ATS List 2025.xlsx

XLSX spreadsheet 13 KB Posted

Attached to
J061--518-25-2-4829-0027: Services - 518-25-510 ATS Preventive Maintenance (VA-25-00034583)
Solicitation number
36C24125Q0219
Issued by

About this file

This is a combined Excel spreadsheet listing 39 Automatic Transfer Switches (ATS) at the Bedford VA Medical Center and a related RFQ for ATS preventive maintenance services. The RFQ (36C24125Q0219) seeks a contractor to provide annual preventive maintenance, inspection, and testing of ATSs and generator load bank testing. The procurement is a SDVOSB set-aside under NAICS 238210 with a $19M size standard.

Key requirements include annual PM on all listed ATSs, load bank testing for multiple generators (including 30% nameplate rating tests for 4 hours every 36 months), infrared scanning, and detailed documentation/reporting. The contract includes a base year and 4 option years, with responses due September 13, 2024. A site visit is scheduled for February 5, 2025. The contractor must provide trained technicians with proper certifications and follow NFPA, NETA, and OSHA standards. Notable equipment includes ASCO, Cummins, Kohler, RussElectric, and Zenith transfer switches located across multiple buildings. The work will be performed at the Edith Nourse Rogers Memorial Veterans Hospital in Bedford, Massachusetts, with consideration given to medical facility operations and critical patient care areas.

View the file

Other files

File Type Posted
2523-102-E706.pdf PDF
Generator 92 one-line.pdf PDF
generator 61 One line drawing.pdf PDF
January Generator PM Report.pdf PDF
Electrical Distribution upgrades one-line.pdf PDF
Automatic Transfer Switch Spec 263623.docx DOCX document
2523-102-E704.pdf PDF
2523-102-E701.pdf PDF
2523-102-E705.pdf PDF
VHA directive 1028.pdf PDF
generator 95 One line drawing.pdf PDF
generator 70 One line drawing.pdf PDF
ATS Testing and Generator Load Bank Testing RFIs.docx DOCX document
Generator 94 one-line.pdf PDF
36C24125Q0219_3.docx DOCX document
ATS service report April 2024.pdf PDF
2523-102-E703.pdf PDF
2523-102-E702.pdf PDF
Generator 93 one-line.pdf PDF
36C24125Q0219_2.docx DOCX document
ATS List 2024.xlsx XLSX spreadsheet
36C24125Q0219_1.docx DOCX document
Generator List.xlsx XLSX spreadsheet
36C24125Q0219.docx DOCX document
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Existing ATS
GeneratorATS #LocationManufacturerSerial #
19ATS-19Distribution Room 19ASCOJ07ATBB30400C5XC2159415 RE
22ATS-22Generator Room 22CumminsCHPCC-1208114G120e60099
6161-LSBldg 61 Dist. RoomASCOJ07ATBB30230C5XC1532765-003 RE
6161-EQBldg 61 Dist. RoomASCOJ07ATBB30400C5XC1532766-001 WE
6162-LSBldg 61 Dist. RoomASCOJ07ATBB30230C5ZC1532765-002 RE
6162-EQBldg 62 Dist. RoomASCOJ07ATBB30400C5ZC1532766-002 WE
7070-LSBldg. 70 Dist. RoomASCOJ07ATBB30230C5ZC1532765-001 RE
7070-EQBldg. 70 Dist. RoomASCOJ07ATBB30400C5ZC1532766-003 WE
7070-Fire PumpBldg. 70 Basement FiretrolASCOFTA593-AM100BFTA593-AM100B
9578-ATS-CRDBldg 78 mech. RoomASCOJ07ATBB3150C5XC1532767 WE
9578-ATS-EQDBldg 78 mech. RoomASCOJ07ATBB30400C5XC1532766-006WE
88-2Bldg 8 Dist. RoomKohlerA21237B
1010-1Bldg 10 Dist. RoomCumminsJ110264978
1010-1ABldg. 10 next to Dist. RoomCumminsJ110264968
9292-1Bldg. 1 LSASCOJ0AATSB3050C5XC2309699
9292-1Bldg. 2 EQ2ASCOJ0AATBB30260C5XC2052526 RE
9292-2Bldg. 2 LS1ASCOJ07ATBB30400C5XC2126513-001 RE
9292-2ABldg. 2 CRTASCOJ07ATBB30600C5XC2052527-001 RE
9292-2BBldg 2 EQ1ASCOH07ATBB30800C5XC2399484-001 we
9292-17Bldg 17 BasementASCOA300315041C112901-11
9292-18Bldg 18 BasementRUSSELECTRICRMT-1003CE7988-2
93B4-EQBldg. 4 Dist. RoomASCOJ07ATBB30600C5XC2052527-002 RE
93B4-LSBldg. 4 Dist. RoomASCOJ07ATBB30400C5XC2056566-002 RE
93Bldg . 4 Distribution Room 4 AASCOJ07ATBB30400C5XC2106757
93ATS1-LSBldg. 5 Dist. RoomASCOJ07ATBB30230C5XC2056564 RE
93ATS2-EQBldg. 5 Dist. RoomASCOJ07ATBB30400C5ZXC2056566-001 RE
9393-80Bldg. 80 Dist. RoomASCOJ07ATBB30150C5ZC2052525-001 RE
93Bldg. 82 Mechanical RoomASCOJ07ATBB30230C5XC2052521-001 RE
9494-4Bldg. 6EATON
9494-5Bldg. 6EATON
9494-6Bldg. 6EATON
9494-6aBldg. 6EATON
94B7-ATS2-EQBldg 7 Dist. RoomASCOJ07ATBB30400C5XC2052522-001 RE
94B7-ATS1-LSBldg 7 Dist. RoomASCOJ07ATBB30230C5XC2052521-002 RE
9578- LSDMechanical Room 78ASCOJ07ATBB30260C5XC1532768
9578-E1Mechanical Room 78ASCOJ07ATBB30600C5XC1532769 WE
9578-78AMechanical Room 78ASCOJ07ATBB30200C5ZC1532770 WE
95EP1Building 3ASCOJ07ATBB30400C5XC1532766-004 WE
95EP2Building 3ASCOJ07ATBB30400C5XC1532766-005 WE
Water TowerATSWater TowerZenithZBTS00B00026E151617092-10-1
Total39