This bid document pertains to a solar photovoltaic (PV) system installation project for the Michigan Department of Transportation (MDOT) at the Benton Harbor Bus Terminal facility in Benton Harbor, Michigan. The project involves the design and installation of a 20.5 kilowatt direct current (kW DC) / 20.0 kW alternating current (AC) rooftop solar array system with associated electrical infrastructure. The system includes 50 Jinko Solar photovoltaic modules (model JKM 410M-72HL-V) rated at 410 watts each, two Fronius Primo 10.0-1/240 inverters, four electrical strings, optimizers, racking systems, and all necessary electrical connections and safety equipment. The project is designated as MDOT Project Number 22-03-1113 and File Number 591/22069.SAA, with design work progressing through 50 percent engineering (June 21, 2022), 90 percent engineering (July 6, 2022), and culminating in the bid phase (July 15, 2022). The scope of work includes removal of existing atrium structures, roof preparation and decking replacement, installation of PV modules on both flat and standing seam roof sections using specified racking systems, and installation of electrical equipment located beneath roof overhangs and on the southeast wall.

The electrical system is designed in accordance with the Michigan 2015 Building Code, Michigan Electrical Code, and the 2017 National Electrical Code (NEC). The system features two separate 10 kW inverters with a total nameplate capacity of 26.6 kW DC and 20.0 kW AC, achieving a DC-to-AC ratio of 1.13. Electrical components include a 240-volt/200-ampere panelboard (PB-A), disconnect switches, 125-ampere fuses, and junction boxes configured to connect to the existing DTE utility meter and customer panel. The design incorporates residual current detection GFCI protection, arc fault protection compliant with UL1699B standards, and anti-islanding protection meeting UL1741 and IEEE 1547 requirements. The system is engineered for a maximum DC voltage of 1000 volts and includes comprehensive grounding and bonding provisions per NEC Article 250. Engineering documents produced by NOVA Consultants, Inc. include site plans, electrical site layouts, one-line diagrams, PV module attachment details, and equipment elevation specifications to guide construction and installation of the complete solar system.

View the file

Other files

File Type Posted
22031113-MDOT-Pontiac-Bus Term-BID.pdf PDF
Addendum 1 - 22069.pdf PDF
Advertisment 22069.pdf PDF
Addendum 2 - 22069.pdf PDF
DCSpec Rev032022 V13 - 591 22069.SAA.PDF PDF
22031113-MDOT-SFLD-Bus Term-BID.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOVA Consultants, Inc.

21580 Novi Road

Suite 300

Novi, MI 48375

Phone: (248) 347-3512

Fax: (248) 347-4152 www.novaconsultants.com

NO. DATE DESCRIPTION APPVD.

DESIGNED BY

CHECKED BY

REVISED

SHEET NUMBER

DRAWN BY

DATE

SCALE

DATE

DESCRIPTION

APPVD.

REVISED

F A

C

IL

IT

IE

S A

D M

IN

IS

T R

A T

IO

N

O

P E

R A

T

IO

N S

L A

N S

IN

G

M

IC

H

IG

A

N

O F F

IC

E O

F O

P E

R A

T

IO

N S

A D

M

IN

IS

T

R A

T

IV

E S

E R

V

IC

E S

T R

A N

S P

O R

T A

T

IO

N B

U

IL

D

IN

G

M

IC

H

IG

A N

D E

P A

R T

M E

N T

O F T

R A

N S

P O

R T

A T

IO

N

COVER SHEET

BD

JE

G-1

BD

2412 M-139

BENTON HARBOR

MI 49022

6-21-2022

6-21-2022 50% ENGINEERING

JE

7-6-2022 90% ENGINEERING

JE

7-15-2022 BID

JE

MDOT - BENTON HARBOR

BUS TERMINAL SOLAR

20.5 kW DC / 20.0 kW AC

TITLE REVNUM

I S

S U

E D

D A

T E

LIST OF

DRAWINGS

E

N G

I N

E E

R I N

G

COVER SHEETG-1 0

ELECTRICAL SITE PLANE-1

SITE PLAN

C-1

ONE LINE DIAGRAME-2

PV MODULE ATTACHMENTE-3

PROJECT NUMBER

22-03-1113

MICHIGAN DEPARTMENT OF TRANSPORTATION

P

L

U

R I

B U

E

S

U

N

U

M

C

I

R

C

U M

S

P

I

C

E

S

I

Q

U

E

R E

I S

P ENI NS UL A

M

A M

O

E

N

A

M

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

STATE OF MICHIGAN

ADAM P. LACH, RA, DIRECTOR

STATE FACILITIES ADMINISTRATION

DESIGN AND CONSTRUCTION DIVISION

FILE NO. 591/22069.SAA

MDOT BENTON HARBOR

EQUIPMENT ELEVATION AND DETAILSE-4

G

I N

E E

R I N

G

B I D

EXISTING

DTE METER

C

O

C

D

R

I

V

E

G

R

A

S

S

G

R

A

S

S

C

O

C

P

A

R

K

I

N

G

N

I C

K

E

R

S

O

A

V

E

M

E

G

S

T

R

I

D

U

L

E

S

E

G

S

T

R

I

D

U

L

E

E

G

S

T

R

I

D

U

L

E

E

G

S

T

R

I

D

U

L

E

S

NOVA Consultants, Inc.

21580 Novi Road

Suite 300

Novi, MI 48375

Phone: (248) 347-3512

Fax: (248) 347-4152 www.novaconsultants.com

NO. DATE DESCRIPTION APPVD.

DESIGNED BY

CHECKED BY

REVISED

SHEET NUMBER

DRAWN BY

DATE

SCALE

DATE

DESCRIPTION

APPVD.

REVISED

F A

C

IL

IT

IE

S A

D M

IN

IS

T R

A T

IO

N

O

P E

R A

T

IO

N S

L A

N S

IN

G

M

IC

H

IG

A

N

O F F

IC

E O

F O

P E

R A

T

IO

N S

A D

M

IN

IS

T

R A

T

IV

E S

E R

V

IC

E S

T R

A N

S P

O R

T A

T

IO

N B

U

IL

D

H

IG

A N

D E

P A

R T

M E

N T

O F T

R A

N S

P O

R T

A T

IO

N

SITE PLAN

BD

JE

C-1

AS NOTED

BD

2412 M-139

BENTON HARBOR

MI 49022

6-21-2022

6-21-2022 50% ENGINEERING

JE

7-6-2022 90% ENGINEERING

JE

7-15-2022 BID

JE

PROJECT NUMBER

22-03-1113

NORTH

SHEET GENERAL NOTES

SHEET KEY NOTES

PV SYSTEM DESCRIPTION

1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT

MICHIGAN 2015 BUILDING CODE, AND ALL APPLICABLE LOCAL

CODES AND STANDARDS.

ARRAY TYPE:: ROOF MOUNT

ARZIMUTH:: VARIES

TILT: VARIES

1. 20.5 kW DC SOLAR PV ARRAY

2. REMOVE AND DISPOSE OF ATRIUM, AND REPLACE ROOF DECKING

TO MATCH EXISTING.

3. ON FLAT ROOF, REMOVE AND DISPOSE OF ALL ROOFING MATERIAL

DOWN TO THE EXISTING ROOF DECKING. REPLACE ANY DAMAGED

ROOF DECKING TO MATCH EXISTING. INSTALL NEW ROOFING

MATERIALS TO MATCH EXISTING ROOFING MATERIAL (OR

EQUIVALENT).

LEGEND

0 15' 30' 60'

SCALE: 1" = 30'

LEGEND

SITE / PLAN

Scale : 1" = 30'-0"

NORTH

F i l e

N o

S

A A

MDOT BENTON HARBOR

O

S

E

G

S

T

R

I

D

U

L

E

O

S

E

G

S

T

R

I

D

U

L

E

O

S

E

G

S

T

R

I

D

U

L

E

O

S

E

G

S

T

R

I

D

U

L

E

S

NOVA Consultants, Inc.

21580 Novi Road

Suite 300

Novi, MI 48375

Phone: (248) 347-3512

Fax: (248) 347-4152 www.novaconsultants.com

NO. DATE DESCRIPTION APPVD.

DESIGNED BY

CHECKED BY

REVISED

SHEET NUMBER

DRAWN BY

DATE

SCALE

DATE

DESCRIPTION

APPVD.

REVISED

F A

C

IL

IT

IE

S A

D M

IN

IS

T R

A T

IO

N

O

P E

R A

T

IO

N S

L A

N S

IN

G

M

IC

H

IG

A

N

O F F

IC

E O

F O

P E

R A

T

IO

N S

A D

M

IN

IS

T

R A

T

IV

E S

E R

V

IC

E S

T R

A N

S P

O R

T A

T

IO

N B

U

IL

D

H

IG

A N

D E

P A

R T

M E

N T

O F T

R A

N S

P O

R T

A T

IO

N

ELECTRICAL

SITE PLAN

BD

JE

E-1

AS NOTED

BD

2412 M-139

BENTON HARBOR

MI 49022

6-21-2022

6-21-2022 50% ENGINEERING

JE

7-6-2022 90% ENGINEERING

JE

7-15-2022 BID

JE

SITE LAYOUT

Scale : NTS

PROJECT NUMBER

22-03-1113

NORTH

SHEET GENERAL NOTES

SHEET KEY NOTES

PV SYSTEM DESCRIPTION

1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT

MICHIGAN ELECTRICAL CODE, 2017 NATIONAL ELECTRICAL CODE

(NEC), AND ALL APPLICABLE LOCAL CODES AND STANDARDS.

ARRAY TYPE:: ROOF MOUNT

ARZIMUTH:: VARIES

TILT: VARIES

1. 20.5 kW DC SOLAR PV ARRAY

2. PV MODULES INSTALLED ON FLAT ROOF USING ECOLIBRIUM

ECOFOOT5D RACKING. USE SLIP SHEETS UNDER RACKING

/ BALLASTS AS REQUIRED BY ROOFING MANUFACTURE TO

MAINTAIN ROOF WARRANTY.

3. PV MODULES INSTALLED ON STANDING SEAM ROOF USING K-2

RAIL SYSTEM OR EQUIVALENT. (TYPICAL UNLESS NOTED)

4. ELECTRICAL EQUIPMENT LOCATED BENEATH ROOF OVERHANG.

5. INVERTERS LOCATED ON SOUTHEAST WALL.

6. PANELBOARD - A (PB-A)

7. DISCONNECT A (DISC-A)

8. JUNCTION BOX LOCATED BELOW DTE METER.

LEGENDLEGEND

NORTH

F i l e

N o

S

A A

MDOT BENTON HARBOR

1 2 12

1 2 13

-2

+2

-1

+1

INVERTER-1

JB

M

EXISTING

CUSTOMER

PANEL

240V / 200A

EXISTING

UTILITY

INSTALLED

METER

FRONIUS

PRIMO 10.0 - 1/240

NEW

JUNCTION

BOX

240 V. 200 A

DISCONNECT

WITH 125A FUSE

STRING 1

STRING 2

OPTOPT

OPT

OPT

OPT OPT

1 2 12

1 2 13

-2

+2

-1

+1

INVERTER-2

STRING 1

STRING 2

OPTOPT

OPT

OPT

OPT OPT

PB-A

240V / 200 A

60A

60A

125A

FRONIUS

PRIMO 10.0 - 1/240

NOVA Consultants, Inc.

21580 Novi Road

Suite 300

Novi, MI 48375

Phone: (248) 347-3512

Fax: (248) 347-4152 www.novaconsultants.com

NO. DATE DESCRIPTION APPVD.

DESIGNED BY

CHECKED BY

REVISED

SHEET NUMBER

DRAWN BY

DATE

SCALE

DATE

DESCRIPTION

APPVD.

REVISED

F A

C

IL

IT

IE

S A

D M

IN

IS

T R

A T

IO

N

O

P E

R A

T

IO

N S

L A

N S

IN

G

M

IC

H

IG

A

N

O F F

IC

E O

F O

P E

R A

T

IO

N S

A D

M

IN

IS

T

R A

T

IV

E S

E R

V

IC

E S

T R

A N

S P

O R

T A

T

IO

N B

U

IL

D

H

IG

A N

D E

P A

R T

M E

N T

O F T

R A

N S

P O

R T

A T

IO

N

ONE-LINE

DIAGRAM

BD

JE

E-2

NONE

BD

2412 M-139

BENTON HARBOR

MI 49022

6-21-2022

6-21-2022 50% ENGINEERING

JE

7-6-2022 90% ENGINEERING

JE

7-15-2022 BID

JE

ONE-LINE DIAGRAM

E1 Scale : NTS

PROJECT NUMBER

22-03-1113

SHEET GENERAL NOTES

PV SYSTEM DESCRIPTION

LEGEND

INVERTER #

1-1

STRING #

DISCONNECT SWITCH (1-LINE)

FUSE

GROUND

PV STRING DESIGNATION

FOR TOTAL SYSTEM:

PV MODULE MODEL: JINKO SOLAR, JKM 410M-72HL-V

PV MODULE SIZE: 79.06" L X 39.45" W X 1.57" D

NUMBER OF MODULES: 50

PV MODULE PMAX: 410 W

OPTIMIZERS TIGO TS4-A-O

NUMBER OF OPTIMIZERS 50

INVERTER MODEL: FRONIUS PRIMO 10.0 - 1 / 240.OND

INVERTER WATTAGE: 10,000 W

WATTS DC PER INVERTER: 13,100 W

NUMBER OF INVERTERS: 2

NUMBER OF STRINGS: 4

DC TO AC RATIO: 1.13

TOTAL NAMEPLATE SIZE: 26.6 kW DC

20.0 kW AC

NOTE: PV SYSTEM IS 1000 V DC (MAX.)

SHEET GENERAL NOTES

SHEET KEY NOTES

1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT

MICHIGAN ELECTRICAL CODE, 2017 NATIONAL ELECTRICAL CODE

(NEC), AND ALL APPLICABLE LOCAL CODES AND STANDARDS.

2. THE INVERTERS INCLUDE RESIDUAL CURRENT DETECTION GFCI AS

PART OF THE DC GROUND FAULT DETECTION METHOD REQUIRED BY

UL 1741.

3. ARTICLE 310.15 (B)(3)(C) EXCEPTION: TYPE XHHW-2 INSULATED

CONDUCTORS SHALL NOT BE SUBJECT TO THIS AMPACITY

ADJUSTMENT PER 310.15

4. DC CONDUCTORS SHALL BE DERATED PER 310.15

5. FRONIUS INVERTERS ARE CERTIFIED UL1699B FOR ARC FAULT

PROTECTION PER SECTION 690.11

6. INVERTER INCLUDES ANTI-ISLANDING PROTECTION COMPLIANT

WITH UL1741 AND IEEE 1547 PER NEC 690.

7. PHOTOVOLTAIC SYSTEM LABLES SHALL BE INSTALLED PER NEC 2017

1. AC GROUNDING CONNECTION TO MAIN SERVICE PANEL

PROVIDES CONNECTION TO BUILDING GROUNDING ELECTRODE

SYSTEM. GROUNDING CONDUCTORS AND BONDING JUMPERS TO

BE INSTALLED TO COMPLY WITH ARTICLE 250.

2. NEW SUPPLY SIDE AC CONNECTION POWER PRODUCTION

CONDUCTORS MUST MEET NEC 690,705.12(A), AND 705.31.

EXCEPTION: WHERE THE OVERCURRENT PROTECTION FOR THE

POWER PRODUCTION SOURCE IS LOCATED MORE THAN 3M (10FT)

FROM THE POINT OF CONNECTION FOR THE ELECTRIC POWER

PRODUCTION SOURCE TO THE SERVICE, CABLE LIMITERS OR

CURRENT - LIMITED CIRCUIT BREAKERS FOR EACH UNGROUNDED

CONDUCTOR SHALL BE INSTALLED AT THE POINT WHERE THE

ELECTRIC POWER PRODUCTION CONDUCTORS ARE CONNECTED TO

THE SERVICE.

3. REFER TO CHART ON E-2 FOR CONDUIT AND WIRE SIZES.

4. INSTALL PLACARD SHOWING LOCATIONS OF DISCONNECT AND

SOLAR ARRAY.

5. INVERTERS MAXIMUM CURRENT PER MANUFACTURE'S SPEC SHEET:

41.6 A (10.0 KW INVERTER)

6. OVERCURRENT PROTECTION COMPLIES WITH NEC 705.30, 705.65 AND

240. THE 60 A OCPD IS BASED ON 41.6 X 1.25 = 52 A. THE #6 WIRE IS

BASED ON THIS VALUE. THE 125A OCPD IS BASED ON THE 41.6 X 1.25

X 2 = 104 A. THE #2 WIRE IS BASED ON THIS VALUE.

A

D

F

G

(TYP.)

3 (TYP.)

(TYP.)

(TYP.)

41.6 A

F i l e

N o

S

A A

83.2 A

MDOT BENTON HARBOR

B

41.6 A

H

I

C

30'-7

3'-7

" 1'-2

14'-6"

14'-6"

NOVA Consultants, Inc.

21580 Novi Road

Suite 300

Novi, MI 48375

Phone: (248) 347-3512

Fax: (248) 347-4152 www.novaconsultants.com

NO. DATE DESCRIPTION APPVD.

DESIGNED BY

CHECKED BY

REVISED

SHEET NUMBER

DRAWN BY

DATE

SCALE

DATE

DESCRIPTION

APPVD.

REVISED

F A

C

IL

IT

IE

S A

D M

IN

IS

T R

A T

IO

N

O

P E

R A

T

IO

N S

L A

N S

IN

G

M

IC

H

IG

A

N

O F F

IC

E O

F O

P E

R A

T

IO

N S

A D

M

IN

IS

T

R A

T

IV

E S

E R

V

IC

E S

T R

A N

S P

O R

T A

T

IO

N B

U

IL

D

H

IG

A N

D E

P A

R T

M E

N T

O F T

R A

N S

P O

R T

A T

IO

N

PV MODULE

ATTACHMENT

BD

JE

E-3

AS NOTED

BD

2412 M-139

BENTON HARBOR

MI 49022

6-21-2022

6-21-2022 50% ENGINEERING

JE

7-6-2022 90% ENGINEERING

JE

7-15-2022 BID

JE

TYPICAL PV MODULE ATTACHMENT - SHAIRED RAIL SYSTEM

A1 Scale : NTS

PROJECT NUMBER

22-03-1113

TYPICAL PV MODULE ATTACHMENT - SHARED RAIL SYSTEM

B1 Scale : NTS

SHEET GENERAL NOTES

SHEET KEY NOTES

PV SYSTEM DESCRIPTION

1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT

MICHIGAN ELECTRICAL CODE, 2017 NATIONAL ELECTRICAL CODE

(NEC), AND ALL APPLICABLE LOCAL CODES AND STANDARDS.

ARRAY TYPE:: ROOF MOUNT

ARZIMUTH:: VARIES

TILT: VARIES

LEGENDLEGEND

1. ATTACHMENT ZONE PER PV MODULE MANUFACTURER ("X")

2. STANDING SEAM OF METAL ROOF

3. PV MODULE ATTACHED TO STANDING SEAM WITH CLAMP ("TARGET")

F i l e

N o

S

A A

MDOT BENTON HARBOR

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

GALVANIZED

SLOTTED STRUT

7/8" MIN

10'-0" MAX

ANCHOR TO

MASONRY WALL

WITH MINIMUM

1/4" LEAD ANCHORS

7/8" MINIMUM

REFER TO SHEET

E-2 FOR CONDUIT

SIZE

NOTE:

SUPPORT CONDUIT PER NEC2017

MINIMUM EVERY 10'-0"

D

INVERTER

NO. 2

PB-A

INVERTER

NO. 1

DISC-A

J-BOX

EXISTING EQPT.

DTE

METER

C

A

B

E

G

EXISTING 200A

PANELBOARD

INSIDE BLDG.

F

I H

NORTHEAST WALLSOUTHEAST WALL

GROUND WIRE

RACKSTAR WASHER

LAY-IN LUG RATED

FOR DIRECT BURIAL

BOLT & NUT

RACK LUG HARDWARE

GALVANIZED STEEL COPPER GALVANIZED STEEL

ALUMINUM STAINLESS OR TIN-PLATED

COPPER

STAINLESS STEEL

STAINLESS STEEL COPPER, STAINLESS OR

TIN-PLATED COPPER

STAINLESS STEEL

REFER TO SHT. E-2

FOR CONDUIT SIZE

CONDUIT SUPPORT

NOVA Consultants, Inc.

21580 Novi Road

Suite 300

Novi, MI 48375

Phone: (248) 347-3512

Fax: (248) 347-4152 www.novaconsultants.com

NO. DATE DESCRIPTION APPVD.

DESIGNED BY

CHECKED BY

REVISED

SHEET NUMBER

DRAWN BY

DATE

SCALE

DATE

DESCRIPTION

APPVD.

REVISED

F A

C

IL

IT

IE

S A

D M

IN

IS

T R

A T

IO

N

O

P E

R A

T

IO

N S

L A

N S

IN

G

M

IC

H

IG

A

N

O F F

IC

E O

F O

P E

R A

T

IO

N S

A D

M

IN

IS

T

R A

T

IV

E S

E R

V

IC

E S

T R

A N

S P

O R

T A

T

IO

N B

U

IL

D

H

IG

A N

D E

P A

R T

M E

N T

O F T

R A

N S

P O

R T

A T

IO

N

EQUIPMENT

ELEVATION

AND DETAILS

BD

JE

E-4

AS NOTED

BD

2412 M-139

BENTON HARBOR

MI 49022

6-21-2022

6-21-2022 50% ENGINEERING

JE

7-6-2022 90% ENGINEERING

JE

7-15-2022 BID

JE

PROJECT NUMBER

22-03-1113

SHEET GENERAL NOTES

SHEET KEY NOTES

PV SYSTEM DESCRIPTION

1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT

MICHIGAN ELECTRICAL CODE, 2017 NATIONAL ELECTRICAL CODE

(NEC), AND ALL APPLICABLE LOCAL CODES AND STANDARDS.

ARRAY TYPE:: ROOF MOUNT

ARZIMUTH:: VARIES

TILT: VARIES

LEGENDLEGEND

Scale: NTS

WALL CONDUIT SUPPORT DETAIL

A5

Scale: NTS

GROUNDING DETAIL

A3

Scale: NTS

EQUIPMENT ELEVATION

C3

Scale: NTS

ROOF CONDUIT SUPPORT DETAIL

A1

F i l e

N o

S

A A

MDOT BENTON HARBOR

1. LETTERS REFER TO EQUIPMENT LABELED ON CHART ON

DRAWING E-2.

2. INSTALL 1" PVC CONDUIT (SPARE) TO ELECTRICAL ROOM FOR

COMMUNICATIONS.

(TYP.)

(TYP.)

Sheets and Views
COVER
22031113-MDOT-BH-Bus Term-C-1.pdf
Sheets and Views
C-1
22031113-MDOT-BH-Bus Term-E-1.pdf
Sheets and Views
E-1
22031113-MDOT-BH-Bus Term-E-2.pdf
Sheets and Views
E-2
22031113-MDOT-BH-Bus Term-E-3.pdf
Sheets and Views
E-3
22031113-MDOT-BH-Bus Term-E-4.pdf
Sheets and Views
E-4

File details come from the government source that posted it. Updated .