36C24620R0007-0005001.pdf

PDF Posted

Attached to
Inpatient Privacy Renovate 5B
Solicitation number
36C24620R0007
Issued by

About this file

This presolicitation notice is for an inpatient privacy renovation project at the Durham VA Medical Center in North Carolina. The Department of Veterans Affairs is seeking a contractor to gut and renovate approximately 8,000 square feet of space on the fifth floor into twelve new private patient rooms and ancillary spaces. The estimated construction value is between $1,000,000 to $5,000,000. The solicitation is anticipated to be a total service-disabled veteran owned small business set-aside. The solicitation material will be available on November 7, 2019, with proposals due approximately 45 days later. Questions regarding this announcement must be emailed to the specified point of contact.

36C24620R0007 0005 01-Gen_100_BD.pdf

View the file

Other files

File Type Posted
36C24620R0007-0011001.pdf PDF
36C24620R0007-0011002.pdf PDF
36C24620R0007-0011000.docx DOCX document
36C24620R0007-0010000.docx DOCX document
36C24620R0007-0009000.docx DOCX document
36C24620R0007-0008001.pdf PDF
36C24620R0007-0008000.docx DOCX document
36C24620R0007-0007000.docx DOCX document
36C24620R0007-0006004.pdf PDF
36C24620R0007-0006006.pdf PDF
36C24620R0007-0006000.docx DOCX document
36C24620R0007-0006003.pdf PDF
36C24620R0007-0006005.pdf PDF
36C24620R0007-0006001.pdf PDF
36C24620R0007-0006002.pdf PDF
36C24620R0007-0005000.docx DOCX document
36C24620R0007-0005005.pdf PDF
36C24620R0007-0005004.pdf PDF
36C24620R0007-0005002.pdf PDF
36C24620R0007-0005003.pdf PDF
36C24620R0007-0004000.docx DOCX document
36C24620R0007-0003000.docx DOCX document
36C24620R0007-0003001.pdf PDF
36C24620R0007-0002002.pdf PDF
36C24620R0007-0002001.docx DOCX document
36C24620R0007-0001001.pdf PDF
36C24620R0007-023.pdf PDF
36C24620R0007-022.docx DOCX document
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F U

L T

O N

S T

R E

E T

ERWIN ROAD

A

D

C

B

E

F

MRI

I.C.U.

U N

D E

R C

O N

S T

R U

C T

IO

N

BOOTH

IMPROVE INPATIENT PRIVACY

(RENOVATE 5B)

DURHAM VA MEDICAL

CENTER

508 FULTON STREET

DURHAM, NC 27705

BID DOCUMENTS

VA PROJECT NO. 558-18-150

508 FULTON ST.

VA APPROVAL

MEDICAL CENTER DIRECTOR

MEDICAL CENTER ASSOC. DIRECTOR

CHIEF OF STAFF

ASSOC. DIRECTOR OF PATIENT CARE

CHIEF FES

PROJECT SECTION SUPERVISOR

PROJECT MANAGER

GENERAL UTILITIES FOREMAN

PATIENT CARE FORMAN

GENERAL PROPERTIES FOREMAN

FIRE CHIEF

SUPERVISOR BIO-MED SERVICE

CHIEF LOGISTICS

PATIENT SAFETY MANAGER

SAFETY OFFICER

CIO OFFICER

INFECTION PROVENTION

CONTRACTING OFFICER

A

LA

R

E GI H,NC

S

G O 52644

P E

N

CO

LU IT

E

NG

RG

U O

A

P ,P

R E

G I

S T

E R

E D

A R

C H I T E C T U R

A L

C O

R P

O T

I O

N

N O

R T H C A R O L

I N A

A R

R

EG

IS

TE

RED ARCH

ITEC

T

N O R

T H

CA RO

L

I N A

11389

C

UL

LEN

S . KEEN

C H A R

LOTTE , NORTH

CA

RO

L

IN

A

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS PROJECT

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:5

:2

P

M

G-000

COVER SHEET

1 4RP/CK CK/AB

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 6/28/2019

BID DOCUMENTS

558-18-150

12" = 1'-0"2

VICINITY MAP

DRAWING LIST

# Description

GENERAL

G-000 COVER SHEET

GI001 FIFTH FLOOR PHASING AND ICRA PLAN

GL101 FIFTH FLOOR LIFE SAFETY PLAN

GC101 ALTERNATE SCOPE PLANS

INDUSTRIAL HYGIENE

HA101 ASBESTOS CONTAINING MATERIALS TO BE ABATED

HA102 ASBESTOS ABATEMENT NOTES

ARCHITECTURAL

A-001 PARTITION TYPES AND DETAILS

AD101 FIFTH FLOOR DEMOLITION PLAN

AI101 FIFTH FLOOR PLAN

AI102 FIFTH FLOOR DIMENSION PLAN

AI121 FIFTH FLOOR REFLECTED CEILING PLAN

AI301 ARCHITECTURAL SECTIONS

AI401 ENLARGED FLOOR SLOPE PLANS

AI431 INTERIOR ELEVATIONS

AI432 INTERIOR ELEVATIONS

AI501 INTERIOR DETAILS

AI541 CASEWORK DETAILS

AI601 DOOR SCHEDULE AND DETAILS

IF101 FIFTH FLOOR FINISH PLAN

IF102 FIFTH FLOOR WALL PROTECTION PLAN

IG101 FIFTH FLOOR SIGNAGE PLAN

QH101 FIFTH FLOOR EQUIP PLAN - AREA A

QH102 FIFTH FLOOR EQUIP PLAN - AREA B

FIRE PROTECTION

F-001 FIRE PROTECTION GENERAL INFORMATION

FD101 FIFTH FLOOR FIRE PROTECTION DEMOLITION PLAN

FP101 FIFTH FLOOR FIRE PROTECTION PLAN

PLUMBING

P-001 PLUMBING LEGEND, ABBREVIATIONS, AND GENERAL NOTES

PD101 FOURTH FLOOR PLUMBING DEMOLITION PLAN

PD102 FIFTH FLOOR PLUMBING DEMOLITION PLAN

PD103 FIFTH FLOOR MEDICAL GAS DEMOLITION PLAN

PP101 FIFTH FLOOR WASTE AND VENT PLAN

PP102 FIFTH FLOOR DOMESTIC WATER PLAN

PG101 FIFTH FLOOR MEDICAL GAS PLAN

P-401 ENLARGED PLUMBING PLANS

P-501 PLUMBING DETAILS

PP901 RISERS WASTE AND VENT

PP902 RISERS WASTE AND VENT

PP903 RISERS DOMESTIC WATER

PP904 RISERS DOMESTIC WATER

MECHANICAL

M-001 MECHANICAL GENERAL INFORMATION

MD101 FIFTH FLOOR MECHANICAL DEMOLITION PLAN

MH101 FIFTH FLOOR HVAC PLAN

MH102 FIFTH FLOOR AIR TERMINAL PLAN

MP101 FIFTH FLOOR PIPING PLAN

M-501 MECHANICAL DETAILS

M-502 MECHANICAL DETAILS

M-601 MECHANICAL SCHEDULES

M-602 MECHANICAL SCHEDULES

ELECTRICAL

E-001 ELECTRICAL GENERAL INFORMATION

ED101 FIFTH FLOOR ELECTRICAL DEMOLITION PLAN

EP101 FIFTH FLOOR POWER PLAN

EP102 PARTIAL GROUND FLOOR ELECTRICAL ROUTING PLANS

EP103 PARTIAL FIRST FLOOR ELECTRICAL ROUTING PLANS

EP104 PARTIAL SECOND FLOOR ELECTRICAL ROUTING PLANS

EP105 PARTIAL THIRD FLOOR ELECTRICAL ROUTING PLANS

EP106 PARTIAL FOURTH FLOOR ELECTRICAL ROUTING PLANS

EP107 PARTIAL FIFTH FLOOR ELECTRICAL ROUTING PLANS

EL101 FIFTH FLOOR LIGHTING PLAN

EM101 FIFTH FLOOR MECHANICAL POWER PLAN

E-401 ENLARGED ELECTRICAL PLANS

E-501 ELECTRICAL DETAILS

E-502 ELECTRICAL DETAILS

E-601 ONE-LINE DIAGRAM

E-602 ELECTRICAL SCHEDULES

TECHNOLOGY

TK001 TECHNOLOGY GENERAL INFORMATION

TD101 FIFTH FLOOR TECHNOLOGY DEMOLITION PLAN

TK101 FIFTH FLOOR TECHNOLOGY PLAN

TK102 FIFTH FLOOR SYSTEMS PLAN

TK103 FIFTH FLOOR OVERALL SYSTEMS PLAN

TK104 GROUND FLOOR TECHNOLOGY ROUTING PLAN

TK501 TECHNOLOGY DETAILS

TK502 TECHNOLOGY DETAILS

TK503 TECHNOLOGY DETAILS

FIRE ALARM

FA001 FIRE ALARM GENERAL INFORMATION

FA100 FIFTH FLOOR FIRE ALARM DEMOLITION PLAN

FA101 FIFTH FLOOR FIRE ALARM PLAN

1" = 160'-0"3

CAMPUS MAP

DocuSign Envelope ID: 80B92A2A-987E-4838-852A-3067C97F4F07

6/26/2019

1 3 4 5 7 10 11 12

13 14 15 16

5.1 96 8

L

S

T

N

Q

R

M

P

R.1

E

LE

V A

TO

R

A C

C E

S S

ANTEROOM

LI

M

IT

O

F P

R

IM

A R

Y S

C O

P E

1. PERFORM WORK REQUIRED BY VA INFECTION CONTROL PERSONNEL

REGARDING ICRA FORM. REFER TO VA'S ICRA FORM FOR REQUIREMENTS. ALL ICRA AND

ILSM WORK ITEMS MUST BE COMPLETED PRIOR TO BEGINNING ANY NEW CONSTRUCITON

WORK OR DEMOLITION.

2. VA REQUIRES THAT ALL APPLICABLE PERMITS BE COMPLETED AND APPROVED

PRIOR TO BEGINNING ANY WORK ON STATION. PERMITS INCLUDE: ICRA, ILSM, ABOVE

CEILING, FIRE/SMOKE WALL, UTILITY, FIRE SPRINKLER, FIRE ALARM SYSTEM, MEDICAL

GASES, AND CONFINED SPACE.

3. THIS PROJECT NEEDS AN ENTRY ANTEROOM FOR CLOTHING CHANGES.

PROVIDE STAGING AREA FOR PPE (PERSONAL PROTECTIVE EQUIMENT AND HAZMAT

SUITS) AND TOOL STORAGE. TIGHT SEALS SHALL BE MAINTAINED AT THE FULL PERIMETER

OF WALLS AND WALL PENETRATIONS. ANY DUST SHALL BE IMMEDIATELY CLEANED IF

TRACKED OUTSIDE OF THE CONSTRUCTION BARRIER. UPON COMPLETION OF THE

CONSTRUCTION PHASE, DUST BARRIERS SHALL BE REMOVED CARFULLY TO MINIMIZE

SPREADING OF DUST, AND THE CONTRACTOR SHALL HAVE TEMPORARY DUST

PROTECTION IN PLACE BEFORE REMOVING A CONSTRUCTION BARRIER. LOCATION OF

ANTEROOM CANNOT INTERFERE WITH EGRESS OUTSIDE THE CONSTRUCTION ZONE.

4. INSTALL TEMPORARY EXHAUST SYSTEM, ROUTED THROUGH EXISTING WINDOW

UNITS, TO MAINTAIN NEGATIVE PRESSURE IN CONSTRUCTION AREA. CONTRACTOR TO

DETERMINE NUMBER OF EXHAUST FANS REQUIRED TO MAINTAIN NEGATIVE PRESSURE

INSIDE CONSTRUCTION AREA.

5. PROVIDE STICKY MATS AND BLANKET AT THE CONSTRUCTION ANTEROOM.

CHANGE DAILY OR MORE OFTEN AS NEEDED TO PREVENT THE SPREAD OF DUST AND

DEBRIS INTO ADJACENT CLEAN SPACE.

1 PROVIDE TEMPORARY 2-HOUR RATED SLAB-TO-SLAB BARRIER

CONSISTING OF 3 5/8" METAL STUD FRAMING W/ 2 LAYERS 5/8"

GYP BD ON BOTH SIDES. BARRIER SHALL BE INSPECTED BY

VA ICRA STAFF PRIOR TO START OF CONSTRUCTION IN SPACE.

MAINTAIN NEGATIVE PRESSURE VENTILATION IN THE

CONSTRUCTION SPACE.

2 PROVIDE 90-MIN RATED HOLLOW METAL DOOR W/ CLOSER FOR

ANTEROOM FOR CONSTRUCTION ACCESS.

3 CONSTRUCTION ACCESS ROUTE.

4 USE ISOLATION CART FOR ALL WORK IN THIS AREA.

5 PROVIDE TWO STICKY MATS AT CONSTRUCTION ANTEROOM.

6 ONE ELEVATOR WILL BE AVAILABLE FOR CONTRACTOR USE.

7 PROVIDE TEMPORARY SLAB-TO-SLAB PARTITION CONSISTING

OF 3 5/8" METAL STUD FRAMING W/ 5/8" GYP BD ON BOTH

SIDES. PARTITION SHALL BE INSPECTED BY VA ICRA STAFF

PRIOR TO START OF CONSTRUCTION IN SPACE. MAINTAIN

NEGATIVE PRESSURE VENTILATION IN THE CONSTRUCTION

SPACE.

8 PROVIDE HOLLOW METAL DOOR FOR ANTEROOM FOR

CONSTRUCTION ACCESS.

9 EXISTING PARTITION SERVES AS PART OF CONSTRUCTION

BARRIER. CONTRACTOR TO VERIFY THAT WALL SEALS TO

STRUCTURE AND THAT PENETRATIONS ARE FIRESTOPPED.

CONTRACTOR SHALL PERFORM ANY PATCHING OF WALLS AND

FIRESTOPPING REQUIRED TO MAINTAIN SEPARATION.

10 HATCH INDICATES AREA OF SITE THAT MAY BE AVAILABLE FOR

TRASH CHUTE AND/OR CONSTRUCTION LIFT. CONTRACTOR TO

COORDINATE EXACT LOCATION WITH COR.

PROJECT PHASING

THE PROJECT SHALL CONSIST OF ONE PRIMARY PHASE. THE W ORK OF

THIS PHASE SHALL BE ORGANIZED AS FOLLOWS:

PHASE 1A:

IMPLEMENT ICRA AND ILSM PLAN.

PHASE 1B:

PRIMARY DEMOLITION WORK. REMOVE WALLS, FINISHES,

FIXTURES, AND UTILITIES AS OUTLINED ON CONSTRUCTION

DOCUMENTS.

PHASE 1C:

COORDINATION OF PLUMBING STACKS TO REMAIN. DESIGN

TEAM HAS VERIFIED EXISTING PLUMBING STACK LOCATIONS

WHERE POSSIBLE. STACKS SERVING OTHER FLOORS MUST BE

MAINTAINED OR REROUTED.

PHASE 1D:

NEW CONSTRUCTION WORK.

ICRA NOTES

DUST CONTROL:

1a. THIS PROJECT NEEDS AN ENTRY ANTEROOM FOR CLOTHING

CHANGES. PROVIDE STAGING AREA FOR PPE (PERSONAL PROTECTIVE

EQUIMENT AND HAZMAT SUITS) AND TOOL STORAGE. TIGHT SEALS SHALL

BE MAINTAINED AT THE FULL PERIMETER OF WALLS AND WALL

PENETRATIONS. ANY DUST SHALL BE IMMEDIATELY CLEANED IF TRACKED

OUTSIDE OF THE CONSTRUCTION BARRIER. UPON COMPLETION OF THE

CONSTRUCTION PHASE, DUST BARRIERS SHALL BE REMOVED CARFULLY

TO MINIMIZE SPREADING OF DUST, AND THE CONTRACTOR SHALL HAVE

TEMPORARY DUST PROTECTION IN PLACE BEFORE REMOVING A

CONSTRUCTION BARRIER.

1b. INSTALL TEMPORARY EXHAUST SYSTEM, ROUTED THROUGH

EXISTING WINDOW UNITS, TO MAINTAIN NEGATIVE PRESSURE IN

CONSTRUCTION AREA. CONTRACTOR TO DETERMINE NUMBER OF

EXHAUST FANS REQUIRED TO MAINTAIN NEGATIVE PRESSURE INSIDE

CONSTRUCTION AREA.

1c. PROVIDE STICKY MATS AT THE CONSTRUCTION ANTEROOM.

CHANGE DAILY OR MORE OFTEN AS NEEDED TO PREVENT THE SPREAD

OF DUST AND DEBRIS INTO ADJACENT CLEAN SPACE.

INTERNAL DEMOLITION AND CONSTRUCTION ACTIVITIES:

2a. USE CONSTRUCTION ACCESS ROUTE NOTED ON DRAWINGS OR AS

DETERMINED BY COR.

2b. TRAFFIC CONTROL: DESIGNATEED ENTRY AND EXIT PROCEDURES

SHALL BE DEFINED. EGRESS PATHS SHALL BE FREE OF DEBRIS.

DESIGNATED ELEVATORS SHALL BE USED DURING SCHEDULED TIMES,

AND ONLY AUTHORIZED PERSONNEL SHALL BE ALLOWED TO ENTER THE

CONSTRUCTION ZONE. SIGNAGE SHALL DIRECT PEDESTRIAN TRAFFIC

AW AY FROM THE CONSTRUCTION AREA AND MATERIALS.

2c. CONTRACTOR SHALL USE TWO CARTS TO TRANSFER

CONSTRUCTION MATERIAL IN AND OUT OF THE PROJECT, WITH A CLEAN

CART USED IN THE AREAS OUTSIDE THE CONSTRUCTION AREA.

2d. DEMOLITION DEBRIS: USE OF TRASH CHUTES IS PREFERRED.

HIGH EFFICIENCY PARTICULATE AIR (HEPA) FILTERED NEGATIVE AIR

MACHINES SHALL BE USED WITH CHUTES, AND THE CHUTE OPENING

SHALL BE SEALED W HEN NOT IN USE. FILTERS SHALL BE BAGGED AND

SEALED BEFORE BEING TRANSPORTED OUT OF THE CONSTRUCTION

AREA. ANY DEBRIS THAT CANNOT BE SENT DOWN THE CHUTE SHALL BE

REMOVED IN CARTS WITH TIGHTLY FITTED COVERS, USING DESIGNATED

TRAFFIC ROUTE. EFFORTS SHALL BE MADE TO MINIMIZE USE OF

ELEVATORS WITH AN EMPHASIS ON TRANSPORT DURING THE LOWEST

PERIOD OF HOSPITAL ACTIVITY. DEBRIS SHALL BE REMOVED DAILY AND

AT TIMES SPECIFIED BY THE VAMC. THE CONTRACTOR SHALL NOT HAUL

DEBRIS THROUGH PATIENT CARE AREAS WITHOUT PRIOR APPROVAL OF

THE COR.

VENTILATION AND ENVIRONMENTAL CONTROLS:

3a. AIR SYSTEM FLOW : THE COR W ILL ADVISE THE CONTRACTOR

WHETHER THE SYSTEM USES OUTSIDE OR RE-CIRCULATED AIR. FILTERS

SHALL BE ADDED OR RETURN VENTS COVERED AS NEEDED W ITH FILTER

MATERIAL OR PLASTIC. AIR MUST FLOW FROM CLEAN TO DIRTY AREAS.

3b. NEGATIVE AIR PRESSURE: THE AIR WITHIN THE CONSTRUCTION

AREA SHALL BE NEGATIVE WITH RESPECT TO SURROUNDING AREAS AND

WITH NO DISRUPTION OF AIR SYSTEMS OF ADJACENT AREAS. USE OF

THE NEGATIVE AIR PRESSURE SYSTEM W ITHIN THE ENCLOSURE TO

REMOVE DUST SHALL PASS AIR THROUGH AN INDUSTRIAL GRADE

PORTABLE HEPA FILTER CAPABLE OF FILTRATION RATES OF 300 TO 800

CFM, OR EXHAUST AIR DIRECTOLY TO THE OUTSIDE IF APPROVED BY THE

VAMC. IF EXHAUST SHAL BE TIED INTO A RE-CIRCULATED AIR SYSTEM, A

PRE-FILTER AND HEPA FILTER SHALL BE USED BEFORE EXHAUST TO

PREVENT CONTAMINATION OF THE DUCTS.

3c. ADJACENT AREAS: THE STATUS OF SEALED PENETRATIONS AND

INTACT CEILINGS SHALL BE VERIFIED DAILY.

3d. AIR EXHCANGE RATES AND PRESSURE RELATIONSHIPS: VAMC

AND CONTRACTOR SHALL VERIFY AND MAINTAIN PROPER RATES IN

CRITICAL AREAS NEAR CONSTRUCTION ACTIVITY AND ENSURE AIR IS NOT

BEING RE-CIRCULATED FROM THE CONSTRUCTION AREA WITHOUT

FILTRATION. PROVIDE AIR PRESSURE TESTING THROUGHOUT THE

PROJECT IN THE FREQUENCY AS IDENTIFIED BY THE COR.

CONTAMINATION:

4a. WORKSITE CLOTHING: CONTRACTOR PERSONNEL CLOTHING

SHALL BE FREE OF LOOSE SOIL AND DEBRIS BEFORE LEAVING THE

CONSTRUCTION AREA. IF PROTECTIVE APPAREL IS NOT WORN (E.G.

COVERALLS, FOOTGEAR, AND HEADGEAR), A HEPA FILTERED VACUUM

SHALL BE USED TO REMOVE DUST FROM CLOTHING BEFORE LEAVING THE

CONSTRUCTION BARRIER. IF PROTECTIVE APPAREL IS UTILIZED,

CONTRACTOR SHALL CONSTRUCTION AN ANTEROOM FOR CHANGING AND

STORING EQUIPMENT. ALL EQUIPMENT, TOOLS, MATERIALS, AND CARTS

TRANSPORTED THROUGH OCCUPIED AREAS SHALL BE MADE FREE OF

DUST AND MOISTURE BY VACUUMING AND WET WIPING BEFORE THEIR

REMOVAL FROM TEH CONSTRUCTION ZONE.

4b. POST CONSTRUCTION: DO NOT REMOVE BARRIERS AND KEEP ALL

HVAC ISOLATION UNTIL CONTRACTOR HAS CLEANED CONSTRCTION ZONE,

VA EMS STAFF HAS DONE A TERMINAL CLEANING, AND VA INFECTION

CONTROL HAS INSPECTED AND APPROVED THE CLEANING.

A

LA

R

E GI H,NC

S

G O 52644

P E

N

CO

LU IT

E

NG

RG

U O

A

P ,P

R E

G I

S T

E R

E D

A R

C H I T E C T U R

A L

C O

R P

O T

I O

N

N O

R T H C A R O L

I N A

A R

R

EG

IS

TE

RED ARCH

ITEC

T

N O R

T H

CA RO

L

I N A

11389

C

UL

LEN

S . KEEN

C H A R

LOTTE , NORTH

CA

RO

L

IN

A

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS PROJECT

SHEET NOTES:

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:5

:3

P

M

GI001

FIFTH FLOOR PHASING AND ICRA PLAN

2 4RP/CK CK/AB

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 6/28/2019

BID DOCUMENTS

558-18-150

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

1/8" = 1'-0"1

FIFTH FLOOR PHASING AND ICRA PLAN

0' 8'4' 16'

LIFE SAFETY

1 Hour Fire Rated Barrier

Travel Distance

25'-0"

Exit W idth

Fire Extinguisher Cabinet FEC

Exit Sign

0 1

0"

Egress Width

Actual Occupant Load

Max. Occupant Load

Fire Extinguisher FE

1Key Note

LSTD: Life Safety Suite Travel Distance (50 or 100 ft depending on number of intervening rooms)

EATD: Exit Access Travel Distance (150 ft)

SBTD: Smoke Barrier Travel Distance (200 ft limit)

2 Hour Fire Rated Barrier

1 Hour Smoke Barrier

2 Hour Smoke Barrier

Smoke Partition

Suite Area

1. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL COMPLY WITH

NFPA 101 AND RELATED NFPA CODES.

2. PENETRATIONS SHALL BE FIRE STOPPED WITH FIRE BARRIER PRODUCTS

AS REQUIRED TO MAINTAIN FIRE RATINGS. INSTALL IN ACCORDANCE WITH

UL ASSEMBLIES AND MANUFACTURER'S INSTRUCTIONS FOR THEIR USE.

PRODUCTS MUST BE APPROVED BY COR PRIOR TO INSTALLATION.

3. SUBMIT SHOP DRAWINGS FOR APPROVAL SHOWING PENETRATIONS,

MATERIALS USED FOR FIRE RATING AND UL ASSEMBLY NO.

4. PROVIDE BLOCKING AT PARTITIONS AS REQUIRED FOR MOUNTING OF

FURNISHED AND NON-FURNISHED WALL-MOUNTED ITEMS.

5. VERIFY THAT CARRIERS TO BE USED FOR WALL MOUNTED SINKS AND

LAVATORIES ARE THE TYPE THAT W ILL FIT WITHIN STUD WALLS SHOWN.

CONTACT ARCHITECT IF THERE IS A CONFLICT.

6. PROVIDE SUPPLEMENTAL FRAMING, INSULATION, AND FINISH MATERIALS

AS REQUIRED TO MAINTAIN PARTITION FIRE-RESISTANCE RATING AT

RECESSED ITEMS.

7. CONTRACTOR SHALL ARRANGE AN INSPECTION OF RATED PARTITIONS

WITH THE COR PRIOR TO INSTALLING CEILING.

8. ALL CURRENT APPLICABLE CODES SHALL BE APPLIED TO THIS PROJECT,

INCLUDING:

a. 2018 NFPA 101

b. 2018 NFPA 99

c. 2016 NFPA 13

d. 2016 NFPA 72

1 3 4 5 7 10 11 12

13 14 15 16

5.1 96 8

L

S

T

N

Q

R

M

P

R.1

223 SF

PATIENT RM

B5008

302 SF

CARE

STATION

B5009

218 SF

PATIENT RM

B5010

223 SF

PATIENT RM

B5011

277 SF

PATIENT RM,

BARIATRIC

B5012

62 SF

LOCKER

B5014

189 SF

PATIENT RM

B5016

94 SF

SOILED

UTILITY

B5018

124 SF

CLEAN

SUPPLY

B5019

58 SF

ALCOVE

B5020

203 SF

PATIENT RM

B5021

193 SF

PATIENT RM

B5022

194 SF

PATIENT RM

B5024

196 SF

PATIENT RM

B5025

155 SF

PASSAGE

B5041

57 SF

NOUR

B5026 117 SF

MEDS

B5027

85 SF

BATH

B5007A

1620 SF

CORRIDOR

B5040

49 SF

BATH

B5008A

49 SF

BATH

B5010A49 SF

BATH

B5011A

49 SF

BATH

B5016A

50 SF

BATH

B5024A

50 SF

BATH

B5025A

49 SF

BATH

B5021A

50 SF

BATH

B5022A

147 SF

STAIR

B5050

51 SF

STAFF TLT

B5014A 217 SF

PATIENT RM,

ISOLATION

B5028

47 SF

BATH

B5028A

42 SF

ANTE

B5028B

212 SF

PATIENT RM,

ISOLATION

B5029

52 SF

BATH

B5029A

41 SF

ANTE

B5029B

274 SF

PATIENT RM,

BARIATRIC

B5007

54 SF

CARE

STATION

B5005

120 SF

EQUIP

B5004

69 SF

BATH

B5012A

63 SF

CARE

STATION

B5013

46 SF

CARE

STATION

B5023

121 SF

NURSE MGR

OFFICE

B5030

123 SF

EQUIP

B5017

239 SF

TEAM WORK

ROOM

B5031124 SF

STAFF

LOUNGE

B5015

46 SF

OIT

B5003A

27 SF

ELEC

B5017A

SUITE S-5C

775 SF

7 OCCUPANTS

S U

IT

E

T R

A V

E L:

1'

-1 1"

TR

A

V E

L D

IS

TA

N C

E : 1

'-3

TRAVEL DISTANCE: 181'-0"

425 36

85"

SMOKE COMPARTMENT 5-01

FULLY-SPRINKLERED

8,569 SQ.FT.

72 OCCUPANTS

SMOKE COMPARTMENT 5-02

FULLY-SPRINKLERED

7,932 SQ.FT.LI

M

IT

O F

P R

IM

A

R Y

S C

O P

E

TRAVEL DISTANCE: 149'-0"

A

LA

R

E GI H,NC

S

G O 52644

P E

N

CO

LU IT

E

NG

RG

U O

A

P ,P

R E

G I

S T

E R

E D

A R

C H I T E C T U R

A L

C O

R P

O T

I O

N

N O

R T H C A R O L

I N A

A R

R

EG

IS

TE

RED ARCH

ITEC

T

N O R

T H

CA RO

L

I N A

11389

C

UL

LEN

S . KEEN

C H A R

LOTTE , NORTH

CA

RO

L

IN

A

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS PROJECT

SHEET NOTES:

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:5

:3

P

M

GL101

FIFTH FLOOR LIFE SAFETY PLAN

3 4RP/CK CK/AB

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 6/28/2019

BID DOCUMENTS

558-18-150

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

1/8" = 1'-0"1

FIFTH FLOOR LIFE SAFETY PLAN

0' 8'4' 16'

1 3 4 5 7 10 11 12

13 14 15 16

5.1 96 8

L

S

T

N

Q

R

M

P

R.1

ALTERNATE NO. 1: REMOVE ROOMS B5021, B5021A,B5022, B5022A, B5023, B5024, B5024A,

B5025, B5025A, AND B5041 FROM NEW WORK. ALL DEMOLITION FOR THIS AREA SHOULD

BE IMPLEMENTED AS DESIGNED, LEAVING THE AREA AS UNFINISHED SPACE. STUB

MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS INTO THE AREA FOR FUTURE

CONNECTIONS. MECHANICAL SYSTEMS SHALL PROVIDE AIRFLOW INTO THE AREA FOR

GENERAL CONDITIONING OF THE SPACE. FIRE PROTECTION (SPRINKLER SYSTEM) MUST

BE INSTALLED TO PROVIDE COVERAGE THROUGHOUT UNFINISHED SPACE.

1 ALTERNATE NO. 1

DOOR TAG

ROOM TAG

1 REVISION TAG

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

KEYNOTE TAG

SECTION TAG

WALL TAG

A101

SIM

1 DETAIL TAG

INTERIOR ELEVATION TAG

REFERENCE

CARD READER

G3.0

A101 1

EXISTING WALL

DEMOLISHED

WALL

NEW WALL

EXISTING DOOR

DEMOLISHED

DOOR

NEW DOOR

A101

CR

Room name

PUSH PLATE DOOR ACTUATORPP

2'x4' Acoustical Tile

REFLECTED CEILING PLAN

LEGEND

Access Panel

Lay-in Light

EXP

Indirect Lay-in Light

2'x2' Acoustical Tile

Gypsum Board Ceiling

Recessed Downlight

Wall Mounted Light

Exit Sign

Strip Light

Supply

Return

Exhaust Air Grill

Elevation Marker

Under Cabinet Light

Recessed Heat Lamp

Exposed to Structure

Cubicle Curtain Track

Lift Track

Ceiling Mounted Equipment

8'-0" Spot Elevation Tag

9'-0"

Sprinkler Head

A

LA

R

E GI H,NC

S

G O 52644

P E

N

CO

LU IT

E

NG

RG

U O

A

P ,P

R E

G I

S T

E R

E D

A R

C H I T E C T U R

A L

C O

R P

O T

I O

N

N O

R T H C A R O L

I N A

A R

R

EG

IS

TE

RED ARCH

ITEC

T

N O R

T H

CA RO

L

I N A

11389

C

UL

LEN

S . KEEN

C H A R

LOTTE , NORTH

CA

RO

L

IN

A

# SHEET KEY NOTES:

Revisions: Date

Drawing Title

Approved ANDREKA WATLINGTON

PROJECT ENGINEER

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS PROJECT

SHEET NOTES:

E

D C

B A

2 3 4 5 6 7

E D

C B

A

1 2 3 4 5 6 7

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

/2

/2

:5

:3

P

M

GC101

ALTERNATE SCOPE PLANS

4 4RP/CK CK/AB

IMPROVE INPATIENT

PRIVACY (RENOVATE 5B)

DURHAM VA MEDICAL CENTER

508 FULTON STREET

DURHAM, NC 27705 6/28/2019

BID DOCUMENTS

558-18-150

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

1/8" = 1'-0"1

FIFTH FLOOR ALTERNATE SCOPE PLAN - ALTERNATE NO. 1

0' 8'4' 16'

Sheets
G-000 - COVER SHEET
GI001 - FIFTH FLOOR PHASING AND ICRA PLAN
GL101 - FIFTH FLOOR LIFE SAFETY PLAN
GC101 - ALTERNATE SCOPE PLANS
2019-06-27T06:04:36-0700
Digitally verifiable PDF exported from www.docusign.com