PreBid RFIs pt 3.pdf
PDF 239 KB Posted
- Attached to
- Z1DA--528A5-24-510 REPLACE EXTERIOR DOORS FINGER LAKES CANANDAIGUA, NY / BATH NY VA MEDICAL CENTERS
- Solicitation number
- 36C24224B0035
About this file
This document is a set of pre-bid Request for Information (RFIs) received from contractors regarding Solicitation 36C24224B0035 for the replacement of exterior doors at the Finger Lakes VA Medical Centers in Canandaigua, NY and Bath, NY.
The key details are:
- The solicitation is for the removal and replacement of approximately 76 exterior doors and door systems, including the restoration of some historical wood doors.
- The work will be performed at the Canandaigua, NY and Bath, NY VA Medical Centers.
- The procurement is set aside 100% for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS 236220 with a size standard of $45M.
- The estimated magnitude of the project is between $500,000 and $1,000,000.
- Bid bonding will be required.
- The solicitation materials will be available electronically on SAM.gov on or about July 3, 2024.
- The contract is anticipated to be awarded around August 2024.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24224B0035 0003.docx | DOCX document | |
| 36C24224B0035 0002.docx | DOCX document | |
| PreBid RFIs pt 2.docx | DOCX document | |
| 36C24224B0035 0001.docx | DOCX document | |
| PRE BID SITE VISIT 7-16-24 EXERIOR DOORS.pdf | ||
| EXTERIOR DOORS PROJECT RFIs.docx | DOCX document | |
| 24-510_Exterior Door FLHCS_Construction Documents.pdf | ||
| P07 - WAGE DETERMINATION - BATH.pdf | ||
| 36C24224B0035_1.docx | DOCX document | |
| 24-510_Exterior Door FLHCS_Specs.pdf | ||
| P07 - WAGE DETERMINATION - CANANDAIGUA.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
528A5-24-510 Replace Exterior Doors FLHCS
Pre-Bid RFIs
The following pre-bid RFIs were received by contractors in regards to the project titled above. VA responses are provided and shall be included within the scope and general understanding of this contract.
1. The glass is not clearly called out in the spec. A101 refers to Impact Glass (No Impact Framing is called out). GL-1 and GL-2 is called out, but the spec does not clearly state what it is.
Response: On drawing A101, the glazing types are labeled as insulated, low e, impact safety rated. The difference between the 2 is that GL-2 contains integral muntins. The specifications provide the make-up for an insulated glazing unit with low e coatings and other qualities.
For reference only: Impact safety rated in this case refers to the glazing being tempered;
heat strengthen glass rather than standard float glass. This glass typically breaks at a higher force and does so into fine pieces that reduce risk of injury.