CONVENTIONS
ELECTRICAL LEGEND
ABBREVIATIONS
S
M
MP
XP
MC
D a
WP
RC
P
K
MOUNTING HEIGHT 18" UNLESS NOTED OTHERWISE
DUPLEX RECEPTACLE - 20A., 125V. - TAMPER RESISTANT
F
J J
T
R
M
M
C
C
B
GFI
A
3 5
A
3 5
SHEET NUMBER WHERE DETAIL IS SHOWN
DETAIL NUMBER
SHEET NUMBER WHERE DETAIL IS TAKEN
REVOLUTION PER MINUTE
ROOT MEAN SQUARE
POLYVINYL CHLORIDE
POUNDS PER SQUARE INCH
POWER FACTOR
PUSH BUTTON
POLE (1P., 2P., 3P.)
OVERHEAD
ON CENTER
NORMALLY OPEN
NUMBER
NIGHT LIGHT
NOT IN CONTRACT
NON-FUSED
NATIONAL ELECTRICAL CODE
NORMALLY CLOSED
MOUNTED
MOTOR OPERATED DAMPER
MAIN LUGS ONLY
MISCELLANEOUS
MINIMUM
MOUNTING HEIGHT
MANHOLE
MOTOR GENERATOR
THOUSAND CIRCULAR MILS
MOTOR CONTROL CENTER
MAXIMUM
MASTER ANTENNA TELEVISION
LIGHTING
LOCKED ROTOR AMPERES
LINEAR FEET
KILOWATT HOURS
KILOWATTS
KILO-VOLTS-AMPERES
KILO-VOLTS
JUNCTION BOX
INTERMEDIATE METAL CONDUIT
HERTZ
HIGH PRESSURE SODIUM
HORSEPOWER
HAND-OFF-AUTOMATIC
HIGH INTENSITY DISCHARGE
RPM
RMS
PVC
PSI
PF
PB
P
OH
O/C
N.O.
NO., #
NL
NIC
NF
NEC
NC
MTD
MOD
MLO
MISC
MIN
M.H.
MH
MG
KCMIL
MCC
MAX
MATV
LTG
LRA
LF
KWH
KW
KVA
KV
JB
IMC
HZ
HPS
HP
HOA
HID
E
SYMBOL DESCRIPTION
LIGHTING FIXTURE - FLUORESCENT - TYPE AS INDICATED
LIGHTING FIXTURE - CEILING, WALL MOUNTED, DIRECTIONAL
- TYPE AS INDICATED
LIGHTING FIXTURE ON EMERGENCY OR NIGHT LIGHT CIRCUIT
LOW VOLTAGE, D.C., EMERGENCY WIRING SYSTEM
- 2#10-3/4"C., UNLESS OTHERWISE NOTED
EXIT LIGHT - CEILING, WALL MOUNTED - SHADED AREA
INDICATES ILLUMINATED FACE - PROVIDE
DIRECTIONAL ARROWS AS INDICATED
- WALL MOUNTING HEIGHT 7'-6"
SWITCH - SINGLE POLE, DOUBLE POLE, THREE WAY, FOUR
WAY, SUBSCRIPT DENOTES OUTLETS CONTROLLED
- MOUNTING HEIGHT 4'-0"
SWITCH - KEY OPERATED, WITH PILOT LIGHT, REMOTE
CONTROL, WEATHER PROOF - MOUNTING
HEIGHT 4'-0"
SWITCH - MOMENTARY CONTACT, DOOR OPERATED,
EXPLOSION PROOF - MOUNTING HEIGHT 4'-0"
DOUBLE DUPLEX RECEPTACLE - 20A., 125V. - MOUNTING
HEIGHT 18" UNLESS NOTED OTHERWISE
JUNCTION BOX - CEILING, WALL MOUNTED - SIZE PER NEC
OR AS INDICATED
DISCONNECT SWITCH - FUSED, NON-FUSED - TYPE AND
RATING AS INDICATED
MAGNETIC STARTER, COMBINATION TYPE STARTER - TYPE
AND RATING AS INDICATED
MANUAL MOTOR STARTER, H.P. RATED SWITCH, H.P. RATED
SWITCH WITH PILOT LIGHT - MOUNTING
HEIGHT 4'-0" - TYPE AND RATING AS REQUIRED
CONTACTOR, RELAY - TYPE AS INDICATED OR REQUIRED
ELECTRIC HEAT TRACING
CONTROL DEVICE - TYPE AS NOTED
MOTOR - HORSEPOWER AS NOTED
TRANSFORMER - DRY TYPE - RATING AS INDICATED
A
A/C
AC
ACU
AFF
AFG
AHU
AIC
AL
ATS
AUX
BKR
C
CAB
CAT
CB
CCTV
CLF
CLG
C
L
CU
CX
DC
DISC
DN
DWG
EC
EF
EMT
EX
F
FA
FCU
FDR
FLA
FLEX
FR
FUT
GA
GEN
GFI
GRD
RX
SEC
SF
S/N
SPECS
SQ
SW
SWBD
SWGR
SYM
AMPERE
AIR CONDITIONER
ALTERNATING CURRENT
AIR CONDITIONING UNIT
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AIR HANDLING UNIT
AMPERES INTERRUPTING CAPACITY
ALUMINUM
AUTOMATIC TRANSFER SWITCH
AUXILIARY
BREAKER
CONDUIT
CABINET
CATALOG
CIRCUIT BREAKER
CLOSED CIRCUIT TELEVISION
CURRENT LIMITING FUSE
CEILING
CENTER LINE
COPPER
CONNECT TO EXISTING
DIRECT CURRENT
DISCONNECT
DOWN
DRAWING
EMPTY CONDUIT
EXHAUST FAN
ELECTRICAL METALLIC TUBING
EXISTING
FUSED OR FUSIBLE
FIRE ALARM
FAN COIL UNIT
FEEDER
FULL LOAD AMPERES
FLEXIBLE
FRAME
FUTURE
GAUGE
GENERATOR
GROUND FAULT INTERRUPTER
GROUND
REMOVE EXISTING
SECONDARY
SQUARE FOOT
SOLID NEUTRAL
SPECIFICATIONS
SQUARE
SWITCH
SWITCHBOARD
SWITCHGEAR
SYMMETRICAL
TEL
TV
TYP
UG
UH
UL
UPS
V
W
W/
WP
XFMR
TELEPHONE
TELEVISION
TYPICAL
UNDERGROUND
UNIT HEATER
UNDERWRITERS LABORATORIES
UNINTERRUPTED POWER SUPPLY
VOLTS
WATTS
WITH
WEATHERPROOF
TRANSFORMER
DUPLEX RECEPTACLE - 20A., 125V. - MOUNTING HEIGHT
18" UNLESS NOTED OTHERWISE
SINGLE RECEPTACLE - 20A., 125V. - MOUNTING HEIGHT
GFI RECEPTACLE - 20A., 125V. - MOUNTING HEIGHT
18" UNLESS NOTED OTHERWISE
18" UNLESS NOTED OTHERWISE
SPLIT CIRCUIT RECEPTACLE - 20A., 125V. - MOUNTING
HEIGHT 18" UNLESS NOTED OTHERWISE
SHEET NUMBER WHERE SECTION IS CUT
SHEET NUMBER WHERE SECTION IS SHOWN
SECTION CUT
SECTION LETTER
DETAIL
CONDUIT TERMINATED IN BUSHING
CONDUIT SEAL
CONDUIT - TURNING UP OR DOWN AS REQUIRED
CONDUIT - EXISTING
HOMERUN TO PANEL - NUMBER OF ARROWS INDICATE
CONDUIT - IN OR UNDER FLOOR
CONDUIT - IN OR ON CEILING OR WALLS
GROUP MOUNTED EQUIPMENT - TYPE AS NOTED
SPECIAL CABINET - TYPE AS NOTED
TO TOP
PANELBOARD - TYPE AS NOTED - MOUNTING HEIGHT 6'-6"
ENCLOSED CIRCUIT BREAKER
CT CURRENT TRANSFORMER
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR
SPD SURGE PROTECTIVE DEVICE
NUMBER OF CIRCUITS AND NUMBER OF CROSSLINES
INDICATES NUMBER OF #12 PHASE & NEUTRAL
CONDUCTORS - WHERE NO CROSSLINES APPEAR
2#12 CONDUCTORS ARE IMPLIED. GROUND WIRE IS
NOT SHOWN BUT REQUIRED. PROVIDE #12 GROUND
WIRE UNLESS OTHERWISE INDICATED.
F
FIRE ALARM - FLASHING LIGHT
SECURITY CAMERA
14904.010
2/08/2019
- 2/08/2019
FINAL SUBMISSION
FINAL SUBMISSION
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D
The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE DESCRIPTION
TH
E
JO
H
N F
. K
EN
N
ED
Y C
EN
TE
R fo r t he
P
ER
FO
R
M
IN
G A
R
TS
F .S
T, N
W W
A
SH
IN
G
TO
N
, D C
C O
N D
E N
S E
R
W
A T
E
Y S
T E
M
R
E P
A I R
S
J F
K K
T
A S
K
SEAL:
E-001
ELECTRICAL LEGEND,
ABBREVIATIONS AND PANEL
SCHEDULES
TJM
FJL
G p r o je c ts .0 c a d d S u b m is si o n
F in a l\ .0
E .d w g
:3 :2
P M
JR
A
IT
H
L
12x14
12x14 x
12x7 x x x
12x1212x12
(E)CWR
(E)CWS
(E)CWR
(E)CWS
(E)"CWS
E
C
W S
E
C
W S
(E)CWS
24"(E)CWS
20"(E)CWS
E
D
E
D
(E)CWS (E)CWS
REPLACE EXISTING ACTUATORS
W/NEW ELECTRIC ACTUATORS
EXISTING VALVES TO REMAIN
INSTALL NEW 12" CONDENSER
WATER BYPASS PIPING
W/ 2-WAY CONTROL VALVE
12" CWS
CONNECT
TO
EXISTING
CWS
CONNECT
TO
EXISTING
CWR
VAN VAN
VAN VAN
ADDED ADDED ADDEDADDEDADDEDADDED ADDED
M L
M L
M L
M L
M L
S
S
S
S
S
S
S
S
S
S
S
D
O
P
EX SWBD SH-LC-3A,
SEE E-501 FOR ADDITIONAL
INFORMATION
EX SWBD OH-LC-3A1
EX SWBD OH-LC-3A2. SEE E-501
FOR ADDITIONAL INFORMATION.
J
F
F
RENTAL PUMP-2,
150HP MAX,
480V, 3Ø.
RENTAL PUMP-1,
150HP MAX,
480V, 3Ø.
1,000 TON TRAILER MTD RENTAL
COOLING TOWER CT-1. 136 AMPS
MAX, 480V, 3Ø.
RIVER PUMP ROOM PART PLAN.
SEE E-401 FOR WORK IN THIS
AREA.
EX SWITCHBOARD SH-LC-3B.
EX PANEL PH-S2-5 LOCATED
AT 8' ELEVATION.
EX PANEL
LL-S3-7A.
1,000 TON TRAILER MTD RENTAL
COOLING TOWER CT-2, 136 AMPS
MAX, 480V, 3Ø, LOCATED AT THE
PLAZA LEVEL (40' ELEVATION).
DRAWING NOTES: (APPLY TO THIS DRAWING ONLY)
1 JUNCTION BOX SIZED AS REQUIRED BY NEC. MOUNT TIGHT TO
STRUCTURE. FIELD COORDINATE THE EXACT LOCATION (TYPICAL).
2 RENTAL PUMP-1 & PUMP-2 FEEDER. RACK TIGHT TO STRUCTURE
MAINTAINING LEVEL ALONG CONDUIT RUN. SEE ELECTRICAL ONE LINE
FOR ADDITIONAL INFORMATION. ROUTE ALONG WITH MECHANICAL
PIPING.
3 SEE ELECTRICAL ONE LINE FOR ADDITIONAL INFORMATION.
4 COOLING TOWER CT-1, COOLING TOWER CT-2 AND PANELBOARD
LC-17-1A FEEDERS. RACK TIGHT TO STRUCTURE. MAINTAIN LEVEL
ALONG CONDUIT RUN. SEE ELECTRICAL ONE LINE FOR ADDITIONAL
INFORMATION. ROUTE ALONG WITH MECHANICAL PIPING.
5 ROTATE 1X4 WEATHERPROOF FLUORESCENT FIXTURE 90° IN PLACE
TO MAKE ROOM FOR PIPING.
6 KENNEDY CENTER TO RELOCATE EXISTING LIGHT FIXTURE IN FRONT
OF MECHANICAL PIPING. COORDINATE PROJECT PHASING FOR THIS
AREA WITH THE KENNEDY CENTER.
7 KENNEDY CENTER TO RELOCATE EXISTING CAMERA. COORDINATE
PROJECT PHASING FOR THIS AREA WITH THE KENNEDY CENTER.
8 KENNEDY CENTER TO RELOCATE EXISTING FIRE ALARM FLASHING
LIGHT. COORDINATE PROJECT PHASING FOR THIS AREA WITH
KENNEDY CENTER.
9 SEE E-501 FOR EQUIPMENT AT THIS LOCATION.
D E
F G
H J
K L
M N
O P
Q R
S T
D
E
F
G
H
J
K
L
M
N
O
P
E-201
FLOOR PLAN -
PARKING 'B' LEVEL
(17' ELE.) -
ELECTRICAL NEW WORK
FLOOR PLAN - PARKING LEVEL 'B' (17' ELEVATION) - ELECTRICAL NEW WORK
DRAWING SCALE:
" = 1'-0"
14904.010
2/08/2019
- 2/08/2019
FINAL SUBMISSION
FINAL SUBMISSION
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D
The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE
DESCRIPTION
TH
E
JO
H
N F
. K
EN
N
ED
Y C
EN
TE
R fo r t he
P
ER
FO
R
M
IN
G A
R
TS
F .S
T, N
W W
A
SH
IN
G
TO
N
, D C
C O
N D
E N
S E
R
W
A T
S
T E
M
R
E P
A I R
S
J F
K K
T
A S
K
SEAL:
N
0 16' 32' 64' 96'
1/32"=1'-0"
CAUTION:
IF THIS PLAN IS A REDUCTION, GRAPHIC SCALES
MUST BE USED.
GRAPHIC SCALE
TJM
FJL
G p r o je c ts .0 c a d d S u b m is si o n
F in a l\ .0
E .d w g
:3 :2
P M
JR
A
IT
H E L
AutoCAD SHX Text A
INSTALL TRAVELING SCREEN
CONTROLLER WITH EQUIPMENT
FURNISHED.
F F
REMOVE EXISTING STARTERS FOR
TRAVELING SCREEN MOTORS.
PROVIDE 3P-30A FUSED SAFETY
SWITCH FUSED AT 3 AMPS FOR
TRAVELING SCREEN UNIT. MAKE
CONNECTION TO EXISTING BRANCH
CIRCUIT. BRANCH CIRCUIT IS FED
FROM SWITCHBOARD SH-LC-3B.
J
F F
J
EX FSS FOR PUMP SHALL
REMAIN. BRANCH CIRCUIT IS FED
FROM SWITCHBOARD SH-LC-3B.
PUMP
BW1
PUMP
BW2
EX
EX
EX
EX
PUMP SP-1: 7
HP,
480V, 3Ø.
M
AC
UP
C D
E F
G H
J K
L M
N O
P Q
R
1 2 3 4 5 6 7 8 9
DRAWING NOTES:
(APPLY TO THIS DRAWING ONLY)
ADD ALTERNATE #2 TRAVELING SCREEN UNIT, 1HP, 480V, 3Ø. FED FROM SWITCHBOARD SH-LC-3B.
ADD ALTERNATE #2: RX CONNECTION TO MOTOR BACK TO JUNCTION BOX AT MOTOR. EXISTING
MOTOR IS 15HP, 480V, 3Ø.
ADD ALTERNATE #2: PROVIDE VFD IN NEMA 12 ENCLOSURE FOR NEW 15HP, 480V, 3Ø PUMP. PROVIDE
3#10 & 1#10 GROUND WIRE IN
" CONDUIT TO AND FROM VFD AND MOTOR JUNCTION BOX. MAKE ALL
REQUIRED CONNECTIONS TO VFD AND MOTOR.
ADD ALTERNATE #1: VALVE ACTUATOR, 120V, 5 AMPS.
ADD ALTERNATE #1: PROVIDE COMBINATION MOTOR STARTER WITH 3P-30A NFSS, NEMA 1 STARTER, START STOP SWITCH, RED RUNNING PILOT LIGHT AND AUXILIARY CONTACTS AS REQUIRED IN NEMA
12 ENCLOSURE. PROVIDE ALL REQUIRED SUPPORT AND MOUNT AT MOTOR.
5 ADD ALTERNATE #1: 3#12 & 1#12 GROUND IN
" CONDUIT TO EXISTING 1P-20A SPARE CIRCUIT
BREAKER IN PANEL LL-S3-7A LOCATED ON DRAWING E-201.
7 ADD ALTERNATE #1: 3#10 & 1#10 GROUND IN
" CONDUIT TO PANEL PH-S2-5 LOCATED ON DRAWING
E-201. PROVIDE 17.5A CLASS J FUSE EQUAL TO BUSSMANN LPJ IN EXISTING 3P-30A SWITCH.
8 PUMP SP-1, DISCONNECT EXISTING BRANCH CIRCUIT FROM EXISTING 7
" HP, 480V, 3Ø, MOTOR
BEING REMOVED BY MECHANICAL. CONNECT THE EXISTING BRANCH CIRCUIT TO THE NEW
MOTOR AT THE SAME LOCATION. NEW MOTOR IS THE SAME HORSEPOWER AS THE EXISTING.
KEY PLAN
NO SCALE
AREA OF WORK
N
14904.010
2/08/2019
- 2/08/2019
FINAL SUBMISSION
FINAL SUBMISSION
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D
The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE DESCRIPTION
TH
E
JO
H
N F
. K
EN
N
ED
Y C
EN
TE
R fo r t he
P
ER
FO
R
M
IN
G A
R
TS
F .S
T, N
W W
A
SH
IN
G
TO
N
, D C
C O
N D
E N
S E
R
W
A T
S
T E
M
R
E P
A I R
S
J F
K K
T
A S
K
SEAL:
PARTIAL FLOOR PLAN - RIVER PUMP ROOM - ELECTRICAL NEW WORK -
PARKING LEVEL 'C' (8' ELEVATION)
DRAWING SCALE: 1/8" = 1'-0"
E-401
PARTIAL FLOOR PLAN -
RIVER PUMP ROOM -
ELECTRICAL NEW WORK -
PARKING LEVEL 'C'
TJM
FJL
G p r o je c ts .0 c a d d S u b m is si o n
F in a l\ .0
E .d w g
:3 :3
P M
JR
A
IT
H
EX CURB
DRAWING NOTES:
EX SPARE 3 POLE 200 AMP SWITCH FOR COOLING TOWER 1. FUSE AT 200 AMPS.
2 EX SPARE 3 POLE 200 AMP SWITCH FOR COOLING TOWER 2. FUSE AT 200 AMPS.
EX SECTION EX SECTION
EX SW/F
SPACE
METERING
MAIN
INCOMING
SECTION
(APPLY TO THIS DRAWING ONLY)
CT-2
200A
600V
CT-1
200A
600V
PUMP 2
400A
600V
PUMP 1
400A
600V
DISCONNECT WITH AMPACITY AS INDICATED. PROVIDE KINDORF CHANNEL
MOUNTED TO MECHANICAL PIPE SUPPORT AND MOUNT DISCONNECT TO
KINDORF RACK. COORDINATE MOUNTING IN FIELD. SEE ELECTRICAL ONE
LINE ON DRAWING E-502 FOR ADDITIONAL INFORMATION. BASIN HEATERS,
IF ANY, SHALL BE INTERLOCKED WITH MOTORS SUCH THAT EITHER THE
MOTORS RUN OR THE HEATERS RUN. PROVIDE NEMA 3R ENCLOSURE.
5 GALVANIZED KINDORF CHANNEL FOR MOUNTING DISCONNECTS/STARTERS.
3 3 4 4
EX SECTION
EX SW/F
EX SW/F
EX SW/F
EX SW/F
EX SW/F
SPACE
SPACE
SPACE
7'-0"
WIRE TROUGH - SEE ELECTRICAL
ONE LINE FOR ADDITIONAL INFORMATION.
WIRE TROUGH SHALL BE SUITABLE FOR
WET LOCATION.
METERING
MAIN
INCOMING
SECTION
SPACE
SPACE
EX SW/F
EX SW/F
EX SW/F
EX SW/F
EX SW/F
SPACE
SPACE
SPACE
EX SW/F
EX SW/F
EX SW/F
EX SW/F
EX SW/F
EX SW/F
EX SW/F
EX SW/F
SPACE
SPACE
EX SW/F
EX SW/F EX SW/F
EX SW/F EX SW/F
EX SW/F EX SW/F
EX SW/F EX SW/F
EX SW/F
EX SW/F
EX SW/F
EX SW/F
SPACE
EX SPARE 3 POLE 600 AMP SWITCH FOR PUMP 1 AND PUMP 2. FUSE AT 600 AMPS.
SPARE
SPARE
EX SW/F
3 COMBINATION 400 AMP FUSED DISCONNECT AND SOLID STATE STARTER.
FUSE AT 250 AMPS IN NEMA 3R ENCLOSURE. PROVIDE ALL REQUIRED
AUXILIARY CONTACTS, RELAYS, ETC. AS REQUIRED FOR THE MOTOR
SEQUENCE OF CONTROLS. PROVIDE KINDORF CHANNEL MOUNTED TO
MECHANICAL PIPE SUPPORT AND MOUNT TO KINDORF RACK.
COORDINATE MOUNTING IN FIELD. SEE ELECTRICAL ONE LINE ON
DRAWING E-502 FOR ADDITIONAL INFORMATION.
7 PROVIDE 3P-60A, 600V NFSS, IN NEMA 3R ENCLOSURE.
TRANSFORMER
PRIMARY
DISCONNECT
PANELBOARD
LC-17-1A
T
DRY TYPE TRANSFORMER: 15KVA, 480V -
208Y/120V, 3Ø, 4W IN NEMA 3R ENCLOSURE.
GFI
SUITABLE FOR
WET LOCATION.
8 EX SPARE 3 POLE 60 AMP SWITCH FOR TRANSFORMER PRIMARY FEEDER. FUSE AT
35 AMPS.
14904.010
2/08/2019
- 2/08/2019
FINAL SUBMISSION
FINAL SUBMISSION
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D
The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE DESCRIPTION
TH
E
JO
H
N F
. K
EN
N
ED
Y C
EN
TE
R fo r t he
P
ER
FO
R
M
IN
G A
R
TS
F .S
T, N
W W
A
SH
IN
G
TO
N
, D C
C O
N D
E N
S E
R
W
A T
S
T E
M
R
E P
A I R
S
J F
K K
T
A S
K
SEAL:
E-501
ELECTRICAL DETAILS AND
ELEVATIONS
1/2"=1'-0"
0 1' 2' 3' 4' 5' 6'
CAUTION:
IF THIS PLAN IS A REDUCTION, GRAPHIC SCALES
MUST BE USED.
GRAPHIC SCALE
DISCONNECT ELEVATION FOR
TEMPORARY MECHANICAL EQUIPMENT
SCALE:
" = 1'-0"
ELEVATION OF EXISTING
SWITCHBOARD SH-LC-3A
NOT TO SCALE
ELEVATION OF EXISTING
SWITCHBOARD OH-LC-3A2
NOT TO SCALE
TJM
FJL
G p r o je c ts .0 c a d d S u b m is si o n
F in a l\ .0
E .d w g
:3 :3
P M
JR
A
IT
H
DRAWING NOTES:
(APPLY TO THIS DRAWING ONLY)
1 EX 600A SWITCH. PROVIDE 3-600 AMP FUSES.
2 TWO EXISTING 200 AMP SWITCHES. PROVIDE 3-200 AMP FUSES
IN EACH.
3 3P, 200A NFSS WITH SOLID NEUTRAL IN NEMA 3R ENCLOSURE.
LUG WIRE RANGE #6 - 300KCMIL. CIRCUIT SIZED FOR 136 AMPS
THAT INCLUDES FAN MOTORS AND HEATERS THAT DO NOT
OPERATE SIMULTANEOUSLY. CONTRACTOR TO MAKE
TERMINATIONS OF FEEDERS FURNISHED WITH TEMPORARY
EQUIPMENT AND DISCONNECT AND REMOVE WHEN PROJECT
IS COMPLETE.
4 COMBINATION DISCONNECT AND SOLID STATE STARTER.
PROVIDE WITH SOLID STATE STARTER. 3P, 400A FSS IN NEMA 3R
ENCLOSURE AND SOLID NEUTRAL, FUSED AT 250 AMPS. LUGS
SHALL ACCOMMODATE ONE #1/0 - 750KCMIL OR TWO #1/0 -
300KCMIL CABLE. FUSE SIZED FOR MAXIMUM OF 150HP PUMP
MOTOR. CONTRACTOR TO MAKE TERMINATION OF FEEDERS
FURNISHED WITH TEMPORARY EQUIPMENT AND DISCONNECT
AND REMOVE WHEN PROJECT IS COMPLETE. CONTRACTOR
SHALL MAKE CONNECTION DIRECTLY TO PUMP MOTOR.
CONTACTOR FURNISHED WITH THE PUMP SHALL NOT BE
PERMITTED TO BE CONNECTED IN SERIES WITH THE SOFT
START DRIVE. PROVIDE NEMA 3R ENCLOSURE.
5 WIRE TROUGH - SIZE AS REQUIRED. SHALL BE SUITABLE FOR
WET LOCATION.
6 4#3/0 AND 1#6 GROUND IN 2" CONDUIT.
7 3 SETS (4-500KCMIL AND 1#4/0 GROUND WIRE IN 3" CONDUIT).
8 2 SETS (4-500KCMIL AND 1#4/0 GROUND WIRE IN 3" CONDUIT).
TAP ALL PARALLEL CONDUCTORS.
9 4-500KCMIL AND 1#4/0 GROUND WIRE IN 3" CONDUIT. TAP ALL
PARALLEL CONDUCTORS.
1 2
JUNCTION BOX. SIZE AS REQUIRED.
EXISTING SWITCHBOARD
OH-LC-3A2. SEE E-501 FOR
ADDITIONAL INFORMATION.
EXISTING SWITCHBOARD
SH-LC-3A. SEE E-501 FOR
ADDITIONAL INFORMATION.
FOR COOLING
TOWER CT-1
FOR COOLING
TOWER CT-2
FOR RENTAL
PUMP-1
FOR RENTAL
PUMP-2
4 4
10 3#8 & 1#10 GROUND WIRE IN
" CONDUIT.
11 4#4 & 1#8 GROUND WIRE IN 1
" CONDUIT.
PANELBOARD
LC-17-1A
DRY TYPE TRANSFORMER: 15KVA, 480 - 208Y/120 VOLTS,
3 PHASE, IN NEMA 3R ENCLOSURE.
3P, 60A NFSS IN NEMA 3R ENCLOSURE.
T
1#8 GROUNDING ELECTRODE CONDUCTOR IN
" CONDUIT.
MAKE CONNECTION TO BUILDING GROUNDING ELECTRODE
SYSTEM.
15 3#10 & 1#10 GROUND WIRE IN
" CONDUIT.
EXISTING 3P-60A SWITCH. PROVIDE 3-35 AMP FUSES. MATCH
EXISTING FUSE TYPES.
14904.010
2/08/2019
- 2/08/2019
FINAL SUBMISSION
FINAL SUBMISSION
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D
The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE DESCRIPTION
TH
E
JO
H
N F
. K
EN
N
ED
Y C
EN
TE
R fo r t he
P
ER
FO
R
M
IN
G A
R
TS
F .S
T, N
W W
A
SH
IN
G
TO
N
, D C
C O
N D
E N
S E
R
W
A T
S
T E
M
R
E P
A I R
S
J F
K K
T
A S
K
SEAL:
ELECTRICAL ONE-LINE DIAGRAM
NOT TO SCALE
E-502
ELECTRICAL ONE-LINE
DIAGRAM
TJM
FJL
G p r o je c ts .0 c a d d S u b m is si o n
F in a l\ .0
E .d w g
:3 :4
P M
JR
A
IT
H