This is Amendment 4 to Request for Lease Proposal (RLP) 2CA1644 for the Federal Public Defender's office space in Los Angeles, CA, issued by GSA on February 12, 2025. The amendment removes the maximum number of floors restriction and provides detailed technical specifications for the space.

The amendment specifies ceiling heights must be between 8'6" and 10'0" with 2x2 suspended acoustic ceilings and LED lighting throughout. It requires 26-28 oz carpet tile, painted walls, and vinyl base as standard finishes. Two partition types are specified: Type A (standard drywall with batt insulation) and Type B (slab-to-slab acoustically sealed with STC 45 rating). Security requirements include card readers and cameras at 3 locations per floor. Each typical office must have 5 duplex outlets and 3 data drops (2 inside, 1 in corridor). The amendment maintains priority for window offices and requires the contractor to notify the agency of any spaces not meeting ceiling height requirements during design.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT NO. 4

TO REQUEST FOR LEASE PROPOSAL NO. 2CA1644

February 12, 2025

General Services Administration Federal Public Defender (FPD)

Los Angeles, CA

Request for Lease Proposal (RLP) 2CA1644 is amended to remove the maximum number of floors. The first sentence of RLP Exhibit B, is hereby deleted and replaced with the following:

“All spaces shall have ceiling heights between 8'-6" and 10'-0". Contractor to advise agency during the design process, of spaces not meeting the ceiling height criteria. 2x2 suspended acoustic ceiling throughout with 2x2 LED light fixtures unless otherwise noted in remarks. 26-28 oz carpet tile (CPT) unless otherwise noted.

Painted walls, vinyl base (VB) typical unless otherwise noted in remarks. See special requirements for millwork, supplemental HVAC, and other special planning assumptions. Priority for window offices is provided.

Partition Types: Type A: Standard drywall partition on metal studs with 5/8" drywall both sides.

The partition penetrates the ceiling plane with batt insulation over the partition top.

Type B: Slab to slab acoustically sealed partition consisting of 1 layer gypsum board each side of metal studs with R-13 batt insulation inside wall cavity. Minimum STC 45. Correspondingly doors in Partition Type B are to have 40 STC rating and are detailed with Sound seals and door sweeps as required to meet the specification.

Prep doors for card readers and camera package at 3 locations per flr (2 at suite entries and 1 at stairwell) plus additional locations as noted below at computer rooms, forensic work room, etc.

Power and data for a typical office: 5 duplex outlets, 2 data drops inside the office and one on the corridor side for booking software. Monitors, kitchen equipment, copy equipment, (etc.) by agency.”

------------------------------------------------- END OF RLP CHANGES ----------------------------------------

Authorized By: Maria Dent, Lease Contracting Officer

Please sign below, acknowledging receipt of this form, and return to:

Timothy.Pavek@gsa.gov & Maria.Dent@gsa.gov

RECEIPT OF AMENDMENT NUMBER 4 IS HEREBY ACKNOWLEDGED

BY THE OFFEROR:

OFFEROR NAME (printed)

OFFEROR SIGNATURE

File details come from the government source that posted it. Updated .