This is a Schedule of Line Items and Questions & Answers document for the VA's December 2025 Equipment Only Consolidation procurement (Solicitation 36A79726Q0004). The document consolidates 32 medical imaging and diagnostic equipment line items across 13 VA Integrated Service Networks, including X-ray systems, ultrasound equipment, MRI systems, CT scanners, interventional radiology devices, catheterization laboratory equipment, and nuclear medicine gamma cameras. Equipment quantities range from single units to seven units per line item, distributed across VA medical facilities nationwide from West Roxbury, Massachusetts to Temple, Texas. Eligible offerors must be current contract holders with the VA National Acquisition Center High Tech Medical Equipment Branch or Defense Logistics Agency Troop Support with active contracts at both offer submission and award; new product additions not previously implemented are prohibited.

The Questions & Answers section addresses technical clarifications for specific line items, including detailed specifications adjustments. For VISN 1's West Roxbury ultrasound system (523B51012), minimum monitor size was updated to 19 inches, image storage increased to 500GB, 4D capability removed from requirements, and image fusion capability (rather than requirement) added to the value-added section for MRI-ultrasound correlation. For VISN 10's ultrasound systems across Ohio facilities, clarifications confirmed self-paced training only, identified traded-in transducers (Boston Scientific EDGE model and Mindray TE7 systems), confirmed purchase quantities, and added endovaginal and wideband 15 MHz linear probe specifications. Vendor question submission deadline is February 18, 2026 at 11:59 PM CST, with offer submission required by April 8, 2026 at 11:59 PM CST and goal award date of August 11, 2026. Evaluation methodology employs best-value with equally weighted non-price factors for availability of required features and service availability, combined with price analysis for award determination.

View the file

Other files

File Type Posted
36A79726Q0004 0003.docx DOCX document
DEC 2025 EQ Consolidation - RFO Updated.docx DOCX document
Continuation page..docx DOCX document
36A79726Q0004 0002.docx DOCX document
36A79726Q0004 0001.docx DOCX document
Updated Zipped Files.zip ZIP file
Vendor Folders.zip ZIP file
VA Directive 6550 - New Appendix A - published Jun. 2023.pdf PDF
Memorandum for Training.pdf PDF
DEC 2025 EQ Consolidation - RFO.docx DOCX document
36A79726Q0004_1.docx DOCX document
558B69003 - 674B60111.zip ZIP file
Copy of DEC 2025 EQ Consolidation - Schedule of Line Items-NAC-HTM.xlsx XLSX spreadsheet
VA Directive 6550 - New Appendix A - published Jun. 2023 02.pdf PDF
506B60008 - 558B69002.zip ZIP file
DEC 2025 Equipment Only Consolidation Schedule.pdf PDF
Vendor Workup Spreadsheet - 36A79726Q0004.xlsx XLSX spreadsheet
Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VISN Names

HTME VISN
VISN 1: VA New England Healthcare System
VISN 2: VA Healthcare Network Upstate New York
VISN 4: VA Stars & Stripes Healthcare Network
VISN 5: VA Capitol Health Care Network
VISN 6: VA Mid-Atlantic Health Care Network
VISN 7: VA Southeast Health Care Network
VISN 8: VA Sunshine Healthcare Network
VISN 9: VA Mid South Healthcare Network
VISN 10: VA Healthcare System of Ohio
VISN 12: VA Great Lakes Health Care System
VISN 15: VA Heartland Network
VISN 16: South Central VA Health Care Network
VISN 17: VA Heart of Texas Health Care Network
VISN 19: VA Rocky Mountain Network
VISN 20: VA Northwest Network
VISN 21: VA Sierra Pacific Network
VISN 22: VA Desert Pacific Healthcare Network
VISN 23: VA Midwest Health Care Network

Schedule of Line Items

HTME VISNStationEQ POEquipment TypeQTY
VISN 1: VA New England Healthcare System523 WEST ROXBURY MA523B51012XR US1
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63003XR IR1
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63002XR CATH LAB1
VISN 2: VA Healthcare Network Upstate New York528 BUFFALO NY528B60115XR URO1
VISN 2: VA Healthcare Network Upstate New York528 BUFFALO NY528B60114XR URO1
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B62001XR US1
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B62004XR US1
VISN 5: VA Capitol Health Care Network540 CLARKSBURG WV540B61004XR MRI1
VISN 5: VA Capitol Health Care Network512 BALTIMORE MD512B60604XR HYBRID1
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND VA652B59013NM GAMMA CAMERA1
VISN 6: VA Mid-Atlantic Health Care Network558 GREENVILLE NC558B69004XR RAD1
VISN 6: VA Mid-Atlantic Health Care Network558 GREENVILLE NC558B69003XR RAD1
VISN 6: VA Mid-Atlantic Health Care Network558 DURHAM NC558B69002XR MRI1
VISN 6: VA Mid-Atlantic Health Care Network558 DURHAM NC558B69001XR PORT CARM1
VISN 6: VA Mid-Atlantic Health Care Network558 GREENVILLE NC558B69000XR US1
VISN 9: VA Mid South Healthcare Network614 MEMPHIS TN614B64009XR US2
VISN 10: VA Healthcare System of Ohio506 ANN ARBOR, MI506B60008XR US7
VISN 10: VA Healthcare System of Ohio539 CINCINNATI, OH539B60004XR US2
VISN 10: VA Healthcare System of Ohio583 INDIANAPOLIS IN583B60006XR US1
VISN 10: VA Healthcare System of Ohio655 SAGINAW MI655B60004XR US3
VISN 10: VA Healthcare System of Ohio655 SAGINAW MI655B60006XR US2
VISN 15: VA Heartland Network657 ST. LOUIS MO657B60006XR CATH LAB1
VISN 16: South Central VA Health Care Network586 JACKSON MS586B60002XR CT1
VISN 16: South Central VA Health Care Network586 JACKSON MS586B60001XR IR1
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B60111XR IR1
VISN 19: VA Rocky Mountain Network554 DENVER, CO554B60007XR US1
VISN 19: VA Rocky Mountain Network554 DENVER, CO554B60006XR US1
VISN 19: VA Rocky Mountain Network554 DENVER, CO554B60002XR US1ORDER CANCELLED
VISN 19: VA Rocky Mountain Network554 AURORA CO554B60009XR US1

Q&A

HTME VISNStationEQ POEquipment TypeEquipment QuestionsGovt Equipment Response
VISN 1: VA New England Healthcare System523 WEST ROXBURY MA523B51012XR USCan the minimum monitor size be updated to 19 inches to increase competition?

Can the minimum monitor active size be updated to 19 inches to increase competition?

Can the minimum monitor display size be updated to 19 inches to increase competition?

Can the minimum image storage but changed to 500gb to increase competition?

What will 4D be used for and can it be moved to added value?

Can the maximum product weight be expanded to 200lbs to increase competition?

Image Fusion Software. Please confirm what procedures will be performed utilizing Fusion.

If Fusion is required, will you be utilizing a 3rd party Fusion solution or desiring an all-inclusive Fusion system?

If utilitizing a 3rd party, which navigation system is currently in use?

If Fusion is required, will it be needed for TP, TR, of both?

If Fusion is required, will it be required to be freehand or stabilized?

If Fusion is required, will you need endfire, sidefire, or both?

If Fusion is required, please identify probe requirements and quantities.

If TP is required, please add Bi-plane probe.

See updated Tech Specs and Matrix

Minimum monitor size is 19 inches

Minimum image storage is 500GB

4D removed from requirement

Maximum product weight is not specified

Image Fusion Software is not required but Image fusion capability on the ultrasound would be helpful for MRI–ultrasound correlation during intracranial tumor cases, particularly for initial localization and intraoperative orientation. This has been included in the Added Value section.

VISN 10: VA Healthcare System of Ohio506 ANN ARBOR, MI506B60008XR USC.1 Does the site only want self-paced training and no on-site training?Correct. The use of these ultrasounds will span several different departments and shifts, making on-site training impractical.
VISN 10: VA Healthcare System of Ohio506 ANN ARBOR, MI506B60008XR USG. Please clarify transducers to be traded in (manufacturer and system it belongs to).Model C60X/5-2 and P21X/5-1 are both Boston Scientific transducers that work with the EDGE device. The remaining transducers are Mindray transducers with the 6 TE7 ultrasounds.
VISN 10: VA Healthcare System of Ohio506 ANN ARBOR, MI506B60008XR USG. Please clarify what kind of product the Boston Scientific Corp is ?The Boston Scientific Ultrasound is the EDGE model with two transducers (C60X/5-2, P21X/5-1)
VISN 10: VA Healthcare System of Ohio539 CINCINNATI, OH539B60004XR USAfter speaking with the supervisor last month, he told me that they were hoping to purchase three systems, the matrix only is showing two systems, can you please confirm the total number of systems to be purchased?This requirement is for 2x ultrasound devices
VISN 10: VA Healthcare System of Ohio539 CINCINNATI, OH539B60004XR USThe matrix does not show any endovaginal transducers listed, and the supervisor said they do these frequently, do you want to include endovaginal transducers with these systems?Added additional line to reflect requirement for curvilinear endovaginal transducer
VISN 10: VA Healthcare System of Ohio539 CINCINNATI, OH539B60004XR USCan you please confirm the need for wireless 2-in-1 transducers as we do not offer this product?Reference to 2-in-1 wireless probe removed from Requirement Section; Wireless probe still referenced in Value Added Section
VISN 10: VA Healthcare System of Ohio539 CINCINNATI, OH539B60004XR USThe supervisor also told me that they wanted to purchase the high frequency small parts probe (mL26-8 mHz) for superficial imaging, can you please confirm this transducer as well?Added additional line to reflect requirement for both wideband (<10 MHz) and high-frequency (>15 MHz) linear probes
VISN 10: VA Healthcare System of Ohio539 CINCINNATI, OH539B60004XR US5.a please clarify the frequency of the linear probe neededAdded additional line to reflect requirement for both wideband (<10 MHz) and high-frequency (>15 MHz) linear probes
VISN 10: VA Healthcare System of Ohio539 CINCINNATI, OH539B60004XR US5.b. Please clarify the frequency of the curved probe needed<7 MHz minimum
VISN 10: VA Healthcare System of Ohio539 CINCINNATI, OH539B60004XR US5.c Wireless 2-1 probe appears to be a lock out spec, please move to value add sectionReference to 2-in-1 wireless probe removed from Requirement Section; Wireless probe still referenced in Value Added Section
VISN 10: VA Healthcare System of Ohio539 CINCINNATI, OH539B60004XR USG. Please clarify probes to be traded in with system if anyNone
VISN 10: VA Healthcare System of Ohio655 SAGINAW MI655B60004XR US5.l Can the Phanom requirement be moved to the value-add section or removed?Move to value added
VISN 10: VA Healthcare System of Ohio655 SAGINAW MI655B60004XR USRequest item 1.i. Minimuim Battery life of 480 min be reduced to 60 min.

Request item 1.k. Maximum equipment weight of 240 lbs increased to 255 lbs.

Can you verify that item 7.b. Dedicated 2MHz CW Probe is required for a Radiology Dept?

Can you verify if a Linear for Samll Parts is required?

Do you have any Trade-in Systems?Tech specs updated Trade in systems are listed out in the Tech Spec
VISN 10: VA Healthcare System of Ohio655 SAGINAW MI655B60004XR USClinical Capabilities: You do not request cardiac imaging but are asking for an X5-1. Please clarify.Tech specs updated
VISN 10: VA Healthcare System of Ohio655 SAGINAW MI655B60004XR USWould they need C5-1 transducers? They also need and L1-3 for vascular.Tech specs updated
VISN 10: VA Healthcare System of Ohio655 SAGINAW MI655B60006XR USRequest item 1.i. Minimuim Battery life of 480 min be reduced to 30 min.
Request item 1.k. Maximum equipment weight of 240 lbs increased to 245 lbs.Aceptable for Both
VISN 10: VA Healthcare System of Ohio655 SAGINAW MI655B60006XR USLocal rep communications over time with them is they only want a 2D Echo system, and is all that required. Is 3D Echo now a requirement of this system and should be quoted? The matrix suggests that ‘’Echo unit is intended to be used during diagnostic Cardiography cases to diagnose various heart diseases and abnormalities. The most common procedure this unit will be used for is interdepartmental Echo Cardiography cases.’’ . If 3D is required, is it for transthoracic or transesophageal? Or will a 3D TEE suffice?We are working under the assumption that the new Cardiologist will want 3D for transthoracic and transesophageal. So please quote as appropriate.
VISN 10: VA Healthcare System of Ohio655 SAGINAW MI655B60006XR USSmall Parts and Urology was not a part of discussions with local rep/end-users. This would require quoting a different product/solution than previously discussed. Please advise if these requirements should be quoted or removed.Quoted
VISN 15: VA Heartland Network657 ST. LOUIS MO657B60006XR CATH LABSome of the information states this room is going to be used for Structural Heart. Will you require specialized software or a cardiac ultrasound machine with this bid?No cardiac ultrasounds or specialized software is being requested.Tech spec not updated
VISN 15: VA Heartland Network657 ST. LOUIS MO657B60006XR CATH LABThe matrix is referencing a lateral gantry. Are you requesting a biplane configuration? Other parts of the document state single plane. Seeking clarification.Single Plane only. Tech spec not updated
VISN 15: VA Heartland Network657 ST. LOUIS MO657B60006XR CATH LABUnit Physical specifications Line 28-31 1G-J. Specifications refer to Lateral gantry plane. Please clarify is the request for a Single Plane or a Bi-plane Angiography system?Single Plane only. Tech spec not updated
VISN 15: VA Heartland Network657 ST. LOUIS MO657B60006XR CATH LABUnit Physical specifications Line 48 1AA. Please provide CAD drawings for this space -- the control room, equipment room and the exam room, to clarify the weight.Equipment only, max system weight indicated at 4000 lbs
VISN 15: VA Heartland Network657 ST. LOUIS MO657B60006XR CATH LABAdditional Specifications Line 53 2D. Please clarify if the requirement calls for quoting a Biplane System?Single Plane only. Tech spec not updated
VISN 15: VA Heartland Network657 ST. LOUIS MO657B60006XR CATH LABAdditional Specifications Line 69 2T. Please clarify the requirement/preference for the Hemodynamics system? OR clarify if OEM supplied monitoring system would be adequate?.Hemodynamics compaitiblity with current system is necessary. Tech spec not updated
VISN 15: VA Heartland Network657 ST. LOUIS MO657B60006XR CATH LAB1.n. Please change the Radiographic range to 40Kv - 125 kV to be more vendor inclusive.
1.r. Please change the minimum monitor size to 19" to be more vendor inclusive.1.n On Tech Spec is patient load capacity, this question does not allign with tech spec.

1.r On Tech Spec is kV Range, the question does not allign with tech spec.

Corresponding lines in Tech Spec updated for monitor size and kV Range.

VISN 16: South Central VA Health Care Network586 JACKSON MS586B60001XR IRTechnical Requirements Line 23 1B. Please confirm that an image Intensifier 9 cm is for a ceiling system?Ceiling mounted is designated in 2a. The unit of measure for 1b is inches. Minimum size is 9"
VISN 16: South Central VA Health Care Network586 JACKSON MS586B60001XR IRAdditional Specifications Line 39 2H. Is there sufficient space, air flow and electrical for a Full Load UPS(Example EATON 93) to maintain full functionality during a power outage?A minimum UPS is requested for safe shutdown and/or bridging gap for facility backup power
VISN 16: South Central VA Health Care Network586 JACKSON MS586B60001XR IRAdditional Specifications Line 43 2L. Should the OEM include a quote for a Philips or Boston IVUS system?Either is acceptable, Philips preferred
VISN 16: South Central VA Health Care Network586 JACKSON MS586B60001XR IRAdditional Specifications Line 44 2M. Should the OEM included a Hemodynamics monitoring system in the quotation?Yes, as an option only. Item has been moved to added value
VISN 16: South Central VA Health Care Network586 JACKSON MS586B60001XR IRSoftware Requirements Line 46 3A. Is Cone Beam/3d imaging a requirement or an Option?Make as an Option.Item has been moved to added value
VISN 16: South Central VA Health Care Network586 JACKSON MS586B60002XR CTAdditional Specifications Line 39 2F. Please clarify if a FULL UPS is needed or the minimum time for safe shut down. Will there be a separate room that will accommodate the size of a FULL UPS. along with electrical and HVAC?Specification is for minimum UPS for safe shutdown and/or bridging gap for facility backup power.
VISN 16: South Central VA Health Care Network586 JACKSON MS586B60002XR CTWorkstation Requirements Line 42 3A. Please clarify if a FULL UPS is needed or the minimum time for a safe shutdown. Will there be a separate room that will accommodate the size of a FULL UPS along with electrical and HVAC?Specification is for minimum UPS for safe shutdown and/or bridging gap for facility backup power.
VISN 16: South Central VA Health Care Network586 JACKSON MS586B60002XR CTWorkstation Requirements Line 43 3B. Please clarify if a FULL UPS is needed or the minimum time for a safe shutdown. Will there be a separate room that will accommodate the size of a FULL UPS along with electrical and HVAC?Specification is for minimum UPS for safe shutdown and/or bridging gap for facility backup power.
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B60111XR IRFor Trade in Section: please confirm original manufacturing date or install date for accurate trade in valuationAll the information required is provided in the trade in section of the technical specifications document
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B60111XR IRPlease confiem whether the Xray tude has been replace during the life of the systemIt has not been replaced
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B60111XR IRUPS: Please confirm whether the intent is the maintain system operation during transfer to facility e-power, or to profide full battery-only operation for the entire 60 minute duration.Must at least maintain system operation during transfer to facility e-power. Updating to minimum 10min
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B60111XR IRUPS: Please clarify the intended definition of "full functionality" (e.g. continuous xray acquisition versus system control and image review during transition to facility e-power).Must at least maintain system operation during transfer to facility e-power. Updating to minimum 10min
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B60111XR IRAdditional Specifications Line 37 2E. Integrated System Shielding. Would this be a table rad shield and hanging rad shield? Or is this EP shielding, which helps with the internal electrograms?“integrated system shielding” means the radiation protection is built into the imaging/table system itself as one coordinated unit, rather than relying only on separate ceiling‑mounted shields and personal lead aprons.
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B60111XR IRAdditional Specifications Line 38 2F. Operator console. How much memory is required?Minimum of about 500,000 images at 512×512 matrix stored on the operator console.
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B60111XR IRAdditional Specifications Line 40 2H. Please clarify if a FULL UPS is needed or the minimum time for safe shut down. Will there be a separate room that will accommodate the size of the FULL UPS, Electrical and Air flow?Full UPS is needed, there is space to accommodate.
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B60111XR IRAdditional Specifications Line 42 2J. Please clarify the injector requested; is a floor or ceiling injector an adequate substitution?No, table-mounted only
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B60111XR IRAdditional Specifications Line 45 2M. Should the OEM include a Hemodynamics monitoring system in the quotation?No, we already have one
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B60111XR IRAdditional Specifications Line 48 2O. This is a lock out specification. Please remove or move to added value.No, dual‑axis rotational coronary angiography is a necessary and common feature
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B60111XR IRAdditional Specifications Line 50 2Q.Please clarify the injector requested; is a floor or ceiling injector an adequate substitution?No, table-mounted only
VISN 17: VA Heart of Texas Health Care Network674 TEMPLE TX674B60111XR IR2h. Please change to Full UPS with a runtime of less than 20 minutes, as this a normal run time at 80-100% load.Yes, changing to minimum 10min
VISN 19: VA Rocky Mountain Network554 AURORA CO554B60009XR USRequest item 1.g. Minimum battery life of 120 min be reduced to 60 min.

Request item 1.i. Maximum equipment weight of 110 lbs be increased to 165 lbs.

Can you verify if item 9.g. Integration to Dose Tracking System is required? Minimum battery life not changed Maximum equipment weight not changed Integration to dose tracking system is required VISN 19: VA Rocky Mountain Network 554 DENVER, CO 554B60002 XR US Is a phased/cardiac probe needed?

Can you verify if item 6.e. is this required as there is no 3D probe?

Can you verify if 8. 4D advanced features are required as there is no 4D Probe?ORDER CANCELLED
VISN 19: VA Rocky Mountain Network554 DENVER, CO554B60002XR US4D tools are requested but did not request a specific 3d/4d transducer. Can you confirm that a 3d/4d transducer is needed?ORDER CANCELLED
VISN 19: VA Rocky Mountain Network554 DENVER, CO554B60002XR USSection A says there is no trade in, but on section G, they list a trade in. Can you clarify on Trade In?ORDER CANCELLED
VISN 19: VA Rocky Mountain Network554 DENVER, CO554B60006XR USMinimum touchscreen size 12" - Philips has a touch screen of 12". Will a touchscreen of 12" or larger be acceptable?Acceptable
VISN 19: VA Rocky Mountain Network554 DENVER, CO554B60006XR USMaximum dimensions to 75 x 24 x 43 - Philips maximum dimensions are 75x24x43. Will a device with the dimensions of 75x24x43 be acceptable?Acceptable
VISN 19: VA Rocky Mountain Network554 DENVER, CO554B60006XR USMaximum equipment weight to 240 - Philips maximum equipment weight is 240. Will a device with an equipment weight of 240lbs be acceptable?Acceptable
VISN 19: VA Rocky Mountain Network554 DENVER, CO554B60006XR USAre AI Optimization tools required, or can they be moved to Added Value?Spec moved to added value
VISN 19: VA Rocky Mountain Network554 DENVER, CO554B60006XR USCan the minimum monitor size be updated to 19 inches to increase competition?

Can the touchscreen capability be added to value add?

Can the number of split screens be changed to 2 to increase competition?

Can the maximum product weight be expanded to 200lbs to increase competition?

7. a. Matrix linear: Can the upper frequency range be reduced to 14 MHz to increase competition?

7. b. Linear: Can the upper frequency range be reduced to 18 MHz to increase competition?

8. AI optimization tools - what procedures will this be used for? Can this be added to value add?

Clinical Training - Technologists who complete the clinical applications training should receive (CMEs) - Can this be a value add? 19 in minimum monitor size is acceptable Touchscreen capability is required Number of split screens changed to 2 Maximum product weight not changed Matrix linear upper frequency not changed Linear upper frequency not changed AI optimization moved to value add Clinical Training CMEs acceptable as value add

VISN 19: VA Rocky Mountain Network554 DENVER, CO554B60007XR US1.i, Can the max weight be increased to 176 lb to increase competition?Maximum equipment weight requirement changed to 176 lbs
VISN 19: VA Rocky Mountain Network554 DENVER, CO554B60007XR US5.n, p, q Are the scans along tutorials for Anesthesia, vascular acess and acute care clinically necessary or can they be moved to value add section?Scan-along tutorials moved to Added Value
VISN 19: VA Rocky Mountain Network554 DENVER, CO554B60007XR USRequest for item 5.b. include Electronic Gain control on the display.
Item 5.n, 5.p, and 5.q Scan Along tutorials are restrictive.5.b to specify that the system shall have user-adjustable gain control with electronic indication on the display (e.g., numeric value and/or graphical bar), in addition to the existing physical gain control. This is considered part of the required functionality

To clarify, Items 5.n, 5.p, and 5.q are value-add features

VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63002XR CATH LAB1.a Please consider updating the PA gantry RAO projection rotation 0-1800 to promote fair participation.Updated specification
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63002XR CATH LAB1.e Please consider updating the required specification to 90-1200 to promote fair participationUpdated specification
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63002XR CATH LAB1.g Please consider updating the required specification to CRA 45° to CAU 45° 0 to promote fair participationSpecification removed, see lines 65 and 66
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63002XR CATH LAB1.h Please consider updating the required specification to 29.7" to 41.5" to promote fair participationUpdated specification to 29.7" to 41.5"
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63002XR CATH LAB1.j Please consider updating the required specification to 550lbs to promote fair participationUpdated specification to 550lbs
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63002XR CATH LAB1f and 1g: The requirement mentions lateral gantry (this is a single plane system). Please clarify.Request is for single plane. Removing specification.
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63002XR CATH LAB2d. The requirement mentions lateral gantry again (this is a single plane system). Please clarify.Request is for single plane. Removing specification.
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63002XR CATH LABPlease verify Trade-In details, Information provided suggested trade of system installed in 2024This is correct
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63002XR CATH LABThe trade-in is listed as a 2024 Azurion 7M12. Is this the correct asset?This is correct
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63003XR IR1.a Please consider updating the minimum required detector size 30 x 40 to promote fair participation.Updated specification
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63003XR IR1.b Should this be removed as today industry standardization is with flat panel detectors and not Image intensifiers.Removed specification
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63003XR IR1.k Is VA Albany requesting integration with an existing IVUS or a new IVUS ultrasound system?New IVUS system
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63003XR IR1a – Please clarify the minimal detector size of 50cmx50cm. Note: no vendor offers this specification.Updated to 30x40, see line 69
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63003XR IRThis station has an IR lab on the FY25 September Turnkey (528B53026).
Is 528B63003 a re-solicitation or an incremental lab?This is for an additional IR lab at the facility
VISN 2: VA Healthcare Network Upstate New York528 ALBANY NY528B63003XR IR1b - Image intensifier II (?). Please clarify this specification.Removed specification, see line 70
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B62001XR IS1.k. Can the depth be opened up to 38" (just a 2" increase) to increase competition?Yes, depth can be opened to 38".
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B62001XR IS8a. Is Prostate Gland volume and edge boundaries computation capabilities clinically necessary for Pain Management?Yes. This is a feature for Fusion-Targeted Biopsy a request from serviceline
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B62001XR IS5.q. Can integtated DVR capabilities be moved to a Value-Add section?No, this is a needed specification
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B62004XR US1.i. Can the # of transducer ports be reduced to 4 (decrease of 1) to increase competition?Yes, the number of transducer ports can be reduced to 4.
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B62004XR US1.k. Can the depth be opened up to 38" to increase competition?Yes, depth can be opened to 38".
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B62004XR US1.l. Can the max weight be increased to 176 (increase of 11 lbs) to increase competition?Yes, weight can be increased to 176 lbs.
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B62004XR US4.c. Can the Customizable Slider Set Up for Touchscreen be moved to a Value-Add section?Yes, customizable slider set up for touchscreen can be moved to value-add section.
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B62004XR US5.q. Can integtated DVR capabilities be moved to a Value-Add section?No, this is a needed specification
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B62004XR US8a. Is Prostate Gland volume and edge boundaries computation capabilities clinically necessary for Pain Management?Yes. This is a feature for Fusion-Targeted Biopsy a request from serviceline
VISN 4: VA Stars & Stripes Healthcare Network646 PITTSBURGH PA646B62004XR USRequest item 1.l. Maximum equipment weight increased from 165 lbs to 190 lbs.

Can you verify if the Transducer Frequencies are correct for the Sector Phased Array, Single Crystal Matrix, and 2D Matrix Array?

4D is required however, no 4D Transducers are listed - can you verify if this is required?

Yes, weight can be increased to 190 lbs. Yes, transducer frequencies are correct.
VISN 5: VA Capitol Health Care Network512 BALTIMORE MD512B60604XR HYBRID1.n Please confirm that this is an IR lab without combination of full service CT?Confirmed – no CT
VISN 5: VA Capitol Health Care Network512 BALTIMORE MD512B60604XR HYBRID1.h Please consider replacing 50 with 30 to promote fair participation.1.h? If this is referring to 2.h specification then this is clinically necessary and two or more vendors can meet
VISN 5: VA Capitol Health Care Network512 BALTIMORE MD512B60604XR HYBRID2.i Please consider updating spec to 1200 to promote fair participation.2.i This is clinically necessary and two or more vendors can meet
VISN 5: VA Capitol Health Care Network512 BALTIMORE MD512B60604XR HYBRID2.j Please consider updating spec to 900 to promote fair participation.2.j This is clinically necessary and two or more vendors can meet
VISN 5: VA Capitol Health Care Network512 BALTIMORE MD512B60604XR HYBRID2.l Please consider updating spec to +/- 45 to promote fair participation.2.l This is clinically necessary and two or more vendors can meet
VISN 5: VA Capitol Health Care Network512 BALTIMORE MD512B60604XR HYBRID2.s Please consider updating spec to promote fair participation.2.s This is clinically necessary and two or more vendors can meet
VISN 5: VA Capitol Health Care Network512 BALTIMORE MD512B60604XR HYBRID3.n Please consider removing spec to promote fair participation, as this is vendor specific.3.n This is clinically necessary and two or more vendors can meet
VISN 5: VA Capitol Health Care Network512 BALTIMORE MD512B60604XR HYBRID6.a Please consider updating spec to +/- 45 to promote fair participation.6.a This is clinically necessary and two or more vendors can meet
VISN 5: VA Capitol Health Care Network512 BALTIMORE MD512B60604XR HYBRID6.g Please consider removing spec to promote fair participation, as this is vendor specific.6.g This is clinically necessary and two or more vendors can meet
VISN 5: VA Capitol Health Care Network512 BALTIMORE MD512B60604XR HYBRIDPlease provide CAD drawings of the room to include ceiling height.This will be new construction, so no CAD drawings are available
VISN 5: VA Capitol Health Care Network512 BALTIMORE MD512B60604XR HYBRIDGeneral Hardware Specifications: Will any other modalities be used concurrently potentially limiting system movement within the room?

General Hardware Specifications: Are there any uptime guarantee requirements or constraints to Preventive maintenance?

General Hardware Specifications: Is the ceiling area free from cabling to allow for full system movement of robotic arm?

General Software Specifications: Is 3D imaging needed from multiple sides or just headend?

General Software Specifications: Is large volume visualization of up to ten vertebrae simultaneously or offering coverage of thorax, abdomen, or pelvis with a volume diameter of 43 cm needed?

General Software Specifications: Is a fixed isocenter of the system required regardless of table angulation or table height?1.No
2.No
3.No
4.Multiple sides
5.Yes
6.Yes
VISN 5: VA Capitol Health Care Network512 BALTIMORE MD512B60604XR HYBRID3.a. This is not something that is possible to acquire in the Vascular surgery space. Please ask to remove. This is more of an electrophysiology request.

6.d. Please remove ceiling mounted specification for fair competition. 3a. This is clinically necessary and two or more vendors can meet

6d. This is clinically necessary and two or more vendors can meet VISN 5: VA Capitol Health Care Network 540 CLARKSBURG WV 540B61004 XR MRI What coils will be included with trade in? Please send a full list Body 18 (Qty 2) Flex Lg 4 Flex Sm 4 Foot / Ankle 16 Head /Neck 20 Peripheral Ango 36 Shoulder Lg 16 Shoulder Sm 16 Special Purpose 4 Spine 22 TrxRx CP Head TxRx Knee 15

VISN 5: VA Capitol Health Care Network540 CLARKSBURG WV540B61004XR MRIWhat type of batteries do you prefer? VRLA or LithiumLithium
VISN 5: VA Capitol Health Care Network540 CLARKSBURG WV540B61004XR MRIWould a floor model injector be acceptable?Floor/pedestal mount injector is acceptable if cords are routed through the penetration panel to prevent tripping hazard. Battery-powered injectors are acceptable as well if dock can be placed in acceptable location.
VISN 5: VA Capitol Health Care Network540 CLARKSBURG WV540B61004XR MRI3e. Is a full system UPS required or a UPS for the scan console only? Please change UPS runtime to 6 minutes.

3q. Please change to pedestal- mounted injector, which is the norm for MR.

Trade-in: is the current system 8 or 16 channels? 3e. Full 3q. Floor/pedestal mount injector is acceptable if cords are routed through the penetration panel to prevent tripping hazard. Battery-powered injectors are acceptable as well if dock can be placed in acceptable location.

Trade-in: 48 channel VISN 6: VA Mid-Atlantic Health Care Network 558 DURHAM NC 558B69002 XR MRI Trade-in Line 178. Please clarify the type, number of coils and channel count. Also please provide the gradient strength and channel count for the system being traded in 1.5T Philips Ingenia. dStream FootAnkle 8‑Channel Coil: Designed for both 1.5 T and 3.0 T systems.Offers 8 integrated channels.Features a ski‑boot-like form factor providing either a large field‑of‑view for the entire foot or a small FOV for high-resolution ankle imaging. dStream Head/Neck Coil (Ingenia 1.5T): The dStream HeadNeckSpine integrated coil offers:

20 channels for head/neck imaging. Enables up to 52 channels for full neuro coverage (head, neck, spine). Stream Knee 16‑Channel Coil: The primary knee coil offered is the dStream Knee 16ch coil, supporting 16 channels.It features two overlapping rings of eight coil elements each, providing extensive coverage, high SNR, and enhanced parallel imaging via dS SENSE. dStream Wrist 8‑Channel Coil: Designed for high-resolution imaging of the wrist (and hand).

Offers 8 channels, fits left or right wrist, features a hinged design for easy setup and a rigid base plate to reduce motion. dStream Shoulder 16‑Channel Coil:Provides high image quality and signal uniformity throughout the shoulder, with excellent penetration into the labrum. Base plate and adjustable anterior part can be positioned for comfortable imaging of either the left or right shoulder. Philips dStream Ring Coil: Channels: 8‑channel design. 33 mT/m gradient amplitude.

VISN 6: VA Mid-Atlantic Health Care Network 558 DURHAM NC 558B69002 XR MRI Trade-in: What is being replaced a 1.5T or 3T?

1.g Please change maximum system dimensions to 100x100x100 for fair competition.

3.f. Is a full system UPS or a console- only UPS required? Please change run time to 7 minutes.

3.I Please change to active shielding, as is industry standard.1.5T. We will make the necessary changes.
VISN 6: VA Mid-Atlantic Health Care Network558 GREENVILLE NC558B69000XR US1.c. Can the max weight be increased to 176 (increase of 11 lbs) to increase competition?The max weight requirement will remain at 165 lbs, as this suppports workflow efficiency, maneuverability, and safe trasnport between facilities. Increasing the weight would negatively impact portability and usability.
VISN 6: VA Mid-Atlantic Health Care Network558 GREENVILLE NC558B69000XR USCan the maximum product weight be expanded to 200lbs to increase competition?The max weight requirement will remain at 165 lbs, as this suppports workflow efficiency, maneuverability, and safe trasnport between facilities. Increasing the weight would negatively impact portability and usability.
VISN 6: VA Mid-Atlantic Health Care Network558 GREENVILLE NC558B69003XR RADCan the wall detector be changed to wireless OR fixed detector with sizing 17x17. Fixed will allow less drops and full capacity of detector size at 17x17

Please confirm wireless detector is minimum 14x17?

Can the maximum pixel size be changed to 140 µm pixel pitch to accommodate more vendors?

Can the minimum patient table load capacity (static) be lowered to 660 to accommodate more vendors?

Can the minimum table height from floor be lowered to 21 inches to accommodate more vendors?

1. Due to clinical need, the wall detector will need to be wireless to provide flexibility, improve workflow, and ability to image beyond wall stand.

2. The Minimum wall detector size will be edited on the tech specs to reflect 14 x 17 as the minimum.

3. We would like to keep as 100 µm.

4. Due to potential bariatric cases,we would like to keep the weight limit at 700lbs.

5. We are will to increase table height to a minimum of 20 inches, but will not exceed that limit.

VISN 6: VA Mid-Atlantic Health Care Network558 GREENVILLE NC558B69004XR USThe matrix was labeled as ultrasound but the configuration is for an x-ray system. Please clarify.This requirement is for an X-Ray system, not an ultrasound.
VISN 6: VA Mid-Atlantic Health Care Network558 GREENVILLE NC558B69004XR USSpecs look to be for XR RAD not XR US, please confirm equipment typeThis requirement is for an X-Ray system, not an ultrasound.
VISN 6: VA Mid-Atlantic Health Care Network652 RICHMOND VA652B59013NM GAMMA CAMERA1b. Please amend to 60-170 to allow full and fair competition. There are no isotopes scanned below 60 keV anyway.

1d. Please amend to 1800 lbs to allow full and fair competition 2f. Please remove to allow full and fair competition. Only one system on the market can meet this specification.

4a. Please amend to 19” to allow full and fair competition 4k. Please remove to allow full and fair competition. Only one vendor can meet this specification. 1b. Amend 60-170 1d. ok to amend to 1800lbs 2f. Do not agree, keep 4a. Ok 4k. Do not agree. Keep as is.

VISN 9: VA Mid South Healthcare Network 614 MEMPHIS TN 614B64009 XR US Request 1.i. Minimium Battery Life of 45 min be reduced to 30 min. Yes, time has been edited to reflect a minimum of 30 minutes for battery life instead of the 45.

File details come from the government source that posted it. Updated .