36C24620R0007-0006005.pdf

PDF Posted

Attached to
Inpatient Privacy Renovate 5B
Solicitation number
36C24620R0007
Issued by

About this file

This presolicitation notice announces an upcoming solicitation for commercial and institutional building construction services. The Department of Veterans Affairs requires renovating approximately 8,000 square feet of space on the fifth floor of the Durham VA Medical Center into twelve private patient rooms and ancillary spaces. The estimated construction value is between $1 million and $5 million. The solicitation will be a total service-disabled veteran-owned small business set-aside and is anticipated to publish around November 7, 2019, with proposals due approximately 45 days later. Interested parties should monitor the website for additional details.

36C24620R0007 0006 07-ELECRICAL_100_BD.1.pdf

View the file

Other files

File Type Posted
36C24620R0007-0011001.pdf PDF
36C24620R0007-0011002.pdf PDF
36C24620R0007-0011000.docx DOCX document
36C24620R0007-0010000.docx DOCX document
36C24620R0007-0009000.docx DOCX document
36C24620R0007-0008001.pdf PDF
36C24620R0007-0008000.docx DOCX document
36C24620R0007-0007000.docx DOCX document
36C24620R0007-0006004.pdf PDF
36C24620R0007-0006006.pdf PDF
36C24620R0007-0006000.docx DOCX document
36C24620R0007-0006003.pdf PDF
36C24620R0007-0006001.pdf PDF
36C24620R0007-0006002.pdf PDF
36C24620R0007-0005000.docx DOCX document
36C24620R0007-0005001.pdf PDF
36C24620R0007-0005005.pdf PDF
36C24620R0007-0005004.pdf PDF
36C24620R0007-0005002.pdf PDF
36C24620R0007-0005003.pdf PDF
36C24620R0007-0004000.docx DOCX document
36C24620R0007-0003000.docx DOCX document
36C24620R0007-0003001.pdf PDF
36C24620R0007-0002002.pdf PDF
36C24620R0007-0002001.docx DOCX document
36C24620R0007-0001001.pdf PDF
36C24620R0007-023.pdf PDF
36C24620R0007-022.docx DOCX document
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPECIAL PURPOSE RECEPTACLE - MOUNTED 18" AFF

QUADRUPLEX RECEPTACLE (HOSPITAL GRADE) - MOUNTED 18" AFF

LIGHTING CONTACTOR

a

PHOTOCELL

UTILITY KILOWATT-HOUR METER

DUPLEX RECEPTACLE (HOSPITAL GRADE) - EMERGENCY POWER -

MOUNTED 18" AFF

DUPLEX RECEPTACLE (HOSPITAL GRADE) - CEILING MOUNTED

QUADRUPLEX RECEPTACLE (HOSPITAL GRADE) - EMERGENCY

POWER - MOUNTED 18" AFF

MAGNETIC STARTER

SAFETY SWITCH - FUSIBLE

SAFETY SWITCH - NON-FUSIBLE

EQUIPMENT CONNECTION

EXIT SIGN - DUAL FACE, WALL MOUNTED

EXIT SIGN - DUAL FACE, CEILING MOUNTED

EXIT SIGN - SINGLE FACE, WALL MOUNTED

EXIT SIGN - SINGLE FACE, CEILING MOUNTED

ARROW INDICATES DIRECTION OF EXIT

BRANCH CIRCUIT PANELBOARD - FLUSH MOUNTED

DISTRIBUTION PANELBOARD OR SWITCHBOARD

MOTOR CONTROL CENTER

BRANCH CIRCUIT PANELBOARD - SURFACE MOUNTED

CONTROL PANEL

TRANSFORMER

POWER SYMBOLS LIGHTING SYMBOLS

AUTOMATIC TRANSFER SWITCH

CIRCUIT BREAKER

GROUND

ONE-LINE DIAGRAM SYMBOLS

GENERATOR

DELTA-WYE TRANSFORMER

HAND DRYER

CONDUIT - CAPPED

CABLE TRAY

SEALING FITTING

EXPANSION FITTING

CONDUIT FITTING (CONDULET)

JUNCTION BOX

CONDUIT - FLEXIBLE

CONDUIT - CONTINUED

CONDUIT - CONCEALED BELOW

SLAB OR GRADE

CONDUIT - UP AND DOWN

(CHANGE IN ELEVATION)

CONDUIT - TURNING UP

CONDUIT - EXPOSED

CONDUIT - CONCEALED IN

SUSPENDED CEILING OR WALL

CONDUIT - TURNING DOWN

REVISION CALL-OUT

ROOM NUMBER

FEEDER CALL-OUT

MECHANICAL EQUIPMENT CALL-OUT: REFER TO

THE EQUIPMENT DATA SCHEDULE FOR DETAILS

GENERAL SYMBOLS

WIRING AND CONDUITS

NEW EQUIPMENT (TYPICAL)

EXISTING EQUIPMENT (TYPICAL)

DEMOLITION EQUIPMENT (TYPICAL)

PUSH BUTTON

WALL MOUNT BRACKET (TYPICAL)

LUMINAIRE - SURFACE MOUNTED

OPEN INDUSTRIAL LUMINAIRE

RECESSED LUMINAIRE CONNECTED TO THE

EMERGENCY POWER SYSTEM

OPEN INDUSTRIAL LUMINAIRE

EMERGENCY POWER SYSTEM OR

BALLAST/DRIVER

LUMINAIRE TYPE

PANEL NAME

LUMINAIRE - RECESSED (REFER TO LUMINAIRE SCHEDULE)

CONNECTED FOR NIGHT LIGHT USE

1LP-1a NL

CIRCUIT NUMBER AND SWITCH LEG

(LUMINAIRES ARE CONTROLLED BY LOCAL

SWITCH UNLESS DESIGNATION GIVEN)

A a

WALL MOUNTED LUMINAIRE

a

T-1

45KVA 3Ø

480V-208Y/120VAC

# AF

# AT

PANELBOARD

QUADRUPLEX RECEPTACLE (HOSPITAL GRADE) -

MOUNTED 8" ABOVE COUNTER

LINEAR PENDANT

PENDANT

LRP LIGHTING RELAY PANEL

INV INVERTER

RECESSED DOWNLIGHT

EMERGENCY LIGHT

EXIT SIGN WITH EMERGENCY LIGHT

ARROW INDICATES DIRECTION OF EXIT

Room name 101A

PLUMBING EQUIPMENT CALL-OUT: REFER TO

THE EQUIPMENT DATA SCHEDULE FOR DETAILS

J

G

# A

# POLES

VOLTS

PANEL

M

F

VFD

T

POLE MOUNTED TRANSFORMERT

J

H

B

DUPLEX RECEPTACLE (NEMA 5-20R) (HOSPITAL GRADE) -

MOUNTED 18" AFF

GFI GROUND FAULT CIRCUIT INTERRUPTER

SS SURGE SUPPRESSOR (ISOLATED GROUND TYPE)

WP WEATHERPROOF

TP TAMPER PROOF

DED DEDICATED

AC MOUNT 8" ABOVE COUNTER

FLOOR BOX - SEE SPECS OR KEYED NOTES ON

PLAN FOR DETAILS

COMBINATION STARTER

VFD VARIABLE FREQUENCY DRIVE WITH INTEGRAL

DISCONNECTING DEVICE

PC

LC1

TOGGLE SWITCH - MOUNTED 48" AFF

b LOWER CASE LETTER DENOTES LTG. SWITCH GROUP

2 DOUBLE-POLE SINGLE-THROW (DPST)

3 3-WAY

4 4-WAY

B PUSHBUTTON

D DIMMER (WALL BOX TYPE)

K KEY OPERATED

M MANUAL MOTOR STARTER

P PILOT LIGHT

T TIMER

TT THERMAL TRIP SWITCH

WP WEATHERPROOF

OS WALL BOX OCCUPANCY SENSOR

OS2 WALL BOX OCCUPANCY SENSOR FOR TWO LEVEL

SWITCHING

VS WALL BOX VACANCY SENSOR

LV LOW VOLTAGE SWITCH

LVD LINE VOLTAGE DIMMER

LVDS LINE VOLTAGE DIMMER WITH INTEGRAL VACANCY SENSOR

OS

DL

CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR

a LOWER CASE LETTER DENOTES LTG. SWITCH GROUP

CEILING MOUNTED DAYLIGHT SENSOR

a LOWER CASE LETTER DENOTES LTG. SWITCH GROUP a

VS CEILING MOUNTED DUAL TECHNOLOGY VACANCY SENSOR

a LOWER CASE LETTER DENOTES LTG. SWITCH GROUP

GROUND BAR

100A4G

# KVA/KW

480Y/277V, 3Ø, 4W

CLNG

AC

AHU-1

GWH1

E

ELECTRICAL ABBREVIATIONS LIST

SS STAINLESS STEEL

SSW SELECTOR SWITCH

STD STANDARD

SURF SURFACE MOUNTED

SW SWITCH

SWBD SWITCHBOARD

SYM SYMMETRICAL

SYS SYSTEM

TC TIMECLOCK

TEL TELEPHONE

TEL/DATA TELEPHONE/DATA

TERM TERMINAL

TP TWISTED PAIR

TPS TWISTED PAIR SHIELDED

TR TAMPER RESISTANT

T-STAT THERMOSTAT

TTB TELEPHONE TERMINAL BOARD

TTC TELEPHONE TERMINAL CABINET

TV TELEVISION

TYP TYPICAL

UC UNDER COUNTER

UE UNDERGROUND ELECTRICAL

UG UNDERGROUND

UH UNIT HEATER

UL UNDERWRITER'S LABORATORY

UNO UNLESS NOTED OTHERWISE

UT UNDERGROUND TELEPHONE

UTP UNSHIELDED TWISTED PAIR

UTIL UTILITY

UV UNIT VENTILATOR OR

ULTRAVIOLET

V VOLT

VA VOLT-AMPERES

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VOL VOLUME

W WATT

W/ WITH

WH WATER HEATER

W/O WITHOUT

WP WEATHERPROOF

XFMR TRANSFORMER

XFR TRANSFER

ANGLE

@ AT

DELTA

' FEET

" INCHES

# NUMBER

Φ PHASE

C CENTER LINE

P PLATE

N NEW, THIS PROJECT

NA NOT APPLICABLE

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURER'S ASSOCIATION

NFDS NON-FUSED SAFETY DISCONNECT

SWITCH

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NORMALLY OPEN

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OH OVERHEAD

OL OVERLOAD

PA PUBLIC ADDRESS

PB PULL BOX OR PUSHBUTTON

PBPU PREFABRICATED BEDSIDE PATIENT

UNIT

PCB POLYCHLORINATED BYPHENYL

PC PHOTOELECTRIC CELL

PED PEDESTAL

PEND PENDANT

PF POWER FACTOR

PH PHASE

PIV POST INDICATING VALVE

PNL PANEL

POE POWER-OVER-ETHERNET

PR PAIR

PRI PRIMARY

PROJ PROJECTION

PRV POWER ROOF VENTILATOR

PT POTENTIAL TRANSFORMER

PVC POLYVINYL CHLORIDE (CONDUIT)

PWR POWER

QTY QUANTITY

RCP REFLECTED CEILING PLAN

RCPT RECEPTACLE

REQD REQUIRED

RGS RIGID GALVANIZED STEEL

RM ROOM

RMS ROOT MEAN SQUARE

RTU ROOF TOP UNIT

SC SURFACE CONDUIT

SEC SECONDARY

SF SQUARE FEET/FOOT

SHT SHEET

SI INTERNATIONAL SYSTEM OF UNITS

SIM SIMILAR

S/N SOLID NEUTRAL

SPEC SPECIFICATION

SPKR SPEAKER

SP SPARE

SR SURFACE RACEWAY

1P 1 POLE (2P, 3P, 4P, ETC.)

1PH 1 PHASE

2/C TWO-CONDUCTOR (3/C, 4/C, ETC.)

W2 TWO-WIRE (3W, 4W, ETC.)

3PH 3 PHASE

A AMPERE

AAP ALARM ANNUNCIATOR PANEL

AC ABOVE COUNTER

AIR CONDITIONER

ALTERNATING CURRENT

ACC ACCESSIBLE

ACLG ABOVE CEILING

ADO AUTOMATIC DOOR OPENER

A/E ARCHITECT/ENGINEER

AF AMP FRAME

AFC AVAILABLE FAULT CURRENT (KILOAMPS)

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFI ARC FAULT CIRCUIT INTERRUPTER

AHJ AUTHORITY HAVING JURISDICTION

AHU AIR HANDLING UNIT

AIC AMPERE INTERRUPTING CAPACITY

AL ALUMINUM

ALT ALTERNATE

AMP AMPERE

APPROX APPROXIMATELY

ARCH ARCHITECT, ARCHITECTURAL

AT AMP TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIO VISUAL

AWG AMERICAN WIRE GAUGE

BAS BUILDING AUTOMATION SYSTEM

BATT BATTERY

BC BARE COPPER

BD BOARD

BFF BELOW FINISHED FLOOR

BLDG BUILDING

BMS BUILDING MANAGEMENT SYSTEM

BYP BYPASS

C CONDUIT

CAB CABINET

CALC CALCULATED

CAP CAPACITY

CAT CATALOG, CATEGORY

CATV COMMUNITY ANTENNA TELEVISION

CB CIRCUIT BREAKER

CCR CONTROL CONTACTOR

CCTV CLOSED CIRCUIT TELEVISION

cd CANDELA

CD CONSTRUCTION DOCUMENTS

CF CONTRACTOR-FURNISHED

CKT CIRCUIT

CLG CEILING

COAX COAXIAL CABLE

COMM COMMUNICATION

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUATION OR CONTINUOUS

CONTR CONTRACTOR

COORDCOORDINATE

COR CONTRACTING OFFICER

REPRESENTATIVE

CPT CONTROL POWER TRANSFORMER

CRI COLOR RENDERING INDEX

CT CURRENT TRANSFORMER

CTV CABLE TELEVISION

CTR CENTER

CU COPPER

CU FT CUBIC FEET

dB DECIBEL

DB DIRECT BURIAL

DC DIRECT CURRENT

DEG C DEGREES CELSIUS

DEG F DEGREES FAHRENHEIT

DEMO DEMOLISH/DEMOLITION

DEPT DEPARTMENT

DIA DIAMETER

DISC DISCONNECT

DIST DISTRIBUTION

DN DOWN

DS SAFETY DISCONNECT SWITCH

DT DOUBLE THROW

DWG DRAWING

EC ELECTRICAL CONTRACTOR

EG EQUIPMENT GROUND

ELEC ELECTRIC, ELECTRICAL

ELEV ELEVATOR

EM EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMS ENERGY MANAGEMENT SYSTEM

EMT ELECTRICAL METALLIC TUBING

EPO EMERGENCY POWER OFF

EQUIP EQUIPMENT

ESMT EASEMENT

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WALL HEATER

ELECTRIC WATER HEATER

EX EXISTING

EXP EXPLOSION PROOF

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FC FOOTCANDLE

FCU FAN COIL UNIT

FIXT FIXTURE

FLR FLOOR

FLUOR FLUORESCENT

FU FUSE

FUDS FUSED SAFETY DISCONNECT SWITCH

FVR FULL VOLTAGE REVERSING

FVNR FULL VOLTAGE NON-REVERSING

GAL GALLON

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERATOR

GFI GROUND FAULT CIRCUIT INTERRUPTER

GND GROUND

GRS GALVANIZED RIGID STEEL (CONDUIT)

GYP GYPSUM BOARD

HID HIGH-INTENSITY DISCHARGE

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HT HEIGHT

HTR HEATER

HV HIGH VOLTAGE

HVAC HEATING, VENTILATING AND AIR

CONDITIONING

IES ILLUMINATION ENGINEERING SOCIETY

IG ISOLATED GROUND

IMC INTERMEDIATE METAL CONDUIT

IR INFRARED

I/W INTERLOCK WITH

IWH INSTANTANEOUS WATER HEATER

J-BOX JUNCTION BOX

KV KILOVOLT

KVA KILOVOLT-AMPERE

KVAR KILOVOLT-AMPERE REACTIVE

KW KILOWATT

KWH KILOWATT HOUR

LED LIGHT-EMITTING DIODE

LF LINEAR FEET/FOOT

LM LUMEN

LRA LOCKED ROTOR AMPS

LT LIGHT

LTG LIGHTING

LTNG LIGHTNING

LV LOW VOLTAGE

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MC MECHANICAL CONTRACTOR

METAL-CLAD (CONDUIT)

MCA MINIMUM CIRCUIT AMPACITY

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MFR MANUFACTURER

MFS MAIN FUSED DISCONNECT SWITCH

MH MANHOLE

MIC MICROPHONE

MIN MINIMUM

MISC MISCELLANEOUS

MLO MAIN LUGS ONLY

MOA MULTIOUTLET ASSEMBLY

MSBD MAIN SWITCHBOARD

MT MOUNT

MTS MANUAL TRANSFER SWITCH

MTR MOTOR, MOTORIZED

L

L

A1 b

E1 c d

T1

'LPN'

ELECTRICAL SYMBOL NOTES

THE LIGHTING FIXTURE TYPE IS INDICATED BY AN UPPER CASE LETTER OR AN UPPER

CASE LETTER AND NUMBER.

THE SWITCH DESIGNATION (IF NEEDED) IS INDICATED BY A LOWER CASE LETTER.

EXAMPLE: LIGHTING FIXTURE TYPE 'A1' IS CONTROLLED BY SWITCH 'b'.

EXIT SIGNS: STEM INDICATES WALL MOUNTING. NO STEM INDICATES CEILING

MOUNTING. SHADED AREA INDICATES ILLUMINATED FACE(S). ARROW INDICATES

DIRECTIONAL ARROW ON ILLUMINATED FACE(S).

DEVICES: THE SWITCH DESIGNATION IS INDICATED BY A LOWER CASE LETTER.

THE CONTROL DEVICE DESIGNATION IS INDICATED BY A LOWER CASE LETTER.

TRANSFORMERS: THE TRANSFORMER TYPE IS INDICATED BY A NUMBER

FOLLOWING THE UPPER CASE LETTER 'T'. SEE THE TRANSFORMER SCHEDULE OR

THE SINGLE LINE DIAGRAM FOR THE TRANSFORMER DESCRIPTION AND

REQUIREMENTS.

PANELBOARDS: PANELBOARD DOORS MAY BE SHOWN TO INDICATE OPENING

SIDE OF RECESSED PANELBOARDS. SEE PANELBOARD IDENTIFICATION FOR

DESIGNATION CODES.

SHEET KEY NOTE: SEE THE SHEET KEY NOTES ON THAT SHEET FOR THE NOTE

NUMBER INDICATED IN THE HEXAGON.

HOME RUN TO BRANCH CIRCUIT PANEL: THE PANEL DESIGNATION AND CIRCUIT

DESIGNATION ARE SHOWN ADJACENT TO THE HOME RUN ARROW.

CIRCUIT BREAKER SIZES (AMPS/NUMBER OF POLES) ARE SHOWN IN THE PANEL

SCHEDULE WITH THE CORRESPONDING PANEL AND CIRCUIT DESIGNATION.

SYMBOL NOTATIONS: UPPER CASE LETTERS ADJACENT TO SYMBOLS INDICATE

A UNIT TYPE. SEE APPROPRIATE SCHEDULE OR SPECIFICATIONS.

'LPN'-1,3,5

EXAMPLE 1: WALL MOUNTED EXIT SIGN TYPE 'E1' WITH SINGLE FACE

AND DIRECTIONAL ARROW.

EXAMPLE 2: CEILING MOUNTED EXIT SIGN TYPE 'E2' WITH DOUBLE

FACE AND DIRECTIONAL ARROWS.

E2

EXAMPLE: SPLIT DUPLEX RECEPTACLE; ONE RECEPTACLE OUTLET IS

CONTROLLED BY SWITCH 'c'.

EXAMPLE: SINGLE POLE SWITCH 'd' TO CONTROL LIGHTING FIXTURES INDICATED BY 'd'.

EXAMPLE: TRANSFORMER TYPE 'T1'.

EXAMPLE: HOME RUN TO PANELBOARD 'LPN'; CIRCUITS 1, 3, 5.

# DEMOLITION KEY NOTE: SEE THE SHEET KEY NOTES ON THAT SHEET FOR THE

NOTE NUMBER INDICATED IN THE SQUARE.

GENERAL ELECTRICAL NOTES

1. ALL ELECTRICAL DEVICES, FIXTURES, EQUIPMENT AND FEEDERS SHALL BE INSTALLED IN

ACCORDANCE WITH THE PROJECT SPECIFICATIONS, THE MANUFACTURER'S RECOMMENDED

PROCEDURES, ALL APPLICABLE LOCAL AND STATE CODES, AMERICANS WITH DISABILITIES ACT AND

WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND VA STANDARDS.

2. PROVIDE ADDITIONAL SUPPORT FOR DEVICES, FIXTURES, EQUIPMENT AND FEEDERS WHERE THE

BUILDING CONSTRUCTION IS NOT SUITABLE FOR DIRECT MOUNTING.

3. FIRESTOP, DRAFTSTOP, SMOKESTOP AND/OR PROTECT THE ANNULAR SPACE AROUND ALL

PENETRATIONS THROUGH WALLS, PARTITIONS, FLOORS, CEILING, AND ROOFS IN ACCORDANCE

WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, UL LISTING REQUIREMENT AND

THE APPLICABLE BUILDING CODES.

4. VERIFY CEILING SYSTEMS AND PROVIDE MOUNTING ACCESSORIES, TRIMS AND ALL REQUIRED

MOUNTING HARDWARE TO SUIT THE PARTICULAR INSTALLATION.

5. PROTECT EXISTING UNDERGROUND AND BUILDING INTERIOR UTILITIES DURING CONSTRUCTION.

6. BRANCH CIRCUIT CONDUCTORS SHALL BE 12 AWG COPPER MINIMUM.

7. COORDINATE ANY AND ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION SO AS TO

AVOID CONFLICT DURING CONSTRUCTION.

8. ALL PANELS SHALL HAVE TYPED, COMPLETED DIRECTORIES INDICATING EQUIPMENT SERVED AND ROOM NUMBER (AS INDICATED ON FINAL BUILDING ROOM SIGNAGE) OF EQUIPMENT LOCATION, OR SPARE, OR SPACE. ALL DEVICES/EQUIPMENT LOCATIONS SHALL BE LABELLED IDENTIFYING FEEDER

AND ELECTRICAL CIRCUIT DESIGNATION.

9. MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE PURPOSES, TO

INDICATE A QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A PARTICULAR

MANUFACTURER. PRODUCTS DEEMED EQUAL AND APPROVED BY THE DESIGNER WILL BE

ACCEPTED. ALL PRODUCTS MUST COMPLY WITH "BUY AMERICAN ACT".

10. ALL FEEDERS AND CIRCUITRY SHALL BE TORQUED PER THE PANEL, BREAKER, AND/OR PARTICULAR

EQUIPMENT MANUFACTURER'S SPECIFICATIONS.

11. CIRCUITRY TO SWITCHES, RECEPTACLES, AND ALL OTHER DEVICES SHALL BE TERMINATED ON THE

DEVICE'S SCREW TERMINALS.

12. MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, OUTLET, FIXTURE, OR EQUIPMENT

UNLESS NOTED OTHERWISE.

13. ALL WIRE TERMINATIONS SHALL BE RATED FOR 75 DEGREES C.

14. ALL CONDUCTORS SHALL HAVE THHN/THWN INSULATION, UNLESS OTHERWISE NOTED.

15. ALL CONDUIT SHALL BE RGS OR EMT UNLESS OTHERWISE NOTED. FMC CONDUIT SHALL BE USED ON

VIBRATING EQUIPMENT (MAXIMUM LENGTH OF 6 FEET).

16. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT SHALL BE LABEL LISTED BY AN

APPROVED THIRD PARTY TESTING AGENCY.

17. FOR ALL LED FIXTURES, THE FIXTURE MUST BE CAPABLE OF SELF-RESETTING TO THE

SWITCHED/CONTROLLED STATE DURING ANY FLUCTUATION IN POWER SUPPLY WHERE AUTOMATIC

PROTECTIVE MEASURES DISABLE THE LED LAMPS. PROVIDE A LETTER OR STATEMENT FROM THE

MANUFACTURER, OR OTHER ACCEPTABLE PROOF, THAT ALL LED FIXTURES, WITH OR WITHOUT

BROWNOUT PROTECTION, WILL RETURN TO THE SWITCHED/CONTROLLED STATE AUTOMATICALLY.

PROVIDE STATEMENT WITH THE FIXTURE SUBMITTALS.

18. IN CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE CONTRACT DRAWINGS, THE

BETTER QUALITY, MORE STRINGENT REQUIREMENTS OR GREATER QUANTITY OF WORK , AS

DETERMINED BY THE GOVERNMENT, SHALL BE PROVIDED.

19. COMPRESSION COUPLINGS SHALL BE USED. NO SET SCREW FITTINGS ARE ALLOWED.

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:0

:4

P

M

E-001

ELECTRICAL GENERAL INFORMATION

1 16MAH JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

ELECTRICAL SYMBOL LEGEND

N

R

A

N

046636

E

E N

I

G

H

K

I

A

W

O

N

A

T

R

F

SEAL

R

P

O

O

I

SS

O E

H

RC

A

I

L

A

N

L

E

N

C

I

M

H

E

A

L

S

C5010A

C5012

SURG RISK

ASSESSMENT NURSE

HOUSE

KEEPING

ELEVATOR

ELEVATOR

G

FI

G

FI

G

FI

GFIGFI

GFI GFI

G

FI

G

FI

G

FI

J

G

FI

J J J J

J

J J

J

J J

J

J

J J

J

J

J

J

J

JJJ

J

J

J

J

J

JJ

J

GFI

G

FI G

FI

J J

JJ J

J

J

J

J

J J

J J

J

J

J

J

J

JJ

J

J

J

J

J

J

J

JJ

J

G

FI

J

J

J

J

GFI

LI

M

IT

O

F P

R O

JE

C

T S

C O

P E

L L

M M

N N

P P

Q Q

R R

R.1 R.1

5.1

5.1

8 9

13 14

14 15

SS

TT

TYP.

TYP. TYP.01

(EX)

MATV

CABINET

01 01

(EX)

FA TERMINAL

CABINET

TYP.

TYP.

TYP.

TYP.01

TYP.01

TYP.01

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:0

:1

P

M

ED101

FIFTH FLOOR ELECTRICAL

DEMOLITION PLAN

2 16MAH JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

0 4 8 16

NORTH

TRUE

Scale: 1/8" = 1'-0"

FIFTH FLOOR ELECTRICAL DEMOLITION PLAN

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

1. CONTRACTOR SHALL BE RESPONSIBLE FOR

TRACING AND IDENTIFYING ALL CIRCUITS AND

CONDUITS THAT ORIGINATE, PASS THROUGH,

OR TERMINATE IN THE AREA OF WORK.

DEMONLISH ALL CIRCUITS THAT ARE NO

LONGER IN USE. MAINTAIN CIRCUIT

CONTINUITY TO ALL CIRCUITS WHICH ARE

NOT COMPLETELY REMOVED.

2. CONTRACTOR TO DISCONNECT AND REMOVE

ELECTRICAL CONNECTION TO OUTLETS,

RECEPTACLES, HVAC EQUIPMENT AND

OTHER ELECTRICAL DEVICES. REMOVE

CONDUCTORS AND CONDUIT BACK TO

PANELBOARD SERVING EQUIPMENT OR TO

THE POINT WHERE OTHER REMAINING LOADS

ARE CONNNECTED. MARK ANY ABANDONED

OVERCURRENT PROTECTION DEVICE AS

"SPARE (UNUSED)".

3. ABANDONED CONDUIT/BOXES SHALL HAVE

ALL ELECTRICAL WIRING REMOVED

COMPLETELY AND NOT JUST MADE "SAFE".

CONDUIT/BOXES SHALL BE REMOVED WHERE

PRACTICAL WITHOUT CREATING ADDITIONAL

DEMOLITION WORK FOR OTHER TRADES.

CIRCUITS SUPPLYING EQUIPMENT WHICH IS

REMOVED UNDER THE CONTRACT

DOCUMENTS FOR ANY DIVISION SHALL, FOR

THE PURPOSES OF THIS NOTE, BE

CONSIDERED "ABANDONED".

4. WHERE CONDUIT IS REMOVED FROM AN

EXISTING RATED ASSEMBLY NOT SUBJECT TO

DEMOLITION, THE REMAINING PENETRATION

SHALL BE PATCHED/REPAIRED TO MAINTAIN

THE RATING OF THE ASSEMBLY.

5. DEMOLITIONS SHALL INCLUDE BUT NOT BE

LIMITED TO THOSE DEVICES AND OR

SYSTEMS NOTED. COORDINATE WITH

ARCHITECTURAL AND MECHANICAL

DEMOLITION PLANS FOR WORK SCOPE. FIELD

VERIFY EXISTING CIRCUITING. HEAVIER LINE

WEIGHT AND INDICATES DEMOLITION WORK.

LIGHTER LINE WEIGHT INDICATES EXISTING

TO REMAIN, VERIFY IN FIELD.

6. OWNER HAS FIRST RIGHT OF REFUSAL TO ALL

DEMOLITION ITEMS INCLUDING BUT NOT

LIMITED TO SMOKE/FIRE ALARM DEVICES, ALL

LIGHT FIXTURES AND, LAMPS OR RELATED

ASSEMBLIES. ANY ITEMS NOT IDENTIFIED BY

OWNER TO BE SAVED SHALL BE LEGALLY

DISPOSED OF IN ACCORDANCE WITH STATE

AND FEDERAL REGULATIONS.

01 (TYP) LED RETROFIT FIXTURE TO BE

REMOVED AND TURNED OVER TO VA

DURHAM. COORDINATE WITH COR.

02 EXISTING PANEL LF. REMOVE AND RELOCATE

TO NEW ELECTRICAL CLOSET B5017A. FIELD

VERIFY ANY EXISTING CIRCUITS NOT

REMOVED UNDER DEMOLITION FOR (5B),

EXTEND AND RELOCATE CIRCUITS TO NEW

PANEL LOCATION. SEE DETAIL 6 SHEET E-401.

kgenther Model

D E

D

AC

GFI

A C

G

FI

A C

G

FI

A C

G

FI

U S

B A

C

J

J J J

E

J

U S

B A

C

PATIENT RM

B5008

CARE STATION

B5009

PATIENT RM

B5010

PATIENT RM

B5011

PATIENT RM, BARIATRIC

B5012

LOCKER

B5014

PATIENT RM

B5016

SOILED UTILITY

B5018

STAFF LOUNGE

B5015

CLEAN SUPPLY

B5019

ALCOVE

B5020

PATIENT RM

B5021

PATIENT RM

B5022

PATIENT RM

B5024

PATIENT RM

B5025

PASSAGE

B5041

NOUR

B5026

MEDS

B5027

CORRIDOR

B5040

STAIR

B5050

STAFF TLT

B5014A

PATIENT RM, ISOLATION

B5028

BATH

B5028A

ANTE

B5028B

PATIENT RM, ISOLATION

B5029

BATH

B5029A

ANTE

B5029B

PATIENT RM, BARIATRIC

B5007

CARE STATION

B5005

EQUIP

B5004

CARE STATION

B5013

CARE STATION

B5023

NURSE MGR OFFICE

B5030EQUIP

B5017

TEAM WORK ROOM

B5031

ELEC

B5017A

OIT

B5003A

E-401

E-401

3 _____ E-401

E-401

4_____ E-401

E-401

E-401

L L

M M

N N

P P

Q Q

R R

R.1 R.1

5.1

5.1

8 9

13 14

14 15

SS

TT

(19) (21)

(21)

(19)

(19)

LF-17

LF-19,21

LF-31

ESCE-2

(GS1) LF-14

(GS2) LF-12

(EC) 5CE-13

(G51) LF-20

(GS2) LF-18

(EC) 5CE-7

(GS1) LF-10

(GS2) LF-12

(EC) 5CE-13

ESCE-2

(GS1) LF-16

(GS1) LF-18

(EC) 5CE-7

(GS1) LF-8

(GS2) LF-10

(EC) 5CE-5

LF-8

5CE-11

E5CD-7,9

LF-8

(GS1) LF-6

(GS2) LF-2

(EC) 5CE-3

(GS1) LF-4

(GS2) LF-2

(EC) 5CE-3

LF-2

LF-7

LF-9

B1-E5CE-1

(GS1) LF-3

(GS2) LF-5

(EC) 5CE-5

(GS1) LF-23

(GS2) LF-25

(EC) 5CE-10

(GS1) LF-27

(GS2) LF-25

(EC) 5CE-10

LF-27

5CE-1

(GS1) LF-32

(GS2) LF-30

(GS1) LF-28

(GS2) LF-30

(EC) 5CE-18

5CE-1

LF-1

LF-1

LF-13

LF-15

5CE-6

E5CE-1

BIO

B5003

LF-39

LF-11

02 (TYP)

02 (TYP)

02 (TYP)

(EC) 5CE-18

PNL-E5CT

LF-1

EWC

E5CE-9 E5CE-11

LF-8

LF-13

ESCE-22

R R

R.1 R.1

5.1

5.1

8 9

SS

TT

JJ

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/1

/2

:3

:1

A

M

EP101

FIFTH FLOOR POWER PLAN

3 16MAH JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

0 4 8 16

NORTH

TRUE

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

Scale: 1/8" = 1'-0"

FIFTH FLOOR POWER PLAN

A. PROVIDE 2 CRITICAL BRANCH E1 NORMAL

BRANCH 20A CIRCUITS FOR PATIENT

HEADWALL.

B. SEE -E401 FOR ELECTRICAL ROOM AND

CLOSET ENLARGEMENTS.

C. ALL CONDUCTORS SHALL BE 2-12 AWG, 1-12

AWG EG IN 3/4" CONDUIT UNLESS NOTED

OTHERWISE:

20-AMP CIRCUITS LESS THAN 150'

SHALL BE MINIMUM 2-12 AWG, 1-12 AWG

EG IN 3/4" C.

20-AMP CIRCUITS 150'-250' SHALL BE

MINIMUM 2-10AWG, 1-10 AWG EG IN

3/4" C.

20-AMP CIRCUITS GREATER THAN 250'

SHALL BE MINIMUM 2-8 AWG, 1-8 AWG

EG IN 3/4" C.

D. COORDINATE LOCATION AND ELECTRICAL

REQUIREMENTS OF MECHANICAL AND

PLUMBING EQUIPMENT WITH MECHANICAL AND

PLUMBING CONTRACTORS.

E. COORDINATE EQUIPMENT WITH

ARCHITECTURAL EQUIPMENT PLANS AND

SCHEDULES.

F. ELECTRICAL CONTRACTOR SHALL FOLLOW

SITE LOCK-OUT/ TAG-OUT GUIDELINES TO

DEENERGIZE EQUIPMENT.

G. ALL RECEPTACLES SHALL HAVE THEIR

SOURCE PANEL AND CIRCUIT NUMBER

INDICATED ON THEIR FACEPLATE.

H. SEE ENLARGED SCALE DETAIL PLANS SHEET

E-401 FOR DEVICE LOCATIONS IN PATIENT

ROOMS.

01 SEE SHEET GC001 FOR WORK SCOPE

RELATED TO ALTERNATE DEDUCT 1.

02 CIRCUITING FOR PATIENT ROOMS (TYP), SEE

DETAIL PLANS SHEET E-401.

03 SEE ARCHITECTURAL ELEVATIONS AND

DETAILS FOR DEVICE LOCATIONS.

04 POWER AT WALL JUNCTION BOX FOR

CONNECTION TO SYSTEMS FURNITURE.

PROVIDE CIRCUITS AS NOTED. COORDINATE

WITH VA FURNISHED SYSTEMS FURNITURE

AND PROVIDE COVER PLATE AT JUNCTION

BOX.

05 POWER FOR AUTOMATIC DOOR OPENER.

COORDINATE INTERCONNECTION WITH DOOR

CONTROL HARDWARE AND AETHON ROBOT

SYSTEM CONTROLS.

Scale: 1/8" = 1'-0"

FIFTH FLOOR POWER PLAN ALTERNATE DEDUCT 1 0 4 8 16

NORTH

TRUE

TO PNL LF

(B5017A)

1" C

TO PNL 5CE

(B5017A)

3/4" C

AETHON ROBOT DOOR INTERCONNECTIONS REVISION 08/15/2019

N

R

A

N

046636

E

E N

I

G

H

K

I

A

W

O

N

A

T

R

F

SEAL

R

P

O

O

I

SS

O E

H

RC

A

I

L

A

N

L

E

N

C

I

M

H

E

A

FG144A

EG017A

GENERAL

LAB

STORAGE

TO CRAWL

SPACE

TO CRAWL

RAMP

RAMP

BG000

BG001

AG002A

AG000A

AG002

CG008

S4

S5 P3

P2

P1 P7

P6

P5

AG005

AG009

AG011AG012

AG009A

AG008

AG015A

AG015B

AG003

CG009

CG007

CG010

BG003

FG145

FG146A

EG006

EG013

EG015

EG017

EG007

EG011

EG009

EG018

EG010

EG014

EG012

EG008

EG004

EG005

EG002

EG003

FG156

FG155

FG154

FG143

FG137A

FG147FG146 FG147A

FG142

FG148

FG149

FG157

FG158

FG104

FG160

FG160A

FG159

AG017

AG015

AG010

EG005A

EG007A

EG001

FG43

FG141

FG104A

FG156A

FG151

BG001A

AG001

EG003A EG003B

EG012A

EG018A

EG017A

FG1000

CG003

ROLLING

SHUTTER

UP

DN

STAIR-1

CANTEEN STORAGE

OFFICE

MORGUE

OFFICE

FREEZER

OFFICE

VENDING RM

KEEPING

CPR EQUIP

CANTEEN CANTEEN

OFFICE

FREEZER

STAIR-12

FIRE PROTECTION

HOUSE

ELECTRICAL RM

TELEPHONE

CLOSET

ISO OFFICE

KEEPING

OFFICE

LAB

OFFICE

OFFICE

OFFICE

STORAGE

STORAGE

STORAGE

RESEARCH

AFGE

AFGE

DECEDENT

AFFAIRS OFFICE ISO OFFICE

IRM OFFICE

CLOSET TOILET

SERVER RM

TELECOM

TELECOM

OFFICE

CLOSET

ELEVATOR

ELECTRICAL

HOUSE

LAB

FIRE PROTECTION

STORAGE

IRM OFFICE

STORAGE

CANTEEN

STAIR-10

HAC

DUMB WAITER

DUMB WAITER

GREEN

ELEVATOR

GREEN

ELEVATOR

GREEN

ELEVATOR

OFFICE

DUMB WAITER

FIRE PROTECTION

FIRE

CANTEEN

STORAGE

LINEN

CHUTE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

ELEVATOR

CAFETERIA

CAFETERIA

LINEN

CHUTE LINEN

CHUTE

SHAFT

MENS TOILET

TRASH RM

FEMALE TOILET

FEMALE TOILET

CORRIDOR

CORRIDOR

CORRIDOR

RETAIL STORE

MECH

RETAIL STORE

RECORDS RM

OFFICE, PRIVACY

CANTEEN DINING

CANTEEN DINING

CANTEEN DINING

KITCHEN

CANTEEN DINING

OFFICE

CORRIDOR

OFFICE, NURSING UNION ISO OFFICE

CORRIDOR

CORRIDOR

MECH RM

CORRIDOR

CORRIDOR

ELECTRICAL

ELECTRICAL

PROTECTION

446. 3969

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:0

:2

P

M

EP102

PARTIAL GROUND FLOOR ELECTRICAL

ROUTING PLANS

4 16MAH JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

Scale: 3/32" = 1'-0"

PARTIAL GROUND FLOOR ELECTRICAL ROUTING PLAN

01 EXISTING PANEL 'EED'. REFERENCE SINGLE

LINE SHEET E-601.

02 3" CONDUIT UP. REFERENCE SINGLE LINE

SHEET E-601.

03 FEEDER UP TO 5TH FLOOR. PROVIDE

FIRE/SMOKE RATED PENETRATIONS AS

REQUIRED BY CODE.

04 EXISTING SUBSTATION 120/208V, 3 PHASE, 4

WIRE.

05 ROUTING OF NEW RACEWAYS TO BE

COORDINATED WITH EXISTING CONDITIONS.

NO NEW RACEWAYS TO BE LOCATED BELOW

7'-6" ABOVE FINISHED FLOOR. REVIEW AND

NOTIFY COR OF CONFLICTS PRIOR TO

INSTALLATION FOR RESOLUTION.

A. COORDINATE ALL WORK WITH COR.

B. FOLLOW ALL ICRA GUIDELINES WHEN

PERFORMING WORK OUTSIDE PRIMARY AREA

OF WORK. COORDINATE WITH COR.

C. ELECTRICAL CONTRACTOR SHALL FOLLOW ALL

SITE LOCK-OUT/ TAG-OUT GUIDELINES TO

DEENERGIZE EQUIPMENT.

0 84 16

NORTH

TRUE

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

B1005

B1007 B1005A

B1003

A1009 A1011

C1010

C1024

C1014

C1012

C1008

C1018

C1006

B1001

C1030

B1001A

ELEVATOR

ELEVATOR

STAIR-1

ELEVATOR

ELEVATOR ELEVATOR

C10000

C1001

A1005

A1007

A1005A

A1005C

C1005

C1003

OFFICE

COFFE SHOP

WEAPON

OFFICE

ROOM

POLICE

RM

TRASH

CHUTE

OFFICE

IRB

TO PARKING GARAGE

OFFICE

TELEPHONE

OFFICE

OFFICE

OFFICE

OFFICE

STORAGE

GENERAL

DUMB

OFFICE

OFFICE

HAC

LINEN

CHUTE

P5

GREEN

ELEVATOR

P6

GREEN

ELEVATOR

P7

GREEN

ELEVATOR

LINEN/

BREAK

POLICE

A1005D

ROOM

HOLDING

KEEPING

HOUSE

CO-ORDR

FIRE PROTECTION

OFFICE

WAITER

DUMB

WAITER

C1008A

SVC

CUSTOMER

GENERAL

EVIDENCE

STORAGE

C1005A

ALCOVE

OIT

GENERAL

POLICE

STORAGE

STORAGE

A1007

B1003A

1CW4C

O

R R

ID

O

R

C O

R R

ID

O

R

C O

R R

ID

O

R

C W

C

W

1AW1CORRIDOR

C

W

C

W

CORRIDOR

C O

R R

ID

O

R

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:0

:2

P

M

EP103

PARTIAL FIRST FLOOR ELECTRICAL

ROUTING PLANS

5 16MAH JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

01 3" CONDUIT UP/DN. REFERENCE SINGLE LINE

ON SHEET E-601, AND ELECTRICAL ROUTING

PLANS.

Scale: 1/8" = 1'-0"

PARTIAL FIRST FLOOR ELECTRICAL ROUTING PLAN

A. COORDINATE ALL WORK WITH COR.

B. FOLLOW ALL ICRA GUIDELINES WHEN

PERFORMING WORK OUTSIDE PRIMARY AREA

OF WORK. COORDINATE WITH COR.

C. ELECTRICAL CONTRACTOR SHALL FOLLOW ALL

SITE LOCK-OUT/ TAG-OUT GUIDELINES TO

DEENERGIZE EQUIPMENT.

0 4 8 16

NORTH

TRUE

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

COOLER

SPD CLEAN STORAGE

STORAGE RM

STERILISATION

IMR OFFICEOFFICE

TOILET

TOILET

SPD STORAGE

CLOSET

OFFICE

OFFICE/LAB

OFFICE/LAB

LINEN /

LINEN CHUTE

SHAFT

DUMB WAITER

BREAKOUT

FIRE PROTECTION

MENS

WOMENS

LINEN

CORRIDOR

CORRIDOR

CORRIDOR

ANTE RM

CORRIDOR

RECEIVING AND

PROSTHETICS

OFFICE

TELEPHONE

TRASH CHUTE

CHUTE

CORRIDOR

CORRIDOR

CART STORAGE

SURGICAL SUPPLY AND

CLEAN

C2000

B2005A

B2003B

C2010

C2002

A2001

C2005

A2003

C2015

A2007

C2011

C2009

C2004

A2005

C2005B

C2007

A2007AA2005A

C2005A

A2005B

A

A

A2000B

DN

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:0

:2

P

M

EP104

PARTIAL SECOND FLOOR ELECTRICAL

ROUTING PLANS

6 16MAH JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

01 3" CONDUIT UP/DN. REFERENCE SINGLE LINE

ON SHEET E-601, AND ELECTRICAL ROUTING

PLANS.

Scale: 1/8" = 1'-0"

PARTIAL SECOND FLOOR ELECTRICAL ROUTING PLAN

A. COORDINATE ALL WORK WITH COR.

B. FOLLOW ALL ICRA GUIDELINES WHEN

PERFORMING WORK OUTSIDE PRIMARY AREA

OF WORK. COORDINATE WITH COR.

C. ELECTRICAL CONTRACTOR SHALL FOLLOW ALL

SITE LOCK-OUT/ TAG-OUT GUIDELINES TO

DEENERGIZE EQUIPMENT.

0 4 8 16

NORTH

TRUE

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

ANESTHESIOLOGY

CHECK-IN

CORRIDOR

OFFICE

COMPOSITE

DATA

OFFICE OFFICE

OFFICE

NURSING

EDUCATION

CLASS RM

STORAGE CONFERENCE RM

ELEVATOR

ELEVATOR ELEVATOR

ELEVATOR ELEVATOR

STAIR -1

CHAPEL

MEN

WOMENS

HOUSE

KEEPING

WAITING RM OFFICE OFFICE

ELEVATOR

ELEVATOR

ELEVATOR

DUMB WAITER

DUMB WAITER

LINEN CHUTE

STORAGE

DUMB WAITER

DUMB WAITER

STORAGE

OFFICE

ANESTHESIOLOGY

OFFICE

ANESTHESIOLOGY

OFFICE

OFFICE

OFFICE

OFFICE

TRASH CHUTE

LINEN

C3002

A3001A

C3011

A3011A3009A3007A3005

A3001

A3003

C3011A

C3003

C3007C3005

C3014

C3010

C3012C3008

C3006B

C3006A

C3004

C3000B3001

B3003D

B3003C

C3013A

C3013

A3000A

C3009

DN

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:0

:3

P

M

EP105

PARTIAL THIRD FLOOR ELECTRICAL

ROUTING PLANS

7 16MAH JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

01 3" CONDUIT UP. REFERENCE SINGLE LINE

ON SHEET E-601, AND ELECTRICAL ROUTING

PLANS.

02 3" CONDUIT DOWN. REFERENCE SINGLE

LINE ON SHEET E-601, AND ELECTRICAL

ROUTING PLANS.

Scale: 1/8" = 1'-0"

PARTIAL THIRD FLOOR ELECTRICAL ROUTING PLAN

A. COORDINATE ALL WORK WITH COR.

B. FOLLOW ALL ICRA GUIDELINES WHEN

PERFORMING WORK OUTSIDE PRIMARY AREA

OF WORK. COORDINATE WITH COR.

C. ELECTRICAL CONTRACTOR SHALL FOLLOW ALL

SITE LOCK-OUT/ TAG-OUT GUIDELINES TO

DEENERGIZE EQUIPMENT.

0 4 8 16

NORTH

TRUE

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

REC 9

REC 8 REC 7

A4001

C4009

C4005

C4001

C4016

C4007

C4014

C4012

C4010

C4004

C4008

C4002

B4001

B4003B4005

C4003

C4019

C4001B

C4001A

C4001C

C4012A

C4000

STAIR-1

NURSE OFFICE

ISOLATION RM

MACHINE

OR-1

OR-9 ANTE RM

ELEVATOR

ELEVATOR

ELEVATOR

ICE

PROTECTION

FIRE

DUMB WAITER DUMB WAITER

TOILET

MENS

STORAGE

HOUSE

KEEPING

DUMB WAITER

TOILET

GAS STORAGE

SHAFT

STORAGE

DUMB WAITER

PGM SUPPORT ASST

FIRE PROTECTION CLOSET

OR-8

LINEN/

TRASH CHUTE

LINEN CHUTE

HOUSE KEEPING

STAFF LOUNGE

ELEVATOR ELEVATOR

ELEVATOR ELEVATOR

ELEVATOR

CORRIDOR

TOILET

CORRIDOR

PACU

DUMB WAITER

DUMB WAITER

HOUSEKEEPING

EQUIPMENT

CLOS

C4006

ELECTRICAL

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:0

:3

P

M

EP106

PARTIAL FOURTH FLOOR ELECTRICAL

ROUTING PLANS

8 16MAH JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

01 EXISTING PANEL 'ELS4C'. ADD 40A, 3 POLE

BREAKER. REFERENCE SINGLE LINE SHEET

E-601.

02 3-6 AWG, 1-6 AWG NEUTRAL, 1-10 AWG EGC IN

1" CONDUIT. REFERENCE SINGLE LINE SHEET

E-601. PROVIDE FIRE-RATED PENETRATIONS

WHERE REQUIRED BY CODE.

03 3" CONDUIT. REFERENCE EP102-EP105.

Scale: 1/8" = 1'-0"

PARTIAL FOURTH FLOOR ELECTRICAL ROUTING PLAN

A. COORDINATE ALL WORK WITH COR.

B. FOLLOW ALL ICRA GUIDELINES WHEN

PERFORMING WORK OUTSIDE PRIMARY AREA

OF WORK. COORDINATE WITH COR.

C. ELECTRICAL CONTRACTOR SHALL FOLLOW ALL

SITE LOCK-OUT/ TAG-OUT GUIDELINES TO

DEENERGIZE EQUIPMENT.

0 4 8 16

NORTH

TRUE

OFFICE

STORAGE

OFFICE

DUMB WAITER

SURG RISK

ASSESSMENT NURSE

WORK RM

CHIEF

PLASTIC

SURGY

CHIEF

OTOLARYNGOLOGY

OFFICE

OFFICE

WOMENS

MALE

DUMP WAITER

CONFERENCE RM

SHAFT

FIRE PROTECTION CLOSET

HOUSE

KEEPING

GENERAL

STORAGE

STORAGE

CLOSET

DUMB WAITER ELEVATOR ELEVATOR

ELEVATOR ELEVATOR

OFFICE

CORRIDORSURG

OFFICE

EQUIPMENT

BEDS &

OFFICE

OFFICE

TO AREA

OF WORK

TO AREA

OF WORK B5002

A5002A

C5008

C5006

C5004

C5002

C5026

C5018

C5016

A5002B

C5010A

A5000

C5012

C5010

C5022

C5014A

3'-9 1 4"

C5028

C5014

A5001A

C5000

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

04 03

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:0

:3

P

M

EP107

PARTIAL FIFTH FLOOR ELECTRICAL

ROUTING PLANS

9 16MAH JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

Scale: 1/8" = 1'-0"

PARTIAL FIFTH FLOOR ELECTRICAL ROUTING PLAN

01 DOWN CONDUIT TO 4TH FLOOR. FEEDS NEW

PANEL 'LS'. REFERENCE SINGLE LINE SHEET

E-601.

02 DOWN CONDUIT. REFERENCE EP102-EP106.

03 3-6 AWG, 1-6 AWG NEUTRAL, 1-10 AWG EGC IN

1" CONDUIT. REFERENCE SINGLE LINE SHEET

E-601. (ELS5C)

04 3-4/0 AWG, 1-4/0 AWG NEUTRAL, 1-2 AWG EGC

IN 3" CONDUIT. REFERENCE SINGLE LINE

SHEET E-601. (E5CD, E5CE).

05 FEEDERS TO ELECTRICAL B5017A.

REFERENCE EP101, AND E-401

ENLARGEMENT 6.

06 EXISTING FA TERMINAL CABINET AND

WIREWAY.

A. COORDINATE ALL WORK WITH COR.

B. FOLLOW ALL ICRA GUIDELINES WHEN

PERFORMING WORK OUTSIDE PRIMARY AREA

OF WORK. COORDINATE WITH COR.

C. ELECTRICAL CONTRACTOR SHALL FOLLOW ALL

SITE LOCK-OUT/ TAG-OUT GUIDELINES TO

DEENERGIZE EQUIPMENT.

0 4 8 16

NORTH

TRUE

LVD

LV

D S

VSVS

LVD

LVD LVD LVDLVD

LVD

LVDS

LVD

LVDLVD

LVDLVD

LVD LVD

LVD

LVDLVD LVDLVD

LVD LVD

LVD

VS

LVDLVD

LVDLVD

LVDS

LVD

LVDS

LVD

LVD

LVD LVD

LVDS

LVDS

LVDS

LVDS

LVDS

LV

D

S

LV

D

S

LV

D

S

LV

D

S

LV

D

LV

D

LV

D

LV

D

LV

D

VS VS

V S

VS

LVD LVD LVD LVD

LVD

LVD

LVD

LVD

LVD

LVD

LVD

LV

D

SLV

D

J J

LI

M

IT

O

F P

R O

JE

C

T S

C O

P E

PATIENT RM

B5008

CARE STATION

B5009

PATIENT RM

B5010

PATIENT RM

B5011

PATIENT RM, BARIATRIC

B5012

LOCKER

B5014

PATIENT RM

B5016

SOILED UTILITY

B5018STAFF LOUNGE

B5015

CLEAN SUPPLY

B5019

ALCOVE

B5020

PATIENT RM

B5021

PATIENT RM

B5022

PATIENT RM

B5024

PATIENT RM

B5025

PASSAGE

B5041

NOUR

B5026 MEDS

B5027

BATH

B5007A

CORRIDOR

B5040

BATH

B5008A

BATH

B5010A

BATH

B5011A

BATH

B5016A

BATH

B5024A

BATH

B5025A

BATH

B5021A

STAIR

B5050

STAFF TLT

B5014A

PATIENT RM, ISOLATION

B5028

BATH

B5028A

ANTE

B5028B

PATIENT RM, ISOLATION

B5029

BATH

B5029A

PATIENT RM, BARIATRIC

B5007

CARE STATION

B5005

EQUIP

B5004

BATH

B5012A

CARE STATION

B5013

CARE STATION

B5023

NURSE MGR OFFICE

B5030

EQUIP

B5017 TEAM WORK ROOM

B5031

ELEC

B5017A

OIT

B5003A

E1

E1 E1

D1

D1

D1

D1

D1

D1

B1

B2

D1 D1 D1D1

D1 D1

D1 D1

D1

D1 D1

D1

D1 D1

D1 D1D1 D1D1 D1

D1

D1

D1 D1D1

B2

B2 B2

B1

B2 B2

B2B2

A1

A1

A1

A1

B1

B2

B2 B2 B2

B1 B1

D1

D1

D1

D1 D1

D2D2

D1D1

D1

D1

D1D1

D1

D1 D1

D1

D1

D1D1

D1

D1 D1

D1

D1

D2 D2

D1

D1D1

D2 D2

D1 D1

D1

D1D1D1 D1 D1

D1

D1 D1

D1

D2 D2 D2 D1

D1

D1

G G G G GC

NL/EM

G G G G

G

G

G

L L

M M

N N

P P

Q Q

R R

R.1 R.1

5.1

5.1

8 9

13 14

14 15

SS

TT

a a c aa

EM/NL

c b c cNL/EM

'ELS5C'-1

d d d d b e e e

EM/NL

NL/EM

'ELS5C'-1

EXISTING

STAIRWELL

LIGHTING

(EMERGENCY

LIGHTING

CIRCUIT)

NL/EM

'ELS5C'-1

NL/EM

'ELS5C'-1

NL/EM

'ELS5C'-1

'LF'-33 'LF'-33

'ELS5C'-2

'5CE'-3

C2 C1

C2

C2

C2 C2

C2

'5CE'-10

'5CE'-18

'5CE'-18

'5CE'-10

C2 C2

C2

'ELS5C'-2

D1

'LF'-34

'ELS5C'-2

'LF'-34

'E5CE'-20

'E5CE'-20

C1 C1 C1

C1

'5CE'-13

'LF'-34

'LF'-34

'LF'-33

'5CE'-5'5CE'-3

'LF'-33

'E5CE'-20

C1 C1

C1

C1

C1

C1

'LF'-35

'LF'-35

'LF'-35

'5CE'-5

'LF'-33

'LF'-33

C2

'LF'-34

'LF'-34

'5CE'-7

5CE-7

'LF'-34C1

C2 C2

PNL-E5CT

a a a

'LF'-34

a

'LF'-33

'ELS5C'-1

'LF'-33

a a a a

'ELS5C'-1

a a a a a a

'LF'-33

a a

'E5CE'-20

'LF'-34

'LF'-35

a a a

'LF'-33

a a a a

'E5CE'-20

a

B1

'ELS5C'-2

'LF'-37

'LF'-37

'LF'-37

'LF'-37

'LF'-37 'LF'-37'LF'-37'LF'-37

'5CE'-13

A1 A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1 A1A1

E1

E1

R

R.1

5 5.1 6 7 8 9 10

SS

TT

'LF'-35 'ELS5C'-1

TO PNL 'LF'

(B5017A)

3/4" C

TO PNL 'ELS5C'/ 'E5CE'

(B5017A)

(2) 3/4" C

'E5C8'-10, 18

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:0

:1

P

M

EL101

FIFTH FLOOR LIGHTING PLAN

10 16MAH JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

0 4 8 16

NORTH

TRUE

Scale: 1/8" = 1'-0"

FIFTH FLOOR LIGHTING PLAN

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

A. ALL LIGHTING CONDUCTORS SHALL BE 2-12

AWG, 1-12 AWG EG IN 3/4" CONDUIT UNLESS

NOTED OTHERWISE:

20-AMP CIRCUITS LESS THAN 150'

SHALL BE MINIMUM 2-12 AWG, 1-12 AWG

EG IN 3/4" C.

20-AMP CIRCUITS 150'-250' SHALL BE

MINIMUM 2-10AWG, 1-10 AWG EG IN

3/4" C.

20-AMP CIRCUITS GREATER THAN 250'

SHALL BE MINIMUM 2-8 AWG, 1-8 AWG

EG IN 3/4" C.

B. ALL UN-SWITCHED EXIT SIGNS, EMERGENCY

NIGHT LIGHTS (EM NL), AND EMERGENCY

LIGHTING UNITS SHALL BE CIRCUITED FROM

LIGHTING CIRCUIT 'LS5C'-1, BUT AHEAD OF ANY

CONTROLS OR SWITCHES.

C. ALL SWITCHED EMERGENCY LIGHTS (EM)

SHALL HAVE BOTH NORMAL AND EMERGENCY

POWER. DURING EMERGENCY CONDITION THE

GENERATOR TRANSFER DEVICE SHALL

DETECT NORMAL POWER VOLTAGE LOSS,

TRANSFER TO EMERGENCY POWER AND

EMERGENCY LIGHT SHALL RETURN TO FULL-

OUTPUT. DURING NORMAL NON-EMERGENCY

CONDITION LIGHT FIXTURES SHALL BE

SWITCHED WITH NORMAL LIGHTING AS

SHOWN. SEE DETAIL 5/E-501 NORMAL POWER

CIRCUIT AS SHOWN ON PLAN. EMERGENCY

POWER CIRCUIT IS ON NEW PANEL 'S1H2'.

D. LOCATION AND QUANTITY OF OCCUPANCY

SENSORS IS APPROXIMATE. CONTRACTOR

SHALL FOLLOW MANUFACTURER'S

RECOMMENDED PLACEMENT AND INSTALL PER

MANUFACTURER'S INSTRUCTION..

E. CONTRACTOR SHALL VERIFY COMPATIBILITY

OF ALL LIGHTING CONTROLS WITH THE LED

DRIVERS TO BE CONTROLLED.

F. COORDINATE ALL TIME DELAY, AUTO DIM,

PRESET DIMMING LEVELS, SENSOR

SENSITIVITY AND CONFIGURATIONS WITH THE

COR.

01 (TYP) PROVIDE SWITCH IN CONJUNCTION

WITH PATIENT EXAM/READING LIGHT.

COORDINATE INTERCONNECTION WITH BED

CONTROLS. COORDINATE WITH

MANUFACTURER AND COR.

02 UNDERCABINET LIGHT (TYPE “H”) WITH

ROUND, FROSTED ACRYLIC LENS. (48”L x

2-5/8”W). CIRCUIT TO LIGHTS IN NURSE AREA.

SEE DETAILS AI431.

03 SEE SHEET GC001 FOR WORK SCOPE

RELATED TO ALTERNATE DEDUCT 1.

Scale: 1/8" = 1'-0"

FIFTH FLOOR LIGHTING PLAN ALTERNATE DEDUCT 1 0 4 8 16

NORTH

TRUE

M

M M

M

M

M M M

M

M

M

M

M

M

M

M M

M

M

M

M

M

E E E E E

EE

E

EE

E

E

E

E E

E E E

E

E

E E E

E

EE

EE

E

E

E

E

E

E

E

E

E

M

E

PATIENT RM

B5008

CARE STATION

B5009

PATIENT RM

B5010

PATIENT RM

B5011

PATIENT RM, BARIATRIC

B5012

LOCKER

B5014

PATIENT RM

B5016

SOILED UTILITY

B5018

STAFF LOUNGE

B5015

CLEAN SUPPLY

B5019

ALCOVE

B5020

PATIENT RM

B5021

PATIENT RM

B5022

PATIENT RM

B5024

PATIENT RM

B5025

PASSAGE

B5041

NOUR

B5026

MEDS

B5027

BATH

B5007A

CORRIDOR

B5040

BATH

B5008A

BATH

B5010A

BATH

B5011A

BATH

B5016A

BATH

B5024A

BATH

B5025A

BATH

B5021A

BATH

B5022A

STAIR

B5050

STAFF TLT

B5014A PATIENT RM, ISOLATION

B5028

BATH

B5028A

ANTE

B5028B

PATIENT RM, ISOLATION

B5029

BATH

B5029A

ANTE

B5029B

PATIENT RM, BARIATRIC

B5007

CARE STATION

B5005

EQUIP

B5004

BATH

B5012A

CARE STATION

B5023

NURSE MGR OFFICE

B5030

EQUIP

B5017

TEAM WORK ROOM

B5031

ELEC

B5017A

OIT

B5003A

5B-TU-35B-TU-4

5B-TU-5

5B-TU-65B-TU-75B-TU-8

5B-TU-10 5B-TU-11 5B-TU-12

5B-TU-13

5B-TU-14

5B-TU-16

5B-TU-17

5B-TU-9

5B-TU-18

5B-TU-19 5B-TU-20

5B-TU-15

5B-TU-21 5B-TU-22

5B-TU-23

5B-TU-24

L L

M M

N N

P P

Q Q

R R

R.1 R.1

5.1

5.1

8 9

14 15

SS

TT

5B-CU-1

5B-EF-X

5B-SS-1

0203 0302 02

5B-TU-EF-1

'LF'-41

'E5CD'-1

'LF'-41 'LF'-41 'LF'-41

'E5CD'-3

'LF'-40

'LF'-40

'LF'-40

'LF'-40

'LF'-42 'LF'-42

'LF'-42

'LF'-42

'E5CD'-4

'E5CD'-2

'E5CE'-13,15,17

'E5CD'-8,10

01'E5CD'-5

(ELS-5C)

(L-F)

(E5CD)

(E5CE)

(EX)

R R

R.1 R.1

5.1

5.1

8 9

SS

TT

JJ

E

M

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:0

:2

P

M

EM101

FIFTH FLOOR MECHANICAL POWER

PLAN

11 16MAH JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

Scale: 1/8" = 1'-0"

FIFTH FLOOR MECHANICAL POWER PLAN

01 POWER CONNECTION FOR MED GAS ALARM

SYSTEM. COORDINATE WITH PLUMBING AND

COR.

02 EQUIPMENT CONNECTION FOR PATIENT BED

LIFT. PROVIDE MOTOR RATED SWITCH.

COORDINATE PLACEMENT WITH COR AND

DEVICE MANUFACTURER.

03 EQUIPMENT CONNECTION FOR BARIATRIC

PATIENT BED LIFT. PROVIDE MOTOR RATED

SWITCH. COORDINATE PLACEMENT WITH COR

AND DEVICE MANUFACTURER.

04 MECHANICAL EQUIPMENT LOCATED AT

LOWER ROOF LEVEL. COORDINATE WITH

MECHANICAL TRADES.

05 PROVIDE 3/4"C FOR CONNECTION OF 5B-CU-1

TO 5B-SS-1. CONTROL/POWER CABLING BY

OTHERS.

06 REFERENCE MECHANICAL CONDUCTOR

SCHEDULE E-602.

08 SEE SHEET GC101 FOR WORK SCOPE

RELATED TO ALTERNATE 3.

A. SEE -E401 FOR ELECTRICAL ROOM AND

CLOSET ENLARGEMENTS.

B. ALL CONDUCTORS SHALL BE 2-12 AWG, 1-12

AWG EG IN 3/4" CONDUIT UNLESS NOTED

OTHERWISE:

20-AMP CIRCUITS LESS THAN 150'

SHALL BE MINIMUM 2-12 AWG, 1-12 AWG

EG IN 3/4" C.

20-AMP CIRCUITS 150'-250' SHALL BE

MINIMUM 2-10AWG, 1-10 AWG EG IN

3/4" C.

20-AMP CIRCUITS GREATER THAN 250'

SHALL BE MINIMUM 2-8 AWG, 1-8 AWG

EG IN 3/4" C.

C. COORDINATE LOCATION AND ELECTRICAL

REQUIREMENTS OF MECHANICAL AND

PLUMBING EQUIPMENT WITH MECHANICAL AND

PLUMBING CONTRACTORS.

D. COORDINATE EQUIPMENT WITH

ARCHITECTURAL EQUIPMENT PLANS AND

SCHEDULES.

E. ELECTRICAL CONTRACTOR SHALL FOLLOW

SITE LOCK-OUT/ TAG-OUT GUIDELINES TO

DEENERGIZE EQUIPMENT.

F. ALL EQUIPMENT CONNECTIONS SHALL HAVE

THEIR SOURCE PANEL AN CIRCUIT NUMBER

INDICATED ON LOCAL MOTOR RATED SWITCH

OR DISCONNECT.

Scale: 1/8" = 1'-0"

FIFTH FLOOR MECHANICAL POWER PLAN ALTERNATE

DEDUCT 1

0 4 8 16

NORTH

TRUE

0 4 8 16

NORTH

TRUE

TO PNL 'LF'

(B5017A

3/4" C

TO PNL 'E5CD'

(B5017A)

E5CD-4

J J

J

AC

GFI

AC

GFI

U

SB

USB

U

SB AC 72

J J

J

AC

GFI

AC

GFI

USB

U

SB

U

SB AC

AC

GFI

AC

GFI

USB

J J

J

U

SB AC

AC

GFI

AC

GFI

AC

GFI

AC

GFI

DEDDEDDED

AC

DED

AC

GFI

DED

AC J

J J

AC

GFI

AC

GFI

USB

U

SB

U

SB AC

PATIENT RM, BARIATRIC

B5012

BATH

B5012A

M

N

P

2 3 4

08PATIENT RM

B5008

BATH

B5008A

M

N

P

10 11

PATIENT RM

B5010

BATH

B5010A

M

N

P

5 5.1 6 7

NOUR

B5026

MEDS

B5027

Q

R

8 9 10

'LF'-26

'E5CE'-12

'LF'-22

'LF'-24

'LF'-29

'LF'-38

'E5CE'-14

'E5CE'-16

B1-PNL-ELS5C

B1-PNL-E5CD

B1-PNL-E5CE

B1-PNL-LF

Q

'LF'-1

OIT

B5003A

PNL-E5CT

M

N

P

'E5CT'-1

'E5CT'-3,5

'E5CT'- 2,4

BIO

B5003

'E5CT'-6,8

PATIENT RM, ISOLATION

B5028

BATH

B5028A

ANTE

B5028B

Q

R

R.1

10 11

05 06

(E5CE-2)

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:0

:5

P

M

E-401

ENLARGED ELECTRICAL PLANS

12 16MAH JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

N

AREA OF WORK

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

Scale: 1/4" = 1'-0"

PATIENT ROOM B5012

Scale: 1/4" = 1'-0"

PATIENT ROOM B5008

Scale: 1/4" = 1'-0"

PATIENT ROOM B5010

Scale: 1/4" = 1'-0"

MEDS B5027 & NOUR B5026 0 2 4 8

NORTH

TRUE

0 2 4 8

NORTH

TRUE

0 2 4 8

NORTH

TRUE

0 2 4 8

NORTH

TRUE

0 2 4 8

NORTH

TRUE

Scale: 1/4" = 1'-0"

ELECTRICAL B5017A

Scale: 1/4" = 1'-0"

OIT B5003A 0 2 4 8

NORTH

TRUE

0 2 4 8

NORTH

TRUE

A. ALL CONDUCTORS SHALL BE 2-12 AWG, 1-12

AWG EG IN 3/4" CONDUIT UNLESS NOTED

OTHERWISE:

20-AMP CIRCUITS LESS THAN 150'

SHALL BE MINIMUM 2-12 AWG, 1-12 AWG

EG IN 3/4" C.

20-AMP CIRCUITS 150'-250' SHALL BE

MINIMUM 2-10AWG, 1-10 AWG EG IN

3/4" C.

20-AMP CIRCUITS GREATER THAN 250'

SHALL BE MINIMUM 2-8 AWG, 1-8 AWG

EG IN 3/4" C.

B. COORDINATE LOCATION AND ELECTRICAL

REQUIREMENTS OF MECHANICAL AND

PLUMBING EQUIPMENT WITH MECHANICAL AND

PLUMBING CONTRACTORS.

C. COORDINATE EQUIPMENT WITH

ARCHITECTURAL EQUIPMENT PLANS AND

SCHEDULES.

D. ELECTRICAL CONTRACTOR SHALL FOLLOW

SITE LOCK-OUT/ TAG-OUT GUIDELINES TO

DEENERGIZE EQUIPMENT.

E. ALL RECEPTACLES SHALL HAVE THEIR

SOURCE PANEL AND CIRCUIT NUMBER

INDICATED ON THEIR FACEPLATE.

01 TYP FOR BARIATRIC PATIENT ROOMS B5007

AND B5012.

02 TYP FOR ISOLATION PATIENT ROOMS B5028

AND B5029.

03 TYP FOR STANDARD PATIENT ROOMS.

04 FEED PANEL 'E5CT' FROM PANEL

'E5CE'-19,21,23. REFERENCE SINGLE LINE

SHEET E-601. LOCATE TVSS ADJACENT TO

PANEL.

05 RECEPTACLE WITH USB CHARGING PORT.

COMBINATION DEVICE WITH

TAMPER-RESISTANT OUTLET (5-15R) WITH

TYPE A AND TYPE C USB CHARGERS.

LEVITON T5632-HGW OR EQUAL.

06 SEE RESPECTIVE FLOOR PLAN. NORMAL

POWER GENERAL SERVICES CIRCUIT GS-1.

07 SEE RESPECTIVE FLOOR PLAN. NORMAL

POWER GENERAL SERVICES CIRCUIT GS-2.

08 SEE RESPECTIVE FLOOR PLAN. ESSENTIAL

POWER (CRITICAL EQUIPMENT) CIRCUIT EC.

09 3-10 AWG, 1-10 AWG N, 1-10 AWG EGC

IN 3/4" C.

10 30A 208V 1 PHASE RECEPTACLE.

COORDINATE TYPE WITH OWNER

EQUIPMENT.

11 STACKED CONTROL CABINETS FOR

PACS/NURSE CALL. COORDINATE LOCATION

IN FIELD.

12 AT PATIENT HEADWALL SYSTEM (SEE AI431)

AND SPECIFICATIONS. CIRCUIT

DESIGNATIONS E1, E3 ARE CONNECTED TO

(GS-2) SEE NOTE 7. CIRCUIT DESIGNATIONS

E2, E4 ARE CONNECTED TO (EC) SEE NOTE 8.

13 RELOCATED PANEL 'LF'. PROVIDE NEW

SURFACE MOUNTED TUB FOR PANEL

INTERIOR.

14 20A 208V 1 PHASE RECEPTACLE.

COORDINATE WITH USP PROVIDED AT BIO

MED RACK. SEE SHEET TK503.

010303

02 12

121212

Scale: 1/4" = 1'-0"

PATIENT ROOM B5028

CEILING

MAIN BEAM RECESSED CAN

LUMINAIRE

CEILING BEAM

GYPSUM BOARD (TYP)

LUMINAIRE

BAR HANGERSRECESSED CAN

LUMINAIRE

CEILING

CROSS BEAM

WIRE TIE OR SCREW

BAR HANGER TO

CROSS BEAM TYP.

CEILING HANGER

WIRE, TYP.

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING

INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.

FIXTURE WHIP FROM

JUNCTION BOX (6' LONG MAX)

LUMINAIRE SUSPENSION

WIRE

CEILING HANGER

WIRE, TYP.

WIRE TIE OR

SCREW BAR

HANGER TO

ARCHITECTURAL

CEILING GRID TYP.

ARCHITECTURAL

CEILING GRID RECESSED CAN

LUMINAIRE

RECESSED CAN

LUMINAIRE

ARCHITECTURAL CEILING GRID

ACOUSTICAL

CEILING TILE

(TYP)

LUMINAIRE

BAR HANGERS

LUMINAIRE SUSPENSION

WIRE

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING

INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.

FIXTURE WHIP FROM

JUNCTION BOX (6' LONG MAX)

CEILING HANGER WIRE

DRYWALL

CEILING CROSS

TEE, TYP.

INTEGRAL GALVANIZED LIPPED

STEEL MOUNTING CHANNEL

HANGER WIRE AND MOUNTING

CHANNEL ATTACHED TO

STRUCTURE

WIRE TIE THROUGH

MOUNTING CHANNEL

& CROSS BEAM, TYP.

CEILING MAIN

BEAM

GYPSUM

BOARD

DRYWALL

CEILING CROSS

TEE, TYP. 1/4" SCREW

JUNCTION BOX

LOCKING

SQUARE

WASHER & NUT

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING

INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING

HARDWARE.

FIXTURE WHIP FROM JUNCTION

BOX (6' LONG MAX.)

CEILING HANGER WIRE

ARCHITECTURAL

CEILING GRID

HANGER WIRE AND MOUNTING

CHANNEL ATTACHED TO

STRUCTURE.

INTEGRAL GALVANIZED LIPPED

STEEL MOUNTING CHANNEL

WIRE TIE THROUGH

MOUNTING CHANNEL

& CROSS BEAM, TYP.

ARCHITECTURAL

CEILING GRID

ACOUSTICAL CEILING

TILE, TYP.

ARCHITECTURAL

CEILING GRID

1/4" SCREW

JUNCTION BOX

LOCKING SQUARE

WASHER & NUT

FIXTURE WHIP FROM JUNCTION

BOX (6' LONG MAX)

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING

INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.

LUMINAIRE MANUFACTURER'S

EARTHQUAKE CLIP, (4) PER

FIXTURE AT CORNERS. ATTACH

WITH SHEET METAL SCREW

FIXTURE WHIP

FROM JUNCTION

BOX

(6FT. LONG MAX.)

LUMINAIR. REFER TO

SCHEDULE

LUMINAIRE. REFER TO

SCHEDULE

DRYWALL BORDER

CEILING CROSS

BEAM

GYPSUM BOARD

CEILING MAIN BEAM

CEILING CROSS BEAM

GYPSUM BOARD

(TYP)

3 TWIST

MINIMUM (TYP)

LUMINAIRE

SUSPENSION WIRES

(#10 MIN)

ATTACHED TO

STRUCTURE

(TYP EA. CORNER)

LUMINAIRE MANUFACTURER'S

EARTHQUAKE CLIP, (4) PER

FIXTURE AT CORNERS. ATTACH

WITH SHEET METAL SCREW

FIXTURE WHIP

FROM JUNCTION

BOX

(6FT. LONG MAX.)

LUMINAIRE. REFER TO

SCHEDULE

ARCHITECTURAL

CEILING GRID

LUMINAIRE. REFER

TO SCHEDULE

ACOUSTICAL CEILING

TILE (TYP)

3 TWIST

MINIMUM (TYP)

LUMINAIRE

SUSPENSION WIRES

(#10 MIN)

ATTACHED TO

STRUCTURE

(TYP EA. CORNER)

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:0

:5

P

M

E-501

ELECTRICAL DETAILS

13 16MAH JDM

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 06/28/2019

BID DOCUMENTS

558-18-15018-048

Scale: N.T.S.

DOWNLIGHT MOUNTING - GYPBOARD CEILING

Scale: N.T.S.

DOWNLIGHT MOUNTING - LAY-IN CEILING

Scale: N.T.S.

EXIT SIGN MOUNTING - GYPBOARD CEILING

Scale: N.T.S.

EXIT SIGN MOUNTING - LAY-IN CEILING

Scale: N.T.S.

LUMINAIRE MOUNTING - GYPBOARD CEILING

Scale: N.T.S.

LUMINAIRE MOUNTING - LAY-IN CEILING

1. WALL ASSEMBLY - THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE

CONSTRUCTED

OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION

DESIGNS

IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:

A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2 HR FIRE RATED ASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16 IN. (406 MM) OC

WITH

NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM)

WIDE BY 1-3/8 IN. (35 MM) DEEP CHANNELS SPACED MAX 24 IN. (610 MM) OC.

B. GYPSUM BOARD* - NOM 1/2 OR 5/8 IN. (13 OR 16 MM) THICK, 4 FT. (122 CM) WIDE WITH SQUARE OR TAPERED EDGES.

THE

GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE

AS

SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .