Attachment 3 P1 Drawing 27320-2 Access Notes 102025.pdf

PDF 445 KB Posted

Attached to
7A21--460-24-009 CLC and Fourth Floor Patient Elopement System
Solicitation number
36C24427R0001
Issued by

About this file

This document is a system architecture diagram and schematic for a hospital access control and security system integration project. The system is designed to manage card reader access points, maglocks, and alert notifications across multiple locations within a hospital facility, with the head end equipment centrally located within the coverage area.

The system requires procurement and installation of six Touchpad Exit Controllers (Model T80), six RB-8 Deactivation Relays, one 8-Zone Staff Alert Panel (SafePlace), one Proximity Card Reader, one Central Power Supply (Single Model T80), one Serial Terminal Server (DIGI), one RS-485 Hub, and one 16-Port Switch Box. The system will be hosted on a virtualized server running on hospital hardware and network infrastructure, with the client PC supplied and configured by the customer for enterprise use. Six new card readers are specified for integration, along with new maglocks (Lenel-1320 qty. 3, Lenel-1100 qty. 1, STP 8-Door qty. 1) and nine new door contacts. The design includes eight numbered locations throughout the facility, with specific access control and lock integration requirements at each location. Critical notes specify that RFT supplies power only to its own maglocks and provides integration relays; all final wiring, terminations, connection, and programming for integration with existing access control systems and maglocks supplied by others are the responsibility of the customer.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Virtualized Server

(on Hospital Hardware/Network)

NOTES:

1. For access control integration, we will provide a local relay at the door.

A cable (15’ in length) will be attached to the relay and coiled in the overhead above each door. Final connection and programming to be provided by others.

2. Door systems may integrate with existing maglocks that are supplied and maintained by others. Power to the existing maglocks is also supplied by others. RFT only supplies power to our own maglocks.

We provide a relay for integration. Final wiring and terminations provided by others.

8 Zone Wall Panel

STS

(DIGI)

1 2 3 4

1 2 3 4

5 6 7 8 9 10 11 12 13 14 15 16

16 PORT SWITCH

CPS 1

Head End Equipment

8 Zone Wall Panel

STS

(DIGI)

1 2 3 4

1 2 3 4

5 6 7 8 9 10 11 12 13 14 15 16

16 PORT SWITCH

��� 1

Head End Equipment

LOCATION TO BE DETERMINED

(Centrally located within the coverage area)

Staff Alert Panel 8-Zone SafePlace

EXIT

Central Power Supply���

Single Model T80 Touchpad Exit Controller (TEC) Qty. 6

Qty. 1

Qty. 1

Qty. 1

Qty. 1

Qty. 1

Patch Panel

Included in the 8 Zone Wall Panel

Serial Terminal Server

Qty. 1

Qty. 1

Qty. 1

Qty. 1

RS-485 Hub

16 Port Switch Box1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

16 PORT SWITCH

STS

(DIGI)

1 2 3 4

1 2 3 124 5 6 7 8 9 10 11

Proximity Card Reader (PC)PROX

READER

RB-8 Deactivation Relay Qty. 6RB-8

SD

X

CustomerCustomer

CLIENTCLIENT

Virtualized ServerV Client PC Supplied by Customer (configured for Enterprise)

Integrate with Access Control & Lock (by others)

SD

X

Integrate with Access Control & Lock (by others)

SD

X

Integrate with Access Control & Lock (by others)

SD

X

Integrate with Access Control & Lock (by others)

Integrate with Access Control & Lock (by others)

Integrate with Access Control & Lock (by others)

RB-8

RB-8

RB-8

RB-8

RB-8

RB-8

SafePlace

EXIT

PROX

READER

CustomerCustomer

CLIENTCLIENT

cmcnally Text Box Location 1 CR(E) Card Out ML(E) Maglock Always Locked Mon(N) Active Alarms to ACP cmcnally Text Box Location 2 CR(E) x2 Card In/Out ML(E) Maglock Always Locked cmcnally Text Box Location 3 CR(N) Card Out ML(E) Delayed Egress Maglock Locked on Schedule cmcnally Text Box Location 4 CR(N) Card Out ML(E) Delayed Egress Maglock Locked on Schedule cmcnally Text Box Location 5 CR(N) Card Out ML(E) Delayed Egress Maglock Always Locked cmcnally Ellipse cmcnally Ellipse cmcnally Callout Location 6 and 7 Demo existing?

CR(N) x2 ML(N) x2 cmcnally Callout

CLC 27

Head End Access and Wonder System

Emergency Power Required cmcnally Architect cmcnally Text Box cmcnally Architect cmcnally Text Box cmcnally Architect cmcnally Text Box cmcnally Architect cmcnally Text Box cmcnally Architect cmcnally Text Box cmcnally Architect cmcnally Text Box cmcnally Architect cmcnally Text Box cmcnally Architect cmcnally Text Box jadams Text Box

(N) New

(E) Existing Card Reader to Reset/Bypass Wander System Wander Alarms Report to Lenel Access System

(a) Tag in field door closed (Alarm to Lenel after 60-Seconds)

(b) Tag in field door opened (Alarm to Lenel instant) jadams Cloud jadams Text Box New Card Readers (6) New Mag locks (2) New EEB Pull (2) New Lenel-1320 (3) New Lenel-1100 (1) New LSP 8-Door (1) New Door Contacts (9)