ADDENDA No. 2
August 21, 2025
Thompsontown Municipal Authority
Water Filtration Building
General Construction Contract
Electrical Construction Contract
August 21, 2025
Engineer�s Project 1007.013
The following questions were posted on PennBID and responses are provided herein:
1. Question: 1) What gauge and panel width is required for the roofing panels? 2) What type of snow retention system is required?
Answer: Roofing panels shall standard width, 26-gauge. No snow retention system is required.
2. Question: Spec 085414 calls for the windows to be fiberglass reinforced but drawing A3 note 17
& 18 call for aluminum framed windows. Which is correct? If aluminum is correct please update the spec to reflect this.
Answer: The windows shall be aluminum framed windows. A revised section 08 54 14 spec will be included.
3. Question: Is the wall framing lumber & Drywall required to be fire rated?
Answer: Framing and drywall are to comply with BOCA as interpreted by the Contractor.
4. Question: What is the size & thickness of the required tile.
Answer: The tile shall be a 12" x 12" tile with a thickness of 1/8".
5. Question: This is regarding question #8. We have not found anything in the specs to indicate that this is required. We certainly can do this. Can you point us to the section pertaining to the requirements and also provide the proper documents to submit with the bid?
Answer: Please see Addendum 1.
Addenda No. 2
TMA – Water Filtration Building
August 21, 2025 www.cpengineers.com
6. Question: Drawing C002 lists FFE at 458.75 but drawing S1 lists FFE at 457? Which one is correct? Please Clarify.
Answer: The finished floor elevation should be 458.15�. This will put the walkway to the water filter building at 457.15� and the steps into the building will be at 457.80�.
7. Question: Can you please provide more information on the well supplying the fire hydrant and the non treated 2" line? 1) Do we need to supply a well pump? If so what is required? 2) How deep is the well? 3) Is electric need to be run to the well?
Answer: It is not required to supply the well pump. The depth should be at a minimum of 3 feet.
Electric will not need to run to the well.
8. Question: 1) Drawing C002 grading note 11 is misleading. You stated the site work is unclassified but this note makes it sound like it is classified excavation. Can you confirm if we hit un-rippable rock as mentioned in the note that any redesign would result in a change order based on the new design. And if blasting is needed we would be paid for the permit and blasting. 2) Does this note cover rock only or does it also cover any unsuitable soils that we may encounter?
Answer: The site is a historic fill area. The excavation is considered unclassified, and bidders are responsible for conducting their own investigations to determine site conditions. We are not aware of any rock on-site.
9. Question: Would welded wire fabric or fiber reinforced concrete be acceptable in lieu of #3 rebar 18" on center each way?
Answer: It shall be as indicated on the drawings
10. Question: Drawing A1 pan South has a garage door tag but not door is shown. Please confirm that there is only 3 garage doors and that is an inadvertent tag.
Answer: Confirmed, this was an inadvertent tag.
August 21, 2025 www.cpengineers.com
11. Question: 1) Who owns the water meter pit? If the GC owns that please give us a location of where it is located and what the requirements are for it. 2) Please confirm only one meter pit is required for the 3/4" water line.
Answer: The water authority owns the meter pit. There is only one pit required.
12. Question: On civil drawing C002 shows an 8" pvc water line servicing the fire hydrant but the detail on M001 shows 6" ductile iron pipe. Please confirm what is required.
Answer: 8� PVC is required.
13. Question: Is the owner responsible for paying Power company costs?
Answer: No. The owner is not responsible for any power company costs. The contractor shall be responsible for all coordination with the power company and for payment of any associated costs. Electrical contractor should include the cost in their bid.
14. Question: Can you providing the forms that are required to be submitted with the bid?
Answer: The forms are available through the DCED and PADEP agency websites. It is the responsibility of each bidder to obtain the current versions directly from the issuing agencies and include them in the bid package.
15. Question: Is there a estimated Electrical contract amount?
Answer: The estimated value of the electrical contract is $100,000
16. Question: 1) Do we own temporary electric and lights (including to the office trailer) or does the electrical prime. Typically, it is the EC prime, but not always so I hate to assume. 2) Is the owner paying for the temporary water and electric cost and if not does the EC pay electric and we pay water? 3) Do we have to provide the owner with a job office trailer for a CM or owner�s rep? 4)
Do we need a large office trailer for project meetings, or will they have meetings somewhere else? 5) Will we be required to provide a construction fence? 6) Will we need to provide dumpsters for the EC or does each prime own their own? 7) Will we need to provide any phones/internet to the office trailer for the owner or other primes to use? 8) Is concrete and earthwork testing required and if so is the owner paying for any 3rd party testing? Typically they owner pays to prevent conflicts of interest, but not always. 9) Is the project warranty the standard 1 year or do we need a 2nd year maintenance bond? 10) Can the
Professional/Pollution limit requirements be changed form a $5M max to a $2M max.
August 21, 2025 www.cpengineers.com
Answer: 1) There won't be a need for temporary electric and lights, if it is, the contractor shall provide. 2)The work is for the Thompsontown Municipal Authority, water provided at no cost.
Power will not be available on day one. Once service is established, TMA will pay for electric usage. 3) A job office trailer for a Construction Manager or Owner�s Representative is not required. 4) Project meetings will be held across the street at the Borough Hall. A large office trailer is not required for this purpose. 5) Contractors are required to secure their own work area. No special fencing requirements are specified 6) Each contractor is responsible for providing their own dumpsters. 7) No phone or internet service is required to be provided for the Owner or other prime contractors. 8) No. 9) Standard 1-year warranty applies unless otherwise specified in the contract documents. 10) The maximum requirement will be reduced from $5 million to $2 million.
17. Question: Can Siemens Switchgear be used for Panels?
Answer: Yes. �Or equal� and �substitution� provisions apply. All equipment must comply with the project specifications.
18. Question: (3) EUH units will come with factory installed disc. on unit so, the wall mount disc. will not be required? so, we can install the thermostat's were the disc. is shown?
Answer: Provide as indicated in the drawings.
19. Question: Will the EC be responsible for the concrete pad for this unit?
Answer: Yes.
20. Question: The building consist of 2x6 walls w/ dry wall, raceway specs call out indoor alum rigid conduit? if the conduits are install inside walls can they be EMT? is there any NEMA ratings for the rooms? the ceiling is also plywood painted by owner if conduits are run above ceiling in truss area can they also be EMT?
Answer: SCH 40 PVC Conduits are to be supplied and installed for underground electrical duct bank. Above ground indoors as well as outdoors shall be Rigid Aluminum Conduit.
August 21, 2025 www.cpengineers.com
DRAWING REVISIONS
No drawing revisions as part of this Addendum.
SPECIFICATION REVISIONS
1) Add Section 05 60 10 – Bronze Plaque, in place of previous version.
2) Add Section 08 33 00 – CORROSION RESISTANT ROLLING SERVICE DOORS.
3) Add Section 08 54 14 – WOOD CLAD, DOUBLE HUNG WINDOWS, in place of previous version.
END OF ADDENDA
CP Engineers, LLC 056010-1 1007.013
Section 056010 Bronze Plaque
Part 1 - General
1.01 SUMMARY
A. This Section includes a bronze plaque to be installed near the front door with associated hardware as specified herein.
1.02 SUBMITTALS
A. Submit a �to scale� rendering or rubbing of the finished plaque along with shop drawing.
B. Shop Drawing: Provide a shop drawing which details mounting hardware and location for approval.
Part 2 - Products
2.01 Plaque: To be cast in Bronze (No Lead Content)
A. Depth to be 5/16 inch minimum
B. Size: 8� x 16�
C. Border to be single line bevel
D. Background to be Dark Oxide.
E. Printing to be raised and polished with the following text:
F. Mount to be blind.
THOMPSONTOWN MUNICIPAL AUTHORITY
Booster Pump Station
Authority Board
Francis Ranck, Chairman
Rick O�Neal, Vice Chairman
Seth Hart, Treasurer
Gary Benner
John Dressler
Michael Feltman
Norman Lukens
Staff
Roger Stutts, Operator
Waynett Dunn, Accounting
Seth Mosbey, Solicitor
Engineering Team
Brent Musser, PLS
Brian Book, PE
Andy Lenard, PE
Joe Guagno, PE
CP Engineers, LLC 056010-2 1007.013
G. Acceptable Manufacturers:
1. Gemini Inc.
2. Or Equal
Part 3 - Execution
3.01 INSTALLATION
A. Review finished plaque with Owner�s representative.
B. Mount on agreed location near front door.
END OF SECTION 056010
CP Engineers, LLC 083300-1 1007.013
SECTION 08 33 00
CORROSION RESISTANT ROLLING SERVICE DOORS
PART 1 GENERAL
1.1 SUMMARY
A. Section Includes: Manual overhead rolling doors.
B. Related Sections:
1. 05 50 00 Metal Fabrications. Door opening jamb and head members
2. 06 10 00 Rough Carpentry. Door opening jamb and head members
3. 08 31 00 Access Doors and Panels. Access doors
C. Products That May Be Supplied, But Are Not Installed Under This Section:
1. Control Station
1.2 SYSTEM DESCRIPTION
A. Design Requirements:
1. Wind Loading:
a. Doors to withstand up to 100PSF design wind load
2. Cycle Life:
a. Standard construction for normal use of up to 20 cycles per day maximum, and a life cycle expectancy of up to 50,000
1.3 SUBMITTALS
A. Reference Section 01 33 00 Submittal Procedures; submit the following items:
1. Product Data
2. Shop Drawings
1.4 QUALITY ASSURANCE
A. Qualifications:
1. Manufacturer Qualifications: ISO 9001:2015 registered and a minimum of five years’ experience in producing doors of the type specified
2. Installer Qualifications: Manufacturer's approval
1.5 DELIVERY STORAGE AND HANDLING
A. Reference Section 01 66 00 Product Storage and Handling Requirements
B. Follow manufacturer's instructions
1.6 WARRANTY
CP Engineers, LLC 083300-2 1007.013
A. Standard Warranty: Two years from date of shipment against defects in material and workmanship.
B. Maintenance: Submit for owner’s consideration and acceptance of a maintenance service agreement for installed products.
PART 2 PRODUCTS
2.1 MANUFACTURER
A. Manufacturer:
Cornell: 24 Elmwood Avenue, Mountain Top, PA 18707 Telephone: (800) 233-
B. Alternates:
1. Cookson
2. Clopay Building Products
3. Overhead Door Corporation
2.2
2.3 MATERIALS
A. Curtain:
10’ x 10’ insulated, fiber-reinforced plastic
B. Endlocks:
Alternate slats each secured with two ¼” (6.35 mm) stainless steel rivets. Fabricate interlocking sections with high strength stamped 304 series stainless steel. Provide endlocks/windlocks as required to meet specified wind load.
C. Bottom Bar
1. Configuration:
a. Extruded Aluminum: Extruded aluminum alloy 6063-T5
2. Finish:
a. Aluminum: White anodized
D. Guides:
1. Fabrication:
a. Structural aluminum Provide windlock bars as required, removable bellmouths, and bottom bar stoppers of same material. Stainless steel fasteners to be used for assembly bolts
2. Finish:
CP Engineers, LLC 083300-3 1007.013
a. Aluminum: White anodized
E. Counterbalance Shaft Assembly:
1. Barrel: Steel pipe capable of supporting curtain load with maximum deflection of 0.03 inches per foot (2.5 mm per meter) of width
2. Spring Balance: Oil-tempered, heat-treated steel helical torsion spring assembly designed for proper balance of door to ensure that maximum effort to operate will not exceed 25 lbs (110 N). Provide wheel for applying and adjusting spring torque.
3. Finish:
a. Corrosion Inhibitive: Zirconium treatment followed by a corrosion inhibitive baked-on zinc-rich gray polyester powder coat; minimum 2.5 mils (0.065 mm) cured film thickness
F. Brackets:
Fabricate from minimum 3/16 inch (5 mm) stainless steel plate with permanently lubricated ball or roller bearings at rotating support points to support counterbalance shaft assembly and form end closures. Corrosion inhibitive zirconium treatment required for all bearings.
1. Finish:
a. 4 type 304 Stainless Steel
G. Hood:
Aluminum with reinforced top and bottom edges. Provide intermediate support brackets as required.
1. Finish:
A. Aluminum: White anodized
2.4 OPERATION
A. Motor - Continuous Use - Model SGHNX (Super Duty Gear Head NEMA 4X) Operator:
1. UL Listed NEMA 4X rated
2. The operator must not extend above or below the door coil when mounted front-of-coil.
3. Totally Enclosed Non-Ventilated gear head operator(s) rated (1/2) to (2) hp as recommended by door manufacture for size and type of door, 120Volts, 3Phase.
4. Provide complete with electric motor and factory pre-wired motor control terminals, maintenance free solenoid actuated brake, emergency manual chain hoist provided up to 2 hp and control station(s).
5. Motor shall be high starting torque, industrial type, with overload protection.
6. Primary speed reduction shall be heavy-duty gears running in grease or oil bath with mechanical braking to hold the door in any position.
CP Engineers, LLC 083300-4 1007.013
7. When equipped, the emergency manual chain hoist assembly is automatically disengaged when motor is energized. A disconnect chain shall not be required to engage or release the manual chain hoist.
8. Operator drive and door driven sprockets shall be provided with minimum #50 roller chain.
9. Operator shall be capable of driving the door at a speed of up to 9” per second or as recommended for door size.
10. Fully adjustable, driven linear screw type cam limit switch mechanism shall synchronize the operator with the door. The motor shall be removable without affecting the limit switch settings.
11. The electrical contractor shall mount the control station(s) and supply the appropriate disconnect switch, all conduit and wiring per the overhead door wiring instructions.
12. Stainless Steel Corrosion Resistant finish to withstand low pressure direct spray
1. Surface mounted: "Open/Close/Stop" push buttons; NEMA 4X (standard)
2.5 ACCESSORIES
A. Locking:
2. Padlockable slide bolt on fascia side of bottom bar at each jamb extending into slots in guides. Provide interlock switches or motor mounted interlock switches.
B. Vision Panels: 36 x 26 inch rectangular acrylic panes set with double sided foam glazing tape and secured with retaining clips and rivets. Refer to drawings for number and placement.
C. Interior Aesthetic Covers:
1. Operator and Bracket Mechanism Cover: Aluminum sheet metal cover to enclose exposed operating components at coil area of unit. Finish matching hood.
PART 3 EXECUTION
3.1 EXAMINATION
A. Examine substrates upon which work will be installed and verify conditions are in accordance with approved shop drawings
B. Coordinate with responsible entity to perform corrective work on unsatisfactory substrates
CP Engineers, LLC 083300-5 1007.013
C. Commencement of work by installer is acceptance of substrate
3.2 INSTALLATION
A. Install door and operating equipment with necessary hardware, anchors, inserts, hangers and supports
B. Follow manufacturer's installation instructions
3.3 ADJUSTING
A. Following completion of installation, including related work by others, lubricate, test, and adjust doors for ease of operation, free from warp, twist, or distortion
3.4 CLEANING
A. Clean surfaces soiled by work as recommended by manufacturer
B. Remove surplus materials and debris from the site
3.5 DEMONSTRATION
A. Demonstrate proper operation to Owner's Representative
B. Instruct Owner's Representative in maintenance procedures
END OF SECTION
CP Engineers, LLC 085414-1 1007.013
DIVISION 08 � DOORS & WINDOWS
SECTION 08 54 14 � WOOD CLAD, DOUBLE HUNG WINDOWS
PART 1 GENERAL
1.01 RELATED SECTIONS
A. Section 01 13 30�Submittal Procedures
B. Section 06 10 00�Rough Carpentry
C. Section 06 20 00�Finished Carpentry
D. Section 09 90 00�Paint
1.02 REFERENCES
A. American Society for Testing and Materials (ASTM):
1. E 283: Standard Test Method for Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
2. E 330: Standard Test Method for Structural Performance of Exterior Windows, Curtains Walls, and Doors by Uniform Static Air Pressure Difference.
3. E 547: Standard Test Method for Water Penetration of Exterior Windows, Curtain
Walls, and Doors by Cyclic Static Air Pressure Differential.
4. E 774: Specification for Sealed Insulated Glass Units. 5. E 1886: Standard Test
Method for Performance of Exterior Windows, Curtain Walls, Doors, and Storm
Shutters Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials
6. E 1996: Standard Specifications for Performance of Exterior Windows, Curtain
Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in
Hurricanes
7. C 1036: Standard Specification for Flat Glass.
B. Window and Door Manufactures Association (WDMA): I.S.4: Industry Standard for
Water Repellent Preservative Treatment for Millwork.
C. Sealed Insulating Glass Manufactures Association / Insulating Glass Certification
Council (SIGMA / IGCC).
1.03 SYSTEM DESCRIPTION
A. Impact Zone 3 Certification Requirements:
1. Window Units shall be designed to comply with 101/I.S.2-97, 101/I.S. 2/NAFS-
02, and 101/I.S.2/A440-05
CP Engineers, LLC 085414-2 1007.13
a. Double Hung: H-LC +55/-65 rating
b. Transom: F-LC +55/-65 rating
c. Picture: F-LC +55/-65 rating
2. Air leakage shall not exceed the following when tested at 1.57 psf according to
ASTM E 283:
a 0.30 cfm per square foot of frame.
3. No water penetration shall occur when units are tested at the following pressure according to ASTM E 547: a. Double Hung: 8.25 psf a Transom: 8.25 psf b Picture: 8.25 psf
4. Units shall be designed to comply with ASTM E330 for structural performance when tested at the following pressures:
a. Double Hung: +82.5/-97.5 psf
b. Transom: +82.5/-97.5 psf
c. Picture: +82.5/-97.5 psf
5. Missile Impact at Missile Level D complies with ASTM E1886-05, ASTM E 1886-06, ASTM E1996-02, ASTM E1996-05, ASTM E1996-06.
6. Impact Pressure Cycling at +55/-65 psf, complies with ASTM E1886-02, ASTM
E1886-05, ASTM E1886-06, ASTM E1996-02, ASTM E1996-05, ASTM E1996-06.
7. Thermal Unit �U� Value, .35 or less, complies with NFRC Certification.
8. Forced Entry Resistance, complies with ASTM F588-04.
1.04 SUBMITTALS
A. Shop Drawings: Submit shop drawings under provisions of Section 01 13 30.
B. Product Data: Submit catalog data under provisions of Section 01 13 30.
1.05 QUALITY ASSURANCE
A. Regulatory Requirements: Emergency Egress or Rescue: Comply with requirements for sleeping units of 2009 North Carolina Building Code.
1.06 STORAGE AND HANDLING
A. Prime or seal wood surfaces, including surface to be concealed by wall construction, if more than thirty (30) days will expire between delivery and installation.
B. Store window units in an upright position in a clean and dry storage area above ground and protect from weather.
1.07 WARRANTY
CP Engineers, LLC 085414-3 1007.013
A. Windows shall be warranted to be free from defects in manufacturing, materials, and workmanship for a period of ten (10) years from purchase date.
B. Window glass shall be warranted to be free from defects in manufacturing, materials and workmanship for period of twenty (20) years from the purchase date.
PART 2 PRODUCTS
2.01 Acceptable Manufacturers
A. Ultrex® Double Hung as manufactured by Integrity Windows and Doors, Fargo, North
Dakota. Operating sash tilt to interior for cleaning or removal.
B. Andersen Corporation, Bayport, Mn.
C. Or Equal
2.02 FRAME DESCRIPTION
A. Interior: Clear pine interior surfaces.
1. Kiln dried to a moisture content no greater than twelve (12) percent at the time of fabrication.
2. Water repellent preservative treated in accordance with ANSI / NWWDA I.S.4-94.
B. Exterior: Frame exterior aluminum clad with 0.050� (1.3mm) thick extruded aluminum.
C. Frame thickness: 1 27/32� (47mm) head and jambs
2.03 SASH DESCRIPTION
A. Clear pine interior surfaces.
1. Kiln dried to a moisture content no greater than twelve (12) percent at the time of fabrication.
2. Water repellent preservative treated in accordance with ANSI / NWWDA I.S.4-94.
B. Sash exterior aluminum clad with 0.050� (1.3mm) thick extruded aluminum.
C. Composite sash thickness: Sash thickness: 1 3/4� (44mm).
2.04 GLAZING
A. Select quality complying with ASTM C1036. Insulating glass SIGMA/IGCC certified to performance level CBA when tested in accordance with ASTM E2190.
CP Engineers, LLC 085414-4 1007.013
B. Triple-Pane and Dual Pane thickness: 7/8�
C. Glass fill: Air with capillary tubes, Argon.
D. Glazing seal: Silicone bedding at exterior and interior.
E. Optional Impact glazing zone for winds up to 130 miles per hour. Glass is laminated insulated Low EII with Argon, consisting of annealed or tempered glass to the exterior and laminated glass to the interior. The laminated glass is made up of glass with either a SGP or PVB laminate layer between. The interior and exterior glazing compound is silicone , in a sandwich style glazing system.
2.05 FINISH
A. Exterior: Aluminum clad. Fluoropolymer modified acrylic topcoat over a primer. Meets
AAMA 2605 requirements.
B. Interior: White interior factory finish.
2.06 HARDWARE
A. Balance System: Coil spring block and tackle with nylon cord and glass filled nylon shoe and steel locking clutch.
B. Jamb Track: Pultruded extrusion.
C. Lock: High pressure zinc die-cast cam lock and keeper. Finish: Phosphate coated and electrostatically painted.
1. Color: White.
D. Tilt latches: Spring loaded latches for release of sash located at checkrail.
1. Color: White.
2.07 WEATHER STRIP
A. Frame, sash stiles, and meeting rails, sealed with flexible bulb gasket. Bottom and top rails sealed with flexible leaf gasket.
2.08 JAMB EXTENSION
A. Furnish jamb extension 6-9/16 (167 mm) factory installed for all but 2x8 Shear walls.
Furnish jamb extensions in the field for 2x8 walls, shipped loose
B. Finish: Bare wood; White interior factory finish.
CP Engineers, LLC 085414-5 1007.013
PART 3 EXECUTION
3.01 EXAMINATION
A. Verification of Conditions: Before Installation, verify openings are plumb, square, and of proper dimension as required. Report frame defects or unsuitable conditions before proceeding.
3.02 INSTALLATION
A. Assemble and install window unit according to manufacturer�s instructions and reviewed shop drawings.
B. Install sealant and related backing materials at perimeter of unit or assembly. Do not use expansive foam sealant.
C. Install accessory items as required.
D. Use finish nails to apply wood trim and moldings.
3.03 CLEANING
A. Remove visible labels and adhesive residue according to manufacturer�s instructions.
3.04 PROTECTING INSTALLED CONSTRUCTION
A. Protect windows from damage by chemicals, solvents, paint, or other construction operations that may cause damage.
END OF SECTION 085414
PAGE LEFT INTENTIONALLY BLANK
| Addenda No. 2 |
| 22 - Section 05 60 10-8-13-2025 |
| Section 056010 |
| Bronze Plaque |
| Part 1 - General |
| 1.01 SUMMARY |
| A. This Section includes a bronze plaque to be installed near the front door with associated hardware as specified herein. |
| 1.02 SUBMITTALS |
| A. Submit a “to scale” rendering or rubbing of the finished plaque along with shop drawing. |
| B. Shop Drawing: Provide a shop drawing which details mounting hardware and location for approval. |
| Part 2 - Products |
| 2.01 Plaque: To be cast in Bronze (No Lead Content) |
| A. Depth to be 5/16 inch minimum |
| B. Size: 8” x 16” |
| C. Border to be single line bevel |
| D. Background to be Dark Oxide. |
| E. Printing to be raised and polished with the following text: |
| F. Mount to be blind. |
| G. Acceptable Manufacturers: |
| Part 3 - Execution |
| 3.01 INSTALLATION |
| A. Review finished plaque with Owner’s representative. |
| B. Mount on agreed location near front door. |
| Section 08 33 00 |
| 28 - Section 08 54 14-rev 8-12-2025 |
| DIVISION 08 – DOORS & WINDOWS |
| SECTION 08 54 14 – WOOD CLAD, DOUBLE HUNG WINDOWS |
| PART 1 GENERAL |
| PART 2 PRODUCTS |
| PART 3 EXECUTION |