S02-FINAL DRAWINGS 2 OF 2.pdf
PDF 44 MB Posted
- Attached to
- Y1DA--528A8-16-807 REPAIR PARKING LOTS
- Solicitation number
- 36C24222R0102
About this file
This document provides details on a federal contract opportunity from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2. The solicitation number is 36C24222R0102 for repair work on parking lots named "Y1DA--528A8-16-807 REPAIR PARKING LOTS." The related file is the final drawing set 2 of 2 as an amendment. The opportunity type is a solicitation for repairing parking lots at a Veterans Affairs facility. No further information is provided on response dates, award amounts, or other contractual requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24222R0102 0002.docx | DOCX document | |
| 36C24222R0102 0001.docx | DOCX document | |
| S02-FINAL DRAWINGS 1 of 2.pdf | ||
| EXHIBIT A - Past Performance Relevancy Questionnaire.docx | DOCX document | |
| FAR 52.225-2 Buy American Certification.docx | DOCX document | |
| EXHIBIT C - Past Performance Questionnaire.docx | DOCX document | |
| Divisional cost break down template.docx | DOCX document | |
| 36C24222R0102_1.docx | DOCX document | |
| Q and A.docx | DOCX document | |
| VAAR 819 219 77 VA Notice of Limitation on subcontracting.docx | DOCX document | |
| VS11-Boring Report-VA.pdf | ||
| EXHIBIT B - Sample Transmittal Letter for Past Performance Evaluation Questionnaire.docx | DOCX document | |
| Wage Determinations 8.5.2022.pdf | ||
| 528A8-16-807_Specifications.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
16 CALL BOX MOUNTING18 UNDERGROUND HANDHOLE - GRASS AREA
NTS
6"
6"
17 TYPICAL ELECTRICAL/COMMUNICATIONS
TRENCH DETAILNTS
6" M
IN
" M
IN
3'- 0"
C
OV
ER
(2
'-0 " M
IN
LINE SIDES OF EXCAVATION
WITH MIRAFI HP270 GEOTEXTILE
OR APPROVED EQUIVALENT
PULLBOX
(SEE SPECIFICATION 26 05 33)
FIBERCRETE COVER
GRADE, FEATHER & HAND TAMP
BACKFILL TO CREATE FLUSH
INSTALLATION AND POSITIVE
DRAINAGE AWAY FROM BOX
PREFABRICATED FIBERCRETE
HANDHOLE (PEDESTRIAN RATED)
4" MIN. TOPSOIL OR ASPHALT
PAVING (PER PAVEMENT SECTION)
TO MATCH SURROUNDING SURFACE.
BACKFILL ABOVE BEDDING MATERIAL SHALL BE
COMPACTED TO 95% OF ASTM D698 MAXIMUM
DENSITY UNLESS OTHERWISE NOTED TO BE
COMPACTED IN MAXIMUM 6" LIFTS. IN PAVEMENT
AREAS, BACKFILL MATERIAL SHALL BE TYPE 2
STONE SUBBASE AND SHALL BE COMPACTED TO
95% OF ASTM D1557 MAXIMUM DENSITY, PER
PAVEMENT SECTION.
METALLIC WARNING TAPE WITH
TRACER WIRE (ELECTRIC-RED;
COMMUNICATIONS-ORANGE)
CONDUIT AS
PER LIGHTING
PLAN
BEDDING MATERIAL SHALL BE
CLEAN SAND ENCASEMENT
IN 6" LAYERS COMPACTED TO 95%
OF ASTM D698 MAXIMUM DENSITY
UNLESS OTHERWISE NOTED
Christopher W. Geary PE# 099085
Albany Stratton VAMC Albany, NY 12208
528A8-16-807
CH
RI
ST
OPHER WILLIAM GEARY
099085
S
T A T E OF NEW Y O
R K
L IC
ENSED PROFESSIONAL ENG
IN
EE
R
ARCHITECT/ENGINEER OF RECORDCONSULTANT
Revisions: Date: 1/19/2021 Witczak Geary
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Dwg. of
Drawing Title
Approved:
Phase
Project Director
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
FOR TRENCH WIDTHS EXCEEDING 4' [1219mm] REFER TO TYPE 2 UTILITY TRENCH PATCH.
2" [50mm] MINIMUM OR THICKNESS OF EXISTING PAVEMENT WHICHEVER IS GREATER.
HOT MIX ASPHALT, PER PAVEMENT SECTION DETAIL
4" [100mm] MINIMUM THICKNESS OF EXISTING GRANULAR BASE COURSE MATERIALS, OR PER
PAVEMENT SECTION DETAIL, WHICHEVER IS GREATER.
TYPICAL UTILITY TRENCH PATCH23
4'-0" MAX.
[1219mm]
1'-0" MAX.
[305mm]
1'-0" MAX.
[305mm]
TRENCH
BACKFILL
ASPHALT
SAW CUT EXISTING.
ASPHALT FULL DEPTH BOTH
SIDES
TACK COAT (TYP.)
EXISTING PAVEMENT
GENERAL NOTES:
1. INTENT OF DETAIL IS TO SHOW WIDTHS AND MATERIAL FOR STANDARD UTILITY TRENCH
OPENINGS AND PATCHES. ANY DETAIL LISTED FOR A SPECIFIC UTILITY SHALL BE UTILIZED IN
CONJUCTION WITH THIS TYPICAL DETAIL.
2. MATERIAL AND COMPACTION REQUIREMENTS FOR PIPE BEDDING/SHADING SHALL BE IN
ACCORDANCE WITH THE SPECIFICATIONS FOR THE APPLICABLE UTILITY PIPE.
3. TRENCH BACKFILL SHALL COMMENCE 1 FOOT [305mm] ABOVE THE TOP OF PIPE. BACKFILL
COMPACTION SHALL BE PER SECTION 31 20 00 OF THE SPECIFICATIONS.
4. SURFACE REPAIR SHALL BE IN ACCORDANCE WITH THE APPROPRIATE SECTION OF THE
SPECIFICATIONS. ASPHALT SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION
32 12 16.
5. ALL DEPTHS SHOWN ARE AFTER BEING FULLY COMPACTED.
STONE SUBBASE
NTS
SOURCE: VA STANDARD DETAIL NOs. SD321216-02, 03 (MODIFIED)
6"
GALVANIZED
STEEL COVER
(H-20 RATED)
PREFABRICATED HEAVY TRAFFIC
HANDHOLE (H-20 RATED)
18"
19 UNDERGROUND HANDHOLE - VEHICULAR AREA
NTS
NOTES:
1. ALL DEPTHS SHOWN ARE AFTER BEING FULLY COMPACTED.
2. MINIMUM ELECTRICAL TRENCH COVER SHALL BE NO LESS THAN 24" (NEC TABLE 300.5
MINIMUM COVER REQUIREMENTS, 0-1000V)
3. WHERE UTILITY IS LOCATED WITHIN AREA OF PAVEMENT, THE CONDUIT SHALL BE A MINIMUM
OF 3' DEEP AND THE WARNING TAPE SHALL BE LOCATED BENEATH ANY SEPARATION FABRIC.
MAINTAIN A 12" MINIMUM SEPARATION BETWEEN CONDUITS AND WARNING TAPE. ADJUST
DEPTH OF CONDUIT AS NECESSARY, TO MAINTAIN MINIMUM DEPTH AND SEPARATION.
MIRAFI RS280i GEOTEXTILE
SEPARATION FABRIC OR
APPROVED EQUAL
20 LIGHT POST DETAIL
NTS
NOTES:
1. 4,000 PSI MIN 28 DAY COMPRESSIVE STRENGTH CONCRETE WITH GRADE 60
REINFORCING STEEL (GALVANIZED)
2. EXPOSED CONCRETE AND GROUT MAY BE STAINED. IF APPLICABLE, COLOR
TYPE IS TO BE SELECTED BY THE COR.
3. RUN TRACER WIRE ATTACHED TO EACH CONDUIT INTO THE POLE BASE.
PROVIDE MACHINE PRINTED CIRCUIT LABELS FOR CIRCUITS.
4. ALL DEPTHS SHOWN ARE AFTER BEING FULLY COMPACTED.
NYSDOT TYPE 2 STONE COMPACTED
TO 95% OF ASTM D698 MAXIMUM
DENSITY UNLESS OTHERWISE
NOTED COMPACTED IN MAX. 6' LIFTS
CAST-IN-PLACE OR PRECAST
CONCRETE FOOTER
1.25" MIN. RGS CONDUIT
(4)GALVANIZED#5x3'-6"
LONG BARS EQUALLY
SPACED
INSTALLATION IN CONCRETE REQUIRES
CONTINUOUS 12" EXPANSION JOINT
MATERIAL ALL AROUND. SEAL WITH
JOINT SEALER PER SPECIFICATIONS. USE
BITUMINOUS SEAL WHEN LOCATED IN AN
ASPHALT PAVED AREA.
SET BASE 30" ABOVE FINISHED GRADE,
WITH A SMOOTH RUB FINISH. 34" CHAMFER
EDGE, UNLESS BASE IS LOCATED IN
PARKING LOTS THEN SET BASE AT 4'
ABOVE FINISHED GRADE.
LIGHT POST BASE TO CONCRETE FOOTER
WITH 4 BOLT ANCHOR BASE.
24" [0.6m]
3" [0.1m]
3" [0.1m]
2.0 0'
[0.
6m
7.0 0'
MI
N.
[1.
8m
0.5
[0.
2m ] 6"±
[0.2m]
GROUNDING ROD 34" DIA. x 10'-0"
LONG, ENCASED IN PVC 2'-0" BELOW
FINISHED GRADE
#3x18" SQUARE TIES WITH 1.5' LAP
(TYP.) ON 20" VERTICAL SPACING
REFER TO
GROUNDING
ROD DETAIL
RGS TO PVC ADAPTER.
UNDERGROUND CONDUIT
SHALL BE PVC
NYSDOT TYPE 1 STONE
COMPACTED TO 95% OF ASTM D698
MAXIMUM DENSITY UNLESS
OTHERWISE NOTED
TRENCH
BACKFILL
TACK COAT (TYP.)
EXISTING PAVEMENT
ASPHALT
SAW CUT EXISTING.
ASPHALT FULL DEPTH
BOTH SIDES
GRANULAR
MATERIAL
> 4'-0" [1219mm]
TYPE 2 UTILITY TRENCH PATCHTYPE 1 UTILITY TRENCH PATCH
NOTES:
1. PULL SUPPLY AND LIGHT WIRING OUT DRILLED HOLE AND INTO CALL BOX VIA KNOCKOUT. ATTACH CALLBOX TO POLE WITH SELF-DRILLING
SCREWS AND NEOPRENE BONDED WASHERS AS SHOWN.
2. USE A NEOPRENE BONDED WASHER.
3. CALL BOX DOOR SHOWN REMOVED FOR CLARITY.
4. DO NOT DRILL HOLES IN THE TOP OR SIDES OF THE CALLBOX.
5. MOUNT SALVAGED CALL BOXES ON LIGHT POLES WHERE SHOWN ON PLANS.
A MIN. 4" SQUARE CORNERED POLE IS TO BE USED
TO ACCOMODATE THIS STANDARD INSTRUCTION
CALL BOX ANTENNA
NEOPRENE-BONDED GALV. STEEL
SEALING WASHER FOR 14" SCREW 4
PLACES SEE NOTES 2 & 3
8" HOLE DRILLED IN POLE FOR SUPPLY &
LIGHT WIRING. INSERT A GROMMET TO
PROTECT WIRING.
1/4 -14 X 1 1/4" LONG HEX WASHER HEAD
STAINLESS STEEL SELF DRILLING SCREW - 4
PLACES (SEE NOTE 1).
RESTORATION - OPEN AREAS22 NTS
MINIMUM 6" OF TOPSOIL
VA
RI
ES
SEEDED
AREA
C
OF
PIPE
L
FOR REQUIREMENTS OF SEED MIXTURE
AND APPLICATION SEE SPECIFICATIONS.
IMPORTED BEDDING MATERIAL
PER SPECIFICATIONS PLACED
IN 6" LAYERS AND COMPACTED.
PIPE
SEE NOTE 3
VARIES
LIM
IT
S
OF
B
AC
KF
ILL
VARIES
NOTES:
1. THIS RESTORATION WILL BE REQUIRED ON ALL DISTURBED AREAS THAT WILL NOT BE
COVERED WITH SOD OR OTHER SURFACING.
2. ROCKS LARGER THAN 2" CANNOT BE PLACED WITHIN TOPSOIL.
3. BACKFILL ABOVE BEDDING MATERIAL SHALL BE COMPACTED TO (85% TOP 16" AND 90%
BELOW 16") OF OPTIMUM DENSITY AS DETERMINED BY ASTM D698 COMPACTED IN MIN. 6"
LIFTS.
STORMWATER TRENCH DETAIL21 NTS
EXCAVATED
MATERIAL
VERTICAL TRENCH WALLS WITH
SHORING TO CONFORM TO O.S.H.A.
REGULATIONS **
24"
MIN.MIN.
12"
IMPORTED ADDITIONAL
BEDDING MATERIAL WHERE
SOFT OR UNSTABLE MATERIAL
HAS BEEN REMOVED
BACKSLOPE AS SPECIFIED
TO CONFORM TO O.S.H.A.
REGULATIONS **
PE
R
O.
S.
H.
A.
R
EG
UL
AT
IO
NS
MIN. TRENCH WIDTH
= 3.5 FT.
TRENCH WIDTH
SUBGRADE OR
GROUND
SURFACE
CURB & GUTTER OR
EXISTING EDGE OF
PAVEMENT
RESTORATION AS
SHOWN ON PLAN
NOTES:
IMPORTED BEDDING MATERIAL PER
SPECIFICATIONS PLACED IN 6"
LAYERS AND COMPACTED
UNDISTURBED SUBGRADE
(TYP.)
6" MIN.
6" MIN.
WHERE TRENCH PASSES THROUGH EXISTING PAVEMENT, THE PAVEMENT SHALL BE CUT ALONG A NEAT, VERTICAL LINE A MIN. OF 12" FROM THE EDGE OF THE TRENCH OPENING. WHERE NEAT LINE IS LESS THAN 3' FROM EDGE OF EXISTING PAVEMENT OR CURB & GUTTER SECTION, REMOVE AND REPLACE ENTIRE PAVEMENT SECTION BETWEEN TRENCH AND
EDGE OF PAVEMENT OR CURB & GUTTER SECTION.
SEE O.S.H.A. SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION, SECTION 1926.652. TRENCH
WALLS SHALL BE IN COMPLIANCE WITH THE CURRENT O.S.H.A. REQUIREMENTS.
NYSDOT TYPE 2 STONE SUBBASE
COMPACTED TO 95% OF ASTM D1557
MAXIMUM DENSITY UNLESS
OTHERWISE NOTED
BINDER COURSE
(SEE PAVEMENT SECTION DETAIL)
TOP COURSE
(SEE PAVEMENT SECTION DETAIL)
BACKFILL ABOVE BEDDING MATERIAL SHALL BE
COMPACTED TO 95% OF ASTM D698 MAXIMUM
DENSITY UNLESS OTHERWISE NOTED TO BE
COMPACTED IN MAXIMUM 6" LIFTS. IN PAVEMENT
AREAS, BACKFILL MATERIAL SHALL BE TYPE 2
STONE SUBBASE AND SHALL BE COMPACTED TO
95% OF ASTM D1557 MAXIMUM DENSITY, PER
PAVEMENT SECTION.
NTS
SOURCE: CALL24WIRELESS
SUBGRADE COMPACTED TO 95% OF
ASTM D698 MAXIMUM DENSITY
UNLESS OTHERWISE NOTED
6"
SUBGRADE COMPACTED TO 95% OF
ASTM D698 MAXIMUM DENSITY
UNLESS OTHERWISE NOTED
AutoCAD SHX Text Design - Repair Parking Lot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CS119
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Construction Details
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text X
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
Christopher W. Geary PE# 099085
Albany Stratton VAMC Albany, NY 12208
528A8-16-807
CH
RI
ST
OPHER WILLIAM GEARY
099085
S
T A T E OF NEW Y O
RK
L IC
ENSED PROFESSIONAL ENGI
NE
ER
ARCHITECT/ENGINEER OF RECORDCONSULTANT
Revisions: Date: 1/19/2021 Witczak Geary
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Dwg. of
Drawing Title
Approved:
Phase
Project Director
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
25 PRECAST CONCRETE STORM
MANHOLE/CATCH BASIN STRUCTURE
NTS
VARIES
SEE PLANS
PIPE INVERT
PIPE SIZE AND ELEVATION
AS PER PLAN
6" BOTTOM SLAB (MIN.)
6"
(TYP.)
OPENING ECCENTRIC OVER STEPS.
8" THICK OPENING TO BE OFFSET AS
REQUIRED FOR STEPS. DO NOT CAST
FRAME & COVER INTO ROOF OPENING
NON WOVEN
SEPARATION FABRIC
MANHOLE STEPS 12"
O.C.
12" MIN. OF SUBBASE (NYSDOT TYPE 2)
UNDISTURBED/UNEXCAVATED
EARTH
4000 PSI MIN. REINFORCED CONCRETE MANHOLE BY
FORT MILLER CO., OR APPROVED EQUAL. ASPHALT
WATERPROOFING COMPOUND APPLIED TO ENTIRE
EXTERIOR SURFACE STRUCTURE, 3 MIL DFT.
BUTYL ROPE SEALANT BETWEEN PRECAST
CONCRETE SECTIONS (TYP.)
HDPE STORM SEWER PIPE, SEE PLANS FOR SIZE AND
LOCATION. PLACE GASKETED, FLEXIBLE, WATER-TIGHT
NEOPRENE RUBBER BOOT CONNECTOR WITH CORRUGATED
PIPE ADAPTER BY NPC, INC. OR APPROVED EQUAL (TYP.).
KNOCKOUTS ARE PROHIBITED. ALL STRUCTURE PENETRATIONS
SHALL HAVE CAST IN PLACE BOOTS OR MACHINE CORED
HOLES. PIPE SIZE AND ELEVATION AS PER PLAN.
24" MIN (TYP.)
ADJUST MANHOLE FRAME TO GRADE WITH
MIN. 4000 PSI CONCRETE RISER SECTION OR
GRADE RINGS WITH NON-SHRINKING CEMENT
MORTAR (NYSDOT ITEM NO. 705-21). GRADE
RINGS TO BE 3" MIN TO 12" MAX.
CEMENT FILLET AROUND
PERIMETER OF FRAME
HEAVY DUTY FRAME AND COVER LABELED "STORM"
OR HEAVY DUTY FRAME AND GRATE. REFER TO
STRUCTURE TABLE ON PLANS FOR SIZE.
FINISHED GRADE OF CONCRETE
SIDEWALK/ASPHALT PAVEMENT
SUMP DEPTH AND ELEVATION
AS PER PLAN
26 PRECAST CONCRETE CATCH BASIN
STRUCTURE WITH CURB INLET
NTS
24 FLOW RATE CONTROL STRUCTURE WITH BUTTERFLY VALVE
NTS
NOTES:
1. STRUCTURE SHALL BE PRECAST. WEIR WALL SHALL BE CAST IN PLACE AND DOWELED INTO PRECAST BOX. THE
CONTRACTOR MAY SUBMIT AN ALTERNATE ENGINEERED DESIGN FOR EITHER:
A. THE WEIR WALL TO BE PRECAST MONOLITHICALLY WITH THE STRUCTURE WALLS.
B. A PRECAST WEIR WALL TO BE INSTALLED THAT WILL INCLUDE THE CONNECTION TO THE INSIDE OF THE CONTROL
STRUCTURE WALLS.
2. ALL FRP (FIBERGLASS REINFORCED PLASTIC) DOWELS SHALL HAVE A MINIMUM YIELD STRENGTH OF 30 KSI. THE
CONTRACTOR HAS THE OPTION TO PROVIDE ASTM A955 GRADE 60 STAINLESS STEEL DOWELS IN PLACE OF FRP
DOWELS.
3. THE CONCRETE SHALL HAVE A 28 DAY COMPRESSIVE STRENGTH OF 4,000 PSI.
5'
SECTION B - B
5'X'8 BOX WITH MH TOP
TOP OF WEIR WALL
(TOP ELEV.=190.50)
5'
8.0 5'
8" THICK 4,000 PSI CONCRETE
WEIR WALL. IF WEIR WALL IS
NOT CAST AS ONE MONOLITHIC
POUR WITH STRUCTURE, THE
CONTRACTOR SHALL BE SURE
THE JOINTS AT THE WEIR
WALL-INSIDE OF THE
STRUCTURE INTERFACE ARE
WATERTIGHT.
INSIDE OF STRUCTURE
BOUNDARY (TYP.)
BOTTOM OF PRECAST
CONCRETE TOP SLAB
2'
MI
N
STRUCTURE 102
8" THICK WEIR WALL
4"
" 9"
PROVIDE SIKA HYDROTITE CJ
TYPE WATER STOP OR
APPROVED EQUAL
SLAB TO WALL JOINT
4"
PROVIDE SIKA HYDROTITE CJ
TYPE WATER STOP OR
APPROVED EQUAL
WALL JOINT
4"
SECTION DETAIL
PROVIDE SIKA HYDROTITE
CJ TYPE WATER STOP OR
APPROVED EQUAL
WEIR WALL
(BOTTOM)
BASE SLAB OF INLET
1 PLAN VIEW WEIR WALL JOINT
SIDE WALL
PROVIDE SIKA
HYDROTITE CJ TYPE
WATER STOP OR
APPROVED EQUAL
WEIR WALL
#4 @ 12" OC BENT FRP DOWEL
MATCH HORIZONTAL REINF. OF
WEIR WALL
12" 12"
2 3 4
6"
POUR CONCRETE TO
FORM FLOW CHANNEL
STRUCTURE 102
5'X'8 BOX WITH MH TOP
PLAN VIEW
ADJUST MANHOLE FRAME TO GRADE WITH
MIN. 4000 PSI CONCRETE RISER SECTION OR
GRADE RINGS WITH NON-SHRINKING CEMENT
MORTAR (NYSDOT ITEM NO. 705-21). GRADE
RINGS TO BE 3" MIN TO 12" MAX.
CEMENT FILLET AROUND
PERIMETER OF FRAME
HEAVY DUTY FRAME AND
COVER LABELED "STORM"
FINISHED GRADE OF
ASPHALT PAVEMENT
2" TYP.
#4@12" OC BENT FRP DOWEL.
MATCH VERTICAL REINFORCING
OF WEIR WALL
12" 12"
12"
8" 8"
8"
8"
8"
8"
8'
SECTION A - A
5'X'8 BOX WITH MH TOP
BOTTOM BOX ELEV.=182.45
DETAIL 3 SEE DETAIL
4 @ SIDE WALLS
2"
DETAIL 1
#5 @ 12" OC
W/ CORNER
BARS
#6 @ 9" OC
CENTERED
IN WALL
#6 @ 9" OC
2"
POUR CONCRETE TO
FORM FLOW CHANNEL
#4 DIAG. BARS
AROUND OPENINGS
18" HDPE
INV.=183.05
18" HDPE
INV.=182.95
4" HDPE UNDERDRAIN
INV. 191.86
18" HDPE
INV.=183.05
TRASH
RACK
12" ORIFICE
INV.183.50
4" HDPE UNDERDRAIN
INV. 191.86
18" HDPE
INV.=182.95
18" HDPE TEMPORARY PIPE
INV.=182.95
(PLUG HOLE AFTER REMOVAL)
MANHOLE RIM
(VEHICULAR SAFE)
MANHOLE RIM
(VEHICULAR SAFE)
8" THICK WEIR WALL
TOP ELEV.=190.50
MANHOLE STEPS 12"
O.C. (TYP.)
REFER TO TRASH
RACK DETAIL
12" ORIFICE WITH TRASH
RACK ON UPSTREAM SIDE
OF PIPE (INV.=183.50)
MANHOLE STEPS 12"
O.C. (TYP.)
12" ORIFICE WITH
TRASH RACK ON UPSTREAM
SIDE OF PIPE (INV.=183.50)
ADDITIONAL
#4 BARS @4"
OC EACH SIDE
OF OPENING
18" HDPE
INV.=182.95
8" THICK WEIR WALL
TOP ELEV.=190.50
PRECAST CONCRETE
TOP SLAB
(HS-20 TRAFFIC RATED)
TRASH RACK
#6 @9" OC
#4 @12" OC
#5 @ 12" OC
18" HDPE TEMPORARY PIPE
INV.=182.95
9" THICK SLAB
(4,000 PSI CONCRETE)
8" THICK WALLS
(4,000 PSI CONCRETE)
NEMA 6P PLASTIC JUNCTION BOX
DETAIL 2 AS
NEEDED
REFER TO TRASH
RACK DETAIL
#4 @ 12" OC
CENTERED IN
WEIR WALLREFER TO "ACTUATED
VALVE DETAIL WEIR IN
OUTLET STRUCTURE"
DETAIL
CONCRETE PAD FOR VALVE
NOTES:
1. CONCRETE PAD SHALL BE 2'X2' AND SHALL BE 4,500 PSI.
2. CONCRETE PAD SHALL BE INSTALLED UNDER THE BUTTERFLY VALVE
FOR SUPPORT
#3 BARS (TYP.)
(TIE TO DOWELS)
(4) 1 1/2" FRP DOWELS
BOTTOM OF BOX
A A
5'
8'
3'-8" 8" 3'-8"
1'- 6"
1'- 6"
1-8"
REFER TO "PRESSURE
TRANSDUCER" DETAIL
4" HDPE UNDERDRAIN
INV. 191.86
18" HDPE
INV.=183.05
#4 BARS AROUND
OPENINGS (TYP.)
B
B
2"
2"
VARIES
SEE PLANS
PIPE INVERT
PIPE SIZE AND ELEVATION
AS PER PLAN
6" BOTTOM SLAB (MIN.)
6"
(TYP.)
OPENING ECCENTRIC OVER STEPS.
HEAVY DUTY TRAFFIC RATED FLAT
PRECAST CONCRETE SLAB (8" THICK)
NON WOVEN
SEPARATION FABRIC
MANHOLE STEPS 12"
O.C.
12" MIN. OF SUBBASE (NYSDOT TYPE 2)
UNDISTURBED/UNEXCAVATED
EARTH
4000 PSI MIN. REINFORCED CONCRETE MANHOLE BY
FORT MILLER CO., OR APPROVED EQUAL. ASPHALT
WATERPROOFING COMPOUND APPLIED TO ENTIRE
EXTERIOR SURFACE STRUCTURE, 3 MIL DFT.
BUTYL ROPE SEALANT BETWEEN PRECAST
CONCRETE SECTIONS (TYP.)
HDPE STORM SEWER PIPE, SEE PLANS FOR SIZE AND
LOCATION. PLACE GASKETED, FLEXIBLE, WATER-TIGHT
NEOPRENE RUBBER BOOT CONNECTOR WITH CORRUGATED
PIPE ADAPTER BY NPC, INC. OR APPROVED EQUAL (TYP.).
KNOCKOUTS ARE PROHIBITED. ALL STRUCTURE PENETRATIONS
SHALL HAVE CAST IN PLACE BOOTS OR MACHINE CORED
HOLES. PIPE SIZE AND ELEVATION AS PER PLAN.
24" MIN (TYP.)
ADJUST MANHOLE FRAME TO GRADE WITH
MIN. 4000 PSI CONCRETE RISER SECTION OR
GRADE RINGS WITH NON-SHRINKING CEMENT
MORTAR (NYSDOT ITEM NO. 705-21). GRADE
RINGS TO BE 3" MIN TO 12" MAX.
CEMENT FILLET AROUND
PERIMETER OF FRAME
HEAVY DUTY INLET FRAME AND GRATE/CURB BOX.
REFER TO PLANS FOR MORE INFORMATION.
FINISHED GRADE OF SIDEWALK/LAWN
SUMP DEPTH AND ELEVATION
AS PER PLAN
CURB BOX TO BE IN LINE WITH CURB
SUBBASE
PAVEMENT
STRUCTURE 102 OUTLET CONTROL STRUCTURE NOTES:
1. THE FLOW CONTROL MECHANISM AND APPURTENANCES TO BE INSTALLED IN THIS STRUCTURE HAVE
BEEN DESIGNED BY OPTIRTC, INC. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MATERIAL AND
LABOR COSTS FOR INSTALLATION OF ALL EQUIPMENT, AS SHOWN WITHIN THIS PLAN SET.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR BOTH MATERIAL AND LABOR COSTS FOR THE
CONCRETE STRUCTURE, INCLUDING ALL REINFORCEMENT, SLAB, MANHOLE LIDS AND FRAMES, STEPS, WEIR WALL, AND TRASH RACK. ADDITIONALLY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR BOTH MATERIAL AND LABOR COSTS FOR THE ELECTRIC FROM THE STRUCTURE TO THE HANDHOLE, FROM THE HANDHOLE TO THE VALVE CONTROL PANEL, ALL CONNECTIONS, AND THE ASSOCIATED BOLLARD.
3. NOTE THAT THE INTENDED USE OF THIS STRUCTURE IS AN OUTLET CONTROL DEVICE WITH A BUTTERFLY VALVE AND ALL APPURTENANCES. ALL ITEMS ASSOCIATED WITH THE VALVE HAVE BEEN DESIGNED BY OTHERS. ASSOCIATED DETAILS OF THE APPURTENANCES CAN BE FOUND WITHIN THIS
PLAN SET. ANY DISCREPANCY WITH THESE PLANS AND THE MANUFACTURER DESIGN, THE
MANUFACTURER DESIGN SHALL GOVERN. THE CONTRACTOR SHALL CONFIRM ANY CHANGES TO
STRUCTURE AND/OR COMPONENTS PRIOR TO ORDERING AND INSTALLING FOR CONFORMANCE WITH
ORIGINAL DESIGN.
4. THE CONTRACTOR IS REQUIRED TO SUBMIT A SHOP DRAWING OF STRUCTURE 102 AND RECEIVE
APPROVAL FROM THE ENGINEER AND COR PRIOR TO ORDERING.
NOTES:
1. COMBINATION INLETS SHALL BE NYSDOT TYPE E WITH TYPE F3 FRAME AND GRATE (GENERAL FOUNDRIES USF 5268 CURB AND GUTTER INLET FRAME (GRATE
CATALOG NO. 6698; HOOD CATALOG NO. 5267) OR APPROVED EQUAL).
2. GRATE INLETS SHALL BE NYSDOT TYPE E WITH TYPE F3 FRAME AND GRATE (GENERAL FOUNDRIES USF 4169 FRAME AND 6698 GRATE OR APPROVED EQUAL).
3. THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR EACH STRUCTURE PRIOR TO ORDERING
NOTES:
1. MANHOLE LIDS SHALL PROVIDE MINIMUM 24-INCH OPENING AND INCLUDE THE WORDS "STORM" (GENERAL FOUNDRIES USF 266 RING AND RU COVER, OR
APPROVED EQUAL). LIDS SHALL MEET H20 LOADING.
2. THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR EACH STRUCTURE FOR APPROVAL PRIOR TO ORDERING.
TRASH RACK INFORMATION
RACK WIDTH I.D. (W) = 18" (22" TOTAL)
RACK HEIGHT I.D. (H) = 18" (20" TOTAL)
RACK DEPTH O.D. (D) = 6"
BAR DIAMETER = 1/2"
BAR CENTERLINE SPACING = 2"
ORIFICE OPENING = 12"
ALUMINUM ROUND BAR
H
W
1/2 IN. HOLES FOR
3/8 IN. FASTENERS
4 x 2 IN. FLAT STOCK
(MOUNTED ON 3 SIDES MIN.)
D
NOTES:
1. ALL MATERIALS TO BE ALUMINUM 6061-T6 ALLOY.
2. WELD ALL INTERSECTIONS.
3. FASTEN TO CONCRETE STRUCTURE WITH 3/8 in. x 3 in. STAINLESS
STEEL CONCRETE WEDGE ANCHORS AT 18 in. MAX. SPACING.
MINIMUM OF (4).
4. OVERALL RACK WIDTH = (W) + 4 INCHES
5. OVERALL RACK HEIGHT = (H) + BAR DIAMETER + 2 INCHES
6. OPTIONAL - 10g STEEL WIRE MESH WITH 1 1/2 in. GRID TO COVER
RACK.
TRASH RACK
SOURCE: EFFLUENT DESIGN &
FABRICATION (MODIFIED)
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text X
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text Design - Repair Parking Lot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CS120
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Construction Details
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
528A8-16-807
CH
RI
ST
OPHER WILLIAM GEARY
099085
S
T A T E OF NEW Y O
RK
L IC
ENSED PROFESSIONAL ENGI
NE
ER
ARCHITECT/ENGINEER OF RECORDCONSULTANT
Revisions: Date: 1/19/2021 Witczak Geary
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Dwg. of
Drawing Title
Approved:
Phase
Project Director
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
32 OPTI CONTROL PANEL DETAIL POLE MOUNTED (LINE POWER)
NTS
SOURCE: OPTI (MODIFIED)
31 GENERIC DETAIL RAIN GAUGE
NTS
SOURCE: OPTI (MODIFIED)
30 ACTUATED VALVE DETAIL WEIR IN OUTLET STRUCTURE
NTS
SOURCE: OPTI (MODIFIED)
29 ORIFICE CLEARANCE DETAIL
NTS
SOURCE: OPTI (MODIFIED)
27 VALVE STEM MOUNT DETAIL WALL MOUNTED
NTS
SOURCE: OPTI (MODIFIED)
28 PRESSURE TRANSDUCER
NTS
SOURCE: OPTI (MODIFIED)
5 LF VALVE STEM EXTENSION SPECIFIED AND
PROCURED THROUGH OPTI
ACTUATOR SPECIFIED AND PROCURED THROUGH
OPTI
(SEE NOTE 2)
12 IN. BUTTERFLY VALVE SPECIFIED AND
PROCURED THROUGH OPTI, INV. EL. = 183.50
(SEE NOTE 5)
8 IN. FLANGED PIPE SECTION
WITH 18 IN. RUBBER GASKET
SPECIFIED AND PROCURED THROUGH OPTI
(SEE NOTE 6)
VALVE STEM MOUNTS
(SEE VALVE STEM MOUNT DETAIL)
OUTLET INV. EL. = 182.95 FT
OUTLET
MIN 3 FT FLEX. CONDUIT BETWEEN
JUNCTION BOX & ACTUATOR
(SEE NOTES 3 & 4)
RIGID CONDUIT CONNECTION
TO OPTI CONTROL PANEL
(SEE NOTE 3)
IP68 RATED JUNCTION BOX
(SEE NOTE 3)
NOTES:
1. OPTI SPECIFIED EQUIPMENT (TO BE PROCURED THROUGH OPTI):
1.1. ACTUATOR, BUTTERFLY VALVE, AND VALVE STEM EXTENSION (DELIVERED PRE-ASSEMBLED ON PALLET)
1.2. FLANGED PIPE SECTION AND RUBBER GASKET
1.3. POLYWATER FOAM DUCT SEALANT (SENT WITH OPTI CONTROL PANEL)
ALL OTHER EQUIPMENT TO BE PROCURED BY INSTALLATION CONTRACTOR.
2. ACTUATOR TO BE ORIENTED WITH WHEEL FACING AWAY FROM WALL. VALVES SHALL REST ON A POURED CONCRETE PAD (SEE DETAIL 24 ON SHEET CS120, "CONCRETE PAD FOR VALVE" DETAIL).
3. FLEXIBLE CONDUIT SHALL RUN FROM ACTUATOR TO JUNCTION BOX LOCATED IN OUTLET STRUCTURE. ALL CONDUIT ALONG WALL TO BE SECURED WITH #304 SS CLIPS (3' SPACING MAXIMUM). IP68 CORD GRIP REQUIRED FOR CONNECTION BETWEEN CONDUIT AND JUNCTION BOX. ALL CONDUIT CONNECTIONS TO BE IP68 RATED
AND SEALED WITH POLYWATER FOAM DUCT SEALANT.
4. FLEXIBLE CONDUIT SHALL BE 3/4". ACTUATOR CONDUIT PORT IS 34 IN. INTERNAL THREADED. SEE ELECTRICAL DIAGRAM.
5. FLANGE TO VALVE CONNECTION: 12 x 7⁄8 - 9 UNC FLANGE CONNECTOR BOLTS SHALL BE TIGHTENED TO 238-354 LB-IN TORQUE. ALL HARDWARE TO BE #304 SS.
6. FLANGE TO WALL CONNECTION: BOLT CAVITIES TO BE CLEANED OF DEBRIS USING AUTO CLEANING DRILL BIT OR COMPRESSED AIR PRIOR TO ANCHORING. BOLT CAVITIES TO BE FILLED WITH INJECTABLE ADHESIVE ANCHOR (HILTI HIT SERIES EPOXY #2123401 OR EQUIVALENT). BOLTS TO BE EMBEDDED TO MINIMUM DEPTH
SPECIFIED BY MANUFACTURER, 1 IN. CLEARANCE FROM REBAR.
7. TRASH RACK SPECIFIED BY THE ENGINEER OF RECORD TO BE PROCURED BY CONTRACTOR. TRASH RACKS ARE REQUIRED PRIOR TO OPERATION OF THE OPTI
ACTUATED VALVE AND SOFTWARE.
8. HOIST PLATE RATED TO 600 LBS. HOIST PLATE IS ANCHORED TO OUTLET STRUCTURE CEILING ABOVE THE ACTUATOR FOR MAINTENANCE AND REMOVAL OF
ACTUATOR.
TRASH RACK
(SEE NOTE 7)
HOIST PLATE RATED TO 600 LBS (SEE NOTE 8)
WEIR WALL EL. = 190.50 FT
INLET PIPE FROM BASIN
INV. EL. = 183.05 FT FLOW
NOTES:
1. OPTI SPECIFIED EQUIPMENT (TO BE PROCURED THROUGH OPTI):
a. 22 INCH X 18 INCH X 10 INCH NEMA 4X CABINET WITH CELLULAR ANTENNA AND
CHANNEL STRUT MOUNTING CLIPS
b. POLYWATER FOAM DUCT SEALANT (SENT WITH OPTI CONTROL PANEL)
2. GALVANIZED STEEL CHANNEL STRUT TO BE BOLTED TO SUPPORT POLE USING
GALVANIZED STEEL CHANNEL STRUT PIPE CLAMPS. CONTROL PANEL TO BE BOLTED TO
CHANNEL STRUT (CHANNEL STRUT MOUNTING CLIP SHIPPED WITH CONTROL PANEL).
PANEL TO BE MOUNTED MINIMUM 3 FT. FROM GROUND.
3. ALL CONDUIT PENETRATIONS ARE TO BE IP68 RATED AND SEALED WITH POLYWATER
FOAM DUCT SEALANT. SEE ELECTRICAL DIAGRAM FOR CABLE AND CONDUIT
SPECIFICATION.
4. ALL EQUIPMENT TO BE GROUNDED TO CONTROL PANEL GROUNDING LUGS. OPTI
CONTROL PANEL TO BE GROUNDED TO A GROUNDING ROD. (SEE GROUNDING ROD
DETAIL & ELECTRICAL DIAGRAM)
5. ALL ABOVE GROUND CONDUIT SHALL BE RIGID GALVANIZE STEEL (RGS) AND
UNDERGROUND CONDUIT SHALL BE PVC.
CONCRETE SLOPED TO SHED
WATER
3'
MI
NI
MU
M
(3) CONDUITS TO OUTLET
STRUCTURE AND LINE POWER
CONNECTION
2' 0.5
' 4,000 PSI CONCRETE
22 IN. (H) x 18 IN. (W) x 10 IN.
(D) OPTI CONTROL PANEL
SPECIFIED AND PROCURED
THROUGH OPTI (SEE NOTE 1)
CHANNEL STRUT AND PIPE
CLAMP (SEE NOTE 2)
24 IN.
LOW PROFILE CELLULAR
ANTENNA SPECIFIED AND
PROCURED THROUGH OPTI
MIN 8 LF. 4 IN. OD GALVANIZED STEEL
POLE WITH WATER TIGHT CAP
CONDUIT TO RAIN GAUGE
NYSDOT TYPE 1 STONE COMPACTED TO
95% OF ASTM D698 MAXIMUM DENSITY
UNLESS OTHERWISE NOTED
RGS TO PVC ADAPTER.
UNDERGROUND CONDUIT
SHALL BE PVC
(3) 1" CONDUITS TO HANDHOLE FOR
POWER AND CONTROL WIRING
(1) 1" CONDUIT TO RAIN GAUGE
CONCRETE SLOPED TO SHED WATER
1.75" GALVANIZED STEEL POLE
WITH WATER TIGHT CAP
TIPPING BUCKET RAIN
GAUGE
(SEE NOTE 1)
NOTES:
1. MOUNT TIPPING BUCKET RAIN GAUGE PER MANUFACTURERS INSTRUCTIONS.
2. RAIN GAUGE SHOULD BE SITED SUCH THAT SURROUNDING OBJECTS ARE NO CLOSER
THAN TWO TIMES THEIR HEIGHT ABOVE THE GAUGE.
3. ALL CONDUIT PENETRATIONS ARE TO BE IP68 RATED.
SERVICE DROP TO HOUSE
TIPPING BUCKET WIRE
12 IN. DIA
CONDUIT
(TO OPTI CONTROL PANEL)
HOSE CLAMP
2' 6'
4,000 PSI CONCRETE
NYSDOT TYPE 1 STONE
COMPACTED TO 95% OF ASTM D698 MAXIMUM
DENSITY UNLESS OTHERWISE NOTED
28 IN. MIN
FROM CENTERLINE TO
OUTLET SIDE WALL
MIN 5 12 IN. FROM
INVERT FOR FLANGE
SUPPORT
OUTLET STRUCTURE
WALL OR WEIR
12" LOW-FLOW ORIFICE (INV. 183.50)
182.95
IN
(M
AX
FLEXIBLE PIPE STRAPPING
(STAINLESS STEEL)
PERFORATIONS
MAX 1 IN. DIA
IN
O.
C.
MIN 6 IN. DIA.
PVC STILLING WELL
(SEE NOTE 2)
EX. STRUCTURE SIDEWALL
NOTES:
1. OPTI SPECIFIED EQUIPMENT (TO BE PROCURED THROUGH OPTI):
a. WATER LEVEL SENSOR (PRESSURE TRANSDUCER)
b. POLYWATER FOAM DUCT SEALANT (SENT WITH OPTI CONTROL PANEL)
ALL OTHER EQUIPMENT TO BE PROCURED BY INSTALLATION CONTRACTOR.
2. WATER LEVEL SENSOR TO REST WITHIN PVC STILLING WELL. SENSOR TO REST AT
BOTTOM OF FACILITY OR AT SPECIFIED MINIMUM ELEVATION.
3. BOTTOM OF JUNCTION BOX TO BE MOUNTED AT LEAST 4 IN. ABOVE OVERFLOW
ELEVATION.
4. PENETRATIONS INTO ALL EQUIPMENT AND CONNECTIONS WITHIN JUNCTION BOXES
SHALL BE IP68 RATED AND SEALED WITH POLYWATER FOAM DUCT SEALANT. SEE
ELECTRICAL DIAGRAM FOR CABLE AND CONDUIT SPECIFICATION.
5. CONDUIT SECURED ON WALL WITH STAINLESS STEEL CLIPS (3' MAX SPACING). PVC
STILLING WELL TO BE SECURED WITH STAINLESS STEEL PIPE STRAPPING (24 IN. MAX
SPACING).
6. PRESSURE REFERENCE DEVICE TO BE LOCATED IN OPTI CONTROL PANEL. DO NOT
SPLICE WATER LEVEL SENSOR CABLE.
7. MINIMUM 1 FOOT SPARE CABLING TO BE NEATLY COILED IN CONTROL PANEL FOR
FUTURE MAINTENANCE OR SYSTEM MODIFICATIONS.
OVERFLOW ELEVATION 190.5 FT
(SEE NOTE 3)
WATER LEVEL SENSOR
SPECIFIED AND PROCURED
THROUGH OPTI
(SEE NOTES 1 & 2)
CABLE AND CONDUIT CONNECTION TO IP68
JUNCTION BOX (SEE NOTES 3, 4 & 5)
FACILITY BOTTOM OR SPECIFIED
MINIMUM ELEVATION
PROFILE VIEW PLAN VIEW
NOTES:
1. OPTI SPECIFIED EQUIPMENT (TO BE PROCURED THROUGH OPTI):
a. VALVE STEM EXTENSION (DELIVERED WITH VALVE)
b. 12" x 1 5 8 IN. STRUT CHANNEL
c. 18" x 12 IN. ANCHOR RODS (2 PER STRUT)
d. STRUT-MOUNT ROUTING CLAMPS (2 PER STRUT)
2. ALL BRACKET MATERIALS MUST BE #304 STAINLESS STEEL.
3. MINIMUM SPACING: 1 VALVE STEM MOUNT FOR STEM LENGTH BELOW 3 FEET. ADD
VALVE STEM MOUNTS PER ADDITIONAL 3 FEET OF STEM LENGTH (MIN 2 VALVE STEM
MOUNTS REQUIRED).
4. 1
2 IN. ANCHOR ROD TO BE SET USING INJECTABLE ADHESIVE ANCHOR WITH AUTO
CLEANING DRILL BIT OR CLEAN HOLE THOROUGHLY WITH COMPRESSED AIR. USE
QUIKRETE HIGH STRENGTH ANCHORING EPOXY (PRODUCT #8620-31) OR APPROVED
EQUIVALENT. ROD SET IN CONCRETE MIN 3 IN..
STRUT-MOUNT ROUTING CLAMP
(MUST FIT TIGHT TO STEM)
VALVE STEM EXTENSION
SPECIFIED AND PROCURED
THROUGH OPTI
CUT TO LENGTH TO PLUM VALVE STEM EXTENSION
1 5 8 IN. STRUT CHANNEL
SPECIFIED AND PROCURED
THROUGH OPTI
OUTLET STRUCTURE WALL OR
WEIR WALL
2 IN. ANCHOR ROD
3 FT O.C.
(SEE NOTE 3)
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text X
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text Design - Repair Parking Lot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CS121
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Construction Details
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
528A8-16-807
CH
RI
ST
OPHER WILLIAM GEARY
099085
S
T A T E OF NEW Y O
RK
L IC
ENSED PROFESSIONAL ENGI
NE
ER
ARCHITECT/ENGINEER OF RECORDCONSULTANT
Revisions: Date: 1/19/2021 Witczak Geary
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Dwg. of
Drawing Title
Approved:
Phase
Project Director
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
34 ELECTRICAL DIAGRAM
NTS
SOURCE: OPTI (MODIFIED)
ELECTRICAL INSTALLATION NOTES
1. DETERMINE IF THERE ARE UNDERGROUND UTILITIES IN THE WORK AREA PRIOR TO EXCAVATION, BY CALLING DIG SAFE AT LEAST 48 HOURS PRIOR TO STARTING WORK.
CONTRACTOR SHALL BE LIABLE FOR ANY DAMAGE TO UNDERGROUND UTILITIES CAUSED BY TRENCHING OR EXCAVATION.
2. INSTALLATION OF THE CONTROL PANEL AND ASSOCIATED COMPONENTS (E.G., CABLING, CONDUIT, SENSORS) MUST BE PERFORMED BY A LICENSED ELECTRICIAN.
ELECTRICIAN SHALL BE RESPONSIBLE FOR ENSURING THAT THE CONTROL PANEL AND ASSOCIATED COMPONENTS ARE PROPERLY CONNECTED TO THE LINE POWER
SOURCE AND THAT CONDUIT AND CABLING IS SIZED AND INSTALLED PER THE NEC.
3. ALL CONDUCTORS SHALL BE IDENTIFIED AT EACH END (LABELED OR COLOR CODED) AND THE IDENTIFIED CONDUCTORS DOCUMENTED IN THE SITE LAYOUT MAP.
4. PENETRATIONS INTO CONTROL PANEL MUST BE IP68 RATED (NO WATER SHALL PENETRATE ANY SEALS). SUBSURFACE TERMINATIONS SHALL BE SEALED WITH
POLYWATER CLOSED-CELL FOAM DUCT SEALANT (PROCURED THROUGH OPTI WITH CONTROL PANEL).
5. ALL BURIED CONDUIT RUNS SHALL BE PER THE LIGHTING PLAN. BURIED CONDUIT SHALL BE INSTALLED PER THE ELECTRICAL TRENCH DETAIL.
6. LEAVE A MINIMUM OF 1 FOOT SPARE CABLING NEATLY COILED IN CONTROL PANEL FOR FUTURE MAINTENANCE OR SYSTEM MODIFICATIONS.
7. LEAVE A MINIMUM 3 FEET LOOP OF FLEXIBLE CONDUIT IN OUTLET STRUCTURE FOR EASE OF FUTURE MAINTENANCE. FLEXIBLE CONDUIT SHALL RUN FROM ACTUATOR
TO JUNCTION BOX LOCATED IN OUTLET STRUCTURE. RIGID CONDUIT SHALL RUN FROM JUNCTION BOX TO OPTI CONTROL PANEL.
8. ALL SUBMERGED/SATURATED METAL HARDWARE SHALL BE STAINLESS STEEL. GALVANIZED STEEL MAY BE USED ABOVEGROUND OR IN DRY LOCATIONS.
9. CONNECT ALL EQUIPMENT GROUNDING CONDUCTORS TO THE OPTI CONTROL PANEL GROUNDING LUGS. GROUND THE OPTI CONTROL PANEL TO A GROUNDING ROD, GALVANIZED STEEL POLE, OR A CONCRETE-ENCASED GROUNDING ELECTRODE.
10. AFTER INSTALLATION, COMPLETE CONTRACTOR INSTALLATION CHECKLIST PROVIDED BY OPTI AND PROVIDE PHOTOS OF ALL INSTALLED EQUIPMENT. SEND SIGNED
CHECKLIST AND PHOTOS TO OPTI AND COR.
11. PRESSURE REFERENCE DEVICE (COMPONENT OF LEVEL SENSOR AT CABLE TERMINATION) TO BE LOCATED IN OPTI CONTROL PANEL.
12. ALL CONDUCTORS THAT ARE GOING THROUGH THE HANDHOLE E-26 ON SHEET CS116 SHALL BE UNSPLICED.
13. OPTI WILL INSPECT INSTALLED COMPONENTS PRIOR TO ENERGIZING THE SYSTEM. FINAL COMPLETION SHALL BE REACHED WHEN:
(1) CONSTRUCTION OF THE SYSTEM PER THE PLANS IS COMPLETE;
(2) THE ENGINEER OF RECORD HAS COMPLETED FINAL INSPECTION OF WORK AND ALL NOTED DEFICIENCIES HAVE BEEN CORRECTED TO THE SATISFACTION OF THE
ENGINEER OF RECORD, OPTI, AND THE COR; AND
(3) AN AS-BUILT SKETCH HAS BEEN PROVIDED OF ALL INSTALLED COMPONENTS IF FINAL INSTALL LOCATIONS HAVE VARIED FROM PLANSET.
120VAC WIRING GUIDE - V 2.0.4
CONTROL PANEL
TERMINAL
EXTERNAL DEVICE
TERMINAL
WIRE COLOR/CABLE LOCATION PURPOSE PROCURED BY
LINE POWER CONNECTION
L1 ------------------- ------------------- 120VAC HOT, LINE POWER ------------------
N ------------------- ------------------- NEUTRAL, LINE POWER ------------------
GROUNDING NUT ------------------- ------------------- GROUND, LINE POWER ------------------
ACTUATOR - ROTORK IQT SERIES 393M2000
4 2 3 CONDUCTOR CABLE 120VAC HOT, ACTUATOR POWER INSTALLER
N 3 3 CONDUCTOR CABLE NEUTRAL, ACTUATOR POWER INSTALLER
GROUND LUG GND SYMBOL 3 CONDUCTOR CABLE GROUND, ACTUATOR POWER INSTALLER
5 26 4 CONDUCTOR CABLE VALVE POSITION COMMAND SIGNAL (+) INSTALLER
7 27 4 CONDUCTOR CABLE VALVE POSITION COMMAND SIGNAL (-) INSTALLER
10 22 4 CONDUCTOR CABLE VALVE POSITION CONFIRMATION SIGNAL (+) INSTALLER
2 23 4 CONDUCTOR CABLE VALVE POSITION CONFIRMATION SIGNAL (-) INSTALLER
A + 32 2 CONDUCTOR CABLE, SHIELDED TWISTED PAIR RS485 DATA (+) INSTALLER
B - 28 2 CONDUCTOR CABLE, SHIELDED TWISTED PAIR RS485 DATA (-) INSTALLER
PRESSURE TRANSDUCER (4-20mA) - PMC VL2000 SERIES
1 ------------------- RED (+), PMC PRESSURE TRANSDUCER, POWER OPTI
17 ------------------- BLACK (-), PMC PRESSURE TRANSDUCER, SIGNAL OPTI
S1 ------------------- GREEN (GND), PMC PRESSURE TRANSDUCER, GROUNDING OPTI
RAIN GAUGE - DAVIS
16 ------------------- RED RAIN GAUGE SWITCH OPTI
20 ------------------- GREEN RAIN GAUGE SWITCH OPTI
120VAC
LINE
POWER
SOURCE
3 CONDUCTORS
· HOT [L1]
· NEUTRAL [N]
· GROUND
6 CONDUCTORS
4 CONDUCTOR CABLE
· VALVE POSITION COMMAND (+) [5]
· VALVE POSITION COMMAND (-) [7]
· VALVE POSITION CONFIRMATION (+) [10]
· VALVE POSITION CONFIRMATION (-) [2]
2 CONDUCTOR CABLE SHIELDED TWISTED PAIR
· RS485 DATA (+) [A]
· RS485 DATA (-) [B]
[(4)#12 + (2)RS485 DATA CONTROL WIRE; 1" C PVC]
OPTI
CONTROL
PANEL
CELLULAR ANTENNA
RG174 COAXIAL CABLE
PANEL GROUND
CONDUCTOR NAME / CONDUCTOR COUNT IN CONDUIT
SUGGESTED # OF CONDUCTORS PER CABLE
· CONDUCTOR FUNCTION (+/-) [TERMINAL]
KEY:
RIGID CONDUIT (TYP)
FLEXIBLE CONDUIT
3 CONDUCTORS
FEP SENSOR CABLE - PROVIDED BY OPTI
· SENSOR PWR (+) [1]
· SENSOR SIGNAL (-) [17]
· SENSOR GROUND [S1]
[(3) MANUFACTURED CABLES; 1" C PVC]
3 CONDUCTORS
POWER CABLE
· ACTUATOR PWR (HOT) [4]
· ACTUATOR PWR (NEU) [N]
· ACTUATOR PWR (GND)
[(1)#10 + (1)#10N + (1)#10GRD; 1" C PVC]
VALVE
ACTUATOR
PRESSURE
TRANSDUCER
JUNCTION
BOX
2 CONDUCTORS
· SENSOR SIGNAL
· SENSOR SIGNAL
RAIN
GAUGE
JUNCTION BOX IS
LOCATED IN
STRUCTURE 102
MANUFACTURED 3/4"
FLEXIBLE CONDUIT FROM
JUNCTION BOX TO THE
VALVE ACTUATOR
FRONT VIEW SIDE VIEW
NOTES:
1. THE GROUNDING ROD MUST BE AT MINIMUM: COPPER COATED, 4 FEET IN LENGTH, AND 1/2 INCH IN
DIAMETER
2. THE GROUNDING ROD CLAMP WILL BE CLAMP STYLE, COPPER COATED, AND SIZED FOR THE
GROUNDING CABLE.
3. THE GROUNDING CABLE MUST BE SOLID COPPER, #8 AWG, AND LANDED AT THE GROUNDING ROD
CLAMP SECURELY AND LANDED IN THE CONTROL PANEL'S GROUNDING CABLE CLAMP.
4. ALL ENTRIES INTO THE CONTROL PANEL (INCLUDING THE GROUNDING CABLE) MUST BE
WATER-TIGHT AND SEALED.
5. THE GROUNDING ROD WILL BE SET AT LEAST 3 FEET BELOW THE SURFACE OF THE SOIL, UNLESS
OTHERWISE NOTED. AT A MAXIMUM, ONLY 6 INCHES OF ROD WILL BE EXPOSED ABOVE GROUND.
SOLID COPPER
GROUNDING CABLE
COPPER COATED
GROUNDING ROD CLAMP
COPPER COATED
GROUNDING ROD
33 GROUNDING ROD
NTS
SOURCE: OPTI (MODIFIED)
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text X
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text Design - Repair Parking Lot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CS122
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Construction Details
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
44 chambers 8 end caps
104 chambers 8 end caps
164 chambers 8 end caps
130 chambers 10 end caps
MC4500 CHAMBERS (104)
& END CAPS (8) EDGE OF STONE BED (AASHTO 3)
BOTTOM STONE ELEV.=184.00
AREA=19,350 SQ.FT.
479.5' [146.2m]
.1'
[11 .6m
6" PERFORATED UNDERDRAIN
(SET FLAT AT BOTTOM OF STONE BED)
INV. 184.00
MC4500 CHAMBERS (164)
& END CAPS (8)
MC4500 CHAMBERS (130)
& END CAPS (10)
24" PIPE STUB TO
ISOLATOR ROW
INV.=186.19
18" INLET MANIFOLD
WITH TWO (2) 18" PIPE STUBS
INV.=188.45 (TYP.)
SUBSURFACE DETENTION BASIN
MC4500 CHAMBERS (442) & END CAPS (34)
(OR APPROVED EQUAL) INV.=186.00
.2'
[14 .4m
119.8' [36.5m]
24" PIPE STUB TO
ISOLATOR ROW
INV.=186.19
24" PIPE STUB TO
ISOLATOR ROW
INV.=186.19
24" PIPE STUB TO
ISOLATOR ROW
INV.=186.19
24" PIPE STUB TO
ISOLATOR ROW
INV.=186.19
ISOLATOR ROW
(SEE DETAIL)
SCOUR PROTECTION, ADS 315W GEOTEXTILE (OR
APPROVED EQUAL) LOCATED AT ALL INLET/OUTLET
PIPE STUBS, MIN 14.5 FT IN LENGTH FROM OPENING
18" OUTLET MANIFOLD WITH
THREE (3) 18" PIPE STUBS
INV.=188.45 (TYP.)
24" INLET MANIFOLD WITH
THREE (3) 24" PIPE STUBS
INV.=187.92 (TYP.)
24" INLET MANIFOLD WITH
THREE (3) 24" PIPE STUBS
INV.=187.92 (TYP.)
18" INLET MANIFOLD
WITH TWO (2) 18" PIPE STUBS
INV.=188.45 (TYP.)
IN
FL
OW
IN
FL
OW
IN
FL
OW
IN
FL
OW
OU
TF
LO
W ISOLATOR ROW
(SEE DETAIL)ISOLATOR ROW
(SEE DETAIL)
ISOLATOR ROW
(SEE DETAIL)
NYSDOT, TYPE E 3'x4' INLET
(TYP.)
INSPECTION
PORT
INSPECTION
PORT
INSPECTION
PORT
INSPECTION
PORT
6" PERFORATED
HDPE UNDERDRAIN
6" PERFORATED
HDPE UNDERDRAIN
Christopher W. Geary PE# 099085
Albany Stratton VAMC Albany, NY 12208
528A8-16-807
CH
RI
ST
OPHER WILLIAM GEARY
099085
S
T A T E OF NEW Y O
RK
L IC
ENSED PROFESSIONAL ENGI
NE
ER
ARCHITECT/ENGINEER OF RECORDCONSULTANT
Revisions: Date: 1/19/2021 Witczak Geary
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Dwg. of
Drawing Title
Approved:
Phase
Project Director
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
CONCRETE SLAB
8" (200 mm) MIN THICKNESS
* THE PART# 2712AG6IPKIT
CAN BE USED TO ORDER ALL
NECESSARY COMPONENTS FOR
A SOLID LID INSPECTION PORT
INSTALLATION
MC-4500 CHAMBER
6" (150 mm) SDR35 PIPE
12" (300 mm) NYLOPLAST INLINE DRAIN
BODY W/SOLID HINGED COVER OR GRATE
PART# 2712AG6IP
SOLID COVER: 1299CGC
CONCRETE COLLAR
(DEPTH=8 IN.; 4,000 PSI)
PAVEMENT
6" (150 mm) INSERTA TEE
PART# 6P26FBSTIP*
INSERTA TEE TO BE CENTERED IN
VALLEY OF CORRUGATIONS
36 MC-4500 6" (150 mm) INSPECTION PORT DETAIL
40"
14"
SEAL LINER PENETRATION
WITH SOLVENT WELD
NTS
SOURCE: ADVANCED DRAINAGE SYSTEMS (MODIFIED)
35 MC-4500 END CAP INSERTION DETAIL
STORMWATER CHAMBER NOTES
1. CHAMBERS SHALL NOT BE INSTALLED UNTIL THE MANUFACTURER'S REPRESENTATIVE HAS COMPLETED A
PRE-CONSTRUCTION MEETING WITH THE INSTALLERS.
2. THE CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S CONSTRUCTION GUIDELINES.
3. CHAMBERS ARE NOT TO BE BACKFILLED WITH A DOZER OR EXCAVATOR SITUATED OVER THE CHAMBERS.
RECOMMENDED 3 BACKFILL METHODS:
· STONESHOOTER LOCATED OFF THE CHAMBER BED.
· BACKFILL AS ROWS ARE BUILT USING AN EXCAVATOR ON THE FOUNDATION STONE OR SUBGRADE.
· BACKFILL FROM OUTSIDE THE EXCAVATION USING A LONG BOOM HOE OR EXCAVATOR.
4. THE FOUNDATION STONE SHALL BE LEVELED AND COMPACTED PRIOR TO PLACING CHAMBERS.
5. JOINTS BETWEEN CHAMBERS SHALL BE PROPERLY SEATED PRIOR TO PLACING STONE.
6. MAINTAIN MINIMUM 9" (230 mm) SPACING BETWEEN THE CHAMBER ROWS.
7. INLET AND OUTLET MANIFOLDS MUST BE INSERTED A MINIMUM OF 12" (300 mm) INTO CHAMBER END CAPS.
8. EMBEDMENT STONE SURROUNDING CHAMBERS MUST BE A CLEAN, CRUSHED, ANGULAR STONE MEETING THE
AASHTO M43 DESIGNATION OF #3.
9. STONE SHALL BE BROUGHT UP EVENLY AROUND CHAMBERS SO AS NOT TO DISTORT THE CHAMBER SHAPE.
STONE DEPTHS SHOULD NEVER DIFFER BY MORE THAN 12" (300 mm) BETWEEN ADJACENT CHAMBER ROWS.
10. STONE MUST BE PLACED ON THE TOP CENTER OF THE CHAMBER TO ANCHOR THE CHAMBERS IN PLACE AND
PRESERVE ROW SPACING.
11. THE CONTRACTOR MUST REPORT ANY DISCREPANCIES WITH CHAMBER FOUNDATION MATERIAL BEARING
CAPACITIES TO THE SITE DESIGN ENGINEER.
12. THE USE OF EQUIPMENT OVER CHAMBERS IS LIMITED:
· NO EQUIPMENT IS ALLOWED ON BARE CHAMBERS.
· NO RUBBER TIRED LOADER, DUMP TRUCK, OR EXCAVATORS ARE ALLOWED UNTIL PROPER FILL DEPTHS
ARE REACHED IN ACCORDANCE WITH THE MANUFACTURER CONSTRUCTION GUIDELINES.
· WEIGHT LIMITS FOR CONSTRUCTION EQUIPMENT SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S
CONSTRUCTION GUIDELINES.
13. FULL 36" (900 mm) OF STABILIZED COVER MATERIALS OVER THE CHAMBERS IS REQUIRED FOR DUMP TRUCK
TRAVEL OR DUMPING.
USE OF A DOZER TO PUSH EMBEDMENT STONE BETWEEN THE ROWS OF CHAMBERS MAY CAUSE DAMAGE TO CHAMBERS AND IS NOT AN ACCEPTABLE BACKFILL METHOD. ANY CHAMBERS DAMAGED BY USING THE "DUMP AND PUSH" METHOD
ARE NOT COVERED UNDER THE STORMTECH STANDARD WARRANTY.
CONTACT STORMTECH AT 1-888-892-2694 WITH ANY QUESTIONS ON INSTALLATION REQUIREMENTS OR WEIGHT LIMITS
FOR CONSTRUCTION EQUIPMENT.
STORMWATER CHAMBER SPECIFICATIONS
1. CHAMBERS SHALL BE STORMTECH MC-4500 (OR APPROVED EQUAL).
2. CHAMBER ROWS SHALL PROVIDE CONTINUOUS, UNOBSTRUCTED INTERNAL SPACE WITH NO INTERNAL SUPPORT
PANELS THAT WOULD IMPEDE FLOW OR LIMIT ACCESS FOR INSPECTION.
3. THE STRUCTURAL DESIGN OF THE CHAMBERS, THE STRUCTURAL BACKFILL, AND THE INSTALLATION REQUIREMENTS SHALL ENSURE THAT THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, SECTION 12.12, ARE MET FOR: 1) LONG-DURATION DEAD LOADS AND 2) SHORT-DURATION LIVE LOADS, BASED ON THE AASHTO DESIGN TRUCK WITH CONSIDERATION FOR IMPACT AND MULTIPLE VEHICLE
PRESENCES.
4. CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418-16, "STANDARD SPECIFICATION FOR
POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS".
5. CHAMBERS SHALL BE DESIGNED AND ALLOWABLE LOADS DETERMINED IN ACCORDANCE WITH ASTM F2787, "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER
COLLECTION CHAMBERS".
6. ONLY CHAMBERS THAT ARE APPROVED BY THE SITE DESIGN ENGINEER WILL BE ALLOWED. THE CHAMBER MANUFACTURER SHALL SUBMIT THE FOLLOWING UPON REQUEST TO THE SITE DESIGN ENGINEER FOR APPROVAL
BEFORE DELIVERING CHAMBERS TO THE PROJECT SITE:
a. A STRUCTURAL EVALUATION SEALED BY A REGISTERED PROFESSIONAL ENGINEER THAT DEMONSTRATES THAT THE SAFETY FACTORS ARE GREATER THAN OR EQUAL TO 1.95 FOR DEAD LOAD AND 1.75 FOR LIVE
LOAD, THE MINIMUM REQUIRED BY ASTM F2787 AND BY AASHTO FOR THERMOPLASTIC PIPE.
b. A STRUCTURAL EVALUATION SEALED BY A REGISTERED PROFESSIONAL ENGINEER THAT DEMONSTRATES THAT THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, SECTION 12.12, ARE MET. THE 50 YEAR CREEP MODULUS DATA SPECIFIED IN ASTM F2418 MUST BE USED AS PART OF
THE AASHTO STRUCTURAL EVALUATION TO VERIFY LONG-TERM PERFORMANCE.
c. STRUCTURAL CROSS SECTION DETAIL ON WHICH THE STRUCTURAL EVALUATION IS BASED.
8. CUSTOM INVERT LOCATIONS CORED IN THE FIELD ON THE CHAMBER END CAPS ARE NOT PERMITTED. THE CONTRACTOR SHALL UTILIZE MOLDED THERMOPLASTIC END CAPS HAVING INTEGRAL PIPE STUBS PROVIDED BY
THE MANUFACTURER.
12" MIN. OF EMBEDMENT STONE (AASHTO 3)
ABOVE CHAMBERS (TYP.)
9" MIN 24" OF FOUNDATION STONE (AASHTO 3)
BELOW CHAMBERS (TYP.)
IMPERVIOUS LINER (30 MIL PVC)
WITH LAYER OF NONWOVEN FILTER FABRIC
(ADS 801T OR APPROVED EQUAL) ON BOTH
SIDES OF LINER ON ALL SIDES OF BASIN.
MC-4500
END CAP
(TYP.)
6" PERFORATED
HDPE UNDERDRAIN
INV.=184.00
BOTTOM STONE ELEV.=184.00
BOTTOM CHAMBER ELEV.=186.00
TOP STONE ELEV.=192.00
TOP CHAMBER ELEV.=191.00
REINFORCED FILL MATERIAL PER SPECIFICATION
FROM TOP OF LINER TO PAVEMENT SUBBASE
(REFER TO PAVEMENT SECTION)
REFER TO PLANS FOR
LOCATION AND NUMBER
OF CHAMBER ROWS
ISOLATOR ROW WITH WOVEN
STABILIZATION FABRIC (REFER
TO ISOLATOR ROW DETAIL)
UNDISTURBED SUBGRADE SOILS
(ANY SOILS DEEMED TO BE UNSUITABLE
SHALL BE REMOVED AND REPLACED PER
GEOTECHNICAL ENGINEERS DIRECTION)
37 SUBSURFACE BASIN CROSS SECTION
38 SUBSURFACE BASIN LAYOUT
BASIN LAYOUT
442 STORMTECH MC-4500 CHAMBERS
34 STORMTECH MC-4500 END CAPS
12 STONE ABOVE CHAMBERS (INCHES)
24 STONE BELOW CHAMBERS (INCHES)
40 STONE VOIDS (PERCENT)
70,720 INSTALLED SYSTEM VOLUME (CF) (PERIMETER STONE INCLUDED)
16,729 SYSTEM AREA (SF)
965 SYSTEM PERIMETER (FT)
BASIN ELEVATIONS
198.00 MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT)
193.00 MINIMUM BASE OF FLEXIBLE PAVEMENT
192.00 TOP OF STONE
191.00 TOP OF MC-4500 CHAMBER
188.45 18" TOP MANIFOLD INVERT
187.92 24" TOP MANIFOLD INVERT
186.19 24" ISOLATOR ROW CONNECTION INVERT
186.00 BOTTOM OF MC-4500 CHAMBER
184.00 6" UNDERDRAIN INVERT
184.00 BOTTOM OF STONE
IMPERVIOUS LINER (30 MIL PVC)
WITH LAYER OF NONWOVEN FILTER FABRIC
(ADS 801T OR APPROVED EQUAL) ON BOTH
SIDES OF LINER ON ALL SIDES OF BASIN.
NOTE: MANIFOLD STUB MUST BE LAID HORIZONTAL
FOR A PROPER FIT IN END CAP OPENING.
12" (300 mm)
MIN SEPARATION
12" (300 mm) MIN INSERTION
12" (300 mm)
MIN SEPARATION
12" (300 mm)
MIN INSERTION
MANIFOLD HEADER
MANIFOLD STUB
(ISOLATOR ROW)
STORMTECH MC-4500
END CAPS
MANIFOLD HEADER
MANIFOLD STUB
COVER ALL PIPE CONNECTIONS TO END CAPS WITH
ADS GEOSYNTHETICS 801T (OR APPROVED EQUAL)
NON-WOVEN GEOTEXTILE. IF PRE-CORED AND STUBBED
END CAPS ARE INSTALLED PIPE COVER IS NOT NECESSARY.
COVER ALL PIPE CONNECTIONS TO END CAPS WITH
ADS GEOSYNTHETICS 801T (OR APPROVED EQUAL)
NON-WOVEN GEOTEXTILE. IF PRE-CORED AND STUBBED
END CAPS ARE INSTALLED PIPE COVER IS NOT NECESSARY.
BASIN LINER NOTES
1. BASIN SHALL BE COMPLETELY WRAPPED WITH IMPERVIOUS LINER (30 MIL PVC) ON TOP, BOTTOM AND ALL SIDES.
THERE SHALL BE A LAYER OF NONWOVEN FILTER FABRIC (ADS 801T OR APPROVED EQUAL) ON BOTH SIDES OF
THE LINER ON ALL SIDES OF THE BASIN.
2. ALL SEAMS SHALL BE SEALED WITH A SOLVENT WELD. ALL PENETRATIONS, INCLUDING PIPES AND INSPECTION
PORTS SHALL BE SOLVENT WELDED AND UTILIZE A PIPE BOOT.
NTS
SOURCE: ADVANCED DRAINAGE SYSTEMS (MODIFIED)
NTS
SOURCE: ADVANCED DRAINAGE SYSTEMS (MODIFIED)
NTS
SOURCE: ADVANCED DRAINAGE SYSTEMS (MODIFIED)
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text X
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text Design - Repair Parking Lot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CS123
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Construction Details
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
528A8-16-807
CH
RI
ST
OPHER WILLIAM GEARY
099085
S
T A T E OF NEW Y O
RK
L IC
ENSED PROFESSIONAL ENGI
NE
ER
ARCHITECT/ENGINEER OF RECORDCONSULTANT
Revisions: Date: 1/19/2021 Witczak Geary
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Dwg. of
Drawing Title
Approved:
Phase
Project Director
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
A
SECTION A-A
STORMTECH CHAMBER (REFER TO PLAN FOR LAYOUT)
STORMTECH END CAP (REFER TO PLAN FOR LAYOUT)
MANIFOLD (REFER TO PLAN FOR LAYOUT)
ADS GEOSYNTHETICS 801T
NON-WOVEN GEOTEXTILE
(OR APPROVED EQUAL)
STORMTECH CHAMBER
DUAL WALL
PERFORATED
HDPE UNDERDRAIN
6" (150 mm) PERFORATED HDPE
42 BASIN UNDERDRAIN DETAIL
FOUNDATION STONE
BENEATH CHAMBERS
NTS
SOURCE: ADVANCED DRAINAGE SYSTEMS (MODIFIED) PART # STUB B C
MC4500REPE18TC
18" (450 mm) 29.36" (746 mm) ---MC4500REPE18TW
MC4500REPE18BC --- 1.97" (50 mm)
MC4500REPE18BW
MC4500REPE24TC
24" (600 mm) 23.05" (585 mm) ---MC4500REPE24TW
MC4500REPE24BC --- 2.26" (57 mm)
MC4500REPE24BW
NOTE: ALL DIMENSIONS ARE NOMINAL
NOMINAL CHAMBER SPECIFICATIONS
SIZE (W X H X INSTALLED LENGTH) 100.0" X 60.0" X 48.3" (2540 mm X 1524 mm X 1227 mm) CHAMBER STORAGE 106.5 CUBIC FEET (3.01 m³) MINIMUM INSTALLED STORAGE* 162.6 CUBIC FEET (4.60 m³) WEIGHT 130.0 lbs. (59.0 kg)
NOMINAL END CAP SPECIFICATIONS
SIZE (W X H X INSTALLED LENGTH) 90.2" X 59.4" X 30.7" (2291 mm X 1509 mm X 781 mm) END CAP STORAGE 35.7 CUBIC FEET (1.01 m³) MINIMUM INSTALLED STORAGE* 108.7 CUBIC FEET (3.08 m³) WEIGHT 135.0 lbs. (61.2 kg)
*ASSUMES 12" (305 mm) STONE ABOVE, 9" (229 mm) STONE FOUNDATION AND BETWEEN CHAMBERS, 12" (305 mm) STONE PERIMETER IN FRONT OF END CAPS AND 40% STONE POROSITY.
STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B"
STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T"
END CAPS WITH A WELDED CROWN PLATE END WITH "C"
END CAPS WITH A PREFABRICATED WELDED STUB END WITH "W"
B
C
52.0" (1321 mm)
48.3" (1227 mm)
INSTALLED
60.0" (1524 mm)
100.0" (2540 mm) 90.2" (2291 mm)
59.4" (1509 mm)
30.7" (781 mm)
INSTALLED
35.1" (891 mm)
BUILD ROW IN THIS DIRECTION
FOOT
UPPER JOINT
CORRUGATION
WEB
CREST
CREST
STIFFENING RIB
VALLEY
STIFFENING RIB
LOWER JOINT CORR.
41 MC-4500 CHAMBER SPECIFICATIONS
NTS
SOURCE: ADVANCED DRAINAGE SYSTEMS (MODIFIED)
ACCEPTABLE FILL MATERIALS: STORMTECH MC-4500 CHAMBER SYSTEMS
NOTES:
1. THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED AND ANGULAR.
2. STORMTECH COMPACTION REQUIREMENTS ARE MET FOR 'A' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 9" (230 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR.
NOTES:
1. MC-4500 CHAMBERS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F2418 "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS".
2. MC-4500 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION
CHAMBERS".
3. "ACCEPTABLE FILL MATERIALS" TABLE ABOVE PROVIDES MATERIAL LOCATIONS, DESCRIPTIONS, GRADATIONS, AND COMPACTION REQUIREMENTS FOR FOUNDATION, EMBEDMENT, AND FILL MATERIALS.
4. ONCE LAYER 'C' IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER 'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIAL REQUIREMENTS OF
LAYER 'C' OR 'D' AT THE SITE DESIGN ENGINEER'S DISCRETION.
5. PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS.
MATERIAL LOCATION DESCRIPTION AASHTO MATERIAL
CLASSIFICATIONS COMPACTION / DENSITY REQUIREMENT
D
FINAL FILL: FILL MATERIAL FOR LAYER 'D'
STARTS FROM THE TOP OF THE 'C' LAYER TO THE
BOTTOM OF FLEXIBLE PAVEMENT OR UNPAVED
FINISHED GRADE ABOVE. NOTE THAT PAVEMENT
SUBBASE MAY BE PART OF THE 'D' LAYER
SUITABLE FILL MATERIAL MEETING THE REQUIREMENTS OF
THE SPECIFICATIONS. REFER TO PLANS FOR PAVEMENT
SUBGRADE AND SUBBASE REQUIREMENTS.
N/A
PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVED
INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND
PREPARATION REQUIREMENTS.
C
INITIAL…