3-Rose Park Civil Pond Plan.pdf
PDF 896 KB Posted
- Attached to
- Rose Park Golf Course Irrigation and Turf Reduction / Nibley Park Golf Course Irrigation
- Solicitation number
- PRK23041 / PRK26019
- Issued by
- Utah
About this file
This civil site plan document pertains to the Rose Park Golf Course Irrigation System Turf Reduction project under the Salt Lake City Corporation's Department of Public Lands, Parks Division and Golf Division. The project encompasses the installation of a new irrigation system infrastructure including excavation and construction of a two-stage settling pond with clay-sealed liners, inlet and outlet structures, a new pump station and wet well, irrigation mainline with service feeds and laterals, and associated electrical work and piping. The plan is preliminary and not for construction, identified as Sheet C201 with project number PRK23041. The site plan indicates existing infrastructure to be protected, including a 48-inch dual-barrel Salt Lake City Public Utilities sanitary sewer forcemain with a required minimum 25-foot setback from the pond edge, existing sanitary sewer mains, and a storm drain system. Key design specifications include a Jordan River pump discharge with an invert elevation of 4212 feet, a 24-inch HDPE storm pipe, 6-inch HDPE waterline, and a proposed irrigation service pump location, with all utilities coordinated to maintain appropriate vertical clearances and separation distances.
The document provides horizontal scale references at 1 inch equals 40 feet and includes detailed elevation data for existing structures such as sanitary sewer manhole rims and inverts. The plan designates a proposed transformer location and electrical service coordination with the local utility provider's infrastructure master plan. The project involves coordination with Salt Lake City Public Utilities for the primary service and protection of existing sanitary infrastructure in place. No pricing, funding sources, bid dates, or contract award information is contained within this preliminary civil site plan document.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE
P R
E
LI
M
IN
A R
Y N
O T
F O
R C
O N
S T
R U
C T
IO
N
PUBLIC LANDS
GOLF DIVISION
PARKS DIVISION
SALT LAKE CITY
CORPORATION
DEPARTMENT OF PUBLIC
LANDS
ROSE PARK
GOLF COURSE
IRRIGATION SYSTEM
TURF REDUCTION
CIVIL SITE PLAN
POND INSERT
C201
AutoCAD SHX Text
TL
AutoCAD SHX Text
IR
AutoCAD SHX Text S
AutoCAD SHX Text
SDVT
AutoCAD SHX Text D
AutoCAD SHX Text
TELEPHONE BOX
AutoCAD SHX Text
EXIST. SSMH RIM=4216.70 INV. W (44")=4201.98 INV. E (44")=4201.92
AutoCAD SHX Text
EXIST. SD VAULT RIM=4215.86
AutoCAD SHX Text
EXIST. SDMH RIM=4216.30
AutoCAD SHX Text
HORIZONTAL:
AutoCAD SHX Text
AutoCAD SHX Text 1" = 40'
AutoCAD SHX Text 20'
AutoCAD SHX Text 40'
AutoCAD SHX Text 60'
AutoCAD SHX Text
BINDING ORDER
AutoCAD SHX Text
PROJECT OWNER:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
DRAWING FILE:
AutoCAD SHX Text
FILE #:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
MARK
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT IDENTIFICATION:
AutoCAD SHX Text
PREPARED BY:
AutoCAD SHX Text
COPYRIGHT:
AutoCAD SHX Text
PREPARER CONSULTANTS:
AutoCAD SHX Text
SHEET IDENTIFIER:
AutoCAD SHX Text
PROFESSIONAL SEAL:
AutoCAD SHX Text
PROJECT #:
AutoCAD SHX Text
CONTRACT #:
AutoCAD SHX Text
PREPARER #:
AutoCAD SHX Text
1386 NORTH REDWOOD ROAD SALT LAKE CITY, UTAH 84116 WWW.SLCGOV.COM
AutoCAD SHX Text 1965 W 500 S SALT LAKE CITY, UTAH 84104 TELEPHONE: 801-535-7961 FAX: 801-535-6093 WWW.SLCGOV.COM
AutoCAD SHX Text
SLC CORP.
AutoCAD SHX Text
PRK23041
AutoCAD SHX Text
AS-BUILT LOCATION OF 48" DUAL-BARREL SLCPU SANITARY SEWER FORCEMAIN
AutoCAD SHX Text
MIN 25' FROM EDGE OF FORCEMAIN TO TOP OF POND
AutoCAD SHX Text A
AutoCAD SHX Text C300
AutoCAD SHX Text
EXISTING SANITARY SEWER MAIN - TO BE PROTECTED IN PLACE
AutoCAD SHX Text PROPOSED JORDAN RIVER PUMP DISCHARGE. PROVIDE MINIMUM 18" VERTICAL CLEARANCE FROM EXISTING SANITARY SEWER WITH APPROXIMATE CROWN ELEV: 4206.13'
AutoCAD SHX Text
COORDINATE WITH RMP FOR NEW PRIMARY SERVICE SEE ELECTRICAL SHEETS
AutoCAD SHX Text
PROPOSED TRANSFORMER LOCATION SEE ELECTRICAL SHEETS
AutoCAD SHX Text
JORDAN RIVER PUMP DISCHARGE. INVERT ELEV: 4212'
AutoCAD SHX Text ELECTRICAL LINE TO BE PLACED ABOVE EXISTING SANITARY SEWER WITH APPROXIMATE CROWN ELEV: 4206.17'. PROVIDE 1' MINIMUM SEPERATION SEE ELECTRICAL SHEETS.
AutoCAD SHX Text 6" HDPE DR-17 WATERLINE. PROVIDE MINIMUM 18" VERTICAL CLEARANCE FROM EXISTING SANITARY SEWER WITH APPROXIMATE CROWN ELEV: 4206.15'
AutoCAD SHX Text
24" HDPE STORM PIPE
AutoCAD SHX Text
HEADWALL AND TRASH RACK. INV ELEV: 4212.5' SEE DETAIL SHEET C700.
AutoCAD SHX Text D
AutoCAD SHX Text C300
AutoCAD SHX Text
PROPOSED IRRIGATION SERVICE PUMP LOCATION