10-AS201.pdf

PDF 263 KB Posted

Attached to
7230--JP Window Shades Federal contract opportunity
Solicitation number
36C24122Q0856
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1

View the file

Other files for this federal contract opportunity

Other files attached to 7230--JP Window Shades, newest first.
File Type Posted
10-AS100B.pdf PDF
36C24122Q0856_1.docx DOCX document
10-AS202.pdf PDF
10-AS100A.pdf PDF
10-AS203.pdf PDF
10-AS103A.pdf PDF
10-AS101B.pdf PDF
10-AS101A.pdf PDF
10-AS103B.pdf PDF
Line Items.pdf PDF
SOW Edited.pdf PDF
36C24122Q0856.docx DOCX document
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TOP OF SCREEN

WALL

52' - 1"

1ST Floor 0"

Ground Floor -14' - 0"

2nd Floor 14' - 0"

3rd Floor 28' - 0"

A B B.5 C D D.6 E F G

STAIR TOWER

ROOF

39' - 6"

C8 C7

C4

C4

C4

C8 C7

C7

C7 C8

C8C8

C8 C7

C7

T.O. ELEV. SHAFT

58' - 6"

C9

C6

C6

C6

C6

C6

C6

EXISTING STAIR TOWER

SIDING BEYOND

ACM PANELS

AREAWAY

7" 7"

7"

EQ EQ EQ EQ EQ

1'

1' - 5" 1' - 0" 1' - 5"

EACH OF THE PANELS ON

THIS FACE NOT DIMENSIONED

AS 7" IS 1' 11" HIGH - UNO

METAL FASCIA

THIS ACM PANEL JOINT

CENTERED BETWEEN WINDOWS

THESE ACM PANEL JOINTS

CENTERED ON C-WALL FRAMES

ALIGN

ALIGN

EQ EQ EQ

METAL FASCIA

/2

ALIGN HORIZONTAL ACM PANEL JOINTS

ON ELEVATOR SHAFT WALL WITH JOINTS

ON ADJOINING FACE (DIMENSIONED ON

SEPARATE ELEVATION)

1'

4" 3'

3'

7"

5'

9" 3'

3'

7"

5'

9" 3'

3'

7"

5'

9" 3'

THIS DASHED LINE

REPRESENTS TOP OF PRECAST

EXPOSED CONCRETE FND

WALL AT STAIR

PRECAST CONCRETE

WALL PANELS - ALIGN JOINTS WITH ACM PANEL

JOINTS AND/OR C-WALL FRAMES AS SHOWN

PR

EC

AS

T

4'

1/

2" 4'

4"

PR

E C

AS

T

1'

8"

LOWER ACM PANEL

THIS DASHED LINE REPRESENTS

FND SHELF10

ALIGN HORIZONTAL ACM PANEL

JOINTS WITH JOINTS ON

ADJOINING FACE (DIMENSIONED

ON SEPARATE ELEVATION)

ALIGN

AL

IG

N

BURIED CONCRETE VAULT

WITH PRECAST CAP FOR

FUTURE MRI REPLACEMENT

EQ EQ EQ

REMAINDER

REMAINDER

NOTE: ACM PANEL JOINTS NOT SPECIFICALLY

DIMENSIONED ARE TO ALIGN WITH THE SYSTEM

OF HORIZONTAL ACM PANEL JOINTS DIMENSIONED

ELSEWHERE ON THE EXTERIOR ELEVATIONS

THE COPING FOR THIS SCREEN WALL AND THE RETURN

WALLS AT THE ROOF LEVEL ARE FROM FORMED ACM

PANELS PER THE DETAILS - ALL OTHER TOP OF WALL

CONDITIONS HAVE THE SPECIFIED MTL FASCIA SYSTEM

PR

EC

AS

T

4'

1/

2"

ALIGN

THIS DASHED LINE

REPRESENTS TOP OF PRECAST

8'

/2

DASHED X-SQUARE IS LOCATION OF BACKUP

UNGROUTED CMU INFILL WALL TO BE REMOVED

FOR FUTURE MRI REPLACEMENT, REMOVE

SURROUNDING PRECAST AND ACM CLADDING

ELEMENTS AS REQ. FOR REMOVAL

PR

EC

AS

T

1'

8"

4'

4"

9'

0"

9'

8"

AS502

EXISTING 4TH

FLOOR

PENTHOUSE

40' - 0"

E-A

4th FLOOR/ROOF 42' - 0"

3 3.3 4

EQ EQ EQ EQ EQ

ACM PANELS

HORIZONTAL JOINTS TO ALIGN

WITH ADJIONING WALLS

SEE EXTERIOR DETAILS FOR

BOTTOM OF WALL FLASHING

SEE EXTERIOR DETAILS FOR

EXPANSION JOINT DETAILS

49 DARTMOUTH STREET

PORTLAND, ME 04101

207-775-1059 www.pdtarchs.com

ARCHITECTURE

INTERIOR DESIGN

PLANNING

Project Number

Building Number

Drawing NumberLocation

Project Title

Date Checked Drawn

Drawing Title

Approved: Project Director

Dwg:

ARCHITECT/ENGINEERS:CONSULTANTS:

DateRevisions:

1 2 3 4 5 6 7 8

A

B

C

D

E

VA FORM 08-6231, OCT 1978

on e e ig ht h in ch o ne fo ot on e q ua rte r i nc on e h al f th re e e ig ht hs th re e q ua rte rs i

6" on e i

6" on e a nd on e h a lf i nc he s on e f oo t 6"

Denis McLaughlin Telephone: 857-364-5149

1 2 3 4 5 6 7 8

Jamaica Plain, MA

A

B

C

D

E

M.E.P.:

Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376

SPECIFICATIONS:

Lowell Specifications, Inc.

34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001

STRUCTURAL:

Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822

CIVIL/LANDSCAPE:

Stantec Consulting 141 Portland St.

Boston, MA 02114 T: (617) 523-8103

AE Research Addition 523-307

0%

S

UB

MI

TT

AL

- B

ID

D

OC

UM

EN

TS

3-31-2016

Exterior Elevations

AS201

PNDW

3/16" = 1'-0"1 West Elevation

3/16" = 1'-0"2 ELEVATOR PENTHOUSE

Sheets
AS201 - Exterior Elevations