETIC DOOR HOLD OPEN DEVICES TO THE FIRE ALARM SYSTEM. COORDINATE
WITH THE DOOR HARDWARE CONTRACTOR.
10. PROVIDE RELAY CONTROL MODULES FOR PACS, COORDINATE WITH PHYSICAL ACCESS CONTROL SYSTEM
(PACS), CONTRACTOR AND COR.
11. PROVIDE RELAY CONTROL MODULES FOR COOKING POWER SUPPLY SHUT OFF.
12. PROVIDE RELAY CONTROL MODULES FOR KITCHEN HOOD FIRE SUPPRESSION SYSTEM.
13. SYNC NEW STROBES WITH THE EXISTING STROBES ON THE SAME FLOOR.
FIRE ALARM SYMBOL LEGEND
FIRE ALARM PULL STATION
SYMBOL HEIGHT DESCRIPTION
ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.
TOP: HEIGHT TO TOP OF DEVICE
ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.
F
F
S
FIRE ALARM SPEAKER
FIRE ALARM STROBE
FIRE ALARM PULL SPEAKER AND STROBE
FIRE ALARM DOOR OPEN HOLDER
FIRE ALARM PHOTOELECTRIC SMOKE DETECTOR
FIRE ALARM CEILING MOUNTED SPEAKER
P
FIRE ALARM DUCT SMOKE DETECTOR
FIRE ALARM HEAT DETECTOR
48"
90"
90"
90"
FIRE ALARM PANEL
FIRE ALARM NAC PANEL
FIRE ALARM ANNUNCIATOR PANEL
FLOW SWITCH
FAP
NAC
FAAP
TAMPER SWITCH
POST INDICATOR VALVEPIV
REMOTE LIGHT/TEST SWITCH FOR DUCT DETECTORS
F FIRE ALARM BELL90"
XX - CANDELA
XX - CANDELA
XX - WATTAGEF
S
F
S
H
Fs
Ts
NOTES:
1. FIRE ALARM SYSTEM SHALL BE INTERCONNECTED WITH ACCESS CONTROL SYSTEM
TO ALLOW EGRESS DURING ALARM CONDITIONS. COORDINATE BETWEEN ACCESS
CONTROL SYSTEM AND FIRE ALARM SYSTEM MANUFACTURERS.
2. ALL FIRE ALARM WIRING SHALL BE IN FACTORY PAINTED "RED" EMT CONDUIT.
3. ALL WIRING SHALL BE AS RECOMMENDED BY MANUFACTURER.
4. PROVIDE POWER SUPPLY AND/OR NAC (NOTIFICATION APPLIANCE CIRCUIT) PANEL
AS REQUIRED FOR ADDITIONAL DEVICES (VERIFY ADEQUATE SPACE CAPACITY).
5. PROVIDE POWER AMPLIFIERS FOR ALL SPEAKERS.
6. REVISED FIRE ALARM SYSTEM SHALL BE AN EXTENSION OF THE EXISTING SIMPLEX
FIRE ALARM SYSTEM. SEE AS-BUILT DOCUMENTATION FOR FIFTH FLOOR BUILDING 1.
FS TS
TO FIELD
VERIFY CIRCUIT
INDICATING
APPLIANCES
TO ADDITIONAL FLOW
AND TAMPER
SWITCHES
TO
ADDITIONAL
INITIATING
DEVICES
EXISTING FIRE
ALARM
TERMINAL
CABINET
EXISTING SPRINKLER SYSTEM DEVICES
S S S TO EXISTING FIRE
ALARM SPEAKERS
FF F
F
RFOR PACS
R
(EX)
(EX)
R
TO ROAM ALERT
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:4
P
M
FA001
FIRE ALARM GENERAL INFORMATION
1 3RSB JDM
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 06/28/2019
BID DOCUMENTS
558-18-15018-048
Scale: N.T.S.
FIRE ALARM RISER
N
R
A
N
046636
E
E N
I
G
H
K
I
A
W
O
N
A
T
R
F
SEAL
R
P
O
O
I
SS
O E
H
RC
A
I
L
A
N
L
E
N
C
I
M
H
E
A
F
S
FA
F
F S
FA
F
F
F
F
F
F
F
F F FF
LI
M
IT
O
F P
R O
JE
C
T S
C O
P E
L L
M M
N N
P P
Q Q
R R
R.1 R.1
5.1
5.1
8 9
13 14
14 15
SS
TT
R
R
R
R
R
R
R R
R RR
R
R
Ts Fs
3 4
# SHEET KEY NOTES:
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:5
P
M
FA100
FIFTH FLOOR FIRE ALARM DEMOLITION
PLAN
2 3RSB JDM
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 06/28/2019
BID DOCUMENTS
558-18-15018-048
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
Scale: 1/8" = 1'-0"
FIFTH FLOOR FIRE ALARM DEMOLITION PLAN 0 4 8 16
NORTH
TRUE
A. COORDINATE ALL WORK WITH COR.
B. EXISTING FIRE ALARM SYSTEM OUTSIDE
AREAS OF WORK SHALL REMAIN ACTIVE
DURING CONSTRUCTION.
C. RETAIN AND REUSE DEVICES AS NOTED.
REUSE AND/OR REPLACE RACEWAYS AND
WIRING BACK TO TERMINAL CABINETS AS
REQUIRED.
D. SEE SIMPLEX/GRINNELL SHEET FA107
PROJECT #09-423425/945390101.
COORDINATE WITH COR.
E. ABANDONED CONDUIT/BOXES SHALL HAVE
ALL ELECTRICAL WIRING REMOVED
COMPLETELY AND NOT JUST MADE "SAFE".
CONDUIT/BOXES SHALL BE REMOVED
WHERE PRACTICAL WITHOUT CREATING
ADDITIONAL DEMOLITION WORK FOR
OTHER TRADES. CIRCUITS SUPPLYING
EQUIPMENT WHICH IS REMOVED UNDER
THE CONTRACT DOCUMENTS FOR ANY
DIVISION SHALL, FOR THE PURPOSES OF
THIS NOTE, BE CONSIDERED
"ABANDONED".
F. WHERE CONDUIT IS REMOVED FROM AN
EXISTING RATED ASSEMBLY NOT SUBJECT
TO DEMOLITION, THE REMAINING
PENETRATION SHALL BE
PATCHED/REPAIRED TO MAINTAIN THE
RATING OF THE ASSEMBLY.
G. DEMOLITIONS SHALL INCLUDE BUT NOT BE
LIMITED TO THOSE DEVICES AND OR
SYSTEMS NOTED. COORDINATE WITH
ARCHITECTURAL AND MECHANICAL
DEMOLITION PLANS FOR WORK SCOPE.
FIELD VERIFY EXISTING CIRCUITING.
HEAVIER LINE WEIGHT AND HATCHING
INDICATE DEMOLITION WORK. LIGHTER
LINE WEIGHT INDICATES EXISTING TO
REMAIN, VERIFY IN FIELD.
H. OWNER HAS FIRST RIGHT OF REFUSAL TO
ALL DEMOLITION ITEMS INCLUDING BUT
NOT LIMITED TO SMOKE/FIRE ALARM
DEVICES, AND ALL LIGHT FIXTURES, LAMPS
OR RELATED ASSEMBLIES. ANY ITEMS NOT
IDENTIFIED BY OWNER TO BE SAVED
SHALL BE LEGALLY DISPOSED OF IN
ACCORDANCE WITH STATE AND FEDERAL
REGULATIONS.
I. COORDINATE NOTIFICATION APPLIANCE
CIRCUITS AT THE DEMO AREAS.
1 WHERE NOTED (R), FIELD VERIFY EXISTING
FIRE ALARM CIRCUIT. EXTEND/RELOCATE TO
NEW LOCATION. FIELD VERIFY WITH EXISTING
AS-BUILT DOCUMENTATION.
2 EXISTING FLOW/TAMPER SWITCHES (FIRE
PROTECTION RISER) TO REMAIN AND BE
REUSED.
3 TAMPER SWITCH. EXISTING TO REMAIN.
CIRCUITED FROM M3-117.
4 FLOW SWITCH. EXISTING TO REMAIN.
CIRUITED FROM M3-118.
F S
F
F
F
F
F
F
F
S
F
S
F
S
F
F
F A
P
S
FA
S
FA
S
FA
S
FA
S
FA
S
FA
S
FA
S
FA
S
FA
F
F
F
F
LI
M
IT
O
F P
R O
JE
C
T S
C O
P E
PATIENT RM
B5008
CARE STATION
B5009
PATIENT RM
B5010
PATIENT RM
B5011
PATIENT RM, BARIATRIC
B5012
LOCKER
B5014
PATIENT RM
B5016
SOILED UTILITY
B5018
STAFF LOUNGE
B5015
CLEAN SUPPLY
B5019
ALCOVE
B5020
PATIENT RM
B5021
PATIENT RM
B5022 PATIENT RM
B5024
PATIENT RM
B5025
PASSAGE
B5041
NOUR
B5026
MEDS
B5027
BATH
B5007A
CORRIDOR
B5040
BATH
B5008A
BATH
B5010A
BATH
B5011A
BATH
B5016A
BATH
B5024A
BATH
B5025A
BATH
B5021A
BATH
B5022A
STAIR
B5050
STAFF TLT
B5014A
PATIENT RM, ISOLATION
B5028BATH
B5028A
ANTE
B5028B
PATIENT RM, ISOLATION
B5029
BATH
B5029A
ANTE
B5029B
PATIENT RM, BARIATRIC
B5007
CARE STATION
B5005
EQUIP
B5004
BATH
B5012A
CARE STATION
B5013
CARE STATION
B5023
NURSE MGR OFFICE
B5030
EQUIP
B5017
TEAM WORK ROOM
B5031
OIT
B5003A
ELEC
B5017A
L L
M M
N N
P P
Q Q
R R
R.1 R.1
5.1
5.1
8 9
13 14
14 15
SS
TT
R R R R
SP104
R
SP104
R
SP104
R
SP104 SP101
R
SP101 MS113 MS112
R
SP104
R
MS115
SP104
N
N
N N
N
N N
N
N
N E M3116
02 02
Ts Fs
04 05
N
R M3-114
FIRE ALARM
ZONE 5B
R R
R.1 R.1
5.1
5.1
8 9
SS
TT
J
TYP - EX FA
DEVICE MAINTAIN
SERVICE TO EXISTING
FA SYSTEM
# SHEET KEY NOTES:
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/1
/2
:3
:2
A
M
FA101
FIFTH FLOOR FIRE ALARM PLAN
3 3RSB JDM
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 06/28/2019
BID DOCUMENTS
558-18-15018-048
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
Scale: 1/8" = 1'-0"
FIFTH FLOOR FIRE ALARM PLAN 0 4 8 16
NORTH
TRUE
01 EXISTING SIMPLEX FIRE ALARM TERMINAL
CABINET. CIRCUIT NEW FIRE ALARM DEVICES
TO THIS PANEL. COORDINATE WITH COR.
02 (TYP) WHERE NOTED (R) FIRE ALARM DEVICES
ARE EXISTING TO BE RELOCATED AND
REUSED. SEE EXISTING SIMPLEX-GRINNELL
AS-BUILT DOCUMENTATION. REFERENCE
FA100.
03 SEE SHEET GC101 FOR WORK SCOPE
RELATED TO ALTERNATE DEDUCT 1.
04 TAMPER SWITCH. EXISTING TO REMAIN.
CIRCUITED FROM M3-117.
05 FLOW SWITCH. EXISTING TO REMAIN.
CIRUITED FROM M3-118.
A. COORDINATE ALL WORK AND
COMMISSIONING WITH COR.
B. INSURE COMPATIBILITY OF NEW DEVICES
WITH EXISTING SYSTEM, AND TIE NEW
DEVICES INTO EXISTING SYSTEM.
C. TEST EXISTING FIRE ALARM SYSTEM IN
WORK AREAS AND ADJACENT AREAS
PRIOR TO BEGINNING WORK AND AFTER
COMPLETION OF WORK.
D. REPAIR ANY INSUFFICIENCIES FOUND IN
EXISTING SYSTEM.
E. ALARM DEVICES INDICATED ON PLAN ARE
CIRCUITED TO FIRE ALARM CIRCUIT SP104.
F. ABANDONED CONDUIT/BOXES SHALL HAVE
ALL ELECTRICAL WIRING REMOVED
COMPLETELY AND NOT JUST MADE "SAFE".
CONDUIT/BOXES SHALL BE REMOVED
WHERE PRACTICAL WITHOUT CREATING
ADDITIONAL DEMOLITION WORK FOR
OTHER TRADES. CIRCUITS SUPPLYING
EQUIPMENT WHICH IS REMOVED UNDER
THE CONTRACT DOCUMENTS FOR ANY
DIVISION SHALL, FOR THE PURPOSES OF
THIS NOTE, BE CONSIDERED
"ABANDONED".
G. WHERE CONDUIT IS REMOVED FROM AN
EXISTING RATED ASSEMBLY NOT SUBJECT
TO DEMOLITION, THE REMAINING
PENETRATION SHALL BE
PATCHED/REPAIRED TO MAINTAIN THE
RATING OF THE ASSEMBLY.
H. DEMOLITIONS SHALL INCLUDE BUT NOT BE
LIMITED TO THOSE DEVICES AND OR
SYSTEMS NOTED. COORDINATE WITH
ARCHITECTURAL AND MECHANICAL
DEMOLITION PLANS FOR WORK SCOPE.
FIELD VERIFY EXISTING CIRCUITING.
HEAVIER LINE WEIGHT AND HATCHING
INDICATE DEMOLITION WORK. LIGHTER
LINE WEIGHT INDICATES EXISTING TO
REMAIN, VERIFY IN FIELD.
I. OWNER HAS FIRST RIGHT OF REFUSAL TO
ALL DEMOLITION ITEMS INCLUDING BUT
NOT LIMITED TO SMOKE/FIRE ALARM
DEVICES, AND ALL LIGHT FIXTURES, LAMPS
OR RELATED ASSEMBLIES. ANY ITEMS NOT
IDENTIFIED BY OWNER TO BE SAVED
SHALL BE LEGALLY DISPOSED OF IN
ACCORDANCE WITH STATE AND FEDERAL
REGULATIONS.
J. PROVIDE INTERCONNECTION BETWEEN
FIRE ALARM SYSTEM AND ROAM ALERT
SYSTEM. COORDINATE WITH COR.
Scale: 1/8" = 1'-0"
FIFTH FLOOR FIRE ALARM PLAN ALTERNATE DEDUCT 1 0 4 8 16
NORTH
TRUE
TO EXISTING
(EX) FA CIRCUITS
(MS 115M SP104)
VIF
AETHON ROBOT DOOR INTERCONNECTIONS REVISION 08/15/2019
N
R
A
N
046636
E
E N
I
G
H
K
I
A
W
O
N
A
T
R
F
SEAL
R
P
O
O
I
SS
O E
H
RC
A
I
L
A
N
L
E
N
C
I
M
H
E
A
| 08-TK, FA 100%BD |
| Sheets |
| TK001 - TECHNOLOGY GENERAL INFORMATION |
| TD101 - FIFTH FLOOR TECHNOLOGY DEMOLITION PLAN |
| TK101 - FIFTH FLOOR TECHNOLOGY PLAN |
| TK102 - FIFTH FLOOR SYSTEMS PLAN |
| TK103 - FIFTH FLOOR OVERALL SYSTEMS PLAN |
| TK104 - GROUND FLOOR TECHNOLOGY ROUTING PLAN |
| TK501 - TECHNOLOGY DETAILS |
| TK502 - TECHNOLOGY DETAILS |
| TK503 - TECHNOLOGY DETAILS |
| FA001 - FIRE ALARM GENERAL INFORMATION |
| FA100 - FIFTH FLOOR FIRE ALARM DEMOLITION PLAN |
| FA101 - FIFTH FLOOR FIRE ALARM PLAN |
| 18-048 AETHON CHANGES EE FA TK |
| Sheets |
| EP101 - FIFTH FLOOR POWER PLAN |
| E-602 - ELECTRICAL SCHEDULES |
| TK101 - FIFTH FLOOR TECHNOLOGY PLAN |
| FA101 - FIFTH FLOOR FIRE ALARM PLAN |
File details come from the government source that posted it. Updated .