24-0708 RR462 BATHROOM MODIFICATION - REFERENCE DRAWINGS.pdf
PDF 6 MB Posted
- Attached to
- RR462 Bathroom Modification
- Solicitation number
- N4008524R2851
About this file
This document appears to be a set of reference drawings related to a federal contract opportunity for the RR462 Bathroom Modification project.
The key details are:
- The contract opportunity is solicitation number N4008524R2851, issued by the Department of the Navy Naval Facilities Engineering Command.
- Only M&R MACC Contractors listed on the General Requirements cover page may submit proposals for this project within the ROICC Camp Lejeune area of responsibility.
- The drawings contain information on the floor plans, interior elevations, plumbing, mechanical, and electrical systems for the bathroom modification work.
- The drawings include both record drawings (existing conditions) and new drawings for the proposed modifications.
No other details about the specific scope of work, pricing, award dates, or other contract terms are provided in the document. This appears to be a set of reference drawings rather than a full solicitation package.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
brando.williams.civ Text Box
PO Box 541, New Bern, NC 28563
252.636.8778 (PHONE)
252.636.8992 (FAX)
the
8-23-13
NORTH
brando.williams.civ
252.636.8992 (FAX)
the
8-23-13
NORTH
brando.williams.civ
UNIT AREA SERVED CFM ESP FAN SONES DRIVE W VOLTS PHASE TYPE REMARKS
TAG (IN.) RPM
EF-1, EF-2 TOILETS 75 0.25 700 2.3 DIRECT 50 115 1 C 1 -6
1. TYPES: C = CEILING
2. SOLID STATE SPEED CONTROL SWITCH ON FAN OR NEARBY FOR ALL DIRECT DRIVE SINGLE PHS MOTORS.
3. VERIFY FAN INLET/OUTLET SIZE, TRANSITION TO FIRST DUCT SIZE IF NECESSARY.
4. DISCONNECT SWITCH (NEMA TYPE 3R OR PLUG) BY MFGR. FOR ALL SINGLE PHASE MOTORS (U.N.O.).
5. LISTED SONES IS MAX ALLOWED. FANS MUST BE AMCA CERTIFIED FOR AIR AND SOUND.
CERTIFICATION MUST BE PROVIDED WITH SUBMITTAL.
6. INTERLOCK WITH TOILET LIGHT SWITCH.
FAN SCHEDULE
SYM TYPE USE CFM NECK OVER- DMPR FINISH FRAME REMARKS
RANGE SIZE ALL
SIZE
A-- LOUVER SUPPLY SEE PLANS RMK 5 RMK 4 NO OFF RMK 3 1-6
FACE 4-WAY & RMK 5 WHITE
BT- PERF. RETURN/ SEE PLANS RMK 7 RMK 4 NO OFF RMK 3 1-4, 7-10
EXHAUST & RMK 6 WHITE
BS- PERF. RETURN/ SEE PLANS RMK 7 RMK 4 NO OFF RMK 3 1-4, 7-10
EXHAUST & RMK 6 WHITE
C- SIDEWALL SUPPLY SEE PLANS SEE RMK 4 NO RMK 12 SEE 1-4, 11-13
PLANS PLANS
D- SIDEWALL RETURN/ SEE PLANS SEE RMK 4 NO RMK 12 SEE 1-4, 9, 12, 13
EXHAUST PLANS PLANS
REMARKS
1. USED. PAINT ALL INSIDE VISIBLE SURFACES FLAT BLACK. 8. NO NECK SIZE INDICATES NON-
2. SYMBOL EXPLANATION: DUCTED, LAY-IN PANEL.
XXX/CFM = SYMBOL, FRAME (RMK 3), NECK (RMK 5,7)/CFM 9. NOTE NOT USED.
3. FRAME TYPES: T = T-BAR 10. ALL ALUM. CONSTRUCTION (INCLUDING
S = FLUSH SURF. MTD.. E = DUCT MOUNTED: V-BEVELED BACKPAN) IF SHOWN ON PLANS.
PLASTER FRAME FOR DROP SURF. (TYPE "A" DIFFUSER) 11. VOLUME EXTRACTOR WHERE
CEILING MOUNTING. D = DROPPED FRAME SHOWN ON PLANS.
NOTE: VERIFY FRAME/CEILING COMPATIBILITY. 12. PAINT TO MATCH WALL.
4. OVERALL SIZE: LAY-IN = 2'x2', OTHER GRILLES = NECK + 2"+/-. 13. VERTICAL FRONT BLADES.
5. LOUVER FACE SUPPLY NECK SIZES
NO. ROUND CFM NO. SQUARE CFM
NK SIZE NK SIZE
A 6" 100 H 6x6 125 B 8" 175 I 9x9 280 C 10" 275 J 12x12 500 D 12" 400 K 15x15 780 E 14" 535 L 18x18 1125 F 16" 700 M 21x21 1530 G 18" 885 N 24x24 2000
NOTE: VERIFY CFM / NECK SIZE.
6. ADJUSTABLE: HORIZONTAL/VERTICAL - "PIANO HINGE" DEVICE.
7. "B" & "E" EXH/RETURN NECK SIZES ("E" = SQ. NK. ONLY)
NO. ROUND CFM NO. SQUARE CFM
NK SIZE NK SIZE
A 6" 100 G 8x8 220 B 8" 175 H 10x10 345 C 10" 275 I 12x12 500 D 12" 400 J 14x14 680 E 14" 535 K 16x16 885 F 16" 700 L 18x18 1125 NOTE: VERIFY M 22x22 1680 CFM / NECK SIZE. N 22x46 2600
GRILLE & DIFFUSER SCHEDULE
PRESCRIPTIVE ENERGY COST BUDGET
THERMAL ZONE: 3 ONSLOW COUNTY, NORTH CAROLINA
OUTDOOR DESIGN CONDITIONS (F) - WINTER: 22.6, SUMMER: 91.5/77.4 (DB/WB)
INDOOR DESIGN CONDITIONS (F) - WINTER: 70, SUMMER: 76
BUILDING HEATING LOAD - CALCULATED 52.3 MBH, INSTALLED 105 MBH
BUILDING COOLING LOAD - CALCULATED 9.8 TONS, INSTALLED 10 TONS
MECHANICAL SPACE CONDITIONING SYSTEM
DESCRIPTION OF UNITS: HIGH EFFICIENCY SPLIT SYSTEM HEAT PUMP UNITS
EQUIPMENT SCHEDULES WITH MOTORS (MECHANICAL SYSTEMS)
MOTOR HP: SPECS REQUIRE COMPLIANCE W/N.C. ENERGY CODE
NUMBER OF PHASES: SPECS REQUIRE COMPLIANCE W/N.C. ENERGY CODE
MIN. EFFICIENCY: SPECS REQUIRE COMPLIANCE W/N.C. ENERGY CODE
MOTOR TYPE: SPECS REQUIRE COMPLIANCE W/N.C. ENERGY CODE
NUMBER OF POLES: SPECS REQUIRE COMPLIANCE W/N.C. ENERGY CODE
DESIGNER STATEMENT:
TO THE BEST OF MY KNOWLEDGE AND BELIEF, THE DESIGN OF THIS
BUILDING COMPLIES WITH THE MECHANICAL SYSTEMS, SERVICE SYSTEMS
AND EQUIPMENT REQUIREMENTS OF THE N.C. ENERGY CODE.
MECHANICAL SYSTEMS, SERVICE SYSTEMS AND
EQUIPMENT METHOD OF COMPLIANCE
SPLIT SYSTEM HEAT PUMP SCHEDULE-R410a Unit Tag Nom. SEER EER CFM O.A. ESP Air Handling Unit DX Coil Performance Heating Performance Electrical Data (Outdoor Unit) Trane Approx Weight Trane Approx Weight Remarks
Tons (Min.) (Min.) Fan Motor Electric Heating Coil MCA MOCP MCA MOCP EAT MBH MBH EAT LAT HSPF COP Capacity Fan Compressor Volts Phase MCA MOCP Model of AHU Model of Heat Pump
HP Volts Phase kW Steps Volts Phase EAT LAT Ckt.1 Ckt.1 Ckt.2 Ckt.2 Total Sens. MBH@47 F No. FLA No. LRA RLA AHU (lbs.) HP (lbs.)
AH/HP-1 5 17.75 11.50 1695 330 0.7 1.0 208 1 14.4 2 208 1 70 97.2 50 50 43 45 80/67 57.0 44.4 70 98.4 9.0 3.5 52.0 1 2.8 2 128.7 23.4 208 1 31 50 TAM7A0C60H51SA 210 4TWZ0060A1 540 1-8
AH/HP-2 5 17.75 11.50 1695 330 0.7 1.0 208 1 14.4 2 208 1 70 97.2 50 50 43 45 80/67 57.0 44.4 70 98.4 9.0 3.5 52.0 1 2.8 2 128.7 23.4 208 1 31 50 TAM7A0C60H51SA 210 4TWZ0060A1 540 1-8
1. WALL MOUNTED PROGRAMMABLE T'STAT. SEE SPECS. 4. AIR HANDLING UNITS SHALL HAVE MULTIPLE CIRCUITS AS INDICATED ON THE SCHEDULE. FAN MOTOR 6. TWO-STAGE DX COOLING AND 2-STAGE DX HEATING.
2. SEER LISTED IS THE MINIMUM ACCEPTABLE COMBINED ARI RATING FOR MATCHED INDOOR & OUTDOOR UNIT. SHALL BE POWERED BY "CKT. 1". 7. VARIABLE AIR VOLUME SUPPLY AIR FAN.
3. CONTRACTOR SHALL VERIFY CLEARANCES FOR ALL EQUIPMENT PRIOR TO SUBMITTAL. 5. REFRIGERANT LINES AND ACCESSORIES PER SPECIFICATIONS AND UNIT MFG. RECOMMENDATIONS. 8. MODEL NUMBERS SUCH AS TRANE.
252.636.8992 (FAX)
the
8-23-13 brando.williams.civ
252.636.8992 (FAX)
the
8-23-13 brando.williams.civ
NORTH
252.636.8778 (PHONE)
252.636.8992 (FAX)
the brando.williams.civ
NORTH
252.636.8778 (PHONE)
252.636.8992 (FAX)
the brando.williams.civ
| 1. RR462 Floor Plan - Record Drawing |
| 2. RR462 Floor Plan - New |
| 3. RR462 Interior Elev - Record Drawing |
| 4. RR462 Int Finish Sch - Record Drawing |
| 5. RR462 Reflective Clg Plan - Record Drawing |
| 6. RR462 Plumbing Floor Plan - Record Drawing |
| 7. RR462 Plumbing Plan - New |
| 8. RR462 Plumbing Fixture Sch - Record Drawing |
| 9. RR462 Mechanical Plan - Record Drawing |
| 10. RR462 Mechanical Plan - New |
| 11. RR462 Mechanical Schedules and Legends - Record Drawing |
| 12. RR462 Mechanical Schedules and Legends - New |
| 13. RR462 Mechanical Details - Record Drawing |
| 14. RR462 Mechanical Details - New |
| 15. RR462 Electrical Symbols and Details - Record Drawing |
| 16. RR462 Electrical Lighting Plan - Record Drawing |
| 17. Electrical Lighting Floor Plan - New |
| 18. RR462 Electrical Power Plan - Record Drawing |
| 19. RR462 Electrical Power Plan - New |
File details come from the government source that posted it. Updated .