GENERAL SHEET NOTES
FLOOR PLANS:
1. Work from given dimensions. In general, large-scale details take precedence over smaller scale plans, elevations and building sections. Notify the Architect of any dimensional discrepancies prior to commencing the Work, and do not begin work until such discrepancies are resolved by the Architect.
2. Do not scale the drawings.
3. Dimensions indicated as "clear" shall be maintained in cases of discrepancy.
4. Masonry Opening or Rough Opening dimensions indicated are nominal dimensions.
Coordinate all Masonry Openings or Rough Openings with actual window unit, doorframe, or curtain wall/storefront sizes and requirements.
5. Dimensional Control:
• Exterior dimensions are to:
• Centerline of column
• Face of concrete
• Masonry opening
• Rough Opening
• Interior dimensions are to:
• Face of stud
• Face of masonry
• Centerline column
• Face of existing finish material
• Existing dimensions shall be verified. Report any discrepancies to the Architect.
6. Unless noted otherwise, the location of door frames shall be:
• CMU partitions: 4" from the adjacent wall to the hinge side of the rough opening.
• Metal stud partitions: 4" from the adjacent wall studs to the hinge side of the rough opening.
7. Typical Detail Notes:
The following notes are typical throughout this project and apply in all cases unless specifically noted otherwise. These notes and associated details may not be directly referenced on the drawings:
• All columns adjacent to or integral with exterior wall construction shall be enclosed within the wall construction unless noted otherwise.
• All columns located adjacent to or integral with GWB partitions shall be enclosed within the wall construction unless noted otherwise.
• All freestanding columns shall be enclosed.
• All roof leaders, heat piping, sprinkler risers, plumbing vents, sanitary plumbing or miscellaneous piping shall be enclosed within the wall construction.
• All duct penetrations through floors shall be enclosed in a chase.
• Slabs at all floor drains shall be pitched toward the drain.
AS203
AS201
E-A
E-4.7
E-5
E-6
E-5.6
E-6.8
E-7
E-AA
AS301
AS301
AS301
AS301
AS404
1 2 3 3.3 4
D
D.6
E
F
G
AS306
AS306
AS306
AS304
AS305
1.3 1.9
LAB
MODULE
3-11
LAB
MODULE
3-12
TEAM
LEADER
OFFICE
3-13
TEAM
LEADER
OFFICE
3-14
STAIR 2
3S-22 MECH
CLOSET
3-19
MENS
STAFF
TOILET
3-20
WOMENS
STAFF
TOILET
3-22
1/
2"
ES8C6-1
ES6C6
S4A
S4A
S4A
S4A
S4A S4A
S4A
S4A
S4S-2
S4S-2
S4B-2
S4B-2
S4A
S4S-2
S4S-2
ES8C6-1
S4A
ELEC.
ROOM
3-18
3-
3-
3-13
3-12
3-
3-
3-24
3-11
3-
ES6C8
S4S-2S
STAIR 4
3S-33
CORRIDOR
CR-3-16
CORRIDOR
CR-3-17
CORRIDOR
CR-3-15
IT-DATA
ROOM
3-23
S4S-2
S4F
S4S-2S
ES6C6
ES6C8
ES6C6
S4A
3-
ES6
S4F
S4F
7'
/2
R O
6'
0" 1'
5"
R O
6" 6"
1'
0" R
O
3'
/2
1'
3" 1'
2"
R O
3'
0" 6'
6"
12' - 5 3/4" 5' - 4 1/2"
5'
5"
5'-0" CLR MIN.
5' -0
" C
LR
M
IN
1' - 3"
1' - 2"
RO
3' - 0" 8' - 3 1/2"
RO
3' - 0" 8' - 3 1/2"
RO
3' - 0"
ES6C8
CLR
9' - 6 5/8"
MODIFY EXISTING
WOOD HANDRAIL
AND REINSTALL
ES6C6
ES6C6
3S -2
HKP
3-24
3S -3
35'-0" CLR MIN.
1.8
S4F
AS506
7'
1/
2" 1'
1/ 2"
S3F
11"4"
S2F
1'
6"
AS407
OPH
AS504
7' - 9"
S3F
7"
S4F
1' - 0 1/2"
EQ
EQ
6"
AS405
S2FS4F
AS401
D7
9"
9"
S4FS4A
AS304 THIS AREA DENOTES THE FOOTPRINT
OF EXISTING BUILDING 1F.
FLOOR PLAN LEGEND
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg:
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
VA FORM 08-6231, OCT 1978
on e e ig ht h in ch o ne fo ot on e q ua rte r i nc on e h al f th re e e ig ht hs th re e q ua rte rs i
6" on e i
6" on e a nd on e h a lf i nc he s on e f oo t 6"
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
Jamaica Plain, MA
A
B
C
D
E
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
3-31-2016
Third Floor Plan B
AS103B
PNDW
1/4" = 1'-0"2 3rd Floor Plan Area B Copy 1
| Sheets |
| AS103B - Third Floor Plan B |
File details come from the government source that posted it. Updated .