36C24619R0051-0003001.pdf

PDF 1 MB Posted

Attached to
Upgrade Roofs and Tuckpoints (VA-19-00015851)
Solicitation number
36C24619R0051
Issued by

About this file

36C24619R0051 0003 20170905 Atriax-SVAMC Bld. 5 Roofs Limited Asbestos and Lead Based Paint Surveys.pdf

View the file

Other files

File Type Posted
36C24619R0051-0005001.pdf PDF
36C24619R0051-0005000.docx DOCX document
36C24619R0051-0004001.txt TXT text file
36C24619R0051-0004000.docx DOCX document
36C24619R0051-0003000.docx DOCX document
36C24619R0051-0002000.docx DOCX document
36C24619R0051-0001001.pdf PDF
36C24619R0051-0001000.docx DOCX document
36C24619R0051-001.xlsx XLSX spreadsheet
36C24619R0051-003.pdf PDF
36C24619R0051-002.pdf PDF
36C24619R0051-004.pdf PDF
36C24619R0051-000.docx DOCX document
36C24619R0051_2.docx DOCX document
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2524 LANGHORNE ROAD

LYNCHBURG, VA 24501

800-242-4906 TOLL FREE

434-847-7796 MAIN

434-847-0047 FAX

www.HandP.com

*ENGINEERING >> SURVEYING >> PLANNING

July 7, 2017

Atriax Group P.O. Box 1629 (28603) 102 3rd Avenue, NE Hickory,North Carolina28601

Attention: Bob Sinclair, Director of Operations

Email: bob.sinclair@atriax.com Phone: 828-315-9962

Subject: Limited Asbestos and Lead Based Paint Survey Services Building 5 Roof Sampling

Salem VA Medical Center-Salem, Virginia H&P Project: 20170905

Mr. Sinclair, Hurt & Proffitt, Inc. (H&P) has performed a limited survey of the accessible areas of the roof of Building 5 located at the Salem Veterans Administration Medical Center (SVAMC) Campus in Salem, Virginia. The survey was conducted to identify asbestos containing materials and lead-based painted building components prior to renovation work. The inspection was performed by H&P representative Ken Hundley (Va. Asbestos Inspector 3303 001516). The following represent H&P’s report for the above-referenced project.

1.0 Subject Site and Survey Description

The focus of this sampling event was the safely accessible areas of the roof of Building 5 as designated by the client. The roof system comprises slate shingles on the main building pitched roof and a small section of a flat built-up roof on the south west side. Due to safety and access limitations, H&P was unable to sample the steep sections of the slate roof; therefore, we have relied upon past experience from sampling similar roofs at the SVAMC complex in forming our conclusions and recommendations for the un-sampled areas. At the request of the client, H&P engaged the services of a roofing contractor to perform repairs of the sample locations. The survey was conducted on June 20, 2017.

2.0 Asbestos Sample Analysis Laboratory Analytical Results

The asbestos sampling included the collection and analysis of ten (10) individual samples/layers of suspect asbestos containing materials (ACM). The samples were submitted for analysis by EPA Method No. 600/R-93/116 Polarized Light Microscopy (PLM) to SanAir Technologies Laboratory in Powhatan, Virginia, a National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory licensed to perform asbestos bulk analysis within the Commonwealth of Virginia. The analytical results are presented below in Table 1. Copies of the laboratory reports and Chain-of- Custody forms are included as an attachment to this report. Note: The laboratory report includes the results of a sampling event consecutively performed at the Building 74-77 Corridor, the results of which are presented in a separate report.

mailto:bob.sinclair@atriax.com

Table 1: Asbestos Samples Analysis Results:

Sample Number Sample Location Material Type Lab Description Analytical Result

(Estimated % Asbestos)

Building 5 Roof

004-RFBLT-A

Flat Roof Field Tar Black Non-Fibrous None Detected

Flat Roof Field Felt Black Fibrous None Detected

Flat Roof Field Foam Yellow Non-Fibrous None Detected

005-RFFLH-A

Flat Roof

Penetration Flashing Black Non-Fibrous 3% Chrysotile

006-RC-A

Flat Roof Flashing at Brick Caulk/Sealant Grey Non-Fibrous 5% Chrysotile

006-RC-B

Flat Roof Flashing at Brick Caulk/Sealant Not Analyzed-Positive Stop

006-RC-C

Flat Roof Flashing at Brick Caulk/Sealant Not Analyzed-Positive Stop

007-RTC-A

Flat Roof Flashing at

Brick Caulk Tan Non-Fibrous None Detected

007-RTC-B

Flat Roof Flashing at

Brick Caulk Tan Non-Fibrous None Detected

007-RTC-C

Flat Roof Flashing at

Brick Caulk Tan Non-Fibrous None Detected

None Detected = No asbestos detected in sample during analysis Bold = Positive for Asbestos

3.0 Sample Analysis Results Discussion

From the results of the sample analysis, asbestos was identified at the subject site.

3.1 Flat Built-up Roof

Asbestos (3% Chrysotile) was identified in one representative sample (005-RFFLH-A) of roof flashing material. This material is classified as a Category I non-friable ACM. All similar roof flashing at penetrations should be considered to be an asbestos containing material. There is approximately 50 linear feet of this material.

Asbestos (5% Chrysotile) was identified in one representative sample (006-RC-A) of roof flashing caulk/sealant. This material is classified as a Category I non-friable ACM. All similar roof caulk/sealant should be considered to be an asbestos containing material. There is approximately 50 linear feet of this material.

3.2 Pitched Slate Roof

The Building 5 main roof comprises slate shingles. Due to safety and access limitations, H&P was unable to sample the slate roof; therefore, we have relied upon past experience from sampling similar roofs at the SVAMC complex in forming our conclusions and recommendations for the un-sampled areas.

From previous sampling of similar roofs, we presume that the following materials on the main Building 5 roof are positive for asbestos:

Caulking sealant on the dormer and roof ridge lines. This material is classified as a Category I non-friable ACM. All similar caulking sealant should be considered to be an asbestos containing material.

Caulking on parapet walls (where present) and presumed on any penetrations such as sewer vents, chimneys, hatches, etc. This material is classified as a Category I non-friable ACM. All similar caulking should be considered to be an asbestos containing material.

Caulking over nail heads on the roof slates. This material is classified as a Category I non-friable ACM. All similar caulking should be considered to be an asbestos containing material.

Any other materials encountered on the roof must be presumed as positive for asbestos unless sampled and proven otherwise. Therefore, during progress of the work, if roofing materials other than the caulking on ridge lines, parapet wall flashing, penetration flashing or nail heads is encountered it must be presumed as asbestos containing and treated as such unless, samples are collected by a license Asbestos Inspector and the materials are analyzed and found to be negative for asbestos.

4.0 Survey Limitations and Recommendations

H&P conducted sampling of the reasonably and safely accessible suspect asbestos containing materials (ACM) of the Building 5 Roof and the Building 74/77 Corridor Interior and Exterior at the Salem Veterans Administration Medical Center Campus based on our understanding of the project scope of work and in accordance with our proposal. During the conduct of this event, sampling was conducted in the areas we could reasonably access and collect samples without damaging structural or building material integrity; as such, other ACM materials or discrete patches or layers could be present in areas that were not accessible to us such as concealed beneath membranes, slates or shingles and various layers or that we did not encounter due to limitations of access or visibility.

Therefore, if materials are encountered that were not sampled during this survey, they should be presumed to be positive for asbestos unless analysis is conducted and they are shown to be negative.

Since the materials that have been identified as asbestos containing may be disturbed during renovation/demolition activities, it is recommended that they be removed by appropriately trained or licensed asbestos abatement workers in accordance with Virginia, EPA and OSHA regulations.

If work is performed that will impact suspect materials that have not been sampled, it is recommended that they be sampled by a Virginia licensed Asbestos Inspector prior to disturbance. We note that during demolition activities, it is not uncommon to reveal materials that were not accessible during the survey or their presence could not otherwise be known.

5.0 Applicable Regulations and Recommendations

Following are some applicable regulations pertaining to asbestos containing materials.

5.1 EPA/NESHAP Regulations for Asbestos Containing Materials

The U.S. Environmental Protection Agency promulgated the National Emission Standards for Hazardous Air Pollutants (NESHAP) [40 CFR Part 61], which addresses the application, removal, and disposal of asbestos-containing materials (ACM). Under NESHAP the following categories are defined for asbestos-containing materials:

Friable - When dry, can be crumbled, pulverized, or reduced to powder by hand pressure.

Non-friable - When dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

Category I Non-friable ACM - Packings, gaskets, resilient floor coverings, and asphalt roofing products containing more than 1% asbestos.

Category II Non-friable ACM – Any material, excluding Category I Non-friable ACM, which contains more than 1% asbestos.

Regulated Asbestos Containing Material (RACM) – One of the following:

1. Friable ACM

2. Category I Non-friable ACM that has become friable.

3. Category I Non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading.

4. Category II Non-friable ACM that has a high probability of becoming, or has become, friable by the forces expected to act on the material in the course of demolition or renovation operations.

Under NESHAP, the following actions are required:

1. Prior to the commencement of demolition or renovation activities, the building owner must inspect the affected facility or part of the facility where the demolition or renovation activities will occur for the presence of asbestos.

2. Remove all RACM from the facility before any activity begins that would break up, dislodge, or similarly disturb the material or preclude access for subsequent removal.

3. RACM need not be removed if:

a) It is Category I non-friable ACM that is not in poor condition.

b) It is on a facility component that is encased in concrete or other similar material and is adequately wet whenever exposed.

c) It was not accessible for testing and was therefore not discovered until after demolition began and because of the demolition the material cannot be safely removed.

d) It is Category II non-friable ACM and the probability is low that the material will become crumbled, pulverized, or reduced to powder during demolition.

Note: Based on our experience, we recommend that all ACM be removed prior to renovation or demolition due to the fact that disturbance can damage them, create potential exposure to workers and occupants and make them friable. This recommendation is made as a best practice to reduce potential exposure and limit liability.

5.2 OSHA

The Occupational Safety and Health Administration (OSHA) regulates employee exposure to asbestos under 29 CFR 1926.1101 and 29 CFR 1926.1001. Work associated with known or suspect asbestos containing materials (ACM), including trace (<1%) levels of asbestos, must be conducted according to these regulations in addition to the noted EPA regulations where applicable.

6.0 Limited Lead-Based Paint Survey Findings and Results

H&P performed a limited lead-based paint (LBP) survey of select building components. The survey methodology was performed in general accordance with the testing procedures detailed in the U.S.

Department of Housing and Urban Development (HUD) “Guidelines for the Evaluation and Control of Lead-Based Paint Hazard in Housing.” However, this was not a comprehensive surface-by-surface investigation for LBP, but rather a screening survey of major painted building components anticipated to be impacted by the renovation/demolition where the presence of lead-based paint is suspected.

Based on the nature of this survey, when one component tests positive for the presence of lead paint all similar painted components must be assumed to be positive, unless additional testing is performed.

6.1 Lead-Based Paint (LBP) Survey Methodology

H&P Industrial Hygienist, Mr. Ken Hundley, collected paint chip samples for analysis of lead. The sampling testing was conducted by scraping paint from building material surfaces and submitting samples to an accredited laboratory for analysis. The samples were submitted for analysis by test method SW846/M3050B/7000B to SanAir Technologies Laboratory in Powhatan, Virginia. The analytical results are presented below in Table 2. Copies of the laboratory reports and Chain-of- Custody forms are included as an attachment to this report. Note: The laboratory report includes the results of a sampling event consecutively performed at the Building 74-77 Corridor, the results of which are presented in a separate report.

6.2 Testing Results

A total of four (4) samples were collected and submitted. The samples that tested positive for lead are listed below in Table 2.

Table 2: Lead Based Paint Positive Testing Results

Sample Number

Location Substrate Color Sample Result

(PPM)

Sample Result (By

Weight)

L-01 Building 5 Exterior Trim White 242,103.1 24.2103%

L-02 Building 5 Flat Roof Metal Vent

Stack on Flat Roof

Orange 160.7 0.0161%

L-03 Building 5 Exterior Flashing Silver <81.5 <0.0081%

L-04 Building 5 Interior Access Walls Roof Hatch

Area Tan <90.3 <0.009%

6.3 Findings and Conclusions

Based on the results of testing, lead based paint as defined as containing more than 0.5% by weight was identified on the following building components of Building 5 Roof:

All white painted exterior trim, window casings, windows sashes and other similarly painted components.

Based on the results of analysis of the orange painted exterior metal vent components, lead based paint as defined as containing more than 0.5% by weight was not identified on the components on the flat roof section; however, while less than the level at which lead based paint is defined, we note that lead was detected above the laboratory method detection limit.

Based on the results of analysis of the silver painted exterior flashing and the tan painted interior access walls, lead was not detected above the laboratory method detection limit.

6.4 Applicable Regulations

6.4.1 OSHA Regulations for Lead-Based Paint

Any painted surface or material containing lead may contain sufficient concentrations of lead, which when disturbed, may generate lead dust greater than the “Action Level” concentration of 30 micrograms per cubic millimeter or greater than the “Permissible Exposure Limit” of 50 micrograms per cubic meter established by the OSHA “Lead Exposure in Construction Rule” (29 CFR 1926.62).

The OSHA standard gives no guidance on acceptable levels of lead in paint at which no exposure to airborne lead (above the action level) would be expected. Rather, OSHA defines airborne concentrations, and references specific types of work practices and operations from which a lead hazard may be generated (reference 29 CFR 1926.62, section d). Environmental and personnel monitoring should be conducted during any removal or demolition process (as appropriate) to determine actual personal exposure. This monitoring information can be used to determine the levels of personnel protection and environmental controls required for work involving specific removal/demolition processes on specific structures. Under OSHA requirements, the Contractor performing the work will be required to conduct this monitoring. It is important to note that environmental controls will vary dependent upon the content of lead in paint, the process used to remove it, duration of the work, and the amount of paint to be removed.

6.4.2 EPA Regulations for Lead-Based Paint

For disposal of construction/demolition debris that has LBP, the Environmental Protection Agency (EPA) requires that testing of lead content be performed to determine proper disposal. EPA regulations require that a generator of waste determine if that waste is hazardous by performing testing in accordance with the requirements of 40 CFR 261.11 or for wastes that may be RCRA hazardous (such as items with high lead content), the generator may assume that the waste is hazardous and comply with the hazardous waste regulation.

7.0 Qualifications and Limitations of the Asbestos and Lead Survey

This report summarizes our evaluation of the subject site based on our understanding of the requested scope of work as relayed to us. The findings prepared by H&P are based upon our observations and the analytical analysis of the samples collected at the time of our field inspection.

Additional ACM may exist (undetected and/or inaccessible) in other area not surveyed or otherwise identified during this assessment. Our recommendations are based on the guidelines presented by the EPA, Commonwealth of Virginia and OSHA. Any conditions discovered which deviate from the data contained in this report should be presented to us for our evaluation.

This report has been prepared for the exclusive use of our Client and/or their agents. This service was performed in accordance with generally accepted environmental practices. Our conclusions and recommendations are based, in part, upon information provided to us by others; we have not verified the completeness or accuracy of the information provided by others, unless otherwise noted.

During this study, suspect asbestos samples were submitted for analysis at an NVLAP-accredited laboratory via polarized light microscopy and suspect LBP was analyzed using industry standard methods and practices. As with any similar survey of this nature, actual conditions exist only at the precise locations from which samples were collected. Certain inferences are based on the results of this sampling and related testing to form a professional opinion of conditions in areas beyond those from which the samples were collected. It is also understood that this is a limited survey so that it is possible that concealed materials may be present that were not accessible to us. No other warranty, expressed or implied, is made.

Under this scope of services, H&P assumes no responsibility regarding response actions initiated as a result of these findings or liability for the duties and responsibilities of the Client or Building Owner with respect to compliance with applicable regulations. Compliance with regulations and response actions are the sole responsibility of the Client or Building Owner and should be conducted in accordance with local, state, and/or federal requirements and should be performed by appropriately qualified and licensed-personnel, as warranted.

Closing

Should you have any questions, please call Greg Whitt at (540) 521-1008 or via email at g.whitt@handp.com. Thank you for the opportunity to serve as your environmental consultant on this project.

Sincerely, HURT & PROFFITT, INC

Gregory L. Whitt Mary Beth Wriston Environmental/Industrial Hygiene Manager Environmental/Industrial Hygiene Senior Roanoke Office Roanoke Office

Attachments: Asbestos and Lead Laboratory Analysis Report and Chain-of-Custody mailto:g.whitt@handp.com

SanAir Technologies LaboratorySanAir Technologies Laboratory

Analysis Report prepared for

Hurt & Proffitt, Inc.

Report Date: 6/28/2017 Project Name: Bldg 77-74 - Bldg 5 Project #: 20170905-623 SanAir ID#: 17023610

804.897.1177 www.sanair.com804.897.1177 www.sanair.com

SanAir Technologies Laboratory, Inc.

1551 Oakbridge Drive, Suite B, Powhatan, VA 23139

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Hurt & Proffitt, Inc.

2524 Langhorne Road Lynchburg, VA 24501

June 28, 2017

SanAir ID # 17023610 Project Name: Bldg 77-74 - Bldg 5 Project Number: 20170905-623

Dear K Hundley, We at SanAir would like to thank you for the work you recently submitted. The 23 sample(s) were received on Friday, June 23, 2017 via FedEx. The final report(s) is enclosed for the following sample (s): 001-RFBLT-A, 001-RFBLT-B, 001-RFBLT-C, 002-RCLW-A, 002-RCLW-B, 002-RCLW-C, 003- RCLB-A, 003-RCLB-B, 003-RCLB-C, 004-RFBLT-A, 005-RFFLH-A, 006-RC-A, 006-RC-B, 006-RC- C, 007-RTC-A, 007-RTC-B, 007-RTC-C, 008-WLPL-A, 008-WLPL-B, 008-WLPL-C, 009-WGLZ-A, 009-WGLZ-B, 009-WGLZ-C.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

23 sample(s) in Good condition

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Hurt & Proffitt, Inc.

2524 Langhorne Road Lynchburg, VA 24501

Project Number:

P.O. Number:

Project Name:

20170905-623

Bldg 77-74 - Bldg 5

Collected Date:

Received Date:

Report Date:

Analyst:

6/20/2017

6/23/2017 10:50:00 AM

6/28/2017 2:29:15 PM

Pisula, Nicholas

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 001-RFBLT-A / 17023610-001 Black 100% Other None Detected Bldg 77-74 - Roof - Built Up, Non-Fibrous Membrane Homogeneous

001-RFBLT-A / 17023610-001 Brown 95% Cellulose 5% Other None Detected Bldg 77-74 - Roof - Built Up, Fibrous Insulation Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 001-RFBLT-B / 17023610-002 Black 100% Other None Detected Bldg 77-74 - Roof - Built Up, Non-Fibrous Membrane Homogeneous

001-RFBLT-B / 17023610-002 Brown 95% Cellulose 5% Other None Detected Bldg 77-74 - Roof - Built Up, Fibrous Insulation Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 001-RFBLT-C / 17023610-003 Black 100% Other None Detected Bldg 77-74 - Roof - Built Up, Non-Fibrous Membrane Homogeneous

001-RFBLT-C / 17023610-003 Brown 95% Cellulose 5% Other None Detected Bldg 77-74 - Roof - Built Up, Fibrous Insulation Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 002-RCLW-A / 17023610-004 White 100% Other None Detected Bldg 77-74 - Roof - Caulk Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 002-RCLW-B / 17023610-005 White 100% Other None Detected Bldg 77-74 - Roof - Caulk Non-Fibrous

Homogeneous

17023610 SanAir ID Number

FINAL REPORT

Certification

Analyst: Approved Signatory:

Analysis Date: 6/28/2017 Date: 6/28/2017 Page 3 of 8

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Hurt & Proffitt, Inc.

2524 Langhorne Road Lynchburg, VA 24501

Project Number:

P.O. Number:

Project Name:

20170905-623

Bldg 77-74 - Bldg 5

Collected Date:

Received Date:

Report Date:

Analyst:

6/20/2017

6/23/2017 10:50:00 AM

6/28/2017 2:29:15 PM

Pisula, Nicholas

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 002-RCLW-C / 17023610-006 White 100% Other None Detected Bldg 77-74 - Roof - Caulk Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 003-RCLB-A / 17023610-007 Black 96% Other 4% Chrysotile Bldg 77-74 - Roof - Caulk Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 003-RCLB-B / 17023610-008 Not Analyzed Bldg 77-74 - Roof - Caulk

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 003-RCLB-C / 17023610-009 Not Analyzed Bldg 77-74 - Roof - Caulk

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 004-RFBLT-A / 17023610-010 Black 100% Other None Detected Bldg 5 - Roof - Built-Up, Tar Non-Fibrous

Homogeneous

004-RFBLT-A / 17023610-010 Black 60% Cellulose 40% Other None Detected Bldg 5 - Roof - Built-Up, Felt Fibrous

Homogeneous

004-RFBLT-A / 17023610-010 Yellow 100% Other None Detected Bldg 5 - Roof - Built-Up, Foam Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 005-RFFLH-A / 17023610-011 Black 97% Other 3% Chrysotile Bldg 5 - Roof - Flashing Non-Fibrous

Homogeneous

17023610 SanAir ID Number

FINAL REPORT

Certification

Analysis Date: 6/28/2017 Date: 6/28/2017 Page 4 of 8

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Hurt & Proffitt, Inc.

2524 Langhorne Road Lynchburg, VA 24501

Project Number:

P.O. Number:

Project Name:

20170905-623

Bldg 77-74 - Bldg 5

Collected Date:

Received Date:

Report Date:

Analyst:

6/20/2017

6/23/2017 10:50:00 AM

6/28/2017 2:29:15 PM

Pisula, Nicholas

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 006-RC-A / 17023610-012 Grey 95% Other 5% Chrysotile Bldg 5 - Roof - Caulk/ Sealant Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 006-RC-B / 17023610-013 Not Analyzed Bldg 5 - Roof - Caulk/ Sealant

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 006-RC-C / 17023610-014 Not Analyzed Bldg 5 - Roof - Caulk/ Sealant

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 007-RTC-A / 17023610-015 Tan 100% Other None Detected Bldg 5 - Roof - Caulk Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 007-RTC-B / 17023610-016 Tan 100% Other None Detected Bldg 5 - Roof - Caulk Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 007-RTC-C / 17023610-017 Tan 100% Other None Detected Bldg 5 - Roof - Caulk Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 008-WLPL-A / 17023610-018 Brown 100% Other None Detected Bldg 77-74 - Wall Plaster/ Non-Fibrous Ceiling, Plaster Homogeneous

008-WLPL-A / 17023610-018 White 100% Other None Detected Bldg 77-74 - Wall Plaster/ Non-Fibrous Ceiling, Skim Coat Homogeneous

17023610 SanAir ID Number

FINAL REPORT

Certification

Analysis Date: 6/28/2017 Date: 6/28/2017 Page 5 of 8

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Hurt & Proffitt, Inc.

2524 Langhorne Road Lynchburg, VA 24501

Project Number:

P.O. Number:

Project Name:

20170905-623

Bldg 77-74 - Bldg 5

Collected Date:

Received Date:

Report Date:

Analyst:

6/20/2017

6/23/2017 10:50:00 AM

6/28/2017 2:29:15 PM

Pisula, Nicholas

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 008-WLPL-B / 17023610-019 Brown 100% Other None Detected Bldg 77-74 - Wall Plaster/ Non-Fibrous Ceiling, Plaster Homogeneous

008-WLPL-B / 17023610-019 White 100% Other None Detected Bldg 77-74 - Wall Plaster/ Non-Fibrous Ceiling, Skim Coat Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 008-WLPL-C / 17023610-020 Brown 100% Other None Detected Bldg 77-74 - Wall Plaster/ Non-Fibrous Ceiling, Plaster Homogeneous

008-WLPL-C / 17023610-020 White 100% Other None Detected Bldg 77-74 - Wall Plaster/ Non-Fibrous Ceiling, Skim Coat Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 009-WGLZ-A / 17023610-021 Grey 100% Other None Detected Bldg 77-74 - Window Glazing Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 009-WGLZ-B / 17023610-022 Grey 100% Other None Detected Bldg 77-74 - Window Glazing Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers 009-WGLZ-C / 17023610-023 Grey 100% Other None Detected Bldg 77-74 - Window Glazing Non-Fibrous

Homogeneous

17023610 SanAir ID Number

FINAL REPORT

Certification

Analysis Date: 6/28/2017 Date: 6/28/2017 Page 6 of 8

Disclaimer

The final report cannot be reproduced, except in full, without written authorization from SanAir.

Fibers smaller than 5 microns cannot be seen with this method due to scope limitations. The accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

For NY state samples, method EPA 600/M4-82-020 is performed.

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.

NY ELAP lab ID 11983

SanAir Technologies LaboratorySanAir Technologies Laboratory

Analysis Report prepared for

Hurt & Proffitt, Inc.

Report Date: 6/26/2017 Project Name: Bldg 77-74 Bldg 5 Project #: 20170905-624 SanAir ID#: 17023611

804.897.1177 www.sanair.com804.897.1177 www.sanair.com

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Hurt & Proffitt, Inc.

2524 Langhorne Road Lynchburg, VA 24501

June 26, 2017

SanAir ID # 17023611 Project Name: Bldg 77-74 Bldg 5 Project Number: 20170905-624

Dear K Hundley, We at SanAir would like to thank you for the work you recently submitted. The 6 sample(s) were received on Friday, June 23, 2017 via FedEx. The final report(s) is enclosed for the following sample (s): L-01, L-02, L-03, L-04, L-05, L-06.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Doug Peery Industrial Hygiene Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

6 sample(s) in Good condition

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Hurt & Proffitt, Inc.

2524 Langhorne Road Lynchburg, VA 24501

Project Number:

P.O. Number:

Project Name:

20170905-624

Bldg 77-74 Bldg 5

Collected Date:

Received Date:

Report Date:

Analyst:

6/20/2017

6/23/2017 10:50:00 AM

6/26/2017 4:28:54 PM

Peterson, Chelsea

Lead Paint Analysis Test Method: SW846/M3050B/7000B NOTE: µg/g=ppm Sample Description µg Pb Sample Calculated Sample Sample in Sample Size (grams) RL Result Result

17023611-001 L-01 / Bldg 5 - 37574 0.1552 64.4 242103.1 24.2103 % By Weightµg/g (ppm)

Exterior - Trim - White

Test Method: SW846/M3050B/7000B NOTE: µg/g=ppm Sample Description µg Pb Sample Calculated Sample Sample in Sample Size (grams) RL Result Result

17023611-002 L-02 / Bldg 5 - 26 0.1616 61.9 160.7 0.0161 % By Weightµg/g (ppm)

Exterior - Metal - Orange

Test Method: SW846/M3050B/7000B NOTE: µg/g=ppm Sample Description µg Pb Sample Calculated Sample Sample in Sample Size (grams) RL Result Result

17023611-003 L-03 / Bldg 5 - < 10 0.1227 81.5 <81.5 <0.0081 % By Weightµg/g (ppm)

Exterior - Flashing - Silver

Test Method: SW846/M3050B/7000B NOTE: µg/g=ppm Sample Description µg Pb Sample Calculated Sample Sample in Sample Size (grams) RL Result Result

17023611-004 L-04 / Bldg 5 - < 10 0.1108 90.3 <90.3 <0.009 % By Weightµg/g (ppm)

Interior - Access Walls - Tan

Test Method: SW846/M3050B/7000B NOTE: µg/g=ppm Sample Description µg Pb Sample Calculated Sample Sample in Sample Size (grams) RL Result Result

17023611-005 L-05 / Bldg 77-74 - 119 0.1743 57.4 684.9 0.0685 % By Weightµg/g (ppm)

Interior - Gray Windows/ Doors

17023611 SanAir ID Number

FINAL REPORT

Certification SanAir Technologies Laboratory, Inc. participates in the certification for environmental lead analysis programs as administered by AIHA-ELLAP (Lab ID 162952) and the State of New York-ELAP (Lab Id 11983), and has met the EPA's NLLAP program standards.

Signature: Reviewed:

Date: 6/26/2017 Date: 6/26/2017

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Hurt & Proffitt, Inc.

2524 Langhorne Road Lynchburg, VA 24501

Project Number:

P.O. Number:

Project Name:

20170905-624

Bldg 77-74 Bldg 5

Collected Date:

Received Date:

Report Date:

Analyst:

6/20/2017

6/23/2017 10:50:00 AM

6/26/2017 4:28:54 PM

Peterson, Chelsea

Paint Analysis Test Method: SW846/M3050B/7000B NOTE: µg/g=ppm Sample Description µg Pb Sample Calculated Sample Sample in Sample Size (grams) RL Result Result

17023611-006 L-06 / Bldg 77-74 - 88 0.1743 57.4 504.8 0.0505 % By Weightµg/g (ppm)

Interior - Tan Walls/ Ceiling

Method Reporting Limit <10 µg/0.1 g paint

17023611 SanAir ID Number

FINAL REPORT

Certification SanAir Technologies Laboratory, Inc. participates in the certification for environmental lead analysis programs as administered by AIHA-ELLAP (Lab ID 162952) and the State of New York-ELAP (Lab Id 11983), and has met the EPA's NLLAP program standards.

Signature: Reviewed:

Date: 6/26/2017 Date: 6/26/2017

Revision Date 04/21/2017

Disclaimer

Results relate only to the items tested

Results are not corrected for blanks

All quality control results are acceptable unless otherwise noted

SanAir Technologies Laboratory, Inc is not responsible for sample collection or interpretation made by others

This report does not constitute endorsement by AIHA/NVLAP and/or any other U.S. governmental Agencies; and may not be certified by every local, state or federal regulatory agencies

SanAir Technologies Laboratory, Inc only assures the precision and accuracy of the data it generates and assumes no responsibility for errors or biasing that occur during collection prior to SanAir’s receipt of the the sample.

SanAir’s Method Detection Limits (MDL) and Reporting Limits (RL) have been derived using wipe materials meeting ASTM-E1792. The MDL and RL may not be relevant or applicable for other forms of wipe materials.

Revision Date 04/21/2017

Lead Exposure Limits

Air

1.5 µg/m3 EPA National Ambient Air Quality Standard (Quality Time – Weight Average) 30 µg/m3 OSHA Action Level (8-hour time weighted average) 50 µg/m3 OSHA Permissible Exposure Limit (General Industry) 50 µg/m3 OSHA Permissible Exposure Limit (Construction)

Dust

10 µg/ft2 HUD Clearance Level for Floors 100 µg/ft2 HUD Clearance Level for Interior Window Sills 100 µg/ft2 HUD Clearance Level for Window Troughs 40 µg/ft2 HUD Clearance Level for Porch Floors

Water 15 ppb (µg/liter) EPA Maximum Containment Level

Paint 0.5% by weight HUD definition of lead based paint

1.0 mg/cm2 5000 ppm

Soil 400 ppm HUD-Play areas and high-contact areas for children

TCLP EPA Limits

5.0 mg/L Silver (Ag)

5.0 mg/L Arsenic (As) 100 mg/L Barium (Ba)

1.0 mg/L Cadmium (Cd)

5.0 mg/L Chromium (Cr)

0.2 mg/L Mercury (Hg)

5.0 mg/L Lead (Pb)

1.0 mg/L Selenium (Se)

File details come from the government source that posted it.