This document is an amendment to Solicitation Number 36C24123R0112 for the project titled "Water Tank Painting and Repair" at the VA Medical Center in White River Junction, VT. The amendment provides responses to 13 Questions and Answers related to the Statement of Work (SOW) and extends the proposal due date to April 4, 2024 at 5:00 PM ET.

The key details are:

  • The VA will allow the use of static tanks with temporary pumps wired into the Building Management System (BMS) instead of the 6,000-gallon tanks specified in the original SOW.
  • The VAAR evaluation factors for Service-Disabled Veteran-Owned and Veteran-Owned Small Businesses will not be included, as the set-aside has been changed from SDVOSB to small business.
  • The VA will provide a copy of the Vermont Department of Environmental Conservation permit and water tower as-built drawings.
  • Alternate coating manufacturers will be acceptable if they meet the performance criteria.
  • The VA will provide water at no charge for disinfection following the coating work.
  • A NACE Level 3 inspector must support the onsite NACE Level 1 inspector for quality control.
  • Fencing of the project area is not required.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

5. PROJECT NUMBER (if applicable)

CODE

7. ADMINISTERED BY

2. AMENDMENT/MODIFICATION NUMBER

CODE

6. ISSUED BY

8. NAME AND ADDRESS OF CONTRACTOR

4. REQUISITION/PURCHASE REQ. NUMBER

3. EFFECTIVE DATE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED

PAGE OF PAGES

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED

BPA NO.

1. CONTRACT ID CODE

FACILITY CODE

CODE

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

E. IMPORTANT:

is extended,

(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.

12. ACCOUNTING AND APPROPRIATION DATA

(REV. 11/2016)

is required to sign this document and return ___________ copies to the issuing office.

is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

15C. DATE SIGNED

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER

Contractor

16C. DATE SIGNED

14. DESCRIPTION OF AMENDMENT/MODIFICATION

16B. UNITED STATES OF AMERICA

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER

16A. NAME AND TITLE OF CONTRACTING OFFICER

15B. CONTRACTOR/OFFEROR

STANDARD FORM 30

PREVIOUS EDITION NOT USABLE

Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)

(If required)

(SEE ITEM 11)

(SEE ITEM 13)

(X)

CHECK

ONE

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

(Signature of person authorized to sign) (Signature of Contracting Officer) 405-23-001 Department of Veterans Affairs VAMC Togus

NCO 01

1 VA Center Augusta

ME

04330 Department of Veterans Affairs VAMC Togus

NCO 01

1 VA Center Augusta

ME

04330 To all Offerors/Bidders

36C24123R0112 03-25-2024

X X X

Extended to April 4, 2024 at 5:00pm ET X

The purpose of this amendment is to:

1) Provide answers to RFI # 1 thru 13

2) Extend proposal due date to Thursday, April 4, 2024 at 5:00pm ET

All other terms and conditions remain unchanged.

Diane C. Davis Contracting Officer

NOTICE OF FOR PROPOSAL AMENDMENT

SOLICITATION NUMBER: 36C24123R0112

AMENDMENT NUMBER: 0003

DATE: March 25, 2024

PROJECT NUMBER: 405-23-001

PROJECT TITLE: Water Tank Painting and Repair LOCATION: VA Medical Center, White River Junction, VT 05009 REASON FOR AMENDMENT: Answer RFI Questions 1 thru 13 & Extend Proposal Deadline

AMENDMENT: 0003

Question 1 – SOW states “Contractor shall provide two temporary water storage tanks, each holding at least 6,000 gallons. Tanks shall be piped together and tied into the water service and distribution lines. The temporary water storage tanks shall be able to hold at least 70 PSI of water pressure”

· Using tanks that are 6,000 gals and able to handle at least 70 psi of pressure is tall order. Those type of tanks are very expensive at that size. Is it possible to use static tanks with temporary pumps that could be triggered from the BMS?

VA Response: Yes, that would be fine. The tanks are intended to be used as a temporary tower. The 70 PSI will be maintained with the water pumps in building 2. The VA intends to have the water service flow through the tanks to keep the stored water fresh. The tanks will be wired into the BMS system at the water tower. The BMS is a Siemens Desigo Building Automation system.

Question 2 – SOW states ” Water tanks shall be wired into the Building Management System (BMS) to communicate with the two VFD water tower supply pumps in building 2 to maintain a full condition. The water tanks will serve as a temporary water tower, providing an emergency supply of water to the campus in case of any failure by the municipal water system.

· We are not quite clear on what is needed and how to integrate the tanks into the BMS.

· What needs to be “integrated”? Is it the pressure and / or levels?

VA Response: A level indicator needs to be on the tanks to be sure they remain full.

Question 3 – Since the opportunity was changed from SDVOSB set aside to small business set aside, will the VAAR evaluation factors for SDVOSB/VOSBs be included 852.215-70 Service-Disabled Veteran-Owned and Veteran-Owned Small Business Evaluation Factors?

VA Response: No.

Question 4 – The solicitation documentation (SOW, section 3 Task & Requirements, number 12) contains a reference to completing the work in compliance with the “Vermont Department of Environmental Conservation, Drinking Water and Ground Water Protection Division VA Hospital Permit to Operate (WSID 12037) dated 6/6/17”. Will you please provide a copy of this document?

VA Response: Yes. See attachment.

Question 5 – For exterior pressure washing, are we required to capture water or allow it to run to the ground as long as we collect paint chips and other debris?

VA Response: Water is not required to be captured, as long as paint chips and other debris is collected.

Question 6 – Are there any as-builts showing details of the tank itself (e.g., detailed schematics for the tank, ladders, walkways, hard points that we can rig from, etc.) If so, will you please provide?

VA Response: Yes. See attachment.

Question 7 – Please confirm the Site Safety and Health Officer (SSHO) may also be the production supervisor.

VA Response: As long as both roles can be performed fully successfully, they may be managed by a single person.

Question 8 – Section 13 90 00 2.01.B. of the spec calls out Tnemec as basis of design and states that product by Jotun and Hempel coatings will also be considered if they meet the performance criteria. Will alternate manufacturers (e.g., Sherwin Williams, PPG, Carboline) be deemed acceptable if they meet the performance criteria?

VA Response: Yes, alternative manufacturers will be deemed acceptable if they meet performance criteria.

Question 9 – Section 13 90 00 3.01.B.1 calls out SSPC SP-11 Power Tool Cleaning to Bare Metal for all repair areas. Please confirm this is only for heavily rusted areas and that areas with sound coating are to be pressure washed in accordance with SSPC WJ-4 Low Pressure Water Cleaning in advance of overcoating.

VA Response: Correct.

Question 10 – No alternate for exterior surface prep and coating including full abrasive blast and recoat found in the specification. Please advise if this alternate price is to be provided.

VA Response: No alternate line items are proposed.

Question 11 – Will owner provide water at no charge for disinfection following coating scope of work?

VA Response: Yes.

Question 12 – Please confirm the third party inspector shall be at a minimum NACE CIP Level 1. (SOW, section 3 Task & Requirements, number 24B).

VA Response: NACE Level 1 inspector may be used to monitor the painting and cleaning and ensure compliance with the specifications. But the onsite NACE Level 1 inspector must be supported by a NACE Level 3 inspector to assist with technical support and quality control.

Question 13 – Are we required to fence the project area?

VA Response: No, access to natural gas plant needs to remain accessible.

See attached document: S02 - Permit to Operate_for VAMC_WSID 21037_07-07-17.

See attached document: S02 - 1993 Water Tower Plans.

Page 1 of

File details come from the government source that posted it. Updated .