S06 M-121 Marked Up.pdf
PDF 675 KB Posted
- Solicitation number
- 36C24226B0027
About this file
This is a mechanical engineering drawing prepared by Miller-Remick LLC and LaBella Associates, DPC for a Veterans Affairs facility improvement project (Project No. 0499-0170). The document depicts mechanical new work plans for the 2nd and 3rd floors in Area E of what appears to be a Bronx medical center operating room and surgical preparation area expansion.
The drawings show the installation and routing of HVAC systems, including air handling units (AHU-14, AHU-16), chilled water coils, pre-filters, MPS preheat coils, and a fan array with variable frequency drives. Key equipment specifications include components such as 6-inch chilled water supply and return lines (CHS/CHR), 5-inch hot water piping (HPS/HPR), glycol accumulator units (GLY-ACCH-16), heat exchangers (HX-ACCH-16), and concrete pads for equipment mounting, with select equipment noting weights of 292 to 6,906 pounds. The plans utilize scales of 1/4 inch equals 1 foot and indicate both existing (E) and new (N) work, including connections from above and coordination between mechanical systems. The drawing is sealed by a Professional Engineer and includes general sheet notes regarding construction standards, symbols, and system requirements for the mechanical infrastructure supporting the renovated operating and surgical preparation rooms.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
A2
A7
B
B3
11 10.2 10 9.5
TELEPHONE CLOSET
2E-12
STAIR E
E
CORRIDOR
C2-42
STORAGE
2E-10
MECH
2E-11
CORRIDOR
C2-41
OR #7
2E-05P
CORRIDOR
C2-41A
SCRUB RM
2E-14
OR #6
2E-09
CORRIDOR
C2-41
(E)AHU-16
(E)EF-20
(E)52x24
(E)56x36 (E)40x40
(E )5
6x
M-302
(E )P
R E
-F
IL
T E
R S
(E )M
P S
P R
E H
E A
T C
O
IL
(N )C
H
IL
LE
D
W A
T E
R C
O
IL
(E )C
LE
A
N L
P S
H U
M
ID
. C O
IL
(N )F
A N
A R
R A
Y
D
IR
E C
T D
R
IV
E
(E)BAS
(E)BAS
(N)SF-VFD (TYP 2) (E)132x88
6'-0" AFF
(E)4" MPS
(E)2" MPR
EA FROM ABOVE
FROM ABOVE
UP
(E)CUH
R
(N)6" CHS
(N)6" CHR (E)5" CHR UP/DN
(E)5" CHS UP/DN
(E)5" HPR
(E)2" V
(E)4" MPS
(E)2" MPR
(E)5" MPS
(E)5" HPS
(E)3" V (E)2" DCW
(E)OA LOUVER
(E)EF-21
(ABOVE)
(E)CSG
(N)CC-AHU-16
(N)6" CHS
(N)6" CHR
A7
B
B3
11 10.2 10 9.5
M-302
(6,906 LB)
(N)6" GCS
(E)AHU-14 MECH
(3E-63)
ET-AHU-16
AS-AHU-16
GLY-ACCH-16
(N)4"
CONC.
PAD
(N)4"
CONC.
PAD
(N)3/4" DCW UP
(N)6" CHR UP
(E)CSG
BCF-AHU-16
BCF-ACCH-16
(E)3" V UP
(E)6" V UP
(E)2 1/2" V UP
(N)6" CHR
(N)6" GCS
FROM ABOVE
CHWP-16C/D
(N)6" CHS
(N)6" CHS
HX-ACCH-16
(E)5" CHS UP
(E)5" CHR UP
(E)2" MPR UP
(N)3/4" DCW
(N)1" CHS
(292 LB)
(564 LB)
(990 LB)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
CONSULTANTS
321 4 5 6 7 8 9 10
NO. DESCRIPTION DATE
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER
o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PLAN
NORTH
KEYPLAN
ACTUAL
NORTH
ENGINEER OF RECORD
M-R PROJECT NO:
Architect:
LABELLA ASSOCIATES, DPC
AREA E
C U s e rs
\m k e n n e d y \D o c u m e n ts
\0 -0
-B ro n x I m p ro v e O
R
S P
D -M
E P
-R M
K e n n e d y E
Z P
Y .r v t
/2
/2
:5 :1
A
M
M-121
MECHANICAL
NEW WORK PLAN
2ND & 3RD FLOOR - AREA E
IMPROVE OR & SPD HVAC (A/E) 526-23-133
Project Director
2025-09-23 LPM MBK
BID DOCUMENTS
FULLY SPRINKLERED
JAMES J. PETERS VA MEDICAL CENTER
BRONX, NEW YORK
0499-0170
SCALE: 1/4" = 1'-0"2 NEW WORK PLAN - 2ND FLOOR - AREA E
GENERAL SHEET NOTES:
1. REFER TO DRAWING M-001 AND M-002 FOR ABBREVIATIONS, SYMBOLS, AND
GENERAL NOTES.
2. SCHEDULING AND PHASING OF ALL WORK SHALL BE COORDINATED WITH THE VA
COR DURING UNOCCUPIED HOURS UNLESS STRICTLY EXPRESSED OTHERWISE.
O.R. SCHEDULED CONSTRUCTION AND ANY POSSBILE AHU DOWNTIME MUST BE
COORDINATED MINIMUM 2 WEEKS IN ADVANCE.
3. EXISTING AIR HANDLING UNIT (E)AHU-16 AND EXHAUST FAN (E)EF-20 SHALL BE
REBALANCED TO SERVE O.R. SUITE SPACES OUTSIDE OF PROJECT BOUNDARY.
ALL SUPPLY AND EXHAUST DUCTWORK REQUIRED FOR TEMPORARY REMOVAL
AND RECONNECTION TO SERVE EXISTING SPACES SHALL BE REINSTALLED AND
REBALANCED TO EXISTING AIRFLOWS PRIOR TO OCCUPANCY. REFER TO O.R.
ROOM AIR BALANCE SCHEDULE ON DRAWING M-702 AND AHU-16 CONTROLS
DIAGRAM ON DRAWING M-802 FOR ADDITIONAL INFORMATION.
SHEET KEYNOTES:
1 PROVIDE INDICATED EQUIPMENT HOUSEKEEPING PAD WITH 4" HI-VISIBLE SPILL
BERM AROUND PERIMETER FOR GYLCOL RETENTION. REFER TO STRUCTURAL
DETAIL FOR ADDITIONAL INFORMATION.
2 PROVIDE NEW 10-ROW STACKED CHILLED WATER COOLING COIL WITH ALL
APPURTENANCES PER MECHANICAL DETAILS. INTEGRATE VALVE AND SENSORS
WITH BAS. EXTEND NEW CONDENSATE PIPING TO EXISTING FLOOR DRAIN.
3 PROVIDE NEW 2x2 DIRECT DRIVE PLENUM FAN ARRAY WITH (2) VFD CONTROLLERS.
REFER TO MECHANICAL SCHEDULE FOR ADDITIONAL DETAILS.
4 PROVIDE NEW GYLCOL STORAGE FILL TANK WITH INTEGRATED PUMP AND GLYCOL
LOOP BYPASS CHEMICAL SHOT FEEDER THIS LOCATION. GLYCOL AND NON-GLYCOL
MAKEUP SHALL BE SOURCED FROM CLEAN STEAM GENERATOR SOFTENED COLD
WATER SUPPLY LINE WITHIN MECH ROOM.
5 EXTEND NEW 3/4" ROOF HYDRANT PIPING FROM EXISTING DOMESTIC COLD WATER
MAIN SUPPLYING EXISTING CLEAN STEAM GENERATOR MAKEUP. PROVIDE BRANCH
CONNECTION WITH COMBINATION FILL VALVE AND BACKFLOW PREVENTER. BOD:
WATTS SERIES 911 OR EQUAL.
6 PROVIDE (4) 24 VAC 2-WAY MODULATING CONTROL VALVES WITH NEMA 4X
ENCLOSURE AND HAND WHEEL. BOD: BRAY F7125 / F7150 OR EQUAL. PROVIDE NEMA
3R VALVE POWER PANEL WITH 120 / 24 VAC TRANSFORMERS. REFER TO M-800
CONTROLS SERIES DWGS FOR ADDITIONAL DETAILS.
7 PROVIDE NEW 6" CHS/R PIPE PENETRATIONS SPACED 18" O.C. DOWN THRU FLOOR.
UTLIZE NON-DESTRUCTIVE BAR DETECTION METHOD TO LOCATE AND AVOID
CUTTING/DRILLING ANY EXISTING SLAB REINFORCEMENT.
8 PROVIDE NEW NORMALLY CLOSED 2-WAY AUTOMATIC CONTROL VALVE AND PIPE TO
EXISTING CENTRAL PLANT CHILLED WATER.
SCALE: 1/4" = 1'-0"1 NEW WORK PLAN - 3RD FLOOR - AREA E
VHABRXNgD2 Rectangle
VHABRXNgD2 Rectangle
VHABRXNgD2 Rectangle
VHABRXNgD2 Rectangle
VHABRXNgD2 Rectangle
VHABRXNgD2 Rectangle
VHABRXNgD2 Rectangle
VHABRXNgD2 Line
VHABRXNgD2 Typewritten Text
(E)WF-12
VHABRXNgD2 Rectangle
VHABRXNgD2 Rectangle
VHABRXNgD2 Rectangle
VHABRXNgD2 Rectangle
VHABRXNgD2 Rectangle
File details come from the government source that posted it. Updated .