25M029CN Building M458 Paint and Flooring Repairs PS.pdf

PDF 51 KB Posted

Attached to
Building M457 & M458 Paint and Flooring Repairs
Solicitation number
N40085-26-R-9040
Issued by

About this file

This document is a finishes specification sheet for an interior construction project under NAVFAC (Naval Facilities Engineering Command) oversight. It specifies approved basis-of-design materials and installation requirements for paint, flooring, and related interior finishes across multiple space types including primary walls, sleeping rooms, offices, and shared spaces.

The specification details specific paint products including Benjamin Moore 1548 Classic Gray for primary walls and 1552 River Reflections for sleeping rooms, Sherwin Williams SW 7026 Griffin for door frames and SW 7102 White Flour for GWB and exposed ceilings. Flooring materials include Mannington luxury vinyl tile products (Crisscross Zoom Charcoal for sleeping rooms and Access Stone Linear Stone Shale for offices), with Schluter transition strips and Johnsonite rubber base specified. Epoxy resinous flooring using Dur-A-Flex Dur-A-Quartz Q28-23 is required for lounge and shared spaces. The document establishes that listed manufacturers represent approved basis of design only; equivalent products from other manufacturers may be substituted with NAVFAC Contracting Officer approval. Critical requirements include: all materials must be installed per manufacturer specifications; all interior finishes in vertical exit ways must meet minimum Class A rating; electrical panels and expansion joints must be spray painted to match adjacent wall colors; flooring transitions must comply with ABA guidelines and be centered under doors; and contractors must order materials in advance to prevent scheduling delays. The contractor bears responsibility for timely material procurement to avoid project delays.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NAME LOCATION MANUFACTURER MODEL COLOR SIZE

PAINT PRIMARY WALLS BENJAMIN MOORE 1548 CLASSIC GRAY -

ACCENT PAINT SLEEPING ROOMS BENJAMIN MOORE 1552 RIVER REFLECTIONS -

PAINT DOOR FRAMES SHERWIN WILLIAMS SW 7026 GRIFFIN -

PAINT GWB & EXPOSED CEILINGS SHERWIN WILLIAMS SW 7102 WHITE FLOUR -

WALL GRAPHIC LOUNGE FIND YOUR LEVEL LINDSEY II BEIGE -

LUXURY VINYL TILE SLEEPING ROOMS MANNINGTON CRISSCROSS ZOOM CHARCOAL -

LUXURY VINYL TILE OFFICES MANNINGTON ACCESS STONE LINEAR STONE SHALE -

RUBBER BASE PRIMARY BASE JOHNSONITE 283 TOAST -

TRANSITION STRIP LVT TO TILE SCHLUTER RENO-U AEU 35 SATIN ANODIZED -

TRANSITION STRIP LVT TO CONCRETE OR EPOXY SCHLUTER RENO-U AEU 100 SATIN ANODIZED -

CORNER GUARD OUTSIDE CORNERS INPRO TYPE 430 STAINLESS STEEL -

EPOXY RESINOUS FLOORING LOUNGE & SHARED SPACES DUR-A-FLEX DUR-A-QUARTZ Q28-23 -

GENERAL NOTES

• FINISHES INDICATED ARE THE APPROVED BASIS OF

DESIGN TO CONVEY COLOR, PATTERN, TEXTURE AND

SALIENT CHARACTERISTICS ONLY. THE LISTING OF

MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT

THE SELECTION OF PRODUCTS PROVIDED BY OTHER

MANUFACTURERS. PRODUCTS MEETING THESE CRITERIA

WILL BE CONSIDERED AND MUST BE REVIEWED BY THE

PROJECT MANAHGER AND APPROVED BY THE NAVFAC

CONTRACTING OFFICER.

FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO

ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S

RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO

AVOID DELAYS.

• FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO

ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S

RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO

AVOID DELAYS.

• ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT

LOBBIES, AND EXIT CORRIDORS MUST MEET MINIMUM

CLASS A RATING.

• SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND

EXPANSION JOINTS TO MATCH THE ADJACENT WALL

COLOR. PANELS PAINTED BY BRUSH ARE NOT

ACCEPTABLE.

• ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER

MANUFACTURER'S INSTALLATION REQUIREMENTS.

• ALL FLOORING TRANSITIONS MUST MEET ABA

GUIDELINES. FLOORING TRANSITIONS OCCURRING UNDER

DOORS MUST BE CENTERED UNDER DOOR.

PRODUCT SPECIFICATIONS

File details come from the government source that posted it. Updated .