36C24620R0007-0005004.pdf
PDF Posted
- Attached to
- Inpatient Privacy Renovate 5B
- Solicitation number
- 36C24620R0007
About this file
This notice announces an upcoming solicitation for inpatient privacy renovations at a Department of Veterans Affairs medical center. The solicitation will be for construction services to gut and renovate approximately 8,000 square feet of space on the fifth floor into twelve private patient rooms and ancillary spaces. The estimated construction value is between $1,000,000 to $5,000,000. The solicitation is anticipated to be a total service-disabled veteran owned small business set-aside. The solicitation material will be available on November 7, 2019, with proposals due approximately 45 days later. Site visits for the renovation location can be arranged through the point of contact. Interested vendors should register on the website to receive amendments and notices related to the solicitation.
36C24620R0007 0005 03B-Arch_100_BD.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24620R0007-0011001.pdf | ||
| 36C24620R0007-0011002.pdf | ||
| 36C24620R0007-0011000.docx | DOCX document | |
| 36C24620R0007-0010000.docx | DOCX document | |
| 36C24620R0007-0009000.docx | DOCX document | |
| 36C24620R0007-0008001.pdf | ||
| 36C24620R0007-0008000.docx | DOCX document | |
| 36C24620R0007-0007000.docx | DOCX document | |
| 36C24620R0007-0006004.pdf | ||
| 36C24620R0007-0006006.pdf | ||
| 36C24620R0007-0006000.docx | DOCX document | |
| 36C24620R0007-0006003.pdf | ||
| 36C24620R0007-0006005.pdf | ||
| 36C24620R0007-0006001.pdf | ||
| 36C24620R0007-0006002.pdf | ||
| 36C24620R0007-0005000.docx | DOCX document | |
| 36C24620R0007-0005001.pdf | ||
| 36C24620R0007-0005005.pdf | ||
| 36C24620R0007-0005002.pdf | ||
| 36C24620R0007-0005003.pdf | ||
| 36C24620R0007-0004000.docx | DOCX document | |
| 36C24620R0007-0003000.docx | DOCX document | |
| 36C24620R0007-0003001.pdf | ||
| 36C24620R0007-0002002.pdf | ||
| 36C24620R0007-0002001.docx | DOCX document | |
| 36C24620R0007-0001001.pdf | ||
| 36C24620R0007-023.pdf | ||
| 36C24620R0007-022.docx | DOCX document |
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 REMOVE PARTITIONS AS INDICATED AND PREPARE FOR NEW
WORK. PATCH ADJACENT SURACES AS REQUIRED.
2 REMOVE DOOR AND FRAME.
4 REMOVE PLUMBING FIXTURES AND ACCESSORIES. REFER
TO PLUMBING DRAWINGS.
5 REMOVE CEILINGS AND CEILING MOUNTED FIXTURES AND
PREPARE FOR NEW WORK. PATCH ADJACENT SURFACES AS
REQUIRED. TYP.
6 REMOVE EXISTING IN-WALL HVAC EQUIP. REFER TO
MECHANICAL DRAWINGS.
7 REMOVE GLAZED TILE.
8 CONSTRUCT TEMPORARY PARTITION AND DOOR PRIOR TO
DEMOLITION.
9 REMOVE EXPANSION JOINT COVERS/ASSEMBLIES.
10 REMOVE FLOOR FINISHES (TILE, CARPET, AND RESILIENT
TYPES) AND PREPARE FOR NEW WORK. PATCH ADJACENT
SURFACES AS REQUIRE. TYP.
3 EXTEND TEMPORARY PARTITION AS ADJACENT WALLS ARE
DEMOLISHED TO MAINTAIN ANTEROOM SEPARATION.
1. THE DEMOLITION DRAWINGS FOR ARCHITECTURAL AND ENGINEERING WORK HAVE
BEEN PREPARED USING "AS-DESIGNED" DOCUMENTS PROVIDED BY THE VA. NEITHER THE
VA NOR THE ARCHITECT WARRANT THESE TO BE "AS-BUILT" DOCUMENTS, AND ACTUAL
CONDITIONS MAY VARY. THE DEMOLITION WORK INDICATED IS INTENDED TO SHOW THE
GENERAL SCOPE OF THE DEMOLITION WORK AND IN NO WAY RELIEVES THE CONTRACTOR
FROM PERFORMING ANY AND ALL DEMOLITION REQUIRED TO COMPLETE THE NEW WORK.
2. ALL DEMOLITION WORK SHALL BE PERFORMED WITH DUE CARE AND DILIGENCE SO AS
TO PREVENT THE ARBITRARY DESTRUCTION OR INTERRUPTION OF CONCEALED UTILITIES
WHICH COULD NOT BE PREDETERMINED UNTIL DEMOLITION WAS STARTED. ALL SUCH
DISCOVERIES OF UTILITIES DURING THE DEMOLITION PROCESS WHICH ARE IN A LOCATION
DIFFERENT FROM FLOOR TO FLOOR, ETC., OR ARE UNIDENTIFIED, SHALL BE REPORTED TO
THE COR BEFORE REMOVAL FOR FINAL DISPOSITION.
3. WHEREVER EXISTING EQUIPMENT, PIPING, DUCTS, ETC., ARE REQUIRED TO BE
REMOVED, SUCH REMOVAL SHALL INCLUDE ALL ANCHORS, HANGARS, BRACING,
FOUNDATION, ETC. AFTER REMOVAL, AFFECTED CONSTRUCTION AND SURFACES, SUCH
AS FLOORS ,WALLS, BASES, AND CEILINGS, SHALL BE FINISHED TO MATCH ADJACENT
SURFACES UNLESS OTHERWISE NOTED.
4. NEW WORK SHALL ALIGN WITH EXISTING WORK EXCEPT WHERE OTHERWISE
DIMENSIONED OR DETAILED.
5. WHERE DEMOLITION OR RELATED WORK LEAVES FLOOR SURFACES WITH
IMPERFECTIONS OR NOT LEVEL TO TOLERANCES SPECIFIED FOR NEW WORK, PROVIDE
SELFLEVELING UNDERLAYMENT.
6. WHERE DEMOLITION WORK UNCOVERS OR LEAVES OPENINGS IN PARTITIONS OR
INCOMPLETE PARTITIONS, EXTEND, RESTORE, AND/OR CLOSE OPENING IN PARTITION AS
INDICATED AND/OR AS REQUIRED TO MAINTAIN FIRE RATINGS AND SMOKE BARRIERS.
MATCH EXISTING CONSTRUCTION, U.N.O., WITHIN THE LIMITS AND TOLERANCES FOR
MATERIALS AS SPECIFIED OR RECOMMENDED BY THE MANUFACTURER. REFINISH
SURFACES TO ALIGN FLUSH WITH EXISTING.
7. WHERE DEMOLITION WORK OR RELOCATION OF EXISTING ITEMS LEAVES UNFINISHED
SURFACES AND/OR SUBSTRATES, CUT AND PATCH AS REQUIRED TO RESTORE SUBSTRATE
AND/OR FINISH MATERIAL EVEN AND FLUSH WITH ADJOINING SURFACES. TEXTURE AND
REFINISH TO MATCH EXISTING U.N.O.
8. PROVIDE 2-HOUR RATED TEMPORARY DUST, SIGHT AND SOUND BARRIERS AS REQUIRED
BY APPROVED ICRA PLAN, AND WHEREVER NECESSARY, TO LIMIT THE AMOUNT OF NOISE,
DUST, VISUAL POLLUTION WITHIN AND AROUND THE FACILITY, TO MAINTAIN OCCUPANCY
AND USE OF OCCUPIED AREAS IN THE EXISTING BUILDING. THE EXACT LOCATION AND
QUANTITY OF TEMPORARY BARRIERS IS TO BE COORDINATED WITH COR AND
DETERMINED BY CONSTRUCTION SCHEDULE AND WORK SCHEDULE.
9. WHERE WORK REQUIRES THE REMOVAL OF ACOUSTICAL CEILINGS IN THE LEVEL BELOW
THE PROJECT AREA, CONTRACTOR SHALL CAREFULLY REMOVE THE CEILING AND
REINSTALL THE CEILING TO ORIGINAL CONDITION. IF CEILING COMPONENTS ARE
DAMAGED, THEY SHOULD BE REPLACED BY THE CONTRACTOR.
10. WHERE WORK REQUIRES THE REMOVAL OF GYPSUM OR PLASTER CEILINGS (E.G.
BATHROOMS) IN THE LEVEL BELOW THE PROJECT AREA, CONTRACTOR SHALL REMOVE
EXISTING CEILING OF THAT SPACE AND REPLACE THE EXISTING CEILING WITH A NEW
ACOUSTICAL CEILING SYSTEM (ACT-1).
11. WHERE WORK REQUIRES REMOVAL OF PIPE, CONDUIT, OR DUCT THROUGH A FLOOR
SLAB, CONTRACTOR SHALL PATCH THE PENETRATION THAT SAME DAY TO MAINTAIN THE
FIRE-RATED SLAB ASSEMBLY AND SAFE WORKING CONDITIONS.
1 3 4 5 7 10 11 12
13 14 15 16
5.1 96 8
L
S
T
N
Q
R
M
P
R.1
LI
M
IT
O
F P
R
IM
A R
Y S
C O
P E
7 6 7 6 7 6 7 6 7 6 7 6 7 6 7 6 7 6 7 6
7 6 7 6 7 67 67 67 67 67 6
7 67 67 67 67 67 6
1 1 1
4 4
4 4
AI301
AI301
AI501
AI301
DOOR TAG
ROOM TAG
1 REVISION TAG
FIRE EXTINGUISHER CABINETFEC
FIRE EXTINGUISHERFE
KEYNOTE TAG
SECTION TAG
WALL TAG
A101
SIM
1 DETAIL TAG
INTERIOR ELEVATION TAG
REFERENCE LEGEND
CARD READER
G3.0
A101 1
EXISTING WALL
DEMOLISHED
WALL
NEW WALL
EXISTING DOOR
DEMOLISHED
DOOR
NEW DOOR
A101
CR
Room name
PUSH PLATE DOOR ACTUATORPP
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N A
11389
C
UL
LEN
S. KEEN
C H A R
LOTTE, NORTH
CA
RO
L
IN
A
# SHEET KEY NOTES:
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:2
:1
P M
AD101
FIFTH FLOOR DEMOLITION PLAN
2 17RP/CK CK/AB
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 6/28/2019
BID DOCUMENTS
558-18-150
1/8" = 1'-0"1
FIFTH FLOOR DEMOLITION PLAN
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
0' 8'4' 16'
DocuSign Envelope ID: 2FA44C2E-4408-45AE-A0BD-F22DDA1267A3
7/2/2019
DOOR TAG
ROOM TAG
1 REVISION TAG
FIRE EXTINGUISHER CABINETFEC
FIRE EXTINGUISHERFE
KEYNOTE TAG
SECTION TAG
WALL TAG
A101
SIM
1 DETAIL TAG
INTERIOR ELEVATION TAG
REFERENCE LEGEND
CARD READER
G3.0
A101 1
EXISTING WALL
DEMOLISHED
WALL
NEW WALL
EXISTING DOOR
DEMOLISHED
DOOR
NEW DOOR
A101
CR
Room name
PUSH PLATE DOOR ACTUATORPP
1. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL COMPLY WITH
NFPA 101 AND RELATED NFPA CODES.
2. PENETRATIONS SHALL BE FIRE STOPPED WITH FIRE BARRIER PRODUCTS
AS REQUIRED TO MAINTAIN FIRE RATINGS. INSTALL IN ACCORDANCE WITH
UL ASSEMBLIES AND MANUFACTURER'S INSTRUCTIONS FOR THEIR USE.
PRODUCTS MUST BE APPROVED BY COR PRIOR TO INSTALLATION.
3. SUBMIT SHOP DRAWINGS FOR APPROVAL SHOWING PENETRATIONS,
MATERIALS USED FOR FIRE RATING AND UL ASSEMBLY NO.
4. PROVIDE BLOCKING AT PARTITIONS AS REQUIRED FOR MOUNTING OF
FURNISHED AND NON-FURNISHED WALL-MOUNTED ITEMS.
5. VERIFY THAT CARRIERS TO BE USED FOR WALL MOUNTED SINKS AND
LAVATORIES ARE THE TYPE THAT WILL FIT WITHIN STUD WALLS SHOWN.
CONTACT ARCHITECT IF THERE IS A CONFLICT.
6. PROVIDE SUPPLEMENTAL FRAMING, INSULATION, AND FINISH MATERIALS
AS REQUIRED TO MAINTAIN PARTITION FIRE-RESISTANCE RATING AT
RECESSED ITEMS.
7. CONTRACTOR SHALL ARRANGE AN INSPECTION OF RATED PARTITIONS
WITH THE COR PRIOR TO INSTALLING CEILING.
8. ALL CURRENT APPLICABLE CODES SHALL BE APPLIED TO THIS PROJECT,
INCLUDING:
a. 2018 NFPA 101
b. 2018 NFPA 99
c. 2016 NFPA 13
d. 2016 NFPA 72
1 NEW EXPANSION JOINT COVER ASSEMBLY
2 PROVIDE CONT SHEET METAL BLOCKING FOR OFOI BIN
HANGING SYSTEM FROM 18" AFF TO 6'-6" AFF.
3 EXHAUST DUCT, REF TO MECH DRAWINGS.
4 PROVIDE (4) GUY WIRES ANCHORED TO ROOF TO SECURE
VERTICAL EXHAUST DUCT.
5 DUCT SUPPORT BRACKETS AT 48" OC.
6 PROVIDE 12"X12" ACCESS PANEL FOR CONDENSATE DRAIN
CONNECTION. MOUNT 24" AFF TO TOP.
1 3 4 5 7 10 11 12
13 14 15 16
5.1 96 8
L
S
T
PATIENT RM
B5008
CARE
STATION
B5009
PATIENT RM
B5010
PATIENT RM
B5011
PATIENT RM,
BARIATRIC
B5012
LOCKER
B5014
PATIENT RM
B5016 SOILED
UTILITY
B5018
CLEAN
SUPPLY
B5019
ALCOVE
B5020
PATIENT RM
B5021
PATIENT RM
B5022 PATIENT RM
B5024
PATIENT RM
B5025
PASSAGE
B5041
NOUR
B5026
MEDS
B5027
BATH
B5007A
CORRIDOR
B5040
BATH
B5008A
BATH
B5010A
BATH
B5011A
BATH
B5016A
BATH
B5024A
BATH
B5025A
BATH
B5021A
BATH
B5022A
STAIR
B5050
STAFF TLT
B5014A
PATIENT RM,
ISOLATION
B5028BATH
B5028A
ANTE
B5028B
PATIENT RM,
ISOLATION
B5029
BATH
B5029A
ANTE
B5029B
PATIENT RM,
BARIATRIC
B5007
CARE
STATION
B5005
EQUIP
B5004
BATH
B5012A
CARE
STATION
B5013
CARE
STATION
B5023
NURSE MGR
OFFICE
B5030
EQUIP
B5017
TEAM WORK
ROOM
B5031
FUTURE
PATIENT ROOM
FUTURE
PATIENT ROOM
STAFF
LOUNGE
B5015
N
Q
R
M
P
R.1
AI301
AI301
AI301
OIT
B5003A
AI431 3
ELEC
B5017A
CR CRCRCR CR
CR
B5014
B5014A
B5015 B5016
B5016A
B5012
B5012A
B5011A
B5011 B5010
B5010A
B5019B5018
B5017A
B5017
B5041
B5026
B5020
B5008A
B5008
B5007
B5007A
B5004
B5040
B5003
B5031B5030
B5029
B5029C
B5029B
B5029A
B5028B5028B
B5028C
B5028A
B5027
B5021A
B5021 B5025
B5025A
B5024B5022
B5022A B5024A
AI301
AI431
AI431
AI431 10
AI431
AI401
1______________________
AI401
AI401
AI431 18
AI43115
AI431 20
AI431 21
AI4321
AI4326
AI4325
AI301
Sim
FECFEC
FEC
AI431
AI431
AI431
AI4315
AI431 5
AI431
AI431 24
LI
M
IT
O
F P
R
IM
A R
Y S
C O
P E
AI501
AI501
AI501
PP CR PP
CR
CR
CR
CR BIO
B5003
B5003A
EXISTING ROOF
EXISTING ROOF
EXISTING MECHANICAL PENTHOUSE
EXISTING
STAIR
TOWER
AI301
CR
CRB5050
EXISTING AHU-15
EXISTING MECH EQUIPMENT
EXISTING WALKPAD
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N A
11389
C
UL
LEN
S. KEEN
C H A R
LOTTE, NORTH
CA
RO
L
IN
A
# SHEET KEY NOTES:
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:2
:4
P M
AI101
FIFTH FLOOR PLAN
3 17RP/CK CK/AB
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 6/28/2019
BID DOCUMENTS
558-18-150
1/8" = 1'-0"1
FIFTH FLOOR PLAN
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
0' 8'4' 16'
1. DIMENSIONS SHOWN ON THE FLOOR PLANS FOR NEW CONSTRUCTION ARE TO
CENTERLINE OF COLUMNS AND TO FACE OF INTERIOR PARTITIONS.
2. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR
SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE ARCHITECT
BEFORE CONTINUING WITH CONSTRUCTION.
3. ACCESSIBLE WATER CLOSETS SHALL BE MOUNTED SO THAT THERE IS 1'-6"
BETWEEN FACE OF THE CLOSEST ADJACENT SIDE WALL AND THE CENTERLINE OF THE
WATER CLOSET. THE FLUSH VALVE FOR ACCESSIBLE WATER CLOSETS SHALL BE
MOUNTED ON THE "MOST OPEN" SIDE OF THE WATER CLOSET AT 44" MAXIMUM A.F.F.
TO THE TOP.
4. FOR FURTHER DIMENSIONING, SEE SECTIONS, INTERIOR ELEVATIONS, AND
DETAILS.
5. ALIGN FINISHED FACE OF CONTINUOUS PARTITIONS THAT CHANGE PARTITION
TYPES ALONG A STRAIGHT RUN.
6. ALL PARTITIONS TO BE G4.0, UNLESS NOTED OTHERWISE.
7. ALL FURRING WALLS AROUND CHASES TO BE F4.0, UNLESS NOTED OTHERWISE.
8. ALL FURRING WALLS AROUND EXISTING COLUMNS TO BE F2.0, UNLESS NOTED
OTHERWISE.
1 3 4 5 7 10 11 12
13 14 15 16
5.1 96 8
L
S
T
N
Q
R
M
P
R.1
9' - 6 3/4" 20' - 0" 20' - 0" 20' - 0" 21' - 2" 20' - 0" 20' - 0" 10' - 6" 8' - 9"
11 3/4"
4' - 7 1/2"
V
IF
1/ 2"
8'
0"
V
IF
/2
1'
1"
VIF
14' - 4 1/2" 8' - 0"
VIF
14' - 0 3/4"
8' - 0"
7" TYP 1'
1"
PATIENT RM
B5008
CARE
STATION
B5009
PATIENT RM
B5010
PATIENT RM
B5011
PATIENT RM,
BARIATRIC
B5012
LOCKER
B5014 PATIENT RM
B5016
SOILED
UTILITY
B5018
STAFF
LOUNGE
B5015
CLEAN
SUPPLY
B5019
ALCOVE
B5020
PATIENT RM
B5021
PATIENT RM
B5022
PATIENT RM
B5024
PATIENT RM
B5025
PASSAGE
B5041
NOUR
B5026
MEDS
B5027
BATH
B5007A
CORRIDOR
B5040
BATH
B5008ABATH
B5010A
BATH
B5011A
BATH
B5016A
BATH
B5024A
BATH
B5025A
BATH
B5021A
BATH
B5022A
STAIR
B5050
STAFF TLT
B5014A
PATIENT RM,
ISOLATION
B5028
BATH
B5028A
ANTE
B5028B
PATIENT RM,
ISOLATION
B5029
BATH
B5029A
ANTE
B5029B
PATIENT RM,
BARIATRIC
B5007
CARE
STATION
B5005
EQUIP
B5004
BATH
B5012A
CARE
STATION
B5013
CARE
STATION
B5023
NURSE MGR
OFFICE
B5030
EQUIP
B5017 TEAM WORK
ROOM
B5031
OIT
B5003A
ELEC
B5017A
1'
1/
4"
10' - 0" 20' - 0" 13' - 9" 7' - 6" VIF 9' - 3 1/2"
8' - 2 1/4"
1' - 1 1/4"
6' - 4" 15' - 0 3/4" 7' - 5 1/4" 14' - 6 3/4" 9' - 3" 16' - 10"
7' - 1 1/4"
3/
4"
/2
6'
0"
3/
4"
7' - 0" TYP
9'
3" T
Y P
1'
1/
4" T
Y P
6'
7'
/2
7'
6" 5'
/2
3' - 2"
2' - 9 1/2" 4' - 3"
4' - 4 1/4" 6' - 7 1/4" 6' - 5" 6' - 5" 3' - 7 3/4" 4' - 3 3/4" 6' - 5" 11' - 4" 1' - 3"3' - 3 1/2" 4' - 9" 2' - 3" 3' - 7 1/2"
1'
1/
4" T
Y P
5'
7' - 11" 5' - 5 3/4"
2' - 6"
7'
0" T
Y P
9' - 3" TYP
1' - 5 1/4" TYP
6' - 1" 3' - 0" 3' - 7 3/4"
2'
6" 3'
0"
2'
7"
1'
/4
2'
6"
G4.1 S4.2
S4.2 G4.1
F4.0
G6.0S F4.0
G4.2
G4.2
S4.2
G6.0 F6.0
F2.0
G4.0
G4.0SG4.1
G4.1G4.1
F4.0
G6.1
G4.0
G4.1
F4.0 G4.1 G4.1
G4.1
F4.0 F4.0
G6.0S
F4.0
F2.0
F2.0
F4.0 F4.0 F2.0
F2.0F4.0
F4.0 1'
1/
2" V
IF
1'
9" V
IF
1'
9" V
IF
F4.0 F2.0F4.0
F4.0
G4.0S
G4.0S
G4.0S
F4.0
G4.0S
F2.0
7'
0"
7'
0"
F2.0
F2.0
G4.0S
G4.0S
G4.0S
4'
6"
G4.0
BIO
B5003
1 PARTITION INTENDED TO BE CENTERED ON COLUMN LINE.
2 ALIGN NEW WALL FACE W/ EXISTING.
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N A
11389
C
UL
LEN
S. KEEN
C H A R
LOTTE, NORTH
CA
RO
L
IN
A
# SHEET KEY NOTES:
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:2
:1
P M
AI102
FIFTH FLOOR DIMENSION PLAN
4 17RP/CK CK/AB
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 6/28/2019
BID DOCUMENTS
558-18-150
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
1/8" = 1'-0"1
FIFTH FLOOR DIMENSION PLAN
0' 8'4' 16'
EXP
EXP
7' - 6"8' - 6" 8' - 6" 8' - 6"
8' - 6" 8' - 0"
8' - 6"
8' - 6" 8' - 6" 8' - 6" 8' - 6"
8' - 6"
8' - 6"
8' - 6"
8' - 6" 8' - 6"
8' - 6"
8' - 6"
8' - 6" 8' - 6"
7' - 6"
8' - 0"
7' - 6"
8' - 0"
8' - 6"
8' - 6"
8' - 6"
7' - 6"
8' - 6"
8' - 0" 8' - 0"
8' - 0" 8' - 0" 8' - 0"
8' - 0" 8' - 0"
8' - 6"
8' - 6" 8' - 6"
8' - 0"
7' - 10"
8' - 0"
7' - 6"
7' - 10"
7' - 10"
7' - 6" 7' - 6" 7' - 6"
7' - 6"
8' - 0"
8' - 6"
8' - 6"
8' - 6"
8' - 6" 8' - 6"
7' - 10"
7' - 10" 7' - 10" 7' - 10" 7' - 10" 7' - 10" 7' - 10"7' - 10" 7' - 10"
8' - 0"
8' - 0" 8' - 0" 8' - 0" 8' - 0"8' - 0" 8' - 0" 8' - 0"
7' - 10"
7' - 6"
8' - 0"
8' - 0"
AI501
AI501
AI501
AI501
AI501
AI501
AI501
AI501
AI501
AI501
AI5013' - 0" 3' - 0" 3' - 0"
3' - 0" 3' - 0"
3' - 0" 3' - 0" 3' - 0"
3'
222 2
PATIENT RM
B5008
CARE STATION
B5009
PATIENT RM
B5010
PATIENT RM
B5011
PATIENT RM,
BARIATRIC
B5012
LOCKER
B5014
PATIENT RM
B5016
SOILED UTILITY
B5018
STAFF LOUNGE
B5015 CLEAN SUPPLY
B5019
ALCOVE
B5020 NOUR
B5026
MEDS
B5027
BATH
B5007A
CORRIDOR
B5040
BATH
B5008A
BATH
B5010A
BATH
B5011A
BATH
B5016A
STAIR
B5050
STAFF TLT
B5014A
PATIENT RM,
ISOLATION
B5028
BATH
B5028A
ANTE
B5028B
PATIENT RM,
ISOLATION
B5029
BATH
B5029A
ANTE
B5029B
PATIENT RM,
BARIATRIC
B5007
CARE STATION
B5005
EQUIP
B5004
BATH
B5012A
CARE STATION
B5013
NURSE MGR
OFFICE
B5030
EQUIP
B5017
TEAM WORK
ROOM
B5031
OIT
B5003A
ELEC
B5017A
BIO
B5003
1. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE REFLECTED CEILING
PLANS WITH THE ELECTRICAL LIGHTING PLANS, WITH THE MECHANICAL SUPPLY, RETURN AND
EXHAUST PLANS, AND WITH THE FIRE PROTECTION PLANS, AND CONTRACTOR SHALL REPORT
TO THE COR ANY INCONSISTENCY THAT HE MAY DISCOVER PRIOR TO PROCEEDING.
2. VERIFY THAT ACCESS PANELS OF APPROPRIATE SIZE AND TYPE ARE INSTALLED IN GYPSUM
BOARD CEILINGS OR SOFFITS, IN CEMENT PLASTER CEILINGS OR SOFFITS, AND IN OTHER
NON-ACCESSIBLE TYPE CEILINGS OR SOFFITS WHERE ACCESS, SERVICE OR ADJUSTMENT TO
MECHANICAL, PLUMBING OR ELECTRICAL ITEMS MAY BE REQUIRED. ACCESS PANELS SHALL
BE THE FIRE RATED TYPE EQUAL TO THE RATING OF THE CEILING OR SOFFIT IN WHICH THEY
OCCUR.
3. COORDINATE WITH COR ANY INSTANCE WHERE CEILING TILES ARE LESS THAN 4" IN WIDTH.
4. WHERE FIELD CONDITIONS CAUSE VARIATIONS IN THE REFLECTED CEILING PLAN, ANY
ADJUSTMENTS TO ITEM LOCATIONS SHALL BE COORDINATED WITH COR.
9. FRAME ELECTRICAL FIXTURES AND MECHANICAL DIFFUSERS. COORDINATE WITH
MECHANICAL & ELECTRICAL SUBCONTRACTORS.
10. CENTER DEVICES INCLUDING DOWNLIGHTS, SPRINKLER HEADS, AND HVAC GRILLES
SMALLER THAN 2 BY 2 FEET, IN CEILING TILES, U.N.O.
11. CENTER EXIT SIGNS OVER DOORS, U.N.O.
12. CEILING HEIGHTS TO BE 9'-0" A.F.F., U.N.O.
13. SOFFITS HEIGHTS TO BE 8'-0" A.F.F., U.N.O.
1 ALIGN SOFFIT W/ WALL.
2 CENTER SOFFIT ON COLUMN LINE.
3 CORRIDOR SOFFITS ARE INTENDED TO COORDINATE W/ LINEAR
LIGHT FIXTURE DIMENSIONS. CONTRACTOR SHALL OBTAIN
ACTUAL DIMENSIONS OF LIGHT FIXTURES AND FIELD VERIFY
THE PLACEMENT OF SOFFITS. COORDINATE ANY CHANGES
WITH COR.
4 ACCESS PANEL, 12"X12", TYPICAL AT BATHROOM CEILINGS.
COORDINATE LOCATION W/ COR FOR PROPER ACCESS TO HVAC
DAMPERS.
2'x4' Acoustical Tile
REFLECTED CEILING PLAN
LEGEND
Access Panel
Lay-in Light
EXP
Indirect Lay-in Light
2'x2' Acoustical Tile
Gypsum Board Ceiling
Recessed Downlight
Wall Mounted Light
Exit Sign
Strip Light
Supply
Return
Exhaust Air Grill
Elevation Marker
Under Cabinet Light
Recessed Heat Lamp
Exposed to Structure
Cubicle Curtain Track
Lift Track
Ceiling Mounted Equipment
8'-0" Spot Elevation Tag
9'-0"
Sprinkler Head
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N A
11389
C
UL
LEN
S . KEEN
C H A R
LOTTE , NORTH
CA
RO
L
IN
A
# SHEET KEY NOTES:
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS PROJECT
SHEET NOTES:
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:0
P
M
AI121
FIFTH FLOOR REFLECTED CEILING
PLAN
5 17RP/CK CK/AB
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 6/28/2019
BID DOCUMENTS
558-18-150
1/8" = 1'-0"1
FIFTH FLOOR REFLECTED CEILING PLAN
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
0' 8'4' 16'
N Q RM P R.1
M
REMOVE GLAZED TILE
REMOVE GLAZED TILE
REMOVE GLAZED TILE
REMOVE CEILING ASSEMBLY
EXISTING DAMPPROOFING TO BE ADDRESSED UNDER ASBESTOS ABATEMENT
EXISTING CMU TO REMAIN
EXISTING CONC TO REMAIN
REMOVE INTEGRAL BLINDS, EXISTING
WINDOW FRAME AND GLAZING TO
REMAIN INTACT
TEMPORARILY REMOVE BRACKET
HOLDING INTERIOR AND EXTERIOR
GLAZING UNITS TOGETHER TO
FACILITATE REMOVAL OF BLINDS
TEMPORARILY REMOVE BRACKET
HOLDING INTERIOR AND EXTERIOR
GLAZING UNITS TOGETHER TO
FACILITATE REMOVAL OF BLINDS
REMOVE WINDOW LATCH, PREP FOR
NEW TAMPER-RESISTANT LATCH
REMOVE WINDOW LATCH, PREP FOR
NEW TAMPER-RESISTANT LATCH
M
2 1/2" METAL STUDS
5/8" GYP BD
6" METAL STUDS
5/8" GYP BD
1" RIGID INSULATION TO REPLACE EXISTING
SOLID SURFACE SILL, SLOPE TOP 3:12
WOOD BLOCKING
1"
CEILING SYSTEM
6"
MANUAL ROLLER SHADE
INSTALL TAMPER-RESISTANT W INDOW LATCH
INSTALL TAMPER-RESISTANT W INDOW LATCH
SEAL ALL EDGES OF WINDOW OPENING IN SHUT
POSITION, USE SEALANT COLOR MATCHED TO
WINDOW FRAME (BLACK)
NEW DAMPPROOFING SYSTEM
M
2 1/2" METAL STUDS
5/8" GYP BD
SOLID SURFACE SILL, SLOPE TOP 3:12
WOOD BLOCKING
1"
2 1/2" METAL STUDS
5/8" GYP BD
CEILING SYSTEM
6"
MANUAL ROLLER SHADE
INSTALL TAMPER-RESISTANT W INDOW LATCH
INSTALL TAMPER-RESISTANT W INDOW LATCH
SEAL ALL EDGES OF WINDOW OPENING IN SHUT
POSITION, USE SEALANT COLOR MATCHED TO
WINDOW FRAME (BLACK)
NEW DAMPPROOFING SYSTEM
M
4" METAL STUDS
5/8" GYP BD
OUTLINE OF W INDOW SILL AND FURRING BEYOND
OPEN TO PLENUM TO ALLOW VENTING
RETURN FURRING TO
EXTERIOR WALL
CEILING SUPPORT SYSTEM
6"
10" VIF
4" MIN
APPLY BLACKOUT FILM ON GLASS
INSTALL TAMPER-RESISTANT W INDOW LATCH
INSTALL TAMPER-RESISTANT W INDOW LATCH
SEAL ALL EDGES OF WINDOW OPENING IN SHUT
POSITION, USE SEALANT COLOR MATCHED TO
WINDOW FRAME (BLACK)
1" RIGID INSULATION TO REPLACE EXISTING
NEW DAMPPROOFING SYSTEM
1" 1"
1' - 6"
4 3/4"
3/
4"
DRILLED EPOXY ANCHOR
SET IN BRICK VENEER
DRILLED EPOXY ANCHOR
SET IN PRECAST VENEER
EXISTING MASONRY WALL
DUCT SUPPORT BRACKET @ 48" OC,
2"X2"X1/4" STEEL ANGLE W/ FULLY
WELDED CONNECTIONS,
GALVANIZED AND PAINTED
EXISTING ROOF
REF TO MECH FOR DUCT INFORMATION
ATTACH DUCT TO BRACKET W/
GALVANIZED STEEL STRAP
EXISTING CONC STRUCTURE
EXISTING LIGHT WEIGHT INSULATING CONC
EXISTING ROOF SYSTEM
PATCH ROOF SYSTEM AND INSULATING CONC AS REQUIRED
PREFABRICATED PIPE BOOT AND COMPRESSION RING
SEALANT
STEEL PIPE W/ FULLY-WELDED CAP, WELDED TO BASE
PLATE, GALVANIZED, PAINTED
STEEL EYE, GALVANIZED
FILL PIPE W/ PREFORMED URETHANE INSULATION
STEEL BASE PLATE, GALVANIZED
STEEL BOLTS, GALVANIZED
STEEL DISTRIBUTION PLATE, PRIMED
1'
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N A
11389
C
UL
LEN
S . KEEN
C H A R
LOTTE , NORTH
CA
RO
L
IN
A
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS PROJECT
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:0
P
M
AI301
ARCHITECTURAL SECTIONS
6 17RP/CK CK/AB
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 6/28/2019
BID DOCUMENTS
558-18-150
1/4" = 1'-0"1
TYPICAL BUILDING SECTION - 5TH FLOOR
3/4" = 1'-0"2
EXTERIOR WALL SECTION - DEMOLITION
3/4" = 1'-0"4
EXTERIOR WALL SECTION - AT HVAC EQUIP
3/4" = 1'-0"3
EXTERIOR WALL SECTION - TYPICAL
3/4" = 1'-0"5
EXTERIOR WALL SECTION - AT FURRING
0' 1'-0"6" 2'-0" 0' 1'-0"6" 2'-0"0' 1'-0"6" 2'-0" 0' 1'-0"6" 2'-0"0' 4'2' 8'
3/4" = 1'-0"6
EXTERIOR DUCT SUPPORT SECTION
0' 1'-0"6" 2'-0"
1 1/2" = 1'-0"7
TYPICAL GUY WIRE ANCHOR DETAIL
0' 6"3" 12"
0"
SLOPE UP 1/8":12"
+0.625"
+0.75"
1/8" HIGH THRESHOLD
+0.625"
+0.625"
SLOPE DN 1/4":12"
-0.5" +
.2
5'
4' - 0" VIF
2'
V
IF
INSTALL TOPPING SLAB AS REQUIRED TO ACHIEVE
SLOPES INDICATED, USE SAND/TOPPING MIX LISTED
FOR RANGE OF TOPPING THICKNESS REQUIRED,
REFER TO SPECIFICATIONS SECTION 033053 FOR
INSTALLATION REQUIREMENTS.
PATIENT RM
B5011
BATH
B5011A
REMOVE MAXIMUM 1/2" OF
EXISTING SLAB IN AREA
NECESSARY TO ACHIEVE
SLOPE TO DRAIN
0"
SLOPE UP 1/8":12"
+0.625"
+0.75"
1/8" HIGH THRESHOLD
+0.625"
+0.625"
-0.5"
SLOPE DN 1/4":12"
5'
1'
V
IF
5' - 0" VIF
PATIENT RM,
BARIATRIC
B5012
BATH
B5012A
INSTALL TOPPING SLAB AS REQUIRED TO ACHIEVE
SLOPES INDICATED, USE SAND/TOPPING MIX LISTED
FOR RANGE OF TOPPING THICKNESS REQUIRED,
REFER TO SPECIFICATIONS SECTION 033053 FOR
INSTALLATION REQUIREMENTS.
REMOVE MAXIMUM 1/2" OF
EXISTING SLAB IN AREA
NECESSARY TO ACHIEVE
SLOPE TO DRAIN
5'
-0.5"
3'
V
IF
1' - 10" VIF
SLOPE UP 1/8":12"
1/8" HIGH THRESHOLD
SLOPE DN 1/4":12"
+0.625"
+0.75"
+0.625"
+0.625"
0"
PATIENT RM,
ISOLATION
B5029
ANTE
B5029B
BATH
B5029A
INSTALL TOPPING SLAB AS REQUIRED TO ACHIEVE
SLOPES INDICATED, USE SAND/TOPPING MIX LISTED
FOR RANGE OF TOPPING THICKNESS REQUIRED,
REFER TO SPECIFICATIONS SECTION 033053 FOR
INSTALLATION REQUIREMENTS.
REMOVE MAXIMUM 1/2" OF
EXISTING SLAB IN AREA
NECESSARY TO ACHIEVE
SLOPE TO DRAIN
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N A
11389
C
UL
LEN
S . KEEN
C H A R
LOTTE , NORTH
CA
RO
L
IN
A
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS PROJECT
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:0
P
M
AI401
ENLARGED FLOOR SLOPE PLANS
7 17RP/CK CK/AB
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 6/28/2019
BID DOCUMENTS
558-18-150
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
1/2" = 1'-0"1
ENLARGED FLOOR SLOPE PLAN - TYPICAL PATIENT ROOM
1/2" = 1'-0"2
ENLARGED FLOOR SLOPE PLAN - BARIATRIC ROOM
1/2" = 1'-0"3
ENLARGED FLOOR SLOPE PLAN - ISOLATION ROOM
0' 2'1' 4' 0' 2'1' 4'
0' 2'1' 4'
A5212
A1200A
U0001
3' - 9"
FILLER PANEL
AI541
AI541
3'
COUNTERTOP, SCRIBED TO WALL, SSM-1
BASE CABINET PLAM-1
SCHEDULED BASE
5'
3'
A5212
A1200A
A11102' - 1"
2' - 0"
8' - 0" NOMINAL
A1110
6'
N O
M
IN
A L
SCONCE
VITALS MONITOR MOUNT
TELEMETRY MONITOR MOUNT
BED BUMPERS
8'
EQUIPMENT RAIL, EACH SIDE, W / BOTTLE
SLIDE STANDARD
MEDICAL GASES
ELEC/DATA RECEPTACLES
LAMINATE FOR HEADWALL - WILSONART
SHAKER CHERRY 7935K-07
A1110
M1802
U0001
A1200A
A5212
3'
2' - 1"
2' - 0"
AI541
AI541
2' - 6"
3'
3'
PLAM-1 CABINET
SCHEDULED BASE
A5109A
A5080
A5205
2'
0"
A5109D
A5109D
2' - 1"
1' - 9"
TILE FULL HEIGHT OF WALL
SCHLUTER - DILEX-AHK TRANSITION BETWEEN
WALL TILE TO FLOOR TILE - TYPICAL ALL BATHROOMS
A1200A
2'
0"
A5205
A5080
A5075
A1066
1' - 3"
2'
0"
A5109
A5200
A5090
A1200A
3' - 3"
1' - 0"A5075
SCHLUTER - DILEX-AHK TRANSITION BETWEEN
WALL TILE TO FLOOR TILE - TYPICAL ALL BATHROOMS
TILE FULL HEIGHT OF WALL
A1200A
A5109
A5200
A5109A
A5175
A5109D
6"
2' - 3"
1' - 4"
1' - 6"
TILE FULL HEIGHT OF WALL
SCHLUTER - DILEX-AHK TRANSITION BETWEEN
WALL TILE TO FLOOR TILE - TYPICAL ALL BATHROOMS
2' - 0" 2' - 6"
AI541
AI541
A5075
A5080
A5106S A5106G
3'
SSM-1 COUNTERTOP AND
BACKSPLASH
PLAM-1 FINISHED END PANEL
PLAM-1 BASE CABINETS
A1200B
A5212
3' - 9"
3'
AI541
AI541
SSM-1 COUNTERTOP
AND BACKSPLASH
PLAM BASE CABINET
SCHEDULE BASE
5'
A1110
A1200B
A1110
U0001
A1200A
SCONCE
VITALS MONITOR MOUNT
TELEMETRY MONITOR MOUNT
BED BUMPERS
EQUIPMENT RAIL, EACH SIDE, W / BOTTLE
SLIDE STANDARD
MEDICAL GASES
ELEC/DATA RECEPTACLES
M1802
LAMINATE FOR HEADWALL - WILSONART
SHAKER CHERRY 7935K-07
A1110
M1802
U0001 A1200B
A5212
3'
2' - 0"
2' - 1"
6' - 3" (4 EQ)
3' - 5" 2' - 9" 3' - 0"
AI541
6" 2'
1'
2'
0" K4665
R7000
AI541
AI541
A5075
A5080
PLAM-1 WALL CABINETS AND SLOPED TOP
SSM-3 COUNTERTOP AND BACK WALL PANEL
PLAM-1 FINISHED END PANEL
PLAM-1 BASE CABINETS
SCHEDULED BASE
A1200B
A5090
A5200
A5109
1' - 0" 3' - 6"
TILE FULL HEIGHT OF WALL
SCHLUTER - DILEX-AHK TRANSITION
BETW EEN WALL TILE TO FLOOR TILE -
TYPICAL ALL BATHROOMS
A5205
A1200B
A5109C
A5109D
A5175
6"
4' - 2"
10"
1' - 4"
TILE FULL HEIGHT OF WALL
SCHLUTER - DILEX-AHK TRANSITION BETWEEN
WALL TILE TO FLOOR TILE - TYPICAL ALL BATHROOMS
A5080
A5075
A1066
A5080
A1066
A5075
A5109
A5200
A1200B
SCONCE - REF TO ELEC
1' - 6"
6"
1' - 9"
SCHLUTER-SCHIENE SIDE CAP
SCHLUTER - DILEX-AHK TRANSITION BETWEEN
WALL TILE TO FLOOR TILE - TYPICAL ALL BATHROOMS
TILE FULL HEIGHT OF WALL
A5080
A5075 M3150A
M3150
R6400
AI541
2' - 6" 1' - 3" 2' - 6"
AI541
AI541
2'
0"
2'
2'
0"
1'
2'
6"
R6200
F2017
K4665
6' - 3" (6 EQ)
2' - 6" 2' - 3"
AI541
AI541
A5075 A5080
AI541
AI541
PLAM-1 WALL CABINETS AND
TOP SLOPE
SSM-3 COUNTERTOP AND BACK WALL PANEL
PLAM-1 BASE CABINET
R4750
R6200L
R6200
AI541
3'
2'
0"
FINISHED END PANELS IN CORNER
SSM-3 COUNTERTOP AND BACK WALL PANEL
1'
AI541
AI541
2'
3'
1'
1' - 0"
5' - 0"
SSM-2 TRANSACTION TOP
AND FRONT PANEL
SSM-1 TOP CAP
PLAM-1 PANEL
1/4" RECESS BRUSHED ALUMINUM
REVEALS
PROVIDE PLAM-2 FINISHED END PANEL FOR
TRANSACTION TOP
WORK STATIONS PROVIDED BY OTHERS
AI541
AI541
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N A
11389
C
UL
LEN
S . KEEN
C H A R
LOTTE , NORTH
CA
RO
L
IN
A
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS PROJECT
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:0
P
M
AI431
INTERIOR ELEVATIONS
8 17RP/CK CK/AB
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 6/28/2019
BID DOCUMENTS
558-18-150
1/4" = 1'-0"1
TYPICAL PATIENT ROOM - WEST
1/4" = 1'-0"2
TYPICAL PATIENT ROOM - NORTH
1/4" = 1'-0"3
TYPICAL PATIENT ROOM - EAST
1/4" = 1'-0"4
TYPICAL PATIENT ROOM - SOUTH
1/4" = 1'-0"5
PERSONAL PROTECTIVE EQUIPMENT CABINET
1/4" = 1'-0"6
TYPICAL PATIENT BATHROOM - WEST
1/4" = 1'-0"7
TYPICAL PATIENT BATHROOM - NORTH
1/4" = 1'-0"8
TYPICAL PATIENT BATHROOM - EAST
1/4" = 1'-0"9
TYPICAL PATIENT BATHROOM - SOUTH
1/4" = 1'-0"10
SOILED UTILITY
1/4" = 1'-0"11
BARIATRIC PATIENT ROOM - WEST
1/4" = 1'-0"12
BARIATRIC PATIENT ROOM - NORTH
1/4" = 1'-0"13
BARIATRIC PATIENT ROOM - EAST
1/4" = 1'-0"14
BARIATRIC PATIENT ROOM - SOUTH
1/4" = 1'-0"15
STAFF LOUNGE
1/4" = 1'-0"16
BARIATRIC BATHROOM - WEST
1/4" = 1'-0"17
BARIATRIC BATHROOM - NORTH
1/4" = 1'-0"18
BARIATRIC BATHROOM - EAST
1/4" = 1'-0"19
BARIATRIC BATHROOM - SOUTH
1/4" = 1'-0"20
MEDICATIONS
1/4" = 1'-0"21
NOURISHMENT - EAST
1/4" = 1'-0"22
NOURISHMENT - SOUTH
1/4" = 1'-0"23
CARE STATION - NORTH
1/4" = 1'-0"24
CARE STATION - EAST
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
NURSE STATION
A1200C
A5212
3'
3' - 9"
AI541
AI541
SSM-1 COUNTERTOP
AND BACKSPLASH
PLAM-1 BASE CABINET5'
A1110
M1802
U0001
A1200C
A5212
3'
2' - 1"
2' - 0"
U0001
M1802
A1110
A1200C
6'
8' - 0" NOMINAL
SCONCE
VITALS MONITOR MOUNT
TELEMETRY MONITOR MOUNT
BED BUMPERS
EQUIPMENT RAIL, EACH SIDE, W / BOTTLE
SLIDE STANDARD
MEDICAL GASES
ELEC/DATA RECEPTACLES
LAMINATE FOR HEADWALL - WILSONART
SHAKER CHERRY 7935K-07
A1200C
A5212
3'
" 2' - 0"
2' - 1"
6" 2'
4'
2' - 6"
A5080
A5075
AI541
A5109B
A5109A
A5109
A5200
A5175
A5109D 8"
2' - 0"
6"
6"
1' - 6"
SCHLUTER - DILEX-AHK TRANSITION BETWEEN
WALL TILE TO FLOOR TILE - TYPICAL ALL BATHROOMS
TILE FULL HEIGHT OF WALL
A5109
A5090
A5200
1' - 0"
A5109D
TILE FULL HEIGHT OF WALL
SCHLUTER - DILEX-AHK TRANSITION BETWEEN
WALL TILE TO FLOOR TILE - TYPICAL ALL BATHROOMS
A5080
A5075
A5205
A5109A
A5109B
A1066
A5080
A5075
2'
0"
2' - 6"
6"
2' - 9"
1' - 3"
F
U
LL
T
IL
E S
TILE FULL HEIGHT OF WALL
SCHLUTER - DILEX-AHK TRANSITION BETWEEN
WALL TILE TO FLOOR TILE - TYPICAL ALL BATHROOMS
SCHLUTER-SCHIENE SIDE CAP
3'
GRAB BAR
1'
0"
TOILET PAPER
DISPENSER
(VERIFY HGT W/ COR
AND VA FURNISHED
EQUIP INFO)
3'
SOAP DISPENSER
WALL MOUNTED
3'
MIRROR
2'
SANITARY NAPKIN
DISPOSAL
3'
WALL MOUNT
PAPER TOWEL DISPENSER
4'
TOWEL BAR
4'
ROBE HOOK
2'
0"
LAVATORY
WALL MOUNTED
1'
TOILET
1'
0"
TOILET PAPER
DISPENSER
(VERIFY HGT W/ COR
AND VA FURNISHED
EQUIP INFO)
SHOWER
HEAD
FIRE
EXTINGUISHER
T O
T O
P O
F T
A N
K
3'
CABINET PER SPECS
1'
URINAL
3'
/2
1'
3'
3'
/2
2'
SERVICE SINK
WALL MOUNTED
1'
TYPICAL MOUNTING
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N A
11389
C
UL
LEN
S . KEEN
C H A R
LOTTE , NORTH
CA
RO
L
IN
A
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS PROJECT
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:1
P
M
AI432
INTERIOR ELEVATIONS
9 17RP/CK CK/AB
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 6/28/2019
BID DOCUMENTS
558-18-150
1/4" = 1'-0"1
ISOLATION PATIENT ROOM - WEST
1/4" = 1'-0"2
ISOLATION PATIENT ROOM - NORTH
1/4" = 1'-0"3
ISOLATION PATIENT ROOM - EAST
1/4" = 1'-0"4
ISOLATION PATIENT ROOM - SOUTH
1/4" = 1'-0"5
ISOLATION ANTEROOM
1/4" = 1'-0"6
ISOLATION BATHROOM - WEST
1/4" = 1'-0"7
ISOLATION BATHROOM - NORTH
1/4" = 1'-0"8
ISOLATION BATHROOM - EAST
1/4" = 1'-0"9
ISOLATION BATHROOM - SOUTH
SPECIALTY EQUIPMENT SCHEDULE (BASIS OF DESIGN)
Type Mark Description
Furnish -Install Manufacturer Model
A1012
A1030 LOCKER, 3-TIER CFCI REFER TO SPECIFICATIONS REFER TO SPECIFICATIONS
A1066 MIRROR, FRAMED, 24"x36" CFCI BOBRICK, OR EQUAL B-290
A1110 PATIENT BED SERVICE WALL CFCI REFER TO SPECIFICATIONS REFER TO SPECIFICATIONS
A1200A LIFT, PATIENT, CEILING-MOUNT, 600 LB CAPACITY CFCI BARRIER FREE LIFTS UNILIFT
A1200B LIFT, PATIENT, CEILING-MOUNT, 1,000 LB CAPACITY CFCI BARRIER FREE LIFTS UNILIFT
A1200C LIFT, PATIENT, CEILING-MOUNT, 600 LB CAPACITY CFCI BARRIER FREE LIFTS UNILIFT
A5075 DISPENSER, SOAP, WALL-MOUNT OFCI N/A N/A
A5080 DISPENSER, PAPER TOWEL, WALL-MOUNT OFCI BOBRICK, OR EQUAL B-262
A5090 DISPOSAL, SANITARY NAPKIN CFCI BOBRICK, OR EQUAL B-254
A5106G GLOVE DISPENSER, OFOI OFCI BOBRICK, OR EQUAL B-262
A5106S DISPOSAL, SHARPS OFCI N/A N/A
A5109 GRAB BAR COMBINATION (42", 36", 18") CFCI BOBRICK, OR EQUAL B-5806
A5109A GRAB BAR (42") CFCI BOBRICK, OR EQUAL B-5806
A5109B GRAB BAR (36") CFCI BOBRICK, OR EQUAL B-5806
A5109C GRAB BAR (60") CFCI BOBRICK, OR EQUAL B-5806
A5109D GRAB BAR (18") CFCI BOBRICK, OR EQUAL B-5806
A5175 SOAP DISH CFCI BOBRICK, OR EQUAL B-4390
A5180 CUBICLE CURTAIN TRACK CFCI REFER TO SPECIFICATIONS
AND INTERIOR FINISH
SCHEDULE
REFER TO SPECIFICATIONS
AND INTERIOR FINISH
SCHEDULE
A5200 DISPENSER, TOILET PAPER OFCI N/A N/A
A5205 TOWEL BAR CFCI BOBRICK, OR EQUAL B-530
A5212 BRACKET, TELEVISION, WALL-MOUNT OFCI N/A N/A
E0954 CART, RESUSCITATION OFOI N/A N/A
E0974A SHELVING, MOBILE, BASE ONLY, 42"X18" OFOI N/A N/A
E0974B SHELVING, MOBILE, BASE ONLY, 36"X18" OFOI N/A N/A
E0974C SHELVING, MOBILE, BASE ONLY, 48"X18" OFOI N/A N/A
E0975A SHELVING, MOBILE, 48"X18" OFOI N/A N/A
F0530 CART, WASTE OFOI N/A N/A
F2017 WASTE CAN OFOI N/A N/A
F2017L WASTE CAN, LARGE OFOI N/A N/A
F2020 WASTE CAN, LARGE ROUND OFOI N/A N/A
F2100 WASTE CAN, PHARMACEUTICAL OFOI N/A N/A
K660 MICROWAVE, WIPE WARMER OFOI N/A N/A
K4665 MICROWAVE OFOI N/A N/A
M1801 COMPUTER, DESKTOP W/ DUAL MONITORS OFOI N/A N/A
M1802 COMPUTER, WALL BRACKET MOUNTED OFOI N/A N/A
M1810 COPIER, FLOOR, MULTI-FUNCTION OFOI N/A N/A
M2050A SHELVING, MOBILE, 60"X24" OFOI N/A N/A
M2050B SHELVING, MOBILE, 72"X24" OFOI N/A N/A
M3070 HAMPER, LINEN OFOI N/A N/A
M3110 WARMER, BLANKET OFOI N/A N/A
M3150 DISPENSER, MEDICATION, MAIN OFOI TBD TBD
M3150A DISPENSER, MEDICATION, DOUBLE TOWER OFOI N/A N/A
M4116 MONITOR, VITALS, PORTABLE OFOI N/A N/A
M4255 STAND, IV OFOI N/A N/A
M4880A BRACKET, TELEMETRY MONITOR, WALL-MOUNT OFCI N/A N/A
M7010 BED, PATIENT OFOI N/A N/A
M7040 TABLE, OVERBED OFOI N/A N/A
M8080 LIFT, PATIENT, PORTABLE OFOI N/A N/A
R4750 ICE MAKER, COUNTERTOP OFCI TBD TBD
R6200 REFRIGERATOR, UNDERCOUNTER OFOI N/A N/A
R6200L REFRIGERATOR, UNDERCOUNTER, LOCKABLE OFOI N/A N/A
R6400 REFRIGERATOR, UNDERCOUNTER, MEDICATION OFOI N/A N/A
R7000 REFRIGERATOR, DOMESTIC OFOI N/A N/A
U0001 MANUFACTURED CASEWORK. ITEM SHALL INCLUDE ADA
SINK/COUNTER, ADA SINK ENCLOSURE, FAUCET ASSEMBLY,
UPPER GLOVE CABINET, EQUIPMENT RAIL, AND ALL
NECESSARY SUPPORTS AND CLOSURE PIECES.
SINK/COUNTER SHALL BE INTEGRAL SOLID SURFACE
MATERIAL SSM-1 AS SPECIFIED ON INTERIOR FINISH
DRAWINGS. OTHER EXPOSED SURFACES SHALL BE FINISHED
W/ DURAWRAP 'LIGHT BROWN WALNUT 76', OR EQUAL.
PROVIDE MOCK-UP OF MANUFACTURERED CASEWORK.
CFCI HERMAN MILLER COMPASS SYSTEM
U0020 CART, OXYGEN CYLINDER OFOI N/A N/A
U1001 SUPPLY BINS, HANGING, SMALL OFOI N/A N/A
U1002 SUPPLY BINS, HANGING, LARGE OFOI N/A N/A
UD100 INTERACTIVE DISPLAY OFOI SMART TECHNOLOGIES TBD
UH200 HANGER, BIN SYSTEM, WALL-MOUNT OFOI N/A N/A
UM001 BRACKET, PATIENT TRACKING MONITOR, WALL-MOUNT OFCI N/A N/A
UM002 BRACKET, BED MANAGEMENT SYSTEM MONITOR,
WALL-MOUNT
OFCI N/A N/A
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8'
0' 4'2' 8' 0' 4'2' 8'
NOTE:
SEE SPECIFICATION SECTIONS 010180 AND 010190
FOR REQUIREMENTS ABOUT SPECIALTY EQUIPMENT
6"
C E
IL
IN
G P
LA
N
V A
R
IE
S
S E
E R
E F
LE
C
T E
D
CEILING PLAN
VARIES - SEE REFLECTED
METAL STUDS @ 16" O.C.
BRACED TO STRUCTURE
ABOVE
5/8" GYP BD
CEILING AS SCHEDULED
CONTINUOUS CORNER
BEAD
METAL STUD BRACE
@ 4'-0" O.C.
6"
C E
IL
IN
G P
LA
N
V A
R
IE
S
S E
E R
E F
LE
C
T E
D
METAL STUDS @ 16" O.C.
BRACED TO STRUCTURE
ABOVE
5/8" GYP BD
CEILING AS SCHEDULED
CONTINUOUS CORNER
BEAD
CEILING PLAN
VARIES - SEE REFLECTED
METAL STUDS @ 16" O.C.
BRACED TO STRUCTURE
ABOVE
5/8" GYP BD
CEILING AS SCHEDULED
6" C
E
IL
IN
G
P
LA
N
V A
R
IE
S
S E
E R
E F
LE
C
T E
D
CONTINUOUS CORNER
BEAD
SEISMIC EXPANSION JOINT. COORDINATE
BLOCK-OUT WITH MFR. AND FINISH. TOP OF
JT. TO BE FLUSH WITH FLOOR FINISH
EXISTING WIDTH
ADHESIVE PER
MANUFACTURER'S
SPECIFICATIONS
RESILIENT FLOORING
SEALED CONCRETE
REDUCER STRIP
SCHLUTER - DECO TRANSISTION
LUXURY VINYL TILE
SHEET VINYL
ADHESIVE
DOOR
TILE
RESILIENT FLOORING
MARBLE THRESHOLD
TO MATCH TILE
SETTING BED
ADHESIVE PER MANUFACTURERS
SPECIFICATIONS
ADHESIVE PER
MANUFACTURER'S
SPECIFICATIONS
RESILIENT FLOORING
FLOOR TILE
REDUCER STRIP
BY JOHNSONITE
FLOOR TO BE FEATHERED
AND SLOPED TO MEET
CARPET AT SAME HEIGHT
5/8" GYP BD
4" METAL STUDS
FINISHED FLOOR
SOLID SURFACE CAP W/ EASED
EDGES, 1/2" THICK
BASE AS SCHEDULED
SOLID SURFACE TRIM, W RAP
AROUND END OF WALL
3'
/4
4"
1"
STAINLESS STEEL TOP CAP
PREFABRICATED
COVE FORM
SHEET FLOORING
AS SCHEDULED
6" U
N O
ALL SEAMS, COVES, AND
CORNERS SHALL BE SMOOTH
TO ALLOW EASE OF CLEANING
SLOPE FLOOR MINIMUM 1/4" PER FOOT
TO SHOWER DRAIN
WATERPROOFING MEMBRANE - INSTALL
PER MANUFACTURER'S INSTRUCTIONS
TILE
SHOWER DRAIN - SEE PLUMBING
BACKER BOARD
CEILING AS SCHEDULED
ROD SPACING PER MANUFACTURER REQUIREMENTS
NOTE: SEE SPECIFICATION SECTION 117300 FOR REQUIREMENTS FOR
CEILING MOUNTED PATIENT LIFT SYSTEMS. SUPPORTS AND
ANCHORAGE FOR LIFT SYSTEMS ARE THE RESPONSIBILITY OF THE
CONTRACTOR AND MANUFACTURER AND MUST BE DESIGNED BY A
STRUCTURAL ENGINEER ENGAGED BY THE MANUFACTURER. THE
STRUCTRUAL SUPPORT DESIGN MUST BE SUBMITTED AS PART OF THE
SHOP DRAWINGS.
EXISTING CONC STRUCTURE
THREADED ROD PER MANUFACTURER REQUIREMENTS
H-TRACK SUPPORT BY MANUFACTURER
TRAVEL TRACK SUPPORT BY MANUFACTURER
ANCHOR RODS TO CONC STRUCTURE
CEILING AS SCHEDULED
ROD SPACING PER MANUFACTURER REQUIREMENTS
NOTE: SEE SPECIFICATION SECTION 117300 FOR REQUIREMENTS FOR
CEILING MOUNTED PATIENT LIFT SYSTEMS. SUPPORTS AND
ANCHORAGE FOR LIFT SYSTEMS ARE THE RESPONSIBILITY OF THE
CONTRACTOR AND MANUFACTURER AND MUST BE DESIGNED BY A
STRUCTURAL ENGINEER ENGAGED BY THE MANUFACTURER. THE
STRUCTRUAL SUPPORT DESIGN MUST BE SUBMITTED AS PART OF THE
SHOP DRAWINGS.
EXISTING CONC STRUCTURE
THREADED ROD PER MANUFACTURER REQUIREMENTS
SPACE BETWEEN TRACK AND CEILING BASED ON
MANUFACTURER TRACK DEPTH
TRAVEL TRACK SUPPORT BY MANUFACTURER
ANCHOR RODS TO CONC STRUCTURE
CEILING GRID
ACOUSTICAL CEILING TILE
ACCEPTABLE REGION OF ACOUSTICAL TILE FOR
PENETRATION OF THREADED ROD, TYPICAL
1/2"
1/ 2"
1/ 2"
1/2"
THREADED ROD SUPPORT
NOTE: THREADED RODS SHALL
PENETRATE NEAR EDGES OF TILES
TO ALLOW FOR SIMPLE NOTCHING
OF CEILING TILES AROUND RODS.
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N A
11389
C
UL
LEN
S . KEEN
C H A R
LOTTE , NORTH
CA
RO
L
IN
A
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS PROJECT
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:1
P
M
AI501
INTERIOR DETAILS
10 17RP/CK CK/AB
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 6/28/2019
BID DOCUMENTS
558-18-150
1 1/2" = 1'-0"1 CEILING - Soffit Detail - Extended
1 1/2" = 1'-0"2 CEILING - Soffit Detail - Bulkhead
1 1/2" = 1'-0"3 CEILING - Soffit Detail - at Wall
3" = 1'-0"4 FLOOR - Expansion Joint - 2nd Floor
1" = 1'-0"5 FLOOR - Transition Detail - Concrete to Reslient Floor
1" = 1'-0"6 FLOOR - Transition Detail - LVT to SV
1" = 1'-0"7 FLOOR - Transition Detail - Resilient Floor to Tile at Door
1" = 1'-0"8 FLOOR - Transition Detail - Tile to Resilient Floor
0' 3" 6" 0' 1'6" 2' 0' 1'6" 2' 0' 1'6" 2' 0' 1'6" 2'
0' 6"3" 12" 0' 6"3" 12" 0' 6"3" 12"
1 1/2" = 1'-0"9
PARTIAL HEIGHT WALL DETAIL
0' 6"3" 12"
3" = 1'-0"10 FLOOR - Cove Base Detail
0' 3" 6"
1 1/2" = 1'-0"11 FLOOR - Shower Floor Detail
0' 6"3" 12"
1 1/2" = 1'-0"12
TYPICAL CEILING LIFT MOUNTING DETAIL - AT H-TRACK
1 1/2" = 1'-0"13
TYPICAL CEILING LIFT MOUNTING DETAIL - AT BATHROOM TRACK
3/4" = 1'-0"14
TYPICAL CEILING LIFT PENETRATION DETAIL
0' 6"3" 12"0' 6"3" 12" 0' 1'-0"6" 2'-0"
NOTE: SEE MILLWORK
GENERAL NOTES FOR
CABINET CONSTRUCTION
BACKSPLASH-ENDSPLASH
WHERE MILLWORK ABUTS WALL
FILE HANGER BAR - EACH
SIDE - TYP.
4" WIRE PULLS TO BE
MOUNTED 2" FROM TOP OF
DRAWER AND CENTERED ON
WIDTH OF DRAWER
SCHEDULED BASE
WOOD BLOCKING
CONTINUOUS CAULK
3"
/8
E Q
/8
E Q
V A
R
IE
S
S E
E E
L E
V A
T
IO
N
AI541
U.N.O.
2' - 0"
WIRE PULL TO BE
CENTERED HORIZONTALLY
AND VERTICALLY ON FACE
OF DRAWER
WOOD BLOCKING
ADJUSTABLE SHELF
BACK PANEL TO BE FACED IN MELAMINE
ALL SIDES OF DOOR TO BE
FACED IN PLASTIC LAMINATE
FRONT LATERAL BRACE
BACKSPLASH-ENDSPLASH
WHERE MILLWORK ABUTS
WALL
CONTINUOUS CAULK
NOTE: SEE MILLWORK
GENERAL NOTES FOR
CABINET CONSTRUCTION
WIRE PULL CENTERED BOTH
HORIZONTALLY AND VERTICALLY
ON DRAWER
WIRE PULL
4"
3"
SCHEDULED BASE
2' - 0"
/4
/8
V A
R
IE
S
S E
E E
L E
V A
T
IO
N S
AI541
BACKER SHEET (TYP)
FOR UNEXPOSED SURFACES
MOUNT OUTLET IN MILLWORK;
COORDINATE WITH ELECTRICAL
MICROWAVE. VERIFY SIZE AND
MANF. INSTALLATION PRIOR TO
FABRICATION OF MILLWORK TO
CONFIRM SHELF DEPTH REQUIRED
BY MICROW AVE.
3"
/8
/8
V A
R
IE
S
S E
E E
L E
V A
T
IO
N
BACKSPLASH-ENDSPLASH
WHERE MILLWORK ABUTS
WALL
CONTINUOUS CAULK
4" WIRE PULL CENTERED
HORIZONTALLY ON DRAWER
SCHEDULED BASE
INTERIOR FINISH OF MILLWORK
SHOULD MATCH EXTERIOR
2' - 0"
WOOD BLOCKING
AI541
WOOD BLOCKING
BACK PANEL TO BE FACED IN MELAMINE
ALL SIDES OF DOOR TO BE
FACED IN PLASTIC LAMINATE
FRONT LATERAL BRACE
BACKSPLASH-ENDSPLASH
WHERE MILLWORK ABUTS
WALL
CONTINUOUS CAULK
NOTE: SEE MILLWORK
GENERAL NOTES FOR
CABINET CONSTRUCTION
WIRE PULL
3"
SCHEDULED BASE
2' - 0"
/8
V
A R
IE
S
S
E E
E L E
V A
T
IO
N S
AI541
HANGING ROD
3"
WOOD BLOCKING
ADJUSTABLE SHELF
BACK PANEL TO BE FACED IN MELAMINE
ALL SIDES OF DOOR TO BE
FACED IN PLASTIC LAMINATE
FRONT LATERAL BRACE
BACKSPLASH-ENDSPLASH
WHERE MILLWORK ABUTS
WALL
CONTINUOUS CAULK
NOTE: SEE MILLWORK
GENERAL NOTES FOR
CABINET CONSTRUCTION
WIRE PULL CENTERED BOTH
HORIZONTALLY AND VERTICALLY
ON DRAWER
WIRE PULL
4"
3"
SCHEDULED BASE
2' - 0"
/4
/8
V A
R
IE
S
S E
E E
L E
V A
T
IO
N S
AI541
SAFE, OFCI, ANCHORED TO CASEWORK
FINISHED END PANEL, PLASTIC
LAMINATE ON 3/4" HIGH
DENSITY FIBERBOARD
UNDER-COUNTER
EQUIPMENT (N.I.C.) -
COORDINATE WITH EQUIPMENT
BACK AND SIDE PANELS
TO BE FACED IN LAMINATE TO
MATCH ADJACENT BASE
CABINET
COORDINATE ELECTRICAL W/
ELECTRICAL DRAWINGS
NOTE: SEE MILLWORK
GENERAL NOTES FOR
CABINET CONSTRUCTION
BACKSPLASH-ENDSPLASH WHERE
MILLWORK ABUTS WALL
CONTINUOUS CAULK
2' - 0"
V A
R
IE
S
S E
E E
L E
V A
T
IO
N
SCHEDULED BASE
WOOD BLOCKING
SCHEDULED BASE
2" WIDE FILLET OVER EACH
LONGITUDINAL BRACE AND ALL
SIDE/END PANELS
BACKSPLASH-
ENDSPLASH
WHERE MILLWORK
ABUTS WALL
NOTE: SEE MILLWORK
GENERAL NOTES FOR
CABINET CONSTRUCTION
V A
IR
E
S S
E E
E L
E V
A T
IO
N
U.N.O.
2' - 0"
CONTINUOUS CAULK
/2
MAX.
9" LC DRAIN
REFER TO PLUMBING
DRAWINGS FOR SINK AND
FAUCET SPECIFICATION
REMOVABLE RADIUS PANEL
ON "Z" CLIPS OR HINGED,
TO BE FACED IN PLASTIC
LAMINATE
6"
.9
LINE OF STRAIGHT
PANEL BEYOND
BLOCKING AS REQUIRED
ADJUSTABLE SHELVES,
SEE ELEVATIONS FOR QUANTITY
DOORS FACED IN PLASTIC LAMINATE
TO MATCH BASE CABINET BELOW, U.N.O.
RECESSED STANDARDS
BACK PANEL TO BE FACED IN MELAMINE
NOTE: SEE MILLWORK
GENERAL NOTES FOR
CABINET CONSTRUCTION
ANGLED FILLER PANEL (WHERE INDICATED)
V A
R
IE
S
S E
E E
L E
V A
T
IO
N
AI541
CLEAR, U.N.O.
1' - 3"
WIRE PULL
DOOR
FACE OF SHIM TO BE
PAINTED BLACK
WALL
SLOPED FILLER PANEL
SEE ELEVATIONS
FOR LOCATIONS
NOTE: SEE MILLWORK
GENERAL NOTES FOR
CABINET CONSTRUCTION
/2
6"
FINISH TO MATCH
CABINET DOOR
DOOR
4" W IRE PULL
FINISH FASCIA PANEL
BLOCKING AS REQ'D.
FINISH EXPOSED SURFACES
1"
/4
BACK PANEL
1' - 0" 1"
1' - 1"
BASE AS SCHEDULE
NOTE: SEE MILLWORK
GENERAL NOTES FOR
CABINET CONSTRUCTION
WOOD BLOCKING
INTERIOR FINISH-
MELAMINE U.N.O.
3"
4"
SOLID SURFACE
SEALANT
SUBSTRATE
BACKSPLASH -
ENDSPLASH WHERE
MILLWORK ABUTS
WALL
CONTINUOUS
SEALANT TO MATCH SOLID
SURFACE COLOR
NOTE: SEE MILLWORK
GENERAL NOTES FOR
CABINET CONSTRUCTION
VARIES - SEE PLAN
BULLNOSE EDGE
1"
/2
ADJUSTABLE SHELVES,
SEE ELEVATIONS FOR QUANTITY
DOORS FACED IN PLASTIC LAMINATE
TO MATCH BASE CABINET BELOW, U.N.O.
BACK PANEL TO BE FACED IN MELAMINE
NOTE: SEE MILLWORK
GENERAL NOTES FOR
CABINET CONSTRUCTION
WIRE PULL
METAL STUDS
5/8" GYP BD
(2) UTILITY HOOKS SPACED 24" OC, MINIMUM 30 LB CAPACITY PER HOOK
EVACUATION SLEDS, OFOI
BASE AS SCHEDULED
3'
3'
4"
1' - 0 3/4"
WALL BEYOND
3'
LED LIGHT SOURCE, SEE ELECTRICAL DRAWINGS FOR SPECIFICATION.
PLASTIC LAMINATE PANEL
FRAMING AS REQUIRED
SSM-2 TRANSACTION TOP
9 1/2"
3"
2'
WORK SURFACE PROVIDED BY OTHERS
BRUSHED STAINLESS STEEL TOEKICK,
TERMINATE TO INSIDE CORNER AT W ALL
PLASTIC LAMINATE PANEL
SSM-1 TOP CAP
FRAMING AS REQUIRED
2'
WORK SURFACE PROVIDED BY OTHERS
BRUSHED STAINLESS STEEL TOEKICK
WRAP TOEKICK AND TERMINATE AT INSIDE
CORNER OF KNEE SPACE
PLASTIC LAMINATE PANEL
SSM-1 TOP CAP
FRAMING AS REQUIRED
BRUSHED STAINLESS STEEL TOEKICK
7"
PLAM-2 END PANEL WITH
LIGHT SOURCE COVERED
TRANSACTION TOP BEYOND
PLAM-2 END PANEL FOR TRANSACTION TOP
WORKSURFACE PROVIDED BY OTHERS
SCHEDULED BASE
2" WIDE FILLET OVER EACH
LONGITUDINAL BRACE AND ALL
SIDE/END PANELS
BACKSPLASH-ENDSPLASH
WHERE MILLWORK
ABUTS WALL, EXTENDED TO
BOTTOM UP WALL CABINET
NOTE: SEE MILLWORK
GENERAL NOTES FOR
CABINET CONSTRUCTION
V A
IR
E
S S
E E
E L
E V
A T
IO
N
U.N.O.
2' - 0"
CONTINUOUS CAULK
/2
MAX.
9"
LC DRAIN
REFER TO PLUMBING
DRAWINGS FOR SINK AND
FAUCET SPECIFICATION
REMOVABLE RADIUS PANEL
ON "Z" CLIPS OR HINGED,
TO BE FACED IN PLASTIC
LAMINATE
6"
.9
LINE OF STRAIGHT
PANEL BEYOND
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N A
11389
C
UL
LEN
S . KEEN
C H A R
LOTTE , NORTH
CA
RO
L
IN
A
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS PROJECT
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:1
P
M
AI541
CASEWORK DETAILS
11 17RP/CK CK/AB
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 6/28/2019
BID DOCUMENTS
558-18-150
1" = 1'-0"2 CASEWORK - Base Cabinet w/ Box,Box,File
1" = 1'-0"1 CASEWORK - Base Cabinet w/Drawer
1" = 1'-0"3 CASEWORK - Base Cabinet w/Drawer & Shelf for Equip.
1" = 1'-0"4 CASEWORK - Base Cabinet w/ Hanging Rod
1" = 1'-0"5 CASEWORK - Base Cabinet w/Drawer and Safe
1" = 1'-0"6 CASEWORK COUNTER - Counter w/ Equipment
1" = 1'-0"7 CASEWORK SINK - Sink w/Enclosed Apron - ADA
1" = 1'-0"8 CASEWORK - Wall Cabinet, 2 Shelf, 1 DO, Sloping Top
3" = 1'-0"13 CASEWORK DETAIL - Typical Sloped Filler Panel Detail
3" = 1'-0"14 CASEWORK DETAIL - Typical Wire Pull Detail
3" = 1'-0"15 CASEWORK DETAIL - Typical Toe Kick Detail
6" = 1'-0"16 CASEWORK DETAIL - Typical Solid Surface Counter w/Bullnose Detail
0' 3" 6" 0' 3" 6" 0' 3" 6" 0' 1.5" 3"
0' 1'6" 2'
0' 1'6" 2'
0' 1'6" 2'
0' 1'6" 2' 0' 1'6" 2' 0' 1'6" 2' 0' 1'6" 2' 0' 1'6" 2'
1" = 1'-0"9 CASEWORK - Full Height PPE Cabinet
1" = 1'-0"10
CARE STATION FRONT - B
0' 1'6" 2' 0' 1'6" 2'
1" = 1'-0"11
CARE STATION END WALL
1" = 1'-0"12
CARE STATION FRONT - A
0' 1'6" 2' 0' 1'6" 2'
1" = 1'-0"17 CASEWORK SINK - Sink w/EncL. Apron and High Backsplash - ADA
0' 1'6" 2'
D3
WOOD
OPPOSING DOOR
D2
WOOD
D4
WOOD
UNEVEN PANELS
WOOD
D1
S E
E S
C H
E D
U
LE
SEE SCHEDULE
S E
E S
C H
E D
U
LE
SEE SCHEDULE
10"3"
1'
2'
S E
E S
C H
E D
U
LE
SEE SCHEDULE
10"3"
1'
2'
S E
E S
C H
E D
U
LE
SEE SCHEDULE
2' - 0"
HOLLOW METAL FRAME
F1
HOLLOW METAL FRAME
CASED OPENING
F2
S E
E S
C H
E D
U
LE
2"
2" SEE SCHEDULE 2"
S E
E S
C H
E D
U
LE
2"
2" SEE SCHEDULE 2"
HOLLOW METAL FRAME
SPLIT HEAD FOR CEILING LIFT
F3
S E
E S
C H
E D
U
LE
2"
2" SEE SCHEDULE 2"
EQ
SPLIT HEAD - REF TO 5/A601
EQ
1/4" TEMPERED
GLAZING
5/16" FIRE-RATED
GLAZING
DOOR TYPES AND DOOR FRAME
D5
WOOD
UNEVEN PANELS
S E
E S
C H
E D
U
LE
SEE SCHEDULE
1' - 4"
1/2"
2"
VARIES
STEEL FRAME
SEALANT EACH SIDE
BOX HEADER
1/2"
2"
VARIES
STEEL FRAME
SEALANT EACH SIDE
BOX HEADER
VARIES
DOUBLE STUD
SEALANT EACH SIDE
STEEL FRAME
JAMB ANCHOR
2"
1/2" 1/2"
2"
VARIES
DOUBLE STUD
SEALANT EACH SIDE
STEEL FRAME
JAMB ANCHOR
SEALANT EACH SIDE
STEEL DOOR FRAME W/ CASED OPENING TOP (NO STOP)
WELDED FLUSH END CAP
CEILING AS
SCHEDULED
CEILING LIFT TRACK - VERIFY TRACK
CLEARANCE W/ MANUFACTURER
V E
R
IF
Y W
/ M F
R
3/
4"
1/ 2"
V E
R
IF
Y W
/ M F
R
2" VERIFY W/ MFR
TOP OF STEEL DOOR FRAME
4"
DOOR SCHEDULE NOTES:
1. PROVIDE SMOKE SEALS AT ALL DOORS IN SMOKE RESISTANT PARTITIONS.
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N A
A R
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N A
11389
C
UL
LEN
S . KEEN
C H A R
LOTTE , NORTH
CA
RO
L
IN
A
Revisions: Date
Drawing Title
Approved ANDREKA WATLINGTON
PROJECT ENGINEER
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS PROJECT
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
/2
/2
:1
:1
P
M
AI601
DOOR SCHEDULE AND DETAILS
12 17RP/CK CK/AB
IMPROVE INPATIENT
PRIVACY (RENOVATE 5B)
DURHAM VA MEDICAL CENTER
508 FULTON STREET
DURHAM, NC 27705 6/28/2019
BID DOCUMENTS
558-18-150
DOOR SCHEDULE
Door Number
Door
Elev Frame Type
Frame Material
Fire Rating
Hardw are
Type Comments
Size
MaterialWidth Height
B5003 3' - 0" 7' - 0" WD D1 F1 HM 90 MIN SH-3D CARD READER, ELEC LOCKSET
B5003A 3' - 0" 7' - 0" WD D1 F1 HM SH-3D CARD READER, ELEC LOCKSET
B5004 3' - 8" 7' - 0" WD D1 F1 HM 45 MIN SH-3D CARD READER, ELEC LOCKSET
B5007 6' - 0" 7' - 0" WD D4 F1 HM 10Z
B5007A 5' - 0" 7' - 11 3/4" WD D5 F3 HM 10Y DOOR/FRAME HEIGHT MUST BE COORDINATED W/ CEILING LIFT VENDOR
B5008 4' - 0" 7' - 0" WD D1 F1 HM 1B
B5008A 4' - 0" 7' - 11 3/4" WD D1 F3 HM 2C DOOR/FRAME HEIGHT MUST BE COORDINATED W/ CEILING LIFT VENDOR
B5010 4' - 0" 7' - 0" WD D1 F1 HM 1B
B5010A 4' - 0" 7' - 11 3/4" WD D1 F3 HM 2C DOOR/FRAME HEIGHT MUST BE COORDINATED W/ CEILING LIFT VENDOR
B5011 4' - 0" 7' - 0" WD D1 F1 HM 1B
B5011A 4' - 0" 7' - 11 3/4" WD D1 F3 HM 2C DOOR/FRAME HEIGHT MUST BE COORDINATED W/ CEILING LIFT VENDOR
B5012 6' - 0" 7' - 0" WD D4 F1 HM 10Z
B5012A 5' - 0" 7' - 11 3/4" WD D5 F3 HM 10Y DOOR/FRAME HEIGHT MUST BE COORDINATED W/ CEILING LIFT VENDOR
B5014 3' - 0" 7' - 0" WD D1 F1 HM SH-3D CARD READER, ELEC LOCKSET
B5014A 3' - 0" 7' - 0" WD D1 F1 HM 2C
B5015 3' - 0" 7' - 0" WD D1 F1 HM SH-3D CARD READER, ELEC LOCKSET
B5016 4' - 0" 7' - 0" WD D1 F1 HM 1B
B5016A 4' - 0" 7' - 11 3/4" WD D1 F3 HM 2C DOOR/FRAME HEIGHT MUST BE COORDINATED W/ CEILING LIFT VENDOR
B5017 3' - 8" 7' - 0" WD D1 F1 HM 45 MIN SH-3D CARD READER, ELEC LOCKSET
B5017A 3' - 0" 7' - 0" WD D1 F1 HM 5Z
B5018 3' - 6" 7' - 0" WD D1 F1 HM 45 MIN SH-3D CARD READER, ELEC LOCKSET
B5019 3' - 6" 7' - 0" WD D1 F1 HM 45 MIN SH-3D CARD READER, ELEC LOCKSET
B5020 3' - 0" 7' - 0" N/A N/A F2 HM N/A CASED OPENING
B5021 4' - 0" 7' - 0" WD D1 F1 HM 1B
B5021A 4' - 0" 7' - 11 3/4" WD D1 F3 HM 2C DOOR/FRAME HEIGHT MUST BE COORDINATED W/ CEILING LIFT VENDOR
B5022 4' - 0" 7' - 0" WD D1 F1 HM 1B
B5022A 4' -…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .