2C.2 RLP 36C10F24R0007 Appendix A_2_2 Bay Pines VAHCS Fixtures Guide Sarasota FL OPC 1_26_2024.pdf

PDF 415 KB Posted

Attached to
X1DB--Sarasota Outpatient Clinic (PACT ACT) 131, 724 ANSI/BOMA
Solicitation number
36C10F24R0007
Issued by

About this file

This document outlines finishes and fixtures standards for the Bay Pines VA Health Care System. Key details include specifications for ceiling tiles, lighting fixtures, restroom finishes such as toilets, sinks, and partitions. Door and hardware requirements include frames, kickplates, locks, hinges, and door closers. Notes provide additional guidance regarding material standards, labeling, firestopping, exit lights, and egress lighting. Millwork standards require premium grade laminate and concealed joining.

The related federal contract opportunity is for the Sarasota Outpatient Clinic project for the Department of Veterans Affairs Office of Construction and Facilities Management. The solicitation number is provided along with the name and description of the opportunity.

View the file

Other files

File Type Posted
36C10F24R0007_2.docx DOCX document
36C10F24R0007 - Sarasota FL OPC - RLP Amendment 2 - Q_A Matrix - 2.26.2024.pdf PDF
2D 36C10F24R0007 - Sarasota FL OPC - RLP Amendment No 2 - Room Data Matrix - 2.26.2024.xlsx XLSX spreadsheet
36C10F24R0007 - Sarasota FL OPC - RLP Amendment 2 - Pre-bid Meeting Presentation - 2.8.2024.pdf PDF
36C10F24R0007 - Sarasota FL OPC - RLP Amendment No 2 - 2.26.2024.pdf PDF
36C10F24R0007 - Sarasota FL OPC - RLP Amendment 2 - Pre-Bid Attendance Sheets - 2.8.2024.pdf PDF
36C10F24R0007 - Sarasota FL OPC - RLP Amendment 2 -Pre-Bid Meeting Transcript - 2.8.2024.pdf PDF
36C10F24R0007_1.docx DOCX document
36C10F24R0007 - Sarasota FL OPC - Amendment No 1 - 1 February 2024.pdf PDF
0 RLP 36C10F24R0007 RLP Sarasota FL OPC 1_26_2024.pdf PDF
36C10F24R0007.docx DOCX document
5 RLP 36C10F24R0007 Offering Entity Acknowledgement Form Sarasota FL OPC 1_26_2024.pdf PDF
2F RLP 36C10F24R0007 Appendix A_4_1 OIT Data Center Design Narrative Sarasota FL OPC 1_26_2024.pdf PDF
15 RLP 36C10F24R0007 GSA Template 3516 Solicitation Provisions Sarasota FL OPC 1_26_2024.pdf PDF
17 RLP 36C10F24R0007 GSA Form 12000 for Prelease FPLS Evaluation Sarasota FL OPC 1_26_2024.pdf PDF
14 RLP 36C10F24R0007 VA Handbook 6500_6 Appendix D VA Rules of Behavior Sarasota FL OPC 1_26_2024.pdf PDF
3 RLP 36C10F24R0007 Appendix A_6 Conceptual Floor Plan Sarasota FL OPC 1_26_2024.pdf PDF
8 RLP 36C10F24R0007 Attachment No 1 to GSA Form 1364 Sarasota FL OPC 1_26_.2024.xlsx XLSX spreadsheet
7 RLP 36C10F24R0007 Proposal to Lease Space GSA Form 1364 Sarasota FL OPC 1_26_2024.pdf PDF
2B RLP 36C10F24R0007 Appendix A_1 Project Contents List PRC Sarasota FL OPC 1_26_2024.pdf PDF
9 RLP 36C10F24R0007 GSA Form 1217 Lessors Annual Cost Statement Sarasota FL OPC 1_26_2024.pdf PDF
2D RLP 36C10F24R0007 Appendix A_3 Room Data Matrix RDM Sarasota FL OPC 1_26_2024.pdf PDF
18 RLP 36C10F24R0007 Certification of Building Energy Performance Sarasota FL OPC 1_26_2024.pdf PDF
2G RLP 36C10F24R0007 Appendix A_5 Facility Level Security FSL II Sarasota FL OPC 1_26_2024.pdf PDF
2A RLP 36C10F24R0007 Appendix A Program for Design PFD Sarasota FL OPC 1_26_2024.pdf PDF
2 RLP 36C10F24R0007 Cover Page for Agency Specific Requirements ASR Sarasota FL OPC 1_26_2024.pdf PDF
13 RLP 36C10F24R0007 GSA Form 527 Contractors Quals and Financial Info Sarasota FL OPC 1_26_2024.pdf PDF
16 RLP 36C10F24R0007 GSA Template 3517B General Clauses Mod General Clauses Sarasota FL OPC 1_26_2024.pdf PDF
20 RLP 36C10F24R0007 Covered Telecom Equip or Services Rep Sarasota FL OPC 1_26_2024.pdf PDF
6 RLP 36C10F24R0007 Offeror Proposal Compliance Matrix Sarasota FL OPC 1_26_2024.pdf PDF
1 RLP 36C10F24R0007 Lease Sarasota FL OPC 1_26_2024.pdf PDF
12 RLP 36C10F24R0007 SF 330 Architect Engineer Qualifications Sarasota FL OPC 1_26_2024.pdf PDF
2E RLP 36C10F24R0007 Appendix A_4 VA CBOC Info Transp Sys Specs Sarasota FL OPC 1_26_2024.pdf PDF
19 RLP 36C10F24R0007 Sarasota County Wage Determination Sarasota FL OPC 1_26_2024.pdf PDF
4 RLP 36C10F24R0007 Appendix B VA Janitorial and Site Management Services Sarasota FL OPC 1_26_2024.pdf PDF
10 RLP 36C10F24R0007 Form VA 10091 VA FSC Vendor File Request Form Sarasota FL OPC 1_26_2024.pdf PDF
21 RLP 36C10F24R0007 Pre bid Conference Registration Form Sarasota FL OPC 1_26_2024.pdf PDF
2C.1 RLP 36C10F24R0007 Appendix A_2_1 Bay Pines VAHCS Finish Standards Dec 2023 Sarasota FL OPC 1_26_2024.pdf PDF
2C RLP 36C10F24R0007 Appendix A_2 Lease Design Narrative LDN Sarasota FL OPC 1_26_2024.pdf PDF
11 RLP 36C10F24R0007 Past Performance Questionnaire Sarasota FL OPC 1_26_2024.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bay Pines VA Health Care System Finishes & Fixtures

Standards http://upload.wikimedia.org/wikipedia/commons/0/03/US-DeptOfVeteransAffairs-Seal.jpg

Date of Issue: 2021 08 04

1 | P a g e

Finishes and Fixtures Standards

Table of Contents

Ceiling Finishes and fixtures Page 2-3

Ceiling tile Paint

Restroom Finishes Page 3-4 Tile Paint Accessories

Door & Hardware Page 5-9 Door Accessories & finishes

Notes Page 9-13

2 | P a g e

Ceiling Finishes and Light Fixtures:

Use Code no. Item No. Image ACT C-1 Armstrong 1728 24”Wx

24”L x 5/8” Thick, Med;

fine Fissured

ACT Clean/Sterile C-2 Armstrong 868B 24”W x 24” L x 5/8” Thick;

smooth

Grid C-5 Armstrong PRELUDE

XL/XL HRC, .050 white, Fire Guard, 15/16” width

Gypsum Board Ceilings

P-16

Ceiling Bright White

SW7007

Corridors, patient rooms, exam rooms

LT-1 Lithonia Lighting

2BZL2-30L-MVOLT-

SLD-LP830

Storage, supply, and offices

LT-2 Lithonia Lighting EPANL 22 34L 40K 2x2 Flat Panel

Patient rooms and alcoves

LT-3 Lithonia Lighting LDN6 6” round open and wallwasher

Patient rooms and alcoves

LT-4 Lithonia Lighting LDN4 4” Round open and wallwasher

Restrooms LT-5 Lightology, Pipeline 2 vanity center feed with power 5w/foot Finish: Satin Nickel Various Lengths.

Color: 3000K

3 | P a g e

Finishes and Fixtures Standards

Wattage: 5W

MFR ID: P2WDP-5W-

C4R-34-30K-SN

ITEM #: EDG819081

Patient Room Lights LT-6 Modular Services Company - Clarity overbed light fixture Model # MDL-

C4LV22LEDT8120

Restroom Finishes:

All Water Closets

RR-8

American Standard Huron with EverClean Back 1.28 - 1.6 gpf EverClean Universal Flushometer Toilet Concealed Toilet flush valve

All Water Closets

RR-9

American Standard Selectronic Sensor Operated Concealed Toilet Flush Valve 606B-322. PK00.HAC hard-wired AC transformer single Lavatory

RR-10

Bradley Verge LVA Series, Finish Mojave

Multi sink lavatory RR-11 Bradley Verge LVA Series, Finish Mojave

All Lavatory

RR-12

American Standard Paradigm Selectronic integrated proximity lavatory faucet.

Hard wired

All Urinals

RR-13

American Standard FloWise Universal Urinal. 6590.001

4 | P a g e

All Urinals

RR-14

American Standard Sensor Operated Urinal Flush Valve, Model number 6063.013.022

Eye Wash RR-16 Speakman SE-575-DP pull down eyewash

Water Fountain RR-17 Elkay EXH2O Bottle Filling

Station with Single ADA Cooler Filtered 8 GPH Light Gray Model: LMABF8WSLK

Toilet Partitions RR-18 Hiny Hiders

Color Linen Strikes: 3” stainless steel emergency access Stirrup Brackets – Stainless steel double ear, Latches – occupancy indicator, Hinges- Stealth integral hinge

Door & Hardware Finishes:

Use Code no. Item No. Image

5 | P a g e

Finishes and Fixtures Standards

Door frame guards F-1 InPro Custom Form Door Frame: .040” (1mm) thick rigid vinyl Standard Heights: 3’ (.91m), 4’ (1.22m), 8’ (2.44m)

Door edge protector E-2 InPro Stainless Steel Door

Edge Protector Styles: L-Shaped & U-

Shaped Standard Heights: 3’

(.91m), 8’ (2.44m)

Astragal AS-1 National Guard 553 beveled edge astragal set on active leaf. Stainless steel. To be installed on all double doors.

Door edge protector E-1 InPro Stainless Steel Door

Edge Protector 96” Full Height

Kickplate K-1 InPro Stainless Steel

Kickplate: Custom Form Door, standard type 430, 16 gauge

Kickplate Heavy Use Areas

K-2 Palladium Kickplate .060” Custom Form

Wood Door D-1 Rotary Sliced Birch Factory Clear Finish

6 | P a g e

Finishes and Fixtures Standards

Doors – Fire Doors D-2 Mesker metal doors and frame

Healthcare Occupancy Office Lock

H-1

Corbin-Russwin ML2051 series Function: Lock is always open on inside, locked by button on inside.

Storeroom Lock

H-2

Corbin-Russwin ML2057 series Function: always locked on outside, always open inside, key retract latch bolt

Bathroom Privacy Lock

H-3

Corbin-Russwin ML2030 series Function: Bathroom lock, button locks from inside, square stock key or thumb latch unlocks. It will be left unlocked upon leaving room.

Passage Set

H-4

Corbin-Russwin ML2010 series, Function: Passage.

Two levers, always unlocked.

Business Occupancy Classroom Lock

H-5

Corbin-Russwin ML2055 series, Function: always open inside, can be locked and unlocked outside with key

7 | P a g e

Finishes and Fixtures Standards

Healthcare Occupancy Electrical Combination Lock

H-11

Schlage Cobra pushbutton lock. Model: CO-100M.

The lock must comply with our 7-pin small format best cylinders.

Business Occupancy Electrical Combination Lock

H-12

Schlage Cobra pushbutton lock. Model: CO-100C.

The lock must comply with our 7-pin small format best cylinders.

Exit Hardware

H-13

Von Duprin 99 series, surface mounted.

Generally, storeroom function preferred; when hardware needs to be left unlocked it can be dogged down

Door Closure H-14 IR/LCN Series 4040 super smoothie. Function ADA compliance and heavy-duty use.

Door Closure H-15 IR/LCN Series 4041XP hold opens.

Door Hinge H-16 Hager CB1191 Concealed

Bearing - Standard Weight, Non-rising removable pin with button tip and plug

8 | P a g e

Notes

Material: Rubber compound with abundant natural fillers and environmentally compatible color pigments

Surface: Smooth Color: Tone-on-tone color visual

Door Hinge H-17 Hager 780 Series – Concealed leaf

• All Healthcare Occupancy locks shall be mortise style.

• Where key locks are required,the locks must accept a Medeco 7-pin interchangeable core. The industry nomenclature is “I/C small format 7 pin core”.

• Exit Hardware used on this facility must also accept the Best cylinders. It should be surface mounted, and not mortise style. Vertical locking rods, when used, must also be surface mounted. Guards must be provided.

• All double doors shall have manual flush bolts.

• For door closers, it is recommended to use IR/LCN heavy-duty.

• Label the cover plates of all electrical receptacles and switches both inside and outside with their circuit numbers (on the outside of the receptacle cover and a label inside the outlet box).

• Design penetrations of fire and smoke rated partitions to utilize manufacturer’s products that are able to accept additional cables without removing firestopping materials. Example: EZ- Path® Fire Rated Pathways.

• All Exit lights shall be LED Green in color self-diagnostic testing. Battery backup is not allowed.

• All fire extinguisher cabinets shall be fully recessed mounted, non-locking, capable of holding a 4A-60BC fire extinguisher. (TIL- Section 10 44 13) Install cabinet so that bottom of cabinet is 914 mm (36 inches) above finished floor.

• All egress lights shall be LED in style and wall mounted.

9 | P a g e

Finishes and Fixtures Standards

Roll Size: 0.12 inches (3mm high foot traffic or 2mm) thickness,

39.37 feet by 48 inches (12m by 1.22m)

Back of Roll: Smooth, double-sanded back Homogeneous: Yes, mottled, single durometer Limited Wear Warranty: 5 years Hardness: ASTM D2240, Shore type A, required ≥ 75 Static Load: Per ASTM F970 Standard Test Method for Static Load

Limit, residual compression, when tested with 800 lbs, ≤ 0.005”

ISO 14001: Manufacturer shall be ISO 14001 Environmental Management Systems Certified

PVC Free: Products shall contain no polyvinyl chloride Abrasion Resistance: Taber abrasion test, ASTM D3389, H-18 wheel, 500 gram load, 1000 cycles, gram weight loss ≤ 0.4 Slip Resistance: Static coefficient of friction (James Test): ASTM D2047, ≥ 0.5 Bacteria Resistance: Products shall be resistant to bacteria, fungi, and micro-organism activity, according to ASTM E2180 and ASTM G21

Halogen Free: Products shall contain no halogens Sound Absorption: ISO 140-8 Footfall Sound Absorption, 8 dB Burn Resistance: Cigarette and solder burn resistance Flammability: ASTM E648; NFPA 253; NBSIR 75 950, ≥ 0.45 watts per square centimeter, Class 1 Smoke Density: ASTM E662, NFPA 258, NBS smoke density, < 450 Asbestos Free: Products shall contain no asbestos Non Hazardous: Flooring shall be made without any chemicals that may be hazardous or containing any teratogenic, mutagenic or any other ingredients known to be carcinogenic

Cleaning: Flooring surface shall have the ability to be cleaned and maintained without the use of any chemicals that may be hazardous or containing any teratogenic, mutagenic or any other ingredients known to be carcinogenic. Manufacturer shall make available a cleaning system that effectively cleans the flooring surface using water, cleaning pads and a suitable cleaning machine, without the use of factory and/or field-applied coatings.

Shine: Higher shine surfaces can be achieved by dry buffing without any artificial topical applied coatings

Stain Resistance: Resistant to stains from healthcare related disinfectants and chemicals to include but not limited to rust, Betadine, Methylene Blue, Alcohol based hand sanitizer.

Manufacturer to provide samples for testing without manually or mechanically applied coatings, sealers or floor finish on the test sample.

Indoor Air Quality: Flooring shall be GREENGUARD Gold certified for indoor air quality

Installation: Flooring installers must be manufacturer-approved Adhesive: Water-based acrylic adhesive must be low VOC (volatile organic compound) and resistant to 85% relative humidity

10 | P a g e

Millwork Standards Millwork must be commercial grade quality and follow below premium guidelines.

Warranties are required by the Manufacturer.

Use Premium grade laminate millwork.

• HPL (high pressure laminate), nominal 0.7 mm thick

• blend and match continuous pattern (material permitting).

• Semi exposed parts not including backs of flush doors to be HPL 0.7mm thermoset overlay, any paper or particle board must be sealed or painted or paper impregnated overlay. Concealed parts, mill option.

• Premium grade direction matching (dependent on finish selected)

• Balanced construction for unrestrained components, shall contain an odd number of layers with the substrate forming the inner core layer. Same machine direction on double sided substrate components.

• Hot melt applied HPL edge banding shall be primed before application for proper adhesion unless the hot melt adhesive used has been specially formulated for HPL without requiring pre-application of a primer. Edge-bands to the extent of standard length of materials, must run the full length of a single vertical or horizontal member without a joint or splice. Finish all front edges of cases with a single piece of laminate, without joints at the corners. Thermally fused and wrapped.

• Toe kicks chamfer the lower edge for durability. Use concealed 35 mm cup hinges; adjustable metal shelves must be recessed and multiple min. 5mm diameter, dual pin holes provided.

• Joinery, case body members: Tops, exposed ends, and bottoms (finished ends on casework shall be integral, not applied secondarily) Any fasteners will not be visible on any exposed or semi-exposed parts; exposed end corner details and face frame attachment shall use a fully concealed interlocking mechanical system

• Cabinet backs – Floor Standing, side bound, captured in grooves; securely fastened to top and bottom, Full overlay, plant-on backs: min. 12.7mm (1/2”) thick attached with min #8 low root, high thread (not drywall) screws spaced max. 200mm (8”) on center. Edge of back shall not be exposed on finished ends.

• Gap tolerances: doors, panels, frames, door to door is 3.2mm (1/8”) horizontal in vertical alignment tolerance 0.8mm (1/32”) Max variation in flushness of adjacent doors 0.8m (1/32”), Flatness of exposed case doors max deviation and between factory assemble joints .13mm (.005”), between fixed exposed components .4mm (1/64”) max gap between each end of adjustable shelf and case side 1.6mm (1/16”).