3-2-CS27005-27082310-Approved Plans.pdf

PDF 1 MB Posted

Attached to
DFCM Construction - Invitational - Department of Health and Human Services - Academy Square Access Control - Project #27082310
Solicitation number
CS27005
Issued by
Utah

About this file

This is an approved permit set of construction plans prepared by Envision Engineering for the Division of Facilities Construction and Management (DFCM) at the State of Utah, detailing the Academy Square Access Control System Upgrade project located at 950 East 25th Street in Ogden, Utah. The project involves replacing an aging access control system with a new Avigilon-based system featuring multiple access control panels, card readers, electronic door strikes, door position switches, and momentary contact buttons distributed across the first floor of the building. The construction plans include a cover sheet, symbols and notes, demolition system plan, and first floor system plan with detailed electrical specifications, riser diagrams, and door rough-in details. The project number is 27082310, and the permit set was issued on June 26, 2026, with code compliance review completed by Thomas Peterson on July 2, 2026. The contractor is responsible for pre-construction site visits, coordination with the access control system supplier, compliance with all electrical codes and specifications, and providing a complete operational system including 500 credential cards, network connections to the IT infrastructure, fire alarm integration, and proper labeling and seismic support of all equipment.

The construction cost estimate for this project is $80,000.00. This is an invitational bid opportunity limited to three pre-selected contractors: Convergint (contact Brian Lockwood), DSI (contact Curtis Fielding), and Harris (contact Kenny Snow). The project requires coordination between the electrical contractor and access control vendor to confirm final integration requirements, device locations, conduit routing, and conductor sizes prior to rough-in work. All existing access control equipment must be disconnected and removed or returned to the owner, with existing wiring remaining in place for reuse unless the access control system supplier determines incompatibility. The contractor must verify compatibility of existing wiring with the new system prior to bid submission and trace all affected circuits before demolition. The base bid excludes access control system installation, with system provision as an alternate bid item for specified doors.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NO. DATE REVISIONS

DFCM PROJECT NO:

A

1 2 3 4 5

1 2 3 4 5

27082310

CHECKED BY: SDK/DPW

DESIGNED BY: SDK

DRAWN BY: JDB

ENVISION PROJECT NO: 2026.107.00

DATE:

ISSUE:

JUNE 26, 2026

PERMIT SET

B

C

D

A

B

C

D

DF

CM

A

CA

DE

MY

S

QU

AR

E

AC

CE

SS

C

ON

TR

OL

S

YS

TE

M

UP

GR

AD

E

0 E

AS

T

TH

S

TR

EE

T

OG

DE

N, U

TA

H

6 7

E

F

E

F

6 7

Fil e N am e:

V:

\26

\20

-1

.00

DC

FS

Ac ad em y S qu ar e -

A cc es s C on tro ls\

_D wg s\E G0

.dw g L as t P lot ted : 2

6/0

6/2 6 @

5:

:51 P

M By

: S

CO

TT

.K

IN

GE

RY

240 E. MORRIS AVE, SUITE 200

SALT LAKE CITY, UT 84115

P (801) 534-1130 www.envisioneng.com

ENV: 2026-107.00

AGENCY APPROVAL STAMP

EG001

COVER SHEET

Vicinity Map

Site

DFCM ACADEMY SQUARE

ACCESS CONTROL SYSTEM UPGRADE

ENVISION ENGINEERING

240 EAST MORRIS AVENUE STE. 200

SALT LAKE CITY, UT 84115

P: (801) 534-1130

SKINGERY@ENVISIONENG.COM

CONTACT: SCOTT KINGERY

DFCM PROJECT NUMBER: 27082310 ISSUE TYPE: PERMIT SET ISSUE DATE: JUNE 26, 2026

950 EAST 25TH STREET

OGDEN, UTAH

DRAWING INDEX

EG001 COVER SHEET

EG101 SYMBOLS, NOTES, DETAILS AND RISERS

ED101 LEVEL 1 DEMOLITION SYSTEM PLAN

EY101 LEVEL 1 SYSTEM PLAN

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

REVIEWED FOR

CODE COMPLIANCE

THOMAS PETERSON

07/02/2026 http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com

NO. DATE REVISIONS

DFCM PROJECT NO:

A

1 2 3 4 5

1 2 3 4 5

27082310

CHECKED BY: SDK/DPW

DESIGNED BY: SDK

DRAWN BY: JDB

ENVISION PROJECT NO: 2026.107.00

DATE:

ISSUE:

JUNE 26, 2026

PERMIT SET

B

C

D

A

B

C

D

DF

CM

A

CA

DE

MY

S

QU

AR

E

AC

CE

SS

C

ON

TR

OL

S

YS

TE

M

UP

GR

AD

E

0 E

AS

T

TH

S

TR

EE

T

OG

DE

N, U

TA

H

6 7

E

F

E

F

6 7

Fil e N am e:

V:

\26

\20

-1

.00

DC

FS

Ac ad em y S qu ar e -

A cc es s C on tro ls\

_D wg s\E G1

.dw g L as t P lot ted : 2

6/0

6/2 6 @

5:

:54 P

M By

: S

CO

TT

.K

IN

GE

RY

240 E. MORRIS AVE, SUITE 200

SALT LAKE CITY, UT 84115

P (801) 534-1130 www.envisioneng.com

ENV: 2026-107.00

AGENCY APPROVAL STAMP

ARROWS: NUMBER OF ARROWS INDICATES NUMBER OF

CIRCUITS REQUIRED.

SHORT CROSS LINES: NUMBER OF SHORT CROSS LINES

INDICATES NUMBER OF PHASE, TRAVELER, AND/OR SWITCHED

CONDUCTORS REQUIRED IF GREATER THAN 1 (ONE).

LONG CROSS LINES: NUMBER OF LONG CROSS LINES

INDICATES NUMBER OF NEUTRAL CONDUCTORS REQUIRED

FOR MULTI-WIRE HOME RUNS.

EQUIPMENT GROUND AND ISOLATED GROUND CONDUCTORS:

EQUIPMENT GROUND AND ISOLATED GROUND CONDUCTORS

ARE NOT SHOWN, BUT ARE REQUIRED AS NOTED ON THE

DRAWINGS OR IN THE SPECIFICATIONS.

J

DESCRIPTIONSYMBOL REMARKS

1 CIRCUIT, 2 WIRE BRANCH CIRCUIT HOME RUN TO PANEL

2 CIRCUIT, 4 WIRE BRANCH CIRCUIT HOME RUN TO PANEL

3 CIRCUIT, 6 WIRE BRANCH CIRCUIT HOME RUN TO PANEL

MULTIPLE WIRE BRANCH CIRCUITING BETWEEN FIXTURES,

SWITCHES, DEVICES, ETC.

BRANCH CIRCUITING (U.N.O.) TURNED UP OR TOWARDS

OBSERVER.

BRANCH CIRCUITING (U.N.O.) TURNED DOWN OR AWAY FROM

OBSERVER.

BRANCH CIRCUITING (U.N.O.) CONTINUATION

CONDUIT STUB-IN

INCOMING SERVICE

JUNCTION BOX MOUNT AS NOTED. SUBSCRIPT 'F' INDICATES TO PROVIDE A

FLOOR BOX WITH BLANK COVERPLATE

BRANCH CIRCUITING SYMBOLS

CAP AND MARK

ELECTRICAL SYMBOL SCHEDULE GENERAL NOTES

1. MOUNT ALL OUTLETS, DEVICES, AND EQUIPMENT AT HEIGHTS INDICATED BELOW, UNLESS NOTED OTHERWISE ON THE DRAWINGS.

UNLESS NOTED OTHERWISE, HEIGHTS ARE GIVEN FROM FINISHED FLOOR TO CENTER OF OUTLET BOX.

2. WHERE OUTLETS, DEVICES, AND EQUIPMENT ARE NOTED BY SUBSCRIPTS, REFER TO ABBREVIATION SCHEDULE FOR DEFINED

REQUIREMENTS.

3. WHERE OUTLETS, DEVICES AND EQUIPMENT ARE NOTED BY THE SUBSCRIPT 'A', MOUNT AT 4" ABOVE COUNTER. IF COUNTER HAS A BACK SPLASH, MOUNT AT 4" ABOVE BACK SPLASH. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS AND COORDINATE WITH CASEWORK

SUPPLIER.

4. NOT ALL ELECTRICAL SYMBOLS MAY BE USED.

GENERAL PROJECT NOTES:

1. DIVISION 26 CONTRACTOR IS RESPONSIBLE FOR READING AND APPLYING WHAT IS IN THE

SPECIFICATIONS TO THIS PROJECT. ANYTHING THAT IS NOT INCLUDED ON THE PROJECT THAT IS

CALLED OUT IN THE SPECIFICATION SHALL BE LISTED ON THE SUBSTANTIAL COMPLETION

PUNCHLIST. THE CONTRACTOR WILL BE REQUIRED TO REMEDY THESE DEFICIENCIES. THERE WILL

BE NO EXCEPTIONS.

2. THE CONTRACTOR MAY SCHEDULE A PRE-CONSTRUCTION MEETING AT THEIR DISCRETION, WITH

THE ELECTRICAL ENGINEER AND OWNER TO REVIEW THE DRAWINGS AND SPECIFICATIONS. THE

MEETING SHALL BE A MAXIMUM OF ONE HOUR AND SHALL TAKE PLACE AT THE ENGINEER'S OFFICE

WHERE POSSIBLE.

3. THE FOLLOWING ITEMS ARE SOME OF THE REQUIREMENTS THAT ARE LISTED IN THE

SPECIFICATIONS. THESE ITEMS DO NOT REPRESENT ALL ITEMS AND THE CONTRACTOR IS

RESPONSIBLE FOR MEETING ALL REQUIREMENTS OF THE SPECIFICATIONS:

A. INSULATED THROAT CONNECTORS OR PLASTIC BUSHINGS SHALL BE UTILIZED FOR ALL

CONDUIT SIZES USED ON THIS PROJECT.

B. A DEDICATED NEUTRAL CONDUCTOR WILL BE PROVIDED FOR ALL LIGHTING AND POWER

CIRCUITS.

C. THE CONTRACTOR SHALL LABEL ALL ELECTRICAL EQUIPMENT AS IT IS CALLED OUT IN THE

SPECIFICATIONS.

D. THE CONTRACTOR SHALL PROVIDE SEISMIC SUPPORT AND BRACING FOR ALL ELECTRICAL

EQUIPMENT AS REQUIRED BY LOCAL AND NATIONAL CODE.

4. THE CONTRACTOR SHALL INSTALL THE WIRE SIZES AS CALLED OUT ON THE RISER DIAGRAMS AND

ELECTRICAL SPECIFICATIONS.

5. THE CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING THE BID, AND SHALL EXAMINE ALL PHYSICAL CONDITIONS WHICH MAY BE MATERIAL TO THE PERFORMANCE OF HIS WORK. NO EXTRA

PAYMENTS WILL BE ALLOWED TO THE CONTRACTOR AS A RESULT OF EXTRA WORK MADE

NECESSARY BY THEIR FAILURE TO DO SO. ANY CASE OF DISCREPANCY OR LACK OF CLARITY SHALL

BE PROMPTLY IDENTIFIED TO THE OWNER'S REPRESENTATIVE AND THE ENGINEER FOR

CLARIFICATION.

6. PROVIDE UPDATED, TYPED PANELBOARD SCHEDULE(S) TO REFLECT ALL THE CHANGES MADE, INCLUDING EXISTING LOADS. THE EXISTING LOADS SHALL BE NAMED THE SAME AS LISTED ON THE

EXISTING PANELBOARD SCHEDULE.

NOTE: NOT ALL ABBREVIATIONS MAY BE USED.

ABBREVIATION SCHEDULE

ABOVE COUNTER

AMP OR AMPS

ADJACENT

ABOVE FINISHED FLOOR

AUTHORITY HAVING JURISDICTION

ALUMINUM

AUTOMATIC TRANSFER SWITCH

AUXILIARY

AMERICAN WIRE GAUGE

BUILDING AUTOMATION SYSTEM

BUILDING

CONDUIT

CIRCUIT BREAKER

CIRCUIT

CEILING

CONVENIENCE OUTLETS

COPPER

DISTRIBUTED ANTENNA SYSTEM

EXISTING

EACH

EQUIPMENT GROUND

EQUIPMENT GROUNDING CONDUCTOR

ELECTRICAL

EMERGENCY

ELECTRIC METALLIC TUBING

ELECTRIC NONMETALLIC TUBING

EQUIPMENT

ELECTRIC WATER COOLER

EXPLOSION PROOF

FIRE ALARM

FIRE ALARM CONTROL PANEL

FULL LOAD AMPS

FLEXIBLE METAL CONDUIT

FIBER OPTIC

FREIGHT ON BOARD

FEED-THROUGH LUGS

GROUNDING ELECTRODE CONDUCTOR

GROUND CONDUCTOR

HAND-OFF-AUTO

HORSE POWER

INTERSYSTEM BONDING TERMINATION BAR

INTRUSION DETECTION

ISOLATED GROUND

INTERMEDIATE METAL CONDUIT

INSULATED

ISOLATED

KILO CIRCULAR MIL

KILO VOLT AMPERES

KILOWATTS

LIQUID-TIGHT NONMETAL CONDUIT

LONG-TIME, SHORT-TIME

A A

ADJ

AFF

AHJ

AL

ATS

AUX

AWG

BAS

BLDG

C

CB

CKT

CLG

CO

CU

DAS

(E)

EA

EG

EGC

ELEC

EM

EMT

ENT

EQUIP

EWC

EXP

FA

FACP

FLA

FMC

FO

FOB

FTL

GEC

GND

HOA

HP

IBT

ID

IG

IMC

INS

ISO

KCMIL

KVA

KW

LFNC

LS

LONG-TIME, SHORT-TIME INSTANTANEOUS

LONG-TIME, SHORT-TIME INSTANTANEOUS GROUND FAULT

LIGHTING

MAIN BONDING JUMPER

MINIMUM CIRCUIT AMPS

MAIN CIRCUIT BREAKER

MAIN LUGS ONLY

MEDIUM VOLTAGE

MICROWAVE

NORMALLY CLOSED

NATIONAL ELECTRIC CODE

NOT IN CONTRACT

NIGHT LIGHT

NORMALLY OPEN

ON CENTER(S)

OVER CURRENT PROTECTION

OVER CURRENT PROTECTION DEVICE

PUBLIC ADDRESS

PHASE

PHOTOVOLTAIC

POWER

QUANTITY

REMOVE

REFRIGERATOR

REQUIREMENTS

RIGID GALVANIZED CONDUIT

RIGID METAL CONDUIT

ROCKY MOUNTAIN POWER

RIGID NONMETALLIC CONDUIT

REMOVE AND RELOCATE

SYSTEM BONDING JUMPER

SECURITY CONTROL PANEL

SUB-FEED LUGS

SURGE PROTECTIVE DEVICE

SURGE SUPPRESSION

SUPPLY SIDE BONDING JUMPER

TELECOMMUNICATION GROUNDING BUS BAR

TELECOMMUNICATION MAIN GROUNDING BUS BAR

TAMPER RESISTANT

TELEPHONE TERMINAL BOARD

TYPICAL

UNDER FLOOR

UNDERGROUND

UNLESS NOTED OTHERWISE

UNIVERSAL SERIAL BUS

VIDEO SURVEILLANCE SYSTEM

WITH

WITHOUT

WEATHER PROOF

WEATHER RESISTANT

TRANSFORMER

LSI

LSIG

LTG

MBJ

MCA

MCB

MLO

MV

MW

NC

NEC

NIC

NL

NO

OC

OCP

OCPD

PA

PH

PV

PWR

QTY

R

REF

REQ

RGC

RMC

RMP

RNC

RR

SBJ

SCP

SFL

SPD

SS

SSBJ

TGB

TMGB

TR

TTB

TYP

UF

UG

UNO

USB

VSS

W/

WO/

WP

WR

XFMR

ACCESS CONTROL SYMBOLS

P K

M K

P R

M R

S

M

KP

MOUNTING REMARKSDESCRIPTIONSYMBOL

REX

D

REQUEST-TO-EXIT MOTION DETECTOR

ELECTROMAGNETIC DOOR STRIKE

MAGNETIC DOOR CONTACT SWITCH

MAGNETIC LOCK

KEYPAD

PROXIMITY CARD READER / KEYPAD

MAGNETIC STRIP CARD READER / KEYPAD

PROXIMITY CARD READER

MAGNETIC STRIP CARD READER

CEILING

DOOR

DOOR

DOOR

+48"

+48"

+48"

+48"

+48"

XX

E-1

E-2

TOP NUMBER INDICATES DETAIL NUMBER; BOTTOM

LETTER-NUMBER INDICATES WHERE DETAIL IS SHOWN.

E-3

AHU

TOP NUMBER ABBREVIATES EQUIPMENT NAME OR TYPE;

BOTTOM NUMBER INDICATES EQUIPMENT NUMBER. REFER TO

EQUIPMENT SCHEDULE.

USED TO DENOTE CHANGES EITHER ISSUED BY ADDENDUM OR

DURING CONSTRUCTION AND TO DENOTE RECORD DRAWING

CHANGES.

USED TO BREAK DRAWINGS.

DESCRIPTIONSYMBOL REMARKS

GENERAL SYMBOLS

KEYED NOTE

DETAIL REFERENCE

ELEVATION REFERENCE

SECTION REFERENCE

ARCHITECTURAL ROOM NUMBER

EQUIPMENT NAME / NUMBER

REVISION NUMBER

BREAKLINE

TOP NUMBER INDICATES SECTION NUMBER; BOTTOM

LETTER-NUMBER INDICATES WHERE SECTION IS SHOWN.

TOP NUMBER INDICATES ELEVATION NUMBER; BOTTOM

LETTER-NUMBER INDICATES WHERE ELEVATION IS SHOWN.

USED TO DENOTE AREAS, DEVICES, EQUIPMENT DETAILS, ETC.

AFFECTED BY REVISION.

REVISION CLOUD

WIRING DEVICE SYMBOLS

(5-20R)

J a

K

P

DIM

TIM

LV

a

3PM

3PN

DESCRIPTIONSYMBOL MOUNTING REMARKS

SUBSCRIPT KEYS SWITCH TO FIXTURES

CONTROLLED.

RATE DIMMER SWITCH FOR MAXIMUM

POSSIBLE WATTAGE

DUAL LEVEL SWITCH OUTBOARD LAMPS

SEPARATELY FROM INBOARD LAMPS.

REFER TO DETAIL UP-ON;

CENTER-NEUTRAL; DOWN-OFF

CEILING MOUNTED WITH SUBSCRIPT 'C';

WALL-MOUNTED WITH SUBSCRIPT 'W'

UP-ON; CENTER-OFF; DOWN-ON

RANGE -- NEMA 14-50R

DRYER -- NEMA 14-30R

SUBSCRIPT IN PARENTHESIS INDICATES

NEMA CONFIGURATION IF SHOWN. REFER

TO DRAWINGS AND/OR EQUIPMENT

SCHEDULES. CONFIRM EXACT

CONFIGURATION WITH OWNER PRIOR TO

INSTALLATION.

REFER TO DETAIL

4" ABOVE

BACKSPLASH

SINGLE-POLE TOGGLE SWITCH

SINGLE-POLE TOGGLE SWITCH

DOUBLE-POLE TOGGLE SWITCH

THREE-WAY TOGGLE SWITCH

FOUR-WAY TOGGLE SWITCH

KEY-OPERATED SINGLE-POLE TOGGLE SWITCH

SINGLE-POLE TOGGLE SWITCH WITH PILOT LIGHT

DIMMER SWITCH

TIMER SWITCH

(2) SINGLE-POLE TOGGLE SWITCH

LOW VOLTAGE MOMENTARY CONTACT SWITCH

3-POSITION MOMENTARY CONTACT SWITCH

3-POSITION MAINTAINED CONTACT SWITCH

OCCUPANCY SENSOR

SPLIT-WIRED DUPLEX RECEPTACLE

DUPLEX RECEPTACLE

FOURPLEX RECEPTACLE

SIMPLEX RECEPTACLE

125/250V RECEPTACLE

GROUND FAULT CIRCUIT INTERRUPTER DUPLEX RECEPTACLE

GROUND FAULT CIRCUIT INTERRUPTER FOURPLEX

RECEPTACLE

EMERGENCY DUPLEX RECEPTACLE

EMERGENCY FOURPLEX RECEPTACLE

MULTI-OUTLET ASSEMBLY

POWER / TELEPHONE POLE

CORD DROP WITH DUPLEX RECEPTACLE

SPECIAL PURPOSE OUTLET

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

AS NOTED

+18"

+18"

+18"

+18"

+18"

+18"

+18"

+18"

+18"

FLOOR/CEILING

+18"

OS WALL MOUNTED OCCUPANCY SENSOR SWITCH

DUAL RELAY WALL MOUNTED OCCUPANCY SENSOR SWITCH

+48"

+48"OS

SYMBOLS, NOTES,

DETAILS AND

RISERS

EG101

CR

ACCESS CONTROL SYSTEM EQUIPMENT LIST

SYMBOL DESCRIPTION MANUFACTURE MODEL REQUIREMENTS

ACCESS CONTROL SERVER

AVIGILON 12/14V 4-DOOR SMART HUB

ACC

PER MANUFACTURE REQUIREMENTS

4 DOOR POWER SUPPLY ACS ENCLOSURE

8 DOOR POWER SUPPLY ACS ENCLOSURE

CREDENTIAL READER HID SIGNO - 20 (MULLION)

SIGNO - 40 (SURFACE)

MOMENTARY DOOR RELEASE BUTTON ALARM CONTROLS TS-18

DURESS / PANIC BUTTON HONEYWELL 270RD

ACCESS CONTROL SYSTEM GENERAL NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

PROVIDE AVIGALON ACCESS CONTROL SYSTEM . REFER TO THE

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

CONFIRM ALL WIRING REQUIREMENTS WITH ACCESS CONTROL SYSTEM SUPPLIER AND

PROVIDE IN ACCORDANCE THEREWITH.

THE SYSTEM SHALL BE PROGRAMMED PER ALL OWNERS REQUIREMENTS. VERIFY PRIOR TO

ANY PROGRAMMING .

WIRING SHALL BE CONTINUOUS FROM ONE DEVICE TO ANOTHER. NO SPLICING IS ALLOWED.

PROVIDE ACCESS CONTROL MAP OF THE BUILDING SHOWING ALL ACCESS CONTROL SYSTEM

DEVICES , INCLUDING EXISTING . LOCATE MAP IN LOCATION AS DIRECTED BY THE OWNER.

ALL ACCESS CONTROL WIRING SHALL BE RUN IN CONDUIT. MINIMUM CONDUIT SIZE SHALL

BE 3/4", UNLESS NOTED OTHERWISE.

VERIFY ALL LOCATIONS OF ACCESS CONTROL DEVICES WITH THE OWNER PRIOR TO ANY

ROUGH-IN.

THE ACCESS CONTROL SYSTEM SUPPLIER SHALL PROVIDE COMPUTER DRAFTED SHOP

DRAWINGS OF THE ENTIRE ACCESS CONTROL SYSTEM USING FLOOR PLANS PROVIDED BY

THE ENGINEER. SHOP DRAWINGS TO INCLUDE PLANS, SECTIONS, ELEVATIONS, FINAL DEVICE

LOCATIONS, CONDUIT SIZE AND ROUTING AND ALL CONDUCTOR SIZES. TYPICAL RISERS AND

COPYING AND SUBMITTING THE CONTRACT DOCUMENTS WILL NOT BE ACCEPTED.

REFER TO EY SHEETS FOR QUANTITIES AND LOCATIONS OF DEVICES.

PROVIDE DETICATED RUN OF WINDY CITY #4461030 (YELLOW BANANA CABLE) TO NEW EACH DOOR.

BATT BATT

TYPICAL DOOR RELESE BUTTON

TYPICAL DURESS / LOCKDOWN BUTTON

RECONNECT TO EXISTING WIRING THAT IS IN

PLACE. CONFIRM EXISTING WIRING IS

COMPATIBLE WITH THE NEW ACCESS CONTROL

SYSTEM PRIOR TO THE BID.

D

S

CR

TYPICAL INTERIOR ACCESS CONTROL DOOR

ELECTRONIC DOOR STRIKE

CARD READER

120 POWER (PLUG IN TO EXISTING RECEPTACLES)

PROVIDE ALL REQUIRED HARDWARE,

DOOR CONTROLLERS, SOFTWARE,

POWER SUPPLIES AND BATTERIES AS

NECESSARY TO CONNECT ALL NEW

WIRED ACCESS CONTROLS DOORS AS

SHOWN.

ACCESS CONTROL PANEL TO POWER

ALL ELECTRONIC OR ELECTRIFIED

HARDWARE AT ACCESS CONTROLLED

DOOR. PROVIDE PANELS IN QUANTITY

AS NECESSARY FOR A COMPLETE AND

OPERATIONAL SYSTEM.

ACCESS CONTROL ROUGH-IN GENERAL NOTES:

ACCESS CONTROL COORDINATION REQUIREMENTS:

CODE REFERENCES AND REQUIREMENTS:

2016 NFPA 101 - LIFE SAFETY CODE

· 7.2.1.5.6(5) REQUIRES THAT LOSS OF POWER WILL UNLOCK THE ELECTRICALLY CONTROLLED

DOOR HARDWARE.

· 7.2.1.6.2.(4) REQUIRES THAT ACTIVATION OF THE BUILDING FIRE ALARM SYSTEM UNLOCK ALL

DOORS LOCATED IN THE PATH OF EGRESS.

2016 NFPA 80 - FIRE DOORS AND OTHER OPENING PROTECTIVE

· 6.1.3.4 REQUIRES THAT POWER OPERATED FIRE DOORS HAVE A RELEASING DEVICE TO

AUTOMATICALLY RELEASE POWER UPON FIRE ALARM.

· 6.4.4.3.3 REQUIRES THAT FIRE RATED DOORS BE POSITIVELY LATCHED TO MAINTAIN THE FIRE

RATING, ALL ELECTRIC STRIKES USED IN FIRE RATED DOORS MUST BE FAIL SECURE.

2012 IBC - INTERNATIONAL BUILDING CODE

· 1010.1.9.8 REQUIRES ELECTRO MAGNETICALLY LOCKED DOORS HAVE A SENSOR RELEASE

SWITCH EITHER AUTOMATIC OR BY A READILY ACCESSIBLE WALL MOUNTED PUSHBUTTON TO

RELEASE THE LOCK WITHIN 5' OF THE DOOR.

INTEGRATION WITH FIRE ALARM ALL MAGNETIC LOCKS SHALL BE UNLOCKED DURING A GENERAL FIRE ALARM. THIS ACTION IS NOT REQUIRED IF SYSTEM IS IN ALARM BY MEANS OF A MANUAL PULL STATION.

AUTOMATIC DETECTION DEVICES SUCH AS SMOKE DETECTORS OR SPRINKLER FLOW REQUIRE

UNLOCKING AND THE DOOR MUST REMAIN UNLOCKED UNTIL FIRE ALARM SYSTEM RESET. CONTRACTOR SHALL INCLUDE ALL FIRE ALARM INTERFACE EQUIPMENT SUCH AS ADDRESSABLE CONTROL MODULES OR BY CONTACT CLOSURE SIGNALING TO THE ACCESS CONTROL PANELS AS NECESSARY TO MEET THE

CODE REQUIREMENTS. ALL DOORS IN STAIRWELLS MUST ALLOW FOR RE-ENTRY.

***TO ENSURE A COMPLETE AND OPERATING ACCESS CONTROL SYSTEM AND TO ELIMINATE DELAYS, INSUFFICIENT OR UNNECESSARY WORK BY ALL OF THE ENTITIES INVOLVED, THE FOLLOWING STEPS SHALL BE COMPLETED. THE FAILURE TO DO SO RESULTING IN ADDED COSTS AND LOST TIME WILL BE BORN SOLELY BY THE CONTRACTOR. NO ADDITIONAL PAYMENTS WILL BE MADE BY THE OWNER TO

COVER WORK DESCRIBED BELOW.***

DURING THE BIDDING PROCESS:

1. THE ELECTRICAL CONTRACTOR SHALL REVIEW THE FLOOR PLAN DRAWINGS AND DETAILS ON

THIS SHEET. THE FLOOR PLANS WILL INDICATE WHICH DOORS HAVE ACCESS CONTROL

EQUIPMENT REQUIRING ROUGH-IN. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF

THE THE ELECTRICAL ENGINEER FOR CLARIFICATION.

POST-BID, DURING THE SUBMITTAL PROCESS:

1. MEET WITH THE ACCESS CONTROL VENDOR TO REVIEW ALL FINAL INTEGRATION AND ROUGH-IN

REQUIREMENTS. ONLY AFTER CONFIRMING THE FINAL DOOR HARDWARE AND ACCESS CONTROL

SYSTEM REQUIREMENTS SHALL ANY ROUGH-IN WORK BEGIN.

1. THE DOOR DETAILS SHOWN ARE GENERAL ROUGH-IN DETAILS AND NOT ALL DEVICES SHOWN MAY BE

PRESENT FOR EACH DOOR.

2. ALL CONDUIT SHALL BE CONCEALED UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS.

3. THE DOOR ROUGH-IN INFORMATION SHOWN ON THESE DRAWINGS ARE SCHEMATIC IN NATURE AND

CANNOT ACCOUNT FOR ALL SPECIFIC VENDOR REQUIREMENTS, OR ACTUAL DOOR HARDWARE

PROVIDED. COORDINATE SPECIFIC LOCATIONS WITH SECURITY CONTRACTOR PRIOR TO ROUGH-IN.

CONTRACTOR IS RESPONSIBLE FOR A COMPLETE CONDUIT RACEWAY SYSTEM AT THE DOOR AND

BACK TO LOCAL ACCESS CONTROL PANEL.

4. PROVIDE CONDUIT AND DEVICE BACK BOX ROUGH-IN AT ALL CARD READER DOOR LOCATIONS.

CONDUIT SHALL BE 3/4" UNLESS OTHERWISE NOTED AND ALL BOXES SHALL BE 4 SQUARE WITH A SINGLE GANG MUD RING FOR DEVICES OR JUST A SINGLE GANG BOX IF INSTALLED AT THE DOOR

FRAME.

5. ALL CONDUITS ARE TO BE RUN CONTINUOUS TO THE DOOR ACCESS CONTROL PANEL.

6. IF DOOR IS TO BE EQUIPPED WITH AUTOMATIC DOOR OPERATOR, THOSE ROUGH-IN PROVISIONS

SHALL BE IN ADDITION TO THOSE REQUIREMENTS. AUTOMATIC DOOR OPERATORS SHALL HAVE

COMPLETE RUN FROM ITS CONTROL PANEL TO THE DOOR ACCESS CONTROL PANEL AND INCLUDE

120V POWER.

7. FOR DOUBLE DOORS, DUPLICATE THE ROUGH-IN.

SCALE:1 TYPICAL ACCESS CONTROL PANEL RISER DIAGRAM (EXISTING DOOR)

NONE

S

CR

RECONNECT TO EXISTING WIRING THAT IS IN PLACE.

CONFIRM EXISTING WIRING IS COMPATIBLE WITH THE

NEW ACCESS CONTROL SYSTEM PRIOR TO THE BID.

TYPICAL EXTERIOR ACCESS CONTROL DOOR

ELECTRONIC DOOR STRIKE

CARD READER

DOOR POSITION SWITCHD

S

D

ELECTRONIC DOOR STRIKE ADAMS RITE 7740-630 OR 9600-630

DOOR POSITION SWITCH INTERLOGIX 1076D

BATT BATT

TYPICAL DOOR RELESE BUTTON

TYPICAL DURESS / LOCKDOWN BUTTON

3/4" C WITH 4 #18 AWG - BLACK JACKET

D

S

CR

1" CONDUIT WITH WINDY CITY #4461030 (YELLOW BANANA CABLE)

TYPICAL NEW INTERIOR ACCESS CONTROL DOOR

ELECTRONIC DOOR STRIKE

CARD READER

PROVIDE ALL REQUIRED HARDWARE,

DOOR CONTROLLERS, SOFTWARE,

POWER SUPPLIES AND BATTERIES AS

NECESSARY TO CONNECT ALL NEW

WIRED ACCESS CONTROLS DOORS AS

SHOWN.

ACCESS CONTROL PANEL TO POWER

ALL ELECTRONIC OR ELECTRIFIED

HARDWARE AT ACCESS CONTROLLED

DOOR. PROVIDE PANELS IN QUANTITY

AS NECESSARY FOR A COMPLETE AND

OPERATIONAL SYSTEM.

SCALE:2 TYPICAL ACCESS CONTROL PANEL RISER DIAGRAM (NEW DOOR)

NONE

S

CR

TYPICAL NEW EXTERIOR ACCESS CONTROL DOOR

ELECTRONIC DOOR STRIKE

CARD READER

DOOR POSITION SWITCHD

NEW

ACCESS

CONTROL

SYSTEM

PANEL

'ACC'

NEW

ACCESS

CONTROL

SYSTEM

PANEL

'ACC'

120 POWER (PLUG IN TO EXISTING RECEPTACLES)

NETWORK CONNECTIONNETWORK CONNECTION

TO ADDITIONAL 'ACC' PANELS

IN THE SAME ROOM

1" CONDUIT WITH WINDY CITY #4461030 (YELLOW BANANA CABLE)

AVIGILON 12/14V 8-DOOR SMART HUB

AVIGILON UNITY ACCESS 7 (ENTERPRISE) MOUNT SERVER IN EXISTING DATA RACK

LOCATED IN IT S1009 IN LOCATION AS

DIRECTED BY THE OWNER. SERVER SIZE IS

1RU. BUILDING TO BE USED AS AN ACCESS

CONTROL HUB IN THE FUTURE, PROVIDE

ALL NECESSARY NETWORK CONNECTIONS

AND CAPACITY AS NECESSARY.

CREDENTIAL CARDS HID ISOPROX II - 48BIT CORPORATE CONFIRM CARD TYPE WITH OWNER PRIOR

TO ORDERING. PROVIDE 500 CARDS.

COLOR TO MATCH DOOR FRAME. CONFIRM

PRIOR TO ORDERING.

KEYED NOTES:

1. CAT 6A CABLE TO EXISTING NETWORK RACK IN IT S1009. CONFIRM JACKET COLOR WITH OWNER

PRIOR TO ORDERING CABLE. CONFIRM TERMINATION LOCATION WITH THE OWNER PRIOR TO

ANY ROUGH-IN.

2. CAT 6A CABLE TO NEXT ACCESS CONTROL PANEL WERE MULTIPLE PANELS ARE IN THE SAME

ROOM. CONFIRM JACKET COLOR WITH THE OWNER PRIOR TO ORDERING CABLE.

TO ADDITIONAL 'ACC' PANELS

IN THE SAME ROOM

DOOR POSITION

SWITCH

ELECTRIC STRIKE

3/4" C.

1" CONDUIT TO ACCESSIBLE CEILING

SPACE OR LOCAL COMMUNICATIONS

ROOM. REFER TO SPECIFICATIONS.

3/4" C.

SCALE:3 TYPICAL ACCESS CONTROL DOOR ROUGH-IN DETAIL

NONE

6"X6"X4" SQ JUNCTION BOX. MOUNT

JUNCTION BOX ABOVE DOOR IN THE

CEILING SPACE OF THE SECURE SIDE

ACCESS CONTROL

USER DEVICE

(UNSECURE SIDE)

NEW ACCESS CONTROL PANEL

ENCLOSURE MUST BE SURFACE

MOUNTED.

NEW ACCESS CONTROL PANEL

ENCLOSURE MUST BE SURFACE

MOUNTED.

RECONNECT TO EXISTING WIRING THAT IS IN PLACE.

CONFIRM EXISTING WIRING IS COMPATIBLE WITH THE

NEW ACCESS CONTROL SYSTEM PRIOR TO THE BID.

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

REVIEWED FOR

CODE COMPLIANCE

THOMAS PETERSON

07/02/2026 http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com

WH

H1057

CPS FILE

H1057

CPS FILE

H1055

ATTY FILE

H1055

ATTY FILE

H1069

SS WORK

H1069

SS WORK

H1066

SS WORK

H1066

SS WORK

H1065

SS WORK

H1065

SS WORK

H1064

SS WORK

H1064

SS WORK

H1063

SS WORK

H1063

SS WORK

H1062

SS WORK

H1062

SS WORK

H1061

SS WORK

H1061

SS WORKH1060

SS WORK

H1060

SS WORK

H1059

SS WORK

H1059

SS WORK

H1058

SS WORK

H1058

SS WORK

H1067

STAIR 2

H1067

STAIR 2

S1015

ELEC

S1015

ELEC

H1073

SS WORK

H1073

SS WORK

H1074

HS SUPR

H1074

HS SUPR

H1075

HS SUPR

H1075

HS SUPR

H1076

SS WORK

H1076

SS WORK

H1077

SS WORK

H1077

SS WORK

H1078

SS WORK

H1078

SS WORK

H1079

SS WORK

H1079

SS WORK

H1080

SS WORK

H1080

SS WORK

H1081

SS WORK

H1081

SS WORK

H1082

SS WORK

H1082

SS WORK

H1083

SS WORK

H1083

SS WORK

H1084

CAR SEAT

H1084

CAR SEAT

H1043

CSM

H1043

CSM

H1042

COMP SUPP

H1042

COMP SUPP

H1041

TRAINER

H1041

TRAINER

H1040

TRAINER

H1040

TRAINER

H1037

LIB RES

H1035

M HEALTH

H1038

TRN SUPP

H1038

TRN SUPP

H1032

SS WORK

H1032

SS WORK

H1031

MHS SUPR

H1031

MHS SUPR

H1030

SS WORK

H1030

SS WORK

H1029

MED CONF

H1029

MED CONF

H1028

BRK

H1028

BRK

H1039

TRAINING

H1039

TRAINING

H1051

OPEN OFF

H1051

OPEN OFF

H1047

ATTY GEN

H1047

ATTY GEN

H1048

ATTY GEN

H1048

ATTY GEN

H1049

ATTY GEN

H1049

ATTY GEN

H1050

ATTY GEN

H1050

ATTY GEN

H1052

ATTY GEN

H1052

ATTY GEN

H1053

ATTY GEN

H1053

ATTY GEN

H1054

ATTY GEN

H1054

ATTY GEN

H1056

HS SUPR

H1056

HS SUPR

H1070

SS WORK

H1070

SS WORK

H1071

SS WORK

H1071

SS WORK

H1072

SS WORK

H1072

SS WORK

H1068

IDF\

H1068

IDF\

H1021

OBS

H1021

OBS

H1023

OBS

H1023

OBS

H1025

ELEV MACH

H1025

ELEV MACH

H1024

STOR

H1024

STOR

H1022

VISIT

H1022

VISIT

H1020

VISIT

H1020

VISIT

H1019

VISIT

H1019

VISIT

H1017

VISIT

H1017

VISIT

H1016

CLST

H1016

CLST

H1015

VISIT

H1015

VISIT

H1013

VISIT

H1013

VISIT

S1017

DFCM MAINT

S1017

DFCM MAINT

S1018

IT OFF

S1018

IT OFF

S1005

MEN

S1005

MEN

S1004

WOMEN

S1004

WOMEN

S1010

SM CONF

S1010

SM CONFH1004

C&F TEAM

H1004

C&F TEAM

H1003

C&F TEAM

H1003

C&F TEAM

H1510

HALL

H1510

HALL

H1505

HALL

H1505

HALL

H1503

HALL

H1503

HALL

H1502

HALL

H1502

HALL

H1501

HALL

H1501

HALL

H1026

FILE/WORK

H1026

FILE/WORK H1002

RECP

H1002

RECP

H1001

WAIT

H1001

WAIT

H1007

INT/INTV

H1007

INT/INTVH1008

C&F TEAM

H1008

C&F TEAM

H1005

INT/INTV

H1005

INT/INTV

S1512

ENTRY

S1512

ENTRY

S1511

HALL

S1511

HALL

S1001

LG CONF

S1001

LG CONF

S1011

SM CONF

S1011

SM CONF

S1009

IT

S1009

IT

S1002

MED CONF

S1002

MED CONF R1003

INT/CONF

R1003

INT/CONF

S1513

ENTRY

S1513

ENTRY

R1001

WAIT

R1001

WAIT

S1019

BLDG STOR

S1019

BLDG STOR

S1008

AB STOR

S1008

AB STOR

S1003

BOILER

S1003

BOILER

S1021

MECH

S1021

MECH

R1008

COUNS

R1008

COUNS

R1009

TEACH

COUNS

R1009

TEACH

COUNS

R1010

COUNS

SUPR

R1010

COUNS

SUPR

R1515

HALL

R1515

HALL

R1011

EMP COUNS

R1011

EMP COUNS

R1016

OPEN OFF

R1016

OPEN OFF

R1012

RISER

FIRE

R1012

RISER

FIRE

R1014

VR SUPR

R1014

VR SUPR

R1015

RHB COUNS

R1015

RHB COUNS

R1019

RHB COUNS

R1019

RHB COUNS

R1517

HALL

R1517

HALL

R1018

MAIL/WORK

R1018

MAIL/WORK

R1017

LOUNGE

R1017

LOUNGE

R1004

DRIVERS

R1004

DRIVERS

H1026A

ELEC

H1026A

ELEC

H1012

C UNI REST

H1012

C UNI REST

H1014

UNI REST

H1014

UNI REST

S1514

HALL

S1514

HALL

R1002

RECP

R1002

RECP

S1020

UNI REST

S1020

UNI REST

S1006

WOMEN

S1006

WOMEN

S1007

MEN

S1007

MEN

R1516

HALL

R1516

HALL

R1519

HALL

R1519

HALL

R1021

FILE

R1021

FILE

S1013

BRK

S1013

BRK

R1026

STAIR 3

R1026

STAIR 3

R1022

JAN

R1022

JAN

R1025

RHB COUNS

R1025

RHB COUNS

R1020

RHB COUNS

R1020

RHB COUNS

R1023

RHB COUNS

R1023

RHB COUNS

R1024

RHB COUNS

R1024

RHB COUNS

R1028

RHB COUNS

R1028

RHB COUNS

R1029

RHB COUNS

R1029

RHB COUNS

R1520

HALL

R1520

HALL

R1030

RHB COUNS

R1030

RHB COUNS

R1031

TEST SUPP

R1031

TEST SUPP

R1036

VE SEC

R1036

VE SEC

R1035

VOC EVAL

R1035

VOC EVAL

R1034

VOC EVAL

R1034

VOC EVAL

R1037

VE TEST

R1037

VE TEST

D1001

WAIT

D1001

WAIT

S1014

GRND STOR

S1014

GRND STOR

D1003

RECP/CHART

D1003

RECP/CHART

D1523

HALL

D1523

HALL

D1004

CL OPER

D1004

CL OPER

D1002

REST

UNI

D1002

REST

UNI

D1006

OPER

D1006

OPER

D1008

OPER

D1008

OPER

D1009

OPER

D1009

OPER

D1010

OPER

D1010

OPER

D1012

PAN

D1012

PAN

D1011

BRK/CONF

D1011

BRK/CONF

D1522

HALL

D1522

HALL

D1010A

CLST

D1010A

CLST

D1013

OFF

D1013

OFF

D1014

UTIL

D1014

UTIL

D1521

HALL

D1521

HALL

D1007

STER/LAB

D1007

STER/LAB

D1016

UNI REST

D1016

UNI REST

D1015

LNDRY

D1015

LNDRY

R1518

HALL

R1518

HALL

R1027

RHB COUNS

R1027

RHB COUNS

R1032

Q TEST

R1032

Q TEST

R1033

Q TEST

R1033

Q TEST

H1508

HALL

H1508

HALL

S1010A

CLST

S1010A

CLST

H1507

HALL

H1507

HALL

H1504

HALL

H1504

HALL

R1012A

STOR

R1012A

STOR R1013

VR DIR

R1013

VR DIR

S1022

ELEC

S1022

ELEC

H1045

WOMEN

H1045

WOMEN

H1044

JAN

H1044

JAN

H1046

MEN

H1046

MEN

H1009

STAIR 1

H1009

STAIR 1

CR

D S

C R

S S

D S

CR

CRS

CR

S

D

C R

D S

D S

S

C R

CR

S

D DCR

S

S

CR

C R

S D

C R

S

D

C R

D S

C R

DS

CR

S D

C R

S

S

CR

C R

1 2

'ACC8'

'ACC8'

'ACC9'

'ACC9' 'ACC9'

'ACC9'

'ACC6'

'ACC7'

'ACC6'

'ACC7'

'ACC8'

'ACC2'

'ACC1'

'ACC2'

'ACC4'

'ACC4'

'ACC1'

'ACC5'

'ACC5'

'ACC8'

'ACC3'

'ACC4'

'ACC2'

'ACC1'

'ACC5'

'ACC3'

'ACC3'

(TYP)

(TYP)

(TYP)

(TYP)

NO. DATE REVISIONS

DFCM PROJECT NO:

A

1 2 3 4 5

1 2 3 4 5

27082310

CHECKED BY: SDK/DPW

DESIGNED BY: SDK

DRAWN BY: JDB

ENVISION PROJECT NO: 2026.107.00

DATE:

ISSUE:

JUNE 26, 2026

PERMIT SET

B

C

D

A

B

C

D

DF

CM

A

CA

DE

MY

S

QU

AR

E

AC

CE

SS

C

ON

TR

OL

S

YS

TE

M

UP

GR

AD

E

0 E

AS

T

TH

S

TR

EE

T

OG

DE

N, U

TA

H

6 7

E

F

E

F

6 7

Fil e N am e:

V:

\26

\20

-1

.00

DC

FS

Ac ad em y S qu ar e -

A cc es s C on tro ls\

_D wg s\E D1

.dw g L as t P lot ted : 2

6/0

6/2 6 @

5:

:07 P

M By

: S

CO

TT

.K

IN

GE

RY

240 E. MORRIS AVE, SUITE 200

SALT LAKE CITY, UT 84115

P (801) 534-1130 www.envisioneng.com

ENV: 2026-107.00

AGENCY APPROVAL STAMP

KEYED NOTES:

1. DISCONNECT, REMOVE AND RETURN EXISTING CARD READER TO THE OWNER. EXISTING WIRING

TO REMAIN IN PLACE FOR REUSE, UNLESS OTHERWISE DIRECTED BY THE ACCESS CONTROL

SYSTEM SUPPLIER. CONFIRM EXISTING WIRING IS COMPATIBLE WITH THE NEW ACCESS

CONTROL SYSTEM PRIOR TO THE BID.

2. DISCONNECT, REMOVE AND RETURN OR DISPOSE OF EXISTING ELECTRONIC STRIKE, CONFIRM WITH OWNER PRIOR TO THE START OF THE DEMOLITION. EXISTING WIRING TO REMAIN IN PLACE

FOR REUSE, UNLESS OTHERWISE DIRECTED BY THE ACCESS CONTROL SYSTEM SUPPLIER.

CONFIRM EXISTING WIRING IS COMPATIBLE WITH THE NEW ACCESS CONTROL SYSTEM PRIOR

TO THE BID.

3. DISCONNECT, REMOVE AND DISPOSE OF EXISTING DOOR POSITION SWITCH. EXISTING WIRING

TO REMAIN IN PLACE FOR REUSE, UNLESS OTHERWISE DIRECTED BY THE ACCESS CONTROL

SYSTEM SUPPLIER. CONFIRM EXISTING WIRING IS COMPATIBLE WITH THE NEW ACCESS

CONTROL SYSTEM PRIOR TO THE BID.

4. DISCONNECT, REMOVE AND DISPOSE OF EXISTING DOOR RELEASE BUTTON. EXISTING WIRING

TO REMAIN IN PLACE FOR REUSE, UNLESS OTHERWISE DIRECTED BY THE ACCESS CONTROL

SYSTEM SUPPLIER. CONFIRM EXISTING WIRING IS COMPATIBLE WITH THE NEW ACCESS

CONTROL SYSTEM PRIOR TO THE BID.

5. DISCONNECT, REMOVE AND RETURN EXISTING ACCESS CONTROL PANEL TO THE OWNER.

EXISTING ACCESS CONTROL WIRING AND RECEPTACLE TO REMAIN IN PLACE FOR REUSE,

UNLESS OTHERWISE DIRECTED BY THE ACCESS CONTROL SYSTEM SUPPLIER. CONFIRM

EXISTING WIRING IS COMPATIBLE WITH THE NEW ACCESS CONTROL SYSTEM PRIOR TO THE BID.

6. DISCONNECT, REMOVE AND RETURN EXISTING POWER SUPPLY TO THE OWNER. EXISTING

BRANCH CIRCUIT TO REMAIN IN PLACE FOR REUSE. CONTRACTOR TO CONFIRM BRANCH

CIRCUIT USED IN THE FIELD. NOTE BRANCH CIRCUIT ON REDLINE AS-BUILT DRAWINGS.

GENERAL DEMOLITION NOTES:

1. UNLESS SPECIFICALLY NOTED OTHERWISE, REMOVE ALL ELECTRICAL ITEMS SHOWN IN DARK AND DASHED LINES. LIGHT AND SOLID ITEMS ARE TO REMAIN. DEMOLITION ITEMS ARE SHOWN

TO GIVE A BASIC DESCRIPTION OF THE EXTENT OF DEMOLITION WORK, BUT MAY NOT BE

INCLUSIVE. PROVIDE DEMOLITION WORK IN ACCORDANCE WITH THE FOLLOWING

REQUIREMENTS:

A. DISCONNECT AND REMOVE ANY / ALL FIXTURES, DEVICES, EQUIPMENT, ETC. REQUIRED

FOR PROPER COMPLETION OF THE WORK WHETHER SHOWN OR NOT.

B. RELOCATE, REWIRE, AND/OR RECONNECT ANY / ALL FIXTURES, DEVICES, EQUIPMENT,

ETC. THAT FOR ANY REASON OBSTRUCTS CONSTRUCTION.

C. LEAVE ALL EXISTING FIXTURES, DEVICE, EQUIPMENT, ETC. IN PORTIONS OF THE BUILDING

NOT BEING REMODELED, IN WORKING CONDITION. RESTORE ALL INTERRUPTED BRANCH

CIRCUITS, FEEDERS, ETC.

D. REMOVE AND DISPOSE OF ALL RACEWAYS, CONDUCTORS, BOXES, DEVICES, EQUIPMENT,

ETC. THAT ARE NOT TO BE REUSED. TERMINATE AT ACCESSIBLE JUNCTION BOX BY

PROVIDING PROPER KNOCK-OUT CLOSURE, TAPE CONDUCTORS, LABEL AS ''SPARE'' WITH

CIRCUIT NO., ZONE NO., OR OTHER CHARACTERISTIC IDENTIFYING SOURCE.

E. EXISTING RACEWAYS MAY BE REUSED, IF IN PLACE, WHERE POSSIBLE, AND WHERE IN

COMPLIANCE WITH THE SPECIFICATIONS AND THE INTENT OF THE CONTRACT

DOCUMENTS. UPGRADE AND OR PROVIDE NEW CONDUIT SUPPORTS WHERE NECESSARY

FOR ALL RACEWAYS BEFORE REUSE.

F. CONCEAL ALL RACEWAY AND WIRING IN EXISTING WALLS, CEILING, FLOORS, ETC. THE USE

OF WIREMOLD IS PERMITTED ONLY WHERE SPECIFICALLY NOTED ON DRAWING.

G. DO NOT PENETRATE STRUCTURAL ELEMENTS OF FLOORS, WALLS, CEILINGS, ROOFS, ETC.

H. COORDINATE WITH OWNER WHAT EQUIPMENT SHOULD BE DISPOSED OF AND WHAT

EQUIPMENT IS TO BE RETURNED TO OWNER.

I. FIRE ALARM SYSTEM MUST REMAIN OPERATIONAL DURING ALL PHASES OF

CONSTRUCTION.

2. ANY EXISTING CONDUITS, BOXES, ETC THAT ARE LOCATED IN THE AFFECTED CONSTRUCTION

AREA SHALL BE RELOCATED OR RE-ROUTED AS NECESSARY.

3. BRANCH CIRCUIT, IF SHOWN WERE TAKEN FROM EXISTING RECORD DRAWINGS AND PANEL

SCHEDULES AND MAY NOT BE ACCURATE. CONTRACTOR SHALL TRACE OUT ALL CIRCUITS THAT

WILL BE AFFECTED BY THIS PROJECT PRIOR TO ANY DEMOLITION.

4. THIS AND ANY OTHER DEMOLITION DRAWINGS ARE NOT INTENDED TO BE ALL-INCLUSIVE, NOR

TO DEFINE THE SCOPE OF ALL DEMOLITION WORK REQUIRED FOR THIS PROJECT. DEMOLITION

DRAWINGS ARE SHOWN ONLY TO AID THE CONTRACTOR IN PREPARING THE BID AND

PERFORMING THE WORK. CONTRACTOR SHALL EXAMINE ALL CONTRACT DOCUMENTS AND

VISIT THE SITE DURING BIDDING TO DETERMINE THE TOTAL EXTENT AND SCOPE OF THE

DEMOLITION PORTION OF THIS WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL

DEMOLITION WORK REQUIRED TO CARRY OUT THE WORK AS SHOWN IN THE CONTRACT

DOCUMENTS.

FIRST FLOOR DEMOLITION SYSTEM PLAN

0 5'-6" 11' 22'

SCALE: 3/32" = 1'-0"

ED101

FIRST FLOOR

DEMOLITION

SYSTEM PLAN

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

REVIEWED FOR

CODE COMPLIANCE

THOMAS PETERSON

07/02/2026 http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com

WH

H1057

CPS FILE

H1055

ATTY FILE

H1069

SS WORK

H1066

SS WORK

H1065

SS WORK

H1064

SS WORK

H1063

SS WORK

H1062

SS WORK

H1061

SS WORKH1060

SS WORK

H1059

SS WORK

H1058

SS WORK

H1067

STAIR 2

S1015

ELEC

H1073

SS WORK

H1074

HS SUPR

H1075

HS SUPR

H1076

SS WORK

H1077

SS WORK

H1078

SS WORK

H1079

SS WORK

H1080

SS WORK

H1081

SS WORK

H1082

SS WORK

H1083

SS WORK

H1084

CAR SEAT

H1043

CSM

H1042

COMP SUPP

H1041

TRAINER

H1040

TRAINER

H1038

TRN SUPP

H1032

SS WORK

H1031

MHS SUPR

H1030

SS WORK

H1029

MED CONF

H1028

BRK

H1039

TRAINING

H1051

OPEN OFF

H1047

ATTY GEN

H1048

ATTY GEN

H1049

ATTY GEN

H1050

ATTY GEN

H1052

ATTY GEN

H1053

ATTY GEN

H1054

ATTY GEN

H1056

HS SUPR

H1070

SS WORK

H1071

SS WORK

H1072

SS WORK

H1068

IDF\

H1021

OBS

H1023

OBS

H1025

ELEV MACH

H1024

STOR

H1022

VISIT

H1020

VISIT

H1019

VISIT

H1017

VISIT

H1016

CLST

H1015

VISIT

H1013

VISIT

S1017

DFCM MAINT

S1018

IT OFF

S1005

MEN

S1004

WOMEN

S1010

SM CONFH1004

C&F TEAM

H1003

C&F TEAM

H1510

HALL

H1505

HALL

H1503

HALL

H1502

HALL

H1501

HALL

H1026

FILE/WORK H1002

RECP

H1001

WAIT

H1007

INT/INTVH1008

C&F TEAM

H1005

INT/INTV

S1512

ENTRY

S1511

HALL

S1001

LG CONF

S1011

SM CONF

S1009

IT

S1002

MED CONF R1003

INT/CONF

S1513

ENTRY

R1001

WAIT

S1019

BLDG STOR

S1008

AB STOR

S1003

BOILER

S1021

MECH

R1008

COUNS

R1009

TEACH

COUNS

R1010

COUNS

SUPR

R1515

HALL

R1011

EMP COUNS

R1016

OPEN OFF

R1012

RISER

FIRE

R1014

VR SUPR

R1015

RHB COUNS

R1019

RHB COUNS

R1517

HALL

R1018

MAIL/WORK

R1017

LOUNGE

R1004

DRIVERS

H1026A

ELEC

H1012

C UNI REST

H1014

UNI REST

S1514

HALL

R1002

RECP

S1020

UNI REST

S1006

WOMEN

S1007

MEN

R1516

HALL

R1519

HALL

R1021

FILE

S1013

BRK

R1026

STAIR 3

R1022

JAN

R1025

RHB COUNS

R1020

RHB COUNS

R1023

RHB COUNS

R1024

RHB COUNS

R1028

RHB COUNS

R1029

RHB COUNS

R1520

HALL

R1030

RHB COUNS

R1031

TEST SUPP

R1036

VE SEC

R1035

VOC EVAL

R1034

VOC EVAL

R1037

VE TEST

D1001

WAIT

S1014

GRND STOR

D1003

RECP/CHART

D1523

HALL

D1004

CL OPER

D1002

REST

UNI

D1006

OPER

D1008

OPER

D1009

OPER

D1010

OPER

D1012

PAN

D1011

BRK/CONF

D1522

HALL

D1010A

CLST

D1013

OFF

D1014

UTIL

D1521

HALL

D1007

STER/LAB

D1016

UNI REST

D1015

LNDRY

R1518

HALL

R1027

RHB COUNS

R1032

Q TEST

R1033

Q TEST

H1508

HALL

S1010A

CLST

H1507

HALL

H1504

HALL

R1012A

STOR R1013

VR DIR

S1022

ELEC

H1045

WOMEN

H1044

JAN

H1046

MEN

H1009

STAIR 1

CR

D S

C R

S S

D S

CR

CR

S

CR

S

D

C R

D S

D S

DS

C R

CR

'ACC1'

S

D DCR

S

S

CR

C R

'ACC3'

S D

C R

S

D

C R

'ACC5'

D S

C R

DS

CR

S D

C R

S

S

CR

C R

C R

C R

S

'ACC4'

C R

S S D D D

S D

S

C R

'ACC2'

ADD

ALTERNATE

#1

ADD

ALTERNATE

#1

'ACC5' 'ACC5'

'ACC4'

'ACC4'

'ACC4' 'ACC4'

'ACC4'

'ACC4'

'ACC2' 'ACC2'

'ACC2'

'ACC1'

'ACC1'

'ACC1'

'ACC3'

'ACC1'

'ACC1'

'ACC1'

'ACC4'

'ACC3'

'ACC2'

9 5

D

'ACC2'

D

D

(TYP)

NO. DATE REVISIONS

DFCM PROJECT NO:

A

1 2 3 4 5

1 2 3 4 5

27082310

CHECKED BY: SDK/DPW

DESIGNED BY: SDK

DRAWN BY: JDB

ENVISION PROJECT NO: 2026.107.00

DATE:

ISSUE:

JUNE 26, 2026

PERMIT SET

B

C

D

A

B

C

D

DF

CM

A

CA

DE

MY

S

QU

AR

E

AC

CE

SS

C

ON

TR

OL

S

YS

TE

M

UP

GR

AD

E

0 E

AS

T

TH

S

TR

EE

T

OG

DE

N, U

TA

H

6 7

E

F

E

F

6 7

Fil e N am e:

V:

\26

\20

-1

.00

DC

FS

Ac ad em y S qu ar e -

A cc es s C on tro ls\

_D wg s\E Y1

.dw g L as t P lot ted : 2

6/0

6/2 6 @

5:

:27 P

M By

: S

CO

TT

.K

IN

GE

RY

240 E. MORRIS AVE, SUITE 200

SALT LAKE CITY, UT 84115

P (801) 534-1130 www.envisioneng.com

ENV: 2026-107.00

AGENCY APPROVAL STAMP

KEYED NOTES:

1. PROVIDE NEW ACCESS CONTROL CARD READER, ELECTRONIC STRIKE AND DOOR POSITION

SWITCH AS SHOWN. RECONNECT TO EXISTING WIRING THAT IS WAS IN PLACE PRIOR TO THE

DEMOLITION. CONFIRM EXISTING WIRING IS COMPATIBLE WITH THE NEW ACCESS CONTROL

SYSTEM PRIOR TO THE BID. PROVIDE NEW WIRING AS NECESSARY FOR A COMPLETE AND

OPERATIONAL SYSTEM.

2. PROVIDE NEW ACCESS CONTROL CARD READER AND ELECTRONIC STRIKE SHOWN. RECONNECT

TO EXISTING WIRING THAT IS WAS IN PLACE PRIOR TO THE DEMOLITION. CONFIRM EXISTING WIRING IS COMPATIBLE WITH THE NEW ACCESS CONTROL SYSTEM PRIOR TO THE BID. PROVIDE

NEW WIRING AS NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM.

3. PROVIDE MULLION MOUNTED CARD READER.

4. PROVIDE NEW DOOR POSITION SWITCH. PROVIDE NEW WIRING BACK TO THE ACCESS CONTROL

PANEL. UTILIZE EXISTING ACCESS CONTROL RACEWAY.

5. PROVIDE NEW MOMENTARY CONTACT DOOR SHOWN. MOUNT BELOW COUNTER TOP IN THE

SAME LOCATION AS THE DEMOLISHED BUTTONS. CONFIRM EXISTING WIRING IS COMPATIBLE

WITH THE NEW ACCESS CONTROL SYSTEM PRIOR TO THE BID. PROVIDE NEW WIRING AS

NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM.

6. NEW ACCESS CONTROL SYSTEM PANEL LOCATION. MODIFY EXISTING DOOR CONDUITS, WIRING

AND POWER LOCATIONS AS NECESSARY FOR NEW PANEL LOCATIONS AND QUANTITIES.

7. NEW EXTERIOR ACCESS CONTROL DOOR. PROVIDE NEW CARD READER, ELECTRONIC STRIKE(S)

AND DOOR POSITION SWITCH(ES). EXTEND A 1'' CONDUIT WITH WIRING TO THE ACCESS

CONTROL SYSTEM PANEL AS CALLED OUT.

8. NEW INTERIOR ACCESS CONTROL DOOR. PROVIDE NEW CARD READER AND ELECTRONIC

STRIKE. EXTEND A 1'' CONDUIT WITH WIRING TO THE ACCESS CONTROL SYSTEM PANEL AS

CALLED OUT.

9. PROVIDE NEW LOCK DOWN BUTTON TO CONTROL DOOR AS SHOWN. MOUNT BELOW COUNTER

TOP IN THE SAME LOCATION AS THE DEMOLITION BUTTONS. RECONNECT TO EXISTING WIRING

THAT WAS IN PLACE PRIOR TO THE DEMOLITION. CONFIRM EXISTING WIRING IS COMPATIBLE

WITH THE NEW ACCESS CONTROL SYSTEM PRIOR TO THE BID. PROVIDE NEW WIRING AS

NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM.

10. PROVIDE NEW LOCK DOWN BUTTON TO CONTROL DOOR AS SHOWN. MOUNT BELOW COUNTER

TOP IN THE SAME LOCATION AS THE DEMOLITION BUTTONS. EXTEND A 3/4'' CONDUIT WITH

WIRING FROM THE DOOR TO THE BUTTON LOCATION. PROVIDE ALL CONNECTIONS BACK TO THE

ACCESS CONTROL PANEL FOR THE DOOR, NEW WIRING TO BE IN 3/4'' CONDUIT.

11. PROVIDE ALL SOFTWARE AND PROGRAMMING OF COMPUTER WORK STATION IN THIS ROOM TO

HAVE THE ABILITY TO ACCESS THE ACCESS CONTROL SYSTEM AND VIEW ACCESS CONTROL

SYSTEM ACTIVITY.

12. PROVIDE NEW ACCESS CONTROL PANEL (8 DOOR) AT THIS LOCATION.

13. PROVIDE NEW ACCESS CONTROL PANEL (4 DOOR) AT THIS LOCATION.

14. PROVIDE NEW ACCESS CONTROL CARD READER AND ELECTRONIC STRIKE AS SHOWN.

RECONNECT TO EXISTING WIRING THAT IS WAS IN PLACE PRIOR TO THE DEMOLITION. CONFIRM EXISTING WIRING IS COMPATIBLE WITH THE NEW ACCESS CONTROL SYSTEM PRIOR TO THE BID.

PROVIDE NEW WIRING AS NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM.

SYSTEMS GENERAL NOTES:

1. THE CONTRACTOR SHALL WORK CLOSELY WITH THE OWNER TO PROVIDE A COMPLETE AND

WORKING SYSTEM.

2. COORDINATE ALL WALL MOUNTED LOCATIONS WITH EXISTING EQUIPMENT AND WALL MOUNTED

DEVICES.

3. THE DIVISION 28 CONTRACTOR SHALL DETERMINE THE EXACT ROUTING OF ALL CONDUITS IN

THE FIELD. THIS PLAN REPRESENTS A SCHEMATIC REPRESENTATION OF DEVICE LOCATIONS.

4. ALL NEW WIRING SHALL BE RUN IN CONDUIT. SEE DOOR ROUGH-IN DETAILS.

FIRST FLOOR SYSTEM PLAN

EY101

FIRST FLOOR

SYSTEM PLAN

0 5'-6" 11' 22'

SCALE: 3/32" = 1'-0"

BASE BID:

NO ACCESS CONTROL SYSTEM INSTALLATION OR ROUGH-IN FOR

DOORS INDICATED.

ALTERNATE:

PROVIDE ACCESS CONTROL SYSTEM AS SHOWN FOR DOORS

INDICATED. PROVIDE ALL REQUIRED HARDWARE, DEVICES, WIRING

AND ROUGH-IN AS NECESSARY FOR A COMPLETE AND OPERATIONAL

SYSTEM.

ADD ALTERNATE #1.

DIVISION OF FACILITIES

CONSTRUCTION AND

MANAGEMENT

REVIEWED FOR

CODE COMPLIANCE

THOMAS PETERSON

07/02/2026 http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com http://www.envisioneng.com

Sheets and Views
EG001-30X42
OLE1
EG101-30X42
ED101-30X42
EY101-30X42

File details come from the government source that posted it. Updated .