561-26-104_3rd_Floor_Bathroom_MEP_Reference_Packet.pdf
PDF 5 MB Posted
- Solicitation number
- 36C24226R0128
About this file
This document is a Response to Request for Information (RFI) providing MEP (Mechanical, Electrical, Plumbing) reference drawings for Project 561-26-104, Repair OR Floor and Bathroom Leaks, focused on the 3rd Floor Men's H.C. Toilet Room 3-183 in Building 1.
The drawings provided are sourced from prior project 561-14-106, which renovated the same bathroom space, and represent the latest available MEP documentation. The document explicitly states that all drawings are for reference only and may not reflect current field conditions, with contractors required to field-verify all existing MEP conditions, dimensions, and system locations. The package includes architectural floor plans and interior elevations (pages 2-4); plumbing plans, riser diagrams, and general notes (pages 5-7); mechanical plans and notes (pages 8-9); electrical plans, general notes, and key notes (pages 10-12); and field-marked as-built plumbing documentation (page 13). Key architectural notes address interior finishes, tile work, window installations, radiator covers, wall construction, fire alarm devices, door operators, and wall-mounted accessories. Plumbing notes specify piping requirements, fixture installations, water closet and lavatory placements, floor drain provisions, and existing main preservation. Mechanical notes address HVAC ductwork coordination, dampers, supply/exhaust connections, temporary closures during construction, and asbestos precautions. Electrical notes detail lighting fixtures, unit heaters, switches, receptacles, fire alarm devices, door operators, nurse call systems, exhaust fans, and heating equipment. Contractors are responsible for preparing all required coordination and shop drawings in accordance with the Statement of Work and project specifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24226R0128 0004.pdf | ||
| Request for Information 561 26 104.docx | DOCX document | |
| 36C24226R0128 0003.docx | DOCX document | |
| 561-26-104_A104_Addendum1.pdf | ||
| 561-26-104_Tile_Room_Finish_Legend.pdf | ||
| 561-26-104_A102_Addendum1.pdf | ||
| 36C24226R0128 0002.docx | DOCX document | |
| 36C24226R0128 0001.docx | DOCX document | |
| Wage Determinations.pdf | ||
| FAR 52.225-2 BUY AMERICAN CERTIFICATE.docx | DOCX document | |
| Drawings - Project 561-26-104.pdf | ||
| Specifications - Project 561-26-104.pdf | ||
| 36C24226R0128_1.docx | DOCX document | |
| VAAR 852.219-75 LIMITATIONS ON SUBCONTRACTING CERTIFICATE.docx | DOCX document |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
561-26-104 REPAIR OR FLOOR AND BATHROOM LEAKS REFERENCE ONLY - CONTRACTOR TO FIELD VERIFY
MEP REFERENCE DRAWINGS - 3RD FLOOR BATHROOM
Response attachment to Request for Information No. 1 (MEP Drawings)
Excerpt - not to scale unless noted. Packet page 1
Project 561-26-104 Repair OR Floor and Bathroom Leaks
Notes
1. These drawings are from prior project 561-14-106, which renovated this bathroom. They are the latest and only MEP drawings available. The only as-built information available is the field-marked plumbing plan on packet page 13.
2. All drawings are for reference only and may not reflect current field conditions. The Contractor shall field-verify all existing MEP conditions, dimensions and system locations affecting the work, shall include all MEP modifications associated with the specified work, and shall prepare all required coordination and shop drawings in accordance with the
SOW.
3. The general notes and key notes shown are from the previous project. Not all of them, and possibly none, apply to this project; they are provided in case they are helpful. The SOW and project specifications govern. Sheets referenced within the excerpts are not part of this packet.
Contents Architectural - plan, interior elevations, notes p. 2-4 Plumbing - plan, risers, notes p. 5-7 Mechanical - plan, notes p. 8-9 Electrical - plan, notes p. 10-12 Field-Marked As-Built - Plumbing p. 13
ARCHITECTURAL - FLOOR PLAN
Excerpt - not to scale unless noted. Packet page 2
ARCHITECTURAL - INTERIOR ELEVATIONS
Excerpt - not to scale unless noted. Packet page 3
ARCHITECTURAL - NOTES
Excerpt - not to scale unless noted. Packet page 4
PLUMBING - PLAN
Excerpt - not to scale unless noted. Packet page 5
PLUMBING - RISER DIAGRAMS
Excerpt - not to scale unless noted. Packet page 6
PLUMBING - NOTES
Excerpt - not to scale unless noted. Packet page 7
MECHANICAL - PLAN
Excerpt - not to scale unless noted. Packet page 8
MECHANICAL - NOTES
Excerpt - not to scale unless noted. Packet page 9
ELECTRICAL - PLAN
Excerpt - not to scale unless noted. Packet page 10
ELECTRICAL - GENERAL NOTES
Excerpt - not to scale unless noted. Packet page 11
ELECTRICAL - KEY NOTES
Excerpt - not to scale unless noted. Packet page 12
FIELD-MARKED AS-BUILT - PLUMBING
Excerpt - not to scale unless noted. Packet page 13
File details come from the government source that posted it. Updated .