This document is a revised inspection report of asbestos-containing building materials (ACBM) and lead-based paint in Building #882 at Malmstrom Air Force Base in Great Falls, Montana, prepared by Maxim Technologies, Inc. for CTA Architects Engineers on April 18, 1997.
The asbestos inspection, conducted January 13-14, 1997, identified four homogeneous areas of ACBM: mastic under 12"x12" tan floor tile (5% chrysotile), mastic under 12"x12" brown floor tile (15% chrysotile), cement asbestos board/transite walls (70% chrysotile), and built-up roofing materials (3% chrysotile). The report categorizes these materials under AHERA and NESHAP regulations and recommends that identified ACMs be removed by qualified abatement contractors prior to renovation activities. Detailed asbestos abatement specifications should be prepared by an accredited asbestos abatement designer. The lead-based paint inspection, conducted January 13-14, 1997, identified one homogeneous area containing lead-based paint on exterior concrete traffic bollards with lead concentration exceeding 1.0 mg/cm². The report recommends that workers performing paint removal or surface preparation on the traffic bollards receive OSHA lead-in-construction standard training, wear appropriate personal protective equipment including respirators and disposable coveralls, and properly dispose of paint chips and dust using HEPA-equipped vacuums with TCLP testing to determine appropriate disposal methods. The building is a single-story concrete masonry unit structure approximately 16,512 square feet, with interior carpet over vinyl tile floors, sheetrock, and CMU or cement asbestos board walls.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REVISED
INSPECTION REPORT
OF
ASBESTOS AND LEAD-BASED PAINT
BUILDING MATERIALS
BUILDING #882
MALMSTROM AIR FORCE BASE
GREAT FALLS, MONTANA
REVISED
INSPECTION REPORT
OF
ASBESTOS AND LEAD-BASED PAINT
BUILDING MATERIALS
BUILDING #882
MALMSTROM AIR FORCE BASE
GREAT FALLS, MONTANA
Prepared for:
CTA ARCHITECTS ENGINEERS
P. O. BOX 1439
BILLINGS, MONTANA 59103
Prepared by:
MAXIM TECHNOLOGIES, INC.
600 SOUTH 25TH STREET
BILLINGS, MONTANA
Project No. 5510702058
April 18, 1997
EXECUTIVE SUMMARY
1.0 INTRODUCTION.
2.0
3.0
TABLE OF CONTENTS
Page No.
i
ASBESTOS INSPECTION.
2.1 ASBESTOS OVERVIEW
2.2 PROCEDURES 2
2.3
2.2.1 Inspection and Sampling.
2.2.2 Laboratory Analysis
2.2.3 АНERA and NESHAP Categories
2.2.4 Quality Assurance and Quality Control.
FINDINGS
2.3.1 Building Description. 7
2.3.2 Summary of Asbestos-Containing Building Materials. 8
2.4 RECOMMENDATIONS 9
LEAD-BASED PAINT INSPECTION 10
3.1 PROCEDURES. 10
3.1.1 XRF Sampling Methodology.
3.1.2 Quality Assurance and Quality Control.
.10
.11
3.2 FINDINGS .11
3.2.1 Building Description.
3.2.2 Summary of Suspect Lead-Based Paint: XRF Screening.
.11
.12
3.3 RECOMMENDATIONS. .13
3.3.1 General Recommendations
3.3.2 Specific Recommendations
.13
.13
4.0 LIMITATIONS
LIST OF APPENDICES
APPENDIX A REGULATORY REVIEW FOR ASBESTOS AND LEAD-BASED PAINT MATERIALS
APPENDIX B ACBM BULK SAMPLE LABORATORY RESULTS
APPENDIX C LEAD-BASED PAINT XRF RESULTS
APPENDIXD MAXIM TECHNOLOGIES PERSONNEL AHERA CERTIFICATES
.14
File details come from the government source that posted it. Updated .