E2.0L_ FIRST FLOOR LIGHTING PLAN Rev.0 markup.pdf
PDF 874 KB Posted
- Attached to
- Z1AA--347-Boise RO Facility Maintenance Services
- Solicitation number
- 36C10D24Q0188
- Issued by
-
Department of Veterans Affairs
About this file
This document is the First Floor Lighting Plan for the Construct National Telehealth Hub project at the Boise VA Medical Center. The plan shows the layout and configuration of lighting fixtures on the first floor, including existing lights to remain, new lights to be installed, and modifications to the lighting control system. Key details include:
The lighting system will utilize the existing lighting control panel, with a new lighting control panel added on the second floor to provide networked lighting control. Existing lighting fixtures on the interior and exterior are to remain unless noted for removal. New lighting fixtures will be integrated with the existing branch circuiting and controls. The scope includes adding an unswitched lighting circuit for exit signs, and coordinating the new lighting layout with architectural elements. The plan references additional information on the second floor lighting plan.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| E2.1L_ SECOND FLOOR LIGHTING PLAN Rev.0 markup.pdf | ||
| 36C10D24Q0188 0003.docx | DOCX document | |
| 2nd floor floorplan.pdf | ||
| As-builts First Floor.pdf | ||
| Maintenance Milestone Schedule.docx | DOCX document | |
| 36C10D24Q0188 0002.docx | DOCX document | |
| 36C10D24Q0188 0001.docx | DOCX document | |
| PAST PERFORMANCE QUESTIONAIRE.docx | DOCX document | |
| 36C10D24Q0188.docx | DOCX document | |
| Wage Determination.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D B
'L3B'
'L2'
'T2'
'M
SB'
'H1'
'L1'
'L3A'
'LCP'
'T3' 'T1'
'DSB-2'
M
UP
UP
N
M
L
3 5
J
7 9 11 15 17 19 21 23 25
F
E
D
C
B
A 2
G
2.5
INFILL @ (E) WINDOW
LOCATION. PATCH TO
MATCH EXISTING
ADJACENT MATERIALS,
CONSTRUCTION, AND
FIRE RATING.
PATCH TO MATCH EXISTING
ADJACENT FINISHES
AREA OF FUTURE DOOR; SEE SHEET
A-711 FOR EXACT EXTENTEXTEND FURRED COLUMN AS NEEDED TO
ACCOMODATE RELOCATED HOSE BIB. SEE
PLUMBING DRAWINGS FOR DETAILS
VESTIBULE
RVSR
COACH
OFFICE
ELECTRICAL
ROOM
VSC
COACH
VSC
COACH
TRAINING/CONFERENCE
STORAGE
CONFERENCE
SECURED
FILE
ROOM
EQUIPMENT
SHARED
PANTRY
TOILET
CLOSET
H.R.
DIRECTOR
VESTIBULE
RECEPTION/DIRECTOR
SUITE
HALL
ROOM
VESTIBULE
REPRODUCTION/PUBLICATION
DIV.
CHIEF
SUPPORT
SERVICE
DIVISION
VSC
MANAGER
LOCKED
FILE
ROOM
OPEN
AREA
SERVICE
CENTER
OPEN
OFFICE
LOUNGE
ELECTRICAL
ROOM
MEP
SHOWER
MEN
JAN.
WOMEN
IRM
COMPUTER
ROOM
TRAINING
ROOM
INFORMATION
SECURITY
OFFICER
IDVS
DIRECTOR
IDVS
DAV
OFFICE
DAV
UNION
OFFICE
FILE
ROOM
CONFERENCE
VR&E
DIVISION
CHIEF
COUNSELOR
COUNSELOR
COUNSELOR
JOB LAB
LOAN
GUARANTY
COUNSELOR
F&FE
TOILET
TOILET
INTERVIEW
ROOM
INTERVIEW
ROOM
HALL
EQUIPMENT
VR&E
LOBBY
CORRIDOR
HALL
ELEVATOR
LOBBY
100D
ELEVATOR
MACHINE
ROOM
100A
D
D D
D
D
D
C3
C3
D
D
D D
H4-11 7 8
K
K
C
D
X5
X
5 X
W
W
W
W
12W
KEYED NOTES: #
GENERAL NOTES:
1 EXISTING LC&D LIGHTING CONTROL PANEL, EXISTING LIGHTING CONTROL
PANEL TO REMAIN, NEW LIGHTING BRANCH CIRCUIT IN ENTRY LOBBY TO
BE CIRCUITED TO EXISTING SPARE LIGHTING RELAY IN PANEL. PANEL IS
TO BE NETWORKED TO NEW LIGHTING CONTROL PANEL LOCATED ON THE
SECOND FLOOR. SEE SHEET E2.1L FOR ADDITIONAL INFORMATION.
2 NEW ENTRY AREA, SHOWN FOR REFERENCE TO EXISTING AREAS.
3 NEW STAIRWELL, SHOWN FOR REFERENCE TO EXISTING AREAS.
4 EXISTING FIRST FLOOR LIGHTING FIXTURES ON INTERIOR AND EXTERIOR
ARE TO REMAIN, UNLESS OTHERWISE NOTED ON E2.0D FOR REMOVAL.
DEVICES ARE SHOWN FOR INFORMATIONAL PURPOSES AND REFERENCE
ONLY. ALL EXISTING BRANCH CIRCUITING AND CONTROLS ARE TO BE
MAINTAINED.
5 CONNECT TO UNSWITCHED LEG OF LIGHTING CIRCUIT IN ROOM.
6 UP TO LIGHT FIXTURES IN STAIR. SEE SHEET E2.1L FOR ADDITIONAL
INFORMATION.
7 ROUTE THROUGH EXISTING SPARE RELAY IN LIGHTING CONTROL PANEL,
SEE KEYNOTE 1 ON THIS SHEET. UTILIZE EXISTING SPARE RELAY IN
EXISTING LCP FOR LIGHTING CONTROL.
8 FURNISH AND INSTALL ADDITIONAL UNSWITCHED LEG OF LIGHTING
CIRCUIT FOR CONNECTION TO EXIT SIGNS.
9 FURNISH NETWORK CONNECTION TO NEW SLAVE LIGHTING CONTROL
PANEL LOCATED IN THE SECOND FLOOR ELECTRICAL ROOM. SEE SHEET
E2.1L FOR ADDITIONAL INFORMATION.
10 REFER TO SECOND FLOOR LIGHTING PLAN E2.1L FOR LIGHTING LAYOUT,
BRANCH CIRCUITING, AND CONTROLS FOR THIS AREA.
11 EXISTING LIGHT FIXTURE TO BE RELOCATED TO THIS LOCATION. SEE
SHEET E2.0D FOR COORDINATION WITH EXISTING FIXTURE BEING
RE-LOCATED AND ASSOCIATED BRANCH CIRCUITING MODIFICATIONS.
12 COORDINATE MOUNTING OF NEW LIGHT FIXTURE WITH ARCHITECTURAL
ELEVATIONS.
13 EXTEND EXISTING BRANCH CIRCUITING TO RE-LOCATED AND NEW LIGHT
FIXTURES. SEE SHEET E2.0D FOR ADDITIONAL INFORMATION. CONTROL
NEW FIXTURES WITH EXISTING.
1 ALL EXISTING LIGHTING IS TO REMAIN AND IS SHOWN FOR REFERENCE
ONLY, UNLESS NOTED OTHERWISE.
electricalengineeringcompany engineering 4 tomorrow
800 s. industry way, suite 350 meridian, idaho 83642 phone: 208.378.4450 fax: 208.378.4451 e2co project #:
world wide web: e2co.com
18237
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
JVS JVS/JB/DTLFULLY SPRINKLERED
Revisions: Date:
Approved:
CONSTRUCTION
DOCUMENTS
1001 Connecticut Avenue NW, Suite 704 Washington, DC 20036
(855) 521-1110 Mr. Gene Klow, AIA
Concourse Federal Group
08/16/2019
Construct National Telehealth Hub, Boise VAMC
531-323
347-1
444 W Fort Street, Boise, Idaho E2.0L
FIRST FLOOR LIGHTING PLAN
SCALE: 1/8" = 1'-0"
FIRST FLOOR LIGHTING PLAN
SHEET 124 OF 145
AutoCAD SHX Text S https://us02.procore.com/562949953469612/project/drawing_areas/562949953455220/drawing_log/562949956772057 https://us02.procore.com/562949953469612/project/drawing_areas/562949953455220/drawing_log/562949956772057 https://us02.procore.com/562949953469612/project/drawing_areas/562949953455220/drawing_log/562949956772057 https://us02.procore.com/562949953469612/project/drawing_areas/562949953455220/drawing_log/562949956772057 https://us02.procore.com/562949953469612/project/drawing_areas/562949953455220/drawing_log/562949956772083 https://us02.procore.com/562949953469612/project/drawing_areas/562949953455220/drawing_log/562949956772047 https://us02.procore.com/562949953469612/project/drawing_areas/562949953455220/drawing_log/562949956772047 https://us02.procore.com/562949953469612/project/drawing_areas/562949953455220/drawing_log/562949956772047 K