3195 Drawings.pdf
PDF 11 MB Posted
- Solicitation number
- 3195
- Issued by
- Hinds County, Weir Town, Mississippi
About this file
These architectural and engineering drawings detail the structural repairs and additions project for the Sheffield-Woolley Residence Hall at Hinds Community College's Raymond Campus in Mississippi. The project scope includes the demolition of the existing south exterior fire stair tower and construction of a new replacement fire egress stair that meets local, state, and federal building codes. Additionally, the project involves upgrading the existing elevator at the lobby, with work to be completed after the south stair work is finished and ready for use by the owner and dormitory occupants.
The project, identified as HCC Project No. 3195, is being managed by Brumfield Ward & Associates Architects, with civil/structural engineering by PTAC Consulting Engineers and mechanical/electrical engineering by Edmonds Engineering. The drawings provide comprehensive details on demolition plans, stair sections, foundation plans, electrical and mechanical layouts, and fire protection specifications. The building will remain occupied throughout the construction period, requiring close coordination with the college. The project documents indicate a preliminary design phase as of March 31, 2020, with detailed plans for phased renovation of the south and potentially north stair areas across multiple floors of the residence hall.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 3195 Project Manual.pdf | ||
| 3195 Adendum1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT SCOPE OVERVIEW:
THE SCOPE OF WORK INCLUDES THE DEMOLITION OF THE EXISTING SOUTH EXTERIOR FIRE STAIR
TOWER. A NEW REPLACEMENT FIRE EGRESS STAIR WILL BE CONSTRUCTED. THE STAIR
WILL MEET AND/OR EXCEED LOCAL, STATE, AND FEDERAL CODES.
AS PART OF THIS PROJECT IS THE UPGRADING OF THE EXISTING ELEVATOR AT THE LOBBY. THIS WORK WILL TAKE PLACE AFTER THE SOUTH STAIR WORK IS COMPLETE AND READY FOR USE BY THE
OWNER AND THE DORM OCCUPANTS.
THIS PROJECT DOES NOT REQUIRE A CODE EVALUATION. THE WORK INCLUDES THE DEMOLITION
OF THE EXISTING SOUTH EXTERIOR FIRE STAIR THAT IS STRUCTURALLY FAILING AND THE
ADDITION OF A NEW STAIR. THIS WORK WILL NOT MODIFY THE CODE COMPLIANCE OF THE
BUILDING.
COMMENT: THE ABOVE IS NOT INTENDED TO CONSTITUTE A COMPREHENSIVE CODE EVALUATION
OF THE ENTIRE FACILITY; RATHER IT IS TO ADDRESS THE MODIFICATIONS OF THE RENOVATED
AREAS AND ANY ASSOCIATED CODE REQUIREMENT PERTAINING THERETO.
NOTE: THE BUILDING WILL BE OCCUPIED FOR THE DURATION OF THE WORK AND CLOSE
COORDINATION WITH THE COLLEGE WILL BE MAINTAINED.
SHEET:
Brumfield
JOB NUMBER
SSOCIATES
RCHITECTs
DRAWN BY:
CHECKED BY:
DATE:
R E
V
IS
IO
N
S O
W N
E R
Ward
TS/EK
RW
3/31/2020
18-040
__ of __ SHEETS
SHEET:
Brumfield
JOB NUMBER
SSOCIATES
RCHITECTs
DRAWN BY:
CHECKED BY:
DATE:
O W
N E
R
Ward
DRAWING
SHEET:
Brumfield
JOB NUMBER
SSOCIATES
RCHITECTs
DRAWN BY:
CHECKED BY:
DATE:
R E
V
IS
IO
N
S O
W N
E R
Ward
TS/EK
RW
3/31/2020
18-040
__ of __ SHEETS
SHEET:
Brumfield
JOB NUMBER
SSOCIATES
RCHITECTs
DRAWN BY:
CHECKED BY:
DATE:
O W
N E
SHEET:
Brumfield
JOB NUMBER
SSOCIATES
RCHITECTs
DRAWN BY:
CHECKED BY:
DATE:
R E
V
IS
IO
N
S O
W N
E R
Ward
TS/EK
RW
3/31/2020
18-040
__ of __ SHEETS
SHEET:
Brumfield
JOB NUMBER
SSOCIATES
RCHITECTs
DRAWN BY:
CHECKED BY:
DATE:
O W
N E
CO
Charles K. Hines, PLS
MS Certification No. 3187
WG
K
Horizontal and Vertical orientation derived from GPS observations and NAD83(2011)
GRID data, Mississippi State Plane West Zone, and NAVD88 datum, having a combined factor of 0.99995071 and a convergence angle of -0°02'34.8099", as sampled at WGK control point #1, as shown hereon.
Subject property is located within an area having Zone Designations 'X' by the
Secretary of Housing and Urban Development, as approximately scaled from Flood
Insurance Rate Map No. 28049C0270H, with a date of identification of November 18, 2009, in the Town of Raymond, Hinds County, State of Mississippi, which is the current
Flood Insurance Rate map for the community in which said premises is situated.
Zone 'X' - Areas determined to be outside of the 0.2% annual chance flood plain.
Location of underground utilities shown on plat is approximate only, and is based on surface evidence of same, or information provided by others. Other underground utilities/structures may exist that were not evident to surveyor.
Subsurface and environmental conditions were not examined or considered as a part of this survey.
This property may be subject to recorded or unrecorded easements, rights-of-way or other encumbrances which are not evident to the surveyor, but which would be revealed by a title search performed by an attorney.
This survey was performed and this plat was prepared by WGK, Inc., Engineers &
Surveyors, P.O. Box 318, Clinton, Mississippi 39060. Phone: (601) 925-4444
This survey is considered valid only when original seal and signature of surveyor of record is affixed hereto.
I, Charles K. Hines, do hereby certify, to the best of my knowledge, belief, and information, that the features depicted on this plat are a representation of the conditions as they existed on July 25, 2018.
RAYMOND, HINDS COUNTY, MS
HINDS COMMUNITY COLLEGE
E N
G
IN
E E
R S
S
U R
V E
Y O
R S
G K W
P.
O
. B O
X
, R
AY
M
O N
D, M
S
HI
N
DS
C
O M
M U
N
IT
Y
CO
LL
EG
E
- R
AY
M
O N
D
SH
EF
FI
EL
D
- W O
O
LL
EY
R
ES
ID
EN
CE
H
AL
L
G
UT
CO
W
__ of __ SHEETS
SHEET:
Brumfield
SSOCIATES
RCHITECTs
DRAWN BY:
CHECKED BY:
DATE:
Ward
TS/EK
RW
02/22/2019
__ of __ SHEETS
SHEET:
Brumfield
JOB NUMBER
SSOCIATES
RCHITECTs
DRAWN BY:
CHECKED BY:
DATE:
WG
K
RAYMOND, HINDS COUNTY, MS
HINDS COMMUNITY COLLEGE
G
UT
CO
W
SHEET:
Brumfield
JOB NUMBER
SSOCIATES
RCHITECTs
DRAWN BY:
CHECKED BY:
DATE:
R E
V
IS
IO
N
S O
W N
E R
Ward
TS/EK
RW
3/31/2020
18-040
__ of __ SHEETS
SHEET:
Brumfield
JOB NUMBER
SSOCIATES
RCHITECTs
DRAWN BY:
CHECKED BY:
DATE:
O W
N E
1 @ FIRST FLOOR
SOUTH STAIR
1/4"=1-0"
2 @ SECOND FLOOR
SOUTH STAIR
1/4"=1-0" 3 @ THIRD FLOOR
SOUTH STAIR
1/4"=1-0"
4 @ FOURTH FLOOR
SOUTH STAIR
1/4"=1-0" 5 @ ROOF ACCESS
SOUTH STAIR
1/4"=1-0"
LEGEND
SHEET:
Brumfield
JOB NUMBER
SSOCIATES
RCHITECTs
DRAWN BY:
CHECKED BY:
DATE:
R E
V
IS
IO
N
S O
W N
E R
Ward
TS/EK
RW
3/31/2020
18-040
__ of __ SHEETS
SHEET:
Brumfield
JOB NUMBER
SSOCIATES
RCHITECTs
DRAWN BY:
CHECKED BY:
DATE:
O W
N E
R
Ward
KEY PLAN
NTS
REF. PHOTO "A" REF. PHOTO "B"
DEMO PLANS
REMOVE LANDSCAPING
W
G
U
T
U
T
G
6"
NEW FIRE
HYDRANT
CONNECT
TO EXISTING
6"
NEW FIRE
HYDRANT
CONNECT
TO EXISTING
AWWA GATE VALVE
IN CAST IRON BOX
AWWA GATE VALVE
IN CAST IRON BOX
EXISTING
FIRE MAIN
EXISTING BFP
EXISTING
WATER MAIN
EXISTING BUILDING
THRUST BLOCK
THRUST BLOCK
THRUST BLOCK
PHASE I
PHASE II
MS1.1
REPRODUCTION OR COPY
OF THIS DRAWING IN
WHOLE OR PART SHALL
NOT BE USED ON ANY
OTHER PROJECT AND IS
TO BE RETURNED UPON
R E Q U E S T . A L L I N F O R M A T I O N
CONTAI NED I N THI S
D R A W I N G I S
COPYRIGHTED AS OF THE
D A T E N O T E D .
PROFESSIONAL STAMP
SHEET:
Brumfield
HAROLD C. BRUMFIELD, JR.
CSI, CCCA, AIA, NCARB No. 25189
W. RANDY WARD
AIA, LEED AP, MS. Lic. No. 2539
1030 North Park Drive, Ste A Ridgeland, Mississippi 39157
JOB NUMBER
B A&W aSSOCIATES aRCHITECTs
Tel #: (601) 982-0341 Fax #: (601) 899-4799
DRAWN BY:
CHECKED BY:
DATE:
R E
V
IS
IO
N
S O
W N
E R
Ward
S H
EF
FI
EL
D
-W O
O
LL
EY
(R
AY
M
ON
D
CA
M
PU
S) R
A Y
M O
N D
, M
IS
SI
SS
IP
PI
(H C
C P
R O
JE
C
T #3
7)
ST
R
U C
TU
R
A L
R
EP
A
IR
S/ A
D D
IT
IO
N S
H
IN
D S
C O
M M
U N
IT
Y
C O
LL
EG
E (C
O M
M U
N
IT
Y C
O
LL
EG
E
B O
A R
D
PRELIMINARY
HCC PROJECT #3157
RAYMOND, MISSISSIPPI
HINDS COMMUNITY COL.
STRUC. REPAIRS/ADDITIONS
2018 SHEFFIELD-WOOLLEY
18-040
12/11/2019
1900 Lakeland Drive
Jackson, MS 39216
(601) 362-6478
Project Number :
EDMONDS
Trusted Engineering Solutions www.edmondsengineering.com
JAN18057
TEG
DLG
E
GIER
A
AT
ST
D
NO
N
I S
N G NI E E
OF MISS
No. 13816
E R
SIP
PI
LA
S OI
GLD
D
TS
ERE
L
OPR EF S
NE
ER
N SCALE: 1" = 20'-0"
SITE PLAN - MECHANICAL
32 44
AutoCAD SHX Text
SHEFFIELD-WOOLLEY RESIDENCE HALL
AutoCAD SHX Text FINISH FLOOR ELEVATIONS (OBSERVED AT STAIRWELLS) 1st FLOOR: 283.80 2nd FLOOR: 293.00 3rd FLOOR: 301.40 4th FLOOR: 310.00
AutoCAD SHX Text
SHEFFIELD-WOOLLEY RESIDENCE HALL
AutoCAD SHX Text FINISH FLOOR ELEVATIONS (OBSERVED AT STAIRWELLS) 1st FLOOR: 283.80 2nd FLOOR: 293.00 3rd FLOOR: 301.40 4th FLOOR: 310.00
AutoCAD SHX Text
CONCRETE A/C PAD
AutoCAD SHX Text
CONCRETE A/C PAD
AutoCAD SHX Text
CONC.
AutoCAD SHX Text
CONC.
AutoCAD SHX Text
FFE: 281.22
AutoCAD SHX Text
FFE: 280.25
AutoCAD SHX Text
CONCRETE A/C PAD
AutoCAD SHX Text
CONCRETE WALK
AutoCAD SHX Text
CONCRETE WALK
AutoCAD SHX Text
CONCRETE WALK
AutoCAD SHX Text
CONCRETE WALK
AutoCAD SHX Text
ASPHALT PARKING
AutoCAD SHX Text
ASPHALT PARKING
AutoCAD SHX Text
CONCRETE WALK
AutoCAD SHX Text
CONCRETE WALK
AutoCAD SHX Text
INLET TOP: 279.80 INV IN SW(8"PVC): 278.21 INV OUT SE(18"RCP): 277.84
AutoCAD SHX Text WGK CONTROL #2 STATE PLANE N: 1002407.03 E: 2271418.40 ELEV: 281.86 60d NAIL
AutoCAD SHX Text WGK CONTROL #1 STATE PLANE N: 1002183.44 E: 2271674.28 ELEV: 279.95 60d NAIL
AutoCAD SHX Text
GREAVES RESIDENCE HALL
AutoCAD SHX Text
OPEN GRASS
AutoCAD SHX Text
OPEN GRASS
AutoCAD SHX Text
OPEN GRASS
AutoCAD SHX Text
OPEN GRASS
AutoCAD SHX Text
OPEN GRASS
AutoCAD SHX Text
OPEN GRASS
AutoCAD SHX Text
OPEN GRASS
AutoCAD SHX Text
CURB/GUTTER
AutoCAD SHX Text
CURB/GUTTER
AutoCAD SHX Text
15" CYPRESS
AutoCAD SHX Text
10" BIRCH
AutoCAD SHX Text
26" PECAN
AutoCAD SHX Text
20" BIRCH
AutoCAD SHX Text
20" BIRCH
AutoCAD SHX Text
CONCRETE BASE FOR LIGHT POLE
AutoCAD SHX Text
SIAMESE WATER CONNECTION
AutoCAD SHX Text
SIAMESE WATER CONNECTION
AutoCAD SHX Text
2" CONDENSATE DRAIN
AutoCAD SHX Text
30" PECAN
AutoCAD SHX Text
25" ASH
AutoCAD SHX Text 01 / 21 / 2O20
SCALE: 1/4" = 1'-0"
DEMO - FIRE PROTECTION - PHASE I
SOUTH STAIR PLAN AT FIRST FLOOR -
EXISTING
F.D.C.
TEMP PARTITION.
SEE D1.1
SCALE: 1/4" = 1'-0"
DEMO - FIRE PROTECTION - PHASE I
SOUTH STAIR PLAN AT SECOND FLOOR -
TEMP PARTITION.
SEE D1.1
SCALE: 1/4" = 1'-0"
DEMO - FIRE PROTECTION - PHASE I
SOUTH STAIR PLAN AT THIRD FLOOR -
TEMP PARTITION.
SEE D1.1
SCALE: 1/4" = 1'-0"
DEMO - FIRE PROTECTION - PHASE I
SOUTH STAIR PLAN AT FOURTH FLOOR -
TEMP PARTITION.
SEE D1.1
SCALE: 1/4" = 1'-0"
DEMO - FIRE PROTECTION - PHASE I
SOUTH STAIR PLAN AT ROOF ACCESS -
KEY PLAN
NTS
MD1.1
DEMO PLANS
BASE BID
REPRODUCTION OR COPY
OF THIS DRAWING IN
WHOLE OR PART SHALL
NOT BE USED ON ANY
OTHER PROJECT AND IS
TO BE RETURNED UPON
R E Q U E S T . A L L I N F O R M A T I O N
CONTAI NED I N THI S
D R A W I N G I S
COPYRIGHTED AS OF THE
D A T E N O T E D .
PROFESSIONAL STAMP
SHEET:
Brumfield
HAROLD C. BRUMFIELD, JR.
CSI, CCCA, AIA, NCARB No. 25189
W. RANDY WARD
AIA, LEED AP, MS. Lic. No. 2539
1030 North Park Drive, Ste A Ridgeland, Mississippi 39157
JOB NUMBER
B A&W aSSOCIATES aRCHITECTs
Tel #: (601) 982-0341 Fax #: (601) 899-4799
DRAWN BY:
CHECKED BY:
DATE:
R E
V
IS
IO
N
S O
W N
E R
Ward
S H
EF
FI
EL
D
-W O
O
LL
EY
(R
AY
M
ON
D
CA
M
PU
S) R
A Y
M O
N D
, M
IS
SI
SS
IP
PI
(H C
C P
R O
JE
C
T #3
7)
ST
R
U C
TU
R
A L
R
EP
A
IR
S/ A
D D
IT
IO
N S
H
IN
D S
C O
M M
U N
IT
Y
C O
LL
EG
E (C
O M
M U
N
IT
Y C
O
LL
EG
E
B O
A R
D
PRELIMINARY
HCC PROJECT #3157
RAYMOND, MISSISSIPPI
HINDS COMMUNITY COL.
STRUC. REPAIRS/ADDITIONS
2018 SHEFFIELD-WOOLLEY
18-040
12/11/2019
1900 Lakeland Drive
Jackson, MS 39216
(601) 362-6478
Project Number :
EDMONDS
Trusted Engineering Solutions www.edmondsengineering.com
JAN18057
TEG
DLG
E
GIER
A
AT
ST
D
NO
N
I S
N G NI E E
OF MISS
No. 13816
E R
SIP
PI
LA
S OI
GLD
D
TS
ERE
L
OPR EF S
NE
ER
NOTES:
REMOVE EXISTING FIRE PROTECTION STANDPIPE AND RELATED HANGERS/SUPPORTS.1
AutoCAD SHX Text M
AutoCAD SHX Text N
AutoCAD SHX Text Q
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text M
AutoCAD SHX Text N
AutoCAD SHX Text Q
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text M
AutoCAD SHX Text N
AutoCAD SHX Text Q
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text M
AutoCAD SHX Text N
AutoCAD SHX Text Q
AutoCAD SHX Text M
AutoCAD SHX Text N
AutoCAD SHX Text Q
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SOUTH STAIR LOCATION
4"
THRUST BLOCK
NEW 4" STAND PIPE
F 4"
SCALE: 1/4" = 1'-0"
AT FIRST FLOOR - MECHANICAL - PHASE I
SOUTH STAIR PLAN
NEW REMOTE
F.D.C.
NEW 4" STAND PIPE
SCALE: 1/4" = 1'-0"
AT SECOND FLOOR - MECHANICAL - PHASE I
SOUTH STAIR PLAN
NEW 4" STAND PIPE
SCALE: 1/4" = 1'-0"
AT THIRD FLOOR - MECHANICAL - PHASE I
SOUTH STAIR PLAN
NEW 4" STAND PIPE
SCALE: 1/4" = 1'-0"
AT FOURTH FLOOR - MECHANICAL - PHASE I
SOUTH STAIR PLAN
SCALE: 1/4" = 1'-0"
AT MAIN ROOF - MECHANICAL - PHASE I
NEW 4" STAND PIPE
SOUTH STAIR PLAN
KEY PLAN
NTS
M1.1
BASE BID
REPRODUCTION OR COPY
OF THIS DRAWING IN
WHOLE OR PART SHALL
NOT BE USED ON ANY
OTHER PROJECT AND IS
TO BE RETURNED UPON
R E Q U E S T . A L L I N F O R M A T I O N
CONTAI NED I N THI S
D R A W I N G I S
COPYRIGHTED AS OF THE
D A T E N O T E D .
PROFESSIONAL STAMP
SHEET:
Brumfield
HAROLD C. BRUMFIELD, JR.
CSI, CCCA, AIA, NCARB No. 25189
W. RANDY WARD
AIA, LEED AP, MS. Lic. No. 2539
1030 North Park Drive, Ste A Ridgeland, Mississippi 39157
JOB NUMBER
B A&W aSSOCIATES aRCHITECTs
Tel #: (601) 982-0341 Fax #: (601) 899-4799
DRAWN BY:
CHECKED BY:
DATE:
R E
V
IS
IO
N
S O
W N
E R
Ward
S H
EF
FI
EL
D
-W O
O
LL
EY
(R
AY
M
ON
D
CA
M
PU
S) R
A Y
M O
N D
, M
IS
SI
SS
IP
PI
(H C
C P
R O
JE
C
T #3
7)
ST
R
U C
TU
R
A L
R
EP
A
IR
S/ A
D D
IT
IO
N S
H
IN
D S
C O
M M
U N
IT
Y
C O
LL
EG
E (C
O M
M U
N
IT
Y C
O
LL
EG
E
B O
A R
D
PRELIMINARY
HCC PROJECT #3157
RAYMOND, MISSISSIPPI
HINDS COMMUNITY COL.
STRUC. REPAIRS/ADDITIONS
2018 SHEFFIELD-WOOLLEY
18-040
12/11/2019
1900 Lakeland Drive
Jackson, MS 39216
(601) 362-6478
Project Number :
EDMONDS
Trusted Engineering Solutions www.edmondsengineering.com
JAN18057
TEG
DLG
E
GIER
A
AT
ST
D
NO
N
I S
N G NI E E
OF MISS
No. 13816
E R
SIP
PI
LA
S OI
GLD
D
TS
ERE
L
OPR EF S
NE
ER
AutoCAD SHX Text
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
SOUTH STAIR LOCATION
M1.3
BASE BID
REPRODUCTION OR COPY
OF THIS DRAWING IN
WHOLE OR PART SHALL
NOT BE USED ON ANY
OTHER PROJECT AND IS
TO BE RETURNED UPON
R E Q U E S T . A L L I N F O R M A T I O N
CONTAI NED I N THI S
D R A W I N G I S
COPYRIGHTED AS OF THE
D A T E N O T E D .
PROFESSIONAL STAMP
SHEET
Brumfield
HAROLD C. BRUMFIELD, JR.
CSI, CCCA, AIA, NCARB No. 25189
W. RANDY WARD
AIA, LEED AP, MS. Lic. No. 2539
1030 North Park Drive, Ste A Ridgeland, Mississippi 39157
JOB NUMBER
B A&W aSSOCIATES aRCHITECTs
Tel #: (601) 982-0341 Fax #: (601) 899-4799
DRAWN BY:
CHECKED BY:
DATE:
R E
V
IS
IO
N
S O
W N
E R
Ward
S H
EF
FI
EL
D
-W O
O
LL
EY
(R
AY
M
ON
D
CA
M
PU
S) R
A Y
M O
N D
, M
IS
SI
SS
IP
PI
(H C
C P
R O
JE
C
T #3
7)
ST
R
U C
TU
R
A L
R
EP
A
IR
S/ A
D D
IT
IO
N S
H
IN
D S
C O
M M
U N
IT
Y
C O
LL
EG
E (C
O M
M U
N
IT
Y C
O
LL
EG
E
B O
A R
D
PRELIMINARY
HCC PROJECT #3157
RAYMOND, MISSISSIPPI
HINDS COMMUNITY COL.
STRUC. REPAIRS/ADDITIONS
2018 SHEFFIELD-WOOLLEY
18-040
12/11/2019
1900 Lakeland Drive
Jackson, MS 39216
(601) 362-6478
Project Number :
EDMONDS
Trusted Engineering Solutions www.edmondsengineering.com
JAN18057
TEG
DLG
E
GIER
A
AT
ST
D
NO
N
I S
N G NI E E
OF MISS
No. 13816
E R
SIP
PI
LA
S OI
GLD
D
TS
ERE
L
OPR EF S
NE
ER
NO SCALE
FREE STANDING FIRE DEPARTMENT
6"
FROM BUILDING
6"
FINISH GRADE
FREE STANDING SIEMESE FIRE DEPT. CONNECTIONS
(2) EQUAL TO POTTER ROEMER SERIES 5763-D 6"x 21
2".
12" x 12" x 4" CONCRETE PAD
AROUND FIRE DEPT. CONN. POST.
TWO-WAY BRASS
BODY W/ CLAPPERS
CONNECTION DETAIL
MIN.
MIN. FR. CURB
MIN. FR. ROAD EDGE
NO SCALE
FIRE HYDRANT DETAIL
SECTION VIEW
PLAN VIEW
DRAIN OPEN
LEAVE HYDRANT
BACK-FILL
CONN. FACING ROAD
4 1/2" PUMPER
OUTLETS.
(2) 2 1/2" HOSE
" M
IN
4"
" M
IN
IM
UM
FINISH GRADE
FOR EACH HYDRANT CONN.
W/ C.I. ROADWAY VALVE BOX
PROVIDE 6" GATE VALVE
IN PLACE.
BLOCKING CAST
CONCRETE
THROUGHLY.
DRAIN POCKET. COMPACT
GRAVEL OR CRUSHED ROCK
"1
6"
18"18"
FIRE HYDRANT EQUAL TO MUELLER COMPANY
CENTURION, 3-WAY, TWO 2½" AND ONE 5¼"
NATIONAL STANDARD THREAD HOSE AND
PUMPER CONNECTION. 30" BURY.
IN COVER.
W/ LETTER "W" CAST
PROVIDE METAL COVER
GATE VALVE
VALVE BOX
CONCRETE SLAB
FIN. GRADE
SLOPE 1/2" SLOPE 1/2"
6"6"
6"
LIGHTING FIXTURE SCHEDULE
S H
EF
FI
EL
D
-W O
O
LL
EY
(R
AY
M
ON
D
CA
M
PU
S) R
A Y
M O
N D
, M
IS
SI
SS
IP
PI
(H C
C P
R O
JE
C
T #3
7)
ST
R
U C
TU
R
A L
R
EP
A
IR
S/ A
D D
IT
IO
N S
H
IN
D S
C O
M M
U N
IT
Y
C O
LL
EG
E (C
O M
M U
N
IT
Y C
O
LL
EG
E
B O
A R
D
1900 Lakeland Drive
Jackson, MS 39216
(601) 362-6478
Project Number :
EDMONDS
Trusted Engineering Solutions www.edmondsengineering.com
JAN18057
20238
S
H
A
N
E
AR
M
O
U
R
P
RO
F
E
S
S
I
O
N A
L
L
I C
E
N
S
E
D
ENGINEER
STATE OF MISS ISSIPP
I
E0.1
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
1. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE
AutoCAD SHX Text AND LOCAL ORDINANCES AS ENFORCED BY THE AUTHORITY HAVING JURISDICTION. CONTRACTOR
AutoCAD SHX Text
2. CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH ALL DETAILS OF THE
AutoCAD SHX Text
WORK AND ALL EXISTING FIELD CONDITIONS.
AutoCAD SHX Text
4. THE ELECTRICAL CONTRACTOR SHALL CAREFULLY COORDINATE HIS WORK WITH OTHER
AutoCAD SHX Text
CONTRACTORS THROUGH THE GENERAL CONTRACTOR FOR SPACE REQUIREMENTS, ETC.
AutoCAD SHX Text
5. CONTRACTOR SHALL VERIFY ALL MECHANICAL EQUIPMENT NAMEPLATE DATA BEFORE ANY WORK IS
AutoCAD SHX Text
DONE AND MAKE ANY ADJUSTMENTS IN BREAKER AND WIRE SIZE AS MAY BE REQUIRED.
AutoCAD SHX Text
6. SHOULD THE CONTRACTOR FIND DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS OR
AutoCAD SHX Text
BE IN DOUBT AS TO INTENT, HE SHALL IMMEDIATELY OBTAIN CLARIFICATION FROM THE
AutoCAD SHX Text
ARCHITECT OR ENGINEER.
AutoCAD SHX Text
7. THE ELECTRICAL DRAWINGS ARE SCHEMATIC AND ARE NOT INTENDED TO SHOW THE EXACT
AutoCAD SHX Text LOCATION OF CONDUITS, OUTLETS, ETC.. THE CONTRACTOR SHALL REFER TO ARCHITECTURAL, AutoCAD SHX Text
MECHANICAL, AND PLUMBING DRAWINGS AND SHALL FIT HIS WORK TO CONFORM WITH THE
AutoCAD SHX Text
BUILDING CONSTRUCTION, AND WITH THE OTHER TRADES.
AutoCAD SHX Text
8. MOUNTING HEIGHTS OF ALL WALL OUTLETS SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED"
AutoCAD SHX Text
WALL SWITCHES: 44"H.
AutoCAD SHX Text
RECEPTACLES GENERAL: 18"H.
AutoCAD SHX Text
TELEPHONE/DATA: 18"H.
AutoCAD SHX Text
JUNCTION BOX: 18"H.
AutoCAD SHX Text
EXIT LIGHT: CENTERLINE ABOVE DOOR.
AutoCAD SHX Text
9. ELECTRICAL CONTRACTOR SHALL VERIFY EXACT HEIGHT OF ALL COUNTER TOPS AND
AutoCAD SHX Text
BACKSPLASHES ON CASEWORK SHOP DRAWINGS, AND CHANGE SPECIFIED MOUNTING HEIGHT OF
AutoCAD SHX Text WALL OUTLETS INDICATED AS REQUIRED SO THAT BOTTOM OF OUTLET BOX IS 2" ABOVE TOP OF
AutoCAD SHX Text
BACKSPLASH OR IS NO BACKSPLASH IS USED, 4" ABOVE COUNTERTOP.
AutoCAD SHX Text
10. DO NOT MOUNT OUTLETS BACK-TO-BACK. PROVIDE MINIMUM 24" SEPARATION IN FIRE RATED
AutoCAD SHX Text
WALLS.
AutoCAD SHX Text
11. ALL OUTLETS IN EXPOSED CONCRETE BLOCK WALLS SHALL BE ADJUSTED AS REQUIRED TO ALLOW
AutoCAD SHX Text
CUTTING OF ONLY ONE BLOCK. MAINTAIN UNIFORM HEIGHTS THROUGHOUT THE BUILDING.
AutoCAD SHX Text
12. VERIFY ALL DOOR SWINGS WITH ARCHITECT BEFORE ROUGHING LIGHT SWITCHES.
AutoCAD SHX Text
13. CONTRACTOR SHALL CHECK ALL LIGHT FIXTURES FOR EXACT TYPE MOUNTING AND SPACE
AutoCAD SHX Text
REQUIRED BEFORE ROUGHING IN.
AutoCAD SHX Text
14. BRANCH CIRCUITS #12 A.W.G. AND 3/4" CONDUIT (EMT) MINIMUM. CONDUCTORS SHALL
AutoCAD SHX Text BE 98%%% CONDUCTIVITY COPPER, THHN TYPE INSULATION. SERVICE AND FEEDER CONDUCTORS
AutoCAD SHX Text
SHALL HAVE TYPE RHH INSULATION.
AutoCAD SHX Text
15. VOLTAGE DROP: FOR 20 AMP CIRCUITS OVER 100FT. AND LESS THAN 175FT, USE #10
AutoCAD SHX Text
CONDUCTORS. FOR 20 AMP CIRCUITS OVER 174 FEET AND LESS THAN 275 FEET, USE #8
AutoCAD SHX Text
CONDUCTORS.
AutoCAD SHX Text
16. ALL CONDUITS CROSSING EXPANSION JOINTS SHALL HAVE EXPANSION TYPE FITTINGS.
AutoCAD SHX Text
17. ALL CONDUIT INDOORS SHALL BE METALLIC, EMT WHERE EXPOSED. CONDUIT EXPOSED OUTDOORS
AutoCAD SHX Text SHALL BE IMC OR RIGID. CONDUIT UNDERGROUND SHALL BE RIGID OR PVC. PVC SHALL NOT BE
AutoCAD SHX Text
EXPOSED ABOVE GRADE OR FINISH FLOOR LEVEL.
AutoCAD SHX Text
18. ALL RIGID AND IMC CONDUIT SHALL BE HOT DIP GALVANIZED, INSIDE AND OUT, EMT CONDUIT
AutoCAD SHX Text
SHALL BE ELECTRO GALVANIZED, CONDUIT SHALL BE AS MANUFACTURED BY REPUBLIC,
AutoCAD SHX Text
WHEATLAND, ALLIED OR APPROVED EQUAL.
AutoCAD SHX Text
19. ALL CIRCUIT BREAKERS SHALL BE FULLY COMPATIBLE WITH AND MATCH THE AIC RATING OF
AutoCAD SHX Text
THE PANEL IN WHICH THEY ARE INSTALLED.
AutoCAD SHX Text
20. ALL JUNCTION BOXES SHALL BE SUPPORTED INDEPENDENT OF CONDUIT FROM STRUCTURE ABOVE.
AutoCAD SHX Text
21. SUPPORT OF RACEWAYS SHALL BE BY FACTORY MADE SUPPORTS OR HANGERS. SUPPORTS SHALL BE
AutoCAD SHX Text
MADE WITH COLD-FORMED STEEL WITH CORROSION-RESISTANT COATING.
AutoCAD SHX Text
22. TERMINATE ALL DEVICES SUCH THAT REMOVAL OF ONE DEVICE SHALL NOT INTERRUPT POWER
AutoCAD SHX Text
TO DOWNSTREAM DEVICES. PROVIDE AT LEAST 6" SLACK CONDUCTOR AT EACH OUTLET.
AutoCAD SHX Text
23. BRANCH CIRCUIT SPLICES SHALL BE MADE WITH THREADED WIRE-NUT CONNECTORS.
AutoCAD SHX Text
24. CONCEAL ALL CABLES, FEEDERS, AND BRANCH CIRCUITS WHERE CEILING IS PRESENT.
AutoCAD SHX Text
25. SUPPORT LIGHT FIXTURES AT ALL FOUR CORNERS AND INDEPENDENT OF CEILING GRID.
AutoCAD SHX Text
26. FUSES SHALL BE TIME-DELAY, DUAL ELEMENT, UL LISTED WITH A MINIMUM INTERRUPTING
AutoCAD SHX Text
RATING OF 100,000 AMPERES SYMMETRICAL. FUSES SHALL BE BUSSMAN, LITTLEFUSE, OR
AutoCAD SHX Text
APPROVED EQUAL.
AutoCAD SHX Text
27. CONTRACTOR SHALL PROVIDE ARC-FLASH WARNING LABELS COMPLYING WITH NEC ARTICLE 110.16 ON NEW
AutoCAD SHX Text
ELECTRICAL EQUIPMENT OR EXISTING EQUIPMENT THAT IS MODIFIED.
AutoCAD SHX Text
28. NEW PANELBOARDS AND EXISTING PANELBOARDS THAT ARE MODIFIED SHALL BE IDENTIFIED TO INDICATE
AutoCAD SHX Text
THE DEVICE OR EQUIPMENT WHERE THE POWER SUPPLY ORIGINATES.
AutoCAD SHX Text
29. ALL CONDUCTORS SHALL BE CU UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS.
AutoCAD SHX Text
3. ALL NEW CIRCUIT BREAKERS INSTALLED IN EXISTING PANELS SHALL BE FULLY COMPATIBLE WITH
AutoCAD SHX Text
AND MATCH THE AIC RATING OF THE PANEL IN WHICH THEY ARE INSTALLED.
AutoCAD SHX Text
30. ALL NEW ELECTRICAL TERMINATIONS AND DEVICES SHALL BE RATED FOR 75%%DC.
AutoCAD SHX Text
31. FIRE ALARM SYSTEM SHALL BE FULLY ADDRESSABLE CLASS B. PROVIDE ALL DEVICES NECESSARY
AutoCAD SHX Text
FOR A FULLY FUNCTIONAL AND CODE-COMPLIANT INSTALLATION.
AutoCAD SHX Text INDUSTRIAL STRIP, WITH FIXTURE SYMBOL AND CIRCUIT NUMBER. SEE LIGHTING FIXTURE SCHEDULE FOR DESCRIPTION.
AutoCAD SHX Text SOLID CIRCLE ON ANY LIGHT FIXTURE SYMBOL INDICATES FIXTURE EQUIPPED WITH EMERGENCY BATTERY PACK.
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL SYMBOLS LEGEND
AutoCAD SHX Text HOMERUN (CONDUIT AND WIRING) CONCEALED ABOVE CEILING OR IN WALL, WITH NUMBER OF CONDUCTORS INDICATED. ( V ) INDICATES GREEN GROUNDING CONDUCTOR, SMALL ( ) INDICATES PHASE CONDUCTOR(S), OR SWITCHLEGS. LARGER ( ) INDICATES NEUTRAL CONDUCTOR(S). HOMERUN CONDUCTORS SHALL BE MINIMUM #12 AWG UNLESS NOTED OTHERWISE ON THE PLANS OR IN THE SPECIFICATIONS. MINIMUM SIZE FOR CONDUIT IS 3/4", UNLESS NOTED OTHERWISE ON THE PLANS OR IN THE SPECIFICATIONS. INDICATED HOMERUN CONDUCTOR SIZE IS BASED ON ESTIMATED DISTANCES TO PANELS FOR LOADS SERVED FOR A MAXIMUM 3% VOLTAGE DROP. CONTRACTOR MAY DETERMINE ACTUAL LENGTH OF BRANCH CIRCUITS AND MAY ADJUST BRANCH CIRCUIT CONDUCTOR SIZES ACCORDINGLY TO MAINTAIN A VOLTAGE DROP OF NOT LESS THAN 3% FOR LOADS SERVED, BUT WILL NOT SIZE THE CONDUCTORS LESS THAN INDICATED ABOVE. CONTRACTOR SHALL PROVIDE WRITTEN VOLTAGE DROP CALCULATIONS TO THE ENGINEER OF RECORD FOR REVIEW PRIOR TO INSTALLATION.
AutoCAD SHX Text BRANCH CIRCUIT (CONDUIT AND WIRING) CONCEALED ABOVE CEILING OR IN WALL, WITH NUMBER OF CONDUCTORS INDICATED. ( V ) INDICATES GREEN GROUNDING CONDUCTOR. SMALL ( ) INDICATES PHASE CONDUCTOR(S), OR SWITCHLEGS. LARGER ( ) INDICATES NEUTRAL CONDUCTOR(S). BRANCH CONDUCTORS SHALL BE SIZED PER THE HOMERUN CIRCUIT, UNLESS NOTED OTHERWISE ON THE PLANS OR IN THE SPECIFICATIONS. MINIMUM SIZE FOR CONDUIT IS 1/2". IF BRANCH CIRCUIT IS NOT SHOWN ON PLAN, CONDUCTORS FOR LIGHTING CIRCUITS SHALL BE ONE (1) PHASE AND ONE (1) NEUTRAL CONDUCTOR ( ) OR, FOR POWER CIRCUIT, ONE (1) PHASE, ONE (1) NEUTRAL AND ONE (1) GROUND ( V). WHERE NO CONDUIT AND/OR WIRING IS WHERE NO CONDUIT AND/OR WIRING IS SHOWN BETWEEN RECEPTACLES, ASSUME A SINGLE PHASE CONDUCTOR, NEUTRAL AND GROUND FOR CIRCUIT. .
AutoCAD SHX Text
LA-1
AutoCAD SHX Text
AutoCAD SHX Text V
AutoCAD SHX Text
AutoCAD SHX Text
#10 AWG
AutoCAD SHX Text V
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text BRANCH CIRCUIT (CONDUIT AND WIRING) CONCEALED BENEATH SLAB. BRANCH CONDUCTORS SHALL BE SIZED PER THE HOMERUN CIRCUIT, UNLESS NOTED OTHERWISE ON THE PLANS OR IN THE SPECIFICATIONS. SEE HOMERUN NOTE ABOVE. MINIMUM SIZE CONDUIT IS 3/4". IF NOT INDICATED, CIRCUIT IS ONE (1) PHASE CONDUCTOR, ONE (1) NEUTRAL CONDUCTOR, AND ONE (1) GREEN GROUNDING CONDUCTOR.
AutoCAD SHX Text LIGHTING FIXTURE SCHEDULE NOTES: 1. ALL FIXTURE SYMBOLS WITH SUFFIX OF "1" (e.g. A1, B1) SHALL BE EQUIPPED WITH AN EMERGENCY BALLAST. ALL FIXTURES INDICATED WITH AN EMERGENCY BALLAST SHALL HAVE THE EMERGENCY ALL FIXTURE SYMBOLS WITH SUFFIX OF "1" (e.g. A1, B1) SHALL BE EQUIPPED WITH AN EMERGENCY BALLAST. ALL FIXTURES INDICATED WITH AN EMERGENCY BALLAST SHALL HAVE THE EMERGENCY BALLAST INSTALLED IN THE FIXTURE AS COMPLETE UNITS, UNLESS NOTED OTHERWISE ON THE PLANS, IN THE SPECIFICATIONS, OR IN THE LUMINAIRE DESCRIPTION. PROVIDE AN UNSWITCHED HOT LEG IN ADDITION TO ANY SWITCHED HOT LEG INDICATED ON PLANS. PROVIDE BODINE EMERGENCY BALLAST, OR EQUAL. SEE SPECIFICATIONS FOR LUMEN REQUIREMENTS. 2. IF SHOWN ON PLANS AS CEILING MOUNTED EXIT SIGN, AND CEILING HEIGHT IS GREATER THAN 9'-0", MOUNT EXIT SIGNS CENTER LINE 12" ABOVE DOOR FRAME, OR 7'-6" A.F.F. ON WALL. IF SHOWN ON PLANS AS CEILING MOUNTED EXIT SIGN, AND CEILING HEIGHT IS GREATER THAN 9'-0", MOUNT EXIT SIGNS CENTER LINE 12" ABOVE DOOR FRAME, OR 7'-6" A.F.F. ON WALL. 3. FIXTURE MANUFACTURERS SHOWN REPRESENT MINIMUM QUALITY. EQUALS MAY BE PROVIDED. FIXTURE MANUFACTURERS SHOWN REPRESENT MINIMUM QUALITY. EQUALS MAY BE PROVIDED. 4. VERIFY AND PROVIDE MOUNTING HARDWARE FOR ALL FIXTURES AS NECESSARY FOR A COMPLETE SYSTEM. VERIFY AND PROVIDE MOUNTING HARDWARE FOR ALL FIXTURES AS NECESSARY FOR A COMPLETE SYSTEM. 5. ALL EXIT SIGNS, EMERGENCY BATTERY LIGHTS, AND STAIRWELL FIXTURES SHALL BE UNSWITCHED. ALL EXIT SIGNS, EMERGENCY BATTERY LIGHTS, AND STAIRWELL FIXTURES SHALL BE UNSWITCHED. 6. FIXTURE WHIPS SHALL BE A MINIMUM OF #14 AWG. FIXTURE WHIPS SHALL BE A MINIMUM OF #14 AWG. 7. VERIFY ALL COLORS AND FINISHES PRIOR TO ORDERING. VERIFY ALL COLORS AND FINISHES PRIOR TO ORDERING. 8. COLOR TEMPERATURE SHALL BE MINIMUM OF 3500K. COLOR TEMPERATURE SHALL BE MINIMUM OF 3500K. 9. DEPTH OF FIXTURES HAS BEEN COORDINATED WITH OTHER TRADES TO ENSURE THEY WILL FIT. IF OTHER LUMINAIRE COMPANY FIXTURES ARE SUBMITTED THEY MUST BE EQUAL RELATIVE TO DEPTH. DEPTH OF FIXTURES HAS BEEN COORDINATED WITH OTHER TRADES TO ENSURE THEY WILL FIT. IF OTHER LUMINAIRE COMPANY FIXTURES ARE SUBMITTED THEY MUST BE EQUAL RELATIVE TO DEPTH. 10. ALL FIXTURES WITH SYMBOL " " ON PLANS SHALL HAVE EMERGENCY BATTERY PACK FOR ILLUMINATION OF MEANS OF EGRESS. ALL FIXTURES WITH SYMBOL " " ON PLANS SHALL HAVE EMERGENCY BATTERY PACK FOR ILLUMINATION OF MEANS OF EGRESS. 11. COORDINATE ALL EXTERIOR LIGHTING FIXTURE LOCATIONS WITH ARCHITECTURAL ELEVATIONS PRIOR TO ROUGH-IN. COORDINATE ALL EXTERIOR LIGHTING FIXTURE LOCATIONS WITH ARCHITECTURAL ELEVATIONS PRIOR TO ROUGH-IN. 12. ALL EXTERIOR FIXTURES SHALL HAVE A GREY/SILVER FINISH.ALL EXTERIOR FIXTURES SHALL HAVE A GREY/SILVER FINISH.
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
VOLTS
AutoCAD SHX Text
TYPE- WATTS
AutoCAD SHX Text
LUMINAIRE DESCRIPTION
AutoCAD SHX Text
MANUFAC.
AutoCAD SHX Text
CATALOG NO.
AutoCAD SHX Text
HEIGHT
AutoCAD SHX Text
MOUNTING
AutoCAD SHX Text SYMBOL IDENTIFIES A CAMERA LOCATION. JUNCTION BOX AND CONDUIT WITH PULLSTRING PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. CAMERA AND CABLING PROVIDED BY OTHERS.
AutoCAD SHX Text
AutoCAD SHX Text B1
AutoCAD SHX Text
LED
AutoCAD SHX Text 23W
AutoCAD SHX Text
4' LED, ACRYLIC LENS, 3000 LUMENS, 4000K CCT, 80 CRI, 0-10V
AutoCAD SHX Text
DIMMING, WITH EMERGENCY BATTERY-1400 LUMENS, LOW MOUNT 360%%D
AutoCAD SHX Text
LITHONIA
AutoCAD SHX Text
FEM-L48-IMAFD-MD-120-GZ10-
AutoCAD SHX Text
40K-80CRI-E15WCP-WLFEND-
AutoCAD SHX Text 5.7"
AutoCAD SHX Text
CEILING MOUNT
AutoCAD SHX Text
MSL10NWL DSCNWL
AutoCAD SHX Text
INTEGRAL MOTION SENSOR, WET LOCATION, ON/OFF OPERATION FOR
AutoCAD SHX Text
MOTION SENSING, OVERRIDE OFF DUE TO DAYLIGHT.
AutoCAD SHX Text
AutoCAD SHX Text REPRODUCTION OR COPY EPRODUCTION OR COPY PRODUCTION OR COPY RODUCTION OR COPY ODUCTION OR COPY DUCTION OR COPY UCTION OR COPY CTION OR COPY TION OR COPY ION OR COPY ON OR COPY N OR COPY OR COPY OR COPY R COPY COPY COPY OPY PY Y OF THIS DRAWING IN F THIS DRAWING IN THIS DRAWING IN THIS DRAWING IN HIS DRAWING IN IS DRAWING IN S DRAWING IN DRAWING IN DRAWING IN RAWING IN AWING IN WING IN ING IN NG IN G IN IN IN N WHOLE OR PART SHALL HOLE OR PART SHALL OLE OR PART SHALL LE OR PART SHALL E OR PART SHALL OR PART SHALL OR PART SHALL R PART SHALL PART SHALL PART SHALL ART SHALL RT SHALL T SHALL SHALL SHALL HALL ALL LL L NOT BE USED ON ANY OT BE USED ON ANY T BE USED ON ANY BE USED ON ANY BE USED ON ANY E USED ON ANY USED ON ANY USED ON ANY SED ON ANY ED ON ANY D ON ANY ON ANY ON ANY N ANY ANY ANY NY Y OTHER PROJECT AND IS THER PROJECT AND IS HER PROJECT AND IS ER PROJECT AND IS R PROJECT AND IS PROJECT AND IS PROJECT AND IS ROJECT AND IS OJECT AND IS JECT AND IS ECT AND IS CT AND IS T AND IS AND IS AND IS ND IS D IS IS IS S TO BE RETURNED UPON O BE RETURNED UPON BE RETURNED UPON BE RETURNED UPON E RETURNED UPON RETURNED UPON RETURNED UPON ETURNED UPON TURNED UPON URNED UPON RNED UPON NED UPON ED UPON D UPON UPON UPON PON ON N REQUEST. ALL EQUEST. ALL QUEST. ALL UEST. ALL EST. ALL ST. ALL T. ALL . ALL ALL ALL LL L INFORMATION CONTAINED NFORMATION CONTAINED FORMATION CONTAINED ORMATION CONTAINED RMATION CONTAINED MATION CONTAINED ATION CONTAINED TION CONTAINED ION CONTAINED ON CONTAINED N CONTAINED CONTAINED CONTAINED ONTAINED NTAINED TAINED AINED INED NED ED D IN THIS DRAWING IS N THIS DRAWING IS THIS DRAWING IS THIS DRAWING IS HIS DRAWING IS IS DRAWING IS S DRAWING IS DRAWING IS DRAWING IS RAWING IS AWING IS WING IS ING IS NG IS G IS IS IS S COPYRIGHTED AS OF THE OPYRIGHTED AS OF THE PYRIGHTED AS OF THE YRIGHTED AS OF THE RIGHTED AS OF THE IGHTED AS OF THE GHTED AS OF THE HTED AS OF THE TED AS OF THE ED AS OF THE D AS OF THE AS OF THE AS OF THE S OF THE OF THE OF THE F THE THE THE HE E DATE NOTED.ATE NOTED.TE NOTED.E NOTED. NOTED.NOTED.OTED.TED.ED.D..
AutoCAD SHX Text
PROFESSIONAL STAMP
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text B
AutoCAD SHX Text rumfield
AutoCAD SHX Text HAROLD C. BRUMFIELD, JR. CSI, CCCA, AIA, NCARB No. 25189
AutoCAD SHX Text W. RANDY WARD AIA, LEED AP, MS. Lic. No. 2539
AutoCAD SHX Text 1030 North Park Drive, Ste A Ridgeland, Mississippi 39157
AutoCAD SHX Text
JOB NUMBER
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text W
AutoCAD SHX Text a
AutoCAD SHX Text
SSOCIATES
AutoCAD SHX Text a
AutoCAD SHX Text RCHITECTs
AutoCAD SHX Text Tel #: (601) 982-0341 Fax #: (601) 899-4799
AutoCAD SHX Text
DRAWN BY: CHECKED BY: DATE:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
OWNER
AutoCAD SHX Text W
AutoCAD SHX Text ard
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
HCC PROJECT #3157
AutoCAD SHX Text
RAYMOND, MISSISSIPPI
AutoCAD SHX Text
HINDS COMMUNITY COL.
AutoCAD SHX Text
STRUC. REPAIRS/ADDITIONS
AutoCAD SHX Text
2018 SHEFFIELD-WOOLLEY
AutoCAD SHX Text 18-040
AutoCAD SHX Text 12/11/2019
AutoCAD SHX Text
SRA
AutoCAD SHX Text
SRA
AT FIRST FLOOR - ELECTRICAL - PHASE I
SOUTH STAIR PLAN
AT SECOND FLOOR -
SOUTH STAIR PLAN
ELECTRICAL - PHASE I
AT THIRD FLOOR -
SOUTH STAIR PLAN
ELECTRICAL - PHASE I
AT FOURTH FLOOR -
SOUTH STAIR PLAN
ELECTRICAL - PHASE I
AT MAIN ROOF -
SOUTH STAIR PLAN
ELECTRICAL - PHASE I
NORTH STAIR PLAN AT FOURTH FLOOR - ELECTRICAL - PHASE II
NORTH STAIR PLAN AT THIRD FLOOR - ELECTRICAL - PHASE II
NORTH STAIR PLAN AT SECOND FLOOR - ELECTRICAL - PHASE II
NORTH STAIR PLAN AT FIRST FLOOR - ELECTRICAL - PHASE II
S H
EF
FI
EL
D
-W O
O
LL
EY
(R
AY
M
ON
D
CA
M
PU
S) R
A Y
M O
N D
, M
IS
SI
SS
IP
PI
(H C
C P
R O
JE
C
T #3
7)
ST
R
U C
TU
R
A L
R
EP
A
IR
S/ A
D D
IT
IO
N S
H
IN
D S
C O
M M
U N
IT
Y
C O
LL
EG
E (C
O M
M U
N
IT
Y C
O
LL
EG
E
B O
A R
D
1900 Lakeland Drive
Jackson, MS 39216
(601) 362-6478
Project Number :
EDMONDS
Trusted Engineering Solutions www.edmondsengineering.com
JAN18057
20238
S
H
A
N
E
AR
M
O
U
R
P
RO
F
E
S
S
I
O
N A
L
L
I C
E
N
S
E
D
ENGINEER
STATE OF MISS ISSIPP
I
E1.1
NTS
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text V
AutoCAD SHX Text
AutoCAD SHX Text V
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B1
AutoCAD SHX Text
AutoCAD SHX Text B1
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text V
AutoCAD SHX Text
AutoCAD SHX Text V
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B1
AutoCAD SHX Text
AutoCAD SHX Text B1
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text V
AutoCAD SHX Text
AutoCAD SHX Text V
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B1
AutoCAD SHX Text
AutoCAD SHX Text B1
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text V
AutoCAD SHX Text
AutoCAD SHX Text V
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B1
AutoCAD SHX Text
AutoCAD SHX Text B1
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text V
AutoCAD SHX Text
AutoCAD SHX Text V
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B1
AutoCAD SHX Text
AutoCAD SHX Text B1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text KEYED NOTES: CIRCUIT NEW LIGHTS TO EXISTING LIGHTING CIRCUITS THAT FED THE OLD LIGHTS.
AutoCAD SHX Text GENERAL DEMOLITION NOTES: A. SEE THE ARCHITECTURAL DEMOLITION PLANS FOR AREAS TO BE SEE THE ARCHITECTURAL DEMOLITION PLANS FOR AREAS TO BE DEMOLISHED. B. IN THE AREAS SPECIFICALLY IDENTIFIED OR DESIGNATED BY THE IN THE AREAS SPECIFICALLY IDENTIFIED OR DESIGNATED BY THE ARCHITECTURAL DEMOLITION PLAN TO BE DEMOLISHED, DISCONNECT AND REMOVE ALL EXISTING LIGHTING FIXTURES, ELECTRICAL EQUIPMENT, SWITCHES, RECEPTACLES, EXPOSED CONDUIT, SURFACE AND FLUSH MOUNTED DEVICE BOXES, PLATES, ETC. REMOVE ALL WIRING FROM EXISTING CONDUIT, CUT BACK, CAP AND ABANDON ALL CONCEALED CONDUIT. C. MAINTAIN EXISTING FEEDERS AND EXISTING SWITCHING SCHEMES FOR MAINTAIN EXISTING FEEDERS AND EXISTING SWITCHING SCHEMES FOR THE NEW LIGHTS. D. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL BRANCH CIRCUITS MAINTAIN AND RESTORE, IF INTERRUPTED, ALL BRANCH CIRCUITS AND FEEDERS PASSING THROUGH RENOVATED AREAS AND SERVING UNDISTURBED AREAS. E. THE OWNERS ARE TO HAVE THE RIGHT-OF-FIRST-REFUSAL FOR ALL THE OWNERS ARE TO HAVE THE RIGHT-OF-FIRST-REFUSAL FOR ALL DEMOLISHED LIGHTING FIXTURES AND DEVICES. F. EXISTING LENGTHS OF STRAIGHT CONDUIT, FOUND TO BE SOUND AND EXISTING LENGTHS OF STRAIGHT CONDUIT, FOUND TO BE SOUND AND RE-USABLE, MAY BE REUSED AT THE CONTRACTOR'S OPTION. G. ALL OTHER DEMOLISHED MATERIALS SHALL BE REMOVED FROM THE ALL OTHER DEMOLISHED MATERIALS SHALL BE REMOVED FROM THE JOB SITE AND ARE SUBJECT TO THE DEMOLITION DIRECTIVE ISSUED BY THE ARCHITECT. H. DISPOSAL OF MATERIALS REMOVED FROM THE JOB SITE DEEMED AS DISPOSAL OF MATERIALS REMOVED FROM THE JOB SITE DEEMED AS HAZARDOUS INCLUDING, BUT NOT EXCLUSIVELY LIMITED TO, THE FOLLOWING: FLUORESCENT LAMPS, COMPACT FLUORESCENT LAMPS, HIGH INTENSITY DISCHARGE LAMPS AND ELECTRICAL POWER TRANSFORMERS CONTAINING P.C.B.'S SHALL BE DISPOSED OF IN COMPLIANCE WITH THE RESOURCE CONSERVATION RECOVERY ACT (R.C.R.A.), SUBTITLE "C".
AutoCAD SHX Text GENERAL NOTES: A. CIRCUITS SHOWN ARE FOR SEPARATION ONLY. CIRCUITS SHOWN ARE FOR SEPARATION ONLY. B. ALL NEW BREAKERS SHALL BE FULLY COMPATIBLE ALL NEW BREAKERS SHALL BE FULLY COMPATIBLE WITH AND MATCH THE AIC RATING OF THE PANEL IN WHICH IT IS INSTALLED.
AutoCAD SHX Text
AutoCAD SHX Text REPRODUCTION OR COPY EPRODUCTION OR COPY PRODUCTION OR COPY RODUCTION OR COPY ODUCTION OR COPY DUCTION OR COPY UCTION OR COPY CTION OR COPY TION OR COPY ION OR COPY ON OR COPY N OR COPY OR COPY OR COPY R COPY COPY COPY OPY PY Y OF THIS DRAWING IN F THIS DRAWING IN THIS DRAWING IN THIS DRAWING IN HIS DRAWING IN IS DRAWING IN S DRAWING IN DRAWING IN DRAWING IN RAWING IN AWING IN WING IN ING IN NG IN G IN IN IN N WHOLE OR PART SHALL HOLE OR PART SHALL OLE OR PART SHALL LE OR PART SHALL E OR PART SHALL OR PART SHALL OR PART SHALL R PART SHALL PART SHALL PART SHALL ART SHALL RT SHALL T SHALL SHALL SHALL HALL ALL LL L NOT BE USED ON ANY OT BE USED ON ANY T BE USED ON ANY BE USED ON ANY BE USED ON ANY E USED ON ANY USED ON ANY USED ON ANY SED ON ANY ED ON ANY D ON ANY ON ANY ON ANY N ANY ANY ANY NY Y OTHER PROJECT AND IS THER PROJECT AND IS HER PROJECT AND IS ER PROJECT AND IS R PROJECT AND IS PROJECT AND IS PROJECT AND IS ROJECT AND IS OJECT AND IS JECT AND IS ECT AND IS CT AND IS T AND IS AND IS AND IS ND IS D IS IS IS S TO BE RETURNED UPON O BE RETURNED UPON BE RETURNED UPON BE RETURNED UPON E RETURNED UPON RETURNED UPON RETURNED UPON ETURNED UPON TURNED UPON URNED UPON RNED UPON NED UPON ED UPON D UPON UPON UPON PON ON N REQUEST. ALL EQUEST. ALL QUEST. ALL UEST. ALL EST. ALL ST. ALL T. ALL . ALL ALL ALL LL L INFORMATION CONTAINED NFORMATION CONTAINED FORMATION CONTAINED ORMATION CONTAINED RMATION CONTAINED MATION CONTAINED ATION CONTAINED TION CONTAINED ION CONTAINED ON CONTAINED N CONTAINED CONTAINED CONTAINED ONTAINED NTAINED TAINED AINED INED NED ED D IN THIS DRAWING IS N THIS DRAWING IS THIS DRAWING IS THIS DRAWING IS HIS DRAWING IS IS DRAWING IS S DRAWING IS DRAWING IS DRAWING IS RAWING IS AWING IS WING IS ING IS NG IS G IS IS IS S COPYRIGHTED AS OF THE OPYRIGHTED AS OF THE PYRIGHTED AS OF THE YRIGHTED AS OF THE RIGHTED AS OF THE IGHTED AS OF THE GHTED AS OF THE HTED AS OF THE TED AS OF THE ED AS OF THE D AS OF THE AS OF THE AS OF THE S OF THE OF THE OF THE F THE THE THE HE E DATE NOTED.ATE NOTED.TE NOTED.E NOTED. NOTED.NOTED.OTED.TED.ED.D..
AutoCAD SHX Text
PROFESSIONAL STAMP
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text B
AutoCAD SHX Text rumfield
AutoCAD SHX Text HAROLD C. BRUMFIELD, JR. CSI, CCCA, AIA, NCARB No. 25189
AutoCAD SHX Text W. RANDY WARD AIA, LEED AP, MS. Lic. No. 2539
AutoCAD SHX Text 1030 North Park Drive, Ste A Ridgeland, Mississippi 39157
AutoCAD SHX Text
JOB NUMBER
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text W
AutoCAD SHX Text a
AutoCAD SHX Text
SSOCIATES
AutoCAD SHX Text a
AutoCAD SHX Text RCHITECTs
AutoCAD SHX Text Tel #: (601) 982-0341 Fax #: (601) 899-4799
AutoCAD SHX Text
DRAWN BY: CHECKED BY: DATE:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
OWNER
AutoCAD SHX Text W
AutoCAD SHX Text ard
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
HCC PROJECT #3157
AutoCAD SHX Text
RAYMOND, MISSISSIPPI
AutoCAD SHX Text
HINDS COMMUNITY COL.
AutoCAD SHX Text
STRUC. REPAIRS/ADDITIONS
AutoCAD SHX Text
2018 SHEFFIELD-WOOLLEY
AutoCAD SHX Text 18-040
AutoCAD SHX Text 12/11/2019
AutoCAD SHX Text
SRA
AutoCAD SHX Text
SRA
AutoCAD SHX Text 01 / 21 / 2O20
AutoCAD SHX Text
SOUTH STAIR LOCATION
KEY PLAN
| JAN18057 - Sheffield Wooley Dorm Mechanical Drawings REBID 2.pdf |
| Sheets and Views |
| SITE PLAN-MS1.1 |
| MECH-MD1.1 |
| MECH-MD1.2 |
| MECH-M1.1 |
| MECH-M1.2 |
| MECH-M1.3 |
| JAN18057 - Sheffield Wooley Dorm Electrical Drawings REBID 2.pdf |
| Sheets and Views |
| JAN18057-E0.1-E0.1 |
| JAN18057-E1.1-E1.1 |
| JAN18057-E1.2-E1.2 |
File details come from the government source that posted it. Updated .