This is a Project Description document for a federal construction contract at Marine Corps Base, Camp Lejeune, North Carolina. The project involves the demolition and replacement of two 7.5-ton Air Handling Units (AHU) and associated condensing units located at Building G560. The scope of work includes replacing manual and controlled outdoor air dampers, capping existing isolated exhaust ducts, replacing bathroom exhaust fans and grills, installing all new refrigerant and condensate lines, replacing the electric panel for circuit breakers, replacing condenser disconnects, and supplying a concrete pad for the condensing units. The AHU will be located in an open/panel ceiling configuration, while the condensing units will be positioned exterior to the building.
The supervision requirements allow for one qualified individual to fill the combined roles of Superintendent, Quality Control Manager, and Safety & Health Officer, provided that person meets all qualifications as defined in the project specification. The work is restricted to Department of Defense community distribution only, as indicated by the document header.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 25R9057 Amend 0003.pdf | ||
| 25R9057 Amend 0003.pdf | ||
| 26R9057 Amend 0002.pdf | ||
| 26R9057 Amend0001.pdf | ||
| 26R9057 G560 RFP.pdf | ||
| 25R9057 G560 RFP.pdf | ||
| N4008525B0081 Dwgs.pdf | ||
| 25-0081 ACM REPORT.pdf | ||
| CONSTRUCTION PROJECT_ 25-0081 Building G560 Mechanical Replacement.pdf | ||
| N4008525B0081 Specs.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DISTRIBUTION: DoW COMMUNITY ONLY
PROJECT DESCRIPTION
The work includes - Demolish and replace two 7.5-ton AHU and condensing units. AHU located in an open/panel ceiling, condensing units located exterior to building. Replace manual and controlled outdoor air dampers. Cap exists existing isolated exhaust duct. Replace bathroom exhaust fan and grills. All new refrigerant and condensate lines. Replace electric panel for circuit breakers. Replace condenser disconnects. Supply concrete pad for condensing units and incidental related work.
The work shall be located at:
Building G560
Marine Corps Base, Camp Lejeune, North Carolina
SUPERVISION
One person may fill the roles of Superintendent, Quality Control Manager, and Safety & Health Officer, if duly qualified for all three positions as defined in the project specification.