Text version
Norman, Keith A. NCO 6
From: John Johnson <jjohnson@valiantconstruct.com> Sent: Thursday, January 31, 2019 1:23 PM To: Norman, Keith A. NCO 6 Cc: Tim Holloman; Jim Erhart Subject: [EXTERNAL] RFI for Solicitation 36C24619B0001
Keith, See the following questions from our vendors:
1. Can you set-up another site visit for those Asbestos/Demo subs who couldn’t make the first site visit to look inside?
Door Hardware questions (Reference Spec 08 71 00 and Drawing AE711)
2. Hardware Set 3.1 shows an auto operator listed in the spec, but doesn't include it in Comments box on door schedule. Is there an active leaf auto opener for Set 3.1?
3. Door schedule shows “auto-openers” in Comments box for hardware Set 4 on four doors, but in specs, Set 4 calls for closers. Is it closers or auto operators? And if auto operators, is the finish a painted finish or clear anodize like Sets 3 and 3.1? If painted finish, do you have the color code?
Thanks, John Johnson
Senior Preconstruction Manager
VALIANT CONSTRUCTION LLC
O: 502.953.4492 | F: 502.305.6645 | C: 502.415.8991
4124 Wahl Street Boulevard | Louisville, KY 40218
Yes. - PBA
Set 4 includes closers. Disregard the 'auto-openers' in the schedule.
Add to set 4 the following:
1 Electric Hinge (A8112) LT-TA714 4-1/2" x 4-1/2" QC-12 US26D MK (Install at middle hinge) 1 ElectroLynx Harness QC-C1500P MK (Install between electric hinge and junction box) 1 Mortar Box MG-16 US2C MK 1 Electrified Lockset-Fail 63 64 SG NAC-82271 LNRGM x 630 SA Secure (U221/A156.13/F07)
24VDC
1 ElectroLynx Harness QC-CXXX x required length MK (Install between electric hinge and electrified lockset) 1 Card Reader Furnished and installed by security contractor OT 1 Power Supply AQD3 SU 1 Wiring Diagram WD-SYSPK YA Card reader to be used by authorized persons to gain entry from the push side of the opening Card reader to be used to unlock the push side lever of the electrified lockset Pull side lever of the electrified lockset always free for immediate egress
(PBA)