220316-01 Combined drawings.pdf
PDF 6 MB Posted
- Attached to
- District-Wide Security Upgrade #220316-01
- Solicitation number
- S-P26028-00002187
- Issued by
- Multnomah County, Oregon
About this file
This document is a set of technology drawings related to a district-wide security system upgrade project for multiple school districts in Multnomah County, Oregon, including the Portland City School District. The main scope of work includes adding security devices such as card readers, door contacts, arm/disarm keypads, and interior and exterior IP cameras to the main distribution frame (MDF) and intermediate distribution frame (IDF) rooms across the various school campuses. The project also has an alternate scope to update the paging, intercom, and clock systems with an integrated IP-based system. The project covers approximately 10 school sites, and the drawings provide detailed floorplans and technology symbols for the security system installations.
The document does not provide specific pricing terms, set asides, funding amounts, or award details. However, it indicates the project is part of a larger district-wide security upgrade initiative, and the work is to be coordinated with the district's IT personnel. The project has an expiration date of June 30, 2022, suggesting a relatively near-term timeline for completion.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET INDEX
T0.1 SYMBOL LIST, ABBREVIATIONS - TECHNOLOGY
T1.0 OVERALL FLOORPLAN - TECHNOLOGY
T1.1 ENLARGED FLOORPLANS - TECHNOLOGY
T4.0 DETAILS - TECHNOLOGY
Abbreviations
EXISTING
(E)
ABOVE FINISHED FLOOR
AFF
GEL-FILLED UNDERGROUND CABLE
ANMW
CONDUIT
C
CATEGORY
CAT
CONTRACTOR FURNISHED CONTRACTOR
INSTALLED
CFCI
CONTRACTOR FURNISHED OWNER INSTALLED
CFOI
COAXIAL
COAX
EACH
EA
FIBER OPTIC DISTRIBUTION UNIT
FDU
FOOT, FEET
FT
HANDHOLE
HH
INTERMEDIATE DISTRIBUTION FRAME
IDF
INCH, INCHES
IN
INFORMATION TECHNOLOGY
IT
LOCAL AREA NETWORK
LAN
FIBER OPTIC CONNECTOR
LC
LOW VOLTAGE
LV
MAIN DISTRIBUTION FRAME
MDF
MISCELLANEOUS
MISC
NOT APPLICABLE
N/A
NOT TO SCALE
NTS
OWNER FURNISHED, CONTRACTOR INSTALLED
OFCI
OWNER FURNISHED, OWNER INSTALLED
OFOI
OUTSIDE PLANT
OSP
PRIVATE BRANCH EXCHANGE
PBX
POWER OVER ETHERNET
POE
PAN, TILT, ZOOM
PTZ
QUANTITY
QTY
REQUEST FOR INFORMATION
RFI
ROOM
RM
FIBER OPTIC CONNECTOR
SC
TELECOMMUNICATIONS BONDING BACKBONE
TBB
TELECOMMUNICATIONS GROUNDING BUS BAR
TGB
TELEPHONE TERMINAL BOARD
TTB
TYPICAL
TYP
UNLESS OTHERWISE NOTED
UON
WITH
W/
WITHOUT
W/O
WIDE AREA NETWORK
WAN
WORK AREA OUTLET
WAO
WIRELESS ACCESS POINT
WAP
WIRELESS FIDELITY
WI-FI
WEATHERPROOF
WP
GENERAL TECHNOLOGY NOTES:
A. COMMUNICATIONS RACEWAYS, TRAYS, AND OUTLETS ARE SHOWN
DIAGRAMMATICALLY. LOCATIONS ARE APPROXIMATE UNLESS
SPECIFICALLY DIMENSIONED. FIELD COORDINATE ALL WORK WITH
OTHER TRADES.
B.
C.
D.
ALTERNATE COMMUNICATIONS OUTLET (X):
(X)
1=
STANDARD COMMUNICATIONS OUTLET WITH (1) CAT6
CABLE TO NEAREST MDF/IDF AND 1"C TO ACCESSIBLE
CEILING SPACE.
2= STANDARD COMMUNICATIONS OUTLET WITH (2) CAT6
CABLE(S) TO NEAREST MDF/IDF AND 1"C TO
ACCESSIBLE CEILING SPACE.
STANDARD COMMUNICATIONS OUTLET WITH (3) CAT6
CABLE(S) TO NEAREST MDF/IDF AND 1"C TO ACCESSIBLE
CEILING SPACE.
Equipment
2-POST EQUIPMENT RACK
4-POST EQUIPMENT RACK
DOUBLE-SIDED VERTICAL WIRE MANAGEMENT
MAJOR EQUIPMENT, CABINETS OR PANELS
Telecommunications
Reference Symbols
DETAIL NUMBER AND SHEET LOCATION
KEYED NOTES
SECTION NUMBER AND SHEET LOCATION
XXX
XXX
A
Raceways
CABLE RUNWAY, WIDTH AS INDICATED
CONDUIT AND CONDUCTORS ABOVE GRADE
CONDUIT AND CONDUCTORS BELOW GRADE OR SLAB
CONDUIT DOWN
CONDUIT SLEEVE
CONDUIT UP
CONDUIT/WIRING CONTINUATION
TELECOMMUNICATIONS VAULT
VT
TECHNOLOGY SYMBOL LIST:
C=
SINGLE GANG BOX, FLUSH IN CEILING, MOUNTED TO
TILE BRIGE WITH (1) CAT6 CABLE TO NEAREST
MDF/IDF.
TELEPHONE OUTLET WITH (1) CAT6 CABLE TO NEAREST
MDF/IDF AND 3/4" C TO ACCESSIBLE CEILING SPACE.
SECURITY CONTROL PANEL LOCATION - INSTALL ANY CONTROL
DEVICE WITHIN APPROPRIATELY SIZED LOCKABLE ENCLOSURE.
Security
CARD READER - ROUTE CABLING TO CONTROLLER LOCATED AS
INDICATED ON FLOOR PLANS - ROUTE ALL CABLING CONCEALED
IN WALL OR ABOVE CEILING.
SCP
C
ELECTRIC STRIKE - INSTALLED IN DOOR JAMB - ROUTE CABLING
TO SECURITY ENCLOSURE - CONCEAL CABLING IN WALL OR
CEILING.
DOOR CONTACT - INSTALLED IN TOP DOOR JAMB - ROUTE
CABLING TO SECURITY ENCLOSURE - CONCEAL CABLING IN WALL
OR CEILING.
REQUEST TO EXIT DEVICE - INSTALLED ABOVE DOOR - ROUTE
CABLING TO SECURITY ENCLOSURE - CONCEAL CABLING IN WALL
OR CEILING.
REX
D
ES
CEILING MOUNTED IP DOME CAMERA - ROUTE CAT6 CABLE TO
MDF/IDF RACK MOUNTED PATCH PANEL - COORDINATE WITH
DISTRICT IT FOR LOCATION IN RACK AND PATCH PANEL.
SC
CONSTRUCTION DETAILS SHOW TYPICAL INSTALLATION, UON, AND
APPLY TO ALL COMMUNICATIONS WORK INCLUDED IN THE SUMMARY OF
WORK FOR THIS PACKAGE EVEN THOUGH NOT SPECIFICALLY
REFERENCED ON THE PLAN DRAWINGS.
THE TECHNOLOGY DRAWINGS ARE PART OF A LARGER SET OF
DRAWINGS WHICH, WHEN COMPLETE, CONSISTS OF DRAWINGS LISTED
BY THE "INDEX OF DRAWINGS." PARTIAL SETS OF DRAWINGS NOT
INCLUSIVE OF ALL DISCIPLINES ARE INCOMPLETE AND SHOULD NOT BE
DISTRIBUTED OR UTILIZED.
INSTALL PULL STRINGS IN ALL CONDUITS AT THE TIME OF CONDUIT AND
CABLE INSTALLATION.
KEYPAD FOR ARM/DISARM OF INTRUSION SYSTEM
K
REVISIONS
DATE
JOB NO.
CHECKED BY
DRAWN BY
SHEET NUMBER
SHEET TITLE
100 SW Main Street
Suite 1600
Portland, OR 97204
TEL 503.382.2266
www.interfaceengineering.com
Michael Troyer
2021-0080
6/09/2021
C E
N T
E N
N I A
L
H
I G
H
S
C H
O O
L
P H
A S
E
S
E n d
P O
R T
L A
N D
O
R
06/30/22EXPIRES:
SYMBOL LIST,
ABBREVIATIONS -
TECHNOLOGY
SPL
T0.1
Scott Rose Text Box
DISTRICT-WIDE SECURITY SYSTEM UPGRADES
Scott Rose Text Box
SHEET INDEX
TECHNOLOGY SYMBOL LIST
CENTENNIAL HIGH SCHOOL PLAN - 1 SHEET
CENTENNIAL MIDDLE SCHOOL PLAN - 2 SHEETS
OLIVER SCHOOL PLAN - 1 SHEET
BUTLER CREEK - 1 SHEET
MEADOWS - 1 SHEET
PARKLANE - 1 SHEET
PATRICK LYNCH - 1 SHEET
PLEASANT VALLEY - 1 SHEET
POWELL BUTTE - 1 SHEET
0 32' 64'
SCALE: 1/32"=1'-0"
16'
1 CENTENNIAL HIGH SCHOOL OVERALL PLAN - TECHNOLOGY
IDF 1
IDF 2
IDF 3
IDF 4
IDF 6
IDF 5
T1.1
T1.1
T1.1
T1.1
T1.1
T1.1
T1.1
T1.1
T1.1
T1.1
T
SCP
SC
C
D
L
L
D
C
SC
REX
SCP
REX
LED
S C
P
SC
C
D L
NO SCOPE IN MDF
ROOM OTHER
THAN SECURITY
CABLING AND
LOCATING
CLOCK/PAGING/INTERCOM
HEADEND PER
ALTERNATE
SCOPE
LD
C
SC
S C
P
REX
REX
S C
P
SC
C
D
L
LD
C
REX
SC
SCP
S C
P
SC
C
D L
REX
ONLY SECURITY
WORK IN IDF 9
ONLY SECURITY WORK
IN IDF 10
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SCSC
SC
SC
SC
SC
SC
SC
SC
SC SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SCSC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
D
D
D
D
D
D
D
D
DD
D
D
D
D
D
D D
D
D
D
DDD
D D
D
D
D
D
D
D
D
D
D D D D D
D
D D
D
D
D
D
D
D
D D
D
D
D
D
D
D
D
D
D
D D
D
D
D
D
D
D
D
D
D
D
D
D D
1 1
SC
D
D
SC
SC
SC
SC 3
K
SC
K
K
REVISIONS
DATE
JOB NO.
CHECKED BY
DRAWN BY
SHEET NUMBER
SHEET TITLE
100 SW Main Street
Suite 1600
Portland, OR 97204
TEL 503.382.2266
www.interfaceengineering.com
Michael Troyer
2021-0080
6/09/2021
C E
N T
E N
N I A
L
H
I G
H
S
C H
O O
L
P H
A S
E n d
P O
R T
L A
N D
O
R
06/30/22EXPIRES:
OVERALL
FLOORPLAN -
TECHNOLOGY
SPL
T1.0
GENERAL SCOPE NOTES
A. THE MAIN TECHNOLOGY SCOPE FOR THIS SCHOOL:
A.A. ADD THE SECURITY DEVICES TO THE IDF ROOM AND MDF ROOM AS
INDICATED.
A.B. ADD DOOR CONTACTS AT ALL EXTERIOR DOOR LOCATIONS.
A.C. ADD ARM/DISARM KEYPAD AT MAIN AND SECONDARY ENTRANCE
LOCATIONS.
A.D. ADD CAMERAS FOR INTERNAL CIRCULATION AREA COVERAGE AND
GENERAL EXTERIOR COVERAGE.
SHEET KEYNOTES
1. EXTERIOR CORNER MOUNT MULTILENS 360 CAMERAS - COORDINATE
INSTALLATION LOCATION WITH DISTRICT PERSONNEL.
2. INTERIOR CEILING MOUNT DOME CAMERAS FOR CIRCULATION AREA
COVERAGE.
3. INTERIOR DOME CAMERA FOR ENTRY VESTIBULE.
4. EXTERIOR WALL MOUNTED CAMERA TO COVER ENTRY AREA.
5. ADD DOOR CONTACTS TO EXTERIOR DOORS - EACH ZONE OF THE
SCHOOL SHOULD ROUTE TO A CENTRALIZED LOCATION TO BE
COORDINATED WITH DISTRICT PERSONNEL,
6. THERE ARE EXISTING DOOR CONTROLS ON THE MAIN ENTRY - FIELD
VERIFICATION IS REQUIRED TO DETERMINE IF THE EXTERIOR DOORS
HAVE DOOR CONTACTS - THEY ARE TO BE ADDED IF THEY ARE NOT
EXISTING.
7. ARM/DISARM KEYPAD LOCATION.
T1.0
DN
DN
DN
DN
UP
1187 SF
SCIENCE
CLASSROOM
282 SF
WORKROOM
101 SF
STORAGE
96 SF
HALLWAY
36 SF
TOILET
36 SF
TOILET
886 SF
CLASSROOM
892 SF
CLASSROOM
892 SF
CLASSROOM
888 SF
CLASSROOM
155 SF
OFFICE
129 SF
OFFICE
100 SF
OFFICE
95 SF
HEALTH
124 SF
OFFICE
888 SF
CLASSROOM
892 SF
CLASSROOM
892 SF
CLASSROOM
888 SF
CLASSROOM
887 SF
CLASSROOM
892 SF
CLASSROOM
892 SF
CLASSROOM
892 SF
CLASSROOM
871 SF
CLASSROOM
50 SF
RISER ROOM
29 SF
TOILET
29 SF
TOILET
1188 SF
SCIENCE
CLASSROOM
1192 SF
SCIENCE
CLASSROOM
290 SF
SCIENCE
STORAGE
1468 SF
SPECIAL
EDUCATION
76 SF
VESTIBULE
102 SF
OFFICE
76 SF
TOILET
80 SF
TOILET
69 SF
TOILET
190 SF
CONFERENCE
194 SF
PRINCIPAL
63 SF
FILES
267 SF
HALLWAY
647 SF
RECEPTION
186 SF
ASSISTANT
PRINCIPAL
165 SF
ASSIST
PRINCIPAL
129 SF
EQUIP.
STORAGE
80 SF
OFFICE
271 SF
CONFERENCE
262 SF
GIRLS
88 SF
JANITORIAL
114 SF
CONFERENCE
114 SF
CONFERENCE
104 SF
STORAGE
196 SF
CIRCULATION
251 SF
BOYS
674 SF
SMALL
INSTRUCTION
329 SF
STAFF
WORKROOM
803 SF
CLASSROOM
918 SF
CLASSROOM
376 SF
BUILDING
STORAGE
902 SF
BOILER
489 SF
STORAGE
182 SF
HALLWAY
162 SF
GIRLS
163 SF
BOYS
109 SF
JANITORIAL
374 SF
STORAGE
5279 SF
MULTI-PURPOSE
ROOM
122 SF
PE OFFICE
258 SF
STORAGE
123 SF
PE OFFICE
119 SF
STORAGE
209 SF
Room
4 SF
Room
3 SF
Room
209 SF
Room
3 SF
Room
120 SF
Room
942 SF
HEALTH
751 SF
STAFF
LOUNGE
36 SF
PHONE ROOM
36 SF
PHONE ROOM
886 SF
CLASSROOM
888 SF
CLASSROOM
886 SF
CLASSROOM
67 SF
ELEVATOR
44 SF
TOILET
44 SF
TOILET
56 SF
JAN.
38 SF
ELEV. ROOM
892 SF
CLASSROOM
182 SF
BOYS
180 SF
GIRLS
410 SF
CORRIDOR
1492 SF
CIRCULATION
1197 SF
SCIENCE
ROOM
55 SF
STORAGE
56 SF
STORAGE
59 SF
VESTIBULE
6207 SF
GYM
6251 SF
GYM
246 SF
STORAGE
257 SF
STORAGE
156 SF
STORAGE
49 SF
PRAC.
52 SF
STOR.
662 SF
CLASSROOM
92 SF
STORAGE
1594 SF
LIFE SKILLS
82 SF
STORAGE
71 SF
STORAGE
198 SF
STORAGE
1392 SF
GROUP ROOM
44 SF
PRAC.
62 SF
VESTIBULE
69 SF
JAN.
162 SF
GIRLS
116 SF
BOYS
1659 SF
ART
CLASSROOM
61 SF
STORAGE
132 SF
STORAGE
78 SF
STORAGE
1574 SF
COMPUTER
CLASSROOM
134 SF
STORAGE
247 SF
GROUNDS
EQUIP.
STORAGE
1136 SF
HALLWAY
2467 SF
HALLWAY
1249 SF
CIRCULATION
4479 SF
CIRCULATION
129 SF
OFFICE
74 SF
COOLER
200 SF
OFFICE
1164 SF
KITCHEN
63 SF
TOILET
242 SF
BOYS
243 SF
GIRLS
2508 SF
CIRCULATION
312 SF
VESTIBULE
864 SF
CLASSROOM
862 SF
CLASSROOM
863 SF
CLASSROOM
929 SF
COMMONS
975 SF
CIRCULATION
38 SF
MECH.
38 SF
MECH.
155 SF
STORAGE
745 SF
CORRIDOR
59 SF
VESTIBULE
1197 SF
SCIENCE
CLASSROOM
181 SF
CIRCULATION
2385 SF
CIRCULATION
171 SF
WORKROOM
320 SF
WORKROOM
1192 SF
SCIENCE
CLASSROOM
1187 SF
SCIENCE
CLASSROOM
1271 SF
BOYS LOCKER
ROOM
1260 SF
GIRLS LOCKER
ROOM
3863 SF
MEDIA CENTER
125 SF
PE OFFICE
124 SF
PE OFFICE
982 SF
CIRCULATION
919 SF
COMMONS
864 SF
CLASSROOM
969 SF
SPECIAL
EDUCATION
154 SF
STAIR
81 SF
STORAGE
3'-9"
6'
S C
P
REX
C
D
L
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
D D D D
D
D D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D D
D
D
D
D
D
D D
D
D D
D
D
D D
D
D
D
D
D
D
D
DDD
D
D D
D
D
D D
K
K
K
1187 SF
SCIENCE
CLASSROOM
S C
P
REX
C
D
L
SC
0 32' 64'
SCALE: 1/32"=1'-0"
16'
1 OVERALL FLOORPLAN - TECHNOLOGY
REVISIONS
DATE
JOB NO.
CHECKED BY
DRAWN BY
SHEET NUMBER
SHEET TITLE
100 SW Main Street
Suite 1600
Portland, OR 97204
TEL 503.382.2266
www.interfaceengineering.com
Michael Troyer
2021-0080
6/09/2021
C E
N T
E N
N I A
L
M
I D
D L
E
S
C H
O O
L
P H
A S
E
S
E
B r o o k l y n
S t
P O
R T
L A
N D
O
R
06/30/22EXPIRES:
FIRST FLOOR
PLANS -
TECHNOLOGY
SPL
T0.1
0 32' 64'
SCALE: 1/32"=1'-0"
16'
2 ENLARGED IDF 1 FLOORPLAN - TECHNOLOGY
SHEET KEYNOTES
1. INSTALL SALTO CARD READER ON DOOR. INSTALL
ELECTRIC STRIKE AND DOOR CONTACT AND CONNECT TO
SALTO EDGE CONTROLLER WITHIN IDF ROOM.
2. INSTALL CEILING MOUNTED DOME CAMERA - ROUTE CABLE
DOWN TO PATCH PANEL IN RACK BELOW.
3. EXISTING DATA RACKS AND OVERHEAD LADDER RACK.
4. LOCATION FOR NEW SALTO EDGE CONTROLLER ON WALL.
5. NOT USED.
6. EXTERIOR CORNER MOUNT MULTILENS 360 CAMERAS -
COORDINATE INSTALLATION LOCATION WITH DISTRICT
PERSONNEL.
7. INTERIOR CEILING MOUNT DOME CAMERAS FOR
CIRCULATION AREA COVERAGE.
8. INTERIOR DOME CAMERA FOR ENTRY VESTIBULE.
9. EXTERIOR WALL MOUNTED CAMERA TO COVER ENTRY
AREA.
10. ADD DOOR CONTACTS TO EXTERIOR DOORS - EACH ZONE
OF THE SCHOOL SHOULD ROUTE TO A CENTRALIZED
LOCATION TO BE COORDINATED WITH DISTRICT
PERSONNEL,
11. THERE ARE EXISTING DOOR CONTROLS ON THE MAIN
ENTRY - FIELD VERIFICATION IS REQUIRED TO DETERMINE
IF THE EXTERIOR DOORS HAVE DOOR CONTACTS - THEY
ARE TO BE ADDED IF THEY ARE NOT EXISTING.
12. ARM/DISARM KEYPAD LOCATION.
ALTERNATE SCOPE
A. ADD ALTERNATE - UPDATE PAGING/INTERCOM/CLOCK SYSTEMS
WITH INTEGRATED SINGLE SYSTEM THAT IS IP BASED.
B. SYSTEM HEADEND WILL BE LOCATED IN THE MDF ROOM -
COORDINATE LOCATION WITH DISTRICT IT PERSONNEL.
C. ZONE CONTROLLERS WILL BE USED TO CONNECT TO THE EXISTING
PAGING SPEAKERS - FIELD COORDINATION WILL BE REQUIRED FOR
ZONE LOCATIONS.
D. THE CURRENT PAGING AND CLOCK SYSTEM HEADENDS ARE
LOCATED IN THE ADMIN AREA.
GENERAL SCOPE NOTES
A. THE MAIN TECHNOLOGY SCOPE FOR THIS SCHOOL:
A.A. ADD THE SECURITY DEVICES TO THE IDF ROOM AND MDF ROOM AS
INDICATED.
A.B. ADD DOOR CONTACTS AT ALL EXTERIOR DOOR LOCATIONS.
A.C. ADD ARM/DISARM KEYPAD AT MAIN AND SECONDARY ENTRANCE
LOCATIONS.
A.D. ADD CAMERAS FOR INTERNAL CIRCULATION AREA COVERAGE AND
GENERAL EXTERIOR COVERAGE.
T1.1
T1.1
T1.1
DN
209 SF
TEAM CENTER
209 SF
TEAM CENTER
120 SF
WORKROOM
886 SF
CLASSROOM
888 SF
CLASSROOM
67 SF
ELEVATOR
44 SF
TOILET
44 SF
TOILET
892 SF
CLASSROOM
181 SF
BOYS
180 SF
GIRLS
263 SF
CIRCULATION
1197 SF
SCIENCE
CLASSROOM
864 SF
CLASSROOM
862 SF
CLASSROOM
863 SF
CLASSROOM
38 SF
MECH.
38 SF
MECH.
886 SF
CLASSROOM
940 SF
COMMONS
935 SF
CIRCULATION
940 SF
COMMONS
1197 SF
SCIENCE
CLASSROOM
864 SF
CLASSROOM
67 SF
STAIR
124 SF
STORAGE
43 SF
HUB
155 SF
STORAGE
536 SF
MECH
200 SF
STORAGE
122 SF
STORAGE
67 SF
STAIR
119 SF
FAN ROOM
213 SF
FAN ROOM
789 SF
CIRCULATION
790 SF
CIRCULATION
74 SF
HUB ROOM
1473 SF
STORAGE
3975 SF
UPPER GYM
D
REX
L
C
SC
SCP
SCP
REX
D
D
L
C
SC
SC
REX
L
D
C
SCP
43 SF
HUB
155 SF
STORAGE
SCP
REX
D
D
L
C
SC
67 SF
ELEVATOR
44 SF
TOILET
44 SF
TOILET
263 SF
CIRCULATION
D
REX
L
C
SC
SCP
1473 SF
STORAGE
SC
REX
L
D
C
SCP
0 32' 64'
SCALE: 1/32"=1'-0"
16'
1 SECOND FLOOR OVERALL PLAN - TECHNOLOGY
0 4' 8'
SCALE: 1/4"=1'-0"
2'
2 IDF 2 ROOM - TECHNOLOGY
REVISIONS
DATE
JOB NO.
CHECKED BY
DRAWN BY
SHEET NUMBER
SHEET TITLE
100 SW Main Street
Suite 1600
Portland, OR 97204
TEL 503.382.2266
www.interfaceengineering.com
Michael Troyer
2021-0080
6/09/2021
C E
N T
E N
N I A
L
M
I D
D L
E
S
C H
O O
L
P H
A S
E
S
E
B r o o k l y n
S t
P O
R T
L A
N D
O
R
06/30/22EXPIRES:
0 4' 8'
SCALE: 1/4"=1'-0"
2'
3 IDF 3 ROOM - TECHNOLOGY
0 4' 8'
SCALE: 1/4"=1'-0"
2'
4 MDF ROOM - TECHNOLOGY
SECOND FLOOR
PLANS -
TECHNOLOGY
SPL
T1.1
SHEET KEYNOTES
1. INSTALL SALTO CARD READER ON DOOR. INSTALL
ELECTRIC STRIKE AND DOOR CONTACT AND CONNECT TO
SALTO EDGE CONTROLLER WITHIN IDF ROOM.
2. INSTALL CEILING MOUNTED DOME CAMERA - ROUTE CABLE
DOWN TO PATCH PANEL IN RACK BELOW.
3. EXISTING DATA RACKS AND OVERHEAD LADDER RACK.
4. LOCATION FOR NEW SALTO EDGE CONTROLLER ON WALL.
GENERAL SCOPE NOTES
A. THE MAIN TECHNOLOGY SCOPE FOR THIS SCHOOL IS TO ADD THE
SECURITY DEVICES TO THE IDF ROOM AND MDF ROOM AS INDICATED.
ALTERNATE SCOPE
A. ADD ALTERNATE - UPDATE PAGING/INTERCOM/CLOCK SYSTEMS
WITH INTEGRATED SINGLE SYSTEM THAT IS IP BASED.
B. SYSTEM HEADEND WILL BE LOCATED IN THE MDF ROOM -
COORDINATE LOCATION WITH DISTRICT IT PERSONNEL.
C. ZONE CONTROLLERS WILL BE USED TO CONNECT TO THE EXISTING
PAGING SPEAKERS - FIELD COORDINATION WILL BE REQUIRED FOR
ZONE LOCATIONS.
D. THE CURRENT PAGING AND CLOCK SYSTEM HEADENDS ARE
LOCATED IN THE ADMIN AREA.
T1.0
UP
DN
UP UP
DN
16'-6 93/128"
SC
S C
P
L
D
C
REX
REX
L D
C
SC
SCP
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
D
D
D
D
D
D
D D
D D
D
D
D
D
D
D
D
D
D
D
D
D
D
D D
D
D
DD
D
K
K
D
D
REX
L D
C
SC
SCP
SC
S C
P
L
D
C
REX
0 16' 32'
SCALE: 1/16"=1'-0"
8'
1 OVERALL FLOORPLAN - TECHNOLOGY
REVISIONS
DATE
JOB NO.
CHECKED BY
DRAWN BY
SHEET NUMBER
SHEET TITLE
100 SW Main Street
Suite 1600
Portland, OR 97204
TEL 503.382.2266
www.interfaceengineering.com
Michael Troyer
2021-0080
6/09/2021
O L
I V
R
L E
M E
N T
A R
Y
P H
A S
E
S
E
T a y l o r
S t
P O
R T
L A
N D
O
R
06/30/22EXPIRES:
0 2' 4'
SCALE: 1/2"=1'-0"
1'
2 MDF ROOM
0 2' 4'
SCALE: 1/2"=1'-0"
1'
4 IDF ROOM PROPOSED
FLOORPLANS -
TECHNOLOGY
SPL
T1.0
ALTERNATE SCOPE
A. ADD ALTERNATE - UPDATE PAGING/INTERCOM/CLOCK SYSTEMS
WITH INTEGRATED SINGLE SYSTEM THAT IS IP BASED.
B. SYSTEM HEADEND WILL BE LOCATED IN THE MDF ROOM -
COORDINATE LOCATION WITH DISTRICT IT PERSONNEL.
C. ZONE CONTROLLERS WILL BE USED TO CONNECT TO THE EXISTING
PAGING SPEAKERS - FIELD COORDINATION WILL BE REQUIRED FOR
ZONE LOCATIONS.
D. THE CURRENT PAGING AND CLOCK SYSTEM HEADENDS ARE
LOCATED IN THE ADMIN AREA.
SHEET KEYNOTES
GENERAL SCOPE NOTES
A. THE MAIN TECHNOLOGY SCOPE FOR THIS SCHOOL:
A.A. ADD THE SECURITY DEVICES TO THE IDF ROOM AND MDF ROOM AS
INDICATED.
A.B. ADD DOOR CONTACTS AT ALL EXTERIOR DOOR LOCATIONS.
A.C. ADD ARM/DISARM KEYPAD AT MAIN AND SECONDARY ENTRANCE
LOCATIONS.
A.D. ADD CAMERAS FOR INTERNAL CIRCULATION AREA COVERAGE AND
GENERAL EXTERIOR COVERAGE.
1. INSTALL SALTO CARD READER ON DOOR. INSTALL ELECTRIC STRIKE
AND DOOR CONTACT AND CONNECT TO SALTO EDGE CONTROLLER
WITHIN MDF/IDF ROOM.
2. INSTALL CEILING MOUNTED DOME CAMERA - ROUTE CABLE DOWN TO
PATCH PANEL IN RACK BELOW.
3. EXISTING DATA RACKS AND OVERHEAD LADDER RACK.
4. LOCATION FOR NEW SALTO EDGE CONTROLLER ON WALL.
5. EXTERIOR CORNER MOUNT MULTILENS 360 CAMERAS - COORDINATE
INSTALLATION LOCATION WITH DISTRICT PERSONNEL.
6. INTERIOR CEILING MOUNT DOME CAMERAS FOR CIRCULATION AREA
COVERAGE.
7. INTERIOR DOME CAMERA FOR ENTRY VESTIBULE.
8. EXTERIOR WALL MOUNTED CAMERA TO COVER ENTRY AREA.
9. ADD DOOR CONTACTS TO EXTERIOR DOORS - EACH ZONE OF THE
SCHOOL SHOULD ROUTE TO A CENTRALIZED LOCATION TO BE
COORDINATED WITH DISTRICT PERSONNEL,
10. THERE ARE EXISTING DOOR CONTROLS ON THE MAIN ENTRY - FIELD
VERIFICATION IS REQUIRED TO DETERMINE IF THE EXTERIOR DOORS
HAVE DOOR CONTACTS - THEY ARE TO BE ADDED IF THEY ARE NOT
11. ARM/DISARM KEYPAD LOCATION.
T1.0
IDF
JANITOR
MDF
C
E
S
D
SC
S
C
P
C
E
S
D
SC
S
C
P
R
E
X
R
E
X
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
D
D
D D
DD
D
D
D
D
D D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
K
K
IDF
JANITOR
C
E
S
D
SC
S
C
P
R
E
X
MDF
C
E
S
D
SC
S
C
P
R
E
X
0 16' 32'
SCALE: 1/16"=1'-0"
8'
1 OVERALL FLOORPLAN - TECHNOLOGY
0 2' 4'
SCALE: 1/2"=1'-0"
1'
2 IDF #1 ROOM - TECHNOLOGY
0 2' 4'
SCALE: 1/2"=1'-0"
1'
3 MDF ROOM - TECHNOLOGY
FLOORPPLANS -
TECHNOLOGY
SPL
T2.1
SHEET KEYNOTES
1. INSTALL SALTO CARD READER ON DOOR. INSTALL ELECTRIC STRIKE
AND DOOR CONTACT AND CONNECT TO SALTO EDGE CONTROLLER
WITHIN MDF/IDF ROOM.
2. INSTALL CEILING MOUNTED DOME CAMERA - ROUTE CABLE DOWN TO
PATCH PANEL IN RACK BELOW.
3. EXISTING DATA RACKS AND OVERHEAD LADDER RACK.
4. LOCATION FOR NEW SALTO EDGE CONTROLLER ON WALL.
5. INSTALL NEW SALTO CONTROLLER IN EXISTING SECURITY
ENCLOSURES WITH EXISTING EQUIPMENT.
6. EXTERIOR CORNER MOUNT MULTILENS 360 CAMERAS - COORDINATE
INSTALLATION LOCATION WITH DISTRICT PERSONNEL.
7. INTERIOR CEILING MOUNT DOME CAMERAS FOR CIRCULATION AREA
COVERAGE.
8. INTERIOR DOME CAMERA FOR ENTRY VESTIBULE.
9. EXTERIOR WALL MOUNTED CAMERA TO COVER ENTRY AREA.
10. ADD DOOR CONTACTS TO EXTERIOR DOORS - EACH ZONE OF THE
SCHOOL SHOULD ROUTE TO A CENTRALIZED LOCATION TO BE
COORDINATED WITH DISTRICT PERSONNEL,
11. THERE ARE EXISTING DOOR CONTROLS ON THE MAIN ENTRY - FIELD
VERIFICATION IS REQUIRED TO DETERMINE IF THE EXTERIOR DOORS
HAVE DOOR CONTACTS - THEY ARE TO BE ADDED IF THEY ARE NOT
EXISTING.
12. ARM/DISARM KEYPAD LOCATION.
REVISIONS
DATE
JOB NO.
CHECKED BY
DRAWN BY
SHEET NUMBER
SHEET TITLE
100 SW Main Street
Suite 1600
Portland, OR 97204
TEL 503.382.2266
www.interfaceengineering.com
Michael Troyer
2021-0080
6/09/2021
B U
T L
C
E
K
E
M E
N T
A R
Y
P H
A S
E
W
B u t l e r
R o a d
G r e s h a m
O
R
06/30/22EXPIRES:
GENERAL SCOPE NOTES
A. THE MAIN TECHNOLOGY SCOPE FOR THIS SCHOOL:
A.A. ADD THE SECURITY DEVICES TO THE IDF ROOM AND MDF ROOM AS
INDICATED.
A.B. ADD DOOR CONTACTS AT ALL EXTERIOR DOOR LOCATIONS.
A.C. ADD ARM/DISARM KEYPAD AT MAIN AND SECONDARY ENTRANCE
LOCATIONS.
A.D. ADD CAMERAS FOR INTERNAL CIRCULATION AREA COVERAGE AND
GENERAL EXTERIOR COVERAGE.
ALTERNATE SCOPE
A. ADD ALTERNATE - UPDATE PAGING/INTERCOM/CLOCK SYSTEMS
WITH INTEGRATED SINGLE SYSTEM THAT IS IP BASED.
B. SYSTEM HEADEND WILL BE LOCATED IN THE MDF ROOM -
COORDINATE LOCATION WITH DISTRICT IT PERSONNEL.
C. ZONE CONTROLLERS WILL BE USED TO CONNECT TO THE EXISTING
PAGING SPEAKERS - FIELD COORDINATION WILL BE REQUIRED FOR
ZONE LOCATIONS.
LOCATED IN THE MDF ROOM.
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM CLASSROOM CLASSROOM
CLASSROOM
CLASSROOM
REMEDIAL
READING
SPECIAL
EDUCATION
STORAGE
JANITOR STORAGE
RR - BOYSRR - GIRLS
COUNS/OFFICE
C O
U N
S E
L O
R
C O
U N
S C
O N
F E
R E
N C
E
INSTRUCTIONAL
MATERIALS
CENTER
CORRIDOR
RR - GIRLS RR - BOYS
B
O Y
S
G
I R
L S
TOILET
NURSEOFFICE
OFFICE
WAITING
OFFICE
OFFICE
WORK
ROOM
H A
L L
KINDERGARTEN
OFFICE STORAGE
J A
N I T
O R
MUSIC
TEACHER
LOUNGE
O Y
S
I R
L S
CUSTODIAL
STORAGE
DRYING SHOWER
L O
C K
E R
S
O Y
S
S T
O R
A G
E
HALL
HALL
SHOWERSDRYING
LOCKERS
RR - GIRLS
OFFICE
STORAGE
VESTIBULE
DRAMA
PLATFORM
MULTI-PURPOSE
ROOM
CORRIDOR CORRIDOR
KITCHEN
CAN WASH
KITCHEN
COAT
ROOM
KITCHEN
RR
KITCHEN
KITCHEN
COOLER
KITCHEN
FREEZER
KITCHEN
DRY
STORAGE
KITCHEN
DISHWASHING
CORRIDOR
ENTRY
CORRIDOR
CLASSROOM
CLASSROOM
SELF-CONTAINED
UNIT
(ELEM.) CLASSROOM
MEDIA
CENTER
PROCESSING
SHOP
TEACHER
WORK
CENTER
I R
L S
O Y
S
GIFTED
UNIT
SELF-CONTAINED
UNIT
(MIDDLE)
INDIVIDUAL
WORK &
SMALL
GROUPS
JANITOR
WEST
CORRIDOR
ENTRY
CORRIDOR
I R
L S
O Y
S
SPEECH
TESTING
MDF
INDIVIDUAL
WORK &
SMALL
GROUPS
(ELEM.)
EAST
T1.0
T1.0
SC
SCP
C
D
L
REX
SC
SC
SC
SC
SC
SCSC
SC
SC
SC
SC
SC
SC
SCSC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
D
D
D
D D
D
D
D
D
D
D
D
D
D
D
D
D D
D
D D
D
D
D
D D D
D D
D D D
D D
D
D
D
DD
D D
D D
D D
D D
D
D D
K
K
K
K
D D
K
MECHANICAL
VESTIBULE
S C
P
C
D
L
REX
SC
SPEECH
TESTING
MDF
INDIVIDUAL
WORK &
SMALL
GROUPS
(ELEM.)
EAST
SC
SCP
C
D
L
REX
0 32' 64'
SCALE: 1/32"=1'-0"
16'
1 OVERALL FLOORPLAN - TECHNOLOGY
0 4' 8'
SCALE: 1/4"=1'-0"
2'
2 IDF ROOM MEZZANINE - TECHNOLOGY
0 4' 8'
SCALE: 1/4"=1'-0"
2'
3 MDF ROOM - TECHNOLOGY
REVISIONS
DATE
JOB NO.
CHECKED BY
DRAWN BY
SHEET NUMBER
SHEET TITLE
100 SW Main Street
Suite 1600
Portland, OR 97204
TEL 503.382.2266
www.interfaceengineering.com
Michael Troyer
2021-0080
6/09/2021
M E
A D
O W
S
E
L E
M E
N T
A R
Y
P H
A S
E
S
E
B r o o k l y n
S t
P O
R T
L A
N D
O
R
06/30/22EXPIRES:
FLOORPLANS -
TECHNOLOGY
SPL
T1.0
SHEET KEYNOTES
ALTERNATE SCOPE
A. ADD ALTERNATE - UPDATE PAGING/INTERCOM/CLOCK SYSTEMS
WITH INTEGRATED SINGLE SYSTEM THAT IS IP BASED.
B. SYSTEM HEADEND WILL BE LOCATED IN THE MDF ROOM -
COORDINATE LOCATION WITH DISTRICT IT PERSONNEL.
C. ZONE CONTROLLERS WILL BE USED TO CONNECT TO THE EXISTING
PAGING SPEAKERS - FIELD COORDINATION WILL BE REQUIRED FOR
ZONE LOCATIONS.
D. THE CURRENT PAGING AND CLOCK SYSTEM HEADENDS ARE
LOCATED IN THE ADMIN AREA AND ARE TO BE DEMOLISHED AND
THEIR LOCATION PATCHED TO MATCH EXISTING.
GENERAL SCOPE NOTES
A. THE MAIN TECHNOLOGY SCOPE FOR THIS SCHOOL:
A.A. ADD THE SECURITY DEVICES TO THE IDF ROOM AND MDF ROOM AS
INDICATED.
A.B. ADD DOOR CONTACTS AT ALL EXTERIOR DOOR LOCATIONS.
A.C. ADD ARM/DISARM KEYPAD AT MAIN AND SECONDARY ENTRANCE
LOCATIONS.
A.D. ADD CAMERAS FOR INTERNAL CIRCULATION AREA COVERAGE AND
GENERAL EXTERIOR COVERAGE.
1. INSTALL SALTO CARD READER ON DOOR. INSTALL ELECTRIC STRIKE
AND DOOR CONTACT AND CONNECT TO SALTO EDGE CONTROLLER
WITHIN MDF/IDF ROOM.
2. INSTALL CEILING MOUNTED DOME CAMERA - ROUTE CABLE DOWN TO
PATCH PANEL IN RACK BELOW.
3. EXISTING DATA RACKS AND OVERHEAD LADDER RACK.
4. LOCATION FOR NEW SALTO EDGE CONTROLLER ON WALL.
5. EXTERIOR CORNER MOUNT MULTILENS 360 CAMERAS - COORDINATE
INSTALLATION LOCATION WITH DISTRICT PERSONNEL.
6. INTERIOR CEILING MOUNT DOME CAMERAS FOR CIRCULATION AREA
COVERAGE.
7. INTERIOR DOME CAMERA FOR ENTRY VESTIBULE.
8. EXTERIOR WALL MOUNTED CAMERA TO COVER ENTRY AREA.
9. ADD DOOR CONTACTS TO EXTERIOR DOORS - EACH ZONE OF THE
SCHOOL SHOULD ROUTE TO A CENTRALIZED LOCATION TO BE
COORDINATED WITH DISTRICT PERSONNEL,
10. THERE ARE EXISTING DOOR CONTROLS ON THE MAIN ENTRY - FIELD
VERIFICATION IS REQUIRED TO DETERMINE IF THE EXTERIOR DOORS
HAVE DOOR CONTACTS - THEY ARE TO BE ADDED IF THEY ARE NOT
UP
UP
CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM
CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM
CLASSROOMCLASSROOMCLASSROOMCLASSROOMCLASSROOMCLASSROOMCLASSROOMCLASSROOM
CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM
CORR
CORR
MULTIPURPOSE
RR GIRLS
RR GIRLS
RR BOYS
RR BOYS
JAN STOR
OFFICE
STOR
KITCHEN
TEACHERS
STOR
RR BOYS
TEACHERS
OFFICE
OFFICE
SEC/WAIT
OFFICE
WORKRM.
HALLWAY
MECH
OFFICE
VAULT
CONT PIT
TOILET
STOR
HEALTH
KITCHEN
TOILET
STOR
KITCHEN
CAN WASH
KITCHEN
DRY STOR
KITCHEN
COOLER
TEACHER
DINING
DRESS RM.
GIRLS
DRESS RM.
BOYS
STOR
HALL
HALL
JAN
TOILET
TOILET
STAGE
CONT PIT
WORKRM
CORR
CORR
TOILET
LIBRARY
COMPUTER
CORR
ENTRY
O L I V E R E L E M E N T A R Y
T1.0
T1.0
SCP
SC
C
D
L
L
SCP
SC
C
D
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC SC
SC
SC
SC
SC
D D
D
D
D
D
D
D
D
DD
DD
D
D
D
D
D D
D
D D
D D
D
D
D
D
D
K
K
9 9
CLASSROOM
STOR
RR BOYS
TEACHERS
REX
SCP
SC
C
D
L
RR BOYS
DRESS RM.
BOYS
STOR
HALL
TOILET
L
SCP
SC
C
D
REX
SC
0 32' 64'
SCALE: 1/32"=1'-0"
16'
1 OVERALL FLOORPLAN - TECHNOLOGY
REVISIONS
DATE
JOB NO.
CHECKED BY
DRAWN BY
SHEET NUMBER
SHEET TITLE
100 SW Main Street
Suite 1600
Portland, OR 97204
TEL 503.382.2266
www.interfaceengineering.com
Michael Troyer
2021-0080
6/09/2021
P A
R K
L A
N
E
M E
N T
A R
Y
P H
A S
E
S
E
M a i n
P O
R T
L A
N D
O
R
06/30/22EXPIRES:
FLOORPLANS -
TECHNOLOGY
SPL
T1.0
0 4' 8'
SCALE: 1/4"=1'-0"
2'
2 IDF #2 ROOM - PROPOSED - TECHNOLOGY
0 4' 8'
SCALE: 1/4"=1'-0"
2'
3 IDF #1 ROOM - PROPOSED - TECHNOLOGY
ALTERNATE SCOPE
A. ADD ALTERNATE - UPDATE PAGING/INTERCOM/CLOCK SYSTEMS
WITH INTEGRATED SINGLE SYSTEM THAT IS IP BASED.
B. SYSTEM HEADEND WILL BE LOCATED IN THE MDF ROOM -
COORDINATE LOCATION WITH DISTRICT IT PERSONNEL.
C. ZONE CONTROLLERS WILL BE USED TO CONNECT TO THE EXISTING
PAGING SPEAKERS - FIELD COORDINATION WILL BE REQUIRED FOR
ZONE LOCATIONS.
D. THE CURRENT PAGING AND CLOCK SYSTEM HEADENDS ARE
LOCATED IN THE ADMIN AREA.
SHEET KEYNOTES
GENERAL SCOPE NOTES
A. THE MAIN TECHNOLOGY SCOPE FOR THIS SCHOOL:
A.A. ADD THE SECURITY DEVICES TO THE IDF ROOM AND MDF ROOM AS
INDICATED.
A.B. ADD DOOR CONTACTS AT ALL EXTERIOR DOOR LOCATIONS.
A.C. ADD ARM/DISARM KEYPAD AT MAIN AND SECONDARY ENTRANCE
LOCATIONS.
A.D. ADD CAMERAS FOR INTERNAL CIRCULATION AREA COVERAGE AND
GENERAL EXTERIOR COVERAGE.
1. INSTALL SALTO CARD READER ON DOOR. INSTALL ELECTRIC STRIKE
AND DOOR CONTACT AND CONNECT TO SALTO EDGE CONTROLLER
WITHIN MDF/IDF ROOM.
2. INSTALL CEILING MOUNTED DOME CAMERA - ROUTE CABLE DOWN TO
PATCH PANEL IN RACK BELOW.
3. EXISTING DATA RACKS AND OVERHEAD LADDER RACK.
4. LOCATION FOR NEW SALTO EDGE CONTROLLER ON WALL.
5. EXTERIOR CORNER MOUNT MULTILENS 360 CAMERAS - COORDINATE
INSTALLATION LOCATION WITH DISTRICT PERSONNEL.
6. INTERIOR CEILING MOUNT DOME CAMERAS FOR CIRCULATION AREA
COVERAGE.
7. INTERIOR DOME CAMERA FOR ENTRY VESTIBULE.
8. EXTERIOR WALL MOUNTED CAMERA TO COVER ENTRY AREA.
9. ADD DOOR CONTACTS TO EXTERIOR DOORS - EACH ZONE OF THE
SCHOOL SHOULD ROUTE TO A CENTRALIZED LOCATION TO BE
COORDINATED WITH DISTRICT PERSONNEL,
10. THERE ARE EXISTING DOOR CONTROLS ON THE MAIN ENTRY - FIELD
VERIFICATION IS REQUIRED TO DETERMINE IF THE EXTERIOR DOORS
HAVE DOOR CONTACTS - THEY ARE TO BE ADDED IF THEY ARE NOT
CLASSROOMCLASSROOMCLASSROOM
CLASSROOM
STORAGE
CLASSROOMKINDERGARTEN
BOILER
ROOM
CLASSROOM
I D
F
WOMEN
MEN
M
E N
O
M E
N
C O
R R
I D
O R
CORRIDOR
LOBBY
S T
O R
A G
E
P R
I N
C I P
A L
S
O F
F I C
E
HEALTH
ROOM
RR
H A
L L
TEACHERS
ROOM
OFFICE
KINDERGARTEN CLASSROOM CLASSROOM
COMPUTER
CLASSROOM CLASSROOM
A V
S T
O R
A G
E
CLASSROOM
CLASSROOMCLASSROOMCLASSROOMCLASSROOMCLASSROOM
S T
O R
A G
E
CORRIDOR
M E
N
W O
M E
N
IDF
I R
L S
O Y
S
J A
N I T
O R
W O
M E
N
M E
N
STORAGE
MECHANICAL
MULTI-PURPOSE
ROOM
TOILET
S T
O R
A G
E
TABLE
STORAGE
C O
O L
E R
F R
E E
Z E
R
CAN WASH
DRY
STORAGE
DISH
ROOM
KITCHEN
CLASSROOM CLASSROOM
CLASSROOM
SPECIAL
EDUCATION
TOILET
CHANGING/RR
- BOYS
CHANGING/RR
- GIRLS
PLATFORM
PLATFORM
STORAGE
PLATFORM
DRESSING
RM
PLATFORM
DRESSING
RM
PLATFORM
STORAGE
AFTER-SCHOOL
T O
I L
E T
TOILET
VESTIBULE
KINDERGARTEN
WORKROOM
COUNCELOR
STORAGE
LIBRARY
CLASSROOM
T2.1
T2.1
SC
C
REX
D
ES
SCP
SC
C
REX
D
ES
SCP
SC
SC
SC
SC
SC SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
D
D D
D
D
D D
D
D
D
D
D
D D
D
D
D
D
D
D
D
D
D
D
D
SC
SC
K
K
I D
F
WOMEN
MEN
M
E N
O
M E
N
CORRIDOR
SC
C
REX
D
ES
SCP
A V
M E
N
W O
M E
N
IDF
TOILET
COUNCELOR
SC
C
REX
D
ES
SCP
FLOORPLANS -
TECHNOLOGY
SPL
T2.1
0 16' 32'
SCALE: 1/16"=1'-0"
8'
1 OVERALL FLOOR PLAN - TECHNOLOGY
0 4' 8'
SCALE: 1/4"=1'-0"
2'
ENLARGED
IDF-1 FLOORPLAN - TECHNOLOGY
0 4' 8'
SCALE: 1/4"=1'-0"
2'
ENLARGED
IDF-2 FLOORPLAN - TECHNOLOGY
REVISIONS
DATE
JOB NO.
CHECKED BY
DRAWN BY
SHEET NUMBER
SHEET TITLE
100 SW Main Street
Suite 1600
Portland, OR 97204
TEL 503.382.2266
www.interfaceengineering.com
Michael Troyer
2021-0080
6/09/2021
P A
T R
I C
K
L
Y N
C H
E
M E
N T
A R
Y
P H
A S
E t h
P
P O
R T
L A
N D
O
R
06/30/22EXPIRES:
SHEET KEYNOTES
1. INSTALL SALTO CARD READER ON DOOR. INSTALL ELECTRIC STRIKE
AND DOOR CONTACT AND CONNECT TO SALTO EDGE CONTROLLER
WITHIN MDF/IDF ROOM.
2. INSTALL CEILING MOUNTED DOME CAMERA - ROUTE CABLE DOWN TO
PATCH PANEL IN RACK BELOW.
3. EXISTING DATA RACKS AND OVERHEAD LADDER RACK.
4. LOCATION FOR NEW SALTO EDGE CONTROLLER ON WALL.
5. EXTERIOR CORNER MOUNT MULTILENS 360 CAMERAS - COORDINATE
INSTALLATION LOCATION WITH DISTRICT PERSONNEL.
6. INTERIOR CEILING MOUNT DOME CAMERAS FOR CIRCULATION AREA
COVERAGE.
7. INTERIOR DOME CAMERA FOR ENTRY VESTIBULE.
8. EXTERIOR WALL MOUNTED CAMERA TO COVER ENTRY AREA.
9. ADD DOOR CONTACTS TO EXTERIOR DOORS - EACH ZONE OF THE
SCHOOL SHOULD ROUTE TO A CENTRALIZED LOCATION TO BE
COORDINATED WITH DISTRICT PERSONNEL,
10. THERE ARE EXISTING DOOR CONTROLS ON THE MAIN ENTRY - FIELD
VERIFICATION IS REQUIRED TO DETERMINE IF THE EXTERIOR DOORS
HAVE DOOR CONTACTS - THEY ARE TO BE ADDED IF THEY ARE NOT
EXISTING.
11. ARM/DISARM KEYPAD LOCATION.
GENERAL SCOPE NOTES
A. THE MAIN TECHNOLOGY SCOPE FOR THIS SCHOOL:
A.A. ADD THE SECURITY DEVICES TO THE IDF ROOM AND MDF ROOM AS
INDICATED.
A.B. ADD DOOR CONTACTS AT ALL EXTERIOR DOOR LOCATIONS.
A.C. ADD ARM/DISARM KEYPAD AT MAIN AND SECONDARY ENTRANCE
LOCATIONS.
A.D. ADD CAMERAS FOR INTERNAL CIRCULATION AREA COVERAGE AND
GENERAL EXTERIOR COVERAGE.
ALTERNATE SCOPE
A. ADD ALTERNATE - UPDATE PAGING/INTERCOM/CLOCK SYSTEMS
WITH INTEGRATED SINGLE SYSTEM THAT IS IP BASED.
B. SYSTEM HEADEND WILL BE LOCATED IN THE MDF ROOM -
COORDINATE LOCATION WITH DISTRICT IT PERSONNEL.
C. ZONE CONTROLLERS WILL BE USED TO CONNECT TO THE EXISTING
PAGING SPEAKERS - FIELD COORDINATION WILL BE REQUIRED FOR
ZONE LOCATIONS.
LOCATED IN THE MDF ROOM.
MAILROOM
OFFICE
BOYS
NURSE
PRINCIPAL
RM2
WORKROOM
LIBRARY
GIRLS
BOYS
CUSTODIAL
MENS
WOMENS
STAFF
LOUNGE
MUSIC
CUSTODIAL
T1.0
T1.0
NO SCALE
1 OVERALL FLOORPLAN - TECHNOLOGY
CU-1
ON ROOF
FCDX-1
CU-1
ON ROOF
FCDX-1
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
D
D
D
D
K
RM 1
CUSTODIAL
REX
SCP
SC
C
D
L
GIRLS
RESTROOM
WORKROOM
RM 18
MUSIC
REX
SCP
SC
C
D
L
REVISIONS
DATE
JOB NO.
CHECKED BY
DRAWN BY
SHEET NUMBER
SHEET TITLE
100 SW Main Street
Suite 1600
Portland, OR 97204
TEL 503.382.2266
www.interfaceengineering.com
Michael Troyer
2021-0080
6/09/2021
P L
E A
S A
N T
V
A L
L E
Y
E
L E
M E
N T
A R
Y
P H
A S
E
S
E
F o s t e r
R o a d
G r e s h a m
O
R
06/30/22EXPIRES:
FLOORPLANS -
TECHNOLOGY
SPL
T1.0
0 4' 8'
SCALE: 1/4"=1'-0"
2'
2 IDF ROOM - PROPOSED - TECHNOLOGY
0 4' 8'
SCALE: 1/4"=1'-0"
2'
3 MDF ROOM - PROPOSED - TECHNOLOGY
ALTERNATE SCOPE
A. ADD ALTERNATE - UPDATE PAGING/INTERCOM/CLOCK SYSTEMS
WITH INTEGRATED SINGLE SYSTEM THAT IS IP BASED.
B. SYSTEM HEADEND WILL BE LOCATED IN THE MDF ROOM -
COORDINATE LOCATION WITH DISTRICT IT PERSONNEL.
C. ZONE CONTROLLERS WILL BE USED TO CONNECT TO THE EXISTING
PAGING SPEAKERS - FIELD COORDINATION WILL BE REQUIRED FOR
ZONE LOCATIONS.
D. THE CURRENT PAGING AND CLOCK SYSTEM HEADENDS ARE
LOCATED IN THE ADMIN AREA.
SHEET KEYNOTES
GENERAL SCOPE NOTES
A. THE MAIN TECHNOLOGY SCOPE FOR THIS SCHOOL:
A.A. ADD THE SECURITY DEVICES TO THE IDF ROOM AND MDF ROOM AS
INDICATED.
A.B. ADD DOOR CONTACTS AT ALL EXTERIOR DOOR LOCATIONS.
A.C. ADD ARM/DISARM KEYPAD AT MAIN AND SECONDARY ENTRANCE
LOCATIONS.
A.D. ADD CAMERAS FOR INTERNAL CIRCULATION AREA COVERAGE AND
GENERAL EXTERIOR COVERAGE.
A.E. THERE IS NO CAD PLAN FOR THIS SCHOOL - FIELD RESEARCH IS
REQUIRED TO DETERMINE ACTUAL COUNTS OF EXTERIOR DOORS
THAT WILL REQUIRE DOOR CONTACTS.
A.F. A PRELIMINARY SITE WALK WILL BE REQUIRED TO DETERMINE
INTERIOR AND EXTERIOR CAMERA LOCATIONS.
1. INSTALL SALTO CARD READER ON DOOR. INSTALL ELECTRIC STRIKE
AND DOOR CONTACT AND CONNECT TO SALTO EDGE CONTROLLER
WITHIN MDF/IDF ROOM.
2. INSTALL CEILING MOUNTED DOME CAMERA - ROUTE CABLE DOWN TO
PATCH PANEL IN RACK BELOW.
3. EXISTING DATA RACKS AND OVERHEAD LADDER RACK.
4. LOCATION FOR NEW SALTO EDGE CONTROLLER ON WALL.
5. EXTERIOR CORNER MOUNT MULTILENS 360 CAMERAS - COORDINATE
INSTALLATION LOCATION WITH DISTRICT PERSONNEL.
6. INTERIOR CEILING MOUNT DOME CAMERAS FOR CIRCULATION AREA
COVERAGE.
7. INTERIOR DOME CAMERA FOR ENTRY VESTIBULE.
8. EXTERIOR WALL MOUNTED CAMERA TO COVER ENTRY AREA.
9. ADD DOOR CONTACTS TO EXTERIOR DOORS - EACH ZONE OF THE
SCHOOL SHOULD ROUTE TO A CENTRALIZED LOCATION TO BE
COORDINATED WITH DISTRICT PERSONNEL,
10. THERE ARE EXISTING DOOR CONTROLS ON THE MAIN ENTRY - FIELD
VERIFICATION IS REQUIRED TO DETERMINE IF THE EXTERIOR DOORS
HAVE DOOR CONTACTS - THEY ARE TO BE ADDED IF THEY ARE NOT
CLASSROOM CLASSROOM
CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM CLASSROOM
CLASSROOM CLASSROOM CLASSROOM
CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM
CLASSROOM CLASSROOM CLASSROOM
RR BOYS RR GIRLS
RR
RR
RR RR
RR
RR BOYS RR GIRLS
RR
RR
JAN STOR
JAN
CLASSROOM
LIBRARY
MULTIPURPOSE
STAGE
DRESS RM
TEACHER RM
LOCKERS
GIRLS
LOCKERS
BOYS
JAN
STOR
RR
MECH
KITCHEN
STOR
KITCHEN
KITCHEN
COOLER
CAN WASH
STUDENT
WORKRM
TEACHER
WORKRM
OFFICE
STOR
TEACHER
WORKRM
OFFICE OFFICE
INSTRUMENT
RM
COMMONS
WORK RM
STOR
CONT PIT
STAFF
OFFICE
OFFICE
OFFICE
WAITING
OFFICE
OFFICE
HEALTH
OFFICE
PRINCIP
OFFICE
WORKRM
AFTERSCHOOL
STOR
RR
CORR
CORR
CORR
CORR
FF:
107.5
FF:
107.5
FF:
105.5
FF:
107.23
FF:
107.23
FF:
107.23
NEW PREENGINEERED METAL
BUILDING COVERED PLAY WITH
4 POLE-MOUNTED BASKETBALL
HOOPS AND ASPHALT
PAVEMENT. APPROXIMATELY
3,000 SF.
T1.0
T1.0
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SCSC SC SC
D D
D
D
D
D
DD
D
D
D
D D
D D
D
D
D
D
D
D
D
K
K
6 6
TEACHER RM
REX
C
D
L
S C
P
SC
STOR
RR
SC
S C
P
C
D
L
REX
REVISIONS
DATE
JOB NO.
CHECKED BY
DRAWN BY
SHEET NUMBER
SHEET TITLE
100 SW Main Street
Suite 1600
Portland, OR 97204
TEL 503.382.2266
www.interfaceengineering.com
Michael Troyer
2021-0080
6/09/2021
P O
W E
U T
T E
E L
E M
E N
T A
R Y
P H
A S
E t h
A v e n u e
P O
R T
L A
N D
O
R
06/30/22EXPIRES:
0 32' 64'
SCALE: 1/32"=1'-0"
16'
1 OVERALL FLOORPLAN - TECHNOLOGY
FLOORPLANS -
TECHNOLOGY
SPL
T1.0
0 4' 8'
SCALE: 1/4"=1'-0"
2'
2 IDF 1 ROOM - PROPOSED - TECHNOLOGY
0 4' 8'
SCALE: 1/4"=1'-0"
2'
3 MDF 2 ROOM - PROPOSED - TECHNOLOGY
ALTERNATE SCOPE
A. ADD ALTERNATE - UPDATE PAGING/INTERCOM/CLOCK SYSTEMS
WITH INTEGRATED SINGLE SYSTEM THAT IS IP BASED.
B. SYSTEM HEADEND WILL BE LOCATED IN THE MDF ROOM -
COORDINATE LOCATION WITH DISTRICT IT PERSONNEL.
C. ZONE CONTROLLERS WILL BE USED TO CONNECT TO THE EXISTING
PAGING SPEAKERS - FIELD COORDINATION WILL BE REQUIRED FOR
ZONE LOCATIONS.
D. THE CURRENT PAGING AND CLOCK SYSTEM HEADENDS ARE
LOCATED IN THE ADMIN AREA AND ARE TO BE DEMOLISHED.
SHEET KEYNOTES
GENERAL SCOPE NOTES
A. THE MAIN TECHNOLOGY SCOPE FOR THIS SCHOOL:
A.A. ADD THE SECURITY DEVICES TO THE IDF ROOM AND MDF ROOM AS
INDICATED.
A.B. ADD DOOR CONTACTS AT ALL EXTERIOR DOOR LOCATIONS.
A.C. ADD ARM/DISARM KEYPAD AT MAIN AND SECONDARY ENTRANCE
LOCATIONS.
A.D. ADD CAMERAS FOR INTERNAL CIRCULATION AREA COVERAGE AND
GENERAL EXTERIOR COVERAGE.
1. INSTALL SALTO CARD READER ON DOOR. INSTALL ELECTRIC STRIKE
AND DOOR CONTACT AND CONNECT TO SALTO EDGE CONTROLLER
WITHIN MDF/IDF ROOM.
2. INSTALL CEILING MOUNTED DOME CAMERA - ROUTE CABLE DOWN TO
PATCH PANEL IN RACK BELOW.
3. EXISTING DATA RACKS AND OVERHEAD LADDER RACK.
4. LOCATION FOR NEW SALTO EDGE CONTROLLER ON WALL.
5. EXTERIOR CORNER MOUNT MULTILENS 360 CAMERAS - COORDINATE
INSTALLATION LOCATION WITH DISTRICT PERSONNEL.
6. INTERIOR CEILING MOUNT DOME CAMERAS FOR CIRCULATION AREA
COVERAGE.
7. INTERIOR DOME CAMERA FOR ENTRY VESTIBULE.
8. EXTERIOR WALL MOUNTED CAMERA TO COVER ENTRY AREA.
9. ADD DOOR CONTACTS TO EXTERIOR DOORS - EACH ZONE OF THE
SCHOOL SHOULD ROUTE TO A CENTRALIZED LOCATION TO BE
COORDINATED WITH DISTRICT PERSONNEL,
10. THERE ARE EXISTING DOOR CONTROLS ON THE MAIN ENTRY - FIELD
VERIFICATION IS REQUIRED TO DETERMINE IF THE EXTERIOR DOORS
HAVE DOOR CONTACTS - THEY ARE TO BE ADDED IF THEY ARE NOT
File details come from the government source that posted it. Updated .