260003_Drawings.pdf

PDF 2 MB Posted

Attached to
TINKER AFB MAC BOA WWYK260003 REPAIR ROOF, ELECT, HVAC & RESTROOMS B#4019
Solicitation number
FA813726R0028
Issued by

About this file

This document is a set of architectural design drawings and construction plans for a Design-Build project at Tinker Air Force Base in Oklahoma.

The project (WWYK260003) involves the repair of roof, electrical, HVAC, and restroom systems in Building 4019, a metal warehouse structure constructed circa 2004. Key work includes: roof repair and replacement of insulation and vinyl liner (Class A, per IBC 2024); demolition and replacement of wall and ceiling insulation; removal of two overhead doors with infill using insulated metal panels; installation of a new 3-foot by 7-foot hollow metal entry door on the east wall with panic hardware; provision of splash blocks at downspouts; site grading to achieve minimum 5% slope away from the building; restriping of the north parking lot to accommodate ABA-compliant parking spaces and accessible routes; and comprehensive restroom renovations including new fixtures, tile cleaning and sanitization, and installation of TAFB standard accessories. Interior finishes include rubber base flooring, painted drywall partitions, and new windows. The project location is identified on the vicinity map with contractor haul routes and future truck gate designations specified. The design is dated 11 March 2026 and prepared by the 72nd Air Base Wing Civil Engineer Directorate under Air Force Materiel Command.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REVIEWED BY:

REVIEWED BY:

USING AGENCY:

ASBESTOS EVALUATION:

SAFETY:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

INDUSTRIAL HYGIENE:

DATE:

PROJECT DRAWING INDEX SIGNATURES

CORROSION ENGINEER: (CECE)

CE OPERATIONS: (CECO)

COMMUNICATIONS: (COMM)

CHIEF ENGINEER DIR: (CECE)

CHIEF DESIGN BRANCH: (CECE)

DESIGN MANAGER: (CECE)

ZONE MANAGER:

CONSTRUCTION MANAGEMENT: (CECE)

ENVIRONMENTAL:

BASE CIVIL ENGINEER: (CE)

FIRE DEPARTMENT

GENERAL1. BRAND NAMES: REFERENCE TO SPECIFIC BRAND NAMES

OR COMPANIES IS FOR THE PURPOSE OF ESTABLISHING

MINIMUM QUALITY STANDARDS, IDENTIFICATION AND

GUIDANCE AND IS NOT INTENDED TO LIMIT SELECTION OF

OTHER MANUFACTURERS THAT ARE EQUAL OR EXCEED

THE SPECIFIED ITEMS IN TERMS OF PHYSICAL

PROPERTIES, INCLUDING, COLOR RANGE, FINISH,

DURABILITY, APPEARANCE, PERFORMANCE

CHARACTERISTICS, AND OTHER FACTORS. OTHER

PRODUCTS, MATERIALS, COLORS AND SYSTEMS, MAY BE

SUBMITTED FOR EVALUATION AND

APPROVAL/DISAPPROVAL BY THE CONTRACTING OFFICER.

2. THIS SET OF CONSTRUCTION DOCUMENTS SHALL BE

CONSIDERED AS A WHOLE IN THAT THE GENERAL

CONTRACTOR AND ALL THE SUB-CONTRACTORS ARE

RESPONSIBLE FOR THE INFORMATION PRESENTED ON ALL

SHEETS ON THE SET OF DRAWINGS AND ALL SECTIONS OF

THE SPECIFICATIONS.

3. THE CONTRACTOR IS RESPONSIBLE FOR ERECTING ALL

CONSTRUCTION FENCING AND BARRICADES AS REQUIRED

TO PROTECT CONSTRUCTION MATERIAL AND TO PREVENT

ANY UNAUTHORIZED PERSONNEL FROM ENTERING THE

CONSTRUCTION SITE.

4. ANY DAMAGE TO THE EXISTING GROUNDS OR FACILITIES

CAUSED BY CONSTRUCTION TRAFFIC OR ANY

CONSTRUCTION OPERATION SHALL BE REPAIRED OR

REPLACED BY THE CONTRACTOR TO MATCH OR EXCEED

EXISTING CONDITIONS AT NO ADDITIONAL COST TO THE

GOVERNMENT.

5. ALL WORK NOTED & LOCATED IN THESE DOCS SHALL BE

UNDERSTOOD BY THE CONTRACTOR TO REQUIRE ALL NEW

LABOR & MATERIALS UNLESS SPECIFICALLY NOTED TO BE

"EXISTING" OR "BY OTHERS".

WWYK260003

REPAIR ROOF, ELECT,

HVAC & RESTROOMS, B4019

KEY PLAN:

GENERAL NOTES:

DISCIPLINE

PROJECT

LOCATION

1 G-101 GENERAL NOTES & VICINITY MAP

SHT.SEQ. SHEET TITLE

OF

TI

NK

ER

A

IR

F

OR

CE

B

AS

E, O

KL

AH

OM

A

PR

O

JE

C

T

IN

FO

R

M

AT

IO

N

D

ES

IG

N

F

IL

E

LO

C

AT

IO

N

R

EV

IS

IO

N S

M

AR

K

D

ES

IG

N

G R

O U

P:

D R

AW

N

B Y:

C H

EC

KE

D B

Y:

D

ES

IG

N

ED

B

Y:

D

AT

E D

ES

C

R

IP

TI

O

N

1 2 3 4 5

E

D

C

B

A

M

AN

AG

EM

EN

T

IN

FO

R M

AT

IO

N

1 2 3 4 5

E

D

C

B

A

IS

SU

E D

AT

E:

SHEET

SHEET NUMBER

SH

EE

T

TI

TL

E

AIR FORCE MATERIEL COMMAND

72 ABW CIVIL ENGINEER DIRECTORATE

TINKER AFB, OK

DESIGN

BUILD

W W

YK

RE

PA

IR

R

OO

F, E

LE

CT

HV

AC

R

ES

TR

OO

MS

, B

M

AR

TE

PA

- S R

M

G-101

S

ST

AR

R

J

BI

R C

H U

M

En gr

\D es ig n\

\2

6\

\0

_S up po rt\

0_ 3_

D ra w in gs

GE

NE

RA

L N

OT

ES

AN

D

VI

CI

NI

TY

M

AP

01 04

C-101

ARCHITECTURAL DEMOLITION PLANAD-101

AERIAL IMAGE OF B4019 WITH UTILTIES

A-101 ARCHITECTURAL NEW WORK PLAN44019

44045

Hi llt op R d.

SE 59th St. R U

N W

AY

8/

RUNWAY 13/31

TA

XI

W

AY

G

TAXIW

AY H

TAXIWAY B

TAXIWAY C

TAXIWAY M

TA

XI

W

AY

K

TAXIWAY E

TAXIWAY A

TA

XIW

AY E

E

TAXIWAY F

TAXIWAY D

TAXIWAY E

TAXIWAY J

TA

XI

W

AY

G

TAXIWAY A

TAXIW

AY H

TAXIWAY C

TAXIWAY D

TAXIWAY EE

TAXIWAY F

Elm C reek

Crutcho Creek

Kuhlman Creek

Soldier Creek

Kuhlman Creek

Elm C reek

East Crutcho Creek

Elm Creek

El m

C re ek

Elm Creek

Elm C reek

Elm CreekElm C reek

Ku hlm an C re ek

Ea st

C ru tc ho

C re ek

Elm C ree k

West Crutcho Creek

W es t C ru tc ho

C re ek

Elm Creek

Soldier Creek

Elm C reek

Soldier CreekSoldier Creek

Ea st

C ru tc ho

C re ek

Elm Creek

Ea st

C ru tc ho

C re ek

East C rutcho C reek

Soldier Creek

So ld ie r C re ek

East C rutch o Creek

Soldier C reek

Soldier C reek

So ld ie r C re ek

East Crutcho Creek

416506

21222121

59475946

11401128

62540

61089

838837

62509

62528

62523

62501X

43774

62512

62516

62525

3592135916

99999

62543

32101

71086

53902

50414

55300

56601

930G

948-E

911-E

948-W

61019

911-W

33001

35913

62501

65672

930S

45134

43609

42116

62517

62515

62526

62527

62503

62513

61289

62542

62501OK

11289

62501

15930

15908

15904

15904

15908

15908

15904

15904

15908

62502

41046

62501

62514

62501

61018

71089

45134

96022

43120

41157

44045

45815

40592

43610

62522

41163

15930

15930

11824

Arnold St.

Ea st

D r.

SE 74th St

SE 59th St.

Ai r D ep ot

Patrol Rd.

St af f D r.

Reserve Rd.

5th Ave

"A " A ve

M un iti on s R d.

W ar eh ou se R d.

"B " A ve

7th St.

"H " A ve

M cN ar ne y Av e.

Mitchell Ave

Al er t R d.

Co ok

A ve

W es t D r.

"E "A ve

Extender Dr.

Sentry Rd.

34th St.

Twining Dr.

5th Ave.

Jo ne s

Globemaster Dr.

To w er R d.

Vanaman Rd.

In du st ria l B lv d.

So ut h St

1st St.

Do ol itt le

A ve

Pi cn ic R d.

Ja m es D r.

W ol fe D r.

Ai r D ep ot

Ai r D ep ot

"D " A ve

Perimeter Rd.

Rapcon Rd.

Reserve Rd

"L " A ve

Mercury Rd.

1st St.

Br ow n Dr

Po nd

R d.

O ld

A ir

De po t

Airey Dr.

Bradley Dr.

Entrance Road "C"

Entrance Road "A"

"C " A ve

"C " A ve

Vandenberg Dr.

Hi llt op R d.

Do rm ito ry

R d.

Dormitory Rd.

"M " A ve

Chennault Dr.

M itc he ll A ve

Spaatz Dr.

Co m m od ity D r.

Doolittle Ave

W hi te D r.

3rd Ave.

"D " D riv e

Ba ll

Pa rk

R d.

Joint STARS Dr.

Ai r D ep ot

B lv d

Turbine Dr. Turbine Dr.

Central Plant Dr.

6th St.6th St.

Falco n Dr.

Blackb ird

Dr.

W ey la nd

L oo p

Pegasus Dr.

Thunderbolt D r.

Munitions Rd. Ext.

Codding Rd.

Starlifter Dr.

Chidlaw Ct.

Co rs ai r D r.

Ra pt or Ct

N ig ht H aw k

Ct

Ph an to m

D r.

Fr an kl in

Po w er ho us e

Dr

Sk ym as te r D r.

Spaatz Ct.

La w re nc e

M un de ll

Nabors Dr.

In tr ud er

D r.

M cN ic kl e

M ill er D r.

Ta il

Fe at he r D r.

Holden Dr.

Ai re y C ir.

Smith Ct.

Ra ve n Ct

Air Dep ot Ai r D ep ot

Vanaman Rd.

1st St.

1st St.

TAXIWAY F

Ra w li ng s A ve

Mitc he ll A ve

Mercury Rd.

Ra ily ar d

Rd

He rc ul es

R d.

"F " A ve

Pr op ul sio n Dr

Stratofortress Dr.

96021

Arnold St.

62501W 62501E

SE 59th St.

TINKER AFB, OK

VICINITY MAP

BASE

OPERATIONS

B240

CONTRACTING

B3

GOTT

GATE

TINKER GATE

PASS & ID B6611

HRUSKOCY

GATE

EAKER GATE

FIRE DEPARTMENT

B117

VANCE

GATE

LIBERATOR GATE

HOPE

GATE

LEGEND

CONTRACTOR

HAUL ROUTE

LANCER

GATE

TRUCK GATE

PIAZZA GATE

BASE CIVIL

ENGINEER

B400

PROJECT

LOCATION

(FUTURE

HAUL ROUTE)

(F

UT

UR

E

HA

UL

R

OU

TE

FUTURE

TRUCK GATE

FUTURE

HAUL ROUTE

OF

TI

NK

ER

A

IR

F

OR

CE

B

AS

E, O

KL

AH

OM

A

PR

O

JE

C

T

IN

FO

R

M

AT

IO

N

D

ES

IG

N

F

IL

E

LO

C

AT

IO

N

R

EV

IS

IO

N S

M

AR

K

D

ES

IG

N

G R

O U

P:

D R

AW

N

B Y:

C H

EC

KE

D B

Y:

D

ES

IG

N

ED

B

Y:

D

AT

E D

ES

C

R

IP

TI

O

N

1 2 3 4 5

E

D

C

B

A

M

AN

AG

EM

EN

T

IN

FO

R M

AT

IO

N

1 2 3 4 5

E

D

C

B

A

IS

SU

E D

AT

E:

SHEET

SHEET NUMBER

SH

EE

T

TI

TL

E

AIR FORCE MATERIEL COMMAND

TINKER AFB, OK

AIR FORCE MATERIEL COMMAND

72 ABW CIVIL ENGINEER DIRECTORATE

DESIGN

BUILD

W W

YK

RE

PA

IR

R

OO

F, E

LE

CT

HV

AC

R

ES

TR

OO

MS

, B

M

AR

T

EP

A-

SR

M

M N

O

EL

C-101

S S

TA

R

R

J B

IR

C

H U

M

En gr

\D es ig n\

\2

6\

\0

_S up po rt\

0_ 3_

D ra w in gs

AE

RI

AL

IM

AG

E

OF

B4

9 W

IT

H

UT

ILI

TI

ES

NE

W

W

OR

K

02 04

GENERAL NOTES

1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS

FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING

CONDITIONS FOR ACCURACY.

2. METAL BUILDING WAS CONSTRUCTED CIRCA 2004. SITUATED IN GRASSED AREA WITH

CEDAR TREES ON SOUTH SIDE AND DECIDUOUS TREES ON EAST SIDE. BUILDING

CURRENTLY HAS OPEN WAREHOUSE STORAGE AREA, SMALL OFFICE WITH WINDOW

AIR-CONDITIONING UNIT, AND TWO RESTROOMS. METAL BUILDING STRUCTURE WITH VINYL

LINER IS EXPOSED TO INTERIOR OF THE BUILDING.

C-101

AERIAL IMAGE OF B4019 WITH UTILITIES NEW WORK

SCALE:

KEYED NOTES

SITE AND UTILITIES IMPROVEMENTS - RESTRIPE EXISTING NORTH PARKING LOT TO

ACCOMMODATE STANDARD VEHICLE SIZES AND REQUIRED ABA PARKING SPACES.

3 STANDARD AND 1 VAN SPACE, AS PER ABA F208.2 MINIMUM NUMBER (OF

ACCESSIBLE PARKING SPACES) 76-100 - PARKING FACILITY TOTAL - MINUIMUM

NUMBER.

PROVIDE A 5' WIDE SIDEWALK FOR PEDESTRIANS FROM THE REMOTE PARKING

LOTS TO BUILDING 4019, AS PER TAFB STANDARD DETAIL FOR PCC SIDEWALK.

PROVIDE TRENCH DRAIN AND RE-GRADE THE ASPHALT DRIVE AT THE SOUTHWEST

CORNER OF THE BUILDING TO MITIGATE WATER DRAINAGE AWAY FROM THE

BUILDING.

REGRADE THE SOIL ALONG THE BUILDING PERIMETER WALLS TO ACHIEVE A

MINIMUM 5 % SLOPE (1:20 AWAY FROM THE BUILDING FOR AT LEAST 10 FT. [REFER

IBC 2024, 1804.4 SITE GRADING]

TRIM THE EXISTING TREE BRANCHES AWAY FROM THE BUILDING GUTTERS ALONG

THE EAST AND SOUTH WALLS.

THE CONTRACTOR SHALL INSPECT AND REPAIR ALL ROOF LEAKS AND PROPERLY

PATCH EVERY AREA LEFT EXPOSED AFTER THE REMOVAL OF MECHANICAL

EQUIPMENT, USING MATERIAL THAT MATCH THE EXISTING ROOF COLOR,

PROFILE AND GAUGE.

PROVIDE HANDICAP SIGNAGE AS REQUIRED TO MEET ABA COMPLIANCE.

PROVIDE ABA COMPLIANT CURB, RAMPS AND CROSSWALK AS PER SDDCTEA

PAMPLET 55-17.

1 7 sc

B4019

NK

ER

A

IR

F

OR

CE

B

AS

E, O

KL

AH

OM

A

PR

O

JE

C

T

IN

FO

R

M

AT

IO

N

D

ES

IG

N

F

IL

E

LO

C

AT

IO

N

R

EV

IS

IO

N S

M

AR

K

D

ES

IG

N

G R

O U

P:

D R

AW

N

B Y:

C H

EC

KE

D B

Y:

D

ES

IG

N

ED

B

Y:

D

AT

E D

ES

C

R

IP

TI

O

N

1 2 3 4 5

E

D

C

B

A

M

AN

AG

EM

EN

T

IN

FO

R M

AT

IO

N

1 2 3 4 5

E

D

C

B

A

IS

SU

E D

AT

E:

SHEET

SHEET NUMBER

SH

EE

T

TI

TL

E

AIR FORCE MATERIEL COMMAND

TINKER AFB, OK

AIR FORCE MATERIEL COMMAND

72 ABW CIVIL ENGINEER DIRECTORATE

DESIGN

BUILD

W W

YK

RE

PA

IR

R

OO

F, E

LE

CT

HV

AC

R

ES

TR

OO

MS

, B

M

AR

T

EP

A-

SR

M

M N

O

EL

AD-101

S S

TA

R

R

J B

IR

C

H U

M

En gr

\D es ig n\

\2

6\

\0

_S up po rt\

0_ 3_

D ra w in gs

AR

CH

IT

EC

TU

RA

L

DE

MO

LIT

IO

N

PL

AN

03 04

GENERAL NOTES

1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS

FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING

CONDITIONS FOR ACCURACY.

2. METAL BUILDING WAS CONSTRUCTED CIRCA 2004. SITUATED IN GRASSED AREA WITH CEDAR

TREES ON SOUTH SIDE AND DECIDUOUS TREES ON EAST SIDE. BUILDING CURRENTLY HAS

OPEN WAREHOUSE STORAGE AREA, SMALL OFFICE WITH WINDOW AIR-CONDITIONING UNIT,

AND TWO RESTROOMS. METAL BUILDING STRUCTURE WITH VINYL LINER IS EXPOSED TO

INTERIOR OF THE BUILDING.

AD-101

ARCHITECTURAL DEMOLITION PLAN

SCALE: 1/8" = 1'-0"

SPLASH BLOCKS ARE MISSING FROM SOUTH ELEVATION. SOIL HAS ERODED AWAY FROM

THE SOUTH SIDE DOWNSPOUT LOCATIONS. PREPARE FOR NEW SPASHBLOCKS.

EXISTING TO REMAIN, EIFS WALL INSULATION SYSTEM W/ 36-INCH-HIGH FACE BRICK

WAINSCOT WRAPPING BUILDING PERIMETER W/ STAINS ON EXTERIOR WALLS.

EXISTING TO REMAIN, SMALL AWNING AT EACH HOLLOW METAL MAN DOORS. DOORS W/

GLASS VISION PANEL, PUSH BAR & LEVER HARDWARE .

EXISTING SMALL AWNING AT HOLLOW METAL MAN DOOR. DOOR W/ GLASS VISION PANEL,

PUSH BAR & LEVER HARDWARE - REMOVE, PREPARE FOR DOOR INFILL.

EXISTING TO REMAIN, SLIDING WINDOWS LOCATED ON NORTH ELEVATION.

EXPOSED METAL BUILDING STRUCTURE W/ EXPOSED VINYL LINER W/ WALL INSULATION

BATT INSULATION SYSTEM. DEMOLISH EXISTING WALL INSULATION, CEILING INSULATION, &

VINYL LINER. PREPARE FOR REPLACEMENT.

EXPOSED CONCRETE FLOOR, TO REMAIN. PREPARE FOR NEW FINISHES.

OVERHEAD DOORS LOCATED ON NORTH AND SOUTH ELEVATION. REMOVE TWO

OVERHEAD DOORS. PREPARE FOR INFILL.

EXISTING TO REMAIN, INTERIOR PAINTED DRYWALL PARTITIONS EXTEND APPROXIMATELY

10 FEET HIGH. ACOUSTIC CEILING TILE, 2X2 GRID, APPROXIMATELY 8 FEET HIGH WITHIN

THESE ROOMS. PREPARE FOR FINISHES.

EXISTING TO REMAIN, HOLLOW METAL RESTROOM DOORS W/PUSH HARDWARE AND

CLOSERS. PREPARE FOR FINISHES.

RESTROOM ABA FLOOR TRANSITION MISSING. PREPARE FOR NEW TRANSITION.

EXISTING TO REMAIN, RESTROOM FLOOR W/ 8X8 CERAMIC TILES. WALLS HAVE 4X4

CERAMIC TILE WAINSCOT W/ PAINTED DRYWALL, ABOVE.

EXISTING TO REMAIN, METAL TOILET PARTITIONS.

EXISTING LAVATORY W/ SLOPED PIPE ENCLOSURE BELOW. EXISTING GRAB BARS IN

HANDICAP STALL. FRAMED MIRROR ABOVE LAVATORY.

EXISTING RESTROOM ACCESSORIES ARE NOT TAFB STANDARD. REMOVE EXISTING

RESTROOM ACCESSORIES, PREPARE DRYWALL FOR NEW FINISHES AND ACCESSORIES.

REMOVE SECTION OF METAL BUILDING WALL W/FACE BRICK WAINSCOT AT EAST SIDE AT

LOCATION OF NEW ENTRY DOOR. PREPARE FOR NEW ENTRY DOOR.

REMOVE MECHANICAL DUCT. PREPARE FOR NEW DUCTWORK.

KEYED NOTES

10 11 10 11

5 2

5 28

1 2 1

MECHANICAL

DUCT

NK

ER

A

IR

F

OR

CE

B

AS

E, O

KL

AH

OM

A

PR

O

JE

C

T

IN

FO

R

M

AT

IO

N

D

ES

IG

N

F

IL

E

LO

C

AT

IO

N

R

EV

IS

IO

N S

M

AR

K

D

ES

IG

N

G R

O U

P:

D R

AW

N

B Y:

C H

EC

KE

D B

Y:

D

ES

IG

N

ED

B

Y:

D

AT

E D

ES

C

R

IP

TI

O

N

1 2 3 4 5

E

D

C

B

A

M

AN

AG

EM

EN

T

IN

FO

R M

AT

IO

N

1 2 3 4 5

E

D

C

B

A

IS

SU

E D

AT

E:

SHEET

SHEET NUMBER

SH

EE

T

TI

TL

E

AIR FORCE MATERIEL COMMAND

TINKER AFB, OK

AIR FORCE MATERIEL COMMAND

72 ABW CIVIL ENGINEER DIRECTORATE

DESIGN

BUILD

W W

YK

RE

PA

IR

R

OO

F, E

LE

CT

HV

AC

R

ES

TR

OO

MS

, B

M

AR

T

EP

A-

SR

M

M N

O

EL

A-101

S S

TA

R

R

J B

IR

C

H U

M

En gr

\D es ig n\

\2

6\

\0

_S up po rt\

0_ 3_

D ra w in gs

AR

CH

IT

EC

TU

RA

L

NE

W W

OR

K

PL

AN

04 04

GENERAL NOTES

1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS

FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING

CONDITIONS FOR ACCURACY.

2. METAL BUILDING WAS CONSTRUCTED CIRCA 2004. SITUATED IN GRASSED AREA WITH CEDAR

TREES ON SOUTH SIDE AND DECIDUOUS TREES ON EAST SIDE. BUILDING CURRENTLY HAS

OPEN WAREHOUSE STORAGE AREA, SMALL OFFICE WITH WINDOW AIR-CONDITIONING UNIT,

AND TWO RESTROOMS. METAL BUILDING STRUCTURE WITH VINYL LINER IS EXPOSED TO

INTERIOR OF THE BUILDING.

A-101

ARCHITECTURAL NEW WORK PLAN

SCALE: 1/8" = 1'-0"

PROVIDE FLOOR MARKING AT FIRE ALARM SYSTEM, FIRE SPRINKLER RISER, ELECTRICAL

PANELS, AND DATA SYSTEM LOCATIONS TO PROVIDE REQUIRED CLEARANCE FROM THESE

SYSTEMS.

PROVIDE NEW 3 FT x 7 FT HOLLOW METAL ENTRY DOOR WITH LITE ON EAST WALL WITH

HOLLOW METAL FRAME, PAINTED. PROVIDE PANIC HARDWARE WITH BEST LOCK CORE.

TAFB KEY SHOP TO KEY CORE. PROVIDE ABA COMPLIANT THRESHOLD. EXTERIOR PAINT:

SW 7705 WHEAT PENNY & INTERIOR PAINT: SW 7067 CITY SCAPE.

PROVIDE SPLASH BLOCKS AT EACH DOWNSPOUT. SLOPE GRADE TO DRAIN.

REPLACE INSULATION & VINYL LINER W/ NEW METAL BUILDING INSULATION AND LINER

SYSTEM, CLASS A, AS REQUIRED BY IBC 2024, 720.3 INSULATION, AT UNDERSIDE OF ROOF

AND INTERIOR WALLS.

INFILL EXISTING ROUGH OPENINGS AT OVERHEAD DOORS & ONE MAN-DOOR WITH

INSULATED METAL PANEL INFILL, PAINTED ON METAL FRAMING. METAL PANEL COLOR: SW

9102 QUINOA. PROVIDE METAL BUILDING VINYL LINER, CLASS A ON R-13 BATT INSULATION +

R-6.5 CONTINUOUS INSULATION, AS REQUIRED BY IBC 2024, 720.3 INSULATION. SEAL AND

PROVIDE WEATHERSTRIPPING AT THE PERIMETER OF INFILL. REFER STRUCTURAL DESIGN

NARRATIVE.

PROVIDE RUBBER BASE, COLOR: ARMSTRONG, FLAG STONE ON EXISTING GYPSUM

WALLBOARD. PAINT ALL DRYWALL PARTITIONS WITHIN BUILDING. COLOR: SW 7647

CRUSHED ICE CHIP.

PRIME AND PAINT HOLLOW METAL DOORS. INTERIOR COLOR: SW 7067 CITY SCAPE &

EXTERIOR COLOR: SW 7705 WHEAT PENNY. PROTECT HARDWARE DURING CONSTRUCTION.

CLEAN & SANITIZE ALL CERAMIC TILE GROUT. CLEAN & SANITIZE THE CERAMIC TILE FLOOR

& WALL TILE.

PROVIDE & INSTALL TAFB STANDARD PAPER TOWEL DISPENSER, TOILET PAPER

DISPENSER, SOAP DISPENSER, TRASH CAN, ETC.

PROVIDE 4'-0" x 4'-0" HOLLOW METAL FRAMED WINDOW, WITH INSULATED GLASS. BOTTOM

OF WINDOWS AT 42 INCHES AFF. WINDOWS TO FIT BETWEEN PURLINS SIMILAR TO

EXISTING CONDITION ON NORTH WALL. EXTERIOR PAINT: SW 7705 WHEAT PENNY &

INTERIOR PAINT: SW 7067 CITY SCAPE.

PROVIDE CONCRETE STOOP AT NEW ENTRY DOOR - 4'-0" x 5'-0", MINIMUM WITH 1

20 SLOPE

MINIMUM AWAY FROM DOOR. STOOP FINISH FLOOR TO BE 12 INCH BELOW FINISH FLOOR.

KEYED NOTES

1 9 9 8 85

5 5

3 333

3 333

4 4

FI

RE

R

IS

ER

A

RE

A

COMM.

BOX

FURNITURE PARTITION

BY VENDOR, SET 5'

FROM EXISTING BACK

OF ELECTRICAL PANELS

CL

EA

R

ZO

NE

4'-0" 12'-0" 2'-0"

3'-0" 6'-0" 4'-0" 22'-0" 4'-0" 3'-5" 3'-0" 11'-10" 4'-0" 20'-9"

38'-0" +/- 30'-9"

FURNITURE PARTITION

BY VENDOR

4'- 6"

4'- 0"

8'-

4'-

0"

'-2

3'- 0"

'-6

2'-0"

6'-0"

4'- 0"

4'- 0"

R.

O.

CLEAR

ZONE

CL

EA

R

ZO

NE

R.

O.

5'- 0"

CL

EA

R

WATER LINE

FIRE STANDPIPE

ELECTRICAL

PANELS

NEW FIRE

ALARM PANEL

6 6

7 7

7 7

5'- 0"

Sheets and Views
G101
04-260003-A101-A101.pdf
Sheets and Views
A101
03-260003-AD101-AD101.pdf
Sheets and Views
AD101
02-260003-C101-C101.pdf
Sheets and Views
C101
04-260003-A101-A101.pdf
Sheets and Views
A101

File details come from the government source that posted it. Updated .