3-1. Specifications.pdf
PDF 246 KB Posted
- Solicitation number
- RFP-221-25
- Issued by
- Boulder County, Colorado
About this file
This is a specifications document issued by Boulder County Procurement for RFP-221-25 regarding commercial laundry equipment and maintenance services for the Joe Pelle Center, a community-based minimum security residential facility in Boulder, Colorado that houses alternative sentencing programs. The vendor is required to provide, install, and maintain 10 commercial washer and dryer pairs (non-coin or card operated) for client use. The vendor must be responsible for site measurement to ensure proper sizing of the equipment and must provide stackable units meeting the specified technical requirements. The vendor is obligated to provide a maintenance service plan with a maximum repair turnaround time of 14 days from the receipt of any repair request, including warranty items.
The specifications outline detailed technical requirements for the washer and dryer units, including capacity specifications (21.5 pounds for washers, 18 pounds for dryers), dimensions, water consumption rates, energy efficiency metrics, available cycles and water temperatures, electrical and gas requirements, and exhaust specifications. The document includes a typical client laundry elevation diagram showing the installation layout with ductwork routing to the roof for the second floor, as well as power and water connections. The vendor must have expertise in commercial laundry equipment sizing, installation, and ongoing maintenance to successfully fulfill the contract requirements for this Boulder County correctional facility.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Boulder County Procurement 1325 Pearl Street
Boulder, CO 80302
Specifications RFP-221-25
Boulder County’s Joe Pelle Center (JPC) is a community-based, minimum security, residential facility that will house all alternative sentencing programs utilized in Boulder County.
The purpose is to provide laundry machines for the use of Joe Pelle Center clients.
Vendor will provide, install, and maintain 10 commercial washer and dryer pairs (not coin or card operated) for use of the clients at the Joe Pelle Center. The vendor will provide pricing for 10 stackable washers and dryers and be responsible for measuring to ensure correct size of washers and dryers is ordered. Washer and Dryer should be installed per specs on next page.
The vendor will provide a maintenance service plan. The vendor shall ensure that warranty items and repairs are completed within 14 days of receiving a repair request.
Example Specs
• Capacity - lb (kg): Washer 21.5 (9.5); Dryer 18 (8.2)
• Overall Width - in (mm) 26.875 (683)
• Overall Depth - in (mm) 27.73 (704)
• Overall Height - in (mm) 78.17 (1986)
• Cylinder Volume cu. ft. (liters): Washer 3.42 (96.8); Dryer 7.0 (198)
• Motor Size - HP (kW) 0.9 (0.67)
• Type Of Gas (Gas Models Only) Factory Equipped Natural
• Water Consumption Per Cycle - g (liter): 13.68 (51.78)
• IWF (Water Factor) - gal/ft³ (liters/liter/cycle): 4.0 (0.53)
• MEFJ2 (Modified Energy Factor) ft³/kWh/cycle (liters/kWh/cycle) ; 2.20 (62.3)
• Available Water Temperatures: Cold, Warm, Hot
• Available Cycles: Washer - Normal, Synthetic, Delicate; Dryer - High, Medium, Low, Delicate, No Heat
• Air Outlet Diameter - in (mm) 4 (102)
• Exhaust Airflow - cfm (liters/sec) 220 (105)
• Electrical Requirements: Electric - 120/208-240/60/1-30 amp; Gas - 120/60/1-15 amp
• Heating Element: Electric - 5350W, 240V; 4750W, 208V; Gas - 25,000 Btu
• Net Weight - lb (kg) 385 (175)
Scroll to the next page for additional information.
14•EXHAUST
DUCT TOROOF,
TYP. FOR2ND
FlOOR.
I , -
I l
I I I I
DRYER,'
I I
DRYE•R
4• DIA. EXHAUST
BRANCH,TYP.
PWR+HOTa
COLDWATER.
TYP.
I I I I
CLIENT
LAUNDRY/
JANrTOR
DRYE'R
I l
I r
WASHER
WASHER
l.,, io
·-· -'i
TYPICAL CLIENT LAUNDRY ELEVATION
FEET
2 J 4 5
·-· -'i.
| 1. Specifications.pdf |
| Specifications RFP-221-25 |
| updated specs.pdf |
| 1. Specifications.pdf |
| TYPICAL CLIENT LAUNDRY ELEVATION |
File details come from the government source that posted it. Updated .