Inpatient Privacy Renovate 5B
Solicitation number
36C24620R0007
Issued by

About this file

This is a presolicitation notice for an inpatient privacy renovation project at the Durham VA Medical Center. The Department of Veterans Affairs is seeking a contractor to renovate approximately 8,000 square feet of space on the fifth floor into twelve new private patient rooms and ancillary spaces. The estimated construction value is between $1,000,000 and $5,000,000. The solicitation is anticipated as a total service-disabled veteran owned small business set-aside under NAICS Code 236220 with a size standard of $36.5 million. Interested vendors should register on the website as the solicitation and any amendments will be posted there. Proposals will be due approximately 45 days after issuance of the solicitation, which is targeted for November 7, 2019. Any questions must be emailed to the point of contact listed.

36C24620R0007 0006 08-TK,_FA_100_BD.1.pdf

View the file

Other files

File Type Posted
36C24620R0007-0011001.pdf PDF
36C24620R0007-0011002.pdf PDF
36C24620R0007-0011000.docx DOCX document
36C24620R0007-0010000.docx DOCX document
36C24620R0007-0009000.docx DOCX document
36C24620R0007-0008001.pdf PDF
36C24620R0007-0008000.docx DOCX document
36C24620R0007-0007000.docx DOCX document
36C24620R0007-0006004.pdf PDF
36C24620R0007-0006000.docx DOCX document
36C24620R0007-0006003.pdf PDF
36C24620R0007-0006005.pdf PDF
36C24620R0007-0006001.pdf PDF
36C24620R0007-0006002.pdf PDF
36C24620R0007-0005000.docx DOCX document
36C24620R0007-0005001.pdf PDF
36C24620R0007-0005005.pdf PDF
36C24620R0007-0005004.pdf PDF
36C24620R0007-0005002.pdf PDF
36C24620R0007-0005003.pdf PDF
36C24620R0007-0004000.docx DOCX document
36C24620R0007-0003000.docx DOCX document
36C24620R0007-0003001.pdf PDF
36C24620R0007-0002002.pdf PDF
36C24620R0007-0002001.docx DOCX document
36C24620R0007-0001001.pdf PDF
36C24620R0007-023.pdf PDF
36C24620R0007-022.docx DOCX document
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADO AUTOMATIC DOOR OPERATOR

AFF ABOVE FINISH FLOOR

CCTV CLOSED CIRCUIT TELEVISION

COAX COAXIAL CABLE

COMM COMMUNICATION

COR CONTRACTING OFFICER

REPRESENTATIVE

DC DOOR CONTACT SWITCH

DN DOWN

DO DOOR OPERATOR

DVR DIGITAL VIDEO RECORDER

EEB EMERGENCY EXIT BUTTON

EL ELECTRICAL STRIKE

FA FIRE ALARM

FAP FIRE ALARM PANEL

FAAP FIRE ALARM ANNUNCIATOR PANEL

FO FIBER OPTIC

IT INTERCOMMUNICATION ROOM

MATV MASTER ANTENNA TELEVISION

MM MULTI MODE FIBER

NAC NETWORK APPLIANCES CONTROL PANEL

NS NO SCALE

NTS NOT TO SCALE

NVR NETWORK VIDEO RECORDER

TECHNOLOGY ABBREVIATIONS LIST

OC ON CENTER

OIT OFFICE OF INFORMATION TECHNOLOGY

PACS PHYSICAL ACCESS CONTROL SYSTEM

PAMN PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEM

PB PUSH BUTTON

PDU RACK POWER DISTRIBUTION UNITS

POE POWER OVER ETHERNET

PR PAIR

RX REQUEST TO EXIT

SEP SERVICE ENTRANCE PROTECTION

SM SINGLE MODE FIBER

TEL TELEPHONE

TGB TELECOMM GROUND BUS BAR

TM TELEMONITORING

TMGB TELECOMM MAIN GROUND BUS BAR

TP TWISTED PAIR

TR TELECOMM ROOM

TTB TELEPHONE TERMINAL BOARD

TV TELEVISION

WM WIRE MANAGEMENT

WAP WIRELESS ACCESS POINT

UL UNDERWRITERS LABORATORY

UPS UNINTERRUPTIBLE POWER SUPPLY

UTP UNSHIELDED TWISTED PAIR

GENERAL TECHNOLOGY NOTES

1. PROVIDE COMMUNICATIONS DEVICES AND EQUIPMENT IN ACCORDANCE WITH THE CONTRACT

DOCUMENTS, MANUFACTURER'S RECOMMENDED PROCEDURES, ALL APPLICABLE LOCAL AND

STATE CODES, AMERICANS WITH DISABILITIES ACT, LATEST EDITION OF THE NATIONAL

ELECTRICAL CODE, BICSI STANDARDS, AND VA STANDARDS.

2. PROVIDE ADDITIONAL SUPPORT FOR DEVICES AND EQUIPMENT WHERE BUILDING

CONSTRUCTION IS NOT SUITABLE FOR DIRECT MOUNTING.

3. FIRESTOP, DRAFTSTOP, SMOKESTOP OR PROTECT ANNULAR SPACE AROUND PENETRATIONS

THROUGH WALLS, PARTITIONS, FLOORS, CEILINGS, AND ROOF IN ACCORDANCE WITH

REQUIREMENTS OF NFPA 70, UL LISTING REQUIREMENT AND APPLICABLE BUILDING CODES.

4. PROVIDE CABLING THAT COMPLIES WITH LATEST EDITION OF TELECOMMUNICATIONS

DISTRIBUTION METHOD MANUAL AND ANSI/TIA/EIA PUBLICATIONS.

5. COMPLY WITH LATEST EDITION OF ANSI/TIA/EIA 758 AND 607B OR 607A - GROUNDING AND

BONDING REQUIREMENTS FOR TELECOMMUNICATIONS IN COMMERCIAL BUILDING.

6. COMPLY WITH LATEST EDITION OF ANSI/TIA/EIA 568B - COMMERCIAL BUILDING

TELECOMMUNICATIONS WIRING STANDARD.

7. COMPLY WITH LATEST EDITION OF ANSI/TIA/EIA 569B - COMMERCIAL BUILDING STANDARD FOR

TELECOMMUNICATIONS PATHWAYS AND SPACES.

8. COMPLY WITH LATEST EDITION OF NFPA 70 NATIONAL ELECTRICAL CODE.

9. COMPLY WITH LATEST EDITION OF NFPA 99 HEALTHCARE FACILITIES CODE.

10. COMPLY WITH LATEST EDITION OF NFPA 101 LIFE SAFETY CODE.

11. COORDINATE WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION.

12. MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE PURPOSES, TO

INDICATE A QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A PARTICULAR

MANUFACTURER. PRODUCTS DEEMED EQUAL AND APPROVED BY THE COR WILL BE

ACCEPTABLE. COMPLY WITH "BUY AMERICAN ACT".

13. MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, BOXES, OUTLET, OR EQUIPMENT

UNLESS NOTED OTHERWISE.

14. PROVIDE RGS OR EMT CONDUIT UNLESS OTHERWISE NOTED.

15. PROVIDE MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT LABEL LISTED BY APPROVED

THIRD PARTY TESTING AGENCY.

16. NOTIFY COR REGARDING DISCREPANCY BETWEEN PLANS AND SPECIFICATIONS FOR

CLARIFICATION. THE MORE STRINGENT OF THE THEM SHALL TAKE PRECEDENCE.

17. FOR LOCATION (CORRIDOR, ROOM OR ADJACENT SPACE) WITH TWO OR MORE VISIBLE FIRE ALARM NOTIFICATION APPLIANCES WITHIN THE FIELD OF VIEW, PROGRAM VISIBLE TO FLASH IN

SYNCHRONIZATION.

18. PROVIDE TIA/EIA CAT 6 COPPER OUTLETS AND CONNECTORS.

19. ALL WORK AREA OUTLETS SHALL BE 8 PIN, CAT 6 KEYSTONE JACK WIRED PER T568A OR T568B

AS DIRECTED BY THE VA COR.

20. LABEL DEVICES IN ACCORDANCE WITH LATEST ANSI/TIA 606A OR 606B EDITION AS WELL AS THE

STANDARDS SET FORTH BY THE VA HOSPITAL OIT.

21. PROVIDE A MINIMUM OF 12" CLEARANCE ABOVE THE CABLE TRAY PER TIA/EIA 569.B PARAGRAPH 4.5.6.2.

22. VA WILL CONDUCT A WIRELESS ACCESS POINT SURVEY AND PROVIDE THE SURVEY TO THE

CONTRACTOR. INSTALL CABLING AND EQUIPMENT IN ACCORDANCE WITH THE SURVEY.

COORDINATE WITH COR/OIT.

23. ALL CABLING INSTALLED ABOVE CEILING SHALL BE PLENUM RATED.

TECHNOLOGY SYMBOL LEGEND

DATA OUTLET - 2-4 PR UTP

DATA OUTLET - 1-4 PR UTP

TELCO OUTLET - 1-4 PR UTP

SYMBOL HEIGHT DESCRIPTION

18"

18"

48"

ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.

ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.

SEE DRAWINGS FOR MORE INFORMATION.

NOTE: NOT ALL SYMBOLS ARE USED.

ELECTRONIC LOCKING MECHANISM

DOOR CONTACT

REQUEST FOR EXIT SENSOR

CARD READER

(K - KEYPAD)

48"CR

ES

DC

RX

48" EMERGENCY EXIT BUTTON TO RELEASE DOOR (EEB)

WIRELESS ACCESS POINT - 2-4 PR UTP

WALL PHONE-1-4W

N

S NURSE CALL PATIENT STATION WITH PILLOW SPEAKER (GET WELL)

(1 - SINGLE, 2 - DUAL, V - VANDAL RESISTANT)

P

NURSE CALL PATIENT BED INTERFACE RECEPTACLE

B

NURSE CALL CODE BLUE STATION

E NURSE CALL EMERGENCY STATION WITH PULL CORD AND AUDIO +40" AFF IN

RESTROOM, +72" AFF IN SHOWER (V - VANDAL RESISTANT, PB - PUSH BUTTON)

D

NURSE CALL DUTY STATION

M

NURSE CALL MASTER STATION/CONSOLE

NURSE CALL DOME LIGHT

(Z - ZONE LIGHT, V - VANDAL RESISTANT)

IC

INTERCOM WITH CAMERA

IC

INTERCOM MASTER WITH PUSH TO RELEASE DOORM

NURSE CALL WIRELESS ANTENNAS / RTLSNW

DATA OUTLET - 4-4 PR UTP18"

TV OUTLET WALL MOUNTED, 1-4 PR UTP, 1-RG6

48"

54"

DESK

CCTV DOME CAMERA FIXED

CCTV DOME CAMERA PAN/TILT/ZOOM

FOUR POST OIT EQUIPMENT RACK

OIT EQUIPMENT CABINET

NURSE CALL EQUIPMENT CABINET

MATV EQUIPMENT CABINET

CCTV EQUIPMENT CABINET

NCE

MATV

CCTV

LADDER CABLE TARY

FLOOR BOX FOR DATA

AS NOTED

DOOR

DOOR

ABOVE

DOOR

HEADWALL

18"

HEADWALL

/40"

40",72"

18"

60"

CEILING

CEILING

6' TO TOP

6' TO TOP

FLOOR

PHYSICAL ACCESS CONTROL SYSTEMPACS 6' TO TOP

ELECTRONIC PANIC HARDWAREEP

DO

DOOR OPERATOR

HANDWAVE

T

C

NURSE CALL STAFF TERMINAL

NURSE CALL PATIENT STATION WITH CALL CORD.

(1 - SINGLE, 2 - DUAL, V - VANDAL RESISTANT)

48"

HEADWALL

W WIRELESS PENDANT

L

KP PATIENT ROAM ALERT ACCESS CONTROL KEYPAD48"

PATIENT ROAM ALERT ANTENNACEILING

GROUND BUS

CEILING

DOOR

DOOR

48"

ABOVE

DOOR

NURSE CALL DOME LIGHT

FLOOR

FLOOR

FLOOR

ABOVE

CEILING

18"

4'x8'x3/4" FIRE RATED TTB8"

DATA OUTLET - 6-4 PR UTP18"6

N

M

PATIENT STATION (PB - PUSH BUTTON, M - MICROPHONE, K -KEYED)

88" MOTION DETECTOR

MD

FLOOR TWO POST OIT EQUIPMENT RACK

CEILING MOUNTED SPEAKERSCEILING

WALL MOUNTED SPEAKERS96"

S

S

AREA OF REFUGE PANEL6' TO TOP

AREA OF REFUGE ANNUNCIATION PANEL6' TO TOP

AOF

AOFA

IC AREA OF REFUGE INTERCOM48"

AREA OF REFUGE STROBE LIGHTCEILINGSL

DP

DPP

DURESS PANIC ALARM PUSH BUTTON48"

DURESS PANIC ALARM PANEL6' TO TOP

N

ANTENNA (REFERENCE SHEET KEY NOTES)CEILING

RTLS VIRTUAL WALL (BATTERY POWERED INFRARED DEVICECEILING

RTLS MONITOR (BATTERY POWERED INFRARED DEVICE)CEILING

RTLS 900 MHz SECURITY CONTROLLER (POE)CEILINGSTAR

M

VW

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:1

:5

P

M

TK001

TECHNOLOGY GENERAL INFORMATION

1 9RSB JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048 kgenther Model

ELEVATOR

SS S

S

S

S

S S S

4 4 4

S

LI

M

IT

O

F P

R O

JE

C

T S

C O

P E

L L

M M

N N

P P

Q Q

R R

R.1 R.1

5.1

5.1

8 9

13 14

14 15

SS

TT

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:1

:5

P

M

TD101

FIFTH FLOOR TECHNOLOGY

DEMOLITION PLAN

2 9RSB JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

Scale: 1/8" = 1'-0"

FIFTH FLOOR TECHNOLOGY DEMOLITION PLAN 0 4 8 16

NORTH

TRUE

A. REMOVE ALL DEVICES, CONDUIT, AND

WIRE BACK TO SOURCE.

B. ALL EXISTING CONDITIONS, CONDUIT, AND

DEVICES ARE BASED ON BEST AVAILABLE

INFORMATION AT TIME OF ENGINEERING

SURVEY AND VISUAL INSPECTION. VERIFY

EXISTING CONDITIONS.

C. TURN ALL EQUIPMENT (CAMERAS, WAP,

ETC.) TO COR.

E

E E

E

E E

E

SS

E

EE

E

E

D

D

D

M

D

M

2 4

2 4

4 2

66"

66" 66"

66"

N 1

N 1 N 1 N 1

N 1

N 1

N 1

N 1

N 1 N 1

N 1 N 1

60"

E

E

EE

E

E E

E

E

E

E E

DD

D

DD

P P

2 2 2 2

D

4 4 4

NW

NW

NWNWNW NW NW

DD

S P S

P

S P

S P

S P S P

S P

S P

S P

S P

60"

60"

60"

60"

2 60

2 2

W W

N 2

4 4

LI

M

IT

O

F P

R O

JE

C

T S

C O

P E

PATIENT RM

B5008

CARE STATION

B5009

PATIENT RM

B5010

PATIENT RM

B5011

PATIENT RM, BARIATRIC

B5012

LOCKER

B5014

PATIENT RM

B5016

SOILED UTILITY

B5018

STAFF LOUNGE

B5015

CLEAN SUPPLY

B5019

ALCOVE

B5020

PATIENT RM

B5021

PATIENT RM

B5022 PATIENT RM

B5024

PATIENT RM

B5025

PASSAGE

B5041

NOUR

B5026

MEDS

B5027

BATH

B5007A

CORRIDOR

B5040

BATH

B5008A

BATH

B5010A

BATH

B5011A

BATH

B5016A

BATH

B5024A

BATH

B5025A

BATH

B5021A

BATH

B5022A

STAIR

B5050

STAFF TLT

B5014A

PATIENT RM, ISOLATION

B5028

BATH

B5028A

ANTE

B5028B

PATIENT RM, ISOLATION

B5029

BATH

B5029A

ANTE

B5029B

PATIENT RM, BARIATRIC

B5007

CARE STATION

B5005

EQUIP

B5004

BATH

B5012A

CARE STATION

B5013

CARE STATION

B5023

NURSE MGR OFFICE

B5030

EQUIP

B5017

TEAM WORK ROOM

B5031

ELEC

B5017A

OIT

B5003A

TK101

L L

M M

N N

P P

Q Q

R R

R.1 R.1

5.1

5.1

8 9

13 14

14 15

SS

TT

05 05

050505

0404 04 04

1 1 22

11 06

13 13 13 13 13

151415151514

BIO

B5003

M

N

P

R R

R.1 R.1

5.1

5.1

8 9

SS

TT

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/1

/2

:3

:2

A

M

TK101

FIFTH FLOOR TECHNOLOGY PLAN

3 9RSB JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

Scale: 1/8" = 1'-0"

FIFTH FLOOR TECHNOLOGY PLAN

01 PROVIDE 3-4" FIRE/SMOKE UL LISTED SLEEVE

ASSEMBLY.

02 PROVIDE NEW IT FLOOR HINGED EQUIPMENT

RACK.

03 PROVIDE LADDER TRAY.

04 PATIENT WIRELESS ACCESS POINT

LOCATIONS.

05 INTERFACE TV WITH PATIENT NURSE CALL AND

BED.

06 NURSE CALL EQUIPMENT.

07 PACS EQUIPMENT. MOUNT BELOW NURSE

CALL CABINET.

08 PROVIDE 3/4" FIRE RETARDANT PLYWOOD

WITH TGB.

09 SEE SHEET GC101 FOR WORK SCOPE RELATED

TO ALTERNATE 1.

10 (TYP) PROVIDE 2-4 PR UTP TO THE TELEMETRY

SYSTEM IN EACH PATIENT ROOM, TERMINATE

ON PATCH PANELS IN THE BIOMED ROOM.

TYPICAL OF ALL PATIENT ROOMS.

11 PROVIDE 2-4 PR UTP FOR THE TELEMETRY

MONITORING SYSTEM AND TERMINATE ON

PATCH PANELS IN THE BIOMED ROOM. THE

OTHER 2-4 PR UTP ARE FOR IT. TERMINATE ON

PATCH PANEL IN OIT ROOM.

12 LOCATION OF EXISTING MATV PANEL.

13 (TYP) PENDANT TELEMETRY ANTENNA.

PROVIDE 3-4 PR UTP TO EACH ANTENNA &

TERMINATE ON PATCH PANEL IN NEW BIOMED

ROOM.

14 PROVIDE 3-4 PR UTP FOR FUTURE RTLS,

TERMINAL ON PATCH PANELS IN BIO MED RM.

LABEL ETLS. CABLE COLOR TO BE

COORDINATED WITH COR/IT.

15 PROVIDE 4 PR UTP FOR MEDS TUG ROBOT

(PHARMACY) AND TERMINATE IN BIO MED

ROOM. LABEL PHARMACY. COLOR TO BE

COORDINATED WITH COR/IT.

16 PATIENT WIRELESS CABLE TO BE RUN TO THIS

LOCATION. PROVIDE 15FT. SLACK, COIL

CABLES AND SUPPORT FROM CEILING.

17 PROVIDE FLOOR HINGED EQUIPMENT RACK

FOR BIO MED QUIPMENT.

18 PROVIDE WALL MOUNTED 24 PORT FIBER

OPTIC PATCH PANEL.

19 PROVIDE NEW TGB.

Scale: 1/2" = 1'-0"

OIT B5004A ENLARGEMENT

Scale: 1/8" = 1'-0"

FIFTH FLOOR TECHNOLOGY PLAN ALTERNATE DEDUCT 1 0 4 8 16

NORTH

TRUE

0 2 4 8

NORTH

TRUE

PROVIDE (2)

4" SLEEVE

ASSEMBLIES

A. COORDINATE PATIENT HEADWALL

TECHNOLOGY CONNECTIONS WITH DEVICE

MANUFACTURER AND COR.

B. TELEMETRY ANTENNA LOCATIONS SHALL BE

FIELD VERIFIED BY THE MANUFACTURERS.

COORDINATE WITH VA VENDOR.

C. COORDINATE CABLE TRAY WITH ALL TRADES

ON THE JOB SITE.

D. PROVIDE 20 FOOT LOOP FOR WIRELES

ACCESS POINTS.

E. SEE HEADWALL DETAIL ON TK502 AND QH102.

0 4 8 16

NORTH

TRUE

AETHON ROBOT DOOR INTERCONNECTIONS REVISION 08/15/2019

N

R

A

N

046636

E

E N

I

G

H

K

I

A

W

O

N

A

T

R

F

SEAL

R

P

O

O

I

SS

O E

H

RC

A

I

L

A

N

L

E

N

C

I

M

H

E

A

L

S

CRCRCRCRCR CR

CR

CR CRDC

DC

DC

DC

DCDC

DC DC

ESES

ES

ES

ES

ES

ES ES

CR

RX RX RX

RX RX

RXRX

RX RX

ESDC

RX

ESDC

RK

RK

RK

L

L

L

ELRX DC

CR

CR

EL

RX

EL

LI

M

IT

O

F P

R O

JE

C

T S

C O

P E

PATIENT RM

B5008

CARE STATION

B5009

PATIENT RM

B5010

PATIENT RM

B5011

PATIENT RM, BARIATRIC

B5012

LOCKER

B5014

PATIENT RM

B5016

SOILED UTILITY

B5018

STAFF LOUNGE

B5015

CLEAN SUPPLY

B5019

ALCOVE

B5020

PATIENT RM

B5021

PATIENT RM

B5022 PATIENT RM

B5024

PATIENT RM

B5025

PASSAGE

B5041

NOUR

B5026

MEDS

B5027

BATH

B5007A

CORRIDOR

B5040

BATH

B5008A

BATH

B5010A

BATH

B5011A

BATH

B5016A

BATH

B5024A

BATH

B5025A

BATH

B5021A

BATH

B5022A

STAIR

B5050

STAFF TLT

B5014A

PATIENT RM, ISOLATION

B5028

BATH

B5028A

ANTE

B5028B

PATIENT RM, ISOLATION

B5029

BATH

B5029A

ANTE

B5029B

PATIENT RM, BARIATRIC

B5007

CARE STATION

B5005

EQUIP

B5004

BATH

B5012A

CARE STATION

B5013

CARE STATION

B5023

NURSE MGR OFFICE

B5030

EQUIP

B5017

TEAM WORK ROOM

B5031

OIT

B5003A k

L L

M M

N N

P P

Q Q

R R

R.1 R.1

5.1

5.1

8 9

11 12

13 14 15

S

T

0202 02

VW

VW

VW

VW

VW

VW

VW

VW

VW

VW

VW

VW

VW

VW

VW

VW

VW

VW

VW

VW

VW

VW

VW

VW

V W

V W

V W

V W

V W

V W

V W

V W

M

MM

M

M

M M

M

MM

M

M M M

M

M

VW VW

STARSTAR

STAR

K

VW VW

R R

R.1 R.1

5.1

5.1

8 9

S

T

SOILED UTILITY

B5018

CLEAN SUPPLY

B5019

ALCOVE

B5020

NOUR

B5026

MEDS

B5027 BATH

B5028A

EQUIP

B5017

N

P

9 10

ELECTRICAL CLOSET

B6011

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:1

:0

P

M

TK102

FIFTH FLOOR SYSTEMS PLAN

4 9RSB JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

Scale: 1/8" = 1'-0"

FIFTH FLOOR SECURITY PLAN

0 4 8 16

NORTH

TRUE

01 SEE SHEET GC101 FOR WORK SCOPE

RELATED TO ALTERNATE DEDUCT 1.

02 (TYP) CABLE TRAY AS INDICATED ON TK101.

03 CAT 5/6 POE DROP LOCATION.

04 PHARMACY PENDANT ANTENNA. PROVIDE 1-4

PR UTP TO EACH ANTENNA & TERMINATE ON

PATCH PANEL IN NEW BIOMED ROOM.

05 PROVIDE (3)RUNS OF 4 PR UTP TO IT ROOM.

LABEL RTLS_CABLING.

06 LOCKDOWN SWITCH

07 LOCATION OF EXISITNG ROAMING DATA

SWITCH. SEE DETAIL 2 ON TK503 FOR MORE

INFO.

08 ELECTRICAL ROOM B6011 CONTAINING

EXISTING ROAMING DATA SWITCH. LOCATED

ON FLOOR ABOVE IN THIS LOCATION.

REFERENCE VIEW 3 THIS SHEET.

09 INTERLOCK AETHON ROBOT SYSTEM WITH

THE PACS DOORS. AS THIS WILL HELP THE

ROBOT OPEN THE DOORS.

A. TELEMETRY ANTENNA LOCATIONS SHALL BE

FIELD VERIFIED BY THE MANUFACTURERS.

COORDINATE WITH VA VENDOR.

B. FIELD VERIFY PHARMACY ANTENNAS WITH THE

VA VENDOR.

Scale: 1/8" = 1'-0"

FIFTH FLOOR SECURITY PLAN

0 4 8 16

NORTH

TRUE

Scale: 1/4" = 1'-0"

SIXTH FLOOR ROOM B6011 0 4 8 16

NORTH

TRUE

OFFICE

OFFICE

ORTHOPEDIC

ORTHOPEDIC

SGY SGY

OFFICE

OFFICE OFFICE

OFFICE

STORAGE

OFFICE

OFFICE

WORK RM

BIOHAZARD

SOILED UTILITY

WORKER

NURSING

SVC CO-ORDR

MEN

STORAGE

OFFICERESP CARE

CHIEFCHIEF PULM

OFFICEOFFICEOFFICEOFFICE

CLEAN SUPPLYRESP CARE OFFICE

RESP CARE PATIENT

EDUCATION EXERCISE

TESTING

RESP CARE

LOCKERS

LOCKERPULM SECYOFFICE

OFFICE

PATIENT ROOM

PATIENT RM

WOMENS

FAMILY/WAITING

CONSULTATION

CALL RM

UTILITY

SOILED

MICU

ELECTRICAL

MEDICATION

CLOSET

OFFICE HOME

STORAGE

EQUIPMENT

EXAM / TREATMENT

STAFF OFFICE

OFFICE

DUMB WAITER

SURG RISK

ASSESSMENT NURSE WORK RM

CHIEF

PLASTIC

SURGY

NEURO SURGY

ADMIN OFFICER

CHIEF SURG SVC

OFFICE

OFFICE

OFFICE CONFERENCE RM

BATH RM URODYNAMICS

CYTOSCOPY

CHECK-IN

KEEPING

EXAM

SUPPLY

WOMENS

MALE

PATIENT RM

OFFICE

ANESTHESIOLOGY

LINEN

SOILED

UTILITY

OFFICE

BATH RM

WAITING AREA

CHIEF

ANESTHESIOLOGY

ENT/CARDIOTHORACIL

PGM SUPPORT

RESIDENCY PROGR

LOCKER

MENS LOCKER

STORAGE

CHIEF

GENERAL SURGY

OFFICE

OFFICE

CHIEF

OTOLARYNGOLOGY

OFFICE

OFFICE

CHIEF UROLOGY

WOMENS

MALE

KEEPING

STORAGE

KEEPING

ELEVATOR

ELEVATOR

KEEPING

ORTHOPEDIC

PATIENT ROOM

HOUSE

HOUSE

HOUSE

STAIR-3

DUMB WAITER

CONFERENCE RM

SHAFT

FIRE PROTECTION CLOSET

FIRE PROTECTION CLOSET

STAIR-2

NEUROLOGY

HOUSE KEEPING

TELEPHONE

C5001A-1

HOUSE

KEEPING

GENERAL

STORAGE

IRM CLOSET

CLEAN LINEN

8-BED ICU

7-BED ISOLATION

6-BED ICU

1-BED ICU

STAFF LOUNGE

MICU

ROOM

MEN

FIRE PROTECTION

STORAGE

CLOSET

CLOSET FIRE

PROTECTION

CLOSET

MECH RM

STORAGE

FIRE PROTECTION CLOSET

STAIR-4

STORAGE

FIRE PROTECTION CLOSET

STAIR-5

ANEST

EDUCATION LAB

MULTI PURPOSE

RM

ANTE RM

ANTE RM

DUMB WAITER ELEVATOR ELEVATOR

ELEVATOR ELEVATOR

OFFICE

PATIENT RM

PATIENT RM

2-BED ISOLATION

ANESTHESIOLOGYANESTHESIOLOGYANESTHESIOLOGY

OFFICE OFFICE OFFICE

EQUIPMENT STORAGE

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

STORAGE

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

OFFICE CUBICLES

SURG

OFFICE

4-BED

WOMENS

STAFF

ANESTHESIOLOGY

SOCIAL

PHYSICIANS

CLOSET

PATIENT RM MICU

5-BED ICU

PATIENT RM

4-BED ICU

PATIENT RM

3-BED MICU

UTILITY

STORAGE

PULM

OXYGEN CO-ORDR

UROLOGY

OFFICE ANESTHESIOLOGY

OFFICE

ANESTHESIOLOGY

OFFICE

ANESTHESIOLOGY

OFFICE

EXAM EXAM

EXAM /

CHECK-IN

EXAM EXAM

EXAM EXAM

EXAM

GENERAL

GENERAL

CLEAN

FIRE

RM

BREAK

GENERAL

STORAGE

GENERAL

TOILET TOILET

VESTIBULE

VESTIBULE

EQUIPMENT

BEDS &

CLOSET

OIT

OFFICE

OFFICE

GENERAL

STORAGE

GENERAL

STORAGE

GENERAL

TOILET STORAGE

GENERAL

STORAGE

EQUIPMENT

UTILITY

SOILED

BED

EXAM / TREATMENT

STORAGE

EQUIPMENT

EXAM

BREAK

CLEAN

NURSES

STATION

B5029

LINEN CHUTE

D5008

B5002

A5002A

C5008

C5006

C5004

C5002

C5026

C5032

C5034

C5036

C5046

C5044

C5020

C5018

C5016

C5017

C5019

C5021

C5023

C5025

C5027

C5015 C5009

C5011

C5029 C5050

D5013

D5007

D5014

D5011

D 5028

D5024

D5021

D5019 D5017

D5020

D5018

D5015

D5022

D5005

D5003

D5001

D5012

D5010

D5002

D5000

C5001

C5003

A5018 A5010

A5020

A5017

A5015

A5009

A5005A5001

A5002 A5006 A5024 A5026 A5028 A 5030

A5021

A5016

A5014A

A5014C

A5014B

A5014D

A5023

A5032

A5040

A5027

A5029

A5025

A5035

A5037

A5039

A5050

A5052A

A5052

A5054

A5056

A5058

A5031

D5026

D A5033

A5007

A5007AC5013

D5023

D5016A

A5002B

D5015A

D5015B

A5003

D5013A

C

B A

C5010A

A5008 A5000

A5004A A5022

A5019

A5011 A5013

A5048 A5046 A5044 A5042A

A5034

A5036

A5038

A5012

C5012

D5016 D5004D5006

D5019A

C5030

C5048

A5004B

C5010

5009A

A5043

A5034A

A5042

A5058A A5058B

C5043A

C5046A

C5046A C5044A

D5017C

D5022B D5022A

D5019B D5017B D5017A

D5005A

D5003B D5001AD5001B

D5004B D5002BD5008B D5006B

D5010A

C5019A

C5022

C5014A

D5003A

D5021A

TOILET

C5046B

TOILET

C5048A

C5028

C5014

A5001A

C5000

C5009A

A5016

A5021A

A5041 A5041A

TUBE SYSTEM

LI

M

IT

O

F P

R O

JE

C

T S

C O

P E

PATIENT RM

B5008

CARE STATION

B5009

PATIENT RM

B5010

PATIENT RM

B5011

PATIENT RM, BARIATRIC

B5012

LOCKER

B5014

PATIENT RM

B5016

SOILED UTILITY

B5018

STAFF LOUNGE

B5015

CLEAN SUPPLY

B5019

ALCOVE

B5020

PATIENT RM

B5021

PATIENT RM

B5022

PATIENT RM

B5024

PATIENT RM

B5025

PASSAGE

B5041

NOUR

B5026

MEDS

B5027

BATH

B5007A

CORRIDOR

B5040

BATH

B5008A

BATH

B5010A

BATH

B5011A

BATH

B5016A

BATH

B5024A

BATH

B5025A

BATH

B5021A

BATH

B5022A

STAIR

B5050

STAFF TLT

B5014A

PATIENT RM, ISOLATION

B5028

BATH

B5028A

ANTE

B5028B

PATIENT RM, ISOLATION

B5029

BATH

B5029A

ANTE

B5029B

PATIENT RM, BARIATRIC

B5007

CARE STATION

B5005

EQUIP

B5004

BATH

B5012A

CARE STATION

B5013 ?

CARE STATION

B5023

NURSE MGR OFFICE

B5030

EQUIP

B5017

TEAM WORK ROOM

B5031

OIT

B5003A

L

M

N

P

Q

R

R.1

5.1

5.1

8 9

13 14 15

SS

TT

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:1

:0

P

M

TK103

FIFTH FLOOR OVERALL SYSTEMS PLAN

5 9RSB JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

Scale: 1/16" = 1'-0"

FIFTH FLOOR OVERALL TECHNOLOGY PLAN

01 3-4" FIRE/SMOKE UL LISTED SLEEVE

ASSEMBLY. SEE TK101.

02 TECHNOLOGY FEEDER FOR NEW IT ROOM. 24

MM 50 MICRON TIGHT BUFFERED ARMORED

OM4 FIBER AND 25 PR TELECOM CABLE FROM

NEW 5B IT ROOM TO MAIN SERVER ROOM

FG104.

03 PROVIDE 4" FIRE/SMOKE UL LISTED SLEEVE

ASSEMBLY.

04 LOCATION OF EXISTING NURSE CALL

INTERFACE. COORDINATE CONNECTION TO

EXISTING NURSE CALL SYSTEM WITH SITE

BIOMEDICAL AND COR.

05 NURSE CALL INTERFACE CABLING. RUN 2-4PR

UTP AND 1-4 STRAND FIBER OPTIC (OM4)

CABLE. COORDINATE CONNECTION TO

EXISTING NURSE CALL SYSTEM WITH SITE

BIOMEDICAL AND COR.

06 NEW NURSE CALL EQUIPMENT CABINET.

COORDINATE WITH COR AND BIOMED.

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

0 8 16 32

NORTH

TRUE

FG144A

EG017A

GENERAL

LAB

STORAGE

TO CRAWL

SPACE

TO CRAWL

RAMP

RAMP

BG000

BG001

AG002A

AG000A

AG002

CG008

S4

S5 P3

P2

P1 P7

P6

P5

AG005

AG009

AG011AG012

AG009A

AG008

AG015A

AG015B

AG003

CG009

CG007

CG010

BG003

FG145

FG146A

EG006

EG013

EG015

EG017

EG007

EG011

EG009

EG018

EG010

EG014

EG012

EG008

EG004

EG005

EG002

EG003

FG156

FG155

FG154

FG143

FG137A

FG147FG146 FG147A

FG142

FG148

FG149

FG157

FG158

FG104

FG160

FG160A

FG159

AG017

AG015

AG010

EG005A

EG007A

EG001

FG43

FG141

FG104A

FG156A

FG151

BG001A

AG001

EG003A EG003B

EG012A

EG018A

EG017A

FG1000

CG003

ROLLING

SHUTTER

UP

DN

STAIR-1

CANTEEN STORAGE

OFFICE

MORGUE

OFFICE

FREEZER

OFFICE

VENDING RM

KEEPING

CPR EQUIP

CANTEEN CANTEEN

OFFICE

FREEZER

STAIR-12

FIRE PROTECTION

HOUSE

ELECTRICAL RM

TELEPHONE

CLOSET

ISO OFFICE

KEEPING

OFFICE

LAB

OFFICE

OFFICE

OFFICE

STORAGE

STORAGE

STORAGE

RESEARCH

AFGE

AFGE

DECEDENT

AFFAIRS OFFICE ISO OFFICE

IRM OFFICE

CLOSET TOILET

SERVER RM

TELECOM

TELECOM

OFFICE

CLOSET

ELEVATOR

ELECTRICAL

HOUSE

LAB

FIRE PROTECTION

STORAGE

IRM OFFICE

STORAGE

CANTEEN

STAIR-10

HAC

DUMB WAITER

DUMB WAITER

GREEN

ELEVATOR

GREEN

ELEVATOR

GREEN

ELEVATOR

OFFICE

DUMB WAITER

FIRE PROTECTION

FIRE

CANTEEN

STORAGE

LINEN

CHUTE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

ELEVATOR

CAFETERIA

CAFETERIA

LINEN

CHUTE LINEN

CHUTE

SHAFT

MENS TOILET

TRASH RM

FEMALE TOILET

FEMALE TOILET

CORRIDOR

CORRIDOR

CORRIDOR

RETAIL STORE

MECH

RETAIL STORE

RECORDS RM

OFFICE, PRIVACY

CANTEEN DINING

CANTEEN DINING

CANTEEN DINING

KITCHEN

CANTEEN DINING

OFFICE

CORRIDOR

OFFICE, NURSING UNION ISO OFFICE

CORRIDOR

CORRIDOR

MECH RM

CORRIDOR

CORRIDOR

ELECTRICAL

ELECTRICAL

PROTECTION

446. 3969

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:1

:0

P

M

TK104

GROUND FLOOR TECHNOLOGY

ROUTING PLAN

6 9RSB JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

Scale: 3/32" = 1'-0"

GROUND FLOOR TECHNOLOGY ROUTING PLAN

01 PROVIDE 4" FIRE/SMOKE UL LISTED SLEEVE

ASSEMBLY.

02 EXISTING SERVER ROOM. PROVIDE 24 PORT

FIBER PATCH PANEL WITH COUPLERS.

COORDINATE LOCATION WITH COR.

03 NEW FIBER TO 5TH FLOOR.

04 NEW 24 MM 50 MICRON TIGHT BUFFERED

ARMORED FIBER (OM4) AND 25 PR TELECOM

CABLE FIBER FROM NEW 5B IT ROOM TO MAIN

SERVER ROOM FG104 ON GROUND FLOOR.

05 TERMINATE COPPER ON 110 BLOCK.

COORDINATE WITH COR.

1/2" THREADED

SUPPORT RODS

@ 48" O.C.

C-CLAMP TO

BLOCKING

CABLE RUNWAY SB-17

SEE PLAN FOR

LOCATION

+8'-0"

+9'-6"

1/2' THREADED

SUPPORT RODS

@ 48" O.C.

C-CLAMP TO

BLOCKING

CABLE RUNWAY

SB-17 SEE PLAN

FOR LOCATION

C-CLAMP

NUT

MIN. 3" EMBEDMENT

BOLT TO CEILING JOIST

(PROVIDE BLOCKING AS

NECESSARY)

48" MAX. CABLE TRAY WIDTH

CABLE RUNWAY

EXTENSION

CLAMP

CABLE

RUNWAY

RUNWAY END

SUPPORT (SB-163)

AUXILLARY

STRINGER TUBE OR

CABLE RUNWAY

"C" CLAMP

AND HANGER

@ 4'-0" O.C.

CORNER

BRACKET

CABLE RUNWAY

FINISHED FLOOR

CR

ES DC

RX

NOTE:

1. ELECTRICAL CONTRACTOR SHALL

PROVIDE CONDUIT, BOXES, AND

SUPPORTS. COORDINATE AND VERIFY

LOCATIONS WITH OWNER.

2. PROVIDE CABLING PER

MANUFACTURER'S RECOMMENDATION.

ELECTRONIC LOCKING

MECHANISM

3/4" C

FINISHED CEILING

8"x8"x4" HINGED

CONTROLLER BOX

MOUNTED ABOVE CEILING

1" C

TO ACCESS CONTROL

SYSTEM PANEL (PACS),

VERIFY LOCATION

CARD READER IN SINGLE

GANG BOX, OR AS REQUIRED

BY MANUFACTURER, FACING

TOWARDS UNSECURED SIDE

OF DOOR

REQUEST FOR EXIT

SENSOR(S), FACING

TOWARDS SECURED SIDE OF

DOOR

EL

1/2" C3/4" C

ELECTRONICALLY

OPERATED LATCH

STRIKE

DOOR CONTACT

3/4" C

EEB

PACS

CONTROLLER

PACS

POWER

SUPPLY

PACS

CONTROLLER

PACS

POWER

SUPPLY

J

PACS 8"x8"x6' HINGED TROUGH

8'x8'x3/4" FIRE RATED PLYWOOD

PACS 6"x6"x6'

HINGED VERTICAL

TROUGH

FIRE ALARM

ADDRESSABLE

RELAY OUTPUT

MODULE

1" CONDUIT FROM

EACH PACS DOOR

1" CONDUIT FROM

EACH PACS DOOR

NOTE:

1.CONTRACTOR SHALL COORDINATE SYSTEM

PROGRAMMING AND FINAL CONNECTION

WITH.

20A, 110V, (1) 4S-JBOX

16" AFF IN CENTER OF

PLYWOOD

TO ROAMING

SYSTEM (2/TK503)

ROBOT

INTERLOCK W/

AETHON ROBOT

TO OPEN

DOORS.

18" CABLE LADDER

CORNER SUPPORT

NOTE:

SCHEMATIC SAMPLE LADDER SYSTEM

SB-163

SB-162

3/8" x 1-1/2"

RUNWAY

STRINGER

(1) 4 PR UTP

DATA CABLE, YELOW,

GREEN OR GRAY

(1) 4 PR UTP

TELEPHONE

CABLE, WHITE

1/2" HIGH BLACK LETTERS ON

CLEAR BACKGROUND,

PANDUIT OR EQUAL ON

PERMANENT LABEL, TYPICAL.

XXX

XXX

B B

T T

BLANK

SINGLE GANG COVER

PLATE WITH 6 OUTLETS

(TYPICAL). LOCATIONS AS

SHOWN ON PLANS

TELE/DATA (TYP.) ( 4)

BLANK

(1) 4 PR UTP

TELEPHONE

CABLE, WHITE

1/2" HIGH BLACK LETTERS ON

CLEAR BACKGROUND,

PANDUIT OR EQUAL ON

PERMANENT LABEL, TYPICAL.

XXX

XXX

B B

T B

BLANK

SINGLE GANG

COVER PLATE WITH

6 OUTLETS

(TYPICAL).

LOCATIONS AS

SHOWN ON PLANS

TELE/DATA (TYP.) ( 2)

(1) 4 PR UTP

TELEPHONE

CABLE, WHITE

C C

(1) 4 PR UTP

DATA CABLE, BLUE

C C

(1) 4 PR UTP

DATA CABLE, YELLOW,

GREEN OR GRAY

(1) 4 PR UTP

DATA CABLE, YELLOW,

GREEN OR GREY

BLANK

NOTE: ALL EQUIPMENT AND INSTALLATION SHALL

BE APPROVED BY VAMC IT DEPARTMENT.

BLANK

XXX

XXX

B B

T

TELEPHONE (TYP.) ( T)

BLANK

BB

B

WHITE (TO TELEPHONE

CABINET IN IT ROOM)

BLANK

NOTES:

1. ALL CONNECTIONS TO THE TMGB AND TGB SHALL BE MADE WITH

COMPRESSION STYLE LONG BARREL CONNECTORS ON THE

CONDUCTOR AND 2-LUG BOLTED CONNECTIONS TO THE

GROUNDING BARS. CONNECTIONS TO STEEL SHALL BE WITH

SILICON BRONZE HARDWARE. CONNECTION TO SLEEVES OR

CONDUITS SHALL BE BY AN APPROVED GROUNDING BUSHING.

2. LOCATE TMGB AND TGB ON THE LEFT OF THE TTB AND 16" AFF.

3. ALL CONDUCTORS USED FOR GROUNDING SHALL BE MARKED AT

CONNECTION POINT AND EVERY TEN FEET (10') THEREAFTER

WITH A LABEL IDENTIFYING IT AS THE TELECOMMUNICATIONS

GROUNDING BACKBONE (TBB). USE PANDUIT #LTYK OR

APPROVED EQUIVALENT.

4. PROVIDE 4"H x 20"L x 1/4"W TMGB.

5. PROVIDE 2"H x 24"L x 1/4"W TGB.

6. CONTRACTOR SHALL CLEAN THE BUS BAR AND APPLY ANTI-

OXIDANT PRIOR TO FASTENING THE CONNECTORS TO THE BUS

BAR.

7. ALL COPPER BACKBONE CABLING SHALL MEET THE

REQUIREMENTS OF TIA/EIA 568-C FOR RISER CABLE.

C O

M M

E

Q U

IP

M

E N

T /R

A C

K S

M E

T A

L S

L E

E V

E S

(W

IT

H

IN

C O

M M

R

M

S T

R U

C T

U R

A L S

T E

E L

B A

S K

E T

T R

A Y

G R

O U

N D

L O

O P

MAIN

TMGB

TR-#1

TGB

COMM. EQUIPMENT/RACKS

ELECTRICAL PANEL

STRUCTURAL STEEL

CABLE TRAY

TR-#2

TGB

COMM. EQUIPMENT/RACKS

ELECTRICAL PANEL

STRUCTURAL STEEL

CABLE TRAY

PROVIDE 6 AWG

CONDUCTOR, EACH

RUN

PROVIDE 1/0 AWG CONDUCTOR

TO TGB FOR EACH TR

PROVIDE 2/0 AWG CONDUCTOR

TO GROUND RING FOR

ELECTRICAL SYSTEM

PROVIDE 1/0 AWG

CONDUCTOR TO

TGB FOR EACH TR

E L E

C T

R

IC

A L P

A N

E L

FINISHED FLOOR

MOUNTING HEIGHT AS

SHOWN IN DRAWINGS

4-11/16" SQ. BY 2-1/2"

DEEP BOX WITH SINGLE

GANG 5/8" TILE RING.

1-1/4" CONDUIT WITH

COMMUNICATIONS WIRING

WALL

CORRIDORROOM

6"

NYLON BUSHING

COORDINATE WITH DUCTWORK

EXTEND CONDUIT TO ABOVE

FINISHED ACCESSABLE

CEILING IN CORRIDOR TO

CABLE TRAY UNLESS NOTED

OTHERWISE.

SUSPENDED LAY-IN

CEILING

CABLE TRAY

(SECURE) CLINICAL PATIENT

WIRELESS ACCESS POINT

SURFACE BISCUIT, GREEN CABLE,

GREEN JACK (TO OIT). CABLE

SHALL BE RUN IN CONDUIT WITH

MINIMUM SIZE OF 3/4".

(UNSECURE) PATIENT

WIRELESS ACCESS POINT

SURFACE BISCUIT, ORANGE

CABLE, ORANGE JACK (TO BIO

MED). CABLE SHALL BE RUN

IN THE CABLE TRAY.

NOTE: CABLE COLOR SHALL BE ORANGE

10"

4"

1/4"

3/16" DIAMETER, TYP. FOR 6

1/4" DIAMETER, TYP. FOR 12

TMGB & TGB

1 TELECOM ROOM OPPER GOUND BAR, 1/4" x 4" x 10", CHATSWORTH PRODUCTS

INC. NO. 10622-010 OR APPROVED EQUAL BY ERICO OR HARGER GOUNDING

PRODUCTS. HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION.

STANDOFF BRACKET ASSEMBLY WITH INSULATORS, TYP. FOR 2.

LOCK WASHER, TYPICAL FOR 2.

ANCHOR BOLTS, TYPICAL FOR 2.

A CONTINUOUS #3/0 GREEN INSULATED CONDUCTOR SHALL BE RUN

FROM SERVICE GROUND AT MAIN SWITCHBOARD (MSB) TO MAIN TELECOM

ROOM GROUND BAR (TMGB).

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:1

:1

P

M

TK501

TECHNOLOGY DETAILS

7 9RSB JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

Scale: N.T.S.

CABLE LADDER - ELEVATION

Scale: N.T.S.

CABLE LADDER - PLAN VIEW

Scale: N.T.S.

SINGLE DOOR CARD ACCESS - STANDARD HARDWARE

Scale: N.T.S.

DOOR CONTROLLER ELEVATION

Scale: N.T.S.

CABLE LADDER CORNER

Scale: N.T.S.

CABLE RUNWAY RADIUS DRIP DETAIL

Scale: N.T.S.

CABLE LADDER - VERTICAL LADDER

Scale: N.T.S.

TELECOMMUNICATIONS FACEPLATE

Scale: N.T.S.

TELECOMMUNICATIONS GROUNDING

Scale: N.T.S.

TELECOMMUNICATIONS OUTLET INSTALLATION

Scale: N.T.S.

WIRELESS ACCESS POINTS

Scale: 3/16" = 1'-0"

TELECOM & MAIN ELECTRICAL GROUND BAR

FIFTH FLOOR

NEW IT

RACK

RM B5003A

NEW 24 STRAND MULTIMODE 50

MICRON TIGHT BUFFERED

ARMORED FIBER (OM4) AND

NEW 1-25 PR CAT5E CABLE

FOURTH FLOOR

THIRD FLOOR

SECOND FLOOR

FIRST FLOOR

GROUND FLOOR

NEW 24 PORT WALL MOUNTED

FIBER OPTIC PATCH PANEL.

NEW CORE AND SLEEVE.

SEAL AFTER WORK IS DONE.

TYPICAL EACH FLOOR.

PROVIDE NEW 24 PORT

FIBER PATCH PANEL WITH

4-6 PORT COUPLERS AND

110 BLOCKS FOR NEW 25

PR TELECOM CABLE.

COORDINATE WITH COR.

SERVER ROOM

FG104

TO TELECOM

GROUNDING BUS

TO OIT ROOM, 12 STRAND MM

FIBER (OM4) 4-4 PR UTP

24 PORT P.O.E.

SWITCH(ES)

WIRE MANAGEMENT

WIRE MANAGEMENT

FIBER OPTIC

PATCH PANEL

SPACE

COPPER PATCH

PANEL(S)

WIRE MANAGEMENT

UPS/BATTERY

TO SECURITY

OFFICE (VERIFY

LOCATION)

STANDARD FIXED

WALL OR DOME

CAMERA (TYPICAL)

NOTE:

1. CCTV CABINET SHALL BE WALL MOUNTED HINGED 18 U'S,

26"Wx30"Dx36"H. FRONT GLASS DOOR. QUIET FAN WITH

FILTER. POWERSTRIP SURGE PROTECTION WITH FILTER.

GROUND BUS BAR, SHELVES.

2. ALL CABLING SHALL BE IN A MINIMUM 3/4" CONDUIT.

3. CCTV CABLE COLOR SHALL BE VIOLET.

4. 4 PR UTP IN CONDUIT (<295')

5. FIBER IN CONDUIT (>295')

20A, 120V

FINISHED FLOOR

TYPICAL DATA RACK DETAIL NOTES:

1. 24 PORT FIBER OPTIC WALL MOUNTED PATCH

PANEL WITH COUPLERS.

2. HORIZONTAL WIRE MANAGEMENT (1U).

3. 48 PORT COPPER PATCH PANEL, DATA.

4. UNINTERRUPTIBLE POWER SUPPLY (3000 VA).

5. POWER RECEPTACLE, SEE ELECTRICAL

DRAWINGS.

6. 48 PORT COPPER PATCH PANEL, DATA.

7. NEW FLOOR HINGED EQUIPMENT CABINET

WITH POWER STRIP, AC POWER LINE SURGE

PROTECTOR AND FILTER, GROUND BUS,

GROUND TERMINAL, AND VERTICAL &

HORIZONTAL WIRE MANAGEMENT.

8. VERTICAL POWER STRIP.

9. VERTICAL GROUND BUS.

10. VERTICAL WIRE MANAGEMENT, IF RACKS

ARE GANGABLE THEN PROVIDEONLY ONE

VERTICAL WIRE MANAGEMENT BETWEEN

THEM.

11. 48 PORT COPPER PATCH PANEL FOR WAP.

12. SPACE FOR VA FURNISHED EQUIPMENT.

13. FIBER OPTIC PATCH CORDS

22"

10 10

2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48

1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8

2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48

1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8

2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48

1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8

2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48

1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8

2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48

1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8

2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48

1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8

2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48

1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8

2625 27 28 29 30 31 32 3433 35 36 37 38 39 40 4241 43 44 45 46 47 48

1817 19 20 21 22 23 24109 11 12 13 14 15 1621 3 4 5 6 7 8

WALL MOUNTED

FIBER OPTIC PATCH

PANEL

TYPICAL NURSE CALL SYSTEM RISER NOTES:

1. NURSE CALL CABINET - RAULAND BORG RS TO MATCH EXISTING.

2. NURSE CALL CABLE, 4 PR CAT 6 PER MANUFACTURER'S

RECOMMENDATIONS.

3. NURSE CALL POWER CABLE, 2-12 AWG, 1-12 EG IN 3/4" CONDUIT OR

PER MANUFACTURER'S RECOMMENDATIONS. REQUIRED ON FIRST DOME

LIGHT OR DOMELESS CONTROLLER OF EVERY SIX CONSECUTIVE

DOME LIGHTS OR DOMELESS CONTROLLERS ON CHAIN.

4. LIGHTING CONTROL CABLE, 3-20 AWG IN 3/4" CONDUIT OR PER

MANUFACTURER'S RECOMMENDATIONS.

5. NURSE CALL MULTI-COLOR DOME LIGHT.

6. NURSE CALL PATIENT BED STATION, SINGLE OR DUAL (SEE

DRAWINGS FOR CONFIGURATION). IF CODE BLUE/CODE WHITE ARE

INTEGRATED INTO BED STATION, EXTERNAL DEVICES FOR CODE

BLUE/CODE WHITE ARE NOT REQUIRED AT THAT STATION.

7. NURSE CALL PATIENT BED INTERFACE RECEPTACLE (VERIFY BED

TYPE).

8. NURSE CALL TOILET ROOM PULL CORD STATION.

9. NURSE CALL SHOWER PULL CORD STATION.

10. NURSE CALL MASTER CONSOLE STATION (TOUCH SCREEN).

11. NURSE CALL DUTY/STAFF STATION (SEE DRAWINGS FOR MORE

INFORMATION).

12. NURSE CALL DOMELESS CONTROLLER (SEE DRAWINGS FOR MORE

INFORMATION).

13. TO NURSE CALL CABINET.

14. NURSE CALL CODE STATION (SEE DRAWINGS FOR MORE INFO). IF

CODE STATIONS ARE INTEGRATED INTO BED STATION, EXTERNAL

CODE STATION DEVICES ARE NOT REQUIRED AT THAT BED STATION.

15. NURSE CALL PILLOW SPEAKER AND CONTROLS (GET WELL TV,

LIGHTING, ETC).

16. PATIENT ROOM TV (GOVERNMENT FURNISHED AND INSTALLED).

17. PATIENT ROOM LIGHTING.

TO NEXT

DOME LIGHT

TO TELECOM

ROOM

NURSE CALL

CABINET

TYPICAL PATIENT BATHROOMTYPICAL PATIENT BED

D

TV

5 N12 N D

TO GROUNDING

BUS

GENERAL NURSE CALL SYSTEM RISER NOTES:

A. PROVIDE A COMPLETE RACEWAY SYSTEM

FOR THE NURSE CALL SYSTEM IF CABLE

TRAY IS NOT AVAILABLE.

B. CONTRACTOR SHALL VERIFY RACEWAY

REQUIREMENT WITH THE NURSE CALL

SYSTEM MANUFACTURERS.

S

B

P E E

M

DUPLEX RECEPTACLE (1 - FOR

DATA)

DATA RECEPTACLE (1 -

FOR TELEMETRY)JUNCTION BOX FOR WALL SCONCE

FLOOR ELEVATION

DATA RECEPTACLE(2)

DUPLEX RECEPTACLE

DATA RECEPTACLE (2)

DUPLEX RECEPTACLE

37-PIN CONNECTOR FOR PATIENT

BED

NURSE CALL STAFF/PATIENT

STATION

CEILING ELEVATION

DUPLEX RECEPTACLE

DATA RECEPTACLE (2)

DUPLEX RECEPTACLE

NOTES:

1. REFERENCE ARCHITECTURAL PLANS FOR MORE INFORMATION.

J J J

4 4

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:1

:1

P

M

TK502

TECHNOLOGY DETAILS

8 9RSB JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

Scale: N.T.S.

LOCAL AREA NETWORK RISER

Scale: N.T.S.

CCTV SYSTEM RISER DIAGRAM

Scale: N.T.S.

DATA RACK ELEVATION - TYPICAL

Scale: N.T.S.

NURSE CALL RISER DIAGRAM

Scale: N.T.S.

TYPICAL PATIENT BED SERVICE WALL ELEVATION

1' - 0"1' - 0"

LAY-IN CEILING

NOTES:

1. BUILDING STRUCTURE.

2. UNISTRUT.

3. 3/8" THREADED ROD WITH BUSHING AND NUTS.

4. CABLE TRAY.

5. GROUND LUG.

6. GROUND CABLE TO TTG.

7. PROVIDE MINIMUM CLEARANCE PER TIA/EIA 569-B.

TO GROUNDING BUS

LOCATOR SYSTEM

NW NWNWNW

TO DATA NETWORK

4 PR UTP

CEILING INFRARED

LOCATOR SENSOR

(TYPICAL)

MONITOR

PC

LOCATOR

SYSTEM PC

NOTE:

• ELECTRICAL CONTRACTOR SHALL

PROVIDE CONDUIT, BOXES,

SUPPORTS, AND CABLING. CABLING

SHALL BE PER MANUFACTURER'S

RECOMMENDATION. CONDUITS

SHALL BE A MINIMUM DIAMETER OF

3/4".

• NEW SYSTEM TO MATCH THE

EXISTING CENTRAK SYSTEM.

4 PR UTP

(TYPICAL)

(MOUNT ON TTB

NEAR NURSE CALL

CABINET)

TO GROUNDING BUS

ROAMING SYSTEM

(WANDER GUARD)

L

CEILING RECEIVER (TYPICAL)

MONITOR

PC

LOCATOR

SYSTEM PC

NOTE:

• ELECTRICAL CONTRACTOR SHALL PROVIDE

CONDUIT, BOXES, SUPPORTS, AND CABLING.

CABLING SHALL BE PER MANUFACTURER'S

RECOMMENDATION. CONDUITS SHALL BE A

MINIMUM DIAMETER OF 3/4".

• PROVIDE CEILING RECIEVER FOR FULL 5B

COVERAGE.

• PROVIDE SPARE NECK TRANSMITTERS.

• NEW SYSTEM TO MATCH THE EXISTING

STANLEY'S SYSTEM. (BUTCH'S REPAIR

SERVICES, SIDNEY (BUTCH) FLAKE 434-568-7388)

• TIE ROAMING SYSTEM IN WITH MAGNETIC

LOCKS AT EXITS AND PROVIDE

INTERCONNECTION WITH FIRE ALARM SYSTEM

L L L

NECK OR BELT

TRANSMITTER

4 PR UTP

(TYPICAL)

RK

DOOR RESET KEYPAD

120V

4 PR UTB TO ROOM B6011 ON 6TH

FLOOR, ELECTRICAL ROOM.

TO PACS EQUIPMENT

TO FIRE ALARM

K

LOCKDOWN

SWITCH AT

NURSE

STATION

MAGLOCK

DOOR

CONTACT

NURSE CALL

INTERFACE WITH

PATIENT BED (BLUE)

(1) 4 PR UTP FOR

MATV (VIOLET)

1/2" HIGH BLACK LETTERS

ON CLEAR BACKGROUND,

PANDUIT OR EQUAL ON

PERMANENT LABEL,

TYPICAL.

XXX

XXX

C B

V

BLANK

(1) RG-6 CABLE

FOR MATV

SINGLE GANG

COVER PLATE WITH

4 OUTLETS

(TYPICAL).

LOCATIONS AS

SHOWN ON PLANS

TV/MATV (TYP.) ( )

EXISTING

CABINET

WITH MATV

EQUIPMENT

5TH FLOOR

PATIENT ROOM TV

(TYPICAL)

RG-6 AND 4 PR UTP

(TYPICAL)

NOTES:

1. ALL CONDUIT SHALL RUN TO THE CABLE TRAY.

2. MINIMUM CONDUIT SIZE IS 3/4" DIAMETER.

3. PROVIDE INTERFACE TO NURSE CALL.

TO GROUNDING BUS

SSS

RGG AND 4 PRU UTP

N.C. CAB

PACS

EQUIP

TGB

2'-0"

6"

2'-0"

2'-6"

FLOOR

CCTV

EQUIP

TELEMETRY

RTLS-EQ

ROAMING EQ.

3 KVA UPS

84"

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:1

:1

P

M

TK503

TECHNOLOGY DETAILS

9 9RSB JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

Scale: N.T.S.

CABLE TRAY ELEVATION - CORRIDOR

Scale: N.T.S.

REALTIME LOCATOR SYSTEM (RTLS) RISER DIAGRAM

Scale: N.T.S.

ROAMING SYSTEM RISER DIAGRAM

Scale: N.T.S.

TV OUTLET FACEPLATE

Scale: N.T.S.

MATV SYSTEM RISER DIAGRAM

Scale: 1/2" = 1'-0"

BIO MED EAST ELEVATION

Scale: 1/2" = 1'-0"

BIO MED WEST ELEVATION

GENERAL FIRE ALARM NOTES

1. PROVIDE FIRE ALARM SYSTEM AND COMPONENTS COMPLYING WITH:

A. LATEST EDITION OF NFPA 13- STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS.

B. LATEST EDITION OF NFPA 14- STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE

SYSTEM.

C. LATEST EDITION OF NFPA 20- STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE

PROTECTION.

D. LATEST EDITION OF NFPA 70 NATIONAL ELECTRICAL CODE.

E. LATEST EDITION OF NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE.

F. LATEST EDITION OF NFPA 90A STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND

VENTILATING SYSTEMS.

G. LATEST EDITION OF NFPA 101 LIFE SAFETY CODE.

H. LATEST EDITION OF VA FIRE PROTECTION DESIGN MANUAL.

I. LATEST EDITION OF ANSI S3.41 AUDIBLE EMERGENCY EVACUATION SIGNAL.

J. LATEST EDITION OF NFPA 88A STANDARD FOR PARKING STRUCTURES.

1. FIRE ALARM SYSTEM SHALL COMPLY WITH FACTORY MUTUAL RESEARCH CORPORATION (FM).

2. PROVIDE FIRE ALARM WIRING IN CONDUIT, FACTORY PAINTED RED.

3. BEFORE STARTING WORK, TEST EXISTING FIRE ALARM SYSTEM IN WORK AREA AND ADJACENT AREAS.

4. NOTIFY COR REGARDING DEFICIENCIES AND NON-OPERATING COMPONENTS. VA WILL MAKE REPAIRS.

5. WHEN WORK IS COMPLETE, TEST EXISTING FIRE ALARM SYSTEM IN WORK AREA AND ADJACENT AREAS.

6. MAKE REPAIRS TO RESOLVE INCORRECT SYSTEM OPERATIONS AT NO ADDITIONAL COST.

7. THE FIRE ALARM SYSTEM VENDOR/CONTRACTOR SHALL TERMINATE, TEST AND PROGRAM ALL NEW FIRE

ALARM DEVICES. COORDINATE WITH COR.

8. CONNECT SPRINKLER SYSTEM SUPERVISORY DEVICES TO THE FIRE ALARM SYSTEM. COORDINATE

LOCATION WITH THE SPRINKLER CONTRACTOR.

9. CONNECT ALL ELECTROMAGNETIC DOOR HOLD OPEN DEVICES TO THE FIRE ALARM SYSTEM. COORDINATE

WITH THE DOOR HARDWARE CONTRACTOR.

10. PROVIDE RELAY CONTROL MODULES FOR PACS, COORDINATE WITH PHYSICAL ACCESS CONTROL SYSTEM

(PACS), CONTRACTOR AND COR.

11. PROVIDE RELAY CONTROL MODULES FOR COOKING POWER SUPPLY SHUT OFF.

12. PROVIDE RELAY CONTROL MODULES FOR KITCHEN HOOD FIRE SUPPRESSION SYSTEM.

13. SYNC NEW STROBES WITH THE EXISTING STROBES ON THE SAME FLOOR.

FIRE ALARM SYMBOL LEGEND

FIRE ALARM PULL STATION

SYMBOL HEIGHT DESCRIPTION

ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.

TOP: HEIGHT TO TOP OF DEVICE

ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.

F

F

S

FIRE ALARM SPEAKER

FIRE ALARM STROBE

FIRE ALARM PULL SPEAKER AND STROBE

FIRE ALARM DOOR OPEN HOLDER

FIRE ALARM PHOTOELECTRIC SMOKE DETECTOR

FIRE ALARM CEILING MOUNTED SPEAKER

P

FIRE ALARM DUCT SMOKE DETECTOR

FIRE ALARM HEAT DETECTOR

48"

90"

90"

90"

FIRE ALARM PANEL

FIRE ALARM NAC PANEL

FIRE ALARM ANNUNCIATOR PANEL

FLOW SWITCH

FAP

NAC

FAAP

TAMPER SWITCH

POST INDICATOR VALVEPIV

REMOTE LIGHT/TEST SWITCH FOR DUCT DETECTORS

F FIRE ALARM BELL90"

XX - CANDELA

XX - CANDELA

XX - WATTAGEF

S

F

S

H

Fs

Ts

NOTES:

1. FIRE ALARM SYSTEM SHALL BE INTERCONNECTED WITH ACCESS CONTROL SYSTEM

TO ALLOW EGRESS DURING ALARM CONDITIONS. COORDINATE BETWEEN ACCESS

CONTROL SYSTEM AND FIRE ALARM SYSTEM MANUFACTURERS.

2. ALL FIRE ALARM WIRING SHALL BE IN FACTORY PAINTED "RED" EMT CONDUIT.

3. ALL WIRING SHALL BE AS RECOMMENDED BY MANUFACTURER.

4. PROVIDE POWER SUPPLY AND/OR NAC (NOTIFICATION APPLIANCE CIRCUIT) PANEL

AS REQUIRED FOR ADDITIONAL DEVICES (VERIFY ADEQUATE SPACE CAPACITY).

5. PROVIDE POWER AMPLIFIERS FOR ALL SPEAKERS.

6. REVISED FIRE ALARM SYSTEM SHALL BE AN EXTENSION OF THE EXISTING SIMPLEX

FIRE ALARM SYSTEM. SEE AS-BUILT DOCUMENTATION FOR FIFTH FLOOR BUILDING 1.

FS TS

TO FIELD

VERIFY CIRCUIT

INDICATING

APPLIANCES

TO ADDITIONAL FLOW

AND TAMPER

SWITCHES

TO

ADDITIONAL

INITIATING

DEVICES

EXISTING FIRE

ALARM

TERMINAL

CABINET

EXISTING SPRINKLER SYSTEM DEVICES

S S S TO EXISTING FIRE

ALARM SPEAKERS

FF F

F

RFOR PACS

R

(EX)

(EX)

R

TO ROAM ALERT

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:1

:4

P

M

FA001

FIRE ALARM GENERAL INFORMATION

1 3RSB JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

Scale: N.T.S.

FIRE ALARM RISER

N

R

A

N

046636

E

E N

I

G

H

K

I

A

W

O

N

A

T

R

F

SEAL

R

P

O

O

I

SS

O E

H

RC

A

I

L

A

N

L

E

N

C

I

M

H

E

A

F

S

FA

F

F S

FA

F

F

F

F

F

F

F

F F FF

LI

M

IT

O

F P

R O

JE

C

T S

C O

P E

L L

M M

N N

P P

Q Q

R R

R.1 R.1

5.1

5.1

8 9

13 14

14 15

SS

TT

R

R

R

R

R

R

R R

R RR

R

R

Ts Fs

3 4

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:1

:5

P

M

FA100

FIFTH FLOOR FIRE ALARM DEMOLITION

PLAN

2 3RSB JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

Scale: 1/8" = 1'-0"

FIFTH FLOOR FIRE ALARM DEMOLITION PLAN 0 4 8 16

NORTH

TRUE

A. COORDINATE ALL WORK WITH COR.

B. EXISTING FIRE ALARM SYSTEM OUTSIDE

AREAS OF WORK SHALL REMAIN ACTIVE

DURING CONSTRUCTION.

C. RETAIN AND REUSE DEVICES AS NOTED.

REUSE AND/OR REPLACE RACEWAYS AND

WIRING BACK TO TERMINAL CABINETS AS

REQUIRED.

D. SEE SIMPLEX/GRINNELL SHEET FA107

PROJECT #09-423425/945390101.

COORDINATE WITH COR.

E. ABANDONED CONDUIT/BOXES SHALL HAVE

ALL ELECTRICAL WIRING REMOVED

COMPLETELY AND NOT JUST MADE "SAFE".

CONDUIT/BOXES SHALL BE REMOVED

WHERE PRACTICAL WITHOUT CREATING

ADDITIONAL DEMOLITION WORK FOR

OTHER TRADES. CIRCUITS SUPPLYING

EQUIPMENT WHICH IS REMOVED UNDER

THE CONTRACT DOCUMENTS FOR ANY

DIVISION SHALL, FOR THE PURPOSES OF

THIS NOTE, BE CONSIDERED

"ABANDONED".

F. WHERE CONDUIT IS REMOVED FROM AN

EXISTING RATED ASSEMBLY NOT SUBJECT

TO DEMOLITION, THE REMAINING

PENETRATION SHALL BE

PATCHED/REPAIRED TO MAINTAIN THE

RATING OF THE ASSEMBLY.

G. DEMOLITIONS SHALL INCLUDE BUT NOT BE

LIMITED TO THOSE DEVICES AND OR

SYSTEMS NOTED. COORDINATE WITH

ARCHITECTURAL AND MECHANICAL

DEMOLITION PLANS FOR WORK SCOPE.

FIELD VERIFY EXISTING CIRCUITING.

HEAVIER LINE WEIGHT AND HATCHING

INDICATE DEMOLITION WORK. LIGHTER

LINE WEIGHT INDICATES EXISTING TO

REMAIN, VERIFY IN FIELD.

H. OWNER HAS FIRST RIGHT OF REFUSAL TO

ALL DEMOLITION ITEMS INCLUDING BUT

NOT LIMITED TO SMOKE/FIRE ALARM

DEVICES, AND ALL LIGHT FIXTURES, LAMPS

OR RELATED ASSEMBLIES. ANY ITEMS NOT

IDENTIFIED BY OWNER TO BE SAVED

SHALL BE LEGALLY DISPOSED OF IN

ACCORDANCE WITH STATE AND FEDERAL

REGULATIONS.

I. COORDINATE NOTIFICATION APPLIANCE

CIRCUITS AT THE DEMO AREAS.

1 WHERE NOTED (R), FIELD VERIFY EXISTING

FIRE ALARM CIRCUIT. EXTEND/RELOCATE TO

NEW LOCATION. FIELD VERIFY WITH EXISTING

AS-BUILT DOCUMENTATION.

2 EXISTING FLOW/TAMPER SWITCHES (FIRE

PROTECTION RISER) TO REMAIN AND BE

REUSED.

3 TAMPER SWITCH. EXISTING TO REMAIN.

CIRCUITED FROM M3-117.

4 FLOW SWITCH. EXISTING TO REMAIN.

CIRUITED FROM M3-118.

F S

F

F

F

F

F

F

F

S

F

S

F

S

F

F

F A

P

S

FA

S

FA

S

FA

S

FA

S

FA

S

FA

S

FA

S

FA

S

FA

F

F

F

F

LI

M

IT

O

F P

R O

JE

C

T S

C O

P E

PATIENT RM

B5008

CARE STATION

B5009

PATIENT RM

B5010

PATIENT RM

B5011

PATIENT RM, BARIATRIC

B5012

LOCKER

B5014

PATIENT RM

B5016

SOILED UTILITY

B5018

STAFF LOUNGE

B5015

CLEAN SUPPLY

B5019

ALCOVE

B5020

PATIENT RM

B5021

PATIENT RM

B5022 PATIENT RM

B5024

PATIENT RM

B5025

PASSAGE

B5041

NOUR

B5026

MEDS

B5027

BATH

B5007A

CORRIDOR

B5040

BATH

B5008A

BATH

B5010A

BATH

B5011A

BATH

B5016A

BATH

B5024A

BATH

B5025A

BATH

B5021A

BATH

B5022A

STAIR

B5050

STAFF TLT

B5014A

PATIENT RM, ISOLATION

B5028BATH

B5028A

ANTE

B5028B

PATIENT RM, ISOLATION

B5029

BATH

B5029A

ANTE

B5029B

PATIENT RM, BARIATRIC

B5007

CARE STATION

B5005

EQUIP

B5004

BATH

B5012A

CARE STATION

B5013

CARE STATION

B5023

NURSE MGR OFFICE

B5030

EQUIP

B5017

TEAM WORK ROOM

B5031

OIT

B5003A

ELEC

B5017A

L L

M M

N N

P P

Q Q

R R

R.1 R.1

5.1

5.1

8 9

13 14

14 15

SS

TT

R R R R

SP104

R

SP104

R

SP104

R

SP104 SP101

R

SP101 MS113 MS112

R

SP104

R

MS115

SP104

N

N

N N

N

N N

N

N

N E M3116

02 02

Ts Fs

04 05

N

R M3-114

FIRE ALARM

ZONE 5B

R R

R.1 R.1

5.1

5.1

8 9

SS

TT

J

TYP - EX FA

DEVICE MAINTAIN

SERVICE TO EXISTING

FA SYSTEM

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/1

/2

:3

:2

A

M

FA101

FIFTH FLOOR FIRE ALARM PLAN

3 3RSB JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

Scale: 1/8" = 1'-0"

FIFTH FLOOR FIRE ALARM PLAN 0 4 8 16

NORTH

TRUE

01 EXISTING SIMPLEX FIRE ALARM TERMINAL

CABINET. CIRCUIT NEW FIRE ALARM DEVICES

TO THIS PANEL. COORDINATE WITH COR.

02 (TYP) WHERE NOTED (R) FIRE ALARM DEVICES

ARE EXISTING TO BE RELOCATED AND

REUSED. SEE EXISTING SIMPLEX-GRINNELL

AS-BUILT DOCUMENTATION. REFERENCE

FA100.

03 SEE SHEET GC101 FOR WORK SCOPE

RELATED TO ALTERNATE DEDUCT 1.

04 TAMPER SWITCH. EXISTING TO REMAIN.

CIRCUITED FROM M3-117.

05 FLOW SWITCH. EXISTING TO REMAIN.

CIRUITED FROM M3-118.

A. COORDINATE ALL WORK AND

COMMISSIONING WITH COR.

B. INSURE COMPATIBILITY OF NEW DEVICES

WITH EXISTING SYSTEM, AND TIE NEW

DEVICES INTO EXISTING SYSTEM.

C. TEST EXISTING FIRE ALARM SYSTEM IN

WORK AREAS AND ADJACENT AREAS

PRIOR TO BEGINNING WORK AND AFTER

COMPLETION OF WORK.

D. REPAIR ANY INSUFFICIENCIES FOUND IN

EXISTING SYSTEM.

E. ALARM DEVICES INDICATED ON PLAN ARE

CIRCUITED TO FIRE ALARM CIRCUIT SP104.

F. ABANDONED CONDUIT/BOXES SHALL HAVE

ALL ELECTRICAL WIRING REMOVED

COMPLETELY AND NOT JUST MADE "SAFE".

CONDUIT/BOXES SHALL BE REMOVED

WHERE PRACTICAL WITHOUT CREATING

ADDITIONAL DEMOLITION WORK FOR

OTHER TRADES. CIRCUITS SUPPLYING

EQUIPMENT WHICH IS REMOVED UNDER

THE CONTRACT DOCUMENTS FOR ANY

DIVISION SHALL, FOR THE PURPOSES OF

THIS NOTE, BE CONSIDERED

"ABANDONED".

G. WHERE CONDUIT IS REMOVED FROM AN

EXISTING RATED ASSEMBLY NOT SUBJECT

TO DEMOLITION, THE REMAINING

PENETRATION SHALL BE

PATCHED/REPAIRED TO MAINTAIN THE

RATING OF THE ASSEMBLY.

H. DEMOLITIONS SHALL INCLUDE BUT NOT BE

LIMITED TO THOSE DEVICES AND OR

SYSTEMS NOTED. COORDINATE WITH

ARCHITECTURAL AND MECHANICAL

DEMOLITION PLANS FOR WORK SCOPE.

FIELD VERIFY EXISTING CIRCUITING.

HEAVIER LINE WEIGHT AND HATCHING

INDICATE DEMOLITION WORK. LIGHTER

LINE WEIGHT INDICATES EXISTING TO

REMAIN, VERIFY IN FIELD.

I. OWNER HAS FIRST RIGHT OF REFUSAL TO

ALL DEMOLITION ITEMS INCLUDING BUT

NOT LIMITED TO SMOKE/FIRE ALARM

DEVICES, AND ALL LIGHT FIXTURES, LAMPS

OR RELATED ASSEMBLIES. ANY ITEMS NOT

IDENTIFIED BY OWNER TO BE SAVED

SHALL BE LEGALLY DISPOSED OF IN

ACCORDANCE WITH STATE AND FEDERAL

REGULATIONS.

J. PROVIDE INTERCONNECTION BETWEEN

FIRE ALARM SYSTEM AND ROAM ALERT

SYSTEM. COORDINATE WITH COR.

Scale: 1/8" = 1'-0"

FIFTH FLOOR FIRE ALARM PLAN ALTERNATE DEDUCT 1 0 4 8 16

NORTH

TRUE

TO EXISTING

(EX) FA CIRCUITS

(MS 115M SP104)

VIF

AETHON ROBOT DOOR INTERCONNECTIONS REVISION 08/15/2019

N

R

A

N

046636

E

E N

I

G

H

K

I

A

W

O

N

A

T

R

F

SEAL

R

P

O

O

I

SS

O E

H

RC

A

I

L

A

N

L

E

N

C

I

M

H

E

A

08-TK, FA 100%BD
Sheets
TK001 - TECHNOLOGY GENERAL INFORMATION
TD101 - FIFTH FLOOR TECHNOLOGY DEMOLITION PLAN
TK101 - FIFTH FLOOR TECHNOLOGY PLAN
TK102 - FIFTH FLOOR SYSTEMS PLAN
TK103 - FIFTH FLOOR OVERALL SYSTEMS PLAN
TK104 - GROUND FLOOR TECHNOLOGY ROUTING PLAN
TK501 - TECHNOLOGY DETAILS
TK502 - TECHNOLOGY DETAILS
TK503 - TECHNOLOGY DETAILS
FA001 - FIRE ALARM GENERAL INFORMATION
FA100 - FIFTH FLOOR FIRE ALARM DEMOLITION PLAN
FA101 - FIFTH FLOOR FIRE ALARM PLAN
18-048 AETHON CHANGES EE FA TK
Sheets
EP101 - FIFTH FLOOR POWER PLAN
E-602 - ELECTRICAL SCHEDULES
TK101 - FIFTH FLOOR TECHNOLOGY PLAN
FA101 - FIFTH FLOOR FIRE ALARM PLAN