This is Amendment 5 to a Request for Quote (RFQ) for ceiling lift replacement services at the Washington DC Veterans Affairs Medical Center (VAMC). The amendment provides clarification on a specific technical requirement regarding Infection Control Risk Assessment (ICRA) protocols and containment procedures.
The RFQ seeks a complete fleet replacement solution for 282 ceiling lifts (276 standard motors and 6 bariatric motors) at the DC VAMC, with responses due by June 26, 2026 at 12:00 PM Eastern Time. Amendment 5 clarifies that ICRA carts and/or HEPA containment are required in all adaptable rooms, even when no above-ceiling access is necessary. Per the ICRA/PCRA team assessment, above-ceiling tiles will likely always be classified as Level 2 containment, while new installations and other areas can be Level 3 or 4 based on specific work requirements. The vendor must provide all labor, equipment, hardware, training, comprehensive drawings, electrical work, HVAC coordination, deinstallation, installation, one year of service, and at least a three-year warranty. All technical and implementation documents, certificates, manufacturer letters of authorization, and pricing responses in Excel/PDF format are mandatory for compliance. The Product Service Code is J065 (Medical Equipment), and the NAICS Code is 339112. The contracting office is located at 50 Irving Street NW, Washington DC 20422.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24526Q0269 AMD 4 RFQ.pdf | ||
| 36C24526Q0269_3.docx | DOCX document | |
| Drawings.zip | ZIP file | |
| 36C24526Q0269 0001.pdf | ||
| 36C24526Q0269_2.docx | DOCX document | |
| 36C24526Q0269 AM1.pdf | ||
| lift inv- AM1.xlsx | XLSX spreadsheet | |
| AL17-07 CEILING APPENDIX B.pdf | ||
| 36C24526Q0269 RFQ.pdf | ||
| 36C24526Q0269_1.docx | DOCX document | |
| CEILING PRICE LIST .xlsx | XLSX spreadsheet | |
| lift inv-.xlsx | XLSX spreadsheet | |
| AL14-07 Checklist APPENDIX A.pdf | ||
| AL14-07PSA Checklist APPENDIX C.pdf | ||
| RAIL PICTURE.jpg | JPG image |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Amendment to a Previous Combined Solicitation
Amendment to a Previous Combined Solicitation
| SUBJECT* |
| DC Ceiling Lift Replacement RFQ Ammendment 5 |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 20422 |
| SOLICITATION NUMBER* |
| 36C24526Q0269 |
| RESPONSE DATE/TIME/ZONE |
| 06-26-2026 12PM EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 10 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| J065 |
| NAICS CODE* |
| 339112 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Washington DC VAMC Contract Office 50 Irving St NW Washington DC 20422
POINT OF CONTACT*
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veterans Affairs |
washington DC VAMC per SOW
50 Irving St NW
Washington DC
| POSTAL CODE |
| 20422 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
The purpose of modification number 5 is to answer question.
Are ICRA carts and/or HEPA containment required in all adaptable rooms if no above-ceiling access is necessary?
Yes, per ICRA/PCRA team above ceiling tiles will likely always be level 2 and for the new installations/others can be 3 or 4 based on work requirements.