36C24619R0051-004.pdf
PDF 7 MB Posted
- Attached to
- Upgrade Roofs and Tuckpoints (VA-19-00015851)
- Solicitation number
- 36C24619R0051
About this file
36C24619R0051 658-16-101 FINAL DRAWINGS.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24619R0051-0005001.pdf | ||
| 36C24619R0051-0005000.docx | DOCX document | |
| 36C24619R0051-0004001.txt | TXT text file | |
| 36C24619R0051-0004000.docx | DOCX document | |
| 36C24619R0051-0003000.docx | DOCX document | |
| 36C24619R0051-0003001.pdf | ||
| 36C24619R0051-0002000.docx | DOCX document | |
| 36C24619R0051-0001001.pdf | ||
| 36C24619R0051-0001000.docx | DOCX document | |
| 36C24619R0051-001.xlsx | XLSX spreadsheet | |
| 36C24619R0051-003.pdf | ||
| 36C24619R0051-002.pdf | ||
| 36C24619R0051-000.docx | DOCX document | |
| 36C24619R0051_2.docx | DOCX document |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT SITE LOCATION
SALEM VA MEDICAL CENTER, SALEM, VA.
NTS
1 2
TLRWCB
GI001
COVER SHEET: DRAWING INDEX, MAPS,
GENERAL NOTES
SALEM VETERANS AFFAIRS MEDICAL CENTER
FOR
1970 ROANOKE BOULEVARD SALEM, VA 24153PROJECT # 658-16-101
REPLACE ROOF AND TUCKPOINT
(BUILDING 5)
INDEX OF DRAWINGS
DRAWING TITLESHEET # DWG.#
GENERAL NOTES
Approved: Associate Director
Approved: Chief of Staff
Approved: Service Chief t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e e f o o t o n e i n c h e f o o t t h r e e q u a r t e r s i n c e f o o t o n e h a l f i n c e f o o t t h r e e e i g h t s i n c e f o o t o n e q u a r t e r i n c e f o o t o n e e i g h t i n c e f o o t
DRAWING NO.
Dwg. Of
Project No.
Date
DrawnChecked
Location
Building Number
Project Title
Approved: Medical Center Director
Approved: Chief of Facility Management Svc.
Drawing Title
Date Revisions
Approved: Infection Control Officer
Approved: Safety Manager
Approved: GEMS Coordinator
Approved: Energy Engineer
658-16-101
22 OCT 2018
BUILDING 5
VA MEDICAL CENTER, SALEM, VA 24153
REPLACE ROOF AND TUCKPOINT (BUILDING 5)
102 3rd Ave., NE
Hickory, NC 28601
828.315.9962 www.atriaxgroup.com
2105 Water Ridge Pkwy #450
Charlotte, NC 28217
704.535.6374 www.wmba.net
FINAL CONSTRUCTION DOCUMENTS
Quality Consulting
Engineers, PLLC
6277-600 Carolina Commons Drive, #350 Indian Land SC 29707
803.207.5450 djones@qualityconsultingengineers.com
4191RE
G
IS
TERED ARCHITECT
NORT H CA ROL I N
AC
H
A R L OT T E , N
. C
C
HA
RL
ES W I LL IAM BEV
IN
S
10/22/2018
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 2A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Diamond
AutoCAD SHX Text Baseball
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text '_zoom _w
AutoCAD SHX Text
BUILDING 143
AutoCAD SHX Text
TO BUILDINGS 146, 144 & 12
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text
KEY PLAN
AutoCAD SHX Text
NTS
AutoCAD SHX Text GENERAL: : GI001 1 of 2 COVER SHEET: DRAWINGS INDEX, MAPS, GENERAL NOTES 1 of 2 COVER SHEET: DRAWINGS INDEX, MAPS, GENERAL NOTES COVER SHEET: DRAWINGS INDEX, MAPS, GENERAL NOTES GI002 2 of 2 ARCHITECTURAL ABBREVIATIONS AND SYMBOLS 002 2 of 2 ARCHITECTURAL ABBREVIATIONS AND SYMBOLS 2 of 2 ARCHITECTURAL ABBREVIATIONS AND SYMBOLS ARCHITECTURAL ABBREVIATIONS AND SYMBOLS ARCHITECTURAL: AD101 1 of 12 DEMOLITION PLANS 1 of 12 DEMOLITION PLANS DEMOLITION PLANS AD201 2 of 12 DEMOLITION ELEVATIONS 2 of 12 DEMOLITION ELEVATIONS DEMOLITION ELEVATIONS AE100 3 of 12 EXIT PROTECTION PLAN 3 of 12 EXIT PROTECTION PLAN EXIT PROTECTION PLAN AE101 4 of 12 NEW ATTIC AND ROOF PLANS 4 of 12 NEW ATTIC AND ROOF PLANS NEW ATTIC AND ROOF PLANS AE101A 5 of 12 SNOW GUARD LOCATIONS ROOF PLAN 5 of 12 SNOW GUARD LOCATIONS ROOF PLAN SNOW GUARD LOCATIONS ROOF PLAN AE201 6 of 12 EXTERIOR ELEVATIONS 6 of 12 EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS AE301 7 of 12 ROOFING DETAILS 7 of 12 ROOFING DETAILS ROOFING DETAILS AE302 8 of 12 ROOFING DETAILS 8 of 12 ROOFING DETAILS ROOFING DETAILS AE303 9 of 12 ROOFING DETAILS 9 of 12 ROOFING DETAILS ROOFING DETAILS AE304 10 of 12 ROOFING DETAILS 10 of 12 ROOFING DETAILS ROOFING DETAILS AE305 11 of 12 ROOFING DETAILS 11 of 12 ROOFING DETAILS ROOFING DETAILS AE306 12 of 12 ROOFING DETAILS - FLAT ROOF 12 of 12 ROOFING DETAILS - FLAT ROOF ROOFING DETAILS - FLAT ROOF ELECTRICAL: E-101 1 OF 3 ELECTRICAL - SITE PLAN - LPS 1 OF 3 ELECTRICAL - SITE PLAN - LPS ELECTRICAL - SITE PLAN - LPS E-401 2 OF 3 ELECTRICAL - ROOF PLAN - LPS 2 OF 3 ELECTRICAL - ROOF PLAN - LPS ELECTRICAL - ROOF PLAN - LPS E-801 3 OF 3 ELECTRICAL - LPS DETAILS 3 OF 3 ELECTRICAL - LPS DETAILS ELECTRICAL - LPS DETAILS TOTAL: 1717
AutoCAD SHX Text CONSTRUCTION 1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE PROTECTION FOR THE PERSONS AND PROPERTY, EITHER ON OR ADJACENT TO THE IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE PROTECTION FOR THE PERSONS AND PROPERTY, EITHER ON OR ADJACENT TO THE PROJECT AND SHALL PROTECT SAME AGAINST INJURY, DAMAGE OR LOSS. 2. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING 8' HIGH FENCING (CHAIN LINK AND ABLE TO BE LOCKED) IN AREAS WHERE WORK IS THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING 8' HIGH FENCING (CHAIN LINK AND ABLE TO BE LOCKED) IN AREAS WHERE WORK IS BEING PERFORMED INCLUDING LAY DOWN AND SET-UP AREAS. 3. THE CONTRACTOR SHALL PROVIDE A SPOTTER / QUALIFIED SAFETY PERSON ON THE GROUND IN ALL AREAS WHERE WORK IS BEING THE CONTRACTOR SHALL PROVIDE A SPOTTER / QUALIFIED SAFETY PERSON ON THE GROUND IN ALL AREAS WHERE WORK IS BEING PERFORMED. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY REGULATIONS, PROGRAMS, AND PRECAUTIONS RELATED TO ALL WORK ON THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY REGULATIONS, PROGRAMS, AND PRECAUTIONS RELATED TO ALL WORK ON THIS PROJECT. SEE THE PROJECT SPECIFICATIONS. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION AND ERECTION OF MATERIALS IN ACCORDANCE THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION AND ERECTION OF MATERIALS IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS. 6. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO ORDERING MATERIALS OR PROCEEDING WITH NEW WORK IN AREAS CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO ORDERING MATERIALS OR PROCEEDING WITH NEW WORK IN AREAS AFFECTED BY EXISTING CONDITIONS. THE C.O. (CONTRACTING OFFICER) AND C.O.R. (CONTRACTING OFFICER'S REPRESENTATIVE) SHALL BE AND C.O.R. (CONTRACTING OFFICER'S REPRESENTATIVE) SHALL BE C.O.R. (CONTRACTING OFFICER'S REPRESENTATIVE) SHALL BE NOTIFIED IN WRITING OF CONFLICTS BETWEEN EXISTING AND PROPOSED NEW CONSTRUCTION. 7. THE CONTRACTOR IS RESPONSIBLE FOR LIMITING THE AMOUNT OF CONSTRUCTION LOAD IMPOSED ON NEW AND/OR EXISTING STRUCTURES. THE CONTRACTOR IS RESPONSIBLE FOR LIMITING THE AMOUNT OF CONSTRUCTION LOAD IMPOSED ON NEW AND/OR EXISTING STRUCTURES. SUCH LOADS SHALL NOT EXCEED THE CAPACITY OF THE STRUCTURE AT ANY TIME. DRAWINGS & COORDINATION 1. DIMENSIONS SHOWN ON PLAN ARE TAKEN FROM ORIGINAL DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR VERIFYING AND COORDINATING DIMENSIONS SHOWN ON PLAN ARE TAKEN FROM ORIGINAL DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR VERIFYING AND COORDINATING CONTRACTOR IS RESPONSIBLE FOR VERIFYING AND COORDINATING ALL DIMENSIONS SHOWN ON CONTRACT DOCUMENTS. 2. ANYTHING WHICH, IN THE OPINION OF THE CONTRACTOR, APPEARS TO BE DEFICIENCIES, OMISSIONS, CONTRADICTIONS OR AMBIGUITIES IN ANYTHING WHICH, IN THE OPINION OF THE CONTRACTOR, APPEARS TO BE DEFICIENCIES, OMISSIONS, CONTRADICTIONS OR AMBIGUITIES IN THE PLANS OR SPECIFICATIONS, SHALL BE BROUGHT TO THE ATTENTION OF THE C.O.R.. CORRECTIONS OR WRITTEN INTERPRETATIONS SHALL BE ISSUED BEFORE CONSTRUCTION OF THE AFFECTED WORK MAY PROCEED. 3. DETAILS ARE MARKED AT SPECIFIC LOCATIONS WHERE THEY APPLY, BUT ALSO INDICATE GENERAL CONSTRUCTION REQUIREMENTS FOR DETAILS ARE MARKED AT SPECIFIC LOCATIONS WHERE THEY APPLY, BUT ALSO INDICATE GENERAL CONSTRUCTION REQUIREMENTS FOR OTHER LOCATIONS WITH SIMILAR CONDITIONS. 4. DETAILS NOTED AS "TYPICAL" MAY NOT BE REFERENCED ON THE DRAWINGS. TYPICAL DETAILS APPLY AT ALL LOCATIONS WHERE THE TYPE DETAILS NOTED AS "TYPICAL" MAY NOT BE REFERENCED ON THE DRAWINGS. TYPICAL DETAILS APPLY AT ALL LOCATIONS WHERE THE TYPE OF CONSTRUCTION SHOWN IN THE TYPICAL DETAILS OCCURS.
AutoCAD SHX Text Affairs
AutoCAD SHX Text Veterans
2 2
TLRWCB
GI002
ARCHITECTURAL ABBREVIATIONS
AND SYMBOLS
Approved: Associate Director
Approved: Chief of Staff
Approved: Service Chief t h r e e i n c h e e f o o t o n e a n d o n e h a l f i n c h e e f o o t o n e i n c e f o o t t h r e e q u a r t e r s i n c e f o o t o n e h a l f i n c e f o o t t h r e e e i g h t s i n c e f o o t o n e q u a r t e r i n c e f o o t o n e e i g h t i n c e f o o t
DRAWING NO.
Dwg. Of
Project No.
Date
DrawnChecked
Location
Building Number
Project Title
Approved: Medical Center Director
Approved: Chief of Facility Management Svc.
Drawing Title
Date Revisions
Approved: Infection Control Officer
Approved: Safety Manager
Approved: GEMS Coordinator
Approved: Energy Engineer
658-16-101
22 OCT 2018
BUILDING 5
VA MEDICAL CENTER, SALEM, VA 24153
REPLACE ROOF AND TUCKPOINT (BUILDING 5)
102 3rd Ave., NE
Hickory, NC 28601
828.315.9962 www.atriaxgroup.com
2105 Water Ridge Pkwy #450
Charlotte, NC 28217
704.535.6374 www.wmba.net
FINAL CONSTRUCTION DOCUMENTS
Quality Consulting
Engineers, PLLC
6277-600 Carolina Commons Drive, #350 Indian Land SC 29707
803.207.5450 djones@qualityconsultingengineers.com
4191RE
G
IS
TERED ARCHITECT
NORT H CA ROL I N
AC
H
A R L OT T E , N
. C
C
HA
RL
ES W I LL IAM BEV
IN
S
10/22/2018
AutoCAD SHX Text @ AT (THE RATE OF) AT (THE RATE OF) & AND AND " INCH; DITTO (WHICH MEANS "SAME AS ABOVE") INCH; DITTO (WHICH MEANS "SAME AS ABOVE") # NUMBER; POUND NUMBER; POUND DIAMETER; ROUND; PHASE AB ANCHOR BOLT ANCHOR BOLT ABV ABOVE ABOVE ACC ACCESS ACCESS ACI AMERICAN CONCRETE INSTITUTE AMERICAN CONCRETE INSTITUTE AFF ABOVE FINISHED FLOOR ABOVE FINISHED FLOOR ADDL ADDITIONAL ADDITIONAL ADH ADHESIVE ADHESIVE AGGR AGGREGATE AGGREGATE AIA AMERICAN INSTITUTE OF ARCHITECTS AMERICAN INSTITUTE OF ARCHITECTS AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION AMERICAN INSTITUTE OF STEEL CONSTRUCTION ALUM ALUMINUM ALUMINUM ALT ALTERNATE ALTERNATE ANCH ANCHOR ANCHOR ANSI AMERICAN NATIONAL STANDARDS INSTITUTE AMERICAN NATIONAL STANDARDS INSTITUTE AMT AMOUNT AMOUNT APPROX APPROXIMATE APPROXIMATE APRVD APPROVED APPROVED ARCH ARCHITECTURAL ARCHITECTURAL ASPH ASPHALT ASPHALT ASSOC ASSOCIATION ASSOCIATION ASSY ASSEMBLY ASSEMBLY ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS AMERICAN SOCIETY FOR TESTING AND MATERIALS AVG AVERAGE AVERAGE AWS AMERICAN WELDING SOCIETY AMERICAN WELDING SOCIETY BAL BALANCE; BALLAST BALANCE; BALLAST BEL BELOW BELOW BET BETWEEN BETWEEN BIT BITUMINOUS BITUMINOUS BLDG BUILDING BUILDING BLK(G) BLOCK(ING) BLOCK(ING) BM BEAM BEAM BOT BOTTOM BOTTOM BPL BEARING PLATE;BASE PLATE BEARING PLATE;BASE PLATE BRG BEARING BEARING BUR BUILT UP ROOF BUILT UP ROOF CB CHASE BOX CHASE BOX CFL COUNTERFLASHING COUNTERFLASHING CIR CIRCLE; CIRCULAR CIRCLE; CIRCULAR CJ CONSTRUCTION JOINT CONSTRUCTION JOINT CL CENTERLINE; CLEARANCE CENTERLINE; CLEARANCE CLG CEILING CEILING CLR CLEAR CLEAR CMU CONCRETE MASONRY UNIT CONCRETE MASONRY UNIT COL COLUMN COLUMN COORD COORDINATE COORDINATE CONC CONCRETE CONCRETE CONN CONNECTION CONNECTION CONST CONSTRUCTION CONSTRUCTION CONT CONTINUOUS CONTINUOUS CTD COATED COATED CTR CENTER CENTER CU. IN CUBIC INCH CUBIC INCH CU. FT CUBIC FOOT CUBIC FOOT CU. YD CUBIC YARD CUBIC YARD DBL DOUBLE DOUBLE DCJ DOWELED CONTROL JOINT DOWELED CONTROL JOINT DEG DEGREE DEGREE DEMO DEMOLITION DEMOLITION DEPT DEPARTMENT DEPARTMENT DET DETAIL DETAIL DIA DIAMETER DIAMETER DIAG DIAGONAL DIAGONAL DIM DIMENSION DIMENSION DL DEAD LOAD DEAD LOAD DN DOWN DOWN DO DITTO; DOOR OPENING DITTO; DOOR OPENING DR DRAIN; DOOR DRAIN; DOOR DS DOWN SPOUT DOWN SPOUT DUP DUPLICATE DUPLICATE DWG(S) DRAWING(S) DRAWING(S) DWL DOWEL DOWEL E EAST EAST EA EACH EACH EDS EXISTING DOWNSPOUT EXISTING DOWNSPOUT EF EACH FACE EACH FACE EIFS EXTERIOR INSULATION AND FINISH SYSTEMS EXTERIOR INSULATION AND FINISH SYSTEMS ELEC ELECTRIC ELECTRIC ELEV ELEVATION; ELEVATOR ELEVATION; ELEVATOR ENTR ENTRANCE ENTRANCE ENGR ENGINEER ENGINEER EPDM ETHYLENE PROPYLENE DIENE MONOMER ETHYLENE PROPYLENE DIENE MONOMER EQ EQUAL EQUAL EQUIP EQUIPMENT EQUIPMENT ES EACH SIDE EACH SIDE EST ESTIMATE ESTIMATE EVAP EVAPORATOR EVAPORATOR EW EACH WAY EACH WAY EXCAV EXCAVATE EXCAVATE EXIST EXISTING EXISTING EXPN EXPANSION EXPANSION EJ EXPANSION JOINT EXPANSION JOINT EXT EXTERIOR EXTERIOR FAB FABRICATE FABRICATE FAST FASTENER; FASTEN FASTENER; FASTEN FD FLOOR DRAIN FLOOR DRAIN FDN FOUNDATION FOUNDATION FF FINISHED FACE; FINISHED FLOOR FINISHED FACE; FINISHED FLOOR FFL FINISHED FLOOR LINE FINISHED FLOOR LINE FIN FINISH FINISH FL FLOOR FLOOR FLG FLASHING; FLOORING; FLANGE FLASHING; FLOORING; FLANGE FM FACTORY MUTUAL FACTORY MUTUAL FT FOOT; FEET FOOT; FEET FTG FOOTING FOOTING FRM FRAME FRAME FURR FURRING FURRING GA GAGE; GAUGE GAGE; GAUGE GAL GALLON GALLON GALV GALVANIZED GALVANIZED GC GENERAL CONTRACTOR GENERAL CONTRACTOR GEN GENERAL; GENERATOR GENERAL; GENERATOR GR GIRDER GIRDER GL GLASS GLASS GRAN GRANULAR GRANULAR GR BM GRADE BEAM GRADE BEAM GWB GYPSUM WALL BOARD GYPSUM WALL BOARD GYP GYPSUM GYPSUM HB HOSE BIB HOSE BIB HD HEAD; HEAVY DUTY HEAD; HEAVY DUTY HDG HOT DIPPED GALVANIZED HOT DIPPED GALVANIZED HEX HD HEXAGONAL HEAD HEXAGONAL HEAD HM HOLLOW METAL HOLLOW METAL HORIZ HORIZONTAL HORIZONTAL HS HIGH STRENGTH HIGH STRENGTH HT HEIGHT HEIGHT HVAC HEATING, VENTILATING AND AIR CONDITIONING HEATING, VENTILATING AND AIR CONDITIONING IBC INTERNATIONAL BUILDING CODE INTERNATIONAL BUILDING CODE ID INSIDE DIAMETER INSIDE DIAMETER IF INSIDE FACE INSIDE FACE ILLUS ILLUSTRATE ILLUSTRATE IN INCH; INCHES INCH; INCHES INCL INCLUDE; INCLINE INCLUDE; INCLINE INFO INFORMATION INFORMATION INSUL INSULATION INSULATION INT INTERIOR; INTERSECTION INTERIOR; INTERSECTION INV INVERT INVERT ISO ISOMETRIC ISOMETRIC JST JOIST JOIST JT JOINT JOINT K KIP (1,000 LBS.) KIP (1,000 LBS.) K/FT KIPS PER FOOT KIPS PER FOOT KO KNOCK OUT KNOCK OUT L ANGLE; LEFT; LENGTH; LINE; LONG ANGLE; LEFT; LENGTH; LINE; LONG LAD LADDER LADDER LAM LAMINATE LAMINATE LB POUND POUND LG LONG LONG LIC LICENSE LICENSE LIN LINEAR LINEAR LNTL LINTEL LINTEL LL LIVE LOAD LIVE LOAD LOC (S) LOCATE; LOCATIONS LOCATE; LOCATIONS LT LIGHT LIGHT LT WT LIGHT WEIGHT LIGHT WEIGHT MAINT MAINTENANCE MAINTENANCE MAN MANUAL MANUAL MANUF MANUFACTURER MANUFACTURER MAX MAXIMUM MAXIMUM MECH MECHANICAL MECHANICAL MEMB MEMBRANE MEMBRANE MET METAL METAL MIN MINIMUM MINIMUM MISC MISCELLANEOUS MISCELLANEOUS MK MARK MARK MMB MEMBRANE MEMBRANE MONO MONOLITHIC MONOLITHIC MTD MOUNTED MOUNTED MTL METAL; MATERIAL METAL; MATERIAL MULT MULTIPLE MULTIPLE N NORTH NORTH N/A NOT APPLICABLE NOT APPLICABLE NDS NEW DOWNSPOUT NEW DOWNSPOUT NF NEAR FACE NEAR FACE NIC NOT IN CONTRACT NOT IN CONTRACT NO NUMBER NUMBER NOM NOMINAL NOMINAL NTS NOT TO SCALE NOT TO SCALE O/C ON CENTER ON CENTER OD OVERFLOW DRAIN OVERFLOW DRAIN OH OPPOSITE HAND OPPOSITE HAND OPNG OPENING OPENING OPP OPPOSITE OPPOSITE ORIG ORIGINAL ORIGINAL OVFL OVERFLOW OVERFLOW OSC OVERFLOW SCUPPER OVERFLOW SCUPPER OSHA OCCUPATIONAL SAFETY AND HEALTH ORGANIZATION OCCUPATIONAL SAFETY AND HEALTH ORGANIZATION OZ OUNCE OUNCE P PITCH PITCH PAR PARALLEL PARALLEL PSC PRESTRESSED CONCRETE PRESTRESSED CONCRETE PTC POST-TENSIONED CONCRETE POST-TENSIONED CONCRETE PEN PENETRATION PENETRATION PERM PERMANENT PERMANENT PERP PERPENDICULAR PERPENDICULAR PL PLATE PLATE PLWD PLYWOOD PLYWOOD PP PITCH POCKET PITCH POCKET PRCST PRECAST PRECAST PREFAB PREFABRICATION PREFABRICATION PROJ PROJECTION PROJECTION PSF POUNDS PER SQUARE FOOT POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH PT PRESSURE TREATED PRESSURE TREATED PTI POST-TENSIONING INSTITUTE POST-TENSIONING INSTITUTE PV PIPE VENT PIPE VENT PVC POLYVINYL CHLORIDE POLYVINYL CHLORIDE QTR QUARTER QUARTER QTY QUANTITY QUANTITY QUAL QUALITY QUALITY R RISER; RADIUS; RESISTANCE RISER; RADIUS; RESISTANCE RAD RADIUS RADIUS RD ROOF DRAIN ROOF DRAIN REBAR REINFORCING BAR REINFORCING BAR REF REFERENCE REFERENCE REG REGULAR REGULAR REINF REINFORCE(D); REINFORCING REINFORCE(D); REINFORCING REM REMAINING; REMAINDER; REMOVE REMAINING; REMAINDER; REMOVE REQD REQUIRED REQUIRED REV REVISED REVISED RF (G) ROOF (ING) ROOF (ING) RGH ROUGH ROUGH RM ROOM ROOM RO ROUGH OPENING ROUGH OPENING S SOUTH SOUTH SCUP SCUPPER SCUPPER SCHED SCHEDULE SCHEDULE SD SECONDARY DRAIN SECONDARY DRAIN SECT SECTION SECTION SF SQUARE FOOT SQUARE FOOT SHT SHEET SHEET SHTHG SHEATHING SHEATHING SIM SIMILAR SIMILAR SJI STEEL JOIST INSTITUTE STEEL JOIST INSTITUTE SJ SAWED JOINT SAWED JOINT SLV SLEEVE SLEEVE SMACNA SHEET METAL AND AIR CONDITIONING SHEET METAL AND AIR CONDITIONING CONTRACTORS SNT SEALANT SEALANT SOG SLAB ON GRADE SLAB ON GRADE SPEC(S) SPECIFICATION(S) SPECIFICATION(S) SPUF SPRAYED URETHANE FOAM SPRAYED URETHANE FOAM SQ SQUARE SQUARE SS STAINLESS STEEL STAINLESS STEEL STGR(D) STAGGER(ED) STAGGER(ED) STD STANDARD STANDARD STL STEEL STEEL STRUCT STRUCTURAL STRUCTURAL SUB SUBSTITUTE SUBSTITUTE SUPP SUPPLEMENTARY SUPPLEMENTARY SYM SYMMETRICAL SYMMETRICAL SYS SYSTEM SYSTEM T TREAD TREAD T/ TOP TOP T&B TOP AND BOTTOM TOP AND BOTTOM T&G TONGUE AND GROOVE TONGUE AND GROOVE TEMP TEMPORARY; TEMPERATURE TEMPORARY; TEMPERATURE THK THICK THICK THRU THROUGH THROUGH TOC TOP OF CONCRETE TOP OF CONCRETE TOL TOLERANCE TOLERANCE TOT TOTAL TOTAL TOS TOP OF SLAB; TOP OF STEEL TOP OF SLAB; TOP OF STEEL TOW TOP OF WALL TOP OF WALL TWS THRU WALL SCRUPPER THRU WALL SCRUPPER TYP TYPICAL TYPICAL UL UNDERWRITERS LABORATORIES UNDERWRITERS LABORATORIES UNFIN UNFINISHED UNFINISHED UNO UNLESS NOTED OTHERWISE UNLESS NOTED OTHERWISE VENT VENTILATE VENTILATE VERT VERTICAL VERTICAL VNR VENEER VENEER VOL VOLUME VOLUME VP VAPOR PROOF; VENT PIPE VAPOR PROOF; VENT PIPE VS VENT STACK VENT STACK W WEST WEST W/ WITH WITH WD WOOD WOOD WGT WEIGHT WEIGHT WIN WINDOW WINDOW W/O WITHOUT WITHOUT WP WATERPROOF WATERPROOF WPT WORKING POINT WORKING POINT WT WEIGHT; WATERTIGHT WEIGHT; WATERTIGHT WWF WELDED WIRE FABRIC WELDED WIRE FABRIC X BY BY XL EXTRA LARGE EXTRA LARGE YD YARD YARD
AutoCAD SHX Text STANDARD ABBREVIATIONS (NOTE: NOT ALL ABBREVIATIONS ARE USED WITH THIS PROJECT) (NOTE: NOT ALL ABBREVIATIONS ARE USED WITH THIS PROJECT)(NOTE: NOT ALL ABBREVIATIONS ARE USED WITH THIS PROJECT)
AutoCAD SHX Text
VTR
AutoCAD SHX Text
VENT THROUGH ROOF
AutoCAD SHX Text
CONTRACT LIMIT LINE
AutoCAD SHX Text
DEMOLITION LINE
AutoCAD SHX Text
ELEVATION INDICATOR
AutoCAD SHX Text
CENTER LINE INDICATOR
AutoCAD SHX Text
EXISTING TO REMAIN LINE
AutoCAD SHX Text
FEATURES ABOVE LINE INDICATOR
AutoCAD SHX Text
NEW LINE
AutoCAD SHX Text
BREAK, STRAIGHT (SEE SECTION INDICATORS, BUILDING, WITH BREAK STANDARDS)
AutoCAD SHX Text
DETAIL INDICATOR
AutoCAD SHX Text
DETAIL INDICATOR
AutoCAD SHX Text
DETAIL INDICATOR FOR SMALL CONDITIONS
AutoCAD SHX Text
DIMENSION LINE
AutoCAD SHX Text
DRAWING BLOCK TITLE, TYPICAL
AutoCAD SHX Text
ELEVATION INDICATOR, EXTERIOR
AutoCAD SHX Text ARCHITECTURAL SYMBOLS (NOTE: NOT ALL SYMBOLS ARE USED WITH THIS PROJECT)(NOTE: NOT ALL SYMBOLS ARE USED WITH THIS PROJECT)
AutoCAD SHX Text
CENTER LINE
AutoCAD SHX Text
FURNITURE, FIXTURE, & EQUIPMENT INDICATOR
AutoCAD SHX Text
GRAPHIC SCALE, "=1'-0"18"=1'-0"
AutoCAD SHX Text
DRAWING BLOCK TITLE
AutoCAD SHX Text 1 1/2" = 1'-0"
AutoCAD SHX Text C4
AutoCAD SHX Text 1 1/2'
AutoCAD SHX Text 1/2'
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text A-201
AutoCAD SHX Text A4
AutoCAD SHX Text
AutoCAD SHX Text 16'
AutoCAD SHX Text 8'
AutoCAD SHX Text 4'
AutoCAD SHX Text
AutoCAD SHX Text A-201
AutoCAD SHX Text A4
AutoCAD SHX Text A-512
AutoCAD SHX Text D2
AutoCAD SHX Text A-512
AutoCAD SHX Text D2
AutoCAD SHX Text A-512
AutoCAD SHX Text D2
AutoCAD SHX Text C
AutoCAD SHX Text L
AutoCAD SHX Text
KEYNOTE
AutoCAD SHX Text
NORTH ARROW
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
MATERIALS LEGEND
AutoCAD SHX Text
RIGID INSULATION
AutoCAD SHX Text V V ITEM - VA SUPPLIED & INSTALLED VC ITEM - VA SUPPLIED & CONTRACTOR INSTALLED CC ITEM - CONTRACTOR SUPPLIED & INSTALLED
AutoCAD SHX Text A4
AutoCAD SHX Text A-201
AutoCAD SHX Text
DETAIL NUMBER
AutoCAD SHX Text
AutoCAD SHX Text A4.3
AutoCAD SHX Text
SECTION INDICATOR
AutoCAD SHX Text
DETAIL INDICATOR
AutoCAD SHX Text
SHEET WHERE REFERENCED OR DRAWN
AutoCAD SHX Text
BATT INSULATION
AutoCAD SHX Text
CONCRETE (EXISTING)
AutoCAD SHX Text
BRICK (EXISTING)
AutoCAD SHX Text
EARTH (EXISTING)
AutoCAD SHX Text
METAL DECKING
AutoCAD SHX Text
GYPSUM BD.
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
COLUMN GRID
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING DOOR / OPENING
AutoCAD SHX Text Affairs
AutoCAD SHX Text Veterans
1. EXISTING ADJACENT ROOMS, ABOVE AND BELOW WILL REMAIN OCCUPIED DURING
CONSTRUCTION. NO DISRUPTION OF BUILDING SYSTEMS OR OPERATIONS ARE
PERMITTED WITHOUT PRIOR APPROVAL BY THE BUILDING OWNER.
2. REFER TO NEW CONSTRUCTION PLANS TO COORDINATE THE EXTENT OF DEMOLITION
WITH NEW CONSTRUCTION.
3. DEMOLITION OF BUILDING SYSTEMS INCLUDING CONDUIT AND WIRING MAY EXTEND
BEYOND THE LIMITS SHOWN ON THE DEMOLITION PLANS. THIS WORK SHALL BE
INCLUDED IN THE CONTRACTORS SCOPE OF WORK.
4. THE GENERAL CONTRACTOR SHALL SEAL OR PROVIDE FILTERS ON ALL REMAINING
DUCTWORK TO PREVENT INFILTRATION OF DUST. MAINTAIN FILTERS AS REQUIRED.
5. GENERAL CONTRACTOR SHALL MAINTAIN EGRESS AND INTEGRITY OF LIFE SAFETY
SYSTEMS DURING ALL DEMOLITION AND NEW CONSTRUCTION.
6. PROTECT EXISTING MTL CANOPIES TO REMAIN DURING CONSTRUCTION.
7. BUILDING 5 WILL REMAIN FULLY OPERATIONAL DURING THE CONSTRUCTION PERIOD.
OVERHEAD PROTECTION AT ALL EXTERIOR EXIT-WAYS (EXIT-WAYS AT THE GROUND
LEVEL AND UPPER LEVELS) IS A REQUIREMENT OF THIS CONTRACT FOR THE
PROTECTION OF THE SALEM VA MEDICAL CENTER STAFF AND THE GENERAL PUBLIC.
D
AD
F4
AD201
F1 AD
D-5 D-5 D-5 D-5
D-5 D-5
D-3
ATTIC SPACE
D-10
D-4 D-4
D-11
D-1
D-11
D-1
D
AD
D4
AD201
F4
AD201
F1 AD
D-9D-9D-9D-9D-9
D-1
D-1
D-1
D-1
D-1
D-1
D-1
D-1
D-1
D-1
D-9D-9 D-9 D-9 D-9D-9D-9D-9
D-1 D-1 D-1
D-2
D-2
D-2
D-2
D-2 D-2
D-2 D-2
D-2 D-2
D-2 D-2
D-2
D-2
D-2
D-2
D-2 D-2
D-2D-2
D-2
D-7D-7
D-10
D-6 D-6
D-6
D-6
D-6
D-6
D-6
D-6
D-6
D-6D-6
D-6
D-6
D-6
D-6
D-6
D-6
EXISTING RAMP TO REMAIN
EXISTING
CONNECTING
CORRIDOR TO
REMAIN
D-3
D-1
D-1
D-1
D-1
D-2
D-4D-4
D-13 D-13
D-13
D-13
D-13
D-13
D-12
D-12
D-12
D-12
D-12
D-12
D-12
D-12
D-12
D-12
D-12
D-12
D-12
D-12
D-12
D-12
D-12
D-12 D-12
D-12
D-12
D-12
D-12
1. DEMOLISH EXISTING SLATE ROOF TILES AND ALL DAMAGED WOOD SUBSTRATE.
2. DEMOLISH ALL EXISTING FLASHING IN ROOF VALLEYS AND HIPS.
3. REMOVE FABRIC AWNING PRIOR TO ROOF DEMOLITION. REINSTALL IN SAME
LOCATION.
4. REMOVE METAL AWNING PRIOR TO ROOF DEMOLITION. REINSTALL IN SAME
LOCATION.
5. DEMOLISH EXISTING DORMER LOUVERS & WOOD TRIM.
6. DEMOLISH INTEGRAL GUTTER & COPPER COVER.
7. DEMOLISH EXISTING COPPER CHIMNEY CAP.
8. DEMOLISH EXISTING DOWNSPOUTS.
9. DEMOLISH EXISTING SLATE TILE FROM VERTICAL SURFACE OF DORMER.
10. DEMOLISH EXISTING ASPHALT ROOF & COPING.
11. DEMOLISH EXISTING CEMEMTITIOUS FINISH MATERIAL ON TOP OF ROOFING.
12. REMOVE UP TO 250LF (LINEAR FEET) OF WOOD CORNICE BELOW THE BUILT-IN COPPER GUTTER
THAT IS DETERIORATED BEYOND THE ABILITY TO SCRAPE/PRIME/REPAINT.
13. REMOVE UP TO 100LF (LINEAR FEET) OF WOOD CORNICE AT THE GABLE ENDS THAT IS
DETERIORATED BEYOND THE ABILITY TO SCRAPE/PRIME/REPAINT.
D-#
N
FINAL CONSTRUCTION DOCUMENTS
Af fa ir s
Ve te ra ns
Approved: Infection Control Officer
Approved: Safety Manager
Approved: GEMS Coordinator
Approved: Energy Engineer
Approved: Associate Director
Approved: Chief of Staff
Approved: Service Chief th re e inc he s = o ne fo ot on e an d on e-ha lf i nc he s = o ne fo ot on e inc h on e fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf i nc h on e fo ot th re e-eig ht s i nc h on e fo ot on e-qu ar te r i nc h on e fo ot on e-eig ht in ch o ne fo ot
DRAWING NO.
Dwg. Of
Project No.
Date
DrawnChecked
Location
Building Number
Project Title
Approved: Medical Center Director
Approved: Chief of Facility Management Svc.
Drawing Title
DateRevisions
BUILDING 5
VA MEDICAL CENTER, SALEM, VA 24153
REPLACE ROOF AND TUCKPOINT (BUILDING 5)
102 3rd Ave., NE Hickory, NC 28601
828.315.9962 www.atriaxgroup.com
2105 Water Ridge Pkwy #
Charlotte, NC 28217 704.535.6374 www.wmba.net
Quality Consulting Engineers, PLLC
6277-600 Carolina Commons Drive, #
Indian Land SC 29707 803.207.5450 djones@qualityconsultingengineers.com 12
1 2 3 4 5 6 7 8
A
B
C
D
E
F
658-16-101
C :\U se rs
\s c h ei ke la r d
\D oc u m en ts \3
8_
VA
S al em b ld g
R oo f R e p la ce m en t_ Ar c h _S ar a C he ik el ar d.
rv t
/2 2/
:5
9:
A
M DEMOLITION PLANS
22 OCTOBER 2018
22 OCTOBER 2018
AD101
BSR PDH
DEMOLITION GENERAL NOTES
1/8" = 1'-0"C1 FLR - ATTIC SLAB - DEMO
1/8" = 1'-0"F1 FLR - ROOF - DEMO
DEMOLITION ROOF KEYED NOTES
1/16" = 1'-0"F7 FLR - ROOF - NEW PHASING
NOTE: GC TO FOLLOW PHASING & PROPOSE SCHEDULES
WITH THEIR BID.
1. EXISTING ADJACENT ROOMS, ABOVE AND BELOW WILL REMAIN OCCUPIED DURING
CONSTRUCTION. NO DISRUPTION OF BUILDING SYSTEMS OR OPERATIONS ARE
PERMITTED WITHOUT PRIOR APPROVAL BY THE BUILDING OWNER.
2. REFER TO NEW CONSTRUCTION PLANS TO COORDINATE THE EXTENT OF DEMOLITION
WITH NEW CONSTRUCTION.
3. DEMOLITION OF BUILDING SYSTEMS INCLUDING CONDUIT AND WIRING MAY EXTEND
BEYOND THE LIMITS SHOWN ON THE DEMOLITION PLANS. THIS WORK SHALL BE
INCLUDED IN THE CONTRACTORS SCOPE OF WORK.
4. THE GENERAL CONTRACTOR SHALL SEAL OR PROVIDE FILTERS ON ALL REMAINING
DUCTWORK TO PREVENT INFILTRATION OF DUST. MAINTAIN FILTERS AS REQUIRED.
5. GENERAL CONTRACTOR SHALL MAINTAIN EGRESS AND INTEGRITY OF LIFE SAFETY
SYSTEMS DURING ALL DEMOLITION AND NEW CONSTRUCTION.
6. PROTECT EXISTING MTL CANOPIES TO REMAIN DURING CONSTRUCTION.
7. BUILDING 5 WILL REMAIN FULLY OPERATIONAL DURING THE CONSTRUCTION PERIOD.
OVERHEAD PROTECTION AT ALL EXTERIOR EXIT-WAYS (EXIT-WAYS AT THE GROUND
LEVEL AND UPPER LEVELS) IS A REQUIREMENT OF THIS CONTRACT FOR THE
PROTECTION OF THE SALEM VA MEDICAL CENTER STAFF AND THE GENERAL PUBLIC.
BASEMENT LEVEL
78'-0"
LEVEL 01
89'-0"
LEVEL 02
101'-0"
ATTIC SLAB
112'-7"
TOP OF CHIMNEY
138'-11 1/2"
D-1
D-1
D-8
D-1
D-7
D-1
D-1
D-8
'-4
/2
'-7
'-0
'-0
D-6
D-6
D-6D-6
D-3
D-10
D-12
D-12D-12D-12
BASEMENT LEVEL
78'-0"
LEVEL 01
89'-0"
LEVEL 02
101'-0"
ATTIC SLAB
112'-7"
TOP OF CHIMNEY
138'-11 1/2"
D-1D-1D-1D-1D-1
D-1
D-7
D-1
D-8
D-8
D-7
D-5D-5
D-2 D-2
D-2D-2
D-1
D-1
'-0
'-0
'-7
'-4
/2
D-6D-6
D-6
D-6
D-3
D-6 D-6
D-4 D-4
D-11
D-12 D-12 D-12
D-13 D-13
D-12
BASEMENT LEVEL
78'-0"
LEVEL 01
89'-0"
LEVEL 02
101'-0"
ATTIC SLAB
112'-7"
TOP OF CHIMNEY
138'-11 1/2"
D-7
D-2
D-5
D-1
D-5
D-1D-1D-1
D-5
D-1
D-5
D-1
D-1
D-1
D-1
D-8
D-1
D-1
D-8
D-10
D-7
D-2
D-2
D-8
D-8 D-8
'-4
/2
'-7
'-0
'-0
D-6
D-6
D-6
D-6 D-6 D-6 D-6 D-6
D-12
D-12
D-13
D-12
D-13 D-13
D-12 D-12
D-12
D-12 D-12
BASEMENT LEVEL
78'-0"
LEVEL 01
89'-0"
LEVEL 02
101'-0"
ATTIC SLAB
112'-7"
TOP OF CHIMNEY
138'-11 1/2"
D-10
D-1
D-7
D-1
D-1
D-1
D-8D-8
D-2D-2
D-2D-2
D-1 26 '-4
/2
'-7
'-0
'-0
D-6
D-6D-6
D-6D-6
D-6
D-10
D-3
D-13
D-12
D-12
D-12
D-12
D-12 D-12
D-12
1. DEMOLISH EXISTING SLATE ROOF TILES AND ALL DAMAGED WOOD SUBSTRATE.
2. DEMOLISH ALL EXISTING FLASHING IN ROOF VALLEYS AND HIPS.
3. REMOVE FABRIC AWNING PRIOR TO ROOF DEMOLITION. REINSTALL IN SAME
LOCATION.
4. REMOVE METAL AWNING PRIOR TO ROOF DEMOLITION. REINSTALL IN SAME
LOCATION.
5. DEMOLISH EXISTING DORMER LOUVERS & WOOD TRIM.
6. DEMOLISH INTEGRAL GUTTER & COPPER COVER.
7. DEMOLISH EXISTING COPPER CHIMNEY CAP.
8. DEMOLISH EXISTING DOWNSPOUTS.
9. DEMOLISH EXISTING SLATE TILE FROM VERTICAL SURFACE OF DORMER.
10. DEMOLISH EXISTING ASPHALT ROOF & COPING.
11. DEMOLISH EXISTING CEMEMTITIOUS FINISH MATERIAL ON TOP OF ROOFING.
12. REMOVE UP TO 250LF (LINEAR FEET) OF WOOD CORNICE BELOW THE BUILT-IN COPPER GUTTER
THAT IS DETERIORATED BEYOND THE ABILITY TO SCRAPE/PRIME/REPAINT.
13. REMOVE UP TO 100LF (LINEAR FEET) OF WOOD CORNICE AT THE GABLE ENDS THAT IS
DETERIORATED BEYOND THE ABILITY TO SCRAPE/PRIME/REPAINT.
D-#
N
FINAL CONSTRUCTION DOCUMENTS
Af fa ir s
Ve te ra ns
Approved: Infection Control Officer
Approved: Safety Manager
Approved: GEMS Coordinator
Approved: Energy Engineer
Approved: Associate Director
Approved: Chief of Staff
Approved: Service Chief th re e inc he s = o ne fo ot on e an d on e-ha lf i nc he s = o ne fo ot on e inc h on e fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf i nc h on e fo ot th re e-eig ht s i nc h on e fo ot on e-qu ar te r i nc h on e fo ot on e-eig ht in ch o ne fo ot
DRAWING NO.
Dwg. Of
Project No.
Date
DrawnChecked
Location
Building Number
Project Title
Approved: Medical Center Director
Approved: Chief of Facility Management Svc.
Drawing Title
DateRevisions
BUILDING 5
VA MEDICAL CENTER, SALEM, VA 24153
REPLACE ROOF AND TUCKPOINT (BUILDING 5)
102 3rd Ave., NE Hickory, NC 28601
828.315.9962 www.atriaxgroup.com
2105 Water Ridge Pkwy #
Charlotte, NC 28217 704.535.6374 www.wmba.net
Quality Consulting Engineers, PLLC
6277-600 Carolina Commons Drive, #
Indian Land SC 29707 803.207.5450 djones@qualityconsultingengineers.com 12
1 2 3 4 5 6 7 8
A
B
C
D
E
F
658-16-101
C :\U se rs
\s c h ei ke la r d
\D oc u m en ts \3
8_
VA
S al em b ld g
R oo f R e p la ce m en t_ Ar c h _S ar a C he ik el ar d.
rv t
/2 2/
:0
0:
A
M DEMOLITION ELEVATIONS
22 OCTOBER 2018
22 OCTOBER 2018
AD201
BSR PDH
DEMOLITION GENERAL NOTES
1/8" = 1'-0"D1 NORTHEAST ELEVATION DEMO
1/8" = 1'-0"D4 NORTHWEST ELEVATION DEMO
1/8" = 1'-0"F4 SOUTHEAST ELEVATION DEMO
1/8" = 1'-0"F1 SOUTHWEST ELEVATION DEMO
DEMOLITION ROOF KEYED NOTES
EXISTING RAMP TO REMAIN
EXISTING
CONNECTING
CORRIDOR TO
REMAIN
EXISTING BUILDING
1 HR FIRE RATED ENCLOSURE TO 10' AWAY
FROM BUILDING PERIMETER FOR
OVERHEAD PROTECTION. MAINTAIN 4'
INSIDE CLEAR MINIMUM.
EXIT
10' BUILDING PERIMETER
4'-0"4'-0"
4'-0" 4'-0"
NOTE: BUILDING 5 WILL REMAIN FULLY OPERATIONAL DURING
THE CONSTRUCTION PERIOD. OVERHEAD PROTECTION AT ALL
EXTERIOR EXIT-WAYS (EXIT-WAYS AT THE GROUND LEVEL AND
UPPER LEVELS) IS A REQUIREMENT OF THIS CONTRACT FOR
THE PROTECTION OF THE SALEM VA MEDICAL CENTER STAFF
AND THE GENERAL PUBLIC.
N
FINAL CONSTRUCTION DOCUMENTS
Af fa ir s
Ve te ra ns
Approved: Infection Control Officer
Approved: Safety Manager
Approved: GEMS Coordinator
Approved: Energy Engineer
Approved: Associate Director
Approved: Chief of Staff
Approved: Service Chief th re e inc he s = o ne fo ot on e an d on e-ha lf i nc he s = o ne fo ot on e inc h on e fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf i nc h on e fo ot th re e-eig ht s i nc h on e fo ot on e-qu ar te r i nc h on e fo ot on e-eig ht in ch o ne fo ot
DRAWING NO.
Dwg. Of
Project No.
Date
DrawnChecked
Location
Building Number
Project Title
Approved: Medical Center Director
Approved: Chief of Facility Management Svc.
Drawing Title
DateRevisions
BUILDING 5
VA MEDICAL CENTER, SALEM, VA 24153
REPLACE ROOF AND TUCKPOINT (BUILDING 5)
102 3rd Ave., NE Hickory, NC 28601
828.315.9962 www.atriaxgroup.com
2105 Water Ridge Pkwy #
Charlotte, NC 28217 704.535.6374 www.wmba.net
Quality Consulting Engineers, PLLC
6277-600 Carolina Commons Drive, #
Indian Land SC 29707 803.207.5450 djones@qualityconsultingengineers.com 12
1 2 3 4 5 6 7 8
A
B
C
D
E
F
658-16-101
C :\U se rs
\s c h ei ke la r d
\D oc u m en ts \3
8_
VA
S al em b ld g
R oo f R e p la ce m en t_ Ar c h _S ar a C he ik el ar d.
rv t
/2 0/
0:
:2
AM EXIT PROTECTION PLAN
22 OCTOBER 2018
22 OCTOBER 2018
AE100
Designer Checker
1/8" = 1'-0"F1 SITE - LEVEL 01 - NEW
1. INSTALL NEW LOUVER AND NEW FLASHING. PAINT EXPOSED TRIM.
2. INSTALL NEW WOOD SUBSTRATE WHERE IT WAS DEMOLISHED AND INSTALL NEW SLATE ROOF & FLASHINGS.
3. RECAP EXISTING CHIMNEY. TUCKPOINT & REPAIR ANY DAMAGED BRICK.
4. INSTALL NEW WOOD TRIM AND COPPER INTEGRAL GUTTER.
5. INSTALL NEW FLAT ROOF WITH GRAVEL STOP & COPING TO MATCH EXISTING.
6. INSTALL NEW DRIP EDGE ONLY.
7. INSTALL NEW SLATE TILE ON VERTICAL SURFACES OF DORMERS.
8. INSTALL NEW DOWNSPOUTS.
9. REINSTALL BUILDING SIGNAGE. .
10. REINSTALL METAL CANOPIES.
11. REINSTALL FABRIC AWNING.
12. INSTALL NEW PEDESTRIAN TRAFFIC COATING (PRIME AND WEARING COATS). PREPARE SURFACE AS REQUIRED TO
RECEIVE COATING.
13. REPLACE UP TO 250LF (LINEAR FEET) OF WOOD CORNICE BELOW THE BUILT-IN COPPER GUTTER TO MATCH THE EXISTING CORNICE IN PROFILE AND FINISH, THE REMAINING CORNICE IS TO BE SCRAPED, PRIMED, AND PAINTED.
14. REPLACE UP TO 100LF (LINEAR FEET) OF WOOD CORNICE AT THE GABLE ENDS TO MATCH THE EXISTING CORNICE IN PROFILE AND FINISH, THE REMAINING CORNICE AT THE GABLE ENDS IS TO BE SCRAPED, PRIMED, AND PAINTED.
15. SCRAPE, PRIME, AND REPAINT WOOD GABLE END MEDALLION
C
AE
F4
AE201
C4
AE201
F1 AE
2'-10"
1 1 1
2'-10 1/2"
'-8
/2
'-8
/2
2'-10 1/2"
6 6 6
C
AE
F4
AE201
F1 AE
1 33
2 2 2
7 777 7 7
7 7777 7
F4
AE303
TYP
F6
AE304
TYP
B4
AE303
TYP
B1
AE303
TYP
B4
AE303
TYP
B1
AE303
TYP
F4
AE304
TYP
AE101
C6
D1
AE304
TYP
D4
AE304
TYP
B4
AE303
TYP
B4
AE303
TYP
B1
AE303
TYP
B1
AE303
TYP
B4
AE303
TYP
F6
AE304
TYP
B4
AE303
TYP
B4
AE303
TYP
B4
AE303
TYP
B1
AE303
TYP
F6
AE304
TYP
F6
AE304
TYP
B1
AE303
TYP
B4
AE303
TYP
B4
AE303
TYP
F6
AE304
TYP
EXISTING RAMP TO REMAIN
EXISTING
CONNECTING
CORRIDOR TO
REMAIN
4 4
AE101
E7
4'-0" 28'-6 3/8" 28'-10 7/8" 17'-0 1/2" 28'-11 1/8" 28'-5 7/8" 4'-0 5/8" 4'-0"
7' -9
'-1
3/ 8"
7' -8
/2
D4
AE304
TYP
6 14
614 14
D7
AE303
TYP
D4
AE303
TYP
B1
AE303
TYP
F1
AE303
TYP
C
AE
D1
AE306
D4
AE306
D4
AE306
AE306
B8
ETR ROOF HATCH
ETR ROOF DRAIN
ETR E.F.
ETR COPPER ROOFING BELOW
VIF
19'-11 1/4"
N
FINAL CONSTRUCTION DOCUMENTS
Af fa ir s
Ve te ra ns
Approved: Infection Control Officer
Approved: Safety Manager
Approved: GEMS Coordinator
Approved: Energy Engineer
Approved: Associate Director
Approved: Chief of Staff
Approved: Service Chief th re e inc he s = o ne fo ot on e an d on e-ha lf i nc he s = o ne fo ot on e inc h on e fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf i nc h on e fo ot th re e-eig ht s i nc h on e fo ot on e-qu ar te r i nc h on e fo ot on e-eig ht in ch o ne fo ot
DRAWING NO.
Dwg. Of
Project No.
Date
DrawnChecked
Location
Building Number
Project Title
Approved: Medical Center Director
Approved: Chief of Facility Management Svc.
Drawing Title
DateRevisions
BUILDING 5
VA MEDICAL CENTER, SALEM, VA 24153
REPLACE ROOF AND TUCKPOINT (BUILDING 5)
102 3rd Ave., NE Hickory, NC 28601
828.315.9962 www.atriaxgroup.com
2105 Water Ridge Pkwy #
Charlotte, NC 28217 704.535.6374 www.wmba.net
Quality Consulting Engineers, PLLC
6277-600 Carolina Commons Drive, #
Indian Land SC 29707 803.207.5450 djones@qualityconsultingengineers.com 12
1 2 3 4 5 6 7 8
A
B
C
D
E
F
658-16-101
C :\U se rs
\s c h ei ke la r d
\D oc u m en ts \3
8_
VA
S al em b ld g
R oo f R e p la ce m en t_ Ar c h _S ar a C he ik el ar d.
rv t
/2 0/
0:
:4
AM NEW ATTIC AND ROOF PLANS
22 OCTOBER 2018
22 OCTOBER 2018
AE101
BSR PDH
KEYED NOTES - NEW WORK
1/8" = 1'-0"C1 FLR - ATTIC SLAB - NEW
1/8" = 1'-0"F1 FLR - ROOF - NEW
1/4" = 1'-0"C6 FLR - ROOF - NEW - ENLARGED DORMER PLAN
1/4" = 1'-0"E7 ENLARGED FLAT ROOF PLAN
EXISTING RAMP TO REMAIN
EXISTING
CONNECTING
CORRIDOR TO
REMAIN
ETR AWNING ETR AWNING
SNOW GUARD LOCATIONS
AE101A
E7
TYP
1"
4 1/8"
3/
4"
1. SNOW GUARD LAYOUT MAY VARY
DEPENDING ON MANUFACTURER. SUBMIT
SNOW GUARD LAYOUT W/ SUBMITTALS.
2. SNOW GUARD MANUFACTURER SHALL USE
GROUND SNOW LOAD OF 30PSF WHEN
DESIGNING SNOW GUARD LAYOUTS.
No.100 SNOWGUARD ASSEMBLY
BY "BERGER BROS. CO."
60˚
1"
2"
1'-5 1/2"
VI
F
EQ
VI
F
EQ
RIDGE (TOP OF ROOF)
EAVE (BOTT. OF ROOF)
X X X X X X X
X X X X X X X X X X X X X X
2'-0" TYP
LOCATE SECOND GROUP OF SNOW
GUARDS MIDWAY UP ROOF SLOPE.
REVERSE SPACING FROM FIRST
GROUP PATTERN, AS SHOWN.
START THIRD ROW OR SNOW
GUARD ASSEMBLY UP TWO (2)
ROWS OF SLATE FROM THE
SECOND ROW. CENTER
BETWEEN GUARDS ON SECOND
ROW.
START SECOND ROW OF SNOW
GUARD ASSEMBLY TWO (2) ROWS
OF SLATE ABOVE THE FIRST ROW
OF SNOW GUARDS. CENTER
BETWEEN GUARDS ON FIRST ROW.
SNOW GUARD ASSEMBLY.
BEGIN FIRST ROW AT BOTTOM
OF SECOND SLATE COURSE
AND INSTALL AT 2'-0" O/C
HORIZONTALLY.
NOTE: CONTRACTOR SHALL VERIFY
QUANTITY OF SNOW GUARDS
REQUIRED PER ROOF AREA PRIOR
TO BID AND ORDERING OF
MATERIALS.
XXXXXXX
XXXXXXX
XXXXXXX
N
FINAL CONSTRUCTION DOCUMENTS
Af fa ir s
Ve te ra ns
Approved: Infection Control Officer
Approved: Safety Manager
Approved: GEMS Coordinator
Approved: Energy Engineer
Approved: Associate Director
Approved: Chief of Staff
Approved: Service Chief th re e inc he s = o ne fo ot on e an d on e-ha lf i nc he s = o ne fo ot on e inc h on e fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf i nc h on e fo ot th re e-eig ht s i nc h on e fo ot on e-qu ar te r i nc h on e fo ot on e-eig ht in ch o ne fo ot
DRAWING NO.
Dwg. Of
Project No.
Date
DrawnChecked
Location
Building Number
Project Title
Approved: Medical Center Director
Approved: Chief of Facility Management Svc.
Drawing Title
DateRevisions
BUILDING 5
VA MEDICAL CENTER, SALEM, VA 24153
REPLACE ROOF AND TUCKPOINT (BUILDING 5)
102 3rd Ave., NE Hickory, NC 28601
828.315.9962 www.atriaxgroup.com
2105 Water Ridge Pkwy #
Charlotte, NC 28217 704.535.6374 www.wmba.net
Quality Consulting Engineers, PLLC
6277-600 Carolina Commons Drive, #
Indian Land SC 29707 803.207.5450 djones@qualityconsultingengineers.com 12
1 2 3 4 5 6 7 8
A
B
C
D
E
F
658-16-101
C :\U se rs
\s c h ei ke la r d
\D oc u m en ts \3
8_
VA
S al em b ld g
R oo f R e p la ce m en t_ Ar c h _S ar a C he ik el ar d.
rv t
/2 0/
0:
:4
AM SNOW GUARD LOCATIONS ROOF PLAN
22 OCTOBER 2018
22 OCTOBER 2018
AE101A
SEC PDH
1/8" = 1'-0"F1 FLR - ROOF - NEW SNOW GUARD LOCATIONS PLAN
3" = 1'-0"F7 TYPICAL SNOWGUARD BRACKET
3" = 1'-0"E7 TYPICAL SNOWGUARD LAYOUT
BASEMENT LEVEL
78'-0"
LEVEL 01
89'-0"
LEVEL 02
101'-0"
ATTIC SLAB
112'-7"
TOP OF CHIMNEY
138'-11 1/2"
2 2
8 8
D4
AE304
TYP
D4
AE304
TYP
D4
AE304
TYP
'-4
/2
'-7
'-0
'-0
ETR BRICK
ETR STONE
AE305
F4
BASEMENT LEVEL
78'-0"
LEVEL 01
89'-0"
LEVEL 02
101'-0"
ATTIC SLAB
112'-7"
TOP OF CHIMNEY
138'-11 1/2"
1 1
7 7
AE302
C1
TYP
D4
AE304
TYP
F6
AE304
TYP
BUILDING GRADE
STREET GRADE
ETR RETAINING
WALL
'-0
'-0
'-7
'-4
/2
ETR BRICK
ETR STONE
ETR RAMP
4 4 4
F6
AE305
TYP
C6
AE304
TYP
13 13
BASEMENT LEVEL
78'-0"
LEVEL 01
89'-0"
LEVEL 02
101'-0"
ATTIC SLAB
112'-7"
TOP OF CHIMNEY
138'-11 1/2"
3 3
2 25
7 77 77
2 2 2 22 2
8 8
AE302
C1
TYP
D4
AE304
TYP
F6
AE304
TYP
C6
AE304
TYP
'-4
/2
'-7
'-0
'-0
ETR BRICK
ETR STONE
6 6
F6
AE305
TYP
15 15
BASEMENT LEVEL
78'-0"
LEVEL 01
89'-0"
LEVEL 02
101'-0"
ATTIC SLAB
112'-7"
TOP OF CHIMNEY
138'-11 1/2"
2 5
F6
AE304
TYP
D4
AE304
TYP
D4
AE304
TYP
'-4
/2
'-7
'-0
'-0
ETR BRICK
ETR STONE
NEW SLATE ROOF
AE305
F4
13 13
1. INSTALL NEW LOUVER AND NEW FLASHING. PAINT EXPOSED TRIM.
2. INSTALL NEW WOOD SUBSTRATE WHERE IT WAS DEMOLISHED AND INSTALL NEW SLATE ROOF & FLASHINGS.
3. RECAP EXISTING CHIMNEY. TUCKPOINT & REPAIR ANY DAMAGED BRICK.
4. INSTALL NEW WOOD TRIM AND COPPER INTEGRAL GUTTER.
5. INSTALL NEW FLAT ROOF WITH GRAVEL STOP & COPING TO MATCH EXISTING.
6. INSTALL NEW DRIP EDGE ONLY.
7. INSTALL NEW SLATE TILE ON VERTICAL SURFACES OF DORMERS.
8. INSTALL NEW DOWNSPOUTS.
9. REINSTALL BUILDING SIGNAGE. .
10. REINSTALL METAL CANOPIES.
11. REINSTALL FABRIC AWNING.
12. INSTALL NEW PEDESTRIAN TRAFFIC COATING (PRIME AND WEARING COATS). PREPARE SURFACE AS REQUIRED TO
RECEIVE COATING.
13. REPLACE UP TO 250LF (LINEAR FEET) OF WOOD CORNICE BELOW THE BUILT-IN COPPER GUTTER TO MATCH THE EXISTING CORNICE IN PROFILE AND FINISH, THE REMAINING CORNICE IS TO BE SCRAPED, PRIMED, AND PAINTED.
14. REPLACE UP TO 100LF (LINEAR FEET) OF WOOD CORNICE AT THE GABLE ENDS TO MATCH THE EXISTING CORNICE IN PROFILE AND FINISH, THE REMAINING CORNICE AT THE GABLE ENDS IS TO BE SCRAPED, PRIMED, AND PAINTED.
15. SCRAPE, PRIME, AND REPAINT WOOD GABLE END MEDALLION
N
FINAL CONSTRUCTION DOCUMENTS
Af fa ir s
Ve te ra ns
Approved: Infection Control Officer
Approved: Safety Manager
Approved: GEMS Coordinator
Approved: Energy Engineer
Approved: Associate Director
Approved: Chief of Staff
Approved: Service Chief th re e inc he s = o ne fo ot on e an d on e-ha lf i nc he s = o ne fo ot on e inc h on e fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf i nc h on e fo ot th re e-eig ht s i nc h on e fo ot on e-qu ar te r i nc h on e fo ot on e-eig ht in ch o ne fo ot
DRAWING NO.
Dwg. Of
Project No.
Date
DrawnChecked
Location
Building Number
Project Title
Approved: Medical Center Director
Approved: Chief of Facility Management Svc.
Drawing Title
DateRevisions
BUILDING 5
VA MEDICAL CENTER, SALEM, VA 24153
REPLACE ROOF AND TUCKPOINT (BUILDING 5)
102 3rd Ave., NE Hickory, NC 28601
828.315.9962 www.atriaxgroup.com
2105 Water Ridge Pkwy #
Charlotte, NC 28217 704.535.6374 www.wmba.net
Quality Consulting Engineers, PLLC
6277-600 Carolina Commons Drive, #
Indian Land SC 29707 803.207.5450 djones@qualityconsultingengineers.com 12
1 2 3 4 5 6 7 8
A
B
C
D
E
F
658-16-101
C :\U se rs
\s c h ei ke la r d
\D oc u m en ts \3
8_
VA
S al em b ld g
R oo f R e p la ce m en t_ Ar c h _S ar a C he ik el ar d.
rv t
/2 0/
0:
:5
AM EXTERIOR ELEVATIONS
22 OCTOBER 2018
22 OCTOBER 2018
AE201
ANG PDH
1/8" = 1'-0"C1 NORTHEAST ELEVATION
1/8" = 1'-0"C4 NORTHWEST ELEVATION
1/8" = 1'-0"F4 SOUTHEAST ELEVATION
1/8" = 1'-0"F1 SOUTHWEST ELEVATION
KEYED NOTES - NEW WORK
EXISTING T&G SHEATHING
WALL UNDERLAYMENT
EXISTING T&G DECKING
ICE/WATER SHIELD
UNDERLAYMENT
BASE FLASHING (TYP)
4"
8"
1" T
O G
AP
3"
ICE/WATER SHIELD UNDERLAYMENT, TYP
SLATE SHINGLES
COPPER DRIP EDGE WITH
INTEGRAL CANT. MECH
ATTACHED @ 6" O.C AND
SET IN WATER CUT-OFF
MASTIC
WOOD FASCIA
METAL LOUVERS
7/
8"
3/ 8"
COPPER FLASHING.
MECH. ATTACHED @
6" O.C AND SET IN
WATER CUT-OFF MASTIC
SLATE SHINGLES
ICE/WATER SHIELD
UNDERLAYMENT, TYP
EXISTING T&G
DECKING
EXISTING FRAMING
VIF
A2
AE301
B2
AE301
C2
AE301
FIELD SLATE SHINGLES
RAKE FLASHING (TYP.)
ICE/WATER SHIELD
UNDERLAYMENT
EXISTING T&G DECKING
TYP
6" MIN
1"±
ICE/WATER SHIELD
UNDERLAYMENT
FIELD SLATE
SHINGLES
EXISTING T&G
DECKING
NAIL @ 16" O.CEXISTING RAKE
BOARD
RAKE FLASHING
TYP
1/
2"
3"
RAGGLE (SAW CUT)
1 1/2" MIN
HOOK DAM
LEAD WEDGE
BACKER ROD
AND SEALANT
COUNTERFLASHING (TYP.)
BASE FLASHING (TYP.)
1/2" HEM
ICE/WATER SHIELD
UNDERLAYMENT
EXISTING T&G DECKING
EXISTING
MASONRY
WALL
LE
NGTH
EXPOSURE
+ H
EADLA
P
+ 1 " T
O 2"
(N
AILI
NG
FLA
NGE)
4"
MIN.
1/4 " T
O 1/ 2"
NAIL BASE FLASHING
ABOVE TOP EDGE OF
SLATE.
EXISTING T&G DECKING
BASE FLASHING (TYP.)
ALTERNATIVE NAIL LOCATION
FIELD SLATE SHINGLES
ICE/WATER
SHIELD UNDERLAYMENT
8" M
IN
1' -0
" M
IN
4"
MIN
. L
AP
4"
MIN
8" M
IN
1/2" TO
1" GAP1/2"
HEM
IF THE COUNTERFLASHING HEIGHT IS GREATER
THAN 8", A HEAVY GAUGE COPPER CLIP
SHALL
BE SOLDERED TO THE UNDERLYING
COUNTERFLASHING AND FOLDED OVER THE
OVERLYING COUNTERFLASHING AS SHOWN
CENTERED VERTICALLY.
C
UT
A W
AY
V
IE
W
COUNTERFLASHING (TYP.)
UNDERLYING
BASE FLASHING (TYP)
FIELD STALE SHINGLES
EXISTING T&G DECKING
ICE/WATER SHIELD
UNDERLAYMENT
BASE FLASHING
(TYP.)
EXSTING MASONRY
2"
JOINT SEALANT
ICE/WATER SHIELD WALL
UNDERLAYMENT
COPPER DORMER WALL
FLASHING, CONTINUOUS
FULL HEIGHT OF WINDOW.
EXTEND TOP END BEHIND
CROWN MOLDING 1" MIN.
1/2" HOOK DAM,
FLATTEN TO ALLOW
SLATE TO LIE FLAT
HEM TO PROVIDE
CLEAN EDGE
BEND FOR SNUG FIT
TO OUTSIDE CASING.
EXISTING WALL SHEATHING
EXISTING FRAMING
+/- 1/2"
3 3/4" 6 1/4" 6"
6"
1/ 2"
1/
2" 8"
SLATE
LOOKOUTS
LEAD PIPE SLEEVE
METAL LINED GUTTER
SCREEN
N
FINAL CONSTRUCTION DOCUMENTS
Af fa ir s
Ve te ra ns
Approved: Infection Control Officer
Approved: Safety Manager
Approved: GEMS Coordinator
Approved: Energy Engineer
Approved: Associate Director
Approved: Chief of Staff
Approved: Service Chief th re e inc he s = o ne fo ot on e an d on e-ha lf i nc he s = o ne fo ot on e inc h on e fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf i nc h on e fo ot th re e-eig ht s i nc h on e fo ot on e-qu ar te r i nc h on e fo ot on e-eig ht in ch o ne fo ot
DRAWING NO.
Dwg. Of
Project No.
Date
DrawnChecked
Location
Building Number
Project Title
Approved: Medical Center Director
Approved: Chief of Facility Management Svc.
Drawing Title
DateRevisions
BUILDING 5
VA MEDICAL CENTER, SALEM, VA 24153
REPLACE ROOF AND TUCKPOINT (BUILDING 5)
102 3rd Ave., NE Hickory, NC 28601
828.315.9962 www.atriaxgroup.com
2105 Water Ridge Pkwy #
Charlotte, NC 28217 704.535.6374 www.wmba.net
Quality Consulting Engineers, PLLC
6277-600 Carolina Commons Drive, #
Indian Land SC 29707 803.207.5450 djones@qualityconsultingengineers.com 12
1 2 3 4 5 6 7 8
A
B
C
D
E
F
658-16-101
C :\U se rs
\s c h ei ke la r d
\D oc u m en ts \3
8_
VA
S al em b ld g
R oo f R e p la ce m en t_ Ar c h _S ar a C he ik el ar d.
rv t
/2 0/
0:
:0
AM ROOFING DETAILS
22 OCTOBER 2018
22 OCTOBER 2018
AE301
Designer Checker
1 1/2" = 1'-0"D2 BASE FLASHING SECTION
3/4" = 1'-0"A2 DORMER SECTION
3/4" = 1'-0"B2 DORMER WINDOW SILL
3/4" = 1'-0"B4 EXISTING DORMER ELEVATION
1 1/2" = 1'-0"F2 RAKE FLASHING DETAIL
1 1/2" = 1'-0"A1 RAKE FLASHING SECTION
3/4" = 1'-0"D3 REGLET SECTION
1 1/2" = 1'-0"F6 TYP. BASE FLASHING DETAIL
1 1/2" = 1'-0"D4 TYP. COUNTERFLASHING DETAIL
3" = 1'-0"C2 DORMER SIDE WALL
3/4" = 1'-0"F4 EXISTING TYPICAL SECTION THROUGH CORNICE
FIELD SLATE 20" OR 24"
LENGTH BY 12" WIDTH
DORMER SLATE 16"
LENGTH BY 8" WIDTH
- 4
'-1 1"
+/- 3'-6 1/2"
C3
AE302
C3
AE302
F1
AE302
F4
AE302
ALL WOOD TRIM AROUND
LOUVERS IS TO BE REPLACED
WITH NEW TRIM TO MATCH
THE EXISTING.
ALL LOUVERS ON SLATE ROOFS
TO BE REPLACED W/ NEW
PREFINISHED ALUMINUM
LOUVERS. EXHAUST/INTAKE
DUCT WORK HAS BEEN
ATTACHED TO THE BACK OF THE
LOUVERS AT SOME LOCATIONS.
CONTRACTOR TO VERIFY
LOCATIONS PRIOR TO PROVIDING
BID.
FIELD SLATE 20" OR 24"
LENGTH BY 12" WIDTH
DORMER SLATE 16"
LENGTH BY 8" WIDTH
AE303
F4
TYP
B1
AE303
TYP
D4
AE303
TYP
D7
AE303
TYP
F1
AE303
TYP
C3
AE302
AE302
F1
AE302
F4
AE302
F6
ATTIC SLAB
112'-7"
1/2" COPPER HOOK DAM, FLATTEN
TO ALLOW SLATE TO LIE FLAT.
COPPER DORMER WALL FLASHING,
CONT. FULL HEIGHT OF LOUVER.
EXTEND TOP END BEHIND CROWN
MOLDING 1" MIN. INSTALL OVER
SELF-ADHERING UNDERLAYMENT.
SECURE INTO WOOD FRAMING W/
COPPER NAILS AT 4" O/C.
NEW CONT. #30 FELT UNDERLAYMENT.
INSTALL OVER SELF-ADHERING
UNDERLAYMENT IN ACCORDANCE
WITH THE PROJECT DOCUMENTS AND
SPECIFICATIONS. LAP ONTO STEP
FLASHING. SEE FOR
ADDITIONAL INFORMATION.
NEW CONT. SELF-ADHERING
UNDERLAYMENT. INSTALL ON VERTICAL
DORMER WALLS. LAP ONTO SELF-
ADHERING ROOF UNDERLAYMENT. SEE
FOR ADDITIONAL INFORMATION.
INSTALL NEW SLATE TO MATCH
EXISTING SLATE LAYOUT IN
ACCORDANCE WITH THE PROJECT
DOCUMENTS AND SPECIFICATIONS.
AT SOME LOUVER LOCATIONS MECHANCIAL
DUCT EXISTS IN THE ATTIC. AT THESE
LOCATIONS THE DUCT IS SECURED INTO THE
WOOD BLOCKING FROM THE INSIDE OF THE
DUCT. HOLES IN THE LOUVERS MUST BE
MADE TO ACCESS THE DUCT FASTENERS
AND A SECTION OF THE DUCT REMOVED IN
ORDER TO REMOVE THE LOUVER. PROVIDE
SUPPLEMENTAL WOOD BLOCKING IN THE
ATTIC SO DUCT CAN BE SECURED FROM THE
EXTERIOR WITH REINSTALLED.
INTERIOR
OF DUCT
NEW WOOD TRIM TO MATCH EXISTING
SIZE AND PROFILE. SECURE INTO
EXISTING RAFTERS W/ (2) S.S. TRIM
SCREWS AT EACH RAFTER.
/F1 AE303
/F1 AE303
SELF-ADHERING UNDERLAYMENT
ADHERE TO NEW PLYWOOD
LEVELING LAYER.
INSTALL SLATE STARTER
COURSE AT PERIMETER.
SLATE SHALL EXTEND
1-1/2" BEYOND
EXTERIOR FACE OF
WOOD TRIM/FASCIA AT
EAVE.
INSTALL NEW SLATE IN ACCORDANCE WITH
THE PROJECT DOCUMENTS AND
SPECIFICATIONS. SECURE W/ (2) COPPER
NAILS THROUGH EXISTING HOLES IN SLATE.
EXISTING WOOD FRAMING
EXISTING LOUVER. ALL LOUVERS ARE TO BE
REPLACED WITH NEW PREFINISHED ALUMINUM
TO MATCH EXISTING. AT SOME LOCATIONS
WINDOW IS PRESENT IN LIEU OF LOUVER.
CONT. SELF-ADHERING
UNDERLAYMENT FLASHING STRIP.
EXTEND ONTO SELF-ADHERING
UNDERLAYMENT AND COPPER
DRIP EDGE.
EXISTING T&G WOOD PLANK DECK.
SEE D1/AE305 FOR REPLACEMENT
OF DAMAGED SECTIONS OF DECK.
NEW CONT 1/2" PLYWOOD SHEATHING
LEVELING LAYER. SECURE W/ 8d NAILS
AT 8" O/C AT EACH ROOF JOIST.
NEW CONT. 1/4"x1 1/2" PRESSURE
TREATED CANT STRIP. SECURE THRU
COPPER FLASHING AND SELF-ADHERED
UNDERLAYMENT INTO DECK W/ #10
CTD. FLATHEAD SCREWS AT 12"O.C.
STAGGERED.
NEW 20 OZ. COPPER DRIP
EDGE. FABRICATE TO PROFILE
SHOWN. SECURE TO DECK W/
COPPER NAILS AT 6"O.C.
1 1 /2"
AE305
D5
NEW WOOD TRIM/FASCIA TO
MATCH EXISTING SIZE AND
PROFILE. SECURE INTO EXISTING
WOOD RAFTERS W/ TWO (2) S.S.
TRIM SCREWS AT EACH RAFTER.
INSTALL NEW SLATE TO MATCH EXISTING
SLATE IN ACCORDANCE WITH THE PROJECT
DOCUMENTS AND SPECIFICATIONS. SECURE
W/ (2) COPPER NAILS THROUGH EXISTING
HOLES IN ACCORDANCE W/ TYPICAL
FLASHING METHODS FOR SLATE.
EXISTING WOOD
FRAMING
EXISTING LOUVER TO BE REMOVED. ALL LOUVERS ARE TO
BE REPLACED WITH NEW PREFINISHED ALUMINUM LOUVERS
TO MATCH EXISTING. SEE ELEVATIONS FOR LOUVER
LOCATIONS.
EXISTING T&G WOOD PLANK
DECK. SEE D1/AE305 FOR
REPLACEMENT OF DAMAGED
SECTIONS OF DECK.
SELF-ADHERING UNDERLAYMENT ADHERE
TO NEW PLYWOOD LEVELING LAYER. TURN
UP WOOD FRAMING AND TERMINATE WITH
P.T. WOOD BLOCKING.
NEW CONT. 1/2" PLYWOOD SHEATHING
LEVELING LAYER. SECURE W/ 8d NAILS
AT 8" O/C AT EACH ROOF JOIST.
AT LOUVER
LOCATIONS INSTALL 20
OZ COPPER PAN W/
1/2" BACK DAM UNDER
WOOD NEW WOOD
SILL.
AE305
D5
AE302
F6
NEW PEEL AND STICK
TRACTION MEMBRANE
FOR INFORMATION NOT SHOWN SEE F4/AE302
EXISTING DRAIN PIPING EXISTS AT
SOME LOCATIONS.
PROVIDE FILLET BEADS OF SPECIFIED
SEALANT AROUND PIPE BEFORE AND
AFTER INSTALLATION OF COPPER
APRON FLASHING.
PROVIDE FILLET BEADS OF URETHANE
SEALANT AROUND PIPE AFTER
INSTALLATION OF SELF-ADHERING
UNDERLAYMENT.
NEW COPPER APRON FLASHING.
INSTALL AND SECURE INTO WOOD
BLOCKING W/ #12 S.S. SCREWS
THROUGH EPDM SEALING WASHERS.
NEW WOOD SILL TO MATCH EXISTING SIZE AND
PROFILE WHERE LOUVERS ARE TO BE REPLACED.
SECURE INTO WOOD FRAMING W/ (2) S.S. TRIM
SCREWS AT 12" O/C. CLEAN, PRIME AND PAINT.
SILL AT WINDOW LOCATIONS TO REMAIN.
NEW P.T. WOOD BLOCKING. SECURE THORUGH
SELF-ADHERING UNDERLAYMENT INTO WOOD
FRAMING W/ (2) ROUND #10 S.S. WOOD
SCREWS AT 12" O/C. LEAVE ROOM ABOVE
BLOCKING TO ALLOW FOR THE INSTALLATION
OF NEW COPPER APRON FLASHING.
NEW COPPER FLASHING CLEAT.
INSTALL AND SECURE BETWEEN
SLATE WITH COPPER NAILS.
INSTALL A CONT. BEAD OF APPROVED
SEALANT BETWEEN WOOD SILL AND
FLASHING.
AE305
D5
NEW METAL SILL PAN & END DAM PER LOUVER
MFGR RECOMMENDATIONS
NEW PEEL AND STICK TRACTION
MEMBRANE
N
FINAL CONSTRUCTION DOCUMENTS
Af fa ir s
Ve te ra ns
Approved: Infection Control Officer
Approved: Safety Manager
Approved: GEMS Coordinator
Approved: Energy Engineer
Approved: Associate Director
Approved: Chief of Staff
Approved: Service Chief th re e inc he s = o ne fo ot on e an d on e-ha lf i nc he s = o ne fo ot on e inc h on e fo ot th re e-qu ar te rs in ch o ne fo ot on e-ha lf i nc h on e fo ot th re e-eig ht s i nc h on e fo ot on e-qu ar te r i nc h on e fo ot on e-eig ht in ch o ne fo ot
DRAWING NO.
Dwg. Of
Project No.
Date
DrawnChecked
Location
Building Number
Project Title
Approved: Medical Center Director
Approved: Chief of Facility Management Svc.
Drawing Title
DateRevisions
BUILDING 5
VA MEDICAL CENTER, SALEM, VA 24153
REPLACE ROOF AND TUCKPOINT (BUILDING 5)
102 3rd Ave., NE Hickory, NC 28601
828.315.9962 www.atriaxgroup.com
2105 Water Ridge Pkwy #
Charlotte, NC 28217 704.535.6374 www.wmba.net
Quality Consulting Engineers, PLLC
6277-600 Carolina Commons Drive, #
Indian Land SC 29707 803.207.5450 djones@qualityconsultingengineers.com 12
1 2 3 4 5 6 7 8
A
B
C
D
E
F
658-16-101
C :\U se rs
\s c h ei ke la r d
\D oc u m en ts \3
8_
VA
S al em b ld g
R oo f R e p la ce m en t_ Ar c h _S ar a C he ik el ar d.
rv t
/2 0/
0:
:0
AM ROOFING DETAILS
22 OCTOBER 2018
22 OCTOBER 2018
AE302
Designer Checker
3/4" = 1'-0"C1 TYPICAL DORMER LOUVER ELEVATION
NTSC5 TYPICAL DORMER SIDE ELEVATION
3" = 1'-0"C3 PLAN - DORMER SIDE WALL
3" = 1'-0"F1 DORMER SECTION
3" = 1'-0"F4 DORMER LOUVER/WINDOW SILL
6" = 1'-0"F6 ENLARGED DORMER LOUVER/WINDOW SILL
EXISTING WOOD RAFTERS
2" LG. COPPER CLEAT SPACED AT 12"
O/C. ON BOTH SIDES OF VALLEY.
SECURE EACH CLEAT W/ (2) COPPER
NAILS. BEND BACK OF CLEAT TO
CONCEAL NAILS.
30" WIDE, 20 OZ. COPPER VALLEY
FLASHING. FABRICATE TO PROFILE
SHOWN. SECURE TO DECK W/
COPPER CLEATS EACH SIDE.
FIELD SLATE. FIELD CUT AS
REQUIRED. SECURE INTO DECK
W/ COPPER NAILS.
NOTE: DO NOT PENETRATE COPPER VALLEY
FLASHING W/ FASTENERS. ADD ADDITIONAL
HOLES IN SLATE OR USE COPPER TIE WIRE
TO…
This is the start of the file's text. The full file is on GovTribe.