22031113-MDOT-SFLD-Bus Term-BID.pdf

PDF 1 MB Posted

Attached to
591/22069. SAA; MDOT/OPT - Multiple Solar Powered Facilities
Solicitation number
RFQ 171 220000000459 3
Issued by
Macomb County, Pittsford CDP, Michigan

About this file

This is a bid document and engineering design file for the Michigan Department of Transportation (MDOT) Southfield Bus Terminal Solar installation project, prepared by NOVA Consultants, Inc. The project involves the design and installation of a ground-mounted solar photovoltaic (PV) system with a capacity of 13.1 kilowatts direct current (kW DC) and 11.4 kilowatts alternating current (kW AC) at the MDOT Southfield facility located at 26991 Lahser Road, Southfield, Michigan 48033. The system will consist of 32 Jinko Solar photovoltaic modules rated at 410 watts each, one Fronius Primo 11.4 inverter, and associated electrical equipment including disconnects, grounding systems, and AC/DC connections. The engineering design progressed through multiple phases, with 50% design completion on June 1, 2022, 90% design completion on June 9, 2022, and the final bid documents issued on July 15, 2022. The design follows current Michigan Electrical Code, 2017 National Electrical Code (NEC), and all applicable local codes and standards.

The solar array utilizes a ground-mount configuration with a south-facing orientation (azimuth 180 degrees) and a 25-degree tilt angle, requiring site preparation including removal of specified trees, grass, topsoil, and sprinkler systems within the fenced array area. The system incorporates two parallel DC strings connecting to the single inverter, which includes residual current detection GFCI protection, arc fault protection certified to UL1699B, and anti-islanding protection compliant with UL1741 and IEEE 1547 standards. Electrical interconnection connects to the existing 200-ampere customer panel through a new junction box with a 60-ampere disconnect switch and fuse protection. The project requires installation of a 7-foot-high galvanized chain-link fence around the array area, a 3-gate access point at the northwest corner, grounding systems with multiple ground rods, and underground conduit routing from the array to the electrical room. Project file number is 591/22069.SAA, and project number is 22-03-1113.

View the file

Other files

File Type Posted
22031113-MDOT-Pontiac-Bus Term-BID.pdf PDF
Addendum 1 - 22069.pdf PDF
DCSpec Rev032022 V13 - 591 22069.SAA.PDF PDF
22031113-MDOT-BH-Bus Term-BID.pdf PDF
Addendum 2 - 22069.pdf PDF
Advertisment 22069.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOVA Consultants, Inc.

21580 Novi Road

Suite 300

Novi, MI 48375

Phone: (248) 347-3512

Fax: (248) 347-4152 www.novaconsultants.com

NO. DATE DESCRIPTION APPVD.

DESIGNED BY

CHECKED BY

REVISED

SHEET NUMBER

DRAWN BY

DATE

SCALE

DATE

DESCRIPTION

APPVD.

REVISED

F A

C

IL

IT

IE

S A

D M

IN

IS

T R

A T

IO

N

O

P E

R A

T

IO

N S

L A

N S

IN

G

M

IC

H

IG

A

N

O F F

IC

E O

F O

P E

R A

T

IO

N S

A D

M

IN

IS

T

R A

T

IV

E S

E R

V

IC

E S

T R

A N

S P

O R

T A

T

IO

N B

U

IL

D

IN

G

M

IC

H

IG

A N

D E

P A

R T

M E

N T

O F T

R A

N S

P O

R T

A T

IO

N

COVER SHEET

BD

JE

G-1

BD

MDOT-SOUTHFIELD

26991 LAHSER RD.

SOUTHFIELD, MI

48033

5-27-2022

6-1-2022 50% ENGINEERING

JE

6-9-2022 90% ENGINEERING

JE

7-15-2022 BID

JE

MDOT - SOUTHFIELD

BUS TERMINAL SOLAR

13.1 kW DC / 11.4 kW AC

TITLE REVNUM

I S

S U

E D

D A

T E

LIST OF

DRAWINGS

E

N G

I N

E E

R I N

G

COVER SHEETG-1 0

ONE-LINE DIAGRAME-1

SITE / PLAN

C-1

RACKING LAYOUTE-2

GROUNDING AND ELECTRICAL DETAILSE-3

PROJECT NUMBER

22-03-1113

MICHIGAN DEPARTMENT OF TRANSPORTATION

P

L

U

R I

B U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E

R E

I S

P ENI NS UL A

M

A M

O

E

N

A

M

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

STATE OF MICHIGAN

ADAM P. LACH, RA, DIRECTOR

STATE FACILITIES ADMINISTRATION

DESIGN AND CONSTRUCTION DIVISION

FILE NO. 591/22069.SAA

N G

I N

E E

R I N

G

B I D

26'-7

26'-7

10'

11'-4"

26'-7

26'-7

10'

11'-4"

GALV. TOP RAIL

GALV. POST

9 GA. GALV. KK CHAIN

LINK FABRIC, 2" MESH.

CONCRETE FOOTING

IN AUGERED HOLE.

TENSION WIRE

FINISH GRADE

NOTE:

10" AT LINE POST

15" AT TERMINAL POST

NOTES: TERMINAL POSTS INCLUDE

END, CORNER AND PULL POSTS.

ALL FASTENERS MUST BE

GALVANIZED OR BETTER.

10'-0" O.C. (MAXIMUM)

LATCH

MECHANISM

3'-0" FRAME

" Ø GALV. GATE

FRAME. (TYP.)

O

F F

R A

D E

9 GA. GALV. KK CHAIN

LINK FABRIC, 2" MESH.

NOVA Consultants, Inc.

21580 Novi Road

Suite 300

Novi, MI 48375

Phone: (248) 347-3512

Fax: (248) 347-4152 www.novaconsultants.com

NO. DATE DESCRIPTION APPVD.

DESIGNED BY

CHECKED BY

REVISED

SHEET NUMBER

DRAWN BY

DATE

SCALE

DATE

DESCRIPTION

APPVD.

REVISED

F A

C

IL

IT

IE

S A

D M

IN

IS

T R

A T

IO

N

O

P E

R A

T

IO

N S

L A

N S

IN

G

M

IC

H

IG

A

N

O F F

IC

E O

F O

P E

R A

T

IO

N S

A D

M

IN

IS

T

R A

T

IV

E S

E R

V

IC

E S

T R

A N

S P

O R

T A

T

IO

N B

U

IL

D

H

IG

A N

D E

P A

R T

M E

N T

O F T

R A

N S

P O

R T

A T

IO

N

SITE / LAYOUT

BD

JE

C-1

AS NOTED

BD

MDOT-SOUTHFIELD

26991 LAHSER RD.

SOUTHFIELD, MI

48033

5-27-2022

6-1-2022 50% ENGINEERING

JE

6-9-2022 90% ENGINEERING

JE

7-15-2022 BID

JE

SITE LAYOUT

Scale : N.T.S.

PROJECT NUMBER

22-03-1113

NORTH

SHEET GENERAL NOTES

SHEET KEY NOTES

PV SYSTEM DESCRIPTION

1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT

MICHIGAN ELECTRICAL CODE, 2017 NATIONAL ELECTRICAL CODE

(NEC), AND ALL APPLICABLE LOCAL CODES AND STANDARDS.

ARRAY TYPE:: GROUND MOUNT

ARZIMUTH:: 180°

TILT: 25°

1. 13.1 kW DC SOLAR PV ARRAY

2. TREES TO BE REMOVED.

3. TRIM TREE TO MAX. HEIGHT OF 15' AND MAX. DIAMETER OF 15'.

4. REMOVE GRASS, TOP SOIL AND SPRINKLER SYSTEM WITHIN

FENCE AREA.

FILL WITH 21AA AND COMPACT TO HAVE POSITIVE DRAINAGE

AWAY FROM THE BUILDING LEAVING 3" DOWN FROM CONCRETE

AND STRUCTURE.

PLACE WEED BARRIER (DEWITT PRO 5) AND 3" OF MDOT 17A

LIMESTONE BACK TO GRADE.

LEGEND

0 5' 10' 20' 40'

SCALE: 1" = 20'

LEGEND

NORTH

SITE / PLAN

Scale : 1" = 20'-0"

NORTH

L A

H S

D

W. 11 MILE RD.

7' HIGH GALV. CHAIN LINK FENCE

F i l e

N o

S

A A

FENCE DETAIL

Scale :

" = 1'-0"

A1

GROUND COVER DETAIL

Scale : 1" = 1'-0"

B1

3'-0" GATE, NORTHWEST

CORNER WHERE 5'

SIDEWALK ENDS.

FENCE TO ALIGN WITH CORNER

OF THE BUILDING, AS SHOWN.

DISC-A

METER / J BOX

FENCE TO ALIGN WITH CORNER

OF THE BUILDING, AS SHOWN.

GATE DETAIL

Scale :

" = 1'-0"

A2

1 2 16

1 2 16

-2

+2

-1

+1

INVERTER

MODEL: FRONIUS

JB

M

EXISTING

CUSTOMER

PANEL (200 AMP.)

EXISTING

UTILITY

INSTALLED

METER

PRIMO 11.4 - 1/240.OND

FRONIUS USA

NEW

JUNCTION

BOX

240 V. 60 A DISCONNECT

WITH 60 A FUSE

STRING 1

STRING 2

NOVA Consultants, Inc.

21580 Novi Road

Suite 300

Novi, MI 48375

Phone: (248) 347-3512

Fax: (248) 347-4152 www.novaconsultants.com

NO. DATE DESCRIPTION APPVD.

DESIGNED BY

CHECKED BY

REVISED

SHEET NUMBER

DRAWN BY

DATE

SCALE

DATE

DESCRIPTION

APPVD.

REVISED

F A

C

IL

IT

IE

S A

D M

IN

IS

T R

A T

IO

N

O

P E

R A

T

IO

N S

L A

N S

IN

G

M

IC

H

IG

A

N

O F F

IC

E O

F O

P E

R A

T

IO

N S

A D

M

IN

IS

T

R A

T

IV

E S

E R

V

IC

E S

T R

A N

S P

O R

T A

T

IO

N B

U

IL

D

H

IG

A N

D E

P A

R T

M E

N T

O F T

R A

N S

P O

R T

A T

IO

N

ONE-LINE

DIAGRAM

BD

JE

E-1

BD

MDOT SOUTHFIELD

26991 LAHSER RD.

SOUTHFIELD, MI

48033

5-27-2022

6-1-2022 50% ENGINEERING

JE

6-9-2022 90% ENGINEERING

JE

7-15-2022 BID

JE

ONE-LINE DIAGRAM

E1 Scale : None

PROJECT NUMBER

22-03-1113

SHEET GENERAL NOTES

PV SYSTEM DESCRIPTION

LEGEND

INVERTER #

1-1

STRING #

DISCONNECT SWITCH (1-LINE)

TRANSFORMER

FUSE

GROUND

PV STRING DESIGNATION

FOR TOTAL SYSTEM:

PV MODULE MODEL: JINKO SOLAR, JKM 410M-72HL-V

PV MODULE SIZE: 79.06" L X 39.45" W X 1.57" D

NUMBER OF MODULES: 32

PV MODULE PMAX: 410 W

INVERTER MODEL: FRONIUS PRIMO 11.4 - 1 / 240.OND

INVERTER WATTAGE: 11,400 W

WATTS DC PER INVERTER: 13,100 W

NUMBER OF INVERTERS: 1

NUMBER OF STRINGS: 2

DC TO AC RATIO: 1.15

TOTAL NAMEPLATE SIZE: 13.1 kW DC

11.4 kW AC

NOTE: PV SYSTEM IS 1000 V DC (MAX.)

SHEET GENERAL NOTES

SHEET KEY NOTES

1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT

MICHIGAN ELECTRICAL CODE, 2017 NATIONAL ELECTRICAL CODE

(NEC), AND ALL APPLICABLE LOCAL CODES AND STANDARDS.

2. THE INVERTERS INCLUDE RESIDUAL CURRENT DETECTION GFCI AS

PART OF THE DC GROUND FAULT DETECTION METHOD REQUIRED BY

UL 1741.

3. ARTICLE 310.15 (B)(3)(C) EXCEPTION: TYPE XHHW-2 INSULATED

CONDUCTORS SHALL NOT BE SUBJECT TO THIS AMPACITY

ADJUSTMENT PER 310.15

4. DC CONDUCTORS SHALL BE DERATED PER 310.15

5. FRONIUS INVERTERS ARE CERTIFIED UL1699B FOR ARC FAULT

PROTECTION PER SECTION 690.11

6. INVERTER INCLUDES ANTI-ISLANDING PROTECTION COMPLIANT

WITH UL1741 AND IEEE 1547 PER NEC 690.

7. PHOTOVOLTAIC SYSTEM LABLES SHALL BE INSTALLED PER NEC 2017

1. AC GROUNDING CONNECTION TO MAIN SERVICE PANEL

PROVIDES CONNECTION TO BUILDING GROUNDING ELECTRODE

SYSTEM. GROUNDING CONDUCTORS AND BONDING JUMPERS TO

BE INSTALLED TO COMPLY WITH ARTICLE 250.

2. NEW SUPPLY SIDE AC CONNECTION POWER PRODUCTION

CONDUCTORS MUST MEET NEC 690,705.12(A), AND 705.31.

EXCEPTION: WHERE THE OVERCURRENT PROTECTION FOR THE

POWER PRODUCTION SOURCE IS LOCATED MORE THAN 3M (10FT)

FROM THE POINT OF CONNECTION FOR THE ELECTRIC POWER

PRODUCTION SOURCE TO THE SERVICE, CABLE LIMITERS OR

CURRENT - LIMITED CIRCUIT BREAKERS FOR EACH UNGROUNDED

CONDUCTOR SHALL BE INSTALLED AT THE POINT WHERE THE

ELECTRIC POWER PRODUCTION CONDUCTORS ARE CONNECTED TO

THE SERVICE.

3. REFER TO CHART ON E-1 FOR CONDUIT AND WIRE SIZES.

4. INSTALL PLACARD SHOWING LOCATIONS OF DISCONNECT AND

SOLAR ARRAY.

5. INVERTERS MAXIMUM CURRENT PER MANUFACTURE'S SPEC SHEET:

47.5 A (11.4 KW INVERTER)

6. OVERCURRENT PROTECTION COMPLIES WITH NEC 705.30, 705.65

AND 240. THE 60 A OCPD IS BASED ON 47.5 X 1.25 = 60 A.

THE #6 WIRE IS BASED ON THIS VALUE.

C

A

B

D

E

(TYP.)

G

3 (TYP.)

(TYP.)

(TYP.)

47.5 A

F

F i l e

N o

S

A

8'-6" 13'-4"

26'-7

3'-3

FINISH

GRADE

FRONT (SOUTH) GROUND

POSTS (MIN. 72" BELOW

GRADE)

ANGLED

POST

PURLIN

25°

FINISH

GRADE

REAR (NORTH) GROUND

POSTS (MIN. 78" BELOW

GRADE)

ANGLED

POST

PURLIN

25°

12'

12'-0

DRIVEN POSTDRIVEN POST

ALTERNATE - POST IN 60" CONCRETE FOOTING,

WHEN TYPICAL DRIVEN POST CANNOT BE USED

DUE TO DEBRIS. INSTALL 24" DIA. SONOTUBE

24" TO GRADE.

24"

NOVA Consultants, Inc.

21580 Novi Road

Suite 300

Novi, MI 48375

Phone: (248) 347-3512

Fax: (248) 347-4152 www.novaconsultants.com

NO. DATE DESCRIPTION APPVD.

DESIGNED BY

CHECKED BY

REVISED

SHEET NUMBER

DRAWN BY

DATE

SCALE

DATE

DESCRIPTION

APPVD.

REVISED

F A

C

IL

IT

IE

S A

D M

IN

IS

T R

A T

IO

N

O

P E

R A

T

IO

N S

L A

N S

IN

G

M

IC

H

IG

A

N

O F F

IC

E O

F O

P E

R A

T

IO

N S

A D

M

IN

IS

T

R A

T

IV

E S

E R

V

IC

E S

T R

A N

S P

O R

T A

T

IO

N B

U

IL

D

H

IG

A N

D E

P A

R T

M E

N T

O F T

R A

N S

P O

R T

A T

IO

N

RACKING LAYOUT

BD

JE

E2

1/2" = 1'-0"

BD

MDOT-SOUTHFIELD

26991 LAHSER RD.

SOUTHFIELD, MI

48033

5-27-2022

6-1-2022 50% ENGINEERING

JE

6-9-2022 90% ENGINEERING

JE

7-15-2022 BID

JE

SOLAR RACK ELEVATION

A3 Scale :

" = 1'-0"

PROJECT NUMBER

22-03-1113

SOLAR RACK SECTION

B1 Scale :

" = 1'-0"

SHEET GENERAL NOTES

SHEET KEY NOTES

PV SYSTEM DESCRIPTION

1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT

MICHIGAN ELECTRICAL CODE, 2017 NATIONAL ELECTRICAL CODE

(NEC), AND ALL APPLICABLE LOCAL CODES AND STANDARDS.

ARRAY TYPE:: GROUND MOUNT

ARZIMUTH:: 180°

TILT: 25°

LEGENDLEGEND

1. SINCLAIR DESIGNS AND ENGINEERING GROUND MOUNT 2 HIGH

PORTRAIT RACKING.

(TYP.)

(TYP.)

F i l e

N o

S

A A

SOLAR RACK DETAIL

A1 Scale :

" = 1'-0"

PV MODULE (TYP.)

TO INVERTER (-)

TO INVERTER (+)

STRINGS - 1 & 2

STRING -1 (TYP.)

STRING -1 (TYP.)

#6 BARE COPPER

GROUND WIRE SECURED

TO GROUND POST

REFER TO DETAIL A3,

THIS SHEET

FINISH

GRADE

INVERTER

#6 BARE COPPER

GROUND WIRE SECURED

TO GROUND POST

REFER TO DETAIL A3,

THIS SHEET

UL LISTED CONNECTION

TO GROUND ROD, TOP OF

ROD 2"-3" BELOW GRADE

FINISH

GRADE

WEATHER HEAD

1" PVC CONDUIT TO

SECOND ARRAY

M

I N

WEATHER HEAD

UL LISTED CONNECTION

TO GROUND ROD, TOP OF

ROD 2"-3" BELOW GRADE

1" PVC CONDUIT TO

DISCONNECT-A

1" SPARE PVC CONDUIT

TO ELECT. ROOM FOR

COMMUNICATIONS.

GROUND WIRE

RACKSTAR WASHER

LAY-IN LUG RATED

FOR DIRECT BURIAL

BOLT & NUT

RACK LUG HARDWARE

GALVANIZED STEEL COPPER GALVANIZED STEEL

ALUMINUM STAINLESS OR TIN-PLATED

COPPER

STAINLESS STEEL

STAINLESS STEEL COPPER, STAINLESS OR

TIN-PLATED COPPER

STAINLESS STEEL

FINISH GRADE

M

I N

M

I N

1" PVC SCHEDULE

40 CONDUIT FOR

AC / DC POWER

INVERTER TO DISCONNECT /

SECOND ARRAY DC STRING WIRE

6" WIDE PLASTIC WITH METALLIC

CORE WARNING TAPE STATING

"BURIED ELECTRIC LINE BELOW".

SURFACE MATERIAL TO

MATCH ADJACENT.

NOVA Consultants, Inc.

21580 Novi Road

Suite 300

Novi, MI 48375

Phone: (248) 347-3512

Fax: (248) 347-4152 www.novaconsultants.com

NO. DATE DESCRIPTION APPVD.

DESIGNED BY

CHECKED BY

REVISED

SHEET NUMBER

DRAWN BY

DATE

SCALE

DATE

DESCRIPTION

APPVD.

REVISED

F A

C

IL

IT

IE

S A

D M

IN

IS

T R

A T

IO

N

O

P E

R A

T

IO

N S

L A

N S

IN

G

M

IC

H

IG

A

N

O F F

IC

E O

F O

P E

R A

T

IO

N S

A D

M

IN

IS

T

R A

T

IV

E S

E R

V

IC

E S

T R

A N

S P

O R

T A

T

IO

N B

U

IL

D

H

IG

A N

D E

P A

R T

M E

N T

O F T

R A

N S

P O

R T

A T

IO

N

GROUNDING AND

ELECTRICAL DETAILS

BD

JE

E3

AS NOTED

BD

MDOT-SOUTHFIELD

26991 LAHSER RD.

SOUTHFIELD, MI

48033

5-27-2022

6-1-2022 50% ENGINEERING

JE

6-9-2022 90% ENGINEERING

JE

7-15-2022 BID

JE

PROJECT NUMBER

22-03-1113

SHEET GENERAL NOTES

SHEET KEY NOTES

PV SYSTEM DESCRIPTION

1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT

MICHIGAN ELECTRICAL CODE, 2017 NATIONAL ELECTRICAL CODE

(NEC), AND ALL APPLICABLE LOCAL CODES AND STANDARDS.

ARRAY TYPE:: GROUND MOUNT

ARZIMUTH:: 180°

TILT: 25°

LEGENDLEGEND

Scale: 1/4" = 1'-0"

PV STRING CABLE HOOKUP ROUTING DIAGRAM

A5

Scale: NONE

GROUNDING DETAIL

A3

Scale: 3/4" = 1'-0"

GROUNDING FOR SOLAR RACKING SYSTEM

C3

1. MC4 CONNECTOR TYPICAL.

2. ROUTE LEADS CONNECTING MODULES OVER TOP OF RACK HORIZONTAL

MEMBER. INSTALL AS MUCH PV MODULE LEAD WIRE AS POSSIBLE IN CABLE

TRAY. CLIP ANY EXCESS WIRING TO MODULE FRAME WITH STAINLESS STEEL

METAL CLIPS.

3. GROUNDING ROD TO BE COPPER / COPPER CLAD AND A MIN. OF 8 FT. LONG.

Scale: 1/4" = 1'-0"

TRENCH DETAIL

A1

(TYP.)

(TYP.)

F i l e

N o

S

Sheets and Views
COVER
22031113-MDOT-SFLD-Bus Term-C-1.pdf
Sheets and Views
C-1
22031113-MDOT-SFLD-Bus Term-E-1.pdf
Sheets and Views
E-1
22031113-MDOT-SFLD-Bus Term-E-2.pdf
Sheets and Views
E-2
22031113-MDOT-SFLD-Bus Term-E-3.pdf
Sheets and Views
E-3

File details come from the government source that posted it. Updated .