10-AS101A.pdf
PDF 394 KB Posted
- Attached to
- 7230--JP Window Shades Federal contract opportunity
- Solicitation number
- 36C24122Q0856
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 10-AS202.pdf | ||
| 10-AS100A.pdf | ||
| 10-AS203.pdf | ||
| 10-AS103A.pdf | ||
| 10-AS101B.pdf | ||
| 10-AS201.pdf | ||
| 10-AS100B.pdf | ||
| 36C24122Q0856_1.docx | DOCX document | |
| 10-AS103B.pdf | ||
| Line Items.pdf | ||
| SOW Edited.pdf | ||
| 36C24122Q0856.docx | DOCX document |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
FEC
AS203
AS202
E-A
E-B
E-C
E-4
E-5
TEAM
LEADER
OFFICE
1-14
TEAM
LEADER
OFFICE
1-13
STAIR 1
1S-11
ELEVATOR
G-30
PATIENT
TOILET
1-10
CONFERENCE
ROOM
1-16
EXAM
ROOM
1-09
BLOOD
DRAW
1-08
CONSULT
1-05
CONSULT
1-04
NOURISH
1-06
WAITING
1-02
AS303
AS301
AS301
AS301
AS301
AS302
AS302
AS302
AS302
AS402
AS305
1 2 3 3.3 4
A
B
B.5
C
D
RO
3' - 0" 8' - 3 1/2"
RO
3' - 0"
AS303
AS401
B2
AS401
B4
/1 AS101B
/1 AS101B
AS306
ES6C8
ES6C6
ES8C6-1
ES6C8
ES6C6
S4A
S4A S4A
S4A
S4A
S4A S4A
S4A
S4S-2
S4S-2
S4S-2
S4A
S4A
S4F
S4A
S4A
S4A S4A
S4A
ES8C6-1
S4F
ES6C8
ES6C6
ES6C6
1-
1-14
1-
1-
1-16
1-
1- 08 1-
1-
AS208 22
7'
/2
R O
6'
0" 1'
5"
R O
6" 6"
AS2065
AS206 3
S4F
AS205
AS205
EL. -7' - 0"
CORRIDOR
CR-1-23
CORRIDOR
CR-1-15
CONSULT
1-03
CORRIDOR
CR-1-01
1-42
1-
CR-1-01
S6A
S4S-2S
S8B-2
ES6C8
ES6C6
S6A
2'
RO
3' - 0"
R O
3'
0"
ES6C6
ES6C8
8' - 3 1/2"
6'
6"
7' - 5"
ES6
AS304
S4F S6A S6A
EL. 0"
AS20811
AS206 7
AS206
AS206
AS20611
AS205 4
EL. 0"
1.3 1.9
R O
3'
/2
1' - 3" 1' - 2"
1' - 3"
1'
2" 1'
3"
1'
3"
2' - 3"
5'
5"
23' - 10"
5' - 4 1/2"12' - 5 3/4"
11' - 6" 11' - 0 7/8" 10' - 0" 10' - 0" 10' - 1 3/4"
7'
/8 "3'
/8
1'
0"
9"
1S -1
4"
S4B-2
S4B-2
2' - 6"
AS507
AS507
AS507
AS507
AS507
AS507
AS507
AS507
S4F
ALIGN
VIF
2' - 11"
AS206
S4A
AS305
AS305
1'
1/
2"
R .O
SIM
8' - 5"
AS608
1'
S4F ABOVE -
CONTINUES
ACROSS OPENING,
SEE SECTION
ES8C6 ES8C6
9' - 6"
LAB
MODULE 1
1-17
CONSULT
1-39
KITCHEN
1-34
COPY/RECORDS
STORAGE
1-40
CORRIDOR
CR-1-33
1-40
1-
1-39
1-17
S4A
S2F
S4A S4A
S4A-1
S4A-1S6A
G S-
A
7' - 3 3/8"
AS608
AS608
paneling paneling paneling
PATIENT
TOILET
1-07
S6F
EXISTING BLDG 1F
1.8
5' - 5"
5'
1/
4"
8'
1/
4"
1/
2"6"
S6A
1/
2"
1/
2"
5 1/2"
/2
EQ
EQ
EQ
EQ
9'
1/
2"
7' - 9 7/8"
S4F 6'
4"
9"
7/
8"
S2F
S2F S3F
S3F
44x42
DUCT
24' - 6"19' - 2"
TB-1
AS206
2 REV SIM
SIM AT 2-09, 2-12, 3-10, 3-12
REV SIM AT 1-18, 2-08, 2-11, 3-11
AS407
EQ
EQ
AS20511
(5) 18"D ADJ
PLAM SHELVES
4"
72x26
DUCT
AS505
EXISTING COLUMN
9"
11' - 9"
Allow 1" space between counter and wall for seismic / expansion
2' - 1"
2'
1"
2'
1"
2'
0"
SUPPLY
1-42
3/
4"
5'
3/
4"
AS608
EXISTING BUILDING
1F LOBBY
GENERAL SHEET NOTES
FLOOR PLANS:
1. Work from given dimensions. In general, large-scale details take precedence over smaller scale plans, elevations and building sections. Notify the Architect of any dimensional discrepancies prior to commencing the Work, and do not begin work until such discrepancies are resolved by the Architect.
2. Do not scale the drawings.
3. Dimensions indicated as "clear" shall be maintained in cases of discrepancy.
4. Masonry Opening or Rough Opening dimensions indicated are nominal dimensions.
Coordinate all Masonry Openings or Rough Openings with actual window unit, doorframe, or curtain wall/storefront sizes and requirements.
5. Dimensional Control:
• Exterior dimensions are to:
• Centerline of column
• Face of concrete
• Masonry opening
• Rough Opening
• Interior dimensions are to:
• Face of stud
• Face of masonry
• Centerline column
• Face of existing finish material
• Existing dimensions shall be verified. Report any discrepancies to the Architect.
6. Unless noted otherwise, the location of door frames shall be:
• CMU partitions: 4" from the adjacent wall to the hinge side of the rough opening.
• Metal stud partitions: 4" from the adjacent wall studs to the hinge side of the rough opening.
7. Typical Detail Notes:
The following notes are typical throughout this project and apply in all cases unless specifically noted otherwise. These notes and associated details may not be directly referenced on the drawings:
• All columns adjacent to or integral with exterior wall construction shall be enclosed within the wall construction unless noted otherwise.
• All columns located adjacent to or integral with GWB partitions shall be enclosed within the wall construction unless noted otherwise.
• All freestanding columns shall be enclosed.
• All roof leaders, heat piping, sprinkler risers, plumbing vents, sanitary plumbing or miscellaneous piping shall be enclosed within the wall construction.
• All duct penetrations through floors shall be enclosed in a chase.
• Slabs at all floor drains shall be pitched toward the drain.
THIS AREA DENOTES THE FOOTPRINT
OF EXISTING BUILDING 1F.
FLOOR PLAN LEGEND
49 DARTMOUTH STREET
PORTLAND, ME 04101
207-775-1059 www.pdtarchs.com
ARCHITECTURE
INTERIOR DESIGN
PLANNING
Project Number
Building Number
Drawing NumberLocation
Project Title
Date Checked Drawn
Drawing Title
Approved: Project Director
Dwg:
ARCHITECT/ENGINEERS:CONSULTANTS:
DateRevisions:
1 2 3 4 5 6 7 8
A
B
C
D
E
VA FORM 08-6231, OCT 1978
on e e ig ht h in ch o ne fo ot on e q ua rte r i nc on e h al f th re e e ig ht hs th re e q ua rte rs i
6" on e i
6" on e a nd on e h a lf i nc he s on e f oo t 6"
Denis McLaughlin Telephone: 857-364-5149
1 2 3 4 5 6 7 8
Jamaica Plain, MA
A
B
C
D
E
M.E.P.:
Stantec 482 Payne Road Scarborough, ME 04074 T: (207) 883-3355 F: (207) 883-3376
SPECIFICATIONS:
Lowell Specifications, Inc.
34 Marc Avenue Topsham, ME 04086 T: (207) 406-4001
STRUCTURAL:
Becker Structural Engineers 75 York St Portland, ME 04101 T: (207) 879-1838 F: (207) 879-1822
CIVIL/LANDSCAPE:
Stantec Consulting 141 Portland St.
Boston, MA 02114 T: (617) 523-8103
AE Research Addition 523-307
0%
S
UB
MI
TT
AL
- B
ID
D
OC
UM
EN
TS
3-31-2016
First Floor Plan A
AS101A
PNDW
1/4" = 1'-0"1 1st Floor Plan Area A
| Sheets |
| AS101A - First Floor Plan A |